KiK-UCEP Hasemuddin School.
Plot # 07, Road # 05, Block # BSat Mosjid Housing, Beribandh, Mohammadpur, Dhaka-1207
AUTOMATIC FIRE ALARM WITHADDRESSABLE DETECTION SYSTEM
FIRE SAFETY DESIGN
TECHNIC ENGINEERING
HOUSE # 09, ROAD # 03, NIKUNJO-2,
KHILKHET DHAKA-1229
E-mail:[email protected]
1 2
FF
E
D
A
C
B
1
3 4 5 6 7 8
E
D
32 4 5 6 7
A
C
B
8
FACTORY NAMEDRAWING TITLE DATE & PAGE NO.
7th January 2018A
REV.CONSULTANT NAME CHECKED BYDESIGNED BY
Addressable Fire Detection &Alarm System
SEAL & SIGNATURE
Engr. Md. Arif Hossain
B.Sc in EEE
HOUSE # 09, ROAD # 03, NIKUNJO-2,
KHILKHET DHAKA-1229
E-mail:[email protected]
KiK-UCEP Hasemuddin School.Plot # 07, Road # 05, Block # B
Sat Mosjid Housing, Beribandh, Mohammadpur,Dhaka-1207
Engr.Md. Ibrahim Khalil
B.Sc in EEE
TE/UCEP/FDS/O1
GENERAL NOTE:
System: Automatic Fire Alarm with Addressable Detection System
Standard: NFPA 72, National Fire Alarm and Signaling Code, 2013
Hazard Group: Moderate Hazard Class-2
Product Brand: Advanced Electronics Ltd. (UL- 864 Certifaied)
Control Pannel:
2-Loop Analog Addressable Control Panel with Trouble
Alarm Notification
Model : Model: AX-CTL-4 (Intertek Listed)
(Control Panel need to install in the Fire Command Station)
Addressable Smoke Sensor (Detector):
Model: 55000-650AEL (UL Listed)
Addressable Multi Sensor (Detector):
Model: 55000-886AEL (UL Listed)
Addressable Heat Sensor (Detector):
Model :Model: 55000-450AEL (Intertek Listed)
Sensor (Detector) Base:
Model : 45681-210AEL (UL Listed)
Series Addressable Manual Pull Station (Call Point):
Model : AX-APS2-F1 (Intertek Listed)
Wall Mount Strobe and Horn Strobe:
Model: 28-GEC3-24WR (UL Listed)
Isolator Module:
Model: 55000-750AEL
Isolator Module Base:
Model : 45681-211AEL (UL Listed)
Dual Input Monitor Module:
Model:55000-805AEL (UL Listed)
Dual Relay Moudule :
Model:55000-863AEL (UL Listed)
Conduit:
Rigid; Standard PVC (Poly Vinyl Chloride)
No conduit is buried in this system.
Cable:
Fire Alarm Cable (FR)
Specification: UL Listed
01. For Sensors & Devices Circuit:
Fire Alarm Cable 2X1.5 (S) FPLR 50mm
UL Listed E355847
02. For Notification Application Circuit (NAC):
Fire Alarm Cable 2X2.5 (S) FPLR 50mm
UL Listed E355847
Spacing of Sensor Head:
Maximum Coverage Area: 900 ft² (83.65 m²)
(Considering 70% Coverage Area of Device )
01. For Flat Plate/Slab: 25 ft (7.62m) Max.
Starting from Spacing/2 from Wall/Partition.
02. For Patch Roof/Shed Roof: 25 ft (7.62m) Max.
Starting from Spacing/2 from Wall/Partition.
03. For Room: 1 Detector Per Room upto
Room Area 625 sft (58.08 sqm).
04. For Beam-Column Slab: 1 Detector Per Bay
upto Bay Area 625 sft (58.08 sqm)
Spacing Reduction Factor will be apply when
Floor Height ≤ 12'-0" (3.66 m)
Nunmer of Riser: 03
Circuit Type: Class-A For Sensor and
Class-B For Notification Application
Number of Circuit:
Riser-1: Class-A: 02(For Sensor), Class-B: 01(For Bell)
Riser-2: Class-A: 01(For Sensor), Class-B: 01(For Bell)
Riser-3: Class-A: 02(For Sensor), Class-B: 01(For Bell)
Emergency Power:
Emergency Power Shall be Provided for Automatic Fire Alarm with
Addressable Detection System.
Check the light source and air source before instellation of Sensors.
Sprinkler, Lift and HVAC System are not available in this facility.
1 2
FF
E
D
A
C
B
1
3 4 5 6 7 8
E
D
32 4 5 6 7
A
C
B
8
FACTORY NAMEDRAWING TITLE DATE & PAGE NO.
7th January 2018A
REV.CONSULTANT NAME CHECKED BYDESIGNED BY
Addressable Fire Detection &Alarm System
SEAL & SIGNATURE
Engr. Md. Arif Hossain
B.Sc in EEE
HOUSE # 09, ROAD # 03, NIKUNJO-2,
KHILKHET DHAKA-1229
E-mail:[email protected]
KiK-UCEP Hasemuddin School.Plot # 07, Road # 05, Block # B
Sat Mosjid Housing, Beribandh, Mohammadpur,Dhaka-1207
Engr.Md. Ibrahim Khalil
B.Sc in EEE
TE/UCEP/FDS/O2
FIGURE : EXAMPLE OF PROPER MOUNTING FOR DETECTOR. FIGURE : EXAMPLE OF PROPER MOUNTING FOR ALARMS AND DETECTORS WITH PEAKED CEILING.
FIGURE : DETECTOR SPACING LAY-OUT, SLOPE CEILINGS (SHED TYPE)
FIGURE : EXAMPLE OF PROPER MOUNTING FOR ALARMS AND DETECTORS WITH SLOPED CEILINGS.
FIGURE : MAXIMUM DISTANCE AT WHICH CEILING-SUSPENDED LIGHT PROJECTOR ANDRECEIVER CAN BE POSITIONED FROM END WALL IS ONE-QUARTER SELECTED SPACING (S).
FIGURE : SPOT-TYPE DETECTOR SPACING
FIGURE : DETECTOR SPACING LAYOUT, SOLID JOIST CONSTRUCTION.
FIGURE: CORRECT WIRING METHOD - TWO WIRE DETECTORS
FIGURE: INCORRECT WIRING METHOD - TWO WIRE DETECTORS
FIGURE: EXAMPLE OF CONCEAL PIPING MOUNTING
FIGURE:EXAMPLE OFSURFACEPIPINGMOUNTING
FIGURE: EXAMPLE OF MPS MOUNTING
FIGURE: EXAMPLE OF INSTALLATION DETAILS OF UNDERGROUND (BURIED) CABLE
FIGURE: EXAMPLE OF FACP MOUNTING
= DETECTOR S = SPACE BETWEEN DETECTOR
S
S
S
S S S.5S
.7S
.5S
.5S
.5S
S S S S S.5S
S =SPACE BETWEEN DETECTORS =DETECTORS
36 IN. (910 MM)MAXIMUM
36 IN.(910 MM)
36 IN.(910 MM)
NOT IN THIS AREA
ANYWHERE IN THIS AREA4 IN.
(100 MM)
CEILING
NOTE : MEASUREMENTS SHOWN ARE TOTHE CLOSEST EDGE OF THE DETECTOR.
ACCEPTABLE
NEVER HERE
12 IN.(300 MM)MAXIMUM
SIDEWALL
4 IN. (300 MM)MAXIMUM
TOP OF DETECTORACCEPTABLE HERE
4 IN.(100 MM)
4 IN. (100 MM)
36 IN. (910 MM)
ANYWHERE INTHIS AREA
NOT IN THIS AREAS = SPACE BETWEEN DETECTORS
DETECTORS ON BOTTOMOF JOISTS
.5S .5S .25S
SOLID JOISTS .5S
S
.5S
Receiver
ReceiverProjector
Projector .5S
S.5
S
.5S.5S
S=SELECTED DETECTOR SPACING
CONDUIT BASE
DETECTOR
SLAB
CONDUIT BASE
DETECTOR
SLAB
WARNING TAPE
FILLING SAND
CONCRETE TILE
SANDPVC DUCT
EXISTING SOIL
CABLE
SLAB
FINISHED FLOOR
WALL
FIRE ALARM CONTROL PANEL
MAINTAIN MINIMUM 3' CLEARAREA IN FRONT OF FACP
MOUNTING HEIGHT OF MPS IS INBETWEEN 42" TO 48" FROM THEFINISHED FLOOR.
MAXIMUM DISTANCE OF MPS IS 5' FROM EXIT POINT
EXIT
5'
D D D D
CONTROL UNITINITIATING DEVICECIRCUIT
DUPLICATETERMINALS
DUPLICATELEADS
SINGLE TERMINALNOTCHED CLAMPING PLATE
DUPLICATETERMINALS
SPLICES
BACK TO FACP
D D DCONTROL UNITINITIATING DEVICECIRCUIT
Single terminalnotched clamping plate
D
CIRCUIT WIRING LOOPEDUNDER ONE TERMINAL
ONE SPLICE LEADCONNECTED, OTHERTAPED AND NOT USED
CIRCUIT WIRE BENT BACKON ITSELF AND SECUREDIN ONE NOTCH
CIRCUIT WIRE LOOPEDUNDER TERMINAL;WIRE RUN NOT BROKEN
BACK TO FACP
SPACING, POSITION & MOUNTING EXAMPLE
FIGURE: EXAMPLE OF SOUNDER/SOUNDER BEACON MOUNTING
SOUNDER MOUNTING HEIGHTMINIMUM 90" ABOVE FROMFINISHED FLOOR
FINISHED FLOOR
SLAB
NOT LESS THEN 6"BELOW FROM CEILING
SOUNDER BEACON MOUNTINGHEIGHT IS BETWEEN 80" TO 96"ABOVE FROM FINISHED FLOOR
WALL
1 2
FF
E
D
A
C
B
1
3 4 5 6 7 8
E
D
32 4 5 6 7
A
C
B
8
FACTORY NAMEDRAWING TITLE DATE & PAGE NO.
7th January 2018A
REV.CONSULTANT NAME CHECKED BYDESIGNED BY
Addressable Fire Detection &Alarm System
SEAL & SIGNATURE
Engr. Md. Arif Hossain
B.Sc in EEE
HOUSE # 09, ROAD # 03, NIKUNJO-2,
KHILKHET DHAKA-1229
E-mail:[email protected]
KiK-UCEP Hasemuddin School.Plot # 07, Road # 05, Block # B
Sat Mosjid Housing, Beribandh, Mohammadpur,Dhaka-1207
Engr.Md. Ibrahim Khalil
B.Sc in EEE
1250
MOUNTING DETAIL OF ADDRESSABLE
FIRE ALARM BELL/SOUNDER
OF HORN/STROBE
E R I F
MOUNTING DETAIL OF FIRE ALARM
CONTROL PANEL
MOUNTING DETAIL
De
vice
M
ou
ntin
g D
eta
ils
TE/UCEP/FDS/O3
R O A D
R O
A
D
Guard Room
MASTER PLAN
UP
FACP (2-Loop)
Cabl
e Ri
ser-
03
Cable Riser-01
4 Storied RCC Building
Instellation Details ofUnderground (Buried) Cable
6'12
"12
"6"
Finished Grade Level
Warning Tape
PVC Duct
Cable
Fine Washed Sand
Filling Sand
Existing Soil Layer
50mm Thick Concrete Tile
Under Ground (Buried) Cable Line
FACP-01 (2-LOOP)
SECO
NDAR
Y PO
WER
CON
NECT
ION
FOR
FACP
FRO
M IP
S
PRIM
ARY
POW
ER C
ONNE
CTIO
NFO
R FA
CP F
ROM
SDB
SDB
IPSBattery :2x12 V, 20 AH
PROV
ISIO
N FO
R FU
TURE
DIR
ECT
CONN
ECTI
ON O
FTH
E FI
RE A
LARM
AND
DET
ECTI
ON S
YSTE
M T
OA
CENT
RAL
STAT
ION
MON
ITOR
ING
SERV
ICE
OF T
HEFI
RE S
ERVI
CE A
ND C
IVIL
DEF
ENCE
Annunciator
SPEA
R NA
C-2,
FAC
P-01
RETU
RN L
OOP-
01, F
ACP-
01
STAR
T LO
OP-0
1, F
ACP-
01
SPEA
R LO
OP-0
2, F
ACP-
01
SPEA
R LO
OP-0
2, F
ACP-
01
STAR
T NA
C-1,
FAC
P-01
OUTDOOR WALL SUPPORTEDCABLE LAYING DETEAILS
Standard PVC(Poly Vinyl Chloride)Conduit
Fire Resistive Rated Cable
Band Strap/U-Bolt/C-Clump
R.C/Brick WallSteel Channel
Expansion Bolt
12
FFEDA CB
1
34
56
78
ED
32
4 5
67
A CB
8
FA
CT
OR
Y N
AM
ED
RA
WIN
G T
IT
LE
DA
TE
&
P
AG
E N
O.
7th
Janu
ary
2018
A
RE
V.
CO
NS
UL
TA
NT
N
AM
E
CH
EC
KE
D B
YD
ES
IG
NE
D B
Y
Addr
essa
ble
Fire
Det
ectio
n &
Alar
m S
yste
m
SE
AL
&
S
IG
NA
TU
RE
Engr. M
d. Arif H
ossain
B.Sc in EEE
HO
US
E #
0
9, R
OA
D #
0
3, N
IK
UN
JO
-2
,
KH
IL
KH
ET
D
HA
KA
-1
22
9
E-m
ail:te
ch
nic.e
ng
in
ee
rin
gb
d@
gm
ail.co
m
KiK
-UC
EP H
asem
uddi
n Sc
hool
.Pl
ot #
07,
Roa
d #
05, B
lock
# B
Sat M
osjid
Hou
sing
, Ber
iban
dh, M
oham
mad
pur,
Dha
ka-1
207
Engr
.Md.
Ibra
him
Kha
lil
B.Sc
in E
EE
TE/U
CEP/
FDS/
O4
Drive Way
Guard Room
Green
GROUND FLOOR PLAN
Toilet Toilet
Tea Room
Toilet
Store
Store Room
Head Techer Room
Parking Area
Garden
UP
UP
UP
P
P
P
P
P
P
F
F
P
P
F
F
P
P
P
P
P
P
P
FACP (2-Loop)
Cabl
e Ri
ser-
03
Cable Riser-01
LOOP
-01,
CP-0
1, C
ontin
ue to
1st
Flo
or
LOOP-01,CP-01, StartFrom FACP Room
FH
FH
NAC-
01,C
P-01
, Con
tinue
to 1
st F
loor
CP-01,L-01SD-1,DN-2
CP-01,L-01SD-2,DN-3
CP-01,L-01SD-3,DN-4
CP-01,L-01SD-4,DN-5
CP-01,L-01SD-5,DN-6
CP-01,L-01SD-6,DN-7
CP-01,L-01SD-8,DN-10
CP-01,L-01SD-7,DN-9
CP-01,L-01SD-9,DN-11
CP-01,L-01SD-10,DN-12
CP-01,L-01SD-11,DN-14
CP-01,L-01SD-12,DN-16
CP-01,L-01SD-13,DN-18
CP-01,L-01HD-1,DN-13
CP-01,L-01HD-2,DN-15
CP-01,L-01HD-3,DN-17
CP-01,L-01HD-4,DN-19
CP-01,L-01P-2,DN-8
CP-01,L-01P-1,DN-1
CP-01,N-01,B-1
CP-01,N-01,B-2
RC
C B
EAM
SLA
B10
'-6"
21'-5
"21
'-5"
21'-5
"21
'-3"
10'-4
"
SECT
ION:
X-X
OF
UCEP
Hes
amud
din
Scho
ol
21'-0
"21
'-5"
21'-1
0"21
'-5"
21'-0
"
15'-0" 17'-10" 9'-10"
20'-2
"15
'-5"
11'-3
"9'-10"12'-0"
2-HOur fire rated wall
addressable multi sensorCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-886AEL
LEGENDSYMBOL NAMESYMBOL
P
addressable HEAT SENSORCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-450AEL
BELL/HORN STROBEBrand: Advanced, Origin: UKModel:28-GEC3-24WR
MCP/dUAL-ACTION MANUALPULL STATIONBrand: Advanced, Origin: UKModel:AX-APS2-F1
FACP (Loop-N)
RM/DUAL RELAY MODULEBrand: Advanced, Origin: UKModel:55000-863AEL
FACP/ADDRESSABLE FIRE ALARMCONTROL PANELBrand: AdvancedModel: AX-CTL-2 & AX-CTL-4
For SENSOR & devices:2X1.5 mm² (Soild) FR Cable
For Fire Alarm (NAC):2X2.5 mm² (Solid) FR Cable
PROPOSED FIRE DOOR
END OF LINE RESISTOR
EXHaUST FAN
Cable RISER
MM/DUAL INPUT MONITORBrand: Advanced, Origin: UKModel:55000-805AEL
1-HOur fire rated wall
addressable PHOTO ELECTRICSMOKE SENSORCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-650AEL
hydrant RISER
Exhaust Fan EXHaUST FAN AIR DELIVERY
EOLR
R
P
F
FH
AOM
AIM
RCC
BEAM
LIN
EFU
LL H
EIGH
T W
ALL
HALF
HEI
GHT
WAL
L
10'-1
"10
'-1"
10"
10'-4
"10
'-4"
10"
10'-6
"10
'-6"
10"
10'-4
"10
'-4"
10"
10'-1
"10
'-1"
7'-1" 7'-1"
7'-1" 7'-1"
7'-1" 7'-1"
7'-1" 7'-1"
12'-4
"
12'-4
"
10'-1
1"21
'-3"
18'-8
"24
'-7"
20'-1
0"9'
-8"
6'-0" 6'-0"
7'-1
1"7'
-11"
4'-6" 4'-6"
2'-0
"2'
-0"
2'-1
0"2'
-10"
4'-3
"4'
-3"
6'-0" 6'-0"
7'-9
"7'
-9"
9'-1
1"9'
-11"
4'-8" 4'-9"
6'-9" 6'-9"5'-0
"5'
-0"
X
X
12
FFEDA CB
1
34
56
78
ED
32
4 5
67
A CB
8
FA
CT
OR
Y N
AM
ED
RA
WIN
G T
IT
LE
DA
TE
&
P
AG
E N
O.
7th
Janu
ary
2018
A
RE
V.
CO
NS
UL
TA
NT
N
AM
E
CH
EC
KE
D B
YD
ES
IG
NE
D B
Y
Addr
essa
ble
Fire
Det
ectio
n &
Alar
m S
yste
m
SE
AL
&
S
IG
NA
TU
RE
Engr. M
d. Arif H
ossain
B.Sc in EEE
HO
US
E #
0
9, R
OA
D #
0
3, N
IK
UN
JO
-2
,
KH
IL
KH
ET
D
HA
KA
-1
22
9
E-m
ail:te
ch
nic.e
ng
in
ee
rin
gb
d@
gm
ail.co
m
KiK
-UC
EP H
asem
uddi
n Sc
hool
.Pl
ot #
07,
Roa
d #
05, B
lock
# B
Sat M
osjid
Hou
sing
, Ber
iban
dh, M
oham
mad
pur,
Dha
ka-1
207
Engr
.Md.
Ibra
him
Kha
lil
B.Sc
in E
EE
TE/U
CEP/
FDS/
O5
Floor Data:Floor Area:3289.244 squareft.(Approx.)Ceiling Type:Beam ColumnBeam Depth:10''Beam Depth:13''
FIRST FLOOR PLAN
21'-0
"21
'-5"
21'-1
0"21
'-5"
21'-0
"
15'-0" 17'-10" 9'-10"
20'-2
"15
'-5"
11'-3
"
9'-10"12'-0"
Toilet Toilet
Toilet Toilet
Womens Corner
Toilet
Techers Room
Class Room
Class Room
Class Room
Class Room
Class Room
UP
P
P
P
P
P
P
P
P
P
F
F
PP
P
F
P
Cabl
e Ri
ser-
03
Cable Riser-01
P
PF
HF
H
LOOP
-01,
CP-0
1, C
ontin
ue F
rom
1st
Flo
orNA
C-01
,CP-
01, C
ontin
ue F
rom
1st
Flo
or
NAC-01,CP-01, Continue to 2nd Floor
LOOP-01,CP-01, Continue to 2nd Floor
CP-01,L-01SD-26,DN-37
CP-01,L-01SD-25,DN-36
CP-01,L-01SD-24,DN-35
CP-01,L-01SD-23,DN-34
CP-01,L-01SD-22,DN-33
CP-01,L-01SD-21,DN-31
CP-01,L-01SD-18,DN-28
CP-01,L-01SD-20,DN-30
CP-01,L-01SD-19,DN-29
CP-01,L-01SD-16,DN-23
CP-01,L-01SD-15,DN-22
CP-01,L-01SD-17,DN-27
CP-01,L-01SD-14,DN-20
CP-01,L-01HD-6,DN-25
CP-01,L-01HD-7,DN-26
CP-01,L-01P-4,DN-32
CP-01,L-01P-3,DN-21
CP-01,L-01HD-5,DN-24
CP-01,N-01,B-3
CP-01,N-01,B-4
10'-6
"10
'-6"
5"10
'-6"
10'-6
"5"
10'-6
"10
'-6"
5"10
'-6"
10'-6
"5"
10'-4
"10
'-4"
7'-6" 7'-6"
12'-5
"
12'-6"
11'-2
"22
'-5"
11'-2
"10
"11
'-5"
22'-1
0"11
'-5"
2'-8" 2'-9"
7'-6" 7'-6"
7'-1
1"7'
-11"
6'-0" 6'-0"
5'-1
"5'
-1"
6'-0" 6'-0"
4'-3
"4'
-2"
7'-6
"7'
-6"
10"
7'-6
"7'
-6"
4'-9" 4'-8"
4'-9" 4'-8"
2'-5
"2'
-5"
6'-11" 7'-0"
5'-0
"5'
-0"
RC
C B
EAM
SLA
B
Clas
s Ro
omOc
cupe
ncy-
F1
Clas
s Ro
omOc
cupe
ncy-
F1
Clas
s Ro
omOc
cupe
ncy-
F1
Clas
s Ro
omOc
cupe
ncy-
F1
Clas
s Ro
omOc
cupe
ncy-
F1
10'-6
"21
'-5"
21'-5
"21
'-5"
21'-3
"10
'-4"
2-HOur fire rated wall
addressable multi sensorCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-886AEL
LEGENDSYMBOL NAMESYMBOL
P
addressable HEAT SENSORCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-450AEL
BELL/HORN STROBEBrand: Advanced, Origin: UKModel:28-GEC3-24WR
MCP/dUAL-ACTION MANUALPULL STATIONBrand: Advanced, Origin: UKModel:AX-APS2-F1
FACP (Loop-N)
RM/DUAL RELAY MODULEBrand: Advanced, Origin: UKModel:55000-863AEL
FACP/ADDRESSABLE FIRE ALARMCONTROL PANELBrand: AdvancedModel: AX-CTL-2 & AX-CTL-4
For SENSOR & devices:2X1.5 mm² (Soild) FR Cable
For Fire Alarm (NAC):2X2.5 mm² (Solid) FR Cable
PROPOSED FIRE DOOR
END OF LINE RESISTOR
EXHaUST FAN
Cable RISER
MM/DUAL INPUT MONITORBrand: Advanced, Origin: UKModel:55000-805AEL
1-HOur fire rated wall
addressable PHOTO ELECTRICSMOKE SENSORCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-650AEL
hydrant RISER
Exhaust Fan EXHaUST FAN AIR DELIVERY
EOLR
R
P
F
FH
AOM
AIM
SECT
ION:
X-X
OF
UCEP
Hes
amud
din
Scho
ol
RCC BEAM LINEFULL HEIGHT WALLHALF HEIGHT WALL
X
X
12
FFEDA CB
1
34
56
78
ED
32
4 5
67
A CB
8
FA
CT
OR
Y N
AM
ED
RA
WIN
G T
IT
LE
DA
TE
&
P
AG
E N
O.
7th
Janu
ary
2018
A
RE
V.
CO
NS
UL
TA
NT
N
AM
E
CH
EC
KE
D B
YD
ES
IG
NE
D B
Y
Addr
essa
ble
Fire
Det
ectio
n &
Alar
m S
yste
m
SE
AL
&
S
IG
NA
TU
RE
Engr. M
d. Arif H
ossain
B.Sc in EEE
HO
US
E #
0
9, R
OA
D #
0
3, N
IK
UN
JO
-2
,
KH
IL
KH
ET
D
HA
KA
-1
22
9
E-m
ail:te
ch
nic.e
ng
in
ee
rin
gb
d@
gm
ail.co
m
KiK
-UC
EP H
asem
uddi
n Sc
hool
.Pl
ot #
07,
Roa
d #
05, B
lock
# B
Sat M
osjid
Hou
sing
, Ber
iban
dh, M
oham
mad
pur,
Dha
ka-1
207
Engr
.Md.
Ibra
him
Kha
lil
B.Sc
in E
EE
TE/U
CEP/
FDS/
O6
Floor Data:Floor Area:3289.244 squareft.(Approx.)Ceiling Type:Beam ColumnBeam Depth:10''Beam Depth:13''
SECOND FLOOR PLAN
Class Room
Class Room
Class Room
Class Room
Class Room
UP
Toilet Toilet
Toilet Toilet
Library
Meeting Room
P
P
P
P
P
P
P
F
F
P
P
P
P
P
P
P
Cabl
e Ri
ser-
03
Cable Riser-01
P
PF
HF
H
LOOP
-01,
CP-0
1, C
ontin
ue to
3rd
Flo
orNA
C-01
,CP-
01, C
ontin
ue to
3rd
Flo
or
NAC-01,CP-01, Continue From 1st Floor
LOOP-01,CP-01, Continue From 1st Floor
CP-01,L-01SD-27,DN-38
CP-01,L-01SD-29,DN-40
CP-01,L-01SD-30,DN-41
CP-01,L-01SD-31,DN-42
CP-01,L-01SD-32,DN-43
CP-01,L-01SD-33,DN-45
CP-01,L-01SD-36,DN-48
CP-01,L-01SD-34,DN-46 CP-01,L-01
SD-35,DN-47
CP-01,L-01SD-38,DN-52
CP-01,L-01SD-39,DN-53
CP-01,L-01SD-37,DN-49
CP-01,L-01SD-40,DN-55
CP-01,L-01HD-9,DN-51
CP-01,L-01HD-8,DN-50
CP-01,L-01P-5,DN-44
CP-01,L-01P-6,DN-54
CP-01,L-01SD-28,DN-39
10'-6
"10
'-6"
5"10
'-6"
10'-6
"5"
10'-6
"10
'-6"
5"10
'-6"
10'-6
"5"
10'-4
"10
'-4"
11'-5
"22
'-10"
11'-5
"9'
-10"
19'-8
"19
'-8"
9'-1
0"
7'-6
"18
'-5"
10'-1
"
7'-1
1"7'
-11"
6'-0" 6'-0"
4'-9" 4'-8"
7'-0" 6'-11"
5'-0
"5'
-0"
2'-8" 2'-9"
CP-01,N-01,B-5
CP-01,N-01,B-6
7'-6" 7'-6"
7'-6" 7'-6"
2'-8" 2'-9"
5'-1
"5'
-1"
5"4'
-3"
4'-3
"
6'-0" 6'-0"
RC
C B
EAM
SLA
B
Clas
s Ro
omOc
cupe
ncy-
F1
Clas
s Ro
omOc
cupe
ncy-
F1
Clas
s Ro
omOc
cupe
ncy-
F1
Clas
s Ro
omOc
cupe
ncy-
F1
Clas
s Ro
omOc
cupe
ncy-
F1
10'-6
"21
'-5"
21'-5
"21
'-5"
21'-3
"10
'-4"
21'-0
"21
'-5"
21'-1
0"21
'-5"
21'-0
"
15'-0" 17'-10" 9'-10"
20'-2
"15
'-5"
11'-3
"
9'-10"12'-0"
SECT
ION:
X-X
OF
UCEP
Hes
amud
din
Scho
ol
2-HOur fire rated wall
addressable multi sensorCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-886AEL
LEGENDSYMBOL NAMESYMBOL
P
addressable HEAT SENSORCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-450AEL
BELL/HORN STROBEBrand: Advanced, Origin: UKModel:28-GEC3-24WR
MCP/dUAL-ACTION MANUALPULL STATIONBrand: Advanced, Origin: UKModel:AX-APS2-F1
FACP (Loop-N)
RM/DUAL RELAY MODULEBrand: Advanced, Origin: UKModel:55000-863AEL
FACP/ADDRESSABLE FIRE ALARMCONTROL PANELBrand: AdvancedModel: AX-CTL-2 & AX-CTL-4
For SENSOR & devices:2X1.5 mm² (Soild) FR Cable
For Fire Alarm (NAC):2X2.5 mm² (Solid) FR Cable
PROPOSED FIRE DOOR
END OF LINE RESISTOR
EXHaUST FAN
Cable RISER
MM/DUAL INPUT MONITORBrand: Advanced, Origin: UKModel:55000-805AEL
1-HOur fire rated wall
addressable PHOTO ELECTRICSMOKE SENSORCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-650AEL
hydrant RISER
Exhaust Fan EXHaUST FAN AIR DELIVERY
EOLR
R
P
F
FH
AOM
AIM
RCC BEAM LINEFULL HEIGHT WALLHALF HEIGHT WALL
X
X
12
FFEDA CB
1
34
56
78
ED
32
4 5
67
A CB
8
FA
CT
OR
Y N
AM
ED
RA
WIN
G T
IT
LE
DA
TE
&
P
AG
E N
O.
7th
Janu
ary
2018
A
RE
V.
CO
NS
UL
TA
NT
N
AM
E
CH
EC
KE
D B
YD
ES
IG
NE
D B
Y
Addr
essa
ble
Fire
Det
ectio
n &
Alar
m S
yste
m
SE
AL
&
S
IG
NA
TU
RE
Engr. M
d. Arif H
ossain
B.Sc in EEE
HO
US
E #
0
9, R
OA
D #
0
3, N
IK
UN
JO
-2
,
KH
IL
KH
ET
D
HA
KA
-1
22
9
E-m
ail:te
ch
nic.e
ng
in
ee
rin
gb
d@
gm
ail.co
m
KiK
-UC
EP H
asem
uddi
n Sc
hool
.Pl
ot #
07,
Roa
d #
05, B
lock
# B
Sat M
osjid
Hou
sing
, Ber
iban
dh, M
oham
mad
pur,
Dha
ka-1
207
Engr
.Md.
Ibra
him
Kha
lil
B.Sc
in E
EE
TE/U
CEP/
FDS/
O7
Floor Data:Floor Area:3289.244 squareft.(Approx.)Ceiling Type:Beam ColumnBeam Depth:10''Beam Depth:13''
THIRD FLOOR PLAN
Electrician
Trade Room
UP
Toilet
Toilet Toilet
Electric E
sem
bling
Technic R
oom
Open To Sky
Op
en
T
o S
ky
F
P
P
F
P
P
P
P
P
P
P
P
Cabl
e Ri
ser-
03
P
FH
LOOP
-01,
CP-0
1, C
ontin
ue F
rom
2nd
Flo
orNA
C-01
,CP-
01, C
ontin
ue F
rom
2nd
Flo
or
LOOP
-01,
CP-0
1, C
ontin
ue to
Roo
f Top
NAC-
01,C
P-01
, Ret
urn
to F
ACP
Room
CP-01,L-01P-7,DN-66
CP-01,L-01HD-10,DN-59
CP-01,L-01HD-11,DN-60
CP-01,L-01SD-45,DN-62
CP-01,L-01SD-44,DN-61
CP-01,L-01SD-46,DN-63
CP-01,L-01SD-43,DN-58
CP-01,L-01SD-42,DN-57
CP-01,L-01SD-41,DN-56
CP-01,L-01SD-48,DN-65
CP-01,L-01SD-47,DN-64
CP-01,L-01SD-50,DN-68
CP-01,L-01SD-49,DN-67
CP-01,N-01,B-7
RC
C B
EAM
SLA
B
Elec
trici
an T
rade
Roo
mOc
cupe
ncy-
F1
21'-3
"10
'-1"
10'-9
"2'
-0"
2'-0
"
SECT
ION:
X-X
OF
UCEP
Hes
amud
din
Scho
ol
21'-5
"21
'-0"
15'-0" 17'-10" 9'-10"
20'-2
"15
'-5"
11'-3
"
9'-10"12'-0"
2-HOur fire rated wall
addressable multi sensorCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-886AEL
LEGENDSYMBOL NAMESYMBOL
P
addressable HEAT SENSORCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-450AEL
BELL/HORN STROBEBrand: Advanced, Origin: UKModel:28-GEC3-24WR
MCP/dUAL-ACTION MANUALPULL STATIONBrand: Advanced, Origin: UKModel:AX-APS2-F1
FACP (Loop-N)
RM/DUAL RELAY MODULEBrand: Advanced, Origin: UKModel:55000-863AEL
FACP/ADDRESSABLE FIRE ALARMCONTROL PANELBrand: AdvancedModel: AX-CTL-2 & AX-CTL-4
For SENSOR & devices:2X1.5 mm² (Soild) FR Cable
For Fire Alarm (NAC):2X2.5 mm² (Solid) FR Cable
PROPOSED FIRE DOOR
END OF LINE RESISTOR
EXHaUST FAN
Cable RISER
MM/DUAL INPUT MONITORBrand: Advanced, Origin: UKModel:55000-805AEL
1-HOur fire rated wall
addressable PHOTO ELECTRICSMOKE SENSORCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-650AEL
hydrant RISER
Exhaust Fan EXHaUST FAN AIR DELIVERY
EOLR
R
P
F
FH
AOM
AIM
RCC BEAM LINEFULL HEIGHT WALLHALF HEIGHT WALL
X
X
4'-9"4'-8"5"8'-9"16'-10"7'-3"
10'-9
"21
'-3"
10'-1
"
5'-3
"9'
-8"
4'-5
"
6'-11" 7'-0"
5'-0
"5'
-0"
7'-6
"15
'-10"
7'-6
"
2'-5
"2'
-5"
12
FFEDA CB
1
34
56
78
ED
32
4 5
67
A CB
8
FA
CT
OR
Y N
AM
ED
RA
WIN
G T
IT
LE
DA
TE
&
P
AG
E N
O.
7th
Janu
ary
2018
A
RE
V.
CO
NS
UL
TA
NT
N
AM
E
CH
EC
KE
D B
YD
ES
IG
NE
D B
Y
Addr
essa
ble
Fire
Det
ectio
n &
Alar
m S
yste
m
SE
AL
&
S
IG
NA
TU
RE
Engr. M
d. Arif H
ossain
B.Sc in EEE
HO
US
E #
0
9, R
OA
D #
0
3, N
IK
UN
JO
-2
,
KH
IL
KH
ET
D
HA
KA
-1
22
9
E-m
ail:te
ch
nic.e
ng
in
ee
rin
gb
d@
gm
ail.co
m
KiK
-UC
EP H
asem
uddi
n Sc
hool
.Pl
ot #
07,
Roa
d #
05, B
lock
# B
Sat M
osjid
Hou
sing
, Ber
iban
dh, M
oham
mad
pur,
Dha
ka-1
207
Engr
.Md.
Ibra
him
Kha
lil
B.Sc
in E
EE
TE/U
CEP/
FDS/
O8
Floor Data:Floor Area:1955.921 squareft.(Approx.)Ceiling Type:Beam ColumnBeam Depth:10''Beam Depth:13''
ROOF TOP PLAN
Open To Sky
Op
en
T
o S
ky
P P
Cable Riser-03
LOOP
-01,
CP-0
1, C
ontin
ue F
rom
3rd
Flo
orLO
OP-0
1,CP
-01,
Ret
urn
to F
ACP
Room
CP-01,L-01SD-51,DN-69
CP-01,L-01SD-52,DN-70
5'-0
"5'
-0"
2'-11" 2'-11"
2'-0" 2'-1"1
2
FFEDA CB
1
34
56
78
ED
32
4 5
67
A CB
8
FA
CT
OR
Y N
AM
ED
RA
WIN
G T
IT
LE
DA
TE
&
P
AG
E N
O.
7th
Janu
ary
2018
A
RE
V.
CO
NS
UL
TA
NT
N
AM
E
CH
EC
KE
D B
YD
ES
IG
NE
D B
Y
Addr
essa
ble
Fire
Det
ectio
n &
Alar
m S
yste
m
SE
AL
&
S
IG
NA
TU
RE
Engr. M
d. Arif H
ossain
B.Sc in EEE
HO
US
E #
0
9, R
OA
D #
0
3, N
IK
UN
JO
-2
,
KH
IL
KH
ET
D
HA
KA
-1
22
9
E-m
ail:te
ch
nic.e
ng
in
ee
rin
gb
d@
gm
ail.co
m
KiK
-UC
EP H
asem
uddi
n Sc
hool
.Pl
ot #
07,
Roa
d #
05, B
lock
# B
Sat M
osjid
Hou
sing
, Ber
iban
dh, M
oham
mad
pur,
Dha
ka-1
207
Engr
.Md.
Ibra
him
Kha
lil
B.Sc
in E
EE
TE/U
CEP/
FDS/
O9
RCC BEAM SLAB10'-6" 21'-5" 21'-5" 21'-5" 21'-2" 10'-4"
SECTION: X-X OF UCEP Hesamuddin School
RCC BEAM SLAB
Class RoomOccupency- F1
Class RoomOccupency- F1
Class RoomOccupency- F1
Class RoomOccupency- F1
Class RoomOccupency- F1
10'-6" 21'-5" 21'-5" 21'-5" 21'-2" 10'-4"
RCC BEAM SLAB
Class RoomOccupency- F1
Class RoomOccupency- F1
Class RoomOccupency- F1
Class RoomOccupency- F1
Class RoomOccupency- F1
10'-6" 21'-5" 21'-5" 21'-5" 21'-2" 10'-4"
RCC BEAM SLAB
Electrician Trade RoomOccupency- F1
21'-3" 10'-1"10'-9"
1 2
FF
E
D
A
C
B
1
3 4 5 6 7 8
E
D
32 4 5 6 7
A
C
B
8
FACTORY NAMEDRAWING TITLE DATE & PAGE NO.
7th January 2018A
REV.CONSULTANT NAME CHECKED BYDESIGNED BY
Addressable Fire Detection &Alarm System
SEAL & SIGNATURE
Engr. Md. Arif Hossain
B.Sc in EEE
HOUSE # 09, ROAD # 03, NIKUNJO-2,
KHILKHET DHAKA-1229
E-mail:[email protected]
KiK-UCEP Hasemuddin School.Plot # 07, Road # 05, Block # B
Sat Mosjid Housing, Beribandh, Mohammadpur,Dhaka-1207
Engr.Md. Ibrahim Khalil
B.Sc in EEE
TE/UCEP/FDS/10
2 Loop Addressable Fire Alarm Control Panel ( FACP-01 )
LOOP-1 LOOP-2
SINGLE LINE DIAGRAM OF CONTROL PANEL
Control Panel Location : Ground Floor ( Proposed Fire Control Room)
LOOP
-01,
Sta
rt fro
m F
ACP-
1
LOOP
-01,
Ret
urne
d to
FAC
P-1
Gro
und
Flo
or
CABL
E RI
SER-
1
CABL
E RI
SER-
1
NAC-1 NAC-2
LOOP
-02,
SPE
AR
LOOP
-02,
SPE
AR
NAC-
01, S
tart
from
FAC
P-1
NAC-
02, S
PEAR
P
CP-0
1,L-
01,S
D-1,
DN-2
CP-0
1,L-
01,P
-1,D
N-1
PP
CP-0
1,L-
01,S
D-2,
DN-3
P
CP-0
1,L-
01,S
D-3,
DN-4
P
CP-0
1,L-
01,S
D-4,
DN-5
P
CP-0
1,L-
01,S
D-5,
DN-6
P
CP-0
1,L-
01,S
D-6,
DN-7
CP-0
1,L-
01,P
-2,D
N-8
PP
CP-0
1,L-
01,S
D-7,
DN-9
P
CP-0
1,L-
01,S
D-8,
DN-1
0
P
CP-0
1,L-
01,S
D-9,
DN-1
1
P
CP-0
1,L-
01,S
D-10
,DN-
12
CP-0
1,L-
01,H
D-1,
DN-1
3
F P
CP-0
1,L-
01,S
D-11
,DN-
14
CP-0
1,L-
01,H
D-2,
DN-1
5
F P
CP-0
1,L-
01,S
D-12
,DN-
16
CP-0
1,L-
01,H
D-3,
DN-1
7
F P
CP-0
1,L-
01,S
D-13
,DN-
18
CP-0
1,L-
01,H
D-4,
DN-1
9
F
FH
CP-01,N-1,B-1
FH
CP-01,N-1,B-2
FH
CP-01,N-1,B-4
FH
CP-01,N-1,B-3
First
Flo
or
P
CP-0
1,L-
01,S
D-14
,DN-
20
CP-0
1,L-
01,P
-3,D
N-21
PP
CP-0
1,L-
01,S
D-15
,DN-
22
CP-0
1,L-
01,H
D-5,
DN-2
4
F
CP-0
1,L-
01,H
D-6,
DN-2
5
F
CP-0
1,L-
01,H
D-7,
DN-2
6
FP
CP-0
1,L-
01,S
D-17
,DN-
27
P
CP-0
1,L-
01,S
D-21
,DN-
31
P
CP-0
1,L-
01,S
D-20
,DN-
30
P
CP-0
1,L-
01,S
D-19
,DN-
29
P
CP-0
1,L-
01,S
D-18
,DN-
28
CP-0
1,L-
01,P
-4,D
N-32
PP
CP-0
1,L-
01,S
D-22
,DN-
33P
CP-0
1,L-
01,S
D-26
,DN-
37
P
CP-0
1,L-
01,S
D-25
,DN-
36
P
CP-0
1,L-
01,S
D-24
,DN-
35
P
CP-0
1,L-
01,S
D-23
,DN-
34
FH
CP-01,N-1,B-5
FH
CP-01,N-1,B-6
Sec
ond
Flo
or
FH
CP-01,N-1,B-7
Third
Flo
orRoo
f Top
EOLR
P
CP-0
1,L-
01,S
D-31
,DN-
42
P
CP-0
1,L-
01,S
D-27
,DN-
38
P
CP-0
1,L-
01,S
D-28
,DN-
39
P
CP-0
1,L-
01,S
D-29
,DN-
40
P
CP-0
1,L-
01,S
D-30
,DN-
41
P
CP-0
1,L-
01,S
D-32
,DN-
43
CP-0
1,L-
01,P
-5,D
N-44
PP
CP-0
1,L-
01,S
D-36
,DN-
48
P
CP-0
1,L-
01,S
D-33
,DN-
45
P
CP-0
1,L-
01,S
D-34
,DN-
46
P
CP-0
1,L-
01,S
D-35
,DN-
47
P
CP-0
1,L-
01,S
D-37
,DN-
49
CP-0
1,L-
01,H
D-9,
DN-5
1
F
CP-0
1,L-
01,H
D-8,
DN-5
0
F P
CP-0
1,L-
01,S
D-38
,DN-
52
P
CP-0
1,L-
01,S
D-39
,DN-
53
CP-0
1,L-
01,P
-6,D
N-54
PP
CP-0
1,L-
01,S
D-40
,DN-
55
P
CP-0
1,L-
01,S
D-41
,DN-
56
P
CP-0
1,L-
01,S
D-43
,DN-
58
P
CP-0
1,L-
01,S
D-42
,DN-
57
CP-0
1,L-
01,H
D-10
,DN-
59
F
CP-0
1,L-
01,H
D-11
,DN-
60
FP
CP-0
1,L-
01,S
D-45
,DN-
62
P
CP-0
1,L-
01,S
D-48
,DN-
65
P
CP-0
1,L-
01,S
D-47
,DN-
64
P
CP-0
1,L-
01,S
D-46
,DN-
63
P
CP-0
1,L-
01,S
D-44
,DN-
61
CP-0
1,L-
01,P
-7,D
N-66
PP
CP-0
1,L-
01,S
D-50
,DN-
68
P
CP-0
1,L-
01,S
D-49
,DN-
67
P
CP-0
1,L-
01,S
D-51
,DN-
69
P
CP-0
1,L-
01,S
D-52
,DN-
70
P
CP-0
1,L-
01,S
D-16
,DN-
23
CABL
E RI
SER-
2
2-HOur fire rated wall
addressable multi sensorCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-886AEL
LEGENDSYMBOL NAMESYMBOL
P
addressable HEAT SENSORCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-450AEL
BELL/HORN STROBEBrand: Advanced, Origin: UKModel:28-GEC3-24WR
MCP/dUAL-ACTION MANUALPULL STATIONBrand: Advanced, Origin: UKModel:AX-APS2-F1
FACP (Loop-N)
RM/DUAL RELAY MODULEBrand: Advanced, Origin: UKModel:55000-863AEL
FACP/ADDRESSABLE FIRE ALARMCONTROL PANELBrand: AdvancedModel: AX-CTL-2 & AX-CTL-4
For SENSOR & devices:2X1.5 mm² (Soild) FR Cable
For Fire Alarm (NAC):2X2.5 mm² (Solid) FR Cable
PROPOSED FIRE DOOR
END OF LINE RESISTOR
EXHaUST FAN
Cable RISER
MM/DUAL INPUT MONITORBrand: Advanced, Origin: UKModel:55000-805AEL
1-HOur fire rated wall
addressable PHOTO ELECTRICSMOKE SENSORCoverage Area (900 sft)Brand: Advanced, Origin: UKModel: 55000-650AEL
hydrant RISER
Exhaust Fan EXHaUST FAN AIR DELIVERY
EOLR
R
P
F
FH
AOM
AIM
CP-00, L-00, HD/ SD/ P / DN
DEVICE NUMBER
LOOP NUMBER
SMOKE DETECTORADDRESSABLE PULL STATION
CONTROL PANEL
HEAT DETECTOR
CP-00,NAC-0,B-0
BELL NUMBER
NAC NUMBER
CONTROL PANEL
Number of Riser: 03
Circuit Type: Class-A For Sensor and
Class-B For Notification Application
Number of Circuit:
Riser-1: Class-A: 02(For Sensor), Class-B: 01(For Bell)
Riser-2: Class-A: 01(For Sensor), Class-B: 01(For Bell)
Riser-3: Class-A: 02(For Sensor), Class-B: 01(For Bell)
KiK-UCEP Hesamuddin School
2.5r
m F
ire A
larm
Cab
le
1.5r
m F
ire A
larm
Cab
le
1.5r
m F
ire A
larm
Cab
le
2.5r
m F
ire A
larm
Cab
le
1 2
FF
E
D
A
C
B
1
3 4 5 6 7 8
E
D
32 4 5 6 7
A
C
B
8
FACTORY NAMEDRAWING TITLE DATE & PAGE NO.
7th January 2018A
REV.CONSULTANT NAME CHECKED BYDESIGNED BY
Addressable Fire Detection &Alarm System
SEAL & SIGNATURE
Engr. Md. Arif Hossain
B.Sc in EEE
HOUSE # 09, ROAD # 03, NIKUNJO-2,
KHILKHET DHAKA-1229
E-mail:[email protected]
KiK-UCEP Hasemuddin School.Plot # 07, Road # 05, Block # B
Sat Mosjid Housing, Beribandh, Mohammadpur,Dhaka-1207
Engr.Md. Ibrahim Khalil
B.Sc in EEE
TE/UCEP/FDS/11
P
F
R
FACP
AOM
AIM
IM
A B C D E F G H I J K M N O Q R S T
Actu
ate c
omm
on al
arm
sign
al in
dica
tor
Actu
ate au
dibl
e ala
rm si
gnal
Actu
ate c
omm
on su
perv
isory
sign
al in
dica
tor
Actu
ate c
omm
on su
perv
isory
sign
al
Actu
ate c
omm
on tr
oubl
e sig
nal i
ndic
ator
Actu
ate c
omm
on tr
oubl
e sig
nal
Actu
ate al
arm
indi
cato
r
Control Unit Annuciation
Butterfly Valve
Fire pump running
Fire pump power failure phase reversalFire alarm ac power failure
Fire alarm system low battery
Open circuit
Ground fault
Notification
Disp
lay p
rint c
hang
e of
statu
s
Tran
smit
fire
alarm
sign
al to
supe
rvisi
ng st
ation
Tran
smit
supe
rviso
ry si
gnal
to su
perv
ising
staio
n
Tran
smit
troub
le si
gnal
to su
perv
ising
stati
on
Required Fire Safety Control
Clos
ed sm
oke
/ fire
doo
r in
rate
d wa
lls
Actu
ate b
asem
ent e
xhau
st (if
any)
Unlo
ck e
xit
Supplementary
Actu
ate g
raph
ics s
yste
m -
disp
lay fl
oor m
ap
Pres
suriz
ing
stairw
ells
Shut
down
fres
h air
syste
mSh
utdo
wn E
xhau
st Fa
nsh
utdo
wn F
CU
1
2
U
System Input
System Output
4
6
7
8
9
10
11
12
3
Activ
ate V
oice
Eva
cuati
on
L
Multisensor Detector
5
Shut
down
Lift
P
Manual Pull Station -GF,1F,2F,3F
Smoke Detector -GF,1F,2F,3F & Roof Floor
Heat Detector-GF,1F,2F,3F
1 2
FF
E
D
A
C
B
1
3 4 5 6 7 8
E
D
32 4 5 6 7
A
C
B
8
FACTORY NAMEDRAWING TITLE DATE & PAGE NO.
7th January 2018A
REV.CONSULTANT NAME CHECKED BYDESIGNED BY
Addressable Fire Detection &Alarm System
SEAL & SIGNATURE
Engr. Md. Arif Hossain
B.Sc in EEE
HOUSE # 09, ROAD # 03, NIKUNJO-2,
KHILKHET DHAKA-1229
E-mail:[email protected]
KiK-UCEP Hasemuddin School.Plot # 07, Road # 05, Block # B
Sat Mosjid Housing, Beribandh, Mohammadpur,Dhaka-1207
Engr.Md. Ibrahim Khalil
B.Sc in EEE
Notification appliance circuit short-GF,1F,2F,3F
TE/UCEP/FDS/12