KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT 8125 STEELHEAD AVE. KINGS BEACH CA SHT 1 - COVER SHEET SHT 2 - GENERAL NOTES SHT 2A - GENERAL NOTES SHT 3 - ROOF PLAN SHT 4 - DETAILS SHT 5 - DETAILS SHT 6 - DETAILS SHT 7 - DETAILS DRAWING INDEX KEY PLAN LOCATION MAP AREA OF WORK: OF SHEET: REVISION: GARLAND PHONE (800) 321-9336 / FAX (216) 641-0633 3800 EAST 91st STREET - CLEVELAND, OHIO 44105-2197 A Subsidiary of Garland Industries Design-Build Solutions, Inc. Ò GARLAND / DBS INC. DATE: CHK BY: DWG BY: GARLAND REP: PROJECT NO: KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT 8125 STEELHEAD AVE, KINGS BEACH, CA 96143 30-ES-200138 11.12.2020 TO SCM 7 1

KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT

KINGS BEACH ELEMENTARY SCHOOLROOF REPLACEMENT

8125 STEELHEAD AVE. KINGS BEACH CA

SHT 1 - COVER SHEETSHT 2 - GENERAL NOTESSHT 2A - GENERAL NOTESSHT 3 - ROOF PLANSHT 4 - DETAILSSHT 5 - DETAILSSHT 6 - DETAILSSHT 7 - DETAILS

DRAWING INDEX

KEY PLAN

LOCATION MAP

AREA OF WORK:

OFSH

EET:

REVI

SION

:

GAR

LAN

D

PHO

NE (8

00) 3

21-9

336

/ FAX

(216

) 641

-063

338

00 E

AST

91st

STR

EET

- CLE

VELA

ND, O

HIO

441

05-2

197

A S

ubsi

diar

y of

Gar

land

Indu

strie

s

Des

ign-

Bui

ld S

olut

ions

, Inc

.ÒG

AR

LAN

D /

DB

S IN

C.

DATE

:CH

K BY

:DW

G BY

:GA

RLAN

D RE

P:

PROJ

ECT

NO:

KING

S BE

ACH

ELEM

ENTA

RY S

CHOO

L ROO

F RE

PLAC

EMEN

T81

25 S

TEEL

HEAD

AVE

, KIN

GS B

EACH

, CA

9614

330

-ES-

2001

3811

.12.20

20TO

SCM

71

Page 2: KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT

TYPICAL ROOF CROSS SECTIONFASTENING INSTRUCTIONS

INSULATION BOARD FASTENING PATTERNGENERAL NOTES

NOTES

1. STORE AND HANDLE ROOFING SHEETS IN A DRY, WELL-VENTILATED, WEATHER-TITE PLACE.STORE ROLLS OF FELT AND OTHER SHEET MATERIALS ON RAISED SURFACE. STAND ALL ROLLMATERIALS ON END. COVER ROLL GOODS WITH A CANVAS TARPAULIN OR OTHERBREATHABLE MATERIAL (NOT POLYETHYLENE).

2. DO NOT LEAVE UNUSED MATERIALS ON THE ROOF WHEN ROOFING WORK IS NOT INPROGRESS UNLESS PROTECTED FROM WEATHER AND OTHER MOISTURE SOURCES.

3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE ALL MATERIAL AND EQUIPMENTON THE JOB SITE. IF ANY MATERIAL OR EQUIPMENT IS STORED ON THE ROOF, THECONTRACTOR MUST MAKE SURE THAT THE INTEGRITY OF THE DECK IS NOT COMPROMISEDAT ANY TIME.

4. DO NOT APPLY ROOFING INSULATION OR MEMBRANE TO DAMP DECK SURFACE.

5. FULLY COMPLETE ALL. MODIFIED BITUMINOUS MEMBRANE ROOFING FIELD ASSEMBLY WORKEACH DAY. PHASED CONSTRUCTION WILL NOT BE ACCEPTED.

CUSTOMER NOTE:

1. ALL OF GARLAND'S SHOP FABRICATED MATERIAL WILL BE MANUFACTURED TO THEDIMENSIONS SHOWN, UNLESS OTHERWISE NOTED.

2. IT IS ESSENTIAL THAT ANY NECESSARY CHANGES, NOTATIONS OR REQUESTEDINFORMATION BE CLEARLY NOTED ON THE SHOP DRAWINGS.

3. NO MATERIAL WILL BE CONSIDERED RELEASED FOR FABRICATION UNTIL ALL PERTINENTINFORMATION (i.e. COLOR, DIMENSIONS, MATERIAL CONFIGURATION) HAS BEEN RECEIVED.

SCOPE OF WORK NOTESTYPICAL ROOF CROSS SECTION DETAIL DESIGN CRITERIA

WIND UPLIFT REQUIREMENTSGENERAL NOTES:

1. IT IS THE ROOFING CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE THEMSELVES WITH ALL DETAILSINVOLVED IN THE ROOFING CONTRACT.

2. ALL DRAWINGS ARE GRAPHIC REPRESENTATION OF APPROXIMATE LOCATION OF EXISTING AND NEWMATERIALS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING CONDITIONS PRIOR TOCOMMENCEMENT OF WORK.

3. THE ROOFING CONTRACTOR TO PROTECT ALL ADJACENT SURFACES NOT SCHEDULED FOR WORK AND TOREPAIR ANY DAMAGED AREAS AS A RESULT OF CONTRACTOR WORK AT NO ADDITIONAL COST TO THE OWNER.

4. THE ROOFING CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN WATER TIGHTNESS AND PROVIDEPROTECTION AT ANY/ALL OPENINGS IN THE ROOF LEFT AT THE END OF EACH CONSTRUCTION DAY.

5. ALL WOOD BLOCKING SHALL BE PRESSURE TREATED.

6. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, CONDITIONS, AND QUANTITIES.

SCOPE OF WORK:

1. PROVIDE ALL LABOR, EQUIPMENT AND NON-DISTRICT SUPPLIED MATERIALS TO COMPLETE THE INSTALL OF

A NEW ROOFING SYSTEM.

2. REMOVE AND PROPERLY DISPOSE OF EXISTING ROOF SYSTEM (S) DOWN TO WOOD DECK.

3. REPLACE ALL DRY ROT WOOD DECKING

4. REMOVE AND REPLACE COPING CAP WITH KYNAR 500 COATED METAL.

5. INSTALL RED ROSIN SHEET.

6. INSTALL 2 LAYERS OF POLYISO INSULATION A TOTAL OF R-30

7. INSTALL CRICKETS TO PROVIDE PROPER FLOW TO ALL INTERNAL DRAINS.

8. MECHANICALLY FASTEN ½” SIX-SIDED ASPHALT SATURATED COVER BOARD

9. INSTALL ONE (1) PLY OF STRESSBASE 80 IN GREEN LOCK PLUS MEMBRANE ADHESIVE.

10. INSTALL STRESSPLY PLUS FR MINERAL CAP SHEET IN GREEN LOCK PLUS MEMBRANE ADHESIVE.

11. INSTALL GREEN WELD FLASHING AT ALL PIPE PENETRATIONS

12. APPLY TITLE 24 COMPLIANT COATING PYRAMIC PLUS LO

4 X 8 BOARD PATTERN

RED ROSIN PAPER

STRESSPLY PLUS FRMINERAL CAP SHEET INGREENLOCK PLUSMEMBRANE ADHESIVE

STRESSBASE 80 INGREENLOCK PLUSMEMBRANE ADHESIVE

EXISTING WOODDECK

2 LAYERS POLYISOCYANURATEINSULATION MECHANICALLYFASTENED TO DECKACCORDING TOSPECIFICATIONS.

1/2" COVERBOARDMECHANICALLY FASTENED THRUINSULATION ACCORDING TOWIND UPLIFT CALCS

1. WIND SPEED: 110 MPH

2. EXPOSURE CATEGORY: B

3. IMPORTANCE FACTOR: III

4. DESIGN ROOF HEIGHT: 15.0'

5. ROOF SLOPE: 1/2 UNITS PER 12

RESULTING WIND UPLIFT PRESSURES:

ZONE 1: 20.8 PSFZONE 2: 27.4 PSFZONE 3: 37.4 PSF

ZONES 1, 2, & 3 INSULATION BOARD FASTENER PATTERN: 12 FASTENERS PER BOARD (1:2.67 sqft)

3 SPACES @ 24"

6"

24"

12"

4'

OFSH

EET:

REVI

SION

:

GAR

LAN

D

PHO

NE (8

00) 3

21-9

336

/ FAX

(216

) 641

-063

338

00 E

AST

91st

STR

EET

- CLE

VELA

ND, O

HIO

441

05-2

197

A S

ubsi

diar

y of

Gar

land

Indu

strie

s

Des

ign-

Bui

ld S

olut

ions

, Inc

.ÒG

AR

LAN

D /

DB

S IN

C.

DATE

:CH

K BY

:DW

G BY

:GA

RLAN

D RE

P:

PROJ

ECT

NO:

KING

S BE

ACH

ELEM

ENTA

RY S

CHOO

L ROO

F RE

PLAC

EMEN

T81

25 S

TEEL

HEAD

AVE

, KIN

GS B

EACH

, CA

9614

330

-ES-

2001

3811

.12.20

20TO

SCM

72

Page 3: KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT

TYPICAL ROOF CROSS SECTIONADHESIVE INSTRUCTIONS

GENERAL NOTES

NOTES

1. STORE AND HANDLE ROOFING SHEETS IN A DRY, WELL-VENTILATED, WEATHER-TITE PLACE.STORE ROLLS OF FELT AND OTHER SHEET MATERIALS ON RAISED SURFACE. STAND ALL ROLLMATERIALS ON END. COVER ROLL GOODS WITH A CANVAS TARPAULIN OR OTHERBREATHABLE MATERIAL (NOT POLYETHYLENE).

2. DO NOT LEAVE UNUSED MATERIALS ON THE ROOF WHEN ROOFING WORK IS NOT INPROGRESS UNLESS PROTECTED FROM WEATHER AND OTHER MOISTURE SOURCES.

3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE ALL MATERIAL AND EQUIPMENTON THE JOB SITE. IF ANY MATERIAL OR EQUIPMENT IS STORED ON THE ROOF, THECONTRACTOR MUST MAKE SURE THAT THE INTEGRITY OF THE DECK IS NOT COMPROMISEDAT ANY TIME.

4. DO NOT APPLY ROOFING INSULATION OR MEMBRANE TO DAMP DECK SURFACE.

5. FULLY COMPLETE ALL. MODIFIED BITUMINOUS MEMBRANE ROOFING FIELD ASSEMBLY WORKEACH DAY. PHASED CONSTRUCTION WILL NOT BE ACCEPTED.

CUSTOMER NOTE:

1. ALL OF GARLAND'S SHOP FABRICATED MATERIAL WILL BE MANUFACTURED TO THEDIMENSIONS SHOWN, UNLESS OTHERWISE NOTED.

2. IT IS ESSENTIAL THAT ANY NECESSARY CHANGES, NOTATIONS OR REQUESTEDINFORMATION BE CLEARLY NOTED ON THE SHOP DRAWINGS.

3. NO MATERIAL WILL BE CONSIDERED RELEASED FOR FABRICATION UNTIL ALL PERTINENTINFORMATION (i.e. COLOR, DIMENSIONS, MATERIAL CONFIGURATION) HAS BEEN RECEIVED.

SCOPE OF WORK NOTESTYPICAL ROOF CROSS SECTION DETAIL DESIGN CRITERIA

WIND UPLIFT REQUIREMENTSGENERAL NOTES:

1. IT IS THE ROOFING CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE THEMSELVES WITH ALL DETAILSINVOLVED IN THE ROOFING CONTRACT.

2. ALL DRAWINGS ARE GRAPHIC REPRESENTATION OF APPROXIMATE LOCATION OF EXISTING AND NEWMATERIALS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING CONDITIONS PRIOR TOCOMMENCEMENT OF WORK.

3. THE ROOFING CONTRACTOR TO PROTECT ALL ADJACENT SURFACES NOT SCHEDULED FOR WORK AND TOREPAIR ANY DAMAGED AREAS AS A RESULT OF CONTRACTOR WORK AT NO ADDITIONAL COST TO THE OWNER.

4. THE ROOFING CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN WATER TIGHTNESS AND PROVIDEPROTECTION AT ANY/ALL OPENINGS IN THE ROOF LEFT AT THE END OF EACH CONSTRUCTION DAY.

5. ALL WOOD BLOCKING SHALL BE PRESSURE TREATED.

6. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, CONDITIONS, AND QUANTITIES.

SCOPE OF WORK:

1. TEAR OFF EXISTING ROOF TO DECK

2. CONTRACTOR SHALL IDENTIFY AREAS OF DECK WHICH NEED REPAIR OR REPLACEMENT DURING TEAROFF

3. PROPERLY CLEAN DECK

4. INSTALL (2) LAYERS OF 1” POLYISOCYANURATE INSULATION IN INSUL-LOCK HR INSULATION ADHESIVE

ACCORDING TO WIND UPLIFT CALCULATIONS. STAGGER JOINTS 4'X4' BOARDS

5. INSTALL ½” SIX-SIDED ASPHALT SATURATED COVER BOARD IN INSUL-LOCK HR ACCORDING TO WIND UPLIFT

CALCULATIONS

6. INSTALL STRESSBASE 80 BASE SHEET IN GREEN-LOCK MEMBRANE ADHESIVE

7. INSTALL STRESSPLY PLUS FR MINERAL CAP SHEET IN GREEN-LOCK PLUS MEMBRANE ADHESIVE

8. INSTALL STRESSBASE 80 BASE AND STRESSPLY MINERAL CAP FLASHING IN GREEN-LOCK PLUS FLASHING

ADHESIVE

9. INSTALL GREEN WELD FLASHING AT ALL PIPE PENETRATIONS

10. APPLY TITLE 24 COMPLIANT COATING PYRAMIC PLUS LO.

4 X 4 BOARD PATTERN

STRESSPLY PLUS FRMINERAL CAP SHEET INGREENLOCK PLUSMEMBRANE ADHESIVE

STRESSBASE 80 INGREENLOCK PLUSMEMBRANE ADHESIVE

EXISTING DECK

2 LAYERS POLYISOCYANURATEINSULATION IN INSUL-LOCK HRADHESIVE ACCORDING TOSPECIFICATIONS.

1/2" COVERBOARD ININSUL-LOCK HRACCORDING TO WINDUPLIFT CALCS

1. WIND SPEED: 110 MPH

2. EXPOSURE CATEGORY: B

3. IMPORTANCE FACTOR: III

4. DESIGN ROOF HEIGHT: 15.0'

5. ROOF SLOPE: 1/2 UNITS PER 12

RESULTING WIND UPLIFT PRESSURES:

ZONE 1: 20.8 PSFZONE 2: 27.4 PSFZONE 3: 37.4 PSF

INSULATION BOARD ADHESIVE PATTERN

TYPICAL ASCE 7 WIND PRESSURE ZONES 1, 2, & 3 INSULATION BOARDADHESIVE PATTERN: 12" OC BEADS PER BOARD

4 - 1/2" WIDE ADHESIVE RIBBONSEQUALLY SPACED AT 12" (30.5 cm)O.C. (TYP.)

ADHESIVE RIBBON ENLARGED FOR CLARITY

OFSH

EET:

REVI

SION

:

GA

RLA

ND

PH

ON

E (800) 321-9336 / F

AX

(216) 641-0633

3800 E

AS

T 91st S

TR

EE

T - C

LE

VE

LA

ND

, O

HIO

44105-2197

A S

ubsidiary of G

arland Industries

Design-B

uild S

olutions, Inc.

Ò

GA

RLA

ND

/ D

BS

INC

.

DATE

:CH

K BY

:DW

G BY

:GA

RLAN

D RE

P:

PROJ

ECT

NO:

KING

S BE

ACH

ELEM

ENTA

RY S

CHOO

L ROO

F RE

PLAC

EMEN

T81

25 S

TEEL

HEAD

AVE

, KIN

GS B

EACH

, CA

9614

330

-ES-

2001

3811

.12.20

20TO

SCM

72A

Page 4: KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT

152'-

0"

85'-1"

18'-4

"

12'-10"

210'-3"

127'-11"59'-10"

26'-1

0"

76'-2"

49'-5

"

36'-2

"

140'-6"9'-

0"TY

P.

3'-0"

TYP.

2SHT 6

2SHT 6

1SHT 4

2SHT 6

1SHT 4

2SHT 4

2SHT 4

2SHT 4 ABV

2SHT 5 BELOW

1SHT 6

1SHT 6

1SHT 6

1SHT 6

1SHT 6

3SHT 6

2SHT 4

1SHT 4

1SHT 6

WIND PRESSUREZONE DESIGNATION ZONE TYPE

ZONE 1

ZONE 2

ZONE 3

ARCH. REF.:

ROOF PLAN N

OFSH

EET:

REVI

SION

:

GAR

LAN

D

PHO

NE (8

00) 3

21-9

336

/ FAX

(216

) 641

-063

338

00 E

AST

91st

STR

EET

- CLE

VELA

ND, O

HIO

441

05-2

197

A S

ubsi

diar

y of

Gar

land

Indu

strie

s

Des

ign-

Bui

ld S

olut

ions

, Inc

.ÒG

AR

LAN

D /

DB

S IN

C.

DATE

:CH

K BY

:DW

G BY

:GA

RLAN

D RE

P:

PROJ

ECT

NO:

KING

S BE

ACH

ELEM

ENTA

RY S

CHOO

L ROO

F RE

PLAC

EMEN

T81

25 S

TEEL

HEAD

AVE

, KIN

GS B

EACH

, CA

9614

330

-ES-

2001

3811

.12.20

20TO

SCM

73

SCALE: 1" = 30'-0"

NOTE:CONTRACTOR SHALL FIELD VERIFY ALLDIMENSIONS, CONDITIONS, AND QUANTITIES.

SYMBOL LEGENDMECH UNIT CURB

ROOF HATCHSKYLIGHTROOF DRAIN

EXHAUST FAN

HEAT STACKPLUMBING STACK ROOF PENETRATIONAIR INTAKE

ROOF AREA NOT INSCOPE

Page 5: KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT

1SHT 4

TYPICAL FIELD DETAILSCALE: 1 1/2" = 1'-0"

2SHT 4

PARAPET DETAILSCALE: 1 1/2" = 1'-0"

3SHT 4

ROOF EDGE DETAILSCALE: 1 1/2" = 1'-0"

4SHT 4

AIR HANDLING CURB DETAILSCALE: 1 1/2" = 1'-0"

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

4" MIN.

2 LAYERS POLYISOCYANURATEINSULATION

1/2" COVERBOARD

EXISTING WOOD DECK

CAP FLASHING PLY9" MIN. [228mm] ON FIELD

BASE FLASHING PLY6" MIN. [152mm] ON FIELD

STRESSPLY PLUS FR MINERAL CAPSHEETSTRESSBASE 80 BASE PLY

METAL EDGE SET IN ROOF CEMENT, NAILED 3" O.C. [76MM]STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING

EXTEND PLY OVER BLOCKINGFASTEN 8" O.C. [203MM]

CONTINUOUS CLEATFASTENED 6" O.C.

[152MM]

SEALANT, REFERENCESPECIFICATION

1"MIN.

RED ROSIN PAPER

METAL COUNTERFLASHING FASTENED 8" O.C.[203MM] SCREW OR RIVET TO FLASHINGRECEIVER ONLY

CANT STRIP

1"MIN.

BASE OF UNIT EXTENDS 1/2" MINIMUM [13MM]BEYOND AND DOWN OVER TOP OF CURB

SEALING MATERIAL-MUST BECONTINUOUS ON THE PERIMETER

WOOD NAILER NOMINAL

FLASHING RECEIVER

8"MIN

UNIT MOUNTING CURB

CAP FLASHING PLY 9" MIN. [228MM] ON FIELD -TERMINATE AT TOP OF NAILER, BUT DO NOTTURN OVER TOP

BASE FLASHING PLY 6" MIN. [152MM] ONFIELD - WRAP UP AND OVER NAILERS

TERMINATION BAR FASTENED @ 8"o.c. MAX. [203mm]THROUGH BUTYL TAPE

SEALANT, REFERENCE SPECIFICATION

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

2 LAYERSPOLYISOCYANURATEINSULATION

1/2" COVERBOARD

EXISTING WOOD DECKING

STRESSPLY PLUS FR MINERALCAP SHEETSTRESSBASE 80 BASE PLY

CAP TORCH FLASHING PLY 9" MIN. [228MM] ON FIELD

BASE FLASHING PLY 6" MIN. [152MM] ON FIELD

CANT

6" CONCEALED SPLICE PLATE @ EACHJOINT

COPING COVER X 10'-0"SLOPE PER SPECIFICATION

16 GA. ANCHOR CHAIR

(4) FASTENERS PER ANCHOR CHAIR

SA HIGH TEMP UNDERLAYMENT

2" MIN 2" MIN

V.I.F.

2 LAYERSPOLYISOCYANURATEINSULATION

1/2" COVERBOARD

EXISTING WOOD DECKING

STRESSPLY PLUS FR MINERALCAP SHEETSTRESSBASE 80 BASE PLY

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

RED ROSIN PAPER

RED ROSIN PAPER

RED ROSIN PAPER

STRESSPLY PLUS FRMINERAL CAP SHEET INGREENLOCK PLUSMEMBRANE ADHESIVE

STRESSBASE 80 BASE PLY INGREENLOCK PLUSMEMBRANE ADHESIVE

EXISTING WOODDECK

2 LAYERS POLYISOCYANURATEINSULATION MECHANICALLYFASTENED TO DECKACCORDING TOSPECIFICATIONS.

1/2" COVERBOARDMECHANICALLY FASTENED THRUINSULATION ACCORDING TOWIND UPLIFT CALCS

OFSH

EET:

REVI

SION

:

GAR

LAN

D

PHO

NE (8

00) 3

21-9

336

/ FAX

(216

) 641

-063

338

00 E

AST

91st

STR

EET

- CLE

VELA

ND, O

HIO

441

05-2

197

A S

ubsi

diar

y of

Gar

land

Indu

strie

s

Des

ign-

Bui

ld S

olut

ions

, Inc

.ÒG

AR

LAN

D /

DB

S IN

C.

DATE

:CH

K BY

:DW

G BY

:GA

RLAN

D RE

P:

PROJ

ECT

NO:

KING

S BE

ACH

ELEM

ENTA

RY S

CHOO

L ROO

F RE

PLAC

EMEN

T81

25 S

TEEL

HEAD

AVE

, KIN

GS B

EACH

, CA

9614

330

-ES-

2001

3811

.12.20

20TO

SCM

74

Page 6: KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT

1SHT 5

ROOF HATCH DETAILSCALE: 1 1/2" = 1'-0"

2SHT 5

REGLET MOUNTED COUNTERFLASHING DETAILSCALE: 1 1/2" = 1'-0"

3SHT 5

ROOF DRAIN DETAILSCALE: 1 1/2" = 1'-0"

4SHT 5

PLUMBING STACK DETAILSCALE: 1 1/2" = 1'-0"

4" MIN.[102mm]

12" MIN.[305mm]

ROLL DOWN FLASHING 1" MIN [25MM]DOWN INTO PIPE

PLUMBING VENT STACK

SET SOFT METAL FLANGEIN MASTIC, PRIME FLANGEBEFORE STRIPPING

CAP FLASHING PLY 9"MIN. [228MM] ON FIELD

BASE FLASHING PLY 6" MIN. [152MM] ONFIELD

SEALANT, REFERENCESPECIFICATION

ROOF DRAIN

CAP FLASHING PLY9" MIN. [228mm] ON FIELD

BASE FLASHING PLY6" MIN. [152mm] ON FIELD

SOFT METAL FLASHING (30" MIN.) SET IN MASTIC,WRAPPED DOWN 2" MIN., PRIME TOP SURFACE

LEADER

SEALANT, REFERENCE SPECIFICATION

COUNTERFLASHING

TERMINATION BAR FASTENED @ 8"o.c. MAX. [203mm]THROUGH BUTYL TAPE(MIN. 1.5" EMBEDMENT)

CAP FLASHING PLY9" MIN. [228mm] ON FIELD

BASE FLASHING PLY6" MIN. [152mm] ON FIELD

CANT STRIP

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

SEALANT, REFERENCE SPECIFICATION

EXPANSION FASTENER

8" MIN[203MM]

SLOPE= 12:12

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, ANDINSULATION/COVER BOARD TYPE AND ATTACHMENTMETHOD.

DRAIN BOWL & CLAMP

CONNECTION HUB

2 LAYERS POLYISOCYANURATEINSULATION

1/2" COVERBOARD

EXISTING WOOD DECK

STRESSPLY PLUS FR MINERAL CAPSHEET

STRESSBASE 80 BASE PLY

RED ROSIN PAPER

2 LAYERS POLYISOCYANURATEINSULATION

1/2" COVERBOARD

EXISTING WOOD DECK

STRESSPLY PLUS FR MINERAL CAPSHEET

STRESSBASE 80 BASE PLY

RED ROSIN PAPER

1/2" COVERBOARD

STRESSPLY PLUS FR MINERAL CAP SHEETSTRESSBASE 80 BASE PLY

INSULATION, FIT TIGHT TO DRAIN

RED ROSIN PAPER

EXISTING WOOD DECK

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

TERMINATION BAR FASTENED @ 8"o.c. MAX. [203mm]THROUGH BUTYL TAPE(MIN. 1.5" EMBEDMENT)

CAP FLASHING PLY9" MIN. [228mm] ON FIELDBASE FLASHING PLY6" MIN. [152mm] ON FIELD

CANT STRIP

SEALANT, REFERENCE SPECIFICATION

8" MIN[203MM]

EXISTING ROOF HATCH

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

2 LAYERS POLYISOCYANURATEINSULATION

1/2" COVERBOARD

EXISTING WOOD DECKING

STRESSPLY PLUS FR MINERALCAP SHEET

STRESSBASE 80 BASE PLY

NEW COUNTERFLASHING. 1/8" S.S. RIVET(COLOR TO MATCH) @ 12" O.C.

RED ROSIN PAPER

OFSH

EET:

REVI

SION

:

GAR

LAN

D

PHO

NE (8

00) 3

21-9

336

/ FAX

(216

) 641

-063

338

00 E

AST

91st

STR

EET

- CLE

VELA

ND, O

HIO

441

05-2

197

A S

ubsi

diar

y of

Gar

land

Indu

strie

s

Des

ign-

Bui

ld S

olut

ions

, Inc

.ÒG

AR

LAN

D /

DB

S IN

C.

DATE

:CH

K BY

:DW

G BY

:GA

RLAN

D RE

P:

PROJ

ECT

NO:

KING

S BE

ACH

ELEM

ENTA

RY S

CHOO

L ROO

F RE

PLAC

EMEN

T81

25 S

TEEL

HEAD

AVE

, KIN

GS B

EACH

, CA

9614

330

-ES-

2001

3811

.12.20

20TO

SCM

75

Page 7: KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT

1

SHT 6

SURFACE MOUNTED COUNTERFLASHINGSCALE: 1 1/2" = 1'-0"

2

SHT 6

TYPICAL FIELD DETAIL - METAL DECKSCALE: 1 1/2" = 1'-0"

3

SHT 6

PLUMBING STACK DETAILSCALE: 1 1/2" = 1'-0"

4

SHT 6

AIR HANDLING UNIT CURB DETAILSCALE: 1 1/2" = 1'-0"

SEALANT, REFERENCE SPECIFICATION

COUNTERFLASHING FASTENED @ 8"o.c. [203mm]MAX. THROUGH BUTYL TAPE(MIN. 1.5" EMBEDMENT)

SEALANT, REFERENCE SPECIFICATIONTERMINATION BAR FASTENED @ 8"o.c. MAX. [203mm]THROUGH BUTYL TAPE

CAP FLASHING PLY9" MIN. [228mm] ON FIELD

BASE FLASHING PLY6" MIN. [152mm] ON FIELD

CANT STRIP

NOTE:REFERENCE SPECIFICATION FORSURFACING, MEMBRANE ADHESIVE TYPE,AND INSULATION/COVER BOARD TYPE ANDATTACHMENT METHOD.

8" MIN[203MM]

2 LAYERS POLYISOCYANURATEINSULATION

1/2" COVERBOARD

EXISTING WOOD DECK

STRESSPLY PLUS FRMINERAL CAP SHEET

STRESSBASE 80 BASE PLY

RED ROSIN PAPER

STRESSPLY PLUS FRMINERAL CAP SHEET INGREENLOCK PLUSMEMBRANE ADHESIVE

STRESSBASE 80 INGREENLOCK PLUSMEMBRANE ADHESIVE

EXISTING DECK

2 LAYERS POLYISOCYANURATEINSULATION IN INSUL-LOCK HRADHESIVE ACCORDING TOSPECIFICATIONS.

1/2" COVERBOARD ININSUL-LOCK HRACCORDING TO WINDUPLIFT CALCS

4" MIN.[102mm]

12" MIN.[305mm]

ROLL DOWN FLASHING 1" MIN [25MM]DOWN INTO PIPE

PLUMBING VENT STACK

SET SOFT METAL FLANGE INMASTIC, PRIME FLANGEBEFORE STRIPPING

CAP FLASHING PLY 9"MIN. [228MM] ON FIELD

BASE FLASHING PLY 6" MIN. [152MM] ONFIELD

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

SEALANT, REFERENCESPECIFICATION

METAL COUNTERFLASHING FASTENED 8" O.C.[203MM] SCREW OR RIVET TO FLASHINGRECEIVER ONLY

CANT STRIP

1"MIN.

BASE OF UNIT EXTENDS 1/2" MINIMUM [13MM]BEYOND AND DOWN OVER TOP OF CURB

SEALING MATERIAL-MUST BECONTINUOUS ON THE PERIMETER

WOOD NAILER NOMINAL

FLASHING RECEIVER

8"MIN

UNIT MOUNTING CURB

CAP FLASHING PLY 9" MIN. [228MM] ON FIELD

BASE FLASHING PLY 6" MIN. [152MM] ON FIELD

TERMINATION BAR FASTENED @ 8"o.c. MAX. [203mm]THROUGH BUTYL TAPE

SEALANT, REFERENCE SPECIFICATION

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

STRESSPLY PLUS FR MINERAL CAP SHEET

STRESSBASE 80 BASE PLY

1/2" COVERBOARD

2 LAYERS POLYISOCYANURATE INSULATION

EXISTING DECK

STRESSPLY PLUS FR MINERAL CAP SHEET

STRESSBASE 80 BASE PLY

1/2" COVERBOARD

2 LAYERS POLYISOCYANURATE INSULATION

EXISTING DECK

OFSH

EET:

REVI

SION

:

GA

RLA

ND

PH

ON

E (800) 321-9336 / F

AX

(216) 641-0633

3800 E

AS

T 91st S

TR

EE

T - C

LE

VE

LA

ND

, O

HIO

44105-2197

A S

ubsidiary of G

arland Industries

Design-B

uild S

olutions, Inc.

Ò

GA

RLA

ND

/ D

BS

INC

.

DATE

:CH

K BY

:DW

G BY

:GA

RLAN

D RE

P:

PROJ

ECT

NO:

KING

S BE

ACH

ELEM

ENTA

RY S

CHOO

L ROO

F RE

PLAC

EMEN

T81

25 S

TEEL

HEAD

AVE

, KIN

GS B

EACH

, CA

9614

330

-ES-

2001

3811

.12.20

20TO

SCM

76

Page 8: KINGS BEACH ELEMENTARY SCHOOL ROOF REPLACEMENT

1SHT 7

DRIP EDGE DETAILSCALE: 1 1/2" = 1'-0"

2SHT 7

SURFACE MOUNTED COUNTERFLASHING DETAILSCALE: 1 1/2" = 1'-0"

3SHT 7

PARAPET COPING CAP DETAILSCALE: 1 1/2" = 1'-0"

4SHT 7

REGLET MOUNTED COUNTERFLASHING DETAILSCALE: 1 1/2" = 1'-0"

SEALANT, REFERENCE SPECIFICATION

COUNTERFLASHING FASTENED @ 8"o.c. [203mm]MAX. THROUGH BUTYL TAPE(MIN. 1.5" EMBEDMENT)

SEALANT, REFERENCE SPECIFICATIONTERMINATION BAR FASTENED @ 8"o.c. MAX. [203mm]THROUGH BUTYL TAPE

CAP FLASHING PLY9" MIN. [228mm] ON FIELD

BASE FLASHING PLY6" MIN. [152mm] ON FIELD

CANT STRIP8" MIN

[203MM]

4" MIN.

CAP FLASHING PLY9" MIN. [228mm] ON FIELD

BASE FLASHING PLY6" MIN. [152mm] ON FIELD

METAL EDGE SET IN ROOF CEMENT, NAILED 3" O.C. [76MM]STAGGERED, PRIME METAL FLANGE PRIOR TO STRIPPING

EXTEND PLY OVER BLOCKINGFASTEN 8" O.C. [203MM]

CONTINUOUS CLEATFASTENED 6" O.C.

[152MM]

SEALANT, REFERENCESPECIFICATION

SEALANT, REFERENCE SPECIFICATION

COUNTERFLASHING

TERMINATION BAR FASTENED @ 8"o.c. MAX. [203mm]THROUGH BUTYL TAPE(MIN. 1.5" EMBEDMENT)

CAP FLASHING PLY9" MIN. [228mm] ON FIELD

BASE FLASHING PLY6" MIN. [152mm] ON FIELD

CANT STRIP

SEALANT, REFERENCE SPECIFICATION

EXPANSION FASTENER

8" MIN[203MM]

1"MIN.

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.

CAP TORCH FLASHING PLY 9" MIN. [228MM] ON FIELD

BASE FLASHING PLY 6" MIN. [152MM] ON FIELD

CANT

SA HIGH TEMP UNDERLAYMENT

2" MIN

V.I.F.

NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD. 6" CONCEALED SPLICE PLATE @ EACH

JOINT

COPING COVER X 10'-0"SLOPE PER SPECIFICATION

16 GA. ANCHOR CHAIR

(4) FASTENERS PER ANCHOR CHAIR

2" MIN

24" MAX

STRESSPLY PLUS FR MINERAL CAP SHEET

STRESSBASE 80 BASE PLY

1/2" COVERBOARD

2 LAYERS POLYISOCYANURATE INSULATION

EXISTING DECK

STRESSPLY PLUS FR MINERAL CAP SHEET

STRESSBASE 80 BASE PLY

1/2" COVERBOARD

2 LAYERS POLYISOCYANURATE INSULATION

EXISTING DECK

STRESSPLY PLUS FR MINERAL CAP SHEET

STRESSBASE 80 BASE PLY

1/2" COVERBOARD

2 LAYERS POLYISOCYANURATE INSULATION

EXISTING DECK

STRESSPLY PLUS FR MINERAL CAP SHEET

STRESSBASE 80 BASE PLY

1/2" COVERBOARD

2 LAYERS POLYISOCYANURATE INSULATION

EXISTING DECK

OFSH

EET:

REVI

SION

:

GAR

LAN

D

PHO

NE (8

00) 3

21-9

336

/ FAX

(216

) 641

-063

338

00 E

AST

91st

STR

EET

- CLE

VELA

ND, O

HIO

441

05-2

197

A S

ubsi

diar

y of

Gar

land

Indu

strie

s

Des

ign-

Bui

ld S

olut

ions

, Inc

.ÒG

AR

LAN

D /

DB

S IN

C.

DATE

:CH

K BY

:DW

G BY

:GA

RLAN

D RE

P:

PROJ

ECT

NO:

KING

S BE

ACH

ELEM

ENTA

RY S

CHOO

L ROO

F RE

PLAC

EMEN

T81

25 S

TEEL

HEAD

AVE

, KIN

GS B

EACH

, CA

9614

330

-ES-

2001

3811

.12.20

20TO

SCM

77