LED CONVERSION KITS KCK445R SOL-LUX The King Luminaire KCK445R Sol-Lux LED Conversion Kit offers a simple way to convert to high efficiency LED. Through Tri-Thermal Management, the KCK445R Sol-Lux reduces heat via convection, radiation and conduction for a long operational life. This conversion kit is a complete fully tested system that requires little maintenance. LIGHTING THE WAY ® Features - Complete system that includes a new globe, LED light engine and driver assembly - T1 optical system with COB LED Technology - CCT of 3000 & 4000K (+/- 300K), minimum 70 CRI - Type IV and V IESNA distribution patterns - Efficacy up to 141 lumens/watt - Certified to UL standards and UL wet listed - 7 year warranty Benefits - Easy installation of a complete, fully tested system - Absolute photometry and accurate lighting layouts - Long operational life with Tri-Thermal Management consisting of convection, radiation and conduction - Higher light quality and control than Retrofits - Impressive lumen output and efficacy - Energy savings with reduced maintenance 11-18-2019 T1 LED ENGINE The T1 optical system simulates a pointed light source by utilizing highly efficent multi point Chip On Board (COB) LED emitters, reflectors and precision external optics. Optical System

KCK445R CONV KIT Spec Sheet NOV 2019 - scgrp.com€¦ · KCK445R CONV KIT Spec Sheet NOV 2019.indd Created Date: 11/29/2019 10:59:20 AM

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KCK445R CONV KIT Spec Sheet NOV 2019 - scgrp.com€¦ · KCK445R CONV KIT Spec Sheet NOV 2019.indd Created Date: 11/29/2019 10:59:20 AM

LED CONVERSION KITSKCK445R SOL-LUX

The King Luminaire KCK445R Sol-Lux LED Conversion Kit offers a simple way to convert to high efficiency LED. Through Tri-Thermal Management, the KCK445R Sol-Lux reduces heat via convection, radiation and conduction for a long operational life. This conversion kit is a complete fully tested system that requires little maintenance.

LIGHTING THE WAY ®

Features- Complete system that includes a new globe, LED light engine and driver assembly- T1 optical system with COB LED Technology- CCT of 3000 & 4000K (+/- 300K), minimum 70 CRI- Type IV and V IESNA distribution patterns- Efficacy up to 141 lumens/watt- Certified to UL standards and UL wet listed- 7 year warranty

Benefits- Easy installation of a complete, fully tested system- Absolute photometry and accurate lighting layouts- Long operational life with Tri-Thermal Management consisting of convection, radiation and conduction- Higher light quality and control than Retrofits - Impressive lumen output and efficacy- Energy savings with reduced maintenance

11-18-2019

T1LEDENGINE

The T1 optical system simulates a pointed light source by utilizing highly efficent multi point Chip On Board (COB) LED emitters, reflectors and precision external optics.

Optical System

Page 2: KCK445R CONV KIT Spec Sheet NOV 2019 - scgrp.com€¦ · KCK445R CONV KIT Spec Sheet NOV 2019.indd Created Date: 11/29/2019 10:59:20 AM

LIGHTING THE WAY ®

The number of market-ready LED products grows daily. Some perform very well and provide more than 50% energy savings, but the quality and energy efficiency vary widely. It is important to ensure you choose an LED system that meets industry standards. King Luminaire is committed to continue the tradition of produc-ing high performance and quality light systems that was started over 60 years ago.

KING LUMINAIRE’S CONVERSION KITS

LED ‘RETROFITS’ WHY IT’S IMPORTANT

Fully tested and certified as a whole sys-tem that includes globe, LED light engine and driver assembly.

Certification for outdoor lighting through CSA (UL) and IES.

Retrofit tested on its own as a compo-nent, not as a whole system.

Not always tested with CSA (UL) and IES.

It is important to test a system as a whole in order to accurately report on photomet-rics, lumen output and thermals. Certification through CSA (UL) and IES is very important, since it means the system has all the above information available and it meets the industry standard.

Absolute photometry and accurate light-ing layouts provided.

Cannot provide absolute photometry or accurate lighting layouts.

Light levels required may not be met with retrofits which may cause safety issues and require additional lights to be installed.

Fixture efficacy and delivered lumens reported as a whole system.

Retrofits report the efficacy and deliv-ered lumens as a component.

In order to accurately determine how an LED system will perform as a whole, the LED engine must be tested and installed in the intended fixture.

Lumen depreciation data, such as L70 as per TM-21, is provided for our system as a whole.

Retrofits do not report thermal infor-mation as a whole system only as a component.

In order to accurately calculate the lumen depreciation, and thereby the useful operating life of the fixture, it must be thermally tested as a whole system, not as a stand-alone compo-nent.

Incorporates dynamic thermal manage-ment for venting and sinking all our LED products.

Retrofits may have sinks, but typically fail to offer proper heat venting with airflow over heat sinks within the fixture.

If LED systems do not have proper venting and sinking there is risk of premature failure. Think of proper heat management as an insurance policy to protect your investment.

King conversion systems are easy to install with just 6 simple steps.

Retrofits can be quite complicated to install which can result in increased labor costs.

Due to the increased difficulty to install a retrofit, it can take much more time and may result in an installation error which could result in reduced system performance or premature failure.

IP66 certified as a whole system which means the optical chamber is sealed, so moisture, dirt, bugs or any other small objects will not be able to penetrate.

The retrofit as a component may be IP66 certified, but the system as a whole is not. This means dirt, bugs or other small objects may get into the optical chamber.

If foreign materials enter the optical chamber it can cause greatly reduced lumen output. Dirt build-up can cause an increase in heat which will reduce performance or create failure. Mois-ture can be very adverse and also cause failure.

Standard 7 year warranty on our LED sys-tems with Gold Standard customer service to provide support on our products long into the future.

Retrofit companies will warranty the component, but not the system as a whole.

It is important to warranty the full system with a company who has been in the business of manufacturing outdoor lighting for over 20 years.

LED CONVERSION KITSKCK445R SOL-LUX

CONVERSION KITS VS RETROFITSCONVERSION KITS VS RETROFITS

Page 3: KCK445R CONV KIT Spec Sheet NOV 2019 - scgrp.com€¦ · KCK445R CONV KIT Spec Sheet NOV 2019.indd Created Date: 11/29/2019 10:59:20 AM

PRODUCT SPECIFICATIONSPRODUCT SPECIFICATIONSLED ENGINEThe light engine shall be an ar-ray of 4 or 6 Cree Chip On Board (COB) diodes mounted to a high-ly conductive aluminum extrusion with the use of 2 electrical con-nectors. The aluminum extrusion will be mechanically attached to a thermal heat sink at both the top and bottom of the aluminum extrusion. It shall remain in ther-mal contact to the heat sinks with the use of conductive silicone. There will be an aluminum uplight reflector in both Type IV & Type V IESNA distribution patterns.

REFRACTIVE GLASS GLOBEThe glass globe shall be made of 9018 clear borosilicate glass having a minimum thickness of 0.300” with an overall diameter of 13.5” and an over-all height of 19.25”. It will be designed for op-timum optical efficiency and light control.

The glass globe is secured to the luminaire body by means of a split-clamping ring of durable cast A319 aluminum, which al-lows easy, tool-less removal of the globe assembly from the lu-minaire body by means of King Luminaire’s Rotolock™ system.

A minimum ingress protection against water or dust particles of IP66 for the LED optical cham-ber is provided by non-porous, closed-cell silicon rubber sponge gasketing which is highly effi-cient in sealing against particle ingress for a wide temperature range (-40°F to 310°F).

DRIVERCSA certified and/or UL listed, electronic programmable, Con-stant Light Output (CLO) driv-er with a 0-10v dimming lead. Driver shall supply correct DC voltage and current to maintain proper operation of the emitters. The driver shall be UL1310/UL48 Class 1 certified, and contain over-circuit, over-voltage, and over-power protection. An in-line ferrite choke is utilized to provide protection against EFT’s. The multi-volt driver shall be capable to connect to AC input voltages of 120V - 277V or 347 - 480V. The driver shall have a minimum life expectancy of 100,000 hrs with a case temperature range of -40°C

to a maximum of 60°C. The driv-er casing shall have a minimum ingress protection rating of IP67. PHOTOMETRICSFixtures are tested to IESNA LM79 specifications. These re-ports are available upon request.

CHROMATICITYHigh output COB LEDs come standard at 3000K & 4000K (+/- 300K) with a minimum nominal 70 CRI. Additional CCT emitters are available upon request.

LUMEN MAINTENANCEReported (TM21) and Calculated (L70) reports are available upon request with a minimum calcu-lated value of 100,000 hrs.

WIRINGAll internal wiring and connec-tions shall be completed so that it will be necessary only to attach the incoming supply connectors to Mate-N-Lok connectors or to a terminal block. Mate-N-Lok shall be certified for 600V operation. Internal wire connectors shall be crimp connector only and rated at 1000V and 150°C. All wiring to be CSA certified and/or UL listed, type SFF-2, SEWF-2, or SEW-2 No. 14 gauge, 150°C, 600V, and color coded for the required volt-age.

THERMALSFixtures tested to determine the maximum in-situ case tempera-ture of the LED emitters as rec-ommended by Cree. This report is available upon request.

FINISHHousing is finished with a 13 step KingCoat™ SuperDurable poly-ester TGIC powder coat. Stan-dard colors include strobe white, brown metal, marina blue, gate gray, Chicago bronze, standard gold, standard black, federal green and rain forest. Please see our website for a complete list of colors. Additional RAL or custom color matches are available.

MISCELLANEOUSAll exterior hardware and fas-teners, wholly or partly exposed, shall be stainless steel alloy. All internal fasteners are stainless steel or zinc coated steel. All remaining internal hardware is

stainless steel, aluminum alloy, or zinc coated steel.

WARRANTYThe KCK445 Sol-Lux LED con-version kit comes with a 7 year limited warranty.

CERTIFICATION:

CSA US Listed Suitable for wet locationsISO 9001 IP66ARRA CompliantLM79 / LM80 Compliant

DRIVER INFO:

>0.9 Power Factor<20% Total Harmonic Distortion 120 - 277V & 347 - 480V-40°C Min. Case Temperature60°C Max. Case TemperatureSurge Protection: ANSI C136.2 extreme level 20kV/10kA

LED CONVERSION KITSKCK445R SOL-LUX

Page 4: KCK445R CONV KIT Spec Sheet NOV 2019 - scgrp.com€¦ · KCK445R CONV KIT Spec Sheet NOV 2019.indd Created Date: 11/29/2019 10:59:20 AM

HOW TO ORDERHOW TO ORDER KCK445R SOL-LUX LED CONVERSION KIT

KCK445R

LUMINAIRE STYLE

KCK445R - Sol-Lux

OPTICAL OPTIONS

T1GR - T1 Optic (Tower Array) Glass Refractor

IES LIGHTINGCLASSIFICATION

IV - Type 4V - Type 5

SOURCE

SSL - Solid State

4004 (4 COB, Type IV)4006 (6 COB, Type V)

SERIES

WATTAGE

40, 60, 75, 100 120V (120-277)480V (347-480)*

*Select wattagesavailable whithinthis range, contactKing Luminaire

LINE VOLTAGE

DECORATIVE OPTIONS

SST - Solid Spun Aluminum Top

- - - (SSL) - - -

PAINT COLOR

GN - Federal GreenBE - Blue

GY - GrayBN - BrownBK - BlackBZ - Bronze

*Additional options

available on website

-

FINIAL OPTIONS

#1, #2, #3

*Additional optionsavailable on website

-

TB - Terminal Block

CONNECTION

*leave blank if terminal block is not required

-

CCT

3K - 3000K4K - 4000K

STEP 2:Remove the globe from the HID fixture

STEP 3:Remove the ballast plate and assembly from the HID fixture

STEP 4:Unplug the HID power leads from the ballast assembly

STEP 5:Connect the LED power leads

STEP 6:Place the LED conversion kit globe on the capital and Rotolock™ it into place or engage the set screws if a non Rotolock™ globe is provided

STEP 1:Determine the HID fixture you wish to convert to LED

CONVERSION COMPLETE