2
Kidde Fire Protection Systems Dual Spectrum ® Optical Infrared Sensor Model PM-3MT Dual spectrum infrared sensors detect fuel explosions and fires in enclosed spaces of armored personnel carriers. They are operational in any lighting condition and effective through oil, smoke, dirt and other obscurants. These sensors evaluate the growth level of the fire event. By determining the rate of fire growth, fire protection system sensors are able to mitigate false alarms. UTC Aerospace Systems provides fire and explosion sensors that utilize a patented infrared detection concept. These sensors respond to explosive fires in milliseconds and have excellent false alarm immunity. Features Evaluate the growth level of the fire Excellent false alarm immunity Effective in obscurant environment Responds to explosive fires in milliseconds For additional information: 4200 Airport Drive, Wilson, NC 27896 U.S.A. Tel: +1 252 246 7004 Fax: +1 252 246 7180 This document does not contain any export controlled technical data.

Kidde Fire Protection Systems Dual Spectrum Optical ... Fire Protection Systems... · Kidde Fire Protection Systems Dual Spectrum® Optical Infrared Sensor Model PM-3MT ... and have

Embed Size (px)

Citation preview

Page 1: Kidde Fire Protection Systems Dual Spectrum Optical ... Fire Protection Systems... · Kidde Fire Protection Systems Dual Spectrum® Optical Infrared Sensor Model PM-3MT ... and have

Kidde Fire Protection SystemsDual Spectrum® Optical Infrared Sensor Model PM-3MT

Dual spectrum infrared sensors detect fuel explosions and fires in enclosed spaces of armored personnel carriers. They are operational in any lighting condition and effective through oil, smoke, dirt and other obscurants.

These sensors evaluate the growth level of the fire event. By determining the rate of fire growth, fire protection system sensors are able to mitigate false alarms.

UTC Aerospace Systems provides fire and explosion sensors that utilize a patented infrared detection concept. These sensors respond to explosive fires in milliseconds and have excellent false alarm immunity.

Features

• Evaluate the growth level of the fire

• Excellent false alarm immunity

• Effective in obscurant environment

• Responds to explosive fires in milliseconds

For additional information: 4200 Airport Drive, Wilson, NC 27896 U.S.A. Tel: +1 252 246 7004 Fax: +1 252 246 7180

This document does not contain any export controlled technical data.

Page 2: Kidde Fire Protection Systems Dual Spectrum Optical ... Fire Protection Systems... · Kidde Fire Protection Systems Dual Spectrum® Optical Infrared Sensor Model PM-3MT ... and have

Kidde Fire Protection SystemsDual Spectrum® Optical Infrared Sensor Model PM-3MT

Performance Specifications

Sensitivity ThresholdFuels Size DistanceMethanol 1’ x 1’ pan 3 feetGasoline 1’ x 1’ pan 42 inchesDiesel Fuel 1’ x 1’ pan 42 inchesMethane 30” plume, 3/8” orifice 20 inchesHydrogen 30” plume, 3/8” orifice 12 inches

Typical System Layout

False Alarm Immunity

Stimulus Distance (in.)Sunlight NR

Bright colored clothing NR

Flashlight NR

Fluorescent light (40 watt) NR

Indirect or reflected light NR

Chopped light (vent fans, hatch covers, etc) NR

Electronic flash 1

Electric arc (1/2 in. 4000V) 1

Lit cigarette 1

Incandescent lamp (75 watts – rough surface) 2

Bookmatch flare-up 2

Large wooden match flare-up 4

Red dome light 1

Rifle flash (M16) 2

Vehicle headlights 6

Vehicle IR lights 12

NR = No response

The Dual Spectrum® Automatic Fire Sensing and Suppression System will not false alarm at the distances indicated above, or greater and sensors are installed to avoid the environment located outside of the vehicle, except with regard to tire fire systems and similar.

utcaerospacesystems.com

4280A LIT 3/2016 © Kidde Technologies Inc., 2016

For additional information: 4200 Airport Drive, Wilson, NC 27896 U.S.A. Tel: +1 252 246 7004 Fax: +1 252 246 7180

This document does not contain any export controlled technical data.