Kidde Fire Protection SystemsDual Spectrum® Optical Infrared Sensor Model PM-3MT
Dual spectrum infrared sensors detect fuel explosions and fires in enclosed spaces of armored personnel carriers. They are operational in any lighting condition and effective through oil, smoke, dirt and other obscurants.
These sensors evaluate the growth level of the fire event. By determining the rate of fire growth, fire protection system sensors are able to mitigate false alarms.
UTC Aerospace Systems provides fire and explosion sensors that utilize a patented infrared detection concept. These sensors respond to explosive fires in milliseconds and have excellent false alarm immunity.
Features
• Evaluate the growth level of the fire
• Excellent false alarm immunity
• Effective in obscurant environment
• Responds to explosive fires in milliseconds
For additional information: 4200 Airport Drive, Wilson, NC 27896 U.S.A. Tel: +1 252 246 7004 Fax: +1 252 246 7180
This document does not contain any export controlled technical data.
Kidde Fire Protection SystemsDual Spectrum® Optical Infrared Sensor Model PM-3MT
Performance Specifications
Sensitivity ThresholdFuels Size DistanceMethanol 1’ x 1’ pan 3 feetGasoline 1’ x 1’ pan 42 inchesDiesel Fuel 1’ x 1’ pan 42 inchesMethane 30” plume, 3/8” orifice 20 inchesHydrogen 30” plume, 3/8” orifice 12 inches
Typical System Layout
False Alarm Immunity
Stimulus Distance (in.)Sunlight NR
Bright colored clothing NR
Flashlight NR
Fluorescent light (40 watt) NR
Indirect or reflected light NR
Chopped light (vent fans, hatch covers, etc) NR
Electronic flash 1
Electric arc (1/2 in. 4000V) 1
Lit cigarette 1
Incandescent lamp (75 watts – rough surface) 2
Bookmatch flare-up 2
Large wooden match flare-up 4
Red dome light 1
Rifle flash (M16) 2
Vehicle headlights 6
Vehicle IR lights 12
NR = No response