8
KEK Test Results / Plans Akira SATO Osaka University, Japan

KEK Test Results / Plans Akira SATO Osaka University, Japan

  • View
    218

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KEK Test Results / Plans Akira SATO Osaka University, Japan

KEK Test Results / Plans

Akira SATO

Osaka University, Japan

Page 2: KEK Test Results / Plans Akira SATO Osaka University, Japan

contents

Cross talk of SCSF78 Fiber optimization KEK plan Attenuation length Beam test

Page 3: KEK Test Results / Plans Akira SATO Osaka University, Japan

Cross talk for SCSF78

Experimental data can be explained assuming that mean free path of primary photon is 460m.

1.0GeV/c

1.0GeV/c

proton/p ratio

300m 0.5 p.e. 0.8 p.e. 0.68

500m 1.2 p.e. 1.6 p.e. 0.75

dE/dx1.8

MeV/cm

2.6

MeV/cm0.7

Sci-Fi

Primary photon

1.0GeV/c

1.0GeV/c

proton

300m 1.92 p.e. 2.77 p.e.

500m 2.92 p.e. 4.21 p.e.

300m 0.55 p.e. 0.80 p.e.

500m 1.20 p.e. 1.72 p.e.

Experimental data

Expected # of p.e. with 0m MFP

Expected # of p.e. with 460m MFP

From last KEK beam test results

Page 4: KEK Test Results / Plans Akira SATO Osaka University, Japan

Optimization of 3HF fiber Alan estimated the mean-free path (MFP) for absorption by 3HF of th

e primary scintillation light from the primary dopant p-terphenyl (pT). The absorption can be expressed as

I/Io = 10-(cd)

: the molar extinction coeff. in (moles per liter-cm)-1 at wavelength c : the concentration in moles per liter

d : the distance in cm

Attenuation length for the primary dye emission via 3HF absorption : 50m for 1dye+3HF(1500 ) D0 tracker 21m for 1dye+3HF(3500) Very short for 3HF(5000) w/o 1dye

At high concentrations, 3HF acts like a primary dopant ie, its coupling the the fundamental PS excitation is quite strong.

Page 5: KEK Test Results / Plans Akira SATO Osaka University, Japan

KEK and Osaka Plan Scintillating fibers had been deriverd to Osaka Univ. June 3rd

Standard primary(pT) + 3HF(2500ppm) Standard primary + 3HF(3500ppm) Standard primary + 3HF(5000ppm) 3HF(5000ppm) only

0.35mm, round, multi-clad, s-type

We are planing to study : Attenuation length Aging of bending fiber Light yield (beam test) Cross talk (beam test)

Page 6: KEK Test Results / Plans Akira SATO Osaka University, Japan

Attenuation length Measurement has just started. Cracks in fiber reduce light yield. Need some quality control preliminarypreliminary

Page 7: KEK Test Results / Plans Akira SATO Osaka University, Japan

KEK beam test June 25th - July 2nd @ KEK 2 beam line Photon detector

Hamamatsu R7899 MOD Extended Green Photocathode 1 inch diameter 10 stage Head-on Type Prismatic Window

Light yield Cross talk

Sci-Fi

PMT (R7899)

Page 8: KEK Test Results / Plans Akira SATO Osaka University, Japan

summary

The most suitable fiber for MICE scifi tracker will be selected by KEK studies.Candidates : Standard primary(pT) + 3HF(2500ppm) Standard primary + 3HF(3500ppm) Standard primary + 3HF(5000ppm) 3HF(5000ppm) only

Attenuation length Aging Light yield Cross talk

Beam test : June 25th - July 2nd @ KEK-PS 2