Upload
lephuc
View
223
Download
0
Embed Size (px)
Citation preview
www.detectomat.com
contents
page
1. fire control panels1.1 detect 3004 fire control panel and accessories ...............................................................................................................4-111.2 detect 3016 fire control panel and accessories .............................................................................................................12-171.3 detect 3004/3016 panel accessories ............................................................................................................................18-231.4 network components ....................................................................................................................................................24-281.5 programming tools and software ...................................................................................................................................29-301.6 visualization .................................................................................................................................................................31-321.7 conventional panels ...........................................................................................................................................................32
2. detectors2.1 loop3000 – adressable detectors..................................................................................................................................33-392.2 CT 3000 – conventional detectors .................................................................................................................................39-422.3 detector accessoires.....................................................................................................................................................43-48
3. manual call points3.1 loop3000 – addressable manual call points ..................................................................................................................49-523.2 CT 3000 – conventional call points ...............................................................................................................................52-543.3 accessoires for manual call points......................................................................................................................................55
4. loop3000 modules ......................................................................................................................................................56-58
5. loop3000 – radio extension ........................................................................................................................................59-61
6. special detectors6.1 aspiration smoke detectors ...........................................................................................................................................62-656.2 accessoires smoke detectors ........................................................................................................................................66-696.3 infrared beam detectors................................................................................................................................................70-716.4 sensor cable detectors .......................................................................................................................................................726.5 flame detectors ............................................................................................................................................................73-756.6 intrisically safe detectors ..............................................................................................................................................75-78
7. home smoke detectors ...............................................................................................................................................79-82
8. signalling devices8.1 signalling devices for loop3000 ....................................................................................................................................83-858.2 conventional signalling devices .....................................................................................................................................85-90
9. door magnets and accessoires...................................................................................................................................91-95
10. detector testing devices .............................................................................................................................................96-97
11. Article index .............................................................................................................................................................98-103
12. Terms & Conditions of Sale detectomat GmbH .......................................................................................................104-106
Produktaktualisierungen finden Sie Stand August 2006 laufend unter www.detectomat.de
www.detectomat.com
4
1.1 detect 3004 fire control panel and accessories
1. fire control panels
fire control panel detect 3004art. 31973
Microprocessor controlled modular fire control panel DIN EN 54,VDE 0833 and VdS approved. For use with the loop3000 fire detection system components.
• display- and control panel DIN EN 54 part 2• 4 alphanumeric lines LCD- display with backlight • 2 slots for detector interface boards (max. to equip up to 4 loops
or 16 conventional fire zones)
• 2 slots for fire brigade and network interface • 128 programmable detector zones• up to 4 x 126 loop3000 components• up to 16 inputs for conventional detector zones • maximum loop length 3.000 m (using installation cable
IY(St)Y 2 x 0,8 mm)• monitored loop operation with detection system loop3000• facility for integration of fire brigade interface, display panel,
transmission- and key-depot adapter interface • 3 potential-free relay outputs (250 V / 5 A)• 9 open collector outputs (30 V / 90 mA)• monitored signal transmitter 400 mA• 2 RS 232 interfaces for personal computer, printer, modem,
building management system• network compatible via bitbus interface up to 32 fire control
panels controls or additional 63 bitbus components• operation and event memory for 500 messages (first in first
out principle)• possibility via mounting panel to integrate a protocol-printer and
LED indicator modules for zone alarm and zone fault indication• option to equip a redundant main board processor (second CPU)• power supply 72 W and monitored battery condition• storing space for two batteries 12 V / 26 Ah
technical specification
input voltage 230 V AC (-15 % / +10%)frequency 50 / 60 Hzoperation voltage 21,0 up to 29,2 V DCpower supply 72 Wemergency power max. 2 x 12 V / 26 Ahquiesent current 86 mAalarm current 146 mAinterfaces 2 x RS 232/422 Bitbus (option)display LCD 4 x 20 characterszone LED´s poss. for up to 48 zone indicators sounder output 24 V DC / 400 mA monitoredexternal user output 24 V DC / 800 mA relay output 3 change over 250 V / 5 Aopen collector output 9 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Chumidity up to 95 % protection class IP 30housing color light grey, RAL 7035front color tele grey, RAL 7046material sheet steelweight 12,5 kgdimensions (H x W x D) 490 mm x 420 mm x 210 mmapprovals VdS: G 203068, S 295054, LPCB,
GOST, Hungary, Bulgaria, Lithuania,Czech Republik, Ukrain, Slovakia,Slovenia, Spain, Switzerland, Belgium
complies with EN 54 - 2
remarks: if you use a printer 30106 you can use only 18 ah- orsmaller batteries
www.detectomat.com
5
1.1 detect 3004 fire control panel and accessories
1. fire control panels
fire control panel shallow detect 3004 - shallowart. 31972
Microprocessor controlled modular fire control panel, shallow version, DIN EN 54, VDE 0833 and VdS approved. For use with the loop3000 fire detection system components.
• display- and control panel DIN EN 54 part 2• 4 alphanumeric lines LCD- display with backlight • 2 slots for detector interface boards (max. to equip up to 4 loops
or 16 conventional fire zones)
• 2 slots for fire brigade and network interface • 128 programmable detector zones• up to 4 x 126 loop3000 components• up to 16 inputs for conventional detector zones • maximum loop length 3.000 m (using installation cable
IY(St)Y 2 x 0,8 mm)• monitored loop operation with detection system loop3000• facility for integration of fire brigade interface, display panel,
transmission- and key-depot adapter interface • 3 potential-free relay outputs (250 V / 5 A)• 9 open collector outputs (30 V / 90 mA)• monitored signal transmitter 400 mA• additional external output 24V / 800mA• 2 RS 232 interfaces for personal computer, printer, modem,
building management system• network compatible via bitbus interface up to 32 fire control
panels or additional 63 bitbus components• operation and event memory for 500 messages (first in first
out principle)• possibility via mounting panel to integrate a protocol-printer and
LED indicator modules for zone alarm and zone fault indication• option to equip a redundant main board processor (second CPU)• power supply 72 W and monitored battery condition• storing space for two batteries 12 V / 12 Ah
technical specification
input voltage 230 V AC (-15 % / +10%)frequency 50 / 60 Hzoperation voltage 21,0 up to 29,2 V DCpower supply 72 Wemergency power max. 2 x 12 V / 26 Ahquiesent current 86 mAalarm current 146 mAinterfaces 2 x RS 232/422 Bitbus (option)display LCD 4 x 20 characterszone LED´s poss. for up to 48 zone indicators sounder output 24 V DC / 400 mA monitoredexternal user output 24 V DC / 800 mA relay output 3 change over 250 V / 5 Aopen collector output 9 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Chumidity up to 95 % protection class IP 30housing color light grey, RAL 7035front color tele grey, RAL 7046material sheet steelweight 12,5 kgdimensions (H x W x D) 490 mm x 420 mm x 150 mmapprovals VdS: S 295054, LPCB, GOST,
Hungary, Bulgaria, Lithuania, Czech Republik, Ukrain, Slovakia, Slovenia,Spain, Switzerland, Belgium
complies with EN 54 - 2
remarks: usable as master remote and control panel in a network withthe language kit LK ABF, this version of the remote and control paneloffers space for LED indicators, printer, separate power supply etc
www.detectomat.com
6
1.1 detect 3004 fire control panel and accessories
1. fire control panels
fire control panel 19" rack mount detect 3004-19"art. 32049
Microprocessor controlled modular fire control panel,19" rack mount version, DIN EN 54, VDE 0833 and VdS approved.For use with the loop3000 fire detection system components.
• display- and control panel DIN EN 54 part 2• 4 alphanumeric lines LCD- display with backlight • 2 slots for detector interface boards (max. to equip up to 4 loops
or 16 conventional fire zones)• 2 slots for fire brigade and network interface • 128 programmable detector zones• up to 4 x 126 loop3000 components• up to 16 inputs for conventional detector zones • maximum loop length 3.000 m (using installation cable
IY(St)Y 2 x 0,8 mm)• monitored loop operation with detection system loop3000• possibility for integration of fire brigade interface, display panel,
transmission- and key-depot adapter interface • 3 potential-free relay outputs (250 V / 5 A)• 9 open collector outputs (30 V / 90 mA)• monitored signal transmitter 400 mA• additional external output 24V / 800mA• 2 RS 232 interfaces for personal computer, printer, modem,
building management system
• network compatible via bitbus interface up to 32 fire panel controls or additional 63 bitbus components
• operation and event memory for 500 messages (first in first out principle)
• suitable for 19" rack mount• option to equip a redundant main board processor (second CPU)• power supply 72 W and monitored battery condition
technical specification
input voltage 230 V AC (-15 % / +10 %)frequency 50 / 60 Hzoperation voltage 21,0 up to 29,2 V DCpower supply 72 Wemergency power max. 2 x 12 V / 26 Ahquiesent current 86 mAalarm current 146 mAinterfaces 2 x RS 232/422 Bitbus (option)display LCD 4 x 20 characterszone LED´s poss. for up to 48 zone indicators sounder output 24 V DC / 400 mA monitoredexternal user output 24 V DC / 800 mA relay output 3 change over 250 V / 5 Aopen collector output 9 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Chumidity up to 95 % protection class IP 30front color tele grey, RAL 7046dimensions (H x W x D) 6HE x 19" x 150 mmapprovals VdS: G 203068, S 295054, LPCB,
GOST, Hungary, Bulgaria, Lithuania,Czech Republik, Ukrain, Slovakia,Slovenia, Spain, Switzerland, Belgium
complies with EN 54 - 2
remarks:• the panel is designed to be mounted in a 19"- rack • the power pack is separately mounted in the 19"- rack• additional space is required for battery storage
language kit German LK 3004 D
language kit integrates German software, German description,German labelling
remarks: it is essential to specify the language kit when ordering
art. 31974
language kit English LK 3004 GB
language kit integrates English software, English description,English labelling, additional languages available on request
remarks: it is essential to specify the language kit when ordering
art. 31975
www.detectomat.com
7
1.1 detect 3004 fire control panel and accessories
1. fire control panels
1-loop interface DLI 3240 X1-1L
picture similar
to plug in to the detect 3004 fire control panel for max. 126 loop3000 components
• maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm)• all loop3000 components can be addressed automatically• manual addressable with EasyCheck 3000 (31482) • two - wire - loop• 8 freely programmable open collector outputs• 3 open collector outputs 30 V DC / 90 mA for alarm and fault• loop voltage 32 V DC, loop current 100 mA • RS 232 interface for additional data monitoring• slot for optional redundant processor
technical specification
operation voltage 20 up to 28 V DCquiesent current 40 mAalarm current max. 100 mAinterfaces RS 232open collector output 11 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Cweight 200 gdimensions (H x W x D) 140 mm x 140 mm x 30 mm
remarks: use the current version of the loop calculator to determinthe maximum number of loop devices/components and mix
art. 31817
2-loop interface DLI 3240 X1-2L
to plug in to the detect 3004 fire control panel for max. 2x126 loop3000 components
• maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm)• all loop3000 components can be addressed automatically• manual addressable with EasyCheck 3000 (31482) • two - wire - loop• 8 freely programmable open collector outputs• 3 open collector outputs 30 V DC / 90 mA for alarm and fault• loop voltage 32 V DC, loop current 100 mA per loop• RS 232 interface for additional data monitoring• slot for optional redundant processor
technical specification
operation voltage 20 up to 28 V DCquiesent current 40 mAalarm current max. 2 x 100 mAinterfaces RS 232open collector output 11 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Cweight 200 gdimensions (H x W x D) 140 mm x 140 mm x 30 mm
remarks: use the current version of the loop calculator to determinthe maximum number of loop devices/components and mix
art. 30209
www.detectomat.com
8
1.1 detect 3004 fire control panel and accessories
1. fire control panels
2-loop interface active DLI 3240 P X1
picture similar
to plug in to the detect 3004 fire control panel for max. 2x126 loop3000 components
• maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm)• all loop3000 components can be addressed automatically• manual addressable with EasyCheck 3000 (31482) • two - wire - loop• 8 freely programmable open collector outputs• 3 open collector outputs 30 V DC / 90 mA for alarm and fault• loop voltage 32 V DC, loop current 140 mA per loop• RS 232 interface for additional data monitoring• slot for optional redundant processor
technical specification
operation voltage 20 up to 28 V DCquiesent current 40 mAalarm current max. 2 x 140 mAinterfaces RS 232open collector output 11 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Cweight 200 gdimensions (H x W x D) 140 mm x 140 mm x 30 mm
remarks: use the current version of the loop calculator to determinthe maximum number of loop devices/components and mix
art. 32098
2-loop interface redundant CP DLI 3240 X1-R
to plug in to the detect 3004 fire control panel for max. 2x126 loop3000 components
• maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm)• all loop3000 components can be addressed automatically• manual addressable with EasyCheck 3000 (31482) • two - wire - loop• 8 freely programmable open collector outputs• 3 open collector outputs 30 V DC / 90 mA for alarm and fault• loop voltage 32 V DC, loop current 100 mA per loop• RS 232 interface for additional data monitoring• redundant second processor for emergency operation
technical specification
operation voltage 20 up to 28 V DCquiesent current 40 mAalarm current max. 2 x 100 mA interfaces RS 232open collector output 11 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Cweight 200 gdimensions (H x W x D) 140 mm x 140 mm x 30 mm
remarks: use the current version of the loop calculator to determinthe maximum number of loop devices/components and mix
art. 31312
www.detectomat.com
9
1.1 detect 3004 fire control panel and accessories
1. fire control panels
conventional interface for 8 fire zones CP CLI X1
to plug in to the detect 3004 fire control panel for max. 8 conventional fire zones
• maximum 25 conventional detectors per fire zone connectable• 8 freely programmable open collector outputs 30 V DC / 90 mA• 3 open collector outputs 30 V DC / 90 mA• slot for optional redundant processor
technical specification
operation voltage 20 up to 28 V DCalarm current 85 mA + 50 mA per zone outputopen collector output 11 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Cweight 200 gdimensions (H x W x D) 140 mm x 140 mm x 30 mm
art. 30210
ground circuit module CP EM
to plug in to the detect 3004 fire control panel for monitoring of the galvanic separation between ground potential and all secundaryvoltages e.g. fire zone, monitoring outputs
technical specification
operation voltage 18 up to 30 V DCquiesent current 7 mAopen collector output fault output voltage: max 29 V
fault output current: max. 0,1 Aoperation temperature -5°C up to +50°Cfront color greenmaterial polyamid PA6.6weight 50 gdimensions (H x W x D) 59 mm x 20 mm x 60 mm
art. 30927
LED indicator modul CP ZM 8
two LED indicators for 8 zones per modul to plug into the fire controlpanel detect 3004 for zone alarm and zone fault indication
• 1 red and 1 yellow LED per fire zone• 8 fire zones on 1 modul
technical specification
alarm current 3 mA per zoneoperation temperature -5°C up to +40°Cdimensions (H x W) 93 mm x 80 mm
remarks: a maximum of 6 LED indicator modules are available,an adapter plate 30386 is required for more than 16 zones
art. 30088
www.detectomat.com
10
1.1 detect 3004 fire control panel and accessories
1. fire control panels
mounting plate CP MP 3004
expansion mounting plate to plug in to the detect 3004 fire controlpanel front for up to 6 LED indicator modules or / and protocol printerincluding front foil
• mounting plate for maximum 6 LED indicator modules • provides facility for protocol printer 30099 or 30106• zones can be identified by labelling
technical specification
operation temperature -5°C up to +40°Cdimensions (H x W) 228 mm x 365 mm
remarks: installation into the detect 3004 fire control panel possible
art. 31946
extinguishing control modul CP ETB X1
plug in extinguishing control module for the detect 3004 fire panelto control one extinguishing area
• direct activation of the extinguishing area valves• 4 monitored control lines for signal transmitter and solenoid valves• activation from loop or conventional interface
technical specification
operation voltage 20 up to 28 V DCquiesent current 45 mAalarm current 60 mA + 1 A per outputsounder output 4 x 24 V DC / 1 A monitoredexternal user output 4 x 24 V DC / 1 A monitoredoperation temperature -5°C up to +40°Cdimensions (H x W x D) 140 mm x 140 mm x 20 mm
remarks: an additional extinguishing panel is not necessary
art. 30111
adapter for LED indicator modul CP ADB 48
to plug into the detect 3004 fire conrol panel more than two LEDindicator modules 30088
technical specification
operation temperature -5°C up to +40°Cdimensions (H x W) 55 mm x 108 mm
remarks: a maximum of 6 alarm indicator zones available,adapter plate 30386 irequired after 16 zones
art. 30386
www.detectomat.com
11
1.1 detect 3004 fire control panel and accessories
1. fire control panels
redundant main board processor CP CPU X1-R
to plug in to the detect 3004 fire panel to duplicate the main board processor
• takes over the control in case of CPU-failure
technical specification
approvals VdS G 203 068
art. 30113
universal expansion housing UZG-1
provides additional space for ancilary components
• sheet steal housing compatible with fire control panel detect 3004• lock for door
technical specification
protection class IP 30housing color light grey, RAL 7035front color tele grey, RAL 7046material sheet steelweight 5 kgdimensions (H x W x D) 490 mm x 420 mm x 210 mm
art. 31318
www.detectomat.com
12
1.2 detect 3016 fire control panel and accessories
1. fire control panels
fire control panel detect 3016art. 31989
Microprocessor controlled modular fire control panel DIN EN 54, VDE 0833 and VdS approved. For use with the loop3000 fire detectionsystem components.
• display- and control panel DIN EN 54 part 2• 4 alphanumeric lines LCD- display with backlight • the basic version offers 5 slots for detector interface boards
and 1 slot for OC - boards
• additional two extension with 2+1 slots connectable (max. to equip up to 16 loops or 64 conventional fire zones)
• 2 slots for fire brigade and network interface • 192 programmable detector zones• up to 16 x 126 loop3000 components• up to 64 conventional fire zones • maximum loop length 3.000 m (using installation cable
IY(St)Y 2 x 0,8 mm)• monitored loop operation with detection system loop3000• integrated fire brigade interface for control of display panel,
transmission- and key-depot adapter interface • 3 potential-free relay outputs (250 V / 5 A)• 9 open collector outputs (30 V / 90 mA)• monitored signal transmitter 400 mA• 2 additional external outputs 24V / 800mA• 2 RS 232 interfaces for personal computer, printer, modem,
building management system• network compatible via bitbus interface up to 32 fire control
panels or additional 63 bitbus components• operation and event memory for 500 messages (first in first
out principle)• possibility via mounting panel to integrate a protocol-printer and
LED indicator modules for zone alarm and zone fault indication• option to equip a redundant main board processor (second CPU)• power supply 192 W and monitored battery condition• storing space for two batteries 12 V / 45 Ah
technical specification
input voltage 230 V AC (-15 % / +10%)frequency 50 / 60 Hzoperation voltage 21,0 up to 29,2 V DCpower supply 192 Wemergency power max. 2 x 12 V / 45 Ahinterfaces 2x RS 232/422 Bitbus (option)display LCD 4 x 20 characterszone LED´s poss. for up to 192 zone indicatorssounder output 24 V DC / 400 mA monitoredexternal user output 2 x 24 V DC / 800 mA relay output 3 change over 250 V / 5 Aopen collector output 9 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Chumidity max. 95 %protection class IP 30housing color light grey, RAL 7035front color tele grey, RAL 7046material sheet steelweight 30,0 kgdimensions (H x W x D) 750 mm x 600 mm x 240 mmapprovals VdS: G 203067, S 295054, LPCB,
GOST, CCC, Hungary, Bulgaria,Lithuania, Czech Republik, Ukrain,Slovakia, Slovenia, Spain,Switzerland, Belgium
complies with EN 54 - 2
remarks: if you use a printer 30106 you can use only up to 5 LEDindicator modules for 160 fire zones
www.detectomat.com
13
1.2 detect 3016 fire control panel and accessories
1. fire control panels
fire control panel 19" rack mount detect 3016-19"art. 31990
language kit German LK 3016 D
language kit integrates German software, German description,German labelling
remarks: it is essential to specify the language kit when ordering
art. 31991
language kit English LK 3016 GB
language kit integrates English software, English description,English labelling, additional languages available on request
remarks: it is essential to specify the language kit when ordering
art. 31992
Microprocessor controlled modular fire control panel,19" rack mount version, DIN EN 54, VDE 0833 and VdS approved.For use with the loop3000 fire detection system components.
• display- and control panel DIN EN 54 part 2• 4 alphanumeric lines LCD- display with backlight • the basic version offers 5 slots for detector interface boards and
1 slot for OC - boards• additional two extension with 2+1 slots connectable
(max. to equip up to 16 loops or 64 conventional fire zones)• 2 slots for fire brigade and network interface • 192 programmable detector zones• up to 16 x 126 loop3000 components• up to 64 conventional fire zones • maximum loop length 3.000 m (using installation cable
IY(St)Y 2 x 0,8 mm)• monitored loop operation with detection system loop3000• integrated fire brigade interface for control of display panel,
transmission- and key-depot adapter interface • 3 potential-free relay outputs (250 V / 5 A)• 9 open collector outputs (30 V / 90 mA)• monitored signal transmitter 400 mA• 2 additional external outputs 24V / 800mA• 2 RS 232 interfaces for personal computer, printer, modem,
building management system• network compatible via bitbus interface up to 32 fire control
panels or additional 63 bitbus components
• operation and event memory for 500 messages (first in first out principle)
• suitable for 19" rack mount• possibility via mounting panel to integrate a protocol-printer and
LED indicator modules for zone alarm and zone fault indication• option to equip a redundant main board processor (second CPU)• power supply 192 W and monitored battery condition• usable for two batteries 12 V / up to 65 Ah
technical specification
input voltage 230 V AC (-15 % / +10%)frequency 50 / 60 Hzoperation voltage 21,0 up to 29,2 V DCpower supply 192 Wemergency power max. 2 x 12 V / 45 Ahinterfaces 2x RS 232/422 Bitbus (option)display LCD 4 x 20 characterszone LED´s poss. for up to 192 zone indicatorssounder output 24 V DC / 400 mA monitoredexternal user output 2 x 24 V DC / 800 mA relay output 3 change over 250 V / 5 Aopen collector output 9 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Chumidity max. 95 %protection class IP 30front color tele grey, RAL 7046material sheet steelweight 20 kgdimensions (H x W x D) 6 HE x 19"approvals VdS: G 203067, S 295054, LPCB,
GOST, CCC, Hungary, Bulgaria,Lithuania, Czech Republik, Ukrain,Slovakia, Slovenia, Spain,Switzerland, Belgium
complies with EN 54 - 2
remarks:• the panel is designed to be mounted in a 19"- rack • the power pack is separately mounted in the 19"- rack• additional space is required for battery storage
www.detectomat.com
14
1.2 detect 3016 fire control panel and accessories
1. fire control panels
2-loop interface redundant DLI 3240 X2-R
to plug in to the detect 3016 fire control panel for max. 2 x 126loop3000 components
• maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm)• all loop3000 components can be addressed automatically• manual addressable with EasyCheck 3000 (31482) • two - wire - loop• 8 freely programmable open collector outputs• 3 open collector outputs 30 V DC / 90 mA for alarm and fault• oop voltage 32 V DC, loop current 100 mA per loop• RS 232 interface for additional data monitoring• redundant board processor unit to duplicate the functions
technical specification
operation voltage 20 up to 28 V DCquiesent current 40 mAalarm current max. 2 x 100 mA interfaces RS 232open collector output 11 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Cweight 200 gdimensions (H x W x D) 140 mm x 140 mm x 30 mm
remarks: use the current version of the loop calculator to determinthe maximum number of loop devices/components and mix
art. 30201
2-loop interface active, redundant DLI 3240 P X2-R
picture similar
to plug in to the detect 3016 fire control panel for max. 2 x 126loop3000 components
• maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm)• all loop3000 components can be addressed automatically• manual addressable with EasyCheck 3000 (31482) • two - wire - loop• 8 freely programmable open collector outputs• 3 open collector outputs 30 V DC / 90 mA for alarm and fault• loop voltage 32 V DC, loop current 140 mA per loop• RS 232 interface for additional data monitoring• redundant board processor unit to duplicate the functions
technical specification
operation voltage 20 up to 28 V DCquiesent current 40 mAalarm current max. 2 x 140 mA interfaces RS 232open collector output 11 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Cweight 200 gdimensions (H x W x D) 140 mm x 140 mm x 30 mmapprovals VdS: G 203067
remarks: use the current version of the loop calculator to determinthe maximum number of loop devices/components and mix
art. 32099
www.detectomat.com
15
1.2 detect 3016 fire control panel and accessories
1. fire control panels
conventional interface redundant 8 fire zones CP CLI X2-R
to plug in to the detect 3016 fire control panel for max. 8 conventionalfire zones
• maximum 25 conventional detectors per fire zone connectable• 8 freely programmable open collector outputs 30 V DC / 90 mA• 3 open collector outputs 30 V DC / 90 mA• redundant board processor unit to duplicate the functions
technical specification
operation voltage 20 up to 28 V DCquiesent current 60 mAalarm current 85 mA + 50 mA per zone outputopen collector output 11 open collector 30 V DC / 90 mAoperation temperature -5°C up to +40°Cweight 200 gdimensions (H x W x D) 140 mm x 140 mm x 30 mm
art. 30096
extension module CP ECB
to expand the detect 3016 fire control panel mother board
• 3 slots for plug in 2 additional loop-/conventional interfacesand 1 alarm module
technical specification
operation temperature -5°C up to +40°C
remarks: maximum up to 2 units per detect 3016 fire control panel usable
art. 30097
LED indicator modul CP ZM 32
two LED indicators for 32 zones per modul to plug into the fire controlpanel detect 3016 for zone alarm and zone fault indication
• 1 red and 1 yellow LED per fire zone• 32 fire zones on 1 modul
technical specification
alarm current 3 mA per zoneoperation temperature -5°C up to +40°Cdimensions (H x W) 108 mm x 193 mm
remarks: maximum of 6 LED indicator modules
art. 30098
www.detectomat.com
16
1.2 detect 3016 fire control panel and accessories
1. fire control panels
mounting panel MP-1
expansion mounting front to add 19" components for the 19" cabinate technical specification
material sheet steeldimensions (H x W) 878 mm x 485 mm
remarks: one mounting plate MP-1 is included in the deivery of the19" cabinet 30162 und 30163
art. 30164
19" front panel 64 19" FP-1
to integrate 2 zone alarm device indications type 30098
• front foil with label for fire zones 1-64
technical specification
front color tele grey, RAL 7046material sheet steeldimensions (H x W) 3HE x 19"
art. 30167
19" front panel 128 19" FP-2
to integrate 2 zone alarm device indications type 30098
• front foil with label for fire zone 65 - 128
technical specification
front color tele grey, RAL 7046material sheet steeldimensions (H x W) 3HE x 19"
art. 30168
19" front panel 192 19" FP-3
to integrate 2 zone alarm device indications type 30098
• front foil with label for fire zone 129 - 192
technical specification
front color tele grey, RAL 7046material sheet steeldimensions (H x W) 3HE x 19"
art. 30169
mounting plate CP MP 3016
expansion mounting plate to plug in to the detect 3016 fire controlpanel front for up to 6 LED indicator modules or / and protocol printerincluding front foil
• mounting plate for maximum 6 LED indicator modules • provides possibility for protocol printer 30099 or 30106• zones can be identified by labelling
technical specification
operation temperature -5°C up to +40°Cdimensions (H x W) 400 mm x 483 mm
remarks: laterly installation into the detect 3016 fire control panel possible
art. 31947
www.detectomat.com
17
1.2 detect 3016 fire control panel and accessories
1. fire control panels
extinguishing control modul CP ETB X2
plug in extinguishing control module for the detect 3016 fire panelto control one extinguishing area
• direct activation of the extinguishing area valves• 4 monitored control lines for signal transmitter and solenoid valves• activation from loop or conventional interface
technical specification
operation voltage 20 up to 28 V DCquiesent current 45 mAalarm current 60 mA + 1 A per outputsounder output 4 x 24 V DC / 1 A monitoredexternal user output 4 x 24 V DC / 1 A monitoredoperation temperature -5°C up to +40°Cdimensions (H x W x D) 140 mm x 140 mm x 20 mmapprovals VdS G 203 067
remarks: an additional extinguishing panel is not necessary
art. 40003
redundant main board processor CP CPU X2-R
to plug in to the detect 3016 fire panel to duplicate the main boardprocessor
• takes over the control in case of CPU-failure
technical specification
quiesent current 50 mAalarm current 50 mAoperation temperature -5°C up to +40°C
art. 30112
universal expansion housing UZG-2
provides additional space for ancilary components
• sheet steal housing compatible with fire control panel detect 3016
• lock for door
technical specification
protection class IP 30housing colour light grey, RAL 7035front color tele grey, RAL 7046material sheet steelweight 10 kgdimensions (H x W x D) 750 mm x 600 mm x 240 mm
art. 31320
www.detectomat.com
18
1.3 detect 3004/3016 panel accessories
1. fire control panels
relay board 8 change over RL 58
to expand 8 relay outputs for all fire control panels of the system detect 3000
• 8 potential-free output relays,change over contact
• 8 inputs controlled by the fire control panel
• 8 LED´s to display the current operation status
• mountabel on C-rails 35mm in the panel
technical specification
operation voltage 21 up to 28 V DCquiesent current 3,5 mAalarm current 25 mA per relayrelay output 8 x change over 250 V / 5 Aoperation temperature -5°C up to +40°Cprotection class IP 20housing color greenmaterial ABSdimensions (H x W x D) 125 mm x 110 mm x 60 mmapprovals VdS G 203 067
art. 30077
monitored module for 4 outputs SC 4
to expand 4 monitored outputs for all kind of signalling devices on the fire control panels of the system detect 3000
• external powered via fire control panel
• 4 jumpers "acoustics on/off option" to control the noise of the outputs
• 4 output channels with 24 V for all kind of signalling devices
• output current 400 - 600 mA choosable by jumper • monitorings for short circuit, broken wire, general fault and alarm• 4 alarm inputs to activate the selected output• 1 general alarm input to activate all outputs
• "Acoustics on / off" input to disable, set or reset all of the outputs selected by the jumpers
technical specification
operation voltage 21 up to 28 V DCquiesent current 1,6 up to 2,5 mA alarm current 2,5 mA + 400/600 mA per outputsounder output 4 x 24 V DC / 400 or 600 mA
monitoredoperation temperature -5°C up to +40°Cprotection class IP 20housing color greenmaterial ABSdimensions (H x W x D) 125 mm x 130 mm x 50 mm
art. 32066
monitored module for 8 outputs SC 8 VdS G 203067
to expand 8 monitored outputs for all kind of signalling devices onthe fire control panels of the system detect 3000
• 8 monitored 24 V DC / 400 mA for signalling devices (separate fused)
• 8 open collector outputs for LED indicators• 8 alarm inputs to activate the selected output
• 8 manual switched inputs • 1 general alarm input to activate all outputs• external powered 24 V DC / maximum 3,2 A
technical specification
operation voltage 21 up to 28 V DCquiesent current 58 mAalarm current 58 mA + 400 mA per outputsounder output 8 x 24 V DC / 400 mA monitoredopen collector output 12 outputs 24 V DC / 90 mAoperation temperature -5°C up to +40°Cprotection class IP 20housing color greenmaterial ABSdimensions (H x W x D) 125 mm x 175 mm x 60 mmapprovals VdS G 203 067
remarks: it is essential to use the interface 31446 in the fire control panel
art. 30118
www.detectomat.com
19
1.3 detect 3004/3016 panel accessories
1. fire control panels
OC control module CP AM 32art. 30115
connection board CP AM AP
connection board for a separate installation of the CP AM 32
• connectable via housing on DIN rails 35 mm• usable as connecting box for the OC control module in
installations outside the fire control panel
technical specification
protection class IP 20housing colour orangematerial ABSdimensions (H x W x D) 88 mm x 175 mm x 70 mm
art. 30116
extinguishing interface CP SIE
interface to expand the fire control panel detect 3000 for connectionon an extinguishing control panel
• connection of extinguishing control panels for several areas possible
• indication and control functions according VdS
technical specification
operation voltage 21 up to 28 V DCquiesent current 30 mArelay output 8 x change over 250 V / 5 Aoperation temperature -5°C up to +40°Cprotection class IP 20housing color greenmaterial ABSdimensions (H x W x D) 125 mm x 110 mm x 60 mmapprovals VdS G 203 067
remarks:• it is essential to use a conventional interface to connect the
detector zones in the fire control panel• maximum 4 extinguishing areas programmable
art. 30114
to expand 32 open collector outputs for all kind of control functionson the fire control panels of the system detect 3000
• 32 open collector outputs 24 V DC / 90 mA • all outputs are free programmable for alarm events in the fire
control panel• up to 6 boards usable in detect 3016• up to 24 outputs usable in detect 3004
technical specification
operation voltage 21 up to 28 V DCquiesent current 3,5 mAalarm current 25 mA per relayinterfaces RS 232open collector output 32 outputs 24 V DC / 90 mAoperation temperature -5°C up to +40°Cdimensions (H x W x D) 140 mm x 140 mm x 25 mmapprovals VdS G 203 067
www.detectomat.com
20
1.3 detect 3004/3016 panel accessories
1. fire control panels
parallel indicator display ZPA2002
parallel indicator display unit to display the current status of the firecontrol panels detect 3000
• including an additional interface RS232/422 and ESPA 4.4.4 for nurse call systems
• display with 4 x 20 characters
• simultaneous display of 2 messages• optional selection of RS 232 or RS 422• communication length max. 800 m • including buzzer• collectiv LED indicators for operation, alarm, fault and cut-off• powered via fire control panel• automatically data-transfer from the fire control panel• more than 4.000 texts programmable
technical specification
operation voltage 10 up to 30 V DCquiesent current 35 mAalarm current 100 mAinterfaces RS232/422 ESPA 4.4.4operation temperature -5°C up to +40°Cprotection class IP 30housing color light grey, RAL 7035front colour blackmaterial ABSdimensions (H x W x D) 273 mm x 223 mm x 54 mmapprovals VdS G 203086
art. 31596
mount in printer PIP 2
to expand the front of the fire control panel detect 3000 with a printer
• thermo printer with 24 characters• 58 mm paper width• integrated printer memory of 8 k RAM• direct connectable on the fire
control panels interface RS 232• powered via fire control panel
remarks: by using the printer in the fire control panel detect 3004are maximum 18 Ah batteries usable, it is essential to specify an CPMP for the panel when ordering
technical specification
operation voltage 21 up to 28 V DCquiesent current 12 mAalarm current 100 mAinterfaces RS 232operation temperature -5°C up to +40°Cprotection class IP 30front colour blackmaterial ABSdimensions (H x W x D) 115 mm x 115 mm x 80 mmapprovals VdS G 203 067
art. 30106
mount in printer including paper storage PIP 1
to expand the front of the 19" fire control panel detect 3000 with a printer
• thermo printer with 24 characters• 58 mm paper width• integrated printer memory of 8 k RAM• direct connectable on the fire control
panels interface RS 232• powered via fire control panel
remarks: only usable for 19" housings, it is essential to specify a CPMP for the panel when ordering
technical specification
operation voltage 21 up to 28 V DCquiesent current 40 mAalarm current 460 mAinterfaces RS 232operation temperature -5°C up to +40°Cprotection class IP 30front colour silvermaterial aluminiumdimensions (H x W x D) 130 mm x 107 mm x 165 mmapprovals VdS G 203 067
art. 30099
www.detectomat.com
21
1.3 detect 3004/3016 panel accessories
1. fire control panels
power supply 120 W NT 5
usable as additional power supply for the detect 3000 system
• power supply 230 V AC, 24 V DC, 5 A• temperature compensated battery-loading• integrated LED indicators for operation and fault
technical specification
input voltage 230 V ACfrequency 50 / 60 Hzoperation voltage 24 V DCpower supply 120 Wexternal user output 3 x 1,6 A separately fusedoperation temperature -5°C bis +40°Cprotection class IP 30housing color light grey, RAL 7035front colour tele grey, RAL 7046material sheet steelweight 13,0 kgdimensions (H x W x D) 442 mm x 525 mm x 200 mm
art. 30471
power supply 192 W NT 8
usable as additional power supply for the detect 3000 system
• power supply 230 V AC, 24 V DC, 8 A• temperature compensated battery-loading• integrated LED indicators for operation and fault
technical specification
input voltage 230 V ACfrequency 50 / 60 Hzoperation voltage 24 V DCpower supply 155 Wexternal user output 4 x 1,6 A separately fusedoperation temperature -5°C bis +40°Cprotection class IP 30housing color light grey, RAL 7035front colour tele grey, RAL 7046material sheet steelweight 16,0 kgdimensions (H x W x D) 442 mm x 525 mm x 200 mm
art. 30131
battery 12 V / 7,2 Ah B 12/ 7,2Ah
• plug-in connections: 4,8 mm
technical specification
weight 2600 gdimensions (H x W x D) 99 mm x 150 mm x 65 mmapprovals VdS G 103061
art. 40056
battery 12 V / 12 Ah B 12/ 12Ah
• plug-in connections: 6,3 mm technical specification
weight 4200 gdimensions (H x W x D) 98 mm x 151 mm x 98 mmapprovals VdS G 103063
art. 30155
www.detectomat.com
22
1.3 detect 3004/3016 panel accessories
1. fire control panels
base for overvoltage protection modules CT B
for connection of one protection module
• overvoltage protection max. permanent voltage 250 V AC or 350 V DC• for two wires
technical specification
operation voltage 250 V AC / 350 V ACoperation temperature -40°C up to +80°Cprotection class IP 20housing color yellowmaterial PA 6.6dimensions (H x W x D) 90 mm x 12 mm x 44 mm
art. 30321
battery 12 V / 26 Ah B 12/ 26Ah
• screw connections for M 5 technical specification
weight 8,5 kgdimensions (H x W x D) 125 mm x 176 mm x 166 mmapprovals VdS G 103065
art. 40001
battery 12 V / 45 Ah B 12/ 45Ah
• screw connections for M 6 technical specification
weight 14,5 kgdimensions (H x W x D) 170 mm x 197 mm x 165 mmapprovals VdS G 102002
art. 30151
battery 12 V / 65 Ah B 12/ 65Ah
• screw connections for M 6 technical specification
weight 30,0 kgdimensions (H x W x D) 174 mm x 350 mm x 174 mmapprovals VdS G 102001
art. 30461
battery 12 V / 18 Ah B 12/ 18Ah
• screw connections for M 5 technical specification
weight 6,5 kgdimensions (H x W x D) 167 mm x 81 mm x 76 mmapprovals VdS G 103064
art. 30156
www.detectomat.com
23
1.3 detect 3004/3016 panel accessories
1. fire control panels
loop protection module CT ME 48
overvoltage protection for all loop3000 panel boards and open collector outputs
• overvoltage protection for loop3000• nominal discharge current (8/20 µs): 10 kA
art. 30335
conventional protection module CT ME / C 24
overvoltage protection for conventional zones
• overvoltage protection for conventional zones• nominal discharge current (8/20 µs): 10 kA
art. 30336
bitbus protection module CT ME 5
overvoltage protection for BitBus data cables
• overvoltage protection for conventional zones• nominal discharge current (8/20 µs): 10 kA
art. 30337
modem RM MO
interface modem to control the fire control panels detect 3000via phone line
• interface to connect the control panels detect 3000 via phone line• connectable via RS232 on the panel• powered via the rife control panel
technical specification
input voltage 230 V ACfrequency 50 / 60 Hzoperation voltage 9 up to 30 V AC or 9 up to 42 V DCinterfaces RS 232housing color greyfront colour greymaterial aluminiumdimensions (H x W x D) 35 mm x 110 mm x 130 mm
art. 30138
www.detectomat.com
24
1.4 network components
1. fire control panels
remote display- and control panel ABF
to expand the detect 3000 fire detection network for an separateremote display- and control panel, wall mount housing
• display- and control panel DIN EN 54 part 2• including Bitbus interface for interlink connection• 4 alphanumeric lines LCD- display with backlight • 2 slots for fire brigade and network interface • 128 programmable detector zones• possibility for integration of fire brigade interface, display panel,
transmission- and key-depot adapter interface • 3 potential-free relay outputs (250 V / 5 A)• 9 open collector outputs (30 V / 90 mA)• monitored signal transmitter 400 mA• 2 RS 232 interfaces for personal computer, printer, modem,
building management system• network compatible via bitbus interface up to 32 fire control
panels or additional 63 bitbus components
• operation and event memory for 500 messages (first in first out principle)
• option to equip a redundant main board processor (second CPU)• external powered via fire control panel or power supply• wall mount housing
technical specification
operation voltage 21,0 up to 29,2 V DCpower supply 72 Wemergency power max 2 x 12 V / 12 Ahquiesent current 132 mAalarm current 192 mAinterfaces 2 x RS 232/422 Bitbus (option)display LCD 4 x 20 characterssounder output 24 V DC / 400 mA monitoredexternal user output 24V DC / 800 mArelay output 3 change over 250 V / 5 Aopen collector output 9 open collector 30 V DC / 90 mAoperation temperature -5°C bis +40°Chumidity up to 95 %protection class IP 30 housing color light grey, RAL 7035front color tele grey, RAL 7046material sheet steelweight 6 kgdimensions (H x W x D) 262 mm x 420 mm x 83 mmcomplies with EN 54 - 2
remarks:• it is essential to have a separate master display- and control
panel ABF in the BitBus network• to create an display and control panel including power supply
you have to use an detect 3004 shallow with and language kit ABF• it is essential to specify an language kit when ordering
art. 32118
language kit German for a master panel in the BitBus network LK ABF D
language kit integrates German software, German description,German labelling
remarks: it is essential to specify the language kit when ordering
art. 32039
language kit English for a master panel in the BitBus network LK ABF GB
language kit integrates English software, English description,English labelling
• additional languages available on request
remarks: it is essential to specify the language kit when ordering
art. 32040
www.detectomat.com
25
1.4 network components
1. fire control panels
remote display- and control panel ABF-19”
to expand the detect 3000 fire detection network for an separateremote display- and control panel, 19" or mount in version
• display- and control panel DIN EN 54 part 2• including Bitbus interface for interlink connection• 4 alphanumeric lines LCD- display with backlight • 2 slots for fire brigade and network interface • 128 programmable detector zones• possibility for integration of fire brigade interface, display panel,
transmission- and key-depot adapter interface • 3 potential-free relay outputs (250 V / 5 A)• 9 open collector outputs (30 V / 90 mA)• monitored signal transmitter 400 mA• 2 RS 232 interfaces for personal computer, printer, modem,
building management system• network compatible via bitbus interface up to 32 fire panel
controls or additional 63 bitbus components• operation and event memory for 500 messages
(first in first out principle)• option to equip a redundant main board processor (second CPU)
• external powered via fire control panel or power supply• 19" or mount in front
technical specification
operation voltage 21,0 up to 29,2 V DCpower supply 72 Wemergency power max 2 x 12 V / 12 Ahquiesent current 132 mAalarm current 192 mAinterfaces 2x RS 232/422 Bitbus (option)display LCD 4 x 20 characterssounder output 24 V DC / 400 mA monitoredexternal user output 24 V DC / 800 mArelay output 3 change over 250 V / 5 Aopen collector output 9 open collector 30 V DC / 90 mAoperation temperature -5°C bis +40°Chumidity up to 95 %protection class IP 30 housing color light grey, RAL 7035front color tele grey, RAL 7046material sheet steelweight 6 kgdimensions (H x W x D) 6 HE x 19” x 83 mmcomplies with EN 54 - 2
remarks:• it is essential to have a separate master display- and control
panel ABF in the BitBus network• to create an display and control panel including power supply
you have to use an detect 3004 shallow with and language kit ABF• it is essential to specify an language kit when ordering
art. 32119
LCD repeater panel LCD-Tableau
remote display unit for communication with the fire detection system detect 3000
• displaying of the current status of all loop devices and zones in the BitBus network
• monitored interface to the BitBus network
• maximum 61 repeater panels in one BitBus network usable
• 4 lines with backlight LC-display• display character size 10 mm• integrated buzzer, with quiesent button• scroll-function of the display by buttons• flat design housing made of brushed stainless steel• automatic data-transfer from the fire control panel• external voltage supply 24 V DC
technical specification
operation voltage 21 up to 28 V DCinterfaces Bitbusdisplay LCD 4 x 20 charactersoperation temperature -5°C bis +40°Chumidity up to 95 %protection class IP 30 housing color silverfront color greymaterial stainless steeldimensions (H x W x D) 240 mm x 295 mm x 43 mm
art. 31315
bitbus CPU BB-CPU
seperate intellegent unit to control outputs in the BitBus network without using fire control panels
• up to 8 extensions 30120 / 30122 connectable• housing for plug in on DIN rails
• maximum 61 units in one BitBus network usable• outputs free programmable• external powered 24 V DC
technical specification
operation voltage 21 up to 28 V DCquiesent current 150 mAalarm current 150 mAinterfaces Bitbusoperation temperature -5°C bis +40°Cprotection class IP 20 housing color greenmaterial ABSdimensions (H x W x D) 125mm x 133 mm x 58 mm
remarks: it ist essential to programm the unit via bitbus modem30139 together with the DPT3000 software
art. 30119
www.detectomat.com
26
1.4 network components
1. fire control panels
extension for BitBus CPU, 32 open collector outputs BB-32
to expand the BitBus CPU for 32 open collector outputs
• 32 open collector outputs 24 V DC / 90 mA
• housing for plug in on DIN rails• up to 8 units on one BitBus CPU usable
technical specification
operation voltage 21 up to 28 V DCquiesent current 5 mAalarm current max. 320 mAopen collector output 32 open collector 30 V DC / 90 mAoperation temperature -5°C bis +40°Cprotection class IP 20 housing color greenmaterial ABSdimensions (H x W x D) 125 mm x 163 mm x 60 mm
art. 30120
bitbus interface CP BBI
to expand the fire control panel detect 3000 to interlink several fire control panels, control- and display panels and other bitbus components
• to build up a fire control panel network of up to 32 fire control panels and up to 64 BitBus components
• via 4-wired interface distances up to 1.200 m (3,900 feet) possible• via bitbus repeater a max. of 13.200 m can be realized in
one network• data rate max 375 kBd
technical specification
operation voltage 21 up to 28 V DCinterfaces Bitbusoperation temperature -5°C bis +40°Cdimensions (H x W x D) 25 mm x 50 mm x 59 mm
art. 30087
www.detectomat.com
27
1.4 network components
1. fire control panels
BitBus amplifier BB-R
booster for refreshing the BitBus-signals for cable length > 1200 m
• each repeater increase the length of the BitBus network up to 1.200 m
• 10 repeater units in one network usable (13.200 m)• the repeater needs no address in the BitBus network
• including power supply
technical specification
input voltage 230 V ACfrequency 50 / 60 Hzoperation voltage 5 V DCinterfaces 2 x Bitbusemergency power optionalinterfaces 2 x Bitbusprotection class IP 52operation temperature -5°C bis +40°Cprotection class IP 20 housing color greymaterial ABSdimensions (H x W x D) 122 mm x 66 mm x 54 mm
art. 30124
BitBus LED indicator extension BB-LED
seperate intellegent unit to control LED indicators in the BitBus networkwithout using fire control panels
• for max. 192 LED indicators per interface• 6 connection interfaces for LED indicator modul CP ZM 32• maximum 61 units in one BitBus network usable
• outputs free programmable• external powered 24 V DC
technical specification
operation voltage 21 up to 28 V DCquiesent current 155 mAalarm current max. 320 mAinterfaces Bitbusexternal user output 6 x cable connection for CP ZM 32operation temperature -5°C bis +40°Cprotection class IP 20 housing color greenmaterial ABSdimensions (H x W x D) 125 mm x 275 mm x 75 mm
art. 30128
extension for BitBus CPU, 16 relay outputs BB-16
to expand the BitBus CPU for 16 relay outputs
• 16 relay outputs 30 V DC / 2 A• housing for plug in on DIN rails• upto 8 units on one BitBus CPU usable
technical specification
operation voltage 21 up to 28 V DCquiesent current 5 mAalarm current max. 320 mArelay output 3 change over 30 V / 2 Aoperation temperature -5°C bis +40°Cprotection class IP 20 housing color greenmaterial ABSdimensions (H x W x D) 125 mm x 163 mm x 60 mm
art. 30122
www.detectomat.com
28
1.4 network components
1. fire control panels
BitBus - fibre optical interface LCON-1
active interface modul to realize an fibre optical BitBus network forthe fire control panels detect 3000
• converter with one fibre optical and one bitbus channel• fibre optical connector F-ST
• transmission rate max. 5 Mbit each second• maximum transmission distance per unit 2.600 m• wave length 820 mm• transmission half duplex• externally powered
technical specification
operation voltage 18 up to 30 V DCquiesent current 250 mAinterfaces Bitbus F-SToperation temperature 0°C up to +70°Cprotection class IP 30housing color blackmaterial polyamid weight 250 gdimensions (H x W x D) 82 mm x 93 mm x 22,5 mm
art. 31621
fibre optical cable converter LCON-2art. 31622
BitBus computer interface ISA-Slot BBI PC
to connect the computer to the fire control panel detect 3000network
• interface for connection of the visual detect software to the BitBus network
• ISA slot plug-in card with integrated BitBus interface• maximum two usable in one BitBus network
technical specification
operation voltage 5 V DCinterfaces ISA-Bitbusoperation temperature -5°C up to +40°C
remarks: up to 99 computers can be connected in the detect 3000 systemvia user extensions in the visual detect software via TCP/IP protocol
art. 31024
to active couple the bitbus to the fibre optical cable redundant transmission path
• LCON is a bitbus fibre optical cable converter with two fibre optical cable channels and one bitbus channel
• fibre optical cable connector F-ST
• transmission rate max. 5 Mbit each second• optical budget 8 (4,2) dB• transmission path 2.600 (1.400) m• wave length 820 mm• transmission half duplex
technical specification
operation voltage 18 up to 30 V DCquiesent current 250 mAinterfaces Bitbus F-SToperation temperature 0°C up to +70°Cprotection class IP 30housing color blackmaterial polyamid weight 250 gdimensions (H x W x D) 82 mm x 93 mm x 40 mm
www.detectomat.com
29
1.5 programming tools and software
1. fire control panels
I-Check 3000 software I-Check 3000
loop configuration and test software
• loop diagnostics and the location of failures are automatically displayed in a graphic of the loop3000 devices
• graphical representation of the loop structure via software • the loop devices are constantly analysed and the analogue values
are displayed • graphical display of the analogue values of smoke, contamination,
temperature, loop-voltage and temperature-compensation • display of detector-type, serial-number, detector-zone with number,
free customer text • all data can be exported in Excel or Word files• extensive print functions of graphics and charts• configuration for all loop devices (algorithms, sensitivities, etc.) • Windows based user interface• the software runs on required Windows 98, 2000 or XP • supports by loop Tester LT 3000• data medium CD-ROM
art. 30501
detectomat programming tool DPT 3000
configuration software for the fire control panels, the separate remote display- and repeater panel and the BitBus CPU of thesystem detect 3000
• programming of the fire control panel• network-configuration• supported by remote maintenance
(software-expansion-dongle 30137)• Windows user interface• the software runs on required Windows 98, 2000 or XP • Data medium CD-ROM
art. 30136
software-expansion-dongle D 3000
software protection dongle for remote acces for all fire contraolpanels of the system detect 3000
• protection for the software• activation of the features: remote diagnostics, status display
and remote control of the fire control panel detect 3004, 3016and the separate display repeater via the fire control modem
• dongle for 25 pole printer interface
art. 30137
Bitbus programming tool BPT
programming tool for the BitBus CPU • including power supply connection and interface cables
art. 30139
www.detectomat.de
30
1.5 programming tools and software
1. fire control panels
EasyCheck EC 3000
manual programming tool for all loop3000 devices
• manual addressing and programming tool for all loop3000devices
• battery-operated stand-alone unit• double-spaced lighted LC-display• keypad • Integrated detector base• separate connection for loop modules and manual call points • read-out and changing of the addresses and grades of sensitivity
of all loop3000 elements• copy-function for device replacement• transportation suitcase, 3 batteries type AA, interface-cable,
carrier-belt, cable to connect modules and manual call points areincluded in the delivery
art. 31482
loop tester LT 3000
loop testing tool for the all loop3000 installations, usable withoutpanel installation
• test and programming tool for one loop• direct connection to the personal computer• independent operation without fire control panel • loop diagnostics and the location of failures are automatically
displayed in a graphic of the loop3000 devices • graphical representation of the loop structure via software • the loop devices are constantly analysed and the analogue
values are displayed • graphical display of the analogue values of smoke,
contamination, temperature, loop-voltage and temperature-compensation
• display of detector-type, serial-number, detector-zone with number, free customer text
• all datas can be exported in Excel or Word files• extensive print-functions of graphics and charts• configuration for all loop devices (algorithms, sensitivities, etc.) • Windows based user interface• the software runs on Windows 98, 2000 or XP
art. 31625
www.detectomat.de
31
1. fire control panels1.6 visualization
visual detect basic software VD Basic 11
basic visualization software kit - basis software for one fire controlpanel and one work-station
• runs under Windows 2000/XP• network compatible (server-client principle)• modular structure of the software• full graphic visualization• simulation tool (to test the detectors and the programmed
system connections) • comprehensive operator and rights management, different
user-hierarchies can be created
• free definable alarm management, procedure-plans• option for automatic execution of procedure-plans• German/English/Russian bilingual• print function (e.g. print of fire brigade routing card, unit
location plans) • system consists of a development and a runtime interface • help function for development and runtime interface • bitbus-connection via internal ISA-bitbus card • password can be modified in the log-on window• data-codification between server and clients • detector data can be generated and read-in via the import-tool
from the dpt-program• authorization for one work-station and one fire control panel• stand-alone system possible, as data-transmission between
server and client via TCP/IP protocol• free creation of announcements• route-plans readable in all common CAD formats• screenshots und route-cards can be printed manual or automatic • all simulated messages and their execution are recorded and
can be analysed and retrieved with a filter • own projects are programmable, incl. scanning of unit location
plans, routing cards, places of addressed detectors and creation of procedure-briefings
• different user hierarchies can be created within the software by assigning individual rights
art. 30143
demo software for visual detect VD DV
demonstration kit for visualization software for fire control panelsdetect 3000 without active connection to a bitbus network
• runs under Windows 2000/XP• network compatible (server-client principle)• modular structure of the software• full graphic visualization• simulation tool (to test the detectors and the programmed
system connections)
• comprehensive operator and rights management, different user hierarchies can be created
• free definable alarm management, procedure-plans• option for automatic execution of procedure-plans• German/English/Russian bilingual• print function (e.g. print of fire brigade routing card, unit
location plans) • system consists of a development and a runtime interface • help function for development and runtime interface • bitbus-connection via internal ISA-bitbus card • password can be modified in the log-on window• data-codification between server and clients • detector data can be generated and read-in via the import-tool
from the dpt-program• full functionality within the system in one host without an active
connection to a bitbus network• procedure-plan are freely defined• location plans, screenshots and routing cards can be printed
manual and automatically • all simulated messages and their execution are recorded and
can be analysed and retrieved with a filter • own projects are programmable, incl. scanning of unit location
plans, routing cards, places of addressed detectors and creation of procedure-briefings
• different user hierarchies can be created within the software by assigning individual rights
art. 31911
www.detectomat.de
1.6 visualization
1. fire control panels
1.7 conventional panels
conventional fire control panel BMZ 6
conventional fire control panel with 6 detector-zones
• 6 quiescent current monitored detector zones • maximum 30 automatic detector each zone • 6 relay outputs for alarm and fault • 2 monitored outputs for signalling devices 300 mA • space for battery 1 x 12 V / 7 Ah
technical specification
input voltage 230 V ACfrequency 50 / 60 Hzoperation voltage 24 V DCemergency power 1 x 12 V / 7,5 Ahquiesent current 190 mAdisplay LED indicationszone LED´s for 6 zonessounder output 2x 24V 300mA monitoredrelay output 1 relay per zoneoperation temperature -5°C up to +40°Chousing color greymaterial ABSweight 2 kgdimensions (H x W x D) 240 mm x 325 mm x 80 mm
art. 30941
32
Visual detect user expansion VD UE 1
one workstation expansion kit - for the expansion of one workstation / user in the TCP/IP network
• multiple workstations-expandable by one• possibility to work in the network• messages notification and "send messages" • operator specific classificated messages and rights possible
art. 30144
Visual detect operation expansion VD CE 1
license kit - for the remote control function expansion via visualization software
art. 30146
Visual detect interface management system VD M I
license kit - interface to building management systems (BMS) for data support
art. 31654
Visual detect expansion panel VD PE 1
one fire control panel expansion kit - for one fire control panel in the BitBus network
• expandable by one fire control panel unit each• a maximum of 20 units can be managed• operator specific classificated messages and rights possible
art. 30145
www.detectomat.com
33
2.1 loop3000 - adressable detectors
2. detectors
optical smoke detector PL 3200 O
intelligent detector for loop3000, 2 optical sensors, complies with EN 54 part 7 specification
• loop3000 is a high functional detection-system• superior operational reliability from intelligent analysis of the
measuring chamber signal • a second independent optical measuring channel • a dedicated thermal-sensor provides a display of the detector
temperature profile at the fire control panel• real sensor-tests are carried out on a periodical basis • detector-sensitivity is freely programmable
• different sensitivities are programmable for day and night periods
• a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • automatic fault monitoring of the measuring chamber electronics• self learning mode in respect of environmental conditions • recognition of the exact contamination-status• automatic adjustment of the alarm sensitivity in case of
contamination • multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAopen collector output 10 mA for LED indicatorssensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cprotection class IP 40housing color whitematerial ABSdimensions (H x Ø) 44 mm x 100 mmapprovals VdS G 202003complies with EN 54 - 7
art. 30009
optical smoke detector, isolator PL 3300 O
intelligent detector for loop3000, 2 optical sensors and bidirectionalisolator, complies with EN 54 part 7 specification
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch• superior operational reliability from intelligent analysis of the
measuring chamber signal • a second independent optical measuring channel • a dedicated thermal-sensor provides a display of the detector
temperature profile at the fire control panel• real sensor-tests are carried out on a periodical basis • detector-sensitivity is freely programmable• different sensitivities are programmable for day and
night periods • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • automatic fault monitoring of the measuring chamber electronics• self learning mode in respect of environmental conditions • recognition of the exact contamination-status
• automatic adjustment of the alarm sensitivity in case of contamination
• multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAopen collector output 10 mA for LED indicatorssensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cprotection class IP 40housing color whitematerial ABSdimensions (H x Ø) 44 mm x 100 mmapprovals VdS G 202002complies with EN 54 - 7
art. 30011
optical smoke detector, isolator, white PL 3304 O white
intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification,design 4, color white
• features as PL 3300 O
technical specification
dimensions (H x Ø) 47 mm x 110 mmapprovals VdS G 204088complies with EN 54 - 7
art. 30555
optical smoke detector, isolator, black PL 3301 O black
intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification,design 1, color black
• features as PL 3300 O
technical specification
dimensions (H x Ø) 42 mm x 95 mmapprovals VdS G 205046complies with EN 54 - 7
art. 30525
optical smoke detector, isolator, silver PL 3301 O silver
intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification,design 1, color silver
• features as PL 3300 O
technical specification
dimensions (H x Ø) 42 mm x 95 mmapprovals VdS G 205046complies with EN 54 - 7
art. 30488
www.detectomat.com
34
2.1 loop3000 - adressable detectors
2. detectors
optical smoke detector, isolator, white PL 3301 O white
intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification,design 1, color white
• features as PL 3300 O
technical specification
dimensions (H x Ø) 42 mm x 95 mmapprovals VdS G 205046complies with EN 54 - 7
art. 30956
www.detectomat.com
35
2.1 loop3000 - adressable detectors
2. detectors
optical smoke detector, isolator, silver PL 3305 O silver
intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification,design 5, color silver
• features as PL 3300 O
technical specification
dimensions (H x Ø) 47 mm x 110 mmapprovals VdS G 204089complies with EN 54 - 7
art. 30568
optical smoke detector, isolator, silver PL 3304 O silver
intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification,design 4, color silver
• features as PL 3300 O
technical specification
dimensions (H x Ø) 47 mm x 110 mmapprovals VdS G 204088complies with EN 54 - 7
art. 30556
optical smoke detector, isolator, white PL 3305 O white
intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification,design 5, color white
• features as PL 3300 O
technical specification
dimensions (H x Ø) 47 mm x 110 mmapprovals VdS G 204089complies with EN 54 - 7
art. 30567
optical smoke detector, isolator PL 3300 O/K
intelligent detector for loop3000, specifically for the detection in airstreams and in aspirating smoke systems (<20 m/sec.),2 optical sensors and bidirectional isolator,complies with EN 54 part 7 specification
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch• superior operational reliability from intelligent analysis of
the measuring chamber signal • a second independent optical measuring channel • a dedicated thermal-sensor provides a display of the detector
temperature profile at the fire control panel• real sensor-tests are carried out on a periodical basis • detector-sensitivity is freely programmable• different sensitivities are programmable for day and
night periods • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • automatic fault monitoring of the measuring chamber electronics
• self learning mode in respect of environmental conditions • recognition of the exact contamination-status• automatic adjustment of the alarm sensitivity in case of
contamination • multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAopen collector output 10 mA for LED indicatorssensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cair speed up to 20m/secprotection class IP 40housing color whitematerial ABSdimensions (H x Ø) 44 mm x 100 mmapprovals VdS G 202 107complies with EN 54 - 7
art. 30092
www.detectomat.com
36
2.1 loop3000 - adressable detectors
2. detectors
optical smoke detector PL 3200 O/K
intelligent detector for loop3000, specifically for the detection in airstreams and in aspirating smoke systems (<20 m/sec.),2 optical sensors, complies with EN 54 part 7 specification
• loop3000 is a high functional detection-system• superior operational reliability from intelligent analysis of
the measuring chamber signal • a second independent optical measuring channel • a dedicated thermal-sensor provides a display of the detector
temperature profile at the fire control panel• real sensor-tests are carried out on a periodical basis • detector-sensitivity is freely programmable
• different sensitivities are programmable for day and night periods
• a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • automatic fault monitoring of the measuring chamber electronics• self learning mode in respect of environmental conditions • recognition of the exact contamination-status• automatic adjustment of the alarm sensitivity in case of
contamination • multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAopen collector output 10 mA for LED indicatorssensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cair speed up to 20m/secprotection class IP 40housing color whitematerial ABSdimensions (H x Ø) 44 mm x 100 mmapprovals VdS G 206 035complies with EN 54 - 7
art. 32045
www.detectomat.com
37
2.1 loop3000 - adressable detectors
2. detectors
heat detector PL 3200 T
intelligent detector for loop3000, 2 thermal sensors,complies with EN 54 part 5 specification
• loop3000 is a high functional detection-system• superior operational reliability from intelligent analysis of
the thermo sensor • temperature measurement via high sensitiv sensor• maximum and rate of rise analysis with thermal sensor technology• a dedicated thermal-sensor provides a display of the detector
temperature profile at the fire control panel• real sensor-tests are carried out on a periodical basis • detector-sensitivity is freely programmable
• different sensitivities are programmable for day and night periods
• a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • automatic fault monitoring of the measuring chamber electronics• self learning mode in respect of environmental conditions • recognition of the exact contamination-status• automatic adjustment of the alarm sensitivity in case of
contamination • multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAopen collector output 10 mA for LED indicatorssensitivity 60°C or rate of riseoperation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cair speed up to 20m/secprotection class IP 43housing color whitematerial ABSdimensions (H x Ø) 52 mm x 100 mmapprovals VdS G 203038complies with EN 54 - 5
art. 30008
heat detector, isolator PL 3300 T
intelligent detector for loop3000, 2 thermal sensors,complies with EN 54 part 5 specification
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch• superior operational reliability from intelligent analysis of
the thermo sensor • temperature measurement via high sensitiv sensor• maximum and rate of rise analysis with thermal sensor
technology• a dedicated thermal-sensor provides a display of the detector
temperature profile at the fire control panel• real sensor-tests are carried out on a periodical basis • detector-sensitivity is freely programmable• different sensitivities are programmable for day and
night periods • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • automatic fault monitoring of the measuring chamber electronics
• self learning mode in respect of environmental conditions • recognition of the exact contamination-status• automatic adjustment of the alarm sensitivity in case of
contamination • multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAopen collector output 10 mA for LED indicatorssensitivity 60°C or rate of riseoperation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cair speed up to 20m/secprotection class IP 43housing color whitematerial ABSdimensions (H x Ø) 52 mm x 100 mmapprovals VdS G 203037complies with EN 54 - 5
art. 30010
www.detectomat.com
38
2.1 loop3000 - adressable detectors
2. detectors
optical smoke and heat detector PL 3200 OT
intelligent detector for loop3000, 2 optical and 2 thermal sensors,complies with EN 54 part 5 and 7 specification
• loop3000 is a high functional detection-system• superior operational reliability from intelligent analysis of
the thermo sensor and the optical measuring chamber signal • temperature measurement via high sensitiv sensor• maximum and rate of rise analysis with thermal sensor technology• a second independent optical measuring channel • a dedicated thermal-sensor provides a display of the detector
temperature profile at the fire control panel• real sensor-tests are carried out on a periodical basis • detector-sensitivity is freely programmable
• different sensitivities are programmable for day and night periods
• a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • automatic fault monitoring of the measuring chamber electronics• self learning mode in respect of environmental conditions • recognition of the exact contamination-status• automatic adjustment of the alarm sensitivity in case of
contamination • multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAopen collector output 10 mA for LED indicatorssensitivity < 0,15 dB / m 60°C or rate of riseoperation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cair speed up to 20m/secprotection class IP 40housing color whitematerial ABSdimensions (H x Ø) 52 mm x 100 mmapprovals VdS G 205052complies with 54 - 7, 54 - 5
art. 30007
optical smoke and heat detector, isolator PL 3300 OT
intelligent detector for loop3000, 2 optical and 2 thermal sensors andbidirectional isolator, complieswith EN 54 part 5 and 7 specification
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch• superior operational reliability from intelligent analysis of
the thermo sensor and the optical measuring chamber signal • temperature measurement via high sensitiv sensor• maximum and rate of rise analysis with thermal sensor technology• a second independent optical measuring channel • a dedicated thermal-sensor provides a display of the detector
temperature profile at the fire control panel• real sensor-tests are carried out on a periodical basis • detector-sensitivity is freely programmable• different sensitivities are programmable for day and
night periods • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • automatic fault monitoring of the measuring chamber electronics
• self learning mode in respect of environmental conditions • recognition of the exact contamination-status• automatic adjustment of the alarm sensitivity in case of
contamination • multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAopen collector output 10 mA for LED indicatorssensitivity < 0,15 dB / m 60°C or rate of riseoperation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cair speed up to 20m/secprotection class IP 40housing color whitematerial ABSdimensions (H x Ø) 52 mm x 100 mmapprovals VdS G 205051complies with 54 - 7, 54 - 5
art. 30021
www.detectomat.com
39
2.1 loop3000 - adressable detectors
2. detectors
2.2 CT 3000 - conventional detectors
CO gas and heat detector, isolator PL 3300 CDBT
intelligent detector for loop3000, with carbon monoxid gas and 2 thermal sensors and bidirectional isolator, complies with EN 54part 5 specification
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch• superior operational reliability from intelligent analysis of
the thermo sensor and the carbon monoxid sensor signal • temperature measurement via high sensitiv sensor• maximum and rate of rise analysis with thermal sensor technology• carbon monoxid measurement via industrial detection sensor• pre alarm and alarm level for carbon monoxid • a dedicated thermal-sensor provides a display of the detector
temperature profile at the fire control panel• real sensor-tests are carried out on a periodical basis • detector-sensitivity is freely programmable
• different sensitivities are programmable for day and night periods • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • automatic fault monitoring of the measuring chamber electronics• self learning mode in respect of environmental conditions • recognition of the exact contamination-status• automatic adjustment of the alarm sensitivity in case
of contamination • multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 600 µAalarm current 5 mAnoise integreated buzzer for gas alarm
and pre alarm open collector output 10 mA for LED indicatorssensitivity 60°C or rate of rise
pre alarm 30 ppm COalarm 60 ppm CO
operation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cair speed up to 20m/secprotection class IP 43housing color whitematerial ABSdimensions (H x Ø) 58 mm x 100 mmcomplies with 54 - 7, 54 - 5
art. 30079
optical smoke detector CT 3000 O
conventional optical smoke detector,complies with EN 54 part 7 specification
• high functional detection-system • intelligent analysis of the measuring chamber signal
technical specification
operation voltage 9 up to 33 V Dcquiesent current 100 µAalarm current 20 mAopen collector output 15 mA for LED indicatorssensitivity < 0,15 dB / moperation temperature -10°C bis +60°Chumidity max. 95 % RH / 40°Cprotection class IP 43housing color whitematerial ABSdimensions (H x Ø) 44 mm x 100 mmapprovals VdS G 203036complies with 54 - 7
art. 30015
www.detectomat.com
40
2.2 CT 3000 - conventional detectors
2. detectors
optical smoke detector CT 3000 O/K
conventional detector, especially fot the detection in air streams and aspirating smoke systems (<20 m/sec.), with 2 optical sensors,complies with EN 54 part 7 specification
• high functional detection-system • intelligent analysis of the measuring chamber signal
technical specification
operation voltage 9 up to 33 V Dcquiesent current 100 µAalarm current 20 mAopen collector output 15 mA for LED indicatorssensitivity < 0,15 dB / moperation temperature -10°C bis +60°Chumidity max. 95 % RH / 40°Cprotection class IP 43housing color whitematerial ABSdimensions (H x Ø) 44 mm x 100 mmapprovals VdS G 203035complies with 54 - 7
art. 30977
optical smoke detector, silver CT 3001 O silver
conventional detector, complies with EN 54 part 7 specification,design 1
• features as CT 3000 O
technical specification
dimensions (H x Ø) 42 mm x 95 mm
art. 31589
optical smoke detector, white CT 3001 O white
conventional detector, complies with EN 54 part 7 specification,design 1
• features as CT 3000 O
technical specification
dimensions (H x Ø) 42 mm x 95 mm
art. 31929
optical smoke detector, black CT 3001 O black
conventional detector, complies with EN 54 part 7 specification,design 1
• features as CT 3000 O
technical specification
dimensions (H x Ø) 42 mm x 95 mm
art. 31926
www.detectomat.com
41
2.2 CT 3000 - conventional detectors
2. detectors
optical smoke detector, white CT 3005 O white
conventional detector, complies with EN 54 part 7 specification,design 5
• features as CT 3000 O• low profile available
Technische Daten
dimensions (H x Ø) 47 mm x 110 mm
art. 30551
optical smoke detector, silver CT 3005 O silverart. 30552
optical smoke detector, silver CT 3004 O silver
conventional detector, complies with EN 54 part 7 specification,design 4
• features as CT 3000 O• low profile available
Technische Daten
dimensions (H x Ø) 47 mm x 110 mm
art. 30546
conventional detector, complies with EN 54 part 7 specification,design 5
• features as CT 3000 O• low profile available
Technische Daten
dimensions (H x Ø) 47 mm x 110 mm
low profile version design mount in version: art. 31684
www.detectomat.com
42
2.2 CT 3000 - conventional detectors
2. detectors
optical smoke detector, white CT 3004 O white
conventional detector, complies with EN 54 part 7 specification,design 4
• features as CT 3000 O
technical specification
dimensions (H x Ø) 47 mm x 110 mm
art. 30545
heat detector CT 3000 T
conventional heat detector, complies with EN 54 part 5 specification
• high functional detection-system • intelligent analysis of the thermal sensor
technical specification
operation voltage 9 up to 33 V DCquiesent current 100 µAalarm current 20 mAopen collector output 15 mA for LED indicatorssensitivity 60°C rate of riseoperation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cprotection class IP 43housing color whitematerial ABSdimensions (H x Ø) 52 mm x 100 mmcomplies with EN 54 - 5
art. 30014
multisensor detector CT 3000 OT
conventional optical smoke and heat detector,complies with EN 54 part 5 and 7 specification
• high functional detection-system • intelligent analysis of the thermal sensor• intelligent analysis of the measuring chamber signal
technical specification
operation voltage 9 up to 33 V DCquiesent current 100 µAalarm current 20 mAopen collector output 15 mA for LED indicatorssensitivity < 0,15 dB / m
60° rate of riseoperation temperature -10°C up to +60°Chumidity max. 95 % RH / 40°Cprotection class IP 43housing color whitematerial ABSdimensions (H x Ø) 52 mm x 100 mmcomplies with EN 54 - 7, EN 54 - 5
art. 30022
www.detectomat.com
43
2.3 detector accessoires
2. detectors
detector base SDB 3000art. 30301
detector base, bridged SDBB 3000
base for all loop3000 detectors including a bridge if the detectorshould be removed from the socket, colour: white
• usable for loop3000 detectors• including LED indicator connection• space for additional cage clambs and modules
technical specification
operation temperature -10°C up to +60°Chousing color whitematerial ABSdimensions (H x Ø) 20 mm x 95 mm
art. 31959
detector base, silver SDB 3000 silver
similar to detector base SBD 3000 colour: silver
art. 30926
detector base, bridged SDBB 3000 silver
similar to detector base SDBB 3000 colour: silver
art. 32084
detector base, bridged SDBB 3000 black
similar to detector base SDBB 3000 colour: black
art. 32083
diode base CDBD 3000
usable for all detectors of the series loop3000 and CT, colour: white
• standard base for all detectors of the series loop3000 and CT• including LED indicator connection• space for additional modules
technical specification
operation temperature -10°C up to +60°Chousing color whitematerial ABSdimensions (H x Ø) 20 mm x 95 mm
art. 32114
detector base, black SDB 3000 black
similar to detector base SBD 3000 colour: black
art. 30523
usable for all detectors of the series loop3000 and CT, colour: white
• standard base for all detectors of the series loop3000 and CT• including LED indicator connection• space for additional modules
technical specification
operation temperature -10°C up to +60°Chousing color whitematerial ABSdimensions (H x Ø) 20 mm x 95 mm
www.detectomat.com
44
2.3 detector accessoires
2. detectors
detector relay base DRB 3000
detector base with integreated relay to connect to external devicescolour: white
• detector relays base to connect to external devices• the relay will be activated directly from the detector alarm output• potential-free change over contact
technical specification
relay output change over 30 V / 1 Aoperation temperature -10°C up to +60°Chousing color whitematerial ABSdimensions (H x Ø) 20 mm x 95 mmapprovals BMA 06/0363-A = pending
art. 30469
piezo buzzer for detectors Sockel Piezo
• additional buzzer for detectors of the series loop3000 and CT• activated by open collector output• noise volume 85 dB - distance 0,3 meter• powered by the detector
technical specification
operation voltage 15 up to 33 V DCnoise 85 dB / 0,3 moperation temperature -10°C up to +60°Chousing color whitematerial ABSdimensions (H x W x D) 8 mm x 45 mm x 35 mm
art. 32091
detector relay base DRB 3000 silver
similar to detector relay base DRB 3000 colour: silver
art. 32086
detector relay base DRB 3000 black
similar to detector relay base DRB 3000 colour: black
art. 32085
www.detectomat.com
45
2.3 detector accessoires
2. detectors
housing for air ducts LKMG
housing with test-box and sensor-pipe to monitore air streams withoptical detectors of the series loop3000 and CT
• including pipe for ingress and outlet air sampling• ingress of air pipe length: 210 mm• for air ducts up to 350 mm length• special lengths for ingress of air pipes possible• without detector base
technical specification
operation temperature -10°C up to +60°Cair speed 1 up to 25m/shousing colour greymaterial ABSdimensions (H x W x D) 200 mm x 110 mm x 92 mm
remarks:• it is essential to specifying the right base for this kit• no socket included
art. 31191
wall mount base adapter APS
usable as wall mount kit for all detector bases for on wall wire installations
• wire entries at the side• internal space for additional modules
technical specification
operation temperature -10°C up to +60°Chousing color whitematerial ABSdimensions (H x Ø) 28 mm x 110 mm
remarks:• it is essential to specifying the right base for this kit• no socket included
art. 31698
base for humid areas FRS
usable as wall mount kit for all detector bases for difficult and humid envirements
• universally applicable for damp locations• wire entries at the side• M25 screw fitting included
technical specification
operation temperature -10°C up to +60°Chousing color whitematerial ABSdimensions (H x Ø) 40 mm x 110 mm
remarks:• it is essential to specifying the right base for this kit• no socket included
art. 31181
www.detectomat.com
46
2.3 detector accessoires
2. detectors
base with heating APSB
usable as wall mount kit with monitored heating for all detectorbases for difficult and humid envoirements
• additional on-wall base with temperature controlled heating• usable in installations up to - 30°C
technical specification
operation voltage 24 V DCquiesent current 160 mAexternal user output 4W heatingoperation temperature -30°C up to +60°Chousing color whitematerial ABSweight 335 gdimensions (H x Ø) 55 mm x 110 mm
remarks:• it is essential to specifying the right base for this kit• no socket included
art. 31875
flush-mounting adapter white DR45W
usable as mount in kit to semi-recess detectors of the design 4 and5 in ceilings, color white
• flush mounting base kit for detectors design 4 and 5 of the series loop3000 and CT
• usable in installations in lower ceilings• ceiling hole diameter 120mm
technical specification
operation temperature -10°C up to +60°Chousing color whitematerial sheet steeldimensions (H x Ø) 35 mm x 165 mm
remarks: it is essential to specifying the right base for this kit
art. 32070
flush-mounting adapter silver DR45
usable as mount in kit to semi-recess detectors of the design 4 and5 in ceilings, color silver
• flush mounting base kit for detectors design 4 and 5 of the series loop3000 and CT
• usable in installations in lower ceilings• ceiling hole diameter 120mm
technical specification
operation temperature -10°C up to +60°Chousing color silvermaterial sheet steeldimensions (H x Ø) 35 mm x 165 mm
remarks: it is essential to specifying the right base for this kit
art. 31684
www.detectomat.com
47
2.3 detector accessoires
2. detectors
detector mounting adapter MKBD
for an distanced installation of all detector bases to ceilings or walls
• infinitely adjustable 270 to 480 mm• detector mounting-plate infinitely inclinable 0° until 110°
technical specification
colour light grey, RAL 7035material sheet steeldimensions (H x W x D) 135 mm x 100 mm x 270 - 480 mm
art. 30187
detector flap-mounting adapter MKK
for an distanced installation of all detector bases to ceilings or walls
• inclinable 0° until 110°
technical specification
colour light grey, RAL 7035material sheet steeldimensions (H x W x D) 150 mm x 117 mm x 13 - 154 mm
art. 30188
labelling tag for detector base MBC
usable for all detector bases of the series loop3000 and CTcolour: white
• fixing via plug in• selling-packages at 30 pieces
technical specification
operation temperature -10°C up to +60°Ccolour whitematerial ABSdimensions (H x W) 28 mm x 45 mm
art. 30479
www.detectomat.de
48
detector distance-mounting adapter MAK
for an distanced installation of all detector bases to ceilings or walls
• panel for mounting automatic fire detectors in lowered ceilings• ceiling distance 80 mm
technical specification
colour light grey, RAL 7035material sheet steeldimensions (H x W x D) 80 mm x 138 mm x 100 mm
art. 30189
wall bracket WA4
for an distanced installation of all detector bases to ceilings or walls
• for mounting of automatic fire detectors, for example over fire protected doors
• distance to the wall: 400 mm
technical specification
colour light grey, RAL 7035material sheet steeldimensions (H x W x D) 50 mm x 100 mm x 400 mm
art. 30190
wall bracket WA2
for an distanced installation of all detector bases to ceilings or walls
• for mounting of automatic fire detectors, for example over fire protected doors
• distance to the wall: 200 mm
technical specification
colour light grey, RAL 7035material sheet steeldimensions (H x W x D) 50 mm x 100 mm x 200 mm
art. 30191
2.3 detector accessoires
2. detectors
www.detectomat.de
49
3.1 loop3000 - addressable manual call points
3. manual call points
manual call point, ABS PL 3300 PBD-ABS-B
intelligent manual call point for loop3000, ABS, blue,with bidirectional isolator
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • multicolour-LED for alarm
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color bluematerial ABSdimensions (H x W x D) 125 mm x 125 mm x 35 mmapprovals VdS G 203021complies with EN 14655
art. 31059
manual call point, ABS PL 3300 PBDH-ABS-R
intelligent manual call point for loop3000, ABS, red,with bidirectional isolator
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • multicolour-LED for alarm
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color red, RAL 3000material ABSdimensions (H x W x D) 125 mm x 125 mm x 35 mmapprovals VdS G 203021complies with EN 14655
art. 31669
manual call point, ABS PL 3300 PBD-ABS-Y
intelligent manual call point for loop3000, ABS, yellow,with bidirectional isolator
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • multicolour-LED for alarm
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color yellowmaterial ABSdimensions (H x W x D) 125 mm x 125 mm x 35 mmapprovals VdS G 203021complies with EN 14655
art. 31060
www.detectomat.com
50
3.1 loop3000 - addressable manual call points
3. manual call points
manual call point, ALU PL 3300 PBDH-ALU-R
intelligent manual call point for loop3000, ALU, red,with bidirectional isolator
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • multicolour-LED for alarm
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color red, RAL 3000material aluminiumdimensions (H x W x D) 125 mm x 125 mm x 34 mmapprovals VdS G 203021complies with EN 14655
art. 31668
www.detectomat.com
51
3.1 loop3000 - addressable manual call points
3. manual call points
manual call point, ALU PL 3300 PBD-ALU-B
intelligent manual call point for loop3000, ALU, blue,with bidirectional isolator
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • multicolour-LED for alarm
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color bluematerial aluminiumdimensions (H x W x D) 125 mm x 125 mm x 34 mmcomplies with EN 14655
art. 31061
manual call point, ALU PL 3300 PBD-ALU-Y
intelligent manual call point for loop3000, ALU, yellow,with bidirectional isolator
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector • multicolour-LED for alarm
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color yellowmaterial aluminiumdimensions (H x W x D) 125 mm x 125 mm x 34 mmcomplies with EN 14655
art. 31062
manual call point, chinese PL 3300 MCP-kit
intelligent manual call point for loop3000, ALU red, labeled symbol:"Fire Alarm", with bidirectional isolator
• chinese version• 2 LED displays for operation and alarm • 1 output for evacuation systems • loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector
• multicolour-LED for alarm
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 250 µAalarm current 5 mAoperation temperature -10°C up to +60°Cprotection class IP42housing color red, RAL 3000material ABSdimensions (H x W x D) 125 mm x 125 mm x 34 mmcomplies with CCC
art. 30569
www.detectomat.com
52
3.1 loop3000 - addressable manual call points
3. manual call points
manual call point PL 3300 MCP-kit
intelligent manual call point for loop3000, ABS red, labeled symbol:"burning house", with bidirectional isolator
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator
• addressable spur connection via T-branch • a log of the last maintenance date is stored• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• outputs for alarm and fault condition indication at the detector
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 370 µAalarm current 5 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color red, RAL 3000material ABSdimensions (H x W x D) 88 mm x 88 mm x 54 mmapprovals LPCB 166b/8complies with EN 54
art. 32065
manual call point, ABS, red CT 3000 PBDH-ABS-R
conventional manual call point for the series CT3000
• LED indicator for alarm, housing ABS
technical specification
operation voltage 12 up to 24 V DCalarm current 27 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color red, RAL 3000material ABSdimensions (H x W x D) 125 mm x 125 mm x 34 mmapprovals VdS G296033complies with EN 54
art. 31675
3.2 CT 3000 - conventional call points
www.detectomat.com
53
3.2 CT 3000 - conventional call points
3. manual call points
manual call point, ABS, blue CT 3000 PBD-ABS-B
conventional manual call point for the series CT3000
• LED indicator for alarm, housing ABS
technical specification
operation voltage 12 up to 24 V DCalarm current 27 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color bluematerial ABSdimensions (H x W x D) 125 mm x 125 mm x 34 mmcomplies with EN 54
art. 31651
manual call point, ALU, red CT 3000 PBDH-ALU-R
conventional manual call point for the series CT3000
• LED indicator for alarm, housing aluminium
technical specification
operation voltage 12 up to 24 V DCalarm current 27 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color red, RAL 3000material aluminiumdimensions (H x W x D) 125 mm x 125 mm x 34 mmapprovals VdS G 202034complies with EN 54
art. 31676
manual call point, ALU, blue CT 3000 PBD-ALU-BD
conventional manual call point for the series CT3000
• LED indicator for alarm, housing aluminium
technical specification
operation voltage 12 up to 24 V DCalarm current 27 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color bluematerial aluminiumdimensions (H x W x D) 125 mm x 125 mm x 34 mmcomplies with EN 54
art. 31087
www.detectomat.com
54
3.2 CT 3000 - conventional call points
3. manual call points
manual call point, IP 66, red CT 3000 PDB-IP66-R
conventional manual call point for the series CT3000,IP 66 protected for critical envoirements
• LED indicator for alarm• housing ABS waterdust and proof IP 66• two switching contacts• connectable on loop3000 via AMD3311
technical specification
operation voltage 19 up to 28 V DCalarm current 20 mAoperation temperature -20°C up to +80°Cprotection class IP 66housing color red, RAL 3000material aluminiumdimensions (H x W x D) 135 mm x 145 mm x 70 mmapprovals VdS G 295025complies with EN 54
art. 31083
manual call point, ABS, red SBDH-ABS-R
conventional manual call point for the series CT3000
technical specification
operation voltage 9 up to 33 V DCalarm current 27 mAoperation temperature -10°C up to +60°Cprotection class IP 42housing color red, RAL 3000material ABSdimensions (H x W x D) 88 mm x 88 mm x 54 mmapprovals LPCB 166b/8complies with EN 54
art. 32082
manual call point, ALU, yellow CT 3000 PBD-ALU-YD
conventional manual call point for the series CT3000
• LED indicator for alarm, housing aluminium
technical specification
operation voltage 12 up to 24 V DCalarm current 27 mAoperation temperature -20°C up to +70°Cprotection class IP 42housing color yellowmaterial aluminiumdimensions (H x W x D) 125 mm x 125 mm x 34 mmapprovals VdS G 205 018complies with EN 54
art. 31088
www.detectomat.com
55
3.3 accessoires for manual call points
3. manual call points
weatherproof housing WG-R
in red for aluminium manual call points
• usable to reach protection level IP 54• including fitting kit
technical specification
housing color red, RAL 3000material aluminiumdimensions (H x W x D) 145 mm x 131 mm x 55 mm
art. 31091
weatherproof housing WG-B
in blue for aluminium manual call points
• usable to reach protection level IP 54• including fitting kit
technical specification
housing color bluematerial aluminiumdimensions (H x W x D) 145 mm x 131 mm x 55 mm
art. 31092
glass for manual call point HFM EG
• unlabeled dimensions (H x W) 80 mm x 80 mm
art. 31910
glass for manual call point HFM EG-B
• labeled with blue circle dimensions (H x W) 80 mm x 80 mm
art. 31069
glass for manual call point HFM EG-G
• labeled with yellow circle dimensions (H x W) 80 mm x 80 mm
art. 30026
key for manual call point HFM-SCH-Mart. 40054
in-/output module IOM 3311
intelligent input output module for loop3000 with bidirectional isolator in a housing
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • 1 monitored input to connect external devices to the loop3000• 1 potential-free output to control external devices• in- and output are freely programmable • automatic addressing (soft-addressing)• manual addressing (EasyCheck)• multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 500 µAalarm current 5 mArelay output change over 30 V / 1 Aoperation temperature -10°C up to +60°Cprotection class IP 54housing color grey, RAL 7035material ABSdimensions (H x W x D) 93 mm x 93 mm x 55 mmapprovals VdS G 205029complies with EN 54
art. 30200
extension module UBW 3311
extension module for the realisation of controlled outputs via theIOM3311 or the OMS3301
• 1 monitored output with broken wire- and short circuit monitoring
• maximum current 1 A via external supply• convenient for the monitored connection of signaling devices• directly connectable in the housing of the IOM3311 or OMS3301• external powered
technical specification
operation voltage 24V DCquiesent current 11 mAalarm current up to 1Asounder output up to 1Aoperation temperature -10°C up to +60°Cdimensions (H x W x D) 20 mm x 38 mm x 35 mmapprovals pendingcomplies with EN 54
art. 32073
www.detectomat.com
56
4. loop3000 modules
www.detectomat.com
57
4. loop3000 modules
mini in-/output module AMD 3311
intelligent input output module for loop3000 with bidirectional isolatorin mini version
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • 1 monitored input to connect external devices to the loop3000• 1 open collector output to control external devices• in- and output are freely programmable
• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• poured ciruit board version
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 370 µAalarm current 5 mAopen collector output 500 mAoperation temperature -10°C up to +60°Chousing color bluedimensions (H x W x D) 27 mm x 73 mm x 15 mm approvals VdS G 206047complies with EN 54
art. 30513
output module OMS 3301
intelligent sounder-control-module for loop3000 including bidirectional isolator
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch
• 1 potential-free output to control external devices• the relays can be reset at the fire control panel via
"external sounder on/off"• output is freely programmable • automatic addressing (soft-addressing)• manual addressing (EasyCheck)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 500 µAalarm current 5 mArelay output change over 30 V / 1 Aoperation temperature -10°C up to +60°Cprotection class IP 54housing color grey, RAL 7035material ABSdimensions (H x W x D) 93 mm x 93 mm x 55 mmapprovals VdS G 205030complies with EN 54
art. 30211
mini output module OMS 3301mini
intelligent sounder-control-module for loop3000 including bidirectionalisolator
• loop3000 is a high functional detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • 1 open collector output to control external devices• output is freely programmable
• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• poured ciruit board version
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 370 µAalarm current 5 mAopen collector output 500 mAoperation temperature -10°C up to +60°Chousing color bluedimensions (H x W x D) 27 mm x 73 mm x 15 mm complies with EN 54
art. 31640
www.detectomat.com
58
4. loop3000 modules
in-/output module mini AOM 3301
intelligent module for loop3000 including bidirectional isolator
• loop3000 is a high functionality detection-system• including bidirectional short circuit isolator• addressable spur connection via T-branch • 1 monitored input to connect external devices to the loop3000• 1 monitored output to control external devices• in- and output are freely programmable • automatic addressing (soft-addressing)• manual addressing (EasyCheck)• ciruit board version
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 370 µAalarm current 5 mAexternal user output 5 mA monitoredoperation temperature -10°C up to +60°Cdimensions (H x W x D) 27 mm x 73 mm x 15 mm complies with EN 54
art. 32074
conventional zone module TCM 3300
intelligent module for loop3000 for connection of 1 zone of conven-tional detectors, including bidirectional isolator
• detector zone interface with high functionality for loop3000• integrated bidirectional short circuit isolator• addressable spur connection via T-branch • variable adjustable of short circuit-, break wire-, pre-alarm- and
alarm threshold• external power supply of 12 / 24 volt• automatic addressing (soft-addressing)• manual addressing (EasyCheck)• multicolour-LED for alarm- (red) and fault-display (yellow)
technical specification
operation voltage 15 up to 30 V loop poweredquiesent current 500 µAalarm current 5 mA per zoneexternal user output 12 / 24 V 10 mA + zone currentoperation temperature -10°C up to +60°Cprotection class IP 54housing color grey, RAL 7035material ABSdimensions (H x W x D) 93 mm x 93 mm x 55 mmapprovals VdS G 206048complies with EN 54
art. 30205
www.detectomat.com
59
5. loop3000 - radio extension
wireless gateway WGW 3300
intelligent wireless gateway for loop3000 to connect wireless detectors/-modules, including bidirectional isolators
• a high functionality wireless extention to the loop3000• for the integration of wireless detectors and -modules• including bidirectional short circuit isolator as loop-module• programming and status is displayed by a 4 x 20 character display• keyboard consists of 16 keys for controlling and programming
• 5 radio-channels and 2 emergency-channels 433/868 MHz with changeover operation
• up to 32 wireless devices can be connected per gateway• analogue values of the detectors can be shown via the
detectomat fire control panel• the detectomat fire control panel can allocate the plaintext
and zones of the devices• meets the requirements of BS 5839, EN 54 and VdS• common alarm and fault relays for stand alone operation• separate current supply and emergency power supply• integrated emergency power supply by commercial standard
AA-batteries• up to 10 gateways in one radio nit can be integrated without
quality loss
technical specification
frequency 2 x 433 MHz, 5 x 868 MHzoperation voltage 24 V DC externalemergency power batteries 8 x AA Mignonquiesent current 20 mAdisplay 4 x 20 charactersrelay output alarm 30 V / 1 A
fault 30 V / 1 Aoperation temperature -10°C up to +60°Cprotection class IP 65housing color grey, RAL 7035material ABSdimensions (H x W x D) 200 mm x 120 mm x 77 mmapprovals VdS pending, LPCB,
E 120684/1.1, TE 226593complies with EN 54 - 25
art. 30025
wireless optical smoke detector WL 3200 O
intelligent wireless optical smoke detector for loop3000
• high functionality detection system for loop3000• equivilant to loop-device in conjunction with gateway WGW 3300 • power supplied by 2 pieces of commercial standard C-batteries• battery lifetime approximatley 3 years• a programmable piezo-sounder is included
technical specification
frequency 2 x 433 MHz, 5 x 868 MHzoperation voltage 3 V, 2 x MX1400 LR 14 Duracelloperation temperature -10°C up to +60°Cprotection class IP 42housing color whitematerial ABSdimensions (H x Ø) 65 mm x 100 mmapprovals VdS pending, LPCB,
E 120684/1.1, TE 226593complies with EN 54 - 7
art. 30003
www.detectomat.com
60
5. loop3000 - radio extension
antenna for extended range WGA 3200
external antenna for the wireless gateway WGW 3300
• antenna for the improvement of the radio-field quality and range in intricate area conditions
technical specification
dimensions (H x W x D) 490 mm x 270 mm x 330 mm
art. 32005
wireless input module WL 3210 EM
intelligent input module for loop3000
• high functionality detection system for loop3000
• equivilant to loop-device in conjunction with gateway WGW 3300 • stand-alone addressed during universal operation• power supplied by commercial standard A mignon• battery lifetime approximatley 3 years• 1 monitored input, freely programmable via the detectomat fire
control panel• integrated alarm-sound• an activation-module, e.g. a manual call point or a similar device
can be separated up to 5 m
technical specification
frequency 2 x 433 MHz, 5 x 868 MHzoperation voltage 3 V, 2 x MX1400 LR 14, Duracelloperation temperature -10°C up to +60°Cprotection class IP 54housing color grey, RAL 7035material ABSdimensions (H x W x D) 93 mm x 93 mm x 55 mmapprovals LPCB, E 120684/1.1, TE 226593complies with EN 54
art. 31627
www.detectomat.com
61
5. loop3000 - radio extension
radio field analyzer RFA 3000
with the possibility to switch between sending and receiving-mode
• radio filed intensity analyzer (1 pair)• to identify the best installation area of the detectomat
wireless devices• battery operated unit 2 x AA-batteries)• separate antenna for 433 and 868 MHz• LED signal strength gage-display• the measurements can be transferred to a personal computer
via a serial interface (optional)• LED display for sending, receiving and frequency-band
technical specification
frequency 20 x 433 MHz, 4 x 868 Hzoperation voltage 3 V, 2 x AAprotection class IP 30housing color grey, RAL 7035material ABSdimensions (H x W x D) 195 mm x 66 mm x 27 mm
art. 31626
www.detectomat.com
62
6.1 aspiration smoke detectors
6. special detectors
Stratos HSSD-2 standard detector HSSD-2 M
intelligent smoke detector for building a highly sensitive asiratingsmoke system for earliest fire detection
• for the earliest detection of fire by a laser-detector-chamber withpatented artificial intelligence "classifire"
• to monitor clean-rooms as well as contaminated areas and also in areas, which are used by vehicles with combustion motor
• highest sensitivity, optimal alarm threshold and low false alarm rates are ensured by the automatic adjustment to the respective area conditions
• sensitivity adjustable: 0,002 - 25 % obs/m• max. 1600 mÇ (one fire compartment) can be monitored• max. length of aspiration-pipes: 200 m with 100 bore holes or
250 m with 80 bore holes• LC display 2 x 16 characters, cursor key control panel• integrated dust filter meets the requirements of the VdS• up to 127 STRATOS devices can be connected in a network
by the integrated RS 485• uninterruptible external current supply 24 V DC
technical specification
operation voltage 24 V DCquiesent current 400 mAinterfaces RS 485display 2 x 16 charactersrelay output 3 (alarm, pre-alarm, fault)sensitivity (0,002 - 25) % obs / m
(0,0003 - 10) µmoperation temperature -10°C up to +60°Cprotection class IP 50housing color light greymaterial aluminiumdimensions (H x W x D) 372 mm x 427 mm x 95 mmapprovals VdS G 203024, LPCB, CCCcomplies with EN 54 - 13
remarks:• the project engineering guidelines of the manufacturer has
to be considered by the planning of the system • all project engineering documents have to be signed
by detectomat GmbH
art. 31114
Stratos HSSD-2 standard detector without display HSSD-2 MOD
intelligent smoke detector for building a highly sensitive asiratingsmoke system for earliest fire detection, without display
• for the earliest detection of fire by a laser-detector-chamber withpatented artificial intelligence "classifire"
• to monitor clean-rooms as well as contaminated areas and also in areas, which are used by vehicles with combustion motor
• highest sensitivity, optimal alarm threshold and low false alarm rates are ensured by the automatic adjustment to the respective area conditions
• sensitivity adjustable: 0,002 - 25 % obs/m• max. 1600 mÇ (one fire compartment) can be monitored• max. length of aspiration-pipes: 200 m with 100 bore holes or
250 m with 80 bore holes• LC display for operation, alarm and fault• integrated dust filter meets the requirements of the VdS• up to 127 STRATOS devices can be connected in a network by
the integrated RS 485• uninterruptible external current supply 24 V DC
technical specification
operation voltage 24 V DCquiesent current 400 mAinterfaces RS 485zone LED´s 4 x LED indicators for operation,
alarm, faultrelay output 3 (alarm, pre-alarm, fault)sensitivity (0,002 - 25) % obs / m
(0,0003 - 10) µmoperation temperature -10°C up to +60°Cprotection class IP 50housing color light greymaterial sheet steeldimensions (H x W x D) 372 mm x 427 mm x 105 mmapprovals VdS G 203 024complies with EN 54 - 13
art. 31867
Stratos HSSD-2 control module 19" HSSD-2 S 19"
command module in 19" for programming and displaying all in thenetwork connected STRATOS components
• LC display 8 x 16 characters, cursor key control panel• up to 127 STRATOS devices can be connected in a network by
the integrated RS 485• uninterruptible external current supply 24 V DC
technical specification
operation voltage 24 V DCquiesent current 450 mAinterfaces RS 485display 8 x 16 Zeichenoperation temperature -10°C up to +60°Cprotection class IP 50housing color greymaterial aluminiumdimensions (H x W x D) 3HE mm x 19“ x 95 mmapprovals VdS G 203024, LPCB, CCCcomplies with EN 54 - 13
remarks: without housing
art. 31953
www.detectomat.com
63
6.1 aspiration smoke detectors
6. special detectors
Stratos HSSD-2 standard detector and control module HSSD-2 M-S
intelligent smoke detector for building a highly sensitive asiratingsmoke system for earliest fire detection, including command module
• for the earliest detection of fire by a laser-detector-chamber withpatented artificial intelligence "classifire"
• with the command module all networking STRATOS devices of one system can be programmed as well as there status can be displayed
• to monitor clean-rooms as well as contaminated areas and also in areas, which are used by vehicles with combustion motor
• highest sensitivity, optimal alarm threshold and low false alarm rates are ensured by the automatic adjustment to the respective area conditions
• sensitivity adjustable: 0,002 - 25 % obs/m• max. 1600 mÇ (one fire compartment) can be monitored• max. length of aspiration-pipes: 200 m with 100 bore holes or
250 m with 80 bore holes• LC display 8 x 16 characters, cursor key control panel• integrated dust filter meets the requirements of the VdS• up to 127 STRATOS devices can be connected in a network by
the integrated RS 485• uninterruptible external current supply 24 V DC
technical specification
operation voltage 24 V DCquiesent current 400 mAinterfaces RS 485display 8 x 16 charactersrelay output 3 (alarm, pre-alarm, fault)sensitivity (0,002 - 25) % obs / m
(0,0003 - 10) µmoperation temperature -10°C up to +60°Cprotection class IP 50housing color greymaterial aluminiumdimensions (H x W x D) 372 mm x 427 mm x 95 mmapprovals VdS G 203024, LPCB, CCCcomplies with EN 54 - 13
remarks:• the project engineering guidelines of the manufacturer has
to be considered by the planning of the system • all project engineering documents have to be signed
by detectomat GmbH
art. 31115
Stratos HSSD-2 control module HSSD-2 S
command module for programming and displaying all in the networkconnected STRATOS components
• LC display 8 x 16 characters, cursor key control panel• up to 127 STRATOS devices can be connected in a network by
the integrated RS 485• uninterruptible external current supply 24 V DC
technical specification
operation voltage 24 V DCquiesent current 450 mAinterfaces RS 485display 8 x 16 Zeichenoperation temperature -10°C up to +60°Cprotection class IP 50housing color greymaterial aluminiumdimensions (H x W x D) 372 mm x 427 mm x 95 mmapprovals VdS G 203024, LPCB, CCCcomplies with EN 54 - 13
art. 31117
www.detectomat.com
64
6.1 aspiration smoke detectors
6. special detectors
Stratos Micra 100 including mounting base Micra 100
intelligent aspirating smoke system for building a highly sensitiveasirating smoke system for earliest detection, without display
• for the earliest detection of fire by a laser-detector-chamber withpatented artificial intelligence "classifire"
• to monitor clean-rooms as well as contaminated areas and also in areas, which are used by vehicles with combustion motor
• highest sensitivity, optimal alarm threshold and low false alarm rates are ensured by the automatic adjustment to the respective area conditions
• sensitivity adjustable: 0,002 - 25 % obs/m
• max. length of aspiration-pipes: 100 m (2 x 50 m, each with max. 25 bore holes)
• LC display for operation, alarm, fault• integrated dust filter • up to 127 STRATOS devices can be connected in a network by
the integrated RS 485• uninterruptible external current supply 24 V DC• mounting base including connecting flange to ensure the
recirculation
technical specification
operation voltage 26 V DCquiesent current 400 mAinterfaces RS 485zone LED´s 4 x LED indicators for operation,
alarm, faultrelay output 3 (alarm, pre-alarm, fault)sensitivity (0,002 - 25) % obs/m
(0,0003 - 10) µmoperation temperature -10°C up to +60°Cprotection class IP 51housing color greymaterial aluminiumdimensions (H x W x D) 180 mm x 300 mm x 85 mmapprovals LPCBcomplies with EN 54 - 13
art. 31476
Stratos Micra 25 including mounting base Micra 25
intelligent aspirating smoke system for building a highly sensitiveasirating smoke system for earliest detection, without display
• for the earliest detection of fire by a laser-detector-chamber withpatented artificial intelligence "classifire"
• to monitor clean-rooms as well as contaminated areas and also in areas, which are used by vehicles with combustion motor
• highest sensitivity, optimal alarm threshold and low false alarm rates are ensured by the automatic adjustment to the respective area conditions
• sensitivity adjustable: 0,002 - 25 % obs/m
• max. length of aspiration-pipes: 50 m (25 m at highest sensitivity)
• LC display for operation, alarm, fault• integrated dust filter • up to 127 STRATOS devices can be connected in a network by
the integrated RS 485• uninterruptible external current supply 24 V DC• mounting base including connecting flange to ensure the
recirculation
technical specification
operation voltage 26 V DCquiesent current 250 mAinterfaces RS 485zone LED´s 3 x LED indicators for operation,
alarm, faultrelay output 3 (alarm, pre-alarm, fault)sensitivity (0,002 - 25) % obs/m
(0,0003 - 10) µmoperation temperature -10°C up to +60°Cprotection class IP 51housing color greymaterial aluminiumdimensions (H x W x D) 175 mm x 135 mm x 80 mmapprovals LPCBcomplies with EN 54 - 13
art. 31118
www.detectomat.com
65
6.1 aspiration smoke detectors
6. special detectors
6.2 accessoires for smoke detectors
aspiration smoke detector ASD-20
aspiration housing to insert one or two conventional or addressableoptical smoke detectors
• applicable in the serial loop3000 and CT 3000 • directly connectable to the loop3000 with IOM 3311• 2 outputs for alarm and one fault relays• pipe system with 25 mm pipe connectable, maximum length 100 m • the aspiration pipe is permanent monitored • LED display for operation, alarm and fault• dust filter is included in the delivery • uninterruptible external current supply 24 V DC
technical specification
input voltage 24 V DCoperation temperature -10°C up to +60°Cstock temperature -10°C up to +70°Chumidity < 95 %housing color grey, RAL9999weight 4000 gmaterial polycarbonatdimensions (H x W x D) 314 mm x 254 mm x 115 mm
remarks: apirating pipe systems made of PVC are applicable and canbe ordered by the local wholesalers
art. 30078
Stratos asirating pipe 3/4" STR-R
halogen-free aspiration-pipe for STRATOS aspiration smoke system
• 3 m pipe• material plastic, halogen-free, red• low coefficient of thermal expansion • great flexibility at high capacity• refractiveness against chemicals
technical specification
colour rotmaterial ABS,dimensions (H x Ø) 3 m x 3/4"
art. 31133
aspiration smoke detector ASD-01
aspiration housing to insert one or two conventional or automaticdetectors
• applicable in the serial loop3000 and CT 3000 • directly connectable to the loop3000 with IOM 3311• 2 outputs for alarm and one fault relays• pipe system with 25 mm pipe connectable, maximum length 50 m • the aspiration pipe is permanent monitored • LED display for operation, alarm and fault• dust filter is included in the delivery • uninterruptible external current supply 24 V DC
technical specification
input voltage 24 V DCoperation temperature -10°C up to +60°Chumidity 10 up to 95 % RHdimensions (H x W x D) 165 mm x 250 mm x 240 mm
remarks: apirating pipe systems made of PVC are applicable and canbe ordered by the local wholesalers
art. 32076
www.detectomat.com
66
6.2 accessoires for smoke detectors
6. special detectors
Stratos 45° deg elbow pipe STR-W45
technical specification
colour redmaterial ABSdimensions (Ø) 3/4"
art. 31135
Stratos 90° bend STR-B90
technical specification
colour redmaterial ABSdimensions (Ø) 3/4"
art. 31136
Stratos socket STR-M
technical specification
colour redmaterial ABSdimensions (Ø) 3/4"
art. 31138
Stratos T-piece STR-T
technical specification
colour redmaterial ABSdimensions (Ø) 3/4"
art. 31140
Stratos socket union STR-V
technical specification
colour redmaterial ABSdimensions (Ø) 3/4"
art. 31141
Stratos end cap STR-E
technical specification
colour redmaterial ABSdimensions (Ø) 3/4"
art. 31143
www.detectomat.com
67
6.2 accessoires for smoke detectors
6. special detectors
Stratos adapter 3/4" female to 25 mm male STR-R3/4”-25
technical specification
colour redmaterial ABSdimensions (Ø) 3/4" x 25 mm
art. 31948
Stratos 25 mm female to 3/4" male adapter STR-R26-3/4”
technical specification
colour redmaterial ABSdimensions (Ø) 25 mm x 3/4"
art. 31949
Stratos socket 3/4" to 25 mm female STR-RM5
technical specification
colour redmaterial ABSdimensions (Ø) 3/4" x 25 mm
art. 31950
Stratos ABS-socket 3/4" to 25 mm STR-RH
technical specification
colour blackmaterial ABSdimensions (Ø) 3/4" x 25 mmapprovals VdS G 206 034
art. 32050
Stratos plug sampling point assembly STR-SK
technical specification
colour whitematerial ABSdimensions (Ø) 3/4"
art. 31613
www.detectomat.de
68
6.2 accessoires for smoke detectors
6. special detectors
Stratos patress sampling point STR-KB
Mit Befestigungsflasch
technical specification
colour whitematerial ABSdimensions (Ø) 3/4"
art. 31156
Stratos in-line smapling point STR-KK
technical specification
colour whitematerial ABSdimensions (Ø) 3/4"
art. 31155
Stratos in-line remote sampling point adapter STR-MK
technical specification
colour redmaterial ABSdimensions (Ø) 3/4" - 10 mm
art. 31153
Stratos end cap adaptor STR-EK
technical specification
colour redmaterial ABSdimensions (Ø) 3/4" - 10 mm
art. 31154
Stratos nylon tube, red STR-KR
technical specification
housing color redmaterial Nylondimensions (Ø) 10 mm - 3/4"
art. 31151
www.detectomat.com
69
6.2 accessoires for smoke detectors
6. special detectors
Stratos pipe clip black STR-CA
M8 x 60 mm
art. 31146
Stratos flange nut STR-CMart. 31960
Stratos pipe cleaner STR-RE
500 ml
art. 31148
Stratos ABS solvent cement STR-SK
for ABS-pipe, 250 ml
art. 31147
Stratos sampling hole warning stickers STR-WA
to mark the aspiration drilling points, Selling-packages at 100 pieces
art. 31149
Stratos nylon tube, white STR-KW
technical specification
color whitematerial nylondimensions (Ø) 10 mm
art. 31152
Stratos pipe clip, red STR-C
technical specification
color redmaterial ABS
art. 31145
www.detectomat.com
70
6.3 infrared beam detectors
6. special detectors
infrared beam detector SPB-E IR BD
sender- and receiver unit
• connectable on the loop3000 via IOM3311• light and dark smoke can be detected
• range 5 - 100 m• monitored area and mounting meets DIN VDE 0833• potential-free relays for alarm and fault • three sensitivities: 25, 50 and 70 %
technical specification
operation voltage 15 up to 33 V DCquiesent current 280 µAalarm current 20 mArelay output 2operation temperature -10°C up to +50 °Chumidity max. 95 %housing color whitematerial ABSweight transmitter 450 g, reciever 450 gdimensions (H x W x D) 145 mm x 100 mm x 86 mmapprovals VdS G 295004
art. 30473
infrared beam detector FR 2000
sender, receiver and separate analyser
• connectable on the loop3000 via IOM3311
• light and dark smoke can be detected• range 5 - 100 m• monitored area and mounting meets DIN VDE 0833• potential-free relays for alarm and fault • three sensitivities: 25, 35 and 50 %
technical specification
operation voltage 11,5 up to 28 V DCquiesent current 14 mAalarm current 22 mArelay output 2 x 30 V DC / 1 Aoperation temperature -20°C up to +55° Cstock temperature -25°C up to +60°Cprotection class IP 50housing color greycolour Frontfolie greymaterial sheet steelweight control unit 2140 gdimensions (H x W x D) 265 mm x 210 mm x 85 mmapprovals VdS G 297058complies with EN 54 - 12
art. 31095
reset module RM95
reset-board for the use in the loop to control the SB-E IR BD • by voltage supply interruption the external detectors can be reset• for a system compatible resetting of the detector after abrogate
the alarm criterion• to connect to the opto-output of the input-module • circuit board with connectin clamp included in delivery
art. 31096
www.detectomat.com
71
6.3 infrared beam detectors
6. special detectors
infrared beam detector FR 50 RV
sender and receiver in a single housing including one prism
• connectable on the loop3000 via IOM3311• light and dark smoke can be detected
• range 5 - 50 m• monitored area and mounting meets DIN VDE 0833• potential-free relays for alarm and fault • three sensitivities: 25, 35 and 50 %
technical specification
operation voltage 10,2 up to 30 V DCquiesent current 4 mAalarm current 15 mArelay output 2 x 30 V DC / 1 Aoperation temperature -30°C up to +55°Cstock temperature -35°C up to +60°Cprotection class IP 50housing color greymaterial ABS weight 670 gdimensions (H x W x D) 117 mm x 210 mm x 120 mmapprovals VdS G 203070complies with EN 54 - 12
art. 31861
infrared beam detector SRA-ET IR BD-R
sender and receiver in a single housing including reflector
• connectable on the loop3000 via TCM3300• light and dark smoke can be detected• range 5 - 30 m
• monitored area and mounting meets DIN VDE 0833• conventional detector (current increase)
technical specification
operation voltage 15 up to 30 V DCquiesent current 350 µAalarm current 50 mAoperation temperature -10°C up to +50°Chumidity max. 95 %housing color whitematerial ABSweight 700 gdimensions (H x W x D) 125 mm x 122 mm x 80 mmapprovals VdS G 200080
art. 30474
infrared beam detector FR 100 RV
sender and receiver in a single housing including four prism
• connectable on the loop3000 via IOM3311• light and dark smoke can be detected• range 5 - 100 m• monitored area and mounting meets DIN VDE 0833• potential-free relays for alarm and fault • three sensitivities: 25, 35 and 50 %
(picture similar to art. 31861)
technical specification
operation voltage 10,2 up to 30 V DCquiesent current 4 mAalarm current 15 mArelay output 2 x 30 V DC / 1 Aoperation temperature -30°C up to +55°Cstock temperature -35°C up to +60°Cprotection class IP 50housing color greymaterial ABS weight 670 gdimensions (H x W x D) 117 mm x 210 mm x 120 mmapprovals VdS G 203070
art. 31486
www.detectomat.com
72
6.4 sensor cable detectors
6. special detectors
sensor cable detector SKM-03.01
sensor cable detector for the earliest detection of fire oder overheatin critical envoirements
• connectable on the loop3000 via IOM3311• display unit to connect up to 300 m sensor cable• appropriate to use in adverse surroundings or restricted
circumstances (underground car parks, cable channels, etc.)• potential-free alarm -and fault output• delivery including cable installation box• alarm display meets DIN 14623
technical specification
operation voltage 24 V DCquiesent current 28 mAalarm current 58 mArelay output 2 x 30 V DC / 1 Aoperation temperature -25°C up to +50°Cprotection class IP 65housing color greymaterial ABSweight 370 gdimensions (H x W x D) 105 mm x 105 mm x 65 mmapprovals VdS G 203067
art. 30503
sensor cable red SKM-KRT
to connect to sensor cable detector SKM 03
• appropriate in normal surrounding conditions without aggressive atmosphere
• tensile strength: < 200 N
• design: synthetic-coaxial wire,• diameter Ø 3,25 mm,• color red
approvals VdS G 203067, VdS G 203 077
art. 30980
sensor cable black SKM-KSW
to connect to sensor cable detector SKM 04
• appropriate in surrounding conditions with aggressive atmosphere
• tensile strength: < 200 N
• design: synthetic-coaxial wire,• diameter Ø 4 mm,• color black• protected against acids and bases
approvals VdS G 203067, VdS G 203 077
art. 30981
fanstening clamp SK-LS
for sensor cable detector
• to connect the sensor cable • time-saving and simple start-up mounting• hole diameter Ø 6mm• selling-packages at 100 pieces
art. 31620
www.detectomat.com
73
6.5 flame detectors
6. special detectors
ultraviolet flame detector FL 80/1A
ultraviolet flame detector for an earliest fire detection in the industrial areas and in difficult envoirements
• for the detection of open fire without smoke development• integrated test-unit to check the detector function during operation• sikh angle 90°-100°• sensibility meets EN 54-10 class 1• high speed capability
technical specification
input voltage 24 V DC ± 25 %operation voltage 24 V DCquiesent current 45 mAalarm current 70 mArelay output 2 x 30 V / 1Aoperation temperature -20°C up to +80°Cprotection class IP 54housing color redmaterial aluminium weight 1400 gdimensions (H x W x D) 155 mm x 120 mm x 110 mmapprovals VdS G 28425intriscally safe class Germanischer Loyd
art. 31897
ultraviolet flame detector FL 800/24V-K-N
ultraviolet flame detector for an earliest fire detection in the industrial areas and in difficult envoirements
• for the detection of open fire without smoke development• sikh angle variable 30°, 60° and 90°• sensibility meets EN 54-10 class 1• high speed capability
technical specification
input voltage 19,2 up to 28,8 Voperation voltage 24 V DC quiesent current 26 mAalarm current 46 mArelay output 2 x 30 V / 1Aoperation temperature -25°C up to +70°Chousing color greyprotection class IP 54material PC-LEXANweight 800 gdimensions (H x W x D) 200 mm x 150 mm x 150 mm
art. 31896
ultraviolet flame detector X 2200
ultraviolet flame detector to ensure the detection of non-hydrocarbonfires in industrial applications such as turbines, hydrogen,ammunition, silane
• automatic, optical self-testing• reliable detection even in case of more than one fault at
the same time • detects a n-heptane fire of 0,1m2 size until a distance of 18 metres• high speed capability • sikh angle 90°• tricolour LED indicates normal operation, fire and fault conditions• mounting plate vibration-free after MIL• event monitoring over built-in data logging • maintenance mode over magnet• modular housing design
technical specification
operation voltage 18 up to 30 V DCquiesent current 104 µAalarm current 253 mAinterfaces RS485, 4-20mArelay output 2x alarm, 1x faultsensitivity N-Heptan: 0,1 mÇ in 18 m
distance: 1 secMethan: 30 inch flame in 21 mdistance: 1 sec
operation temperature -40°C up to +75°Cstock temperature -55°C up to +85°Chumidity 0 up to 95 % - shortly 100 %
humidity in airprotection class IP 66housing color redmaterial aluminium weight 2700 gdimensions (H x W x D) 119 mm x 122 mm x 246 mmapprovals VdS G 203083intriscally safe class 0538 Ex II 2 GD, ATEX 132195,
FM3260
remarks: a shielded cable with a conductor cross section of 0,5mm2
to 2,5mm2 is recommended
art. 30477
www.detectomat.com
74
6.5 flame detectors
6. special detectors
infrared flame detector X 9800
infrared flame detector to ensure the detection of hydrocarbon fires inindustrial applications such as turbines, petrochemie, automotiveindustry, projects with high contamination
• automatic, optical self-testing• microprocessor controlled heated optics• reliable detection even in case of more than one fault at
the same time • detects a n-heptane fire of 0,1m2 size until a distance of 15 metres• high speed capability - 40 milliseconds• sikh angle 90°• tricolour LED indicates normal operation, fire and fault conditions• mounting plate vibration-free after MIL• event monitoring over built-in data logging • maintenance mode over magnet• modular housing design
technical specification
operation voltage 18 up to 30 V DCquiesent current 87,5 µAalarm current 550 mAinterfaces RS485, 4-20mArelay output 2x alarm, 1x faultsensitivity N-Heptan: 0,1 mÇ in 15 m
distance: less than 15 secMethan: 30 inch flame in 10,5 m distance: less than 10 sec
operation temperature -40°C up to +75°Cstock temperature -55°C up to +85°Chumidity 0 up to 95 % - shortly 100 %
humidity in airprotection class IP 66housing color redmaterial Aluminiumweight 2700 gdimensions (H x W x D) 119 mm x 122 mm x 246 mmapprovals VdS G 203084intriscally safe class 0538 Ex II 2 GD, ATEX 132195,
FM3260
remarks: a shielded cable with a conductor cross section of 0,5mm2
to 2,5mm2 is recommended
art. 32075
www.detectomat.com
75
6.5 flame detectors
6. special detectors
6.6 intrisically safe detectors
ex-ionisation smoke detector IRM Ex S60
conventional ionisation smoke detector in ex-proof design
• two-chamber principle• Am 241 as radioactive source
• radiation 33,3 kBq• wind speed 10 m per second
technical specification
operation voltage 17 up to 28 V DCquiesent current 30 µA by 20 V DCoperation temperature -10°C up to +60°Chumidity 0 - 95 %housing color whitematerial ABSdimensions (H x Ø) 42 mm x 100 mmEx BAS02, ATEX1288approvals VdS G 298 044intriscally safe class BAS02, ATEX1288
art. 31163
ultraviolet/infrared flame detector Eye 20/20 L
ultraviolet/infrared flame detector with combined analysis on UV andIR basis for the safe and failure-free detection of fires
• ultraviolet-infraret dual sensor• reliable detection even in case of more than one fault at
the same time
• environment-specific programming• high speed capability • sikh angle 90° horizontal and vertically• manual and automatic inserting test mode• high false alarm security• modular housing design
technical specification
operation voltage 18 up to 32 V DCquiesent current 100 mAalarm current 150 mAinterfaces 4-20mArelay output 2x alarm, 1x faultsensitivity N-Heptan 15m, Methan 5m,
Benzin 15m, Diesel 11m,Kerosin 11m, 5 sec.
operation temperature -40°C up to +70°Cstock temperature -55°C up to +85°Chumidity up to 95 % protection class IP 66housing color greymaterial aluminiumweight 3700 gdimensions (H x W x D) 132 mm x 132 mm x 120 mmapprovals pendingintriscally safe class ATEX EX II 2G, EExd IIB, FM, CSA,
ATEX, Gost R und GostK
art. 32077
www.detectomat.com
76
6.6 intrisically safe detectors
6. special detectors
ex-heat detector WM Ex S60
conventional thermal detector in ex-proof design, class 1
• two temperature sensors• maximal und differentiated triggering
technical specification
operation voltage 17 up to 28 V DCquiesent current 30 µA by 20 V DCoperation temperature -10°C up to +60°Chumidity 0 - 95 %housing color whitematerial ABSdimensions (H x Ø) 42 mm x 100 mmapprovals VdS G 298 047intriscally safe class BAS02, ATEX1288
art. 31164
base for ex-detector Meldersockel Ex
detector base in ex-proof design
technical specification
operation temperature -10°C up to +60°Chousing colour whitematerial ABSdimensions (H x Ø) 20 mm x 95 mmintriscally safe class BAS02, ATEX1288
art. 31169
ex-barrier Ex-B1
designed for ex-detectors in one ex detector zone
• including reverse battery protection • for top hat rail mounting
technical specification
quiesent current 6 mAoperation temperature -10°C up to +60°Chousing color greenmaterial ABSdimensions (H x W x D) 93 mm x 20 mm x 110 mm
art. 31174
www.detectomat.com
77
6.6 intrisically safe detectors
6. special detectors
ex manual call point HFM S65 , Ex
conventional ex-proof manual call point
• for ex-areas until zone 0• for using without ex-barrier
technical specification
operation voltage 19 up to 28 V DCalarm current 20 µAoperation temperature -20°C up to +80°Cprotection class IP 66housing color redmaterial ABSdimensions (H x W x D) 145 mm x 135 mm x 70 mmapprovals VdS G 295026intriscally safe class BAS02, ATEX1288
art. 31170
ex multiple tone sounder DB 5
conventional ex-proofen sounder
• included DIN tone meets DIN 33404• 26 different tones adjustable• usable with ex barrier only
technical specification
operation voltage 24 V DCalarm current 12 mAsounder output 100 dBoperation temperature -10°C up to +60°Cprotection class IP 65housing color reddimensions (H x Ø) 102 mm x 90 mmintriscally safe class BASEEFA-No. 92C2014
Klasse: Eex ia II C
art. 30217
ex-barrier SB SE/24 Ex
designed for ex-sounder DB 5
• electrically particularly designed for ex multiple tone sounder DB5
• DIN top hat rail mounting in housing Ex-H• each sounder needs one barrier
technical specification
operation temperature -10°C up to +60°Chousing colour greenmaterial ABSquiesent current 6 mAdimensions (H x W x D) 93 mm x 20 mm x 110 mm
art. 30219
www.detectomat.com
78
6.6 intrisically safe detectors
6. special detectors
ex-beacon, red BE 24 R EEx
conventional ex-proofen beacon, red
• beacon Ex, 24 V DC, red • with yellow aluminium housing and red cover• all purposes beacon with high light performance • stainless steel to protect the cover• flash energy: 15 Joule
technical specification
operation voltage 24 V DCalarm current 1,0 Aoperation temperature -20°C up to +40°Cprotection class IP 67housing color redmaterial aluminiumdimensions (H x Ø) 243 mm x 110 mmintriscally safe class II 2G EEx de IIC T6
art. 31222
housing for ex-modules M-1
to integrate ex-barriers, overload protection components and modules for top had rail mounting
• to integrate ex-barriers and protocol-interfaces• on-wall mounting• including 35 mm norm rail, which meets DIN EN 50022• up to 5 barriers can be included
technical specification
protection class IP 65housing color greymaterial ABSdimensions (H x W x D) 220 mm x 125 mm x 162 mm
art. 30218
ex-beacon, yellow BE 24 Y EEx
conventional ex-proofen beacon, yellow
• beacon Ex, 24 V DC, yellow• with yellow aluminium housing and yellow cover• all purposes beacon with high light performance • stainless steel to protect the cover• flash energy: 15 Joule
technical specification
operation voltage 24 V DCalarm current 1,0 Aoperation temperature -20°C up to +40°Cprotection class IP 67housing color yellowmaterial aluminiumdimensions (H x Ø) 243 mm x 110 mmintriscally safe class II 2G EEx de IIC T6
art. 31223
www.detectomat.com
79
7. home smoke detectors
optical home detector HDv 3000 O
battery powerd optical home detector for detection and alarming in domestic applications
• optical smoke detector for the early detection of smoke private living areas
• integreated pre alarm levels for an early smoke verification
• automatic fault monitoring of the measuring chamber as well as the battery voltage
• the acoustic alert is made by an integrated piezo alarm-sounder (> 85 dB)
• a visual and audiable low battery condition is signalled for 30 days
• up to 40 detectors can be interlinked for reporting fault and alarm conditions
• the optional plug-in radio module interface offers radio interlinking for reporting fault and alarm conditions via (433 MHz and/or. 868 MHz)
• the average life span with a 9 V alkaline battery is approximatly 2 years (without interlinking or alarms at 20°C ambient temperature)
• the pack includes the detector base, battery, screws and anchors
technical specification
operation voltage 9V DCquiesent current < 16 µAalarm current 5 mAinterfaces radio link and wire link interfacesensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity 95 % RH / 40°Cair speed max. 20 m / shousing colour whitematerial ABSweight 160 gdimensions (H x Ø) 51 mm x 100 mmapprovals VdS G 202042complies with DIN 14604
remarks: for the usage of radio modules a lithium ion battery isrecommended
art. 30458
optical home detector HD 3001 O white
battery powerd optical home detector for detection and alarming in domestic applications
• features as HDv 3000 O
technical specification
operation voltage 9V DCquiesent current < 16 µAalarm current 5 mAinterfaces radio link and wire link interfacesensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity 95 % RH / 40°Cair speed max. 20 m / shousing colour whitematerial ABSweight 140 gdimensions (H x Ø) 42 mm x 95 mmapprovals VdS G 202054 EN 14604
art. 30023
www.detectomat.com
80
7. home smoke detectors
optical home detector HD 3001 O black
simlilar to HDv 3000 O, design 1, black
• features as HDv 3000 O
technical specification
operation voltage 9 V DCquiesent current < 16 µAalarm current 5 mAinterfaces radio link and wire link interfacesensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity 95 % RH / 40°Cair speed max. 20 m / shousing colour blackmaterial ABSweight 140 gdimensions (H x Ø) 42 mm x 95 mmapprovals VdS G 202054 EN 14604
art. 30123
optical home detector HD 3004 O white
simlilar to HDv 3000 O, design 4, white
• features as HDv 3000 O
technical specification
operation voltage 9 V DCquiesent current < 16 µAalarm current 5 mAinterfaces radio link and wire link interfacesensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity 95 % RH / 40°Cair speed max. 20 m / shousing colour whitematerial ABSweight 140 gdimensions (H x Ø) 56 mm x 110 mmapprovals VdS G 202090 EN 14604
art. 31837
optical home detector HD 3001 O silver
simlilar to HDv 3000 O, design 1, silver
• features as HDv 3000 O
technical specification
operation voltage 9 V DCquiesent current < 16 µAalarm current 5 mAinterfaces radio link and wire link interfacesensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity 95 % RH / 40°Cair speed max. 20 m / shousing colour silvermaterial ABSweight 140 gdimensions (H x Ø) 42 mm x 95 mmapprovals VdS G 202054 EN 14604
art. 30024
www.detectomat.com
81
7. home smoke detectors
optical home detector HD 3005 O white
simlilar to HDv 3000 O, design 5, white
• features as HDv 3000 O
technical specification
operation voltage 9 V DCquiesent current < 16 µAalarm current 5 mAinterfaces radio link and wire link interfacesensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity 95 % RH / 40°Cair speed max. 20 m / shousing colour whitematerial ABSweight 160 gdimensions (H x Ø) 56 mm x 110 mmapprovals VdS G 202091 DIN 14604
art. 32015
optical home detector HD 3005 O silver
simlilar to HDv 3000 O, design 5, silver
• features as HDv 3000 O
technical specification
operation voltage 9 V DCquiesent current < 16 µAalarm current 5 mAinterfaces radio link and wire link interfacesensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity 95 % RH / 40°Cair speed max. 20 m / shousing colour silvermaterial ABSweight 160 gdimensions (H x Ø) 56 mm x 110 mmapprovals VdS G 202091 EN 14604
art. 32004
optical home detector HD 3004 O silver
simlilar to HDv 3000 O, design 4, silver
• features as HDv 3000 O
technical specification
operation voltage 9 V DCquiesent current < 16 µAalarm current 5 mAinterfaces radio link and wire link interfacesensitivity < 0,15 dB / moperation temperature -10°C up to +60°Chumidity 95 % RH / 40°Cair speed max. 20 m / shousing colour silvermaterial ABSweight 160 gdimensions (H x Ø) 56 mm x 110 mmapprovals VdS G 202090 DIN 14604
art. 31914
wireless fire control panel RCP 6
microprcessor controlled radio panel to control home detetectors bywireless network over 433 MHz
• working area in frequency band 433 MHz• 6 zones• connection up to 100 home smoke detectors via the module
433 MHz
• 4 potential-free outputs, freely programmable • a separate 230 V plug power-pack is included in the delivery• emergency batteries 8 x 1,5 V are included • LCD display
technical specification
input voltage 230 V ACfrequency 50 / 60 Hzoperation voltage 12 V ACemergency power 8 x 1,5 V batteriesquiesent current 30 mAalarm current 50 mAdisplay LCDzone LED´s 6 zonesrelay output 4 x change over contactoperation temperature 0°C up to +60°Cstock temperature -10°C up to +60°Chumidity max. 70 %protection class IP 20housing colour / front colour grey / silvermaterial ABSweight 1000 gdimensions (H x W x D) 170 mm x 170 mm x 55 mm
art. 31674
www.detectomat.com
82
7. home smoke detectors
radio link module FM 868
bidirectional radio module to interlink home detectors in cascadednetworks in the transmitting frequency of 868MHz
• working area in frequency band 868 MHz• bidirectional controlling function in case of alarm, signalising of
all connected detectors
• with the module the detectors can be cascade interlinked without a panel
• automatic amplifying of the radio signal via the integrated repeater function
technical specification
alarm current 37 mAinterfaces radio link interface to the
home detectoroperation temperature -10°C bis +60°Chumidity 95 % RH / 40°Cweight 100 g
art. 30933
radio link module FM 433
wireless module to connect home detectors to the wireless fire control panel RCP6 in the transmitting frequency of 433 MHz
• working area in frequency band 433 MHz
• with the module the home smoke detectors can be connected tothe fire control panel RCP6
technical specification
alarm current 37 mAinterfaces radio link interface to the
home detectoroperation temperature -10°C up to +60°Chumidity 95 % RH / 40°Cweight 100 g
art. 30947
www.detectomat.com
83
8.1 signalling devices for loop3000
8. signalling devices
loop sounder, red LS 3300 R
low current multiple tone sounder directly powered by the loop3000, red
• direct addressable via the loop3000 • integrated bidirectional short circuit isolator• addressable spur connection via T-branch
• 2 different tones adjustable (including DIN tone)• automatic addressing (soft-addressing)• manual addressing (EasyCheck)
technical specification
operation voltage 15 up to 30 V loop poweredalarm current 5 mAnoise max. 97 dBoperation temperature -10°C up to +60°Cprotection class IP 43housing colour redmaterial ABSweight 340 gdimensions (H x Ø) 100 mm x 101 mm
art. 31836
loop sounder, white LS 3300 W
low current multiple tone sounder directly powered by the loop3000, white
• direct addressable via the loop3000 • integrated bidirectional short circuit isolator• addressable spur connection via T-branch
• 2 different tones adjustable (including DIN tone)• automatic addressing (soft-addressing)• manual addressing (EasyCheck)
technical specification
operation voltage 15 up to 30 V loop poweredalarm current 5 mAnoise max. 97 dBoperation temperature -10°C up to +60°Cprotection class IP 43housing colour whitematerial ABSweight 340 gdimensions (H x Ø) 100 mm x 101 mm
art. 32012
loopsounder kit LS 3300 VLC
low current multiple tone sounder directly powered by the loop3000 via control modul, white
• direct addressable via the loop3000• multiple tone sounder with 32 different tones
(including DIN tone) adjustable via DIP button • tones in the frequency-band of 440 Hz up to 2900 Hz are
synchronizable• 3 sound levels adjustable
• shallow base for lateral and rear cable entry
technical specification
frequency 440 up to 2900 Hzoperation voltage 15 up to 30 V loop poweredalarm current 5 mAnoise max. 97 dBoperation temperature -10°C up to +60°Cprotection class IP 43housing colour whitematerial ABSweight 250 gdimensions (H x Ø) 27 mm x 117 mmcomplies with EN 54
art. 32060
www.detectomat.com
84
8.1 signalling devices for loop3000
8. signalling devices
loopsounder base kit LS 3300 SBK
low current multiple tone sounder directly powered by the loop3000via control modul, integreated base for addressable detectors of the series loop3000, white
• direct addressable via the loop3000• including detector base for all
detectors of the series loop3000 • multiple tone sounder with 32 different
tones (including DIN tone) adjustable via DIP button • tones in the frequency-band of 440 Hz up to 2900 Hz are
synchronizable• 3 sound levels adjustable• shallow base for lateral and rear cable entry
• detector not included
technical specification
frequency 440 up to 2900 Hzoperation voltage 15 up to 30 V loop poweredalarm current 5 mAnoise max. 97 dBoperation temperature -10°C up to +60°Cprotection class IP 43housing colour whitematerial ABSweight 250 gdimensions (H x Ø) 45 mm x 117 mmcomplies with EN 54
art. 32061
sound unit SDM 3300 R
sounder to use in the loop3000,low powered multiple-tone sounder with sound-module, according to DIN 33404 addressable connection with external voltage
• direct connection to the loop3000 • integrated automatic addressing-unit• integrated bidirectional short circuit isolator• addressable spur connection via T-branch• external voltage supply 24 V necessary• internal sound levels adjustable
• shallow base for lateral and rear cable entry
technical specification
frequency 500 up to2850 Hzoperation voltage 15 up to 30 Vquiesent current 250 µAalarm current 9 up to 29 mAnoise 111 dBoperation temperature -10°C up to +60°Cprotection class IP 54housing colour redmaterial ABSweight 340 gdimensions (H x Ø) 93 mm x 93 mmcomplies with EN 54
art. 30204
cover for sounder, color red AD Rart. 32067
cover for sounder, color white AD Wart. 32068
loop beacon, red LB-3300-VXB-R
low current beacon unit directly powered by the loop3000 via control modul
• low current beacon• white housing with red light cover• brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt
technical specification
frequency 1 Hzoperation voltage 15 up to 30 V loop poweredalarm current 5 mAoperation temperature -10°C up to +60°Cprotection class IP 43housing colour whitematerial ABSweight 145 gdimensions (H x Ø) 60 mm x 95 mm complies with EN 54
art. 32058
www.detectomat.com
85
8.1 signalling devices for loop3000
8. signalling devices
8.2 conventional signalling devices
multiple tone sounder, red VTG-32-SB R
low powered multiple-tone sounder,colour: red, modern technology with 32 different tones
• multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button
• tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable
• 3 sound levels adjustable
• shallow base for lateral and rear cable entry
technical specification
frequency 440 up to 2900 Hzoperation voltage 15 up to 35 V DCalarm current 9 up to 36 mAnoise max. 111 dBoperation temperature -20°C up to +70°Cprotection class IP 43housing colour redmaterial ABSweight 220 gdimensions (H x Ø) 85 mm x 94 mmapprovals VdS G 205137complies with EN 54
art. 32051
multiple tone sounder, white VTG-32-SB W
low powered multiple-tone sounder,colour: white, modern technology with 32 different tones
• multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button
• tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable
• 3 sound levels adjustable
• shallow base for lateral and rear cable entry
technical specification
frequency 440 up to 2900 Hzoperation voltage 15 up to 35 V DCalarm current 9 up to 36 mAnoise max. 111 dBoperation temperature -20°C up to +70°Cprotection class IP 43housing colour whitematerial ABSweight 220 gdimensions (H x Ø) 85 mm x 94 mmapprovals VdS G 205137complies with EN 54
art. 32053
loop beacon, orange LB 3300 VXB O
low current beacon unit directly powered by the loop3000 via control modul
• low current beacon• white housing with orange light cover• brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt
technical specification
frequency 1 Hzoperation voltage 15 up to 30 V loop poweredalarm current 5 mAoperation temperature -10°C up to +60°Cprotection class IP 43housing colour whitematerial ABSweight 145 gdimensions (H x Ø) 60 mm x 95 mm complies with EN 54
art. 32090
base sounder Verso 32 Tone
low powered multiple-tone sounder,colour: white, modern technology with 32 different tone
• multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button
• tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable
• 3 sound levels adjustable
• shallow base for lateral and rear cable entry
technical specification
frequency 440 up to 2900 Hzoperation voltage 15 up to 35 V DCalarm current 9 up to 36 mAnoise max. 111 dBoperation temperature -20°C up to +70°Cprotection class IP 43housing colour whitematerial ABSweight 250 gdimensions (H x Ø) 27 mm x 117 mmcomplies with EN 54
art. 32055
8.2 conventional signalling devices
8. signalling devices
multiple tone sounder, red, IP 65 VTG-32-DB R
low powered multiple-tone soundercolour: red, modern technology with 32 different tones, class of protection: IP 65
• multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button
• tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable
• 3 sound levels adjustable
• shallow base for lateral and rear cable entry
technical specification
frequency 440 up to 2900 Hzoperation voltage 15 up to 35 V DCalarm current 9 up to 36 mAnoise max. 111 dBoperation temperature -20°C up to +70°Cprotection class IP 65housing colour redmaterial ABSweight 250 gdimensions (H x Ø) 102 mm x 94 mmapprovals VdS G 205137complies with EN 54
art. 32052
multiple tone sounder, white, IP 65 VTG-32-DB W
low powered multiple-tone soundercolour: white, modern technology with 32 different tones, class of protection: IP 65
• multiple tone sounder with 32 different tones(including DIN tone) adjustable via DIP button
• tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable
• 3 sound levels adjustable
• shallow base for lateral and rear cable entry
technical specification
frequency 440 up to 2900 Hzoperation voltage 15 up to 35 V DCalarm current 9 up to 36 mAnoise max. 111 dBoperation temperature -20°C up to +70°Cprotection class IP 65housing colour whitematerial ABSweight 250 gdimensions (H x Ø) 102 mm x 94 mmapprovals VdS G 205137complies with EN 54
art. 32054
www.detectomat.com
86
8.2 conventional signalling devices
8. signalling devices
www.detectomat.com
87
symphony tone sounder SYS 120 R
multiple-tone sounder,colour: red, modern technology with 32 different tones
• multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button
• tones in the frequency-band of 500 Hz up to 2850 Hz are synchronizable
• 3 sound levels adjustable• strong sound with up to 120 dB
technical specification
frequency 500 up to 2850 Hzoperation voltage 9 up to 28 V DCalarm current 230 up to 290 mAnoise max. 120 dBoperation temperature -25°C up to +55°Cprotection class IP 43housing colour redweight 340 gdimensions (H x W x D) 106 mm x 106 mm x 95 mmapprovals VdS G 206026complies with EN 54
art. 30216
voice sounder CLA R
sounder with voice-announcement,high voice quality, standard announcement stored
• sounder with voice announcement• multifunction alarm sounder• adjustable volume• base is compatible to sounders and beacons• high quality of the sound rendition• standard announcements are stored in the database• automatic synchronization • low current consumption
technical specification
input voltage 18 up to 30 V DCoperation voltage 18 up to 30 V DCalarm current 20 mAnoise 102 dBoperation temperature -10°C up to +55°Cprotection class IP 65housing colour redweight 265 gdimensions (H x Ø) 83 mm x 95 mmcomplies with EN 54
art. 31664
voice sounde CLA W
sounder with voice-announcement,high voice quality, standard announcement stored
• sounder with voice announcement• multifunction alarm sounder• adjustable volume• base is compatible to sounders and beacons• high quality of the sound rendition• standard announcements are stored in the database• automatic synchronization • low current consumption
technical specification
input voltage 18 up to 30 V DCoperation voltage 18 up to 30 V DCalarm current 20 mAnoise 102 dBoperation temperature -10°C up to +55°Cprotection class IP 65housing colour whiteweight 265 gdimensions (H x Ø) 83 mm x 95 mmapprovals pendingcomplies with EN 54
art. 31665
cover for sounder, color red AD Rart. 32067
cover for sounder, color white AD Wart. 32068
8.2 conventional signalling devices
8. signalling devices
LED indicator PA
LED indicator for alarm display of the automatic detectors series loop3000 and CT
• alarm indicator for flush mounted detectors• connection to the detector base• on-wall mounting
technical specification
alarm current 4 mAhousing colour whitematerial ABSdimensions (H x W x D) 84 mm x 84 mm x 35 mm
art. 31193
LED indicator PA2-VdS
LED indicator for alarm display of the automatic detectors series loop3000 and CT
• alarm indicator for flush mounted detectors
• connection to the detector base• on-wall mounting
technical specification
alarm current 2,5 mAhousing colour whitematerial ABSdimensions (H x W x D) 86 mm x 86 mm x 45 mmapprovals VdS G 294052
art. 31195
LED indicator, flush-mounting PA-uP
LED indicator for alarm display of the automatic detectors series loop3000 and CT
• alarm indicator for flush mounted detectors• connection to the detector base• flush mounting, installation hole 22 mm diameter
technical specification
alarm current 3 mAhousing colour whitematerial ABSdimensions (H x Ø) 52 mm x 26 mm
art. 30178
beacon, red BE 24
conventional beacon unit, red
• available in the colours red, orange, green and blue• brightness 2 joule at 24 V and 1 joule at 12 V• IP rating 65 will be achieved with base 40059 red or 40060 white
technical specification
frequency 1 Hzoperation voltage 12 / 24 V DCalarm current 155 mAoperation temperature -10°C up to +60°Cprotection class IP 54, with additional base IP 65material ABSdimensions (H x Ø) 72 mm x 93 mmapprovals VdS G 296014
remarks: when ordering please indicate the color and the operationvoltage of the calotte
art. 40100
www.detectomat.com
88
www.detectomat.com
89
8.2 conventional signalling devices
8. signalling devices
round beacon RBE 24
conventional round beacon unit, red
• available in the colours red and orange• brightness 5 joule at 24 V
technical specification
frequency 1 Hzoperation voltage 24 V DCalarm current 200 mAoperation temperature -10°C up to +60°Cprotection class IP 54housing colour whitematerial ABSdimensions (H x Ø) 135 mm x 108 mm
remarks: when ordering please indicate the color of the calotte
art. 30228
beacon, red VXB-1-SB-WB-RL
low current beacon unit, red housing, red light
• low current beacon• available in the colours red and orange
• brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt
technical specification
frequency 1 Hzoperation voltage 20 up to 35 Valarm current 3 up to 5 mAoperation temperature -20°C up to +70°Cprotection class IP 43housing colour whitematerial ABSweight 145 gdimensions (H x Ø) 60 mm x 95 mm
remarks: when ordering please indicate the color of the calotte
art. 32056
beacon IP 65 VXB-1-DB-WB-RL
low current beacon unit, white housing, red light, IP 65
• low current beacon• available in the colours red and orange
• brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt
technical specification
frequency 1 Hzoperation voltage 20 up to 35 Valarm current 3 up to 5 mAoperation temperature -20°C up to +70°Cprotection class IP 65housing colour whitematerial ABSweight 165 gdimensions (H x Ø) 80 mm x 95 mm
remarks: when ordering please indicate the color of the calotte
art. 32057
8.2 conventional signalling devices
8. signalling devices
sounder beacon combination, white VTB-32-SB W
low powered multiple-tone sounder with 32 different tones,colour: white, combined with beacon red
• multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button
• tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable
• 3 sound levels adjustable• brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt
technical specification
frequency 440 up to 2900 Hzoperation voltage 15 up to 35 V DCalarm current 14 up to 41 mAnoise max. 109 dBoperation temperature -20°C up to +70°Cprotection class IP 43housing colour whitematerial ABSweight 233 gdimensions (H x Ø) 90 mm x 94 mm
art. 32062
sounder beacon combination, white, IP 65 VTB-32-DB W
low powered multiple-tone sounder with 32 different tones,colour: white, combined with beacon red, IP 65
• multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button
• tones in the frequency-band of 440 Hz up to 2900 Hz aresynchronizable
• 3 sound levels adjustable• brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt
technical specification
frequency 440 up to 2900 Hzoperation voltage 15 up to 35 V DCalarm current 14 up to 41 mAnoise max. 109 dBoperation temperature -20°C up to +70°Cprotection class IP 65housing colour whitematerial ABSweight 258 gdimensions (H x Ø) 107 mm x 94 mm
art. 32063
www.detectomat.com
90
www.detectomat.com
91
9. door magnets and accessoires
power supply 450 mA SV 04
power supply 450 mA for door magnets
• integreated short circuit protection
• LED indicator for operation display
technical specification
input voltage 230 V ACfrequency 50 Hz +/- 10 %operation voltage 24 V DCexternal user output 400mAoperation temperature -10 up to +40°Cprotection class IP 20housing colour silvermaterial sheet steel dimensions (H x W x D) 115 mm x 80 mm x 50 mmapprovals DIBT Z6.5-1335, VdS approved
art. 30411
power supply 800 mA SV 08
power supply 800 mA for door magnets
• integreated short circuit protection
• LED indicator for operation display
technical specification
input voltage 230 V ACfrequency 50 Hz +/- 10 %operation voltage 24 V DCexternal user output max 800mAoperation temperature -10 up to +40°Cprotection class IP 20housing colour whitematerial sheet steeldimensions (H x W x D) 160 mm x 105 mm x 55 mmapprovals DIBT Z6.5-1335, VdS approved
art. 30412
door control panel TSZ 0400
microprcessor controlled panel to control fire doors, door magnets and detectors
• integreated power supply for detectors and door magnets• alarm evaluation and controlling functions• integreated reset function• additional external output for connection of signalling devices
• up to 3 panels linkable• integreated short circuit protection• LED indicators for operation, alarm and fault display• up to 10 detectors connectable• up to 12 door magnets connectable• usable in ex-areas with accessoires
technical specification
input voltage 230 V ACfrequency 50 Hz +/- 10 %operation voltage 24 V DCrelay output 2 change over 30V / 1Aexternal user output max 800mAoperation temperature 0 up to +40°Cprotection class IP 42housing colour greywhite, RAL 9002material ABSdimensions (H x W x D) 185 mm x 233 mm x 93 mmapprovals DIBT Z6.5 - 1646, VdS approved
art. 30410
www.detectomat.com
9. door magnets and accessoires
optical detector with relay base RM3000
conventional optical smoke detector, complies with EN 54 part 7specification and relay base for connection on door control panels
• integreated relay base• 3 times alarm evaluation for controlling function• LED indicator for operation, alarm and fault display
technical specification
operation voltage 18 up to 28 V DCquiesent current 24 mAalarm current 62 mArelay output 1 change over 50V / 1Aoperation temperature -20°C up to +60°Cprotection class IP 43housing colour whitematerial ABSdimensions (H x Ø) 50 mm x 100 mmapprovals DIBT Z6.5-1335, VdS G 200 107
art. 31236
manual activation button HT uP
for door control units with flush-mounting
technical specification
operation temperature -20°C up to +60°Chousing colour redmaterial ABSdimensions (H x W x D) 80 mm x 80 mm x 33 mm
art. 30418
manual activation button HT aP
for door control units with on-wall mounting
technical specification
operation temperature -20°C up to +60°Chousing colour redmaterial ABSdimensions (H x W x D) 63 mm x 63 mm x 37 mm
art. 30417
92
www.detectomat.com
9. door magnets and accessoires
93
door magnet EM GD 60 S 175
panning-head magnet with turnable head to mount at walls, ceilings or floors
• integrated activation button
• input protection via diode• polarisation protected• peel adhesion 700N• power on time 100%• magnet diameter 60mm• length 175mm, 90° deviated 137 mm
technical specification
operation voltage 24 V DC ± 10 %alarm current 67 mAoperation temperature -20°C up to +60°Cprotection class IP 40colour greymaterial steeldimensions (H x Ø) 175 mm x 96 mm approvals DIBT Z.6.5-1335, VdS approved
art. 30423
door magnet EM GD 60 K 70
door magnet for wall mounting with plastic-bottom, for door holding
• integrated activation button
• input protection via diode• polarisation protected• peel adhesion 700N• power on time 100%• magnet diameter 60 mm
technical specification
operation voltage 24 V DC ± 10 % alarm current 67 mAoperation temperature -20°C up to +60°Cprotection class IP 40colour greymaterial steel/ABSdimensions (H x Ø) 70 mm x 82 mm approvals DIBT Z.6.5-1335, VdS approved
art. 30422
door magnet EM GD 60 F 26
door magnet for wall mounting, for door holding
• integrated activation button
• input protection via diode• polarisation protected• peel adhesion 700N• power on time 100%• magnet diameter 60 mm
technical specification
operation voltage 24 V DC ± 10 %alarm current 67 mAoperation temperature -20°C up to +60°Cprotection class IP 40colour greymaterial steeldimensions (H x W x D) 30 mm x 55 mm x 93 mmapprovals DIBT Z6.5 1335, VdS approved
art. 30428
www.detectomat.com
9. door magnets and accessoires
94
door magnet EM GD 60 S 475
panning-head magnet with turnable head to mount at walls, ceilingsor floors
• integrated activation button• input protection via diode• polarisation protected
• peel adhesion 700N• power on time 100%• magnet diameter 60 mm• length 475mm, 90° deviated 437 mm
technical specification
operation voltage 24 V DC ± 10 % alarm current 67 mAoperation temperature -20 up to +60°Cprotection class IP 40colour light greymaterial steeldimensions (H x Ø) 475 mm x 96 mm approvals DIBT Z.6.5-1335, VdS approved
art. 30425
door magnet EM GD 60 FB
door magnet with a robust housing of aluminium for base-mounting
• integrated activation button• input protection via diode• polarisation protected• peel adhesion 700N• power on time 100%
technical specification
operation voltage 24 V DC ± 10 % alarm current 67mAoperation temperature -20 up to +60°Cprotection class IP 40colour blackmaterial aluminiumdimensions (H x W x D) 100 mm x 165 mm x 107 mmapprovals DIBT Z.6.5-1335, VdS approved
art. 30434
door magnet EM GD 60 S 325
panning-head magnet with turnable head to mount at walls, ceilings or floors
• integrated activation button• input protection via diode• polarisation protected
• peel adhesion 700N• power on time 100%• magnet diameter 60 mm• length 325mm, 90° deviated 287 mm
technical specification
operation voltage 24 V DC ± 10 % alarm current 67 mAoperation temperature -20 up to +60°Cprotection class IP 40colour light greymaterial steeldimensions (H x Ø) 325 mm x 96 mm approvals DIBT Z.6.5-1335, VdS approved
art. 30424
www.detectomat.com
9. door magnets and accessoires
95
anchor plate AP GD 60 W 50
flexible anchor plate with rubber bearing and angle joint usable forthe connection between door magnet and fire door
• up to 60° movable• zinc housing• plate diameter 64 mm
technical specification
colour blackmaterial steeldimensions (H x W x D) 65 mm x 65 mm x 51 mm
art. 30438
anchor plate AP GD 60 T 80
telescope anchor plate with damper usable for the connectionbetween door magnet and fire door
• for heavy doors and gates• robust black housing• flexible anchor plate diameter 64 mm• elasticity strength approximately 100 N at 20 mm lift
technical specification
colour blackmaterial steeldimensions (H x Ø) 85 mm x 80 mm
art. 30439
anchor plate AP GD 60 G 16
flexible anchor plate with rubber bearing usable for the connectionbetween door magnet and fire door
• up to 10° movable• zinc housing• plate diameter 64 mm
technical specification
colour zincmaterial steeldimensions (H x W x D) 65 mm x 65 mm x 16 mm
art. 30437
door magnet EM GD 70 Ex
ex-proof door magnet usable in ex areas with protection class zone 1 and 2
• ex proof housing• connectable via
terminal blocks• input protection via diode• polarisation protected• peel adhesion 1450N• power on time 100%
technical specification
operation voltage 24 V DC alarm current 70mAoperation temperature -20°C up to +40°Cprotection class IP 66colour greymaterial steeldimensions (H x W x D) 110 mm x 75 mm x 43 mmapprovals DIBT Z-6.5-1335,
Ex II 2G Eex m II T6, IP 66complies with Ex II 2G EExem II T6intriscally safe class Eex m/e IIT6
art. 30436
www.detectomat.com
10. detector testing devices
96
aerosol smoke dispenser SOLO 330
smoke dispenser for the release of smoke test aerosol for efficientactivation of detectors
• clear cup - allows view of detector LED• spring loaded mechanism for effectiv, economic aerosol delivery • touch sensitiv - ideal for suspended ceilings
art. 14008
heat detector tester SOLO 461
wire free test set for heat detectors including:
• cordless heat detector tester• 2 battery batons• 1 fast charger
art. 30398
smoke detector test & removal set SOLO 812
kit includes the following:
• 1 fibreglass telescopic extension pole 4,50 metres• 1 fibreglass extension pole 1,13 metres• 1 universal removal tool• 1 aerosol smoke dispenser• 1 protective carrying / storage bag
art. 31956
detector removal tool SOLO 200
detector removal tool for easy replacement of all detectors
art. 14007
www.detectomat.com
10. detector testing devices
97
telescope pole SOLO 100
telescope pole, expandable in 4 sections
• 4 section fibreglass telecope pole expandable from 1,20m up to 4,50m
art. 14006
bag for test-set SOLO 610
carrying / storage bag for test equipment
• designed to fit all test equipment• separate pole bag included
technical specification
dimensions (H x W x D) 460 mm x 45 mm x 180 mm
art. 14010
extension pole SOLO 101
fibreglass extension pole 1,13 metres • maximum applicable 2 pieces each telescope bar
art. 30193
testaerosol TA 300
for smoke detectors, 300 ml
art. 40055
testaerosol SOLO A3
for smoke detectors, 250 ml
art. 31845
www.detectomat.com
Article index
98
art. Typ Description page14006 telescope pole SOLO 100 97
14007 detector removal tool SOLO 200 96 14008 aerosol smoke dispenser SOLO 330 96 14010 bag for test-set SOLO 610 9730003 wireless optical smoke detector WL 3200 O 59 30007 optical smoke and heat detector PL 3200 OT 38 30008 heat detector PL 3200 T 37 30009 optical smoke detector PL 3200 O 33 30010 heat detector, isolator PL 3300 T 37 30011 optical smoke detector, isolator PL 3300 O 33 30014 heat detector CT 3000 T 42 30015 optical smoke detector CT 3000 O 39 30021 optical smoke and heat detector, isolator PL 3300 OT 38 30022 multisensor detector CT 3000 OT 42 30023 optical home detector HD 3001 O white 79 30024 optical home detector HD 3001 O silver 80 30025 WGW 3300 wireless gateway 59 30026 WGW 3300 HFM EG-Gx 55 30077 Relay board 8 change over RL 58 18 30078 aspiration smoke detector ASD-20 65 30079 CO gas and heat detector, isolator PL 3300 CDBT 39 30087 bitbus interface CP BBI 26 30088 LED indicator modul CP ZM 8 9, 10 30092 optical smoke detector, isolator PL 3300 O/K 36 30096 conventional interface redundant 8 fire zones CP CLI X2-R 15 30097 extension module CP ECB 15 30098 LED indicator modul CP ZM 32 15, 16 30099 mount in printer including paper storage PIP 1 10, 16, 20 30106 mount in printer PIP 2 4, 10, 12, 16, 20 30111 Extinguishing control modul CP ETB X1 10 30112 Redundant main board processor CP CPU X2-R 17 30113 Redundant main board processor CP CPU X1-R 11 30114 extinguishing interface CP SIE 19 30115 OC control module CP AM 32 19 30116 connection board CP AM AP 19 30118 monitored module for 8 outputs SC 8 18 30119 bitbus CPU BB-CPU 26 30120 extension for BitBus CPU, 32 open collector outputs BB-32 26 30122 extension for BitBus CPU, 16 relay outputs BB-16 26, 27 30123 optical home detector HD 3001 O black 80 30124 BitBus amplifier BB-R 27 30128 BitBus LED indicator extension BB-LED 27 30131 power supply 192 W NT 8 21 30136 detectomat programming tool DPT 3000 29 30137 software-expansion-dongle D 3000 29 30138 modem RM MO 23 30139 Bitbus programming tool BPT 26, 29 30143 Visual detect basis software VD Basic 11 31 30144 Visual detect user expansion VD UE 1 32 30145 Visual detect expansion panel VD PE 1 32 30146 Visual detect operation expansion VD CE 1 32 30151 battery 12 V / 45 Ah B 12/ 45Ah 22 30155 battery 12 V / 12 Ah B 12/ 12Ah 21 30156 battery 12 V / 18 Ah B 12/ 18Ah 22 30164 mounting plate MP 16 30167 19" front panel 64 19" FP-1 16 30168 19" front panel 128 19" FP-2 16 30169 19" front panel 192 19" FP-3 16 30178 LED indicator, flush-mounting PA-uP 88 30187 detector mounting adapter MKBD 47 30188 detector flap-mounting adapter MKK 47 30189 detector distance-mounting adapter MAK 48 30190 wall bracket WA4 48 30191 wall bracket WA2 48 30193 extension pole SOLO 101 97 30200 in-/output module IOM 3311 56 30201 2-loop interface redundant DLI 3240 X2-R 14 30204 sound unit SDM 3300 R 84 30205 conventional zone module TCM 3300 58 30209 2-loop interface DLI 3240 X1-2L 7 30210 conventional interface for 8 fire zones CP CLI X1 9
www.detectomat.com
Article index
99
art. Typ Description page30211 output module OMS 3301 57 30216 SYS 120 R symphony tone sounder 87 30217 ex multiple tone sounder DB 5 77 30218 housing for ex-modules M-1 78 30219 ex-barrier SB SE/24 Ex 77 30228 round beacon RBE 24 89 30301 detector base SDB 3000 43 30321 base for overvoltage protection modules CT B 22 30335 Loop protection module CT ME 48 23 30336 Conventional protection module CT ME / C 24 23 30337 Bitbus protection module CT ME 5 23 30386 Adapter for LED indicator modul CP ADB 48 9, 10 30398 heat detector tester SOLO 461 96 30410 door control panel TSZ0400 91 30411 power supply 450 mA SV 04 91 30412 power supply 800 mA SV 08 91 30417 manual activation button HT aP 92 30418 manual activation button HT uP 92 30422 door magnet EM GD 60 K 70 93 30423 door magnet EM GD 60 S 175 93 30424 door magnet EM GD 60 S 325 94 30425 door magnet EM GD 60 S 475 94 30428 door magnet EM GD 60 F 26 93 30434 door magnet EM GD 60 FB 94 30436 door magnet EM GD 70 Ex 95 30437 anchor plate AP GD 60 G 16 95 30438 anchor plate AP GD 60 W 50 95 30439 anchor plate AP GD 60 T 80 95 30458 optical home detector HDv 3000 O 79 30461 battery 12 V / 65 Ah B 12/ 65Ah 22 30469 detector relay base DRB 3000 44 30471 power supply 120 W NT 5 21 30473 infrared beam detector SPB-E IR BD 70 30474 infrared beam detector SRA-ET IR BD-R 71 30477 ultraviolet flame detector X 2200 74 30479 labelling tag for detector base MBC 47 30488 optical smoke detector, isolator, silver PL 3301 O silver 34 30501 I-Check 3000 software I-Check 3000 29 30503 sensor cable detector SKM-03.01 72 30513 mini in-/output module AMD 3311 57 30523 detector base, black SDB 3000 black 43 30525 optical smoke detector, isolator, black PL 3301 O black 34 30545 optical smoke detector, white CT 3004 O white 42 30546 optical smoke detector, silver CT 3004 O silver 41 30551 optical smoke detector, white CT 3005 O white 41 30552 optical smoke detector, silver CT 3005 O silver 41 30555 optical smoke detector, isolator, white PL 3304 O white 34 30556 optical smoke detector, isolator, silver PL 3304 O silver 35 30567 optical smoke detector, isolator, white PL 3305 O white 35 30568 optical smoke detector, isolator, silver PL 3305 O silver 35 30569 manual call point, chinese PL 3300 MCP-kit 53 30926 detector base, silver SDB 3000 silver 43 30927 ground circuit module CP EM 9 30933 radio link module FM 868 82 30941 conventional fire control panel BMZ 6 32 30947 radio link module FM 433 82 30956 optical smoke detector, isolator, white PL 3301 O white 34 30977 optical smoke detector CT 3000 O/K 40 30980 sensor cable red SKM-KRT 72 30981 sensor cable black SKM-KSW 72 31024 BitBus computer interface ISA-Slot BBI PC 28 31059 manual call point, ABS PL 3300 PBD-ABS-B 49 31060 manual call point, ABS PL 3300 PBD-ABS-Y 50 31061 manual call point, ALU PL 3300 PBD- ALU-B 51 31062 manual call point, ALU PL 3300 PBD-ALU-Y 51 31069 glass for manual call point HFM EG-B 55 31083 manual call point, IP 66 CT 3000 PDB-IP66-R 54 31087 manual call point, ALU, blue CT 3000 PBD-ALU-BD 53 31088 manual call point, ALU, yellow CT 3000 PBD-ALU-YD 54 31091 weatherproof housing WG-R 55 31092 weatherproof housing WG-B 55
www.detectomat.com
Article index
100
art. Typ Description page31095 infrared beam detector FR 2000 70 31096 reset module RM95 70 31114 Stratos HSSD-2 standard detector HSSD-2 M 62 31115 Stratos HSSD-2 standard detector and control module HSSD-2 M-S 63 31117 Stratos HSSD-2 control module HSSD-2 S 63 31118 Stratos Micra 25 including mounting base Micra 25 64 31133 Stratos asirating pipe 3/4" STR-R 65 31135 Stratos 45° deg elbow pipe STR-W45 66 31136 Stratos 90° bend STR-B90 66 31138 Stratos socket STR-M 66 31140 Stratos T-piece STR-T 66 31141 Stratos socket union STR-V 66 31143 Stratos end cap STR-E 66 31145 Stratos pipe clip, red STR-C 69 31146 Stratos pipe clip black STR-CA 69 31147 Stratos ABS solvent cement STR-SK 69 31148 Stratos pipe cleaner STR-RE 69 31149 Stratos sampling hole warning stickers STR-WA 69 31151 Stratos nylon tube, red STR-KR 68 31152 Stratos nylon tube, white STR-KW 69 31153 Stratos in-line remote sampling point adapter STR-MK 68 31154 Stratos end cap adaptor STR-EK 68 31155 Stratos in-line smapling point STR-KK 68 31156 Stratos patress sampling point STR-KB 68 31163 ex-ionisation smoke detector IRM Ex S60 75 31164 ex-heat detector WM Ex S60 76 31169 base for ex-detector Meldersockel Ex 76 31170 ex manual call point HFM S65, Ex 77 31174 ex-barrier Ex-B1 76 31181 base for humid areas FRS 45 31191 housing for air ducts LKMG 45 31193 LED indicator PA 88 31195 LED indicator PA2-VdS 88 31222 ex-beacon, red BE 24 R EEx 78 31223 ex-beacon, yellow BE 24 Y EEx 78 31236 optical detector with relay base RM3000 92 31312 2-loop interface redundant DLI 3240 X1-R 8 31315 LCD repeater panel LCD-Tableau 25 31318 universal expansion housing UZG-1 11 31320 universal expansion housing UZG-2 17 31476 Stratos Micra 100 including mounting base Micra 100 64 31482 EasyCheck EC 3000 7, 8, 14, 30 31486 infrared beam detector FR 100 RV 71 31589 optical smoke detector, silver CT 3001 O silver 40 31596 parallel indicator display ZPA2002 20 31613 Stratos plug sampling point assembly STR-SK 67 31620 fanstening clamp SK-LS 72 31621 BitBus - fibre optical interface LCON-1 28 31622 fibre optical cable converter LCON-2 28 31625 loop tester LT 3000 30 31626 radio field analyzer RFA 3000 61 31627 wireless input module WL 3210 EM 60 31640 mini output module OMS 3301mini 57 31651 manual call point, ABS, blue CT 3000 PBD-ABS-B 53 31654 Visual detect interface management system VD M I 32 31664 voice sounder CLA R 87 31665 voice sounder CLA W 87 31668 manual call point, ALU PL 3300 PBD-ALU-R 50 31669 manual call point, ABS PL 3300 PBDH-ABS-R 49 31674 wireless fire control panel RCP 6 82 31675 manual call point, ABS, red CT 3000 PBDH-ABS-R 52 31676 manual call point, ALU, red CT 3000 PBDH-ALU-R 53 31684 flush-mounting adapter silver DR45 41, 46 31698 wall mount base adapter APS 45 31817 1-loop interface DLI 3240 X1-1L 7 31836 loop sounder, red LS 3300 R 83 31837 optical home detector HD 3004 O white 80 31845 testaerosol SOLO A3 97 31861 infrared beam detector FR 50 RV 71 31867 Stratos HSSD-2 standard detector without display HSSD-2 MOD 62 31875 base with heating APSB 46
www.detectomat.com
Article index
101
art. Typ Description page31896 ultraviolet flame detector FL 800/24V-K-N 73 31897 ultraviolet flame detector FL 80/1A 73 31910 glass for manual call point HFM EG 55 31911 demo software for visual detect VD DV 31 31914 optical home detector HD 3004 O silver 81 31926 optical smoke detector, black CT 3001 O black 40 31929 optical smoke detector, white CT 3001 O white 40 31946 mounting plate CP MP 3004 10 31947 mounting plate CP MP 3016 16 31948 Stratos adapter 3/4" female to 25 mm male STR-R3/4"-25 67 31949 Stratos 25 mm female to 3/4" male adapter STR-R26-3/4" 67 31950 Stratos socket 3/4" to 25 mm female STR-RM5 67 31953 Stratos HSSD-2 control module 19" HSSD-2 S 19" 63 31956 smoke detector test kit SOLO 812 96 31959 detector base, bridged SDBB 3000 43 31960 Stratos flange nut STR-CM 69 31972 fire control panel shallow detect 3004 - shallow 5 31973 fire control panel detect 3004 4 31974 language kit German LK 3004 D 6 31975 language kit English LK 3004 GB 6 31989 fire control panel detect 3016 12 31990 fire control panel 19" rack mount detect 3016-19" 13 31991 language kit German LK 3016 D 13 31992 language kit English LK 3016 GB 13 32004 optical home detector HD 3005 O silver 81 32005 antenna for extended range WGA 3200 6032012 loop sounder, white LS 3300 W 83 32015 optical home detector HD 3005 O white 81 32039 language kit German for a master panel in the BitBus network LK ABF D 24 32040 language kit English for a master panel in the BitBus network LK ABF GB 24 32045 optical smoke detector PL 3200 O/K 36 32049 fire control panel 19" rack mount detect 3004-19" 6 32050 Stratos ABS-socket 3/4" to 25 mm STR-RH 67 32051 multiple tone sounder, red VTG-32-SB R 85 32052 multiple tone sounder, red, IP 65 VTG-32-DB R 86 32053 multiple tone sounder, white VTG-32-SB W 85 32054 multiple tone sounder, white, IP 65 VTG-32-DB W 86 32055 base sounder Verso 32 Tone 86 32056 beacon VXB-1-SB-WB-RL 89 32057 beacon IP 65 VXB-1-DB-WB-RL 89 32058 loop beacon, red LB-3300-VXB-R 84 32060 loopsounder kit LS 3300 VLC 83 32061 loopsounder base kit LS 3300 SBK 84 32062 sounder beacon combination, white VTB-32-SB W 90 32063 sounder beacon combination, white, IP 65 VTB-32-DB W 90 32066 monitored module for 4 outputs SC 4 18 32067 cover for base sounder AD R 84, 87 32068 cover for base sounder AD W 84, 87 32070 flush-mounting adapter white DR45W 46 32073 extension module UBW 3311 56 32074 in-/output module mini AOM 3301 58 32075 infrared flame detector X 9800 74 32076 aspiration smoke detector ASD-01 65 32077 ultraviolet/infrared flame detector Eye 20/20 L 75 32082 manual call point, ABS, red SBDH-ABS-R 54 32083 detector base, bridged SDBB 3000 black 43 32084 detector base, bridged SDBB 3000 silver 43 32085 detector relay base DRB 3000 black 44 32086 detector relay base DRB 3000 silver 44 32090 loop beacon, orange LB 3300 VXB O 85 32091 piezo buzzer for detectors Sockel Piezo 44 32098 2-loop interface active DLI 3240 P X1 8 32099 2-loop interface active, redundant DLI 3240 P X2-R 14 32118 remote display- and control panel ABF 24 32119 remote display- and control panel ABF 19" 2540001 battery 12 V / 26 Ah B 12/ 26Ah 22 40003 Extinguishing control modu CP ETB X2l 17 40054 key for manual call point HFM-SCH-M 55 40055 testaerosol TA300 97 40056 battery 12 V / 7,2 Ah B 12/ 7,2Ah 24 40100 beacon BE 24 89
www.detectomat.com
Terms & Conditions of Sale detectomat GmbH
102
1 General – Controlling Provisions1. No terms and conditions other than our Terms and Conditions of Sale
contained herein shall apply unless expressly approved in writing by us.Our Terms and Conditions of Sale shall also apply in the event we makedelivery to the customer without objection although aware of the exis-tence of terms and conditions of the customer that differ from our Termsand Conditions of Sale.
2. All agreements made between us and the customer in connection withthe execution of this agreement are contained herein in writing. Thisagreement may not be altered, supplemented or amended unless agreedto in writing.
3. Our Terms and Conditions of Sale shall apply to transactions with busi-nessmen (“Unternehmer”) in the sense of Section 14 German Civil Code,legal entities and public institutions.
4. Our Terms and Conditions of Sale shall also apply to all present andfuture commercial relations with the customer.
2 Acceptance of Orders1. Our offers are subject to change. We reserve the right to make reason-
able technical changes or changes in design, color and/or weight.2. In the case of orders pursuant to Section 145 German Civil Code (BGB),
we may at our option accept such orders within 2 weeks of receipt.3. Unless specified otherwise in these Terms and Conditions of Sale or in
our written confirmation, the INCOTERMS shall apply in the versioneffective as of the date of this agreement.
4. Delivery is contingent upon correct and timely delivery of necessarymaterials or merchandise to us (“Obtaining supplies oneself clause”). Wewill inform the customer without delay in the event of non-availability andpromptly refund any payment received.
5. All rights to illustrations, drawings, calculations and other documentsshall remain our property. This shall also apply to any written materialsdesignated as “confidential”. The customer shall obtain our expressapproval in writing before making any such materials available to otherparties.
3 Prices – Terms of Payment1. Unless specified otherwise in our written confirmation, our prices are “ex
works“ (exw) and exclusive of packing, which will be invoiced separately.2. We reserve the right to modify our prices accordingly in the event of
increases or decreases in costs, including but not necessarily limited toincreases or decreases due to wage agreements or changes in theprices of materials. We will document any such changes at the custo-mer’s request.
3. In the event delivery is to be made more than four months from the dateof acceptance of the order or cannot be made earlier for reasons forwhich the customer is exclusively responsible, we reserve the right toinvoice the appropriate price as of the date of delivery instead of theoriginal price agreed upon.
4. Our prices are exclusive of applicable value added tax (VAT). Applicablevalue added tax will be included separately in the invoice on the billingday.
5. Unless specified otherwise in our written confirmation, the customershall pay the net purchase price (with no deductions) within 10 days ofreceipt of the invoice, at which time the invoice shall become due andpayable. Legal remedies shall apply in the case of past due accounts.
6. The customer may offset amounts due to the customer only if thecorresponding counterclaims are unappealable or undisputed or recog-nized by us. In addition, the customer may exercise the right to withholdpayment only in the case of counterclaims in connection with the sametransaction.
4 Delivery – Delayed Acceptance – Delayed Delivery 1. Delivery dates are subject to timely receipt by us of all documentation to
be supplied by the customer, required permits and approvals, includingbut not necessarily limited to plans, and are also subject to performanceof other obligations by the customer. If these conditions are not fulfilledin due time, delivery shall be delayed accordingly. This shall not apply inthe event of delays for which we are responsible.
2. Our obligation to make delivery is contingent upon timely and properperformance of the customer’s obligations. We reserve the right at ouroption to consider failure to perform (Section 320 German Civil Code - BGB)and impairment of performance (Section 321 German Civil Code - BGB)as events of default.
3. We may make partial delivery if no undue convenience is caused to thecustomer.
4. In the event delivery or shipment is delayed by the customer by morethan one month from the date of announcement to the effect that themerchandise is ready for delivery or shipment, we may invoice thecustomer for storage charges in the amount of 0.5% of the price of therespective merchandise per month or any fraction thereof, in which casesuch charges may not exceed a total of 5%. The parties to the agree-ment may claim higher or lower storage costs if any difference can bedocumented.
5. In the event the customer delays acceptance or fails to perform otherobligations, we may at our option claim reimbursement for any relateddamages sustained by us, including but not necessarily limited toreimbursement for additional expenses, without prejudice to furtherclaims.
6. In the event of a situation pursuant to Section 5 above, risk of loss ordamage shall pass to the customer upon the occurrence of any suchdlay or default on the part of the latter.
7. All acts of God (e.g. mobilization, war, insurrection, strikes, lockout orsimilar events) beyond our control shall release us from performance ofour contractual obligations for the duration of any such occurrences. Wewill immediately inform the customer of our inability to perform ourobligations under the agreement and promptly refund to the customerany corresponding payment received by us . In the event the duration ofsuch an occurrence exceeds a period of three months, we may cancelthe agreement.
8. In the event delivery is delayed by us, our liability is limited to thatprescribed by law if the underlying purchase agreement specifies a firmdelivery date in the sense of Section 286 (2) 4 German Civil Code (BGB)or Section 376 German Commercial Code (HGB) pertaining to non-fulfill-ment. We are also liable as prescribed by law in the sense that thecustomer may claim that it is no longer interested in further performancedue to a delay in delivery caused by us.
9. We are also liable as prescribed by law for any delivery delay due tobreach of the agreement due to willful or gross negligence. We assumeresponsibility for acts of negligence on the part of our representatives oragents. In the event the delivery delay is not due to breach of the agree-ment through willful negligence by us, our liability is limited to claims fordamage that normally could have been anticipated.
10. We are also liable as prescribed by law in the event delivery is delayedthrough breach of a material obligation under the agreement throughnegligence. In such cases, however, liability is limited to claims fordamages normally could have been anticipated.
11. In addition, we are liable for a flatrate penalty for delayed delivery in theamount of 0.5% of the price of the respective merchandise per entireweek, which penalty may, however, not exceed a total of 5%.
12. Any other legal rights and remedies the customer may have shall remainin effect.
www.detectomat.com
Terms & Conditions of Sale detectomat GmbH
103
5 Cancellation1. The customer may cancel the agreement as allowed by law only in the
event of culpable default by us. However, in the case of defects (Section7 below), legal remedies shall apply.
2. The customer shall in the event of default by us inform us within areasonable period after being asked to do so by us whether it intends tocancel the agreement due to the event of the default or whether it insistsupon delivery.
6 Transfer of Risk of Loss or Damage1. Unless specified otherwise in our written confirmation, our prices are under-
stood to be “ex works“ (exw).2. We reserve the right to ship merchandise from locations other than the
place of delivery. At the request of the customer, we will have the merchan-dise insured during transport, in which case the customer shall bear thecorresponding costs.
7 Claims for defects1. Claims for defects may not be made in the event of insignificant devia-
tions from the agreed upon characteristics, insignificant impairment offunctionality, normal wear and tear or damage resulting from improper ornegligent treatment after risk of loss or damage passes to the customer,excessive use, unsuitable operating consumables, improper site prepa-ration or unusual external factors not provided for in the agreement or inthe event of intermittent software problems. In the event of impropermodifications or maintenance by the customer, we can assume noresponsibility for such modifications or maintenance or the ramificationsthereof.
2. The customer’s rights in the case of a defect are dependent upon properinspection and notification in compliance with Section 377 GermanCommercial Code (HGB). Notification of defects must be made in writing.The customer shall bear the burden of proof in connection with all suchclaims, including but not necessarily limited to proof of the existence ofthe defect, the time of occurrence of the defect and timely notification ofthe defect.
3. In the event of notification of a defect, the customer may withholdpayment only in a reasonable amount with respect to the extent of thedefect. The customer may not refuse to accept delivery in the event ofinsignificant defects.
4. In the event of a defect, we may at our option repair the defectivemerchandise or deliver new merchandise free of defects to replace theoriginal merchandise.
5. In the event the repair is unsuccessful, the customer may at its optioncancel the agreement or request a reduction in price. In the event ofnegligible defaults, including but not necessarily limited to negligibledefects, the customer may not cancel the agreement.
6. We are liable as prescribed by law for claims made by the customerbased on willful or gross negligence on the part of our representatives oragents. In cases other than intentional breach of the agreement, ourliability for damages is limited to claims for damages that normally couldhave been anticipated.
7. We are liable as prescribed by law in the event we commit a materialbreach of the agreement. In such cases, however, our liability fordamages is limited to claims for damages that normally could have beenanticipated.
8. We assume liability for injury to the life, body or health throughnegligence on our part. This also applies to compulsory liability pursuantto product liability legislation (“Produkthaftungsgesetz”).
9. Any other form of liability not specified above is excluded.
10. Claims for defects must be reported within 12 months. In the event thenewly manufactured product is a structure or is on the basis of itsnormal function used for a structure and has caused a defect in such astructure, an exception will be made and the period for reporting claimswill be extended to 36 months. Our legal liability pursuant to Sections 6and 8 and in the case of willful deceit shall not be affected.
11. The period for reporting claims pursuant to Sections 478 and 479German Civil Code (BGB) shall not be affected and shall extend for aperiod of five years from the date of delivery of the defective item.Recourse against us pursuant to Section 478 German Civil Code – BGB– (recourse of customer) is only possible in the event the customer hasnot made any agreement with its customer that goes beyond legalliability for defects.
8 General Liability1. Liability for damages other than that provided for in Section 7 is exclu-
ded, regardless of the legal nature of the claim, including but notnecessarily limited to claims for damages due to negligence in connec-tion with the acceptance of the order, other breaches of obligations orclaims for damages to property pursuant to Section 823 German CivilCode (BGB).
2. The exclusion pursuant to Section 8.1 above also applies in the eventthe customer claims reimbursement for needlessly incurred expensesinstead of damages.
3. Insofar as liability for damages is excluded or limited, this shall also applyto claims for damages against our employees, representatives andagents.
9 Usage of software and firmware – industrial property rights1. The customer has the non-exclusive right to use the standard software
and firmware, with the agreed performance characteristics, in anunmodified form and within the agreed devices. The customer may makea backup copy of the standard software without the need for an expressagreement.
2. The goods supplied by us are subject to industrial property rights (e.g.patent rights, trademark rights and ownership rights). The customershall, in the case of applying or using the goods, respect our industrialproperty rights, as well as the industrial property rights of third parties.
10 Retention of Title1. We retain title to the merchandise until all payments from business with
the customer are made in full. In the event the customer has an accountwith us, our reservation of title also applies to any acknowledgedoutstanding balance, and the same applies in the event a balance is notacknowledged and a “balance is made for cause”, for example, in theevent of bankruptcy or insolvency by the customer.
2. In the event of breach of this agreement by the customer, including butnot necessarily limited to failure to make payment when due, we mayretake possession of the merchandise sold without canceling the agree-ment beforehand. The customer hereby agrees to allow us to enter itsbusiness premises during normal business hours to retake possession ofthe items in question in any such situation. After retaking possession ofthe items sold, we may dispose of them and credit the proceeds, lessappropriate disposal costs, to the outstanding balance due us.
3. The customer shall take proper care of the merchandise and shall havethe merchandise adequately insured at new value at its own expenseagainst fire damage, flood damage and theft. In the event maintenanceand inspections are necessary, the customer shall have such workcaried out on a timely basis at its own expense.
www.detectomat.com
Terms & Conditions of Sale and references detectomat GmbH
104
4. In the event of attachment or any other such proceeding initiated bythird parties, the customer shall inform us in writing so that we cantake action pursuant to Section 771 Code of Civil Procedure (ZPO). Inthe event any such third party is not in a position to reimburse us forlegal and extrale-gal expenses resulting from such an action pursuantto Section 771 Code of Civil Procedure (ZPO), the customer shall bearany such expenses.
5. The customer may resell the merchandise in the normal course of itsbusiness. However, the customer shall assign the full invoiced amount(including VAT) due from its customer or other parties from the sale tothe outstanding balance due to us; and this condition shall apply whetheror not the merchandise purchased from us is sold without or afterprocessing. The customer shall remain authorized to collect theamount due after assignment to us. Our right to make collectionourselves remains unaffected. However, we agree to refrain frommaking collection as long as the customer applies the proceeds fromthe sale to meet its payment obligations toward us, is not in arrearsand, in particular, no insolvency proceeds have been opened againstthe customer and the customer has not suspended payment. In anysuch event, we may demand that the customer make known to us theassigned receivables and the corresponding debtors, provide all infor-mation required for collection, make available the correspondingdocuments and inform the debtors (third parties) of the assignment.
6. The processing or modification by the customer of the merchandise isin all cases performed for us. In the event the merchandise is proces-sed with other objects that are not our property, we acquire partialownership of the object in proportion to the value of the merchandise(total invoice amount, including VAT) as compared with that of theother processed objects at the time of the processing. In addition, thesame reservation of title that applies for the merchandise also appliesfor the object that results from the processing.
7. In the event the merchandise is inextricably combined with objectsthat are not our property, we acquire partial ownership of the newobject in proportion to the value of the merchandise (total invoiceamount, includ-ing VAT) as compared with that of the other combinedobjects at the time they are combined. In the event the combination issuch that the property of the customer is to be considered the mainproduct, it is agreed that the customer shall transfer proportionateownership rights to us. The cutomer shall then hold the resultant soleor partial property for us.
8. The customer shall also assign to us those amounts due from thirdparties as a result of the attachment of the merchandise to real esta-te property to secure amounts due to us.
9. In the event the reservation of title or assignment is not effective in thejurisdiction in which the object is located, it is agreed that the securitycorresponding to reservation of title or assignment in that jurisdictionshall obtain. If the creation of this security requires actions on the partof the customer, the latter shall at our request take any and allmeasures required to create and maintain such rights at its ownexpense.
10. We agree to release securities in our favor at the request of the cus-tomer in the event the realizable value of sure securities exceeds thevalue of the secured amounts due by more than 10%. We may deter-mine at our own discretion which securities to release.
11 Support and AssistanceIf, in addition to supplying merchandise, we also provide the customerwith support and/or assistance with the installation/start-up of themerchandise, the limitation of liability described in Sections 7 and 8shall apply accordingly.
12 Venue – Place of Delivery – Governing Law1. This agreement shall be subject to the exclusive jurisdiction of the
courts of our principal place of business in the event the customer isa businessman in the sense of Section 14 German Civil Code (BGB), alegal entity or a public institution. We may, however, file suit againstthe customer before the courts of the customer’s principal place ofbusiness.
2. In the event the customer is a businessman in the sense of Section 14German Civil Code (BGB), a legal entity or a public institution and noth-ing is specified to the contrary in our written confirmation, our princi-pal place of business shall be the place of delivery.
3. This agreement shall be governed by the laws of the Federal Republicof Germany.Application of the United Nations Convention on Contracts forthe International Sale of Goods (1980) – CISG – is expressly excluded.
4. In the event of differences of opinion arising from these Terms andConditions of Sale or in the case of doubt, the original German-languageversion and it alone shall be legal and binding.
Terms & Conditions of Sale detectomat GmbH, revised 15. August 2006
Technical ModificationsDue to continuous development of our products, together with alteringmanufacturing methods, the descriptions and data provided are for informa-tion only and subject to changes without notice.
Information given in the catalogueWe accept no responsibility for the accuracy of the information and pricesgiven in the catalogue. Our prices are exclusive of applicable value added tax(VAT). Applicable value added tax will be included separately in the invoice onthe billing day.
Updates you will find at www.detectomat.com
detectomat GmbHAn der Strusbek 5, 22926 Ahrensburg, GermanyAmtsgericht Lübeck, HR B 4645 AH
President:Dipl.-Ing. Eduard J. Job
CFO:Dipl.-Ing. Bodo Müller
www.detectomat.com
The Group
detectomat GmbHAn der Strusbek 5D-22926 AhrensburgGermany
Tel.: +49 (0) 4102 – 2114 – 60
Fax: +49 (0) 4102 – 2114 – 670
E-Mail: [email protected]
Web: www.detectomat.com
detectomat GmbH Werk BielefeldElpke 106–108D-33605 Bielefeld, Germany
Tel.: +49 (0) 521 – 924 31 – 0
Fax: +49 (0) 521 – 924 31 – 50
E-Mail: [email protected]
Web: www.detectomat.com
JOB GmbH Kurt-Fischer-Straße 30D-22926 AhrensburgGermany
Tel.: +49 (0) 4102 – 2114 – 0
Fax: +49 (0) 4102 – 2114 – 70
E-Mail: [email protected]
Web: www.Job-Bulbs.com