55
http://catalog.moeller.net Frequency inverters DF Vector frequency inverters DV Frequency inverters allow an infinitely variable speed control of three-phase motors through the continuous control of the voltage/frequency ratio (U/f inverter) or through sensorless flow control (vector inverter). DV51 - Sensorless vector inverter - System device with direct surface mounting possibility for optional operator control and communication modules (DE…) - Rating range 1.6…16 A, 0.25…7.5 kW (at 400 V) Page 15/12 DV6 - Flow-controlled vector inverter - Closed-loop/open-loop (sensorless) - Parameterizable and communication-capable - Rating range 2.5…260 A, 0.75…132 kW (at 400 V) Page 15/23 DF51 - U/f inverter - Compact device with built-in keypad - Rating range 1.4…16 A, 0.25…7.5 kW (at 400 V) Page 15/6 DF6 - U/f inverter - Parameterizable and communication-capable - Rating range 22…253 A, 11…132 kW (at 400 V) Page 15/18 Page Overview of frequency inverters 15/2 System overview Frequency inverters DF51 15/4 Frequency inverters DF6 15/16 Description Frequency inverters DF51 15/5 Frequency inverters DF6 15/17 Ordering Frequency inverters DF51 15/6 Frequency inverters DF6 15/18 Engineering Assigned switching and protective elements DF51 15/7 Connection example DF51 15/8 Assigned switching and protective elements DF6 15/19 Connection example DF6 15/20 Technical data Frequency inverters DF51 15/39 Frequency inverters DF6 15/46 Dimensions Frequency inverters DF51 15/61 Frequency inverters DF6 15/62 Page Overview of frequency inverters 15/3 System overview Vector frequency inverters DV51 15/10 Vector frequency inverters DV6 15/21 Description Vector frequency inverters DV51 15/11 Vector frequency inverters DV6 15/22 Ordering Vector frequency inverters DV51 15/12 Vector frequency inverters DV6 15/23 Engineering Assigned switching and protective elements DV51 15/13 Connection example DV51 15/14 Assigned switching and protective elements DV6 15/24 Connection example DV6 15/25 Technical data Vector frequency inverters DV51 15/42 Vector frequency inverters DV6 15/50 Dimensions Vector frequency inverters DV51 15/61 Vector frequency inverters DV6 15/62 Page Description Keypads 15/26 Accessories 15/27 Interface modules 15/28 Reactors 15/30 Braking units, braking resistances 15/31 Engineering Connection examples 15/32 Ordering Accessories 15/33 Interface modules 15/34 Radio interference suppression filter 15/35 Mains chokes 15/36 Motor reactors, braking units, braking resistances 15/37 Technical data Radio interference suppression filter 15/57 Line reactors, motor reactors 15/59 Dimensions Accessories 15/62 Radio interference suppression filter 15/64 Line reactors, motor reactors 15/65 Frequency inverters DF, Vector frequency inverters DV Accessories DEV, DEX Vector frequency inverters DV51/DV6 Frequency inverters DF51/DF6 Contents Moeller HPL0211-2007/2008 15/1

Kapitel 15 G Online

Embed Size (px)

Citation preview

Page 1: Kapitel 15 G Online

http://catalog.moeller.net

Frequency inverters DFVector frequency inverters DV

Frequency inverters allow an infi nitely variable speed control of three-phase motors through the continuous control of the voltage/frequency ratio (U/f inverter) or through sensorless fl ow control (vector inverter).

DV51- Sensorless vector inverter- System device with direct

surface mounting possibility for optional operator control and communication modules (DE…)

- Rating range 1.6…16 A, 0.25…7.5 kW (at 400 V)

Page 15/12

DV6- Flow-controlled vector

inverter- Closed-loop/open-loop

(sensorless)- Parameterizable and

communication-capable- Rating range 2.5…260 A,

0.75…132 kW (at 400 V)

Page 15/23

DF51- U/f inverter- Compact device with built-in

keypad- Rating range 1.4…16 A,

0.25…7.5 kW (at 400 V)

Page 15/6

DF6 - U/f inverter - Parameterizable and

communication-capable - Rating range 22…253 A,

11…132 kW (at 400 V)

Page 15/18

Page

Overview of frequency inverters 15/2

System overview

Frequency inverters DF51 15/4

Frequency inverters DF6 15/16

Description

Frequency inverters DF51 15/5

Frequency inverters DF6 15/17

Ordering

Frequency inverters DF51 15/6

Frequency inverters DF6 15/18

Engineering

Assigned switching and protective elements DF51

15/7

Connection example DF51 15/8

Assigned switching and protective elements DF6

15/19

Connection example DF6 15/20

Technical data

Frequency inverters DF51 15/39

Frequency inverters DF6 15/46

Dimensions

Frequency inverters DF51 15/61

Frequency inverters DF6 15/62

Page

Overview of frequency inverters 15/3

System overview

Vector frequency inverters DV51 15/10

Vector frequency inverters DV6 15/21

Description

Vector frequency inverters DV51 15/11

Vector frequency inverters DV6 15/22

Ordering

Vector frequency inverters DV51 15/12

Vector frequency inverters DV6 15/23

Engineering

Assigned switching and protective elements DV51

15/13

Connection example DV51 15/14

Assigned switching and protective elements DV6

15/24

Connection example DV6 15/25

Technical data

Vector frequency inverters DV51 15/42

Vector frequency inverters DV6 15/50

Dimensions

Vector frequency inverters DV51 15/61

Vector frequency inverters DV6 15/62

Page

Description

Keypads 15/26

Accessories 15/27

Interface modules 15/28

Reactors 15/30

Braking units, braking resistances 15/31

Engineering

Connection examples 15/32

Ordering

Accessories 15/33

Interface modules 15/34

Radio interference suppression fi lter 15/35

Mains chokes 15/36

Motor reactors, braking units, braking resistances

15/37

Technical data

Radio interference suppression fi lter 15/57

Line reactors, motor reactors 15/59

Dimensions

Accessories 15/62

Radio interference suppression fi lter 15/64

Line reactors, motor reactors 15/65

Freq

uen

cy in

vert

ers

DF,

Vec

tor

freq

uen

cy in

vert

ers

DVAccessories DEV, DEXVector frequency inverters DV51/DV6Frequency inverters DF51/DF6

ContentsMoeller HPL0211-2007/2008

15/1

Page 2: Kapitel 15 G Online

15/2Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

Frequency Inverters – Overview

U/f inverters DF51-320 DF51-322 DF51-340 DF6-340

Rated voltage(50/60Hz g5%)

230 V AC 230 V AC 400 V AC 400 V AC

1 AC 180…264 V g 0% – K – –3 AC 180…264 V g 0% K K – –3 AC 342…528 V g 0% – – K K

Rated operational current 15.9…32 A 1.4…10 A 1.5…16 A 22 … 230 AAssigned motor rating at rated voltage 4…7.5 kW 0.25…7.5 kW 0.37…7.5 kW 11 … 132 kW

PID controller K K K K

Built-in braking chopper (external braking resistance) – – – Only DF6-340-11Kand DF6-340-15K

Keypad K K K K

Communication interface RS 485, Modbus RTU (optionally PROFIBUS-DP, CANopen) RS 422, RS 485, (optionally PROFIBUS-DP)

Product standard EN 50178, IEC 61800-3Approvals CE, UL, c-UL, cTick CE, UL, c-UL,CSA, cTickDegree of protection IP20

Ambient temperatureOperating temperature °C -10 to +40 with rated current Ie at a clock frequency of 5 kHz; up to +50 °C at a reduced clock frequency of 2 kHz

and reduced output current of 80 % Ie.Storage °C –25…+70

Mechanical shock resistance Vibration and impact, max. 5.9 m/s2 (0.6 g) at 10 to 55 HzPollution degree VDE 0110 Part 2, pollution degree 2Climatic proofing Class 3K3 according to EN 50178 (non-condensing, average relative humidity 20 to 90 %)Altitude m 0 to 1000 m a.s.l., above 1000 m with reduced current (2.5 %/100 m)Mounting position Vertically suspendedFree surrounding areas 100 mm above and below deviceEmitted interference IEC/EN 61800-3 (EN 55011 group 1 class B)Noise immunity IEC/EN 61800-3, industrial environmentInsulation resistance Overvoltage category III according to VDE 0110Leakage current to PE mA < 3.5 (to EN 50178)Contact protection Finger and back-of-hand proofProtective isolation from switching circuitry

Safe isolation from the mains. Double basic isolation (to EN 50178)

Protective measures Overcurrent, earth fault, overvoltage, undervoltage, overload, overtemperature, electronic overload protection: I2t monitoring and PTC input (thermistor or thermostat)

Notes If the frequency inverter is to be installed in an enclosure, control panel or similar housing, the ambient temperature Ta is taken to be the temperature inside this enclosure or control panel.All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, for operation of a four-pole three-phase asynchronous motor.

DF51, DF6

Page 3: Kapitel 15 G Online

15/3

http://catalog.moeller.net Moeller HPL0211-2007/2008

Frequency Inverters – Overview

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Vector inverters DV51-320 DV51-322 DV51-340 DV6-340

Rated voltage(50/60Hz g5%)

230 V AC 230 V AC 400 V AC 400 V AC

1 AC 180…264 V g 0 % – K – –3 AC 180…264 V g 0 % K K – –3 AC 342…528 V g 0 % – – K K

Rated operational current 17.5…32 A 1.6…11 A 1.5…16 A 2.8…286 AAssigned motor rating at rated voltage 4…7.5 kW 0.25…7.5 kW 0,37…7.5 kW 0.75 … 132 kW

PID controller K K K K

Built-in braking chopper (external braking resistance) K K K DV6-340-075 … DV6-340-11K

Keypad Option DEX-KEY-6…, DEX-KEY-10 K

Communication interface RS 485, Modbus RTU (optionally PROFIBUS-DP, CANopen) RS 422, RS 485, (optionally PROFIBUS-DP)

Product standard EN 50178, IEC 61800-3Approvals CE, UL, c-UL, cTick CE, UL, c-UL,CSA, cTickDegree of protection IP20

Ambient temperatureOperating temperature °C -10 to +40 with rated current Ie at a clock frequency of 5 kHz; up to +50 °C at a reduced clock frequency of 2 kHz

and reduced output current of 80 % Ie.Storage °C –25…+70

Mechanical shock resistance Vibration and impact, max. 5.9 m/s2 (0.6 g) at 10 to 55 HzPollution degree VDE 0110 Part 2, pollution degree 2Climatic proofing Class 3K3 according to EN 50178 (non-condensing, average relative humidity 20 to 90 %)Altitude m 0 to 1000 m a.s.l., above 1000 m with reduced current (2.5 %/100 m)Mounting position Vertically suspendedFree surrounding areas 100 mm above and below deviceEmitted interference IEC/EN 61800-3 (EN 55011 group 1 class B)Noise immunity IEC/EN 61800-3, industrial environmentInsulation resistance Overvoltage category III according to VDE 0110Leakage current to PE mA < 3.5 (to EN 50178)Contact protection Finger and back-of-hand proofProtective isolation from switching circuitry

Safe isolation from the mains. Double basic isolation (to EN 50178)

Protective measures Overcurrent, earth fault, overvoltage, undervoltage, overload, overtemperature, electronic overload protection: I2t monitoring and PTC input (thermistor or thermostat)

Notes If the frequency inverter is to be installed in an enclosure, control panel or similar housing, the ambient temperature Ta is taken to be the temperature inside this enclosure or control panel.All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, for operation of a four-pole three-phase asynchronous motor.

DV51

Page 4: Kapitel 15 G Online

15/4Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

System overviewFrequency inverters

Base units System accessories Accessories

Frequency inverters 1 Communication modules 6 Radio interference suppression filter 2DF51-322-... CANopen interface a page 15/35Mains: 230 V single-phase/3-phase PROFIBUS-DP interface Mains reactors 3Motor rating from 0.25 to 2.2 kW (230 V) a page 15/34 a page 15/36a page 15/6 Mounting frame 5 Motor reactor 3

for commumication modules a page 15/37DF51-320-... 1 a page 15/34 Connection cable 4Mains: 230 V 3-phase Connection cable for external LCD keypadMotor ratingsfrom 4 to 7.5 kW (230 V)

a page 15/33

a page 15/6 Keypads 7, 8External LCD keypad with/without memory function

DF51-340-... 1 a page 15/33Mains: 400 V 3-phase Mounting frame 9Motor ratingfrom 0.37 to 7.5 kW (400 V)

Mounting frame for externalLCD keypad

a page 15/6 a page 15/33

2

9

7Hz

A

RUN

PRGENTER

A

RUN

PRG

Hz

POWER

ALARM

4

Hz

A

RUN

PRG

PRGENTER

POWER

ALARM

8

1

36

5

COPY

POWER

RUNPRG

REVFWD

ALARM

READCOPY

ENTERPRG

MNT

RMT

DF51

Page 5: Kapitel 15 G Online

15/5

http://catalog.moeller.net Moeller HPL0211-2007/2008

DescriptionFrequency Inverters

Freq

uenc

y in

vert

ers

DF5

1 ve

ctor

freq

uenc

y in

vert

ers

DV5

1

The frequency inverters of the DF51 series provide infinitely variable speed control of three-phase motors. They are especially suitable for applications where simple operation and economic efficiency are important.The assigned performance range for four-pole three-phase asynchronous motors ranges from:

• 0.25 to 2.2 kW with single-phase power supply (230 V)• 0.25 to 7.5 kW with three-phase power supply (230 V)• 0.37 to 7.5 kW with three-phase power supply (400 V)

The frequency inverter DF51 can be used as a stand-alone drive or incorporated in automation systems. With its / (voltage/frequency) characteristic control, it can be used in wide range of applications, from simple pump and fan drives through standard transportation and conveying applications to flexible use the machine tool and packaging machine industry.

• Compact construction due to highly-integrated module technology• Integrated keypad with four-character seven-segment display, LEDs, six

function keys and a setpoint value potentiometer• Serial interface (RS 485, Modbus RTU)• Five digital inputs (24 V DC)• Two digital outputs (24 V DC)• Two analog inputs (0 to +10 V, 4 to 20 mA)• One analog output (0 to +10 V)• A relay (changeover contact: 24 V DC/230 V AC)• Thermistor input• User-friendly direct operation without prior configuration.• Conformance to global standards CE, UL, c-UL and cTick

Comprehensive protective functions guarantee safe operation and protect frequency inverters and motors:

• Overcurrent, earth fault• Overload, electronic motor protection• Overtemperature• Overvoltage, undervoltage• Restart inhibit

Additional operational functions:• > 100 % starting torque from about 6 Hz• PID controller• Automatic voltage control (boost)• Min./max. frequency limitation• Electronic motor potentiometer function• Frequency hopping (frequency masking)• DC braking to motor standstill• Up to 16 fixed speeds• PLC functionality: Linkage of digital in- and outputs

• Each DF51 vector frequency inverter is supplied with installation instructions and a CD.

• The AWA contains a short description with illustrations and information about correct handling, installation and electrical connection of the device. The information supplied is printed in seven languages (English, Chinese, French, German, Italian, Russian, and Spanish).

• The CD contains a detailed manual (at least English, German) and configuration software with help text.

• Documentation and parameterization software are also available for download from the Internet:www.moeller.net/support

Note:The software on the CD can be run on PCs with the current Windows operating systems (from 98 to XP). For connecting a PC (RS 232) to a DF51 frequency inverter, you will need the connection cable DEX-CBL-2M0-PC.

Application

Features

Functions

Documentation

DF51

Page 6: Kapitel 15 G Online

15/6Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

OrderingFrequency inverters

Rated voltage Max. rated operational current

Rated power for motors

Part no.Article no.

Pricesee price list

Std. pack

Ue Ie

V A P

kW

Frequency Inverters DF51Frequency inverters 0.25 kW to 2.2 kW at 230 V, one- and three-phase connection

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

1.4 0.25 DF51-322-025289102

1 off

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

2.6 0.37 DF51-322-037289103

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

3 0.55 DF51-322-055289104

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

4 0.75 DF51-322-075289105

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

5 1.1 DF51-322-1K1289106

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

7.1 1.5 DF51-322-1K5289107

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

10 2.2 DF51-322-2K2289108

Frequency inverters 4 kW to 7 kW at 230 V, three-phase connection1)

3 AC 180…264 V g 0 % 15.9 4 DF51-320-4K0289109

1 off

3 AC 180…264 V g 0 % 24 5.5 DF51-320-5K5289120

3 AC 180…264 V g 0 % 32 7.5 DF51-320-7K5289121

Frequency inverters 0.37 kW to 7.5 kW at 400 V, three-phase connection3 AC 342…528 V g 0 % 1.5 – DF51-340-037

2891221 off

3 AC 342…528 V g 0 % 2.5 – DF51-340-075289123

3 AC 342…528 V g 0 % 3.8 – DF51-340-1K5289124

3 AC 342…528 V g 0 % 5.5 – DF51-340-2K2289125

3 AC 342…528 V g 0 % 7.8 – DF51-340-3K0289126

3 AC 342…528 V g 0 % 8.6 – DF51-340-4K0289127

3 AC 342…528 V g 0 % 13 – DF51-340-5K5289128

3 AC 342…528 V g 0 % 16 – DF51-340-7K5289129

Notes 1) All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, for operation of a four-pole three-phase asynchronous motor.

DF51

Page 7: Kapitel 15 G Online

15/7

http://catalog.moeller.net Moeller HPL0211-2007/2008

EngineeringFrequency inverters

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Motor Frequency inverters Power supply Motor connection

Assigned motor rating

Rated operational current

Mains current

Short-circuit and line protection (fuse)

Mains contactor Mains reactor1) Radio interference suppression filter

Motor reactor

Without mains reactor/filter

P Ie INkW A A

Frequency inverters DF51 Single-phase power supply (230 V AC)

DF51-322-025 0.25 1.4 3.1 FAZ-B10/1N3) DILM7 DEX-LN1-006 DE51-LZ1-007-V2 DEX-LM3-005DF51-322-037 0.37 2.6 5.8 FAZ-B10/1N3) DILM7 DEX-LN1-006 DE51-LZ1-007-V2 DEX-LM3-005DF51-322-055 0.55 3 6.7 FAZ-B10/1N3) DILM7 DEX-LN1-009 DE51-LZ1-007-V2 DEX-LM3-005DF51-322-075 0.75 4 9 FAZ-B16/1N3) DILM7 DEX-LN1-009 DE51-LZ1-012-V2 DEX-LM3-005DF51-322-1K1 1.1 5 11.2 FAZ-B16/1N3) DILM7 DEX-LN1-013 DE51-LZ1-012-V2 DEX-LM3-005DF51-322-1K5 1.5 7.1 16 FAZ-B20/1N3) DILM7 DEX-LN1-018 DE51-LZ1-024-V2 DEX-LM3-008DF51-322-2K2 2.2 10 22.5 FAZ-B32/1N3) DILM7+DILM12-XP1 DEX-LN1-024 DE51-LZ1-024-V2 DEX-LM3-011Frequency inverters DF51Three-phase power supply (230 V AC)

DF51-322-025 0.25 1.4 1.8 PKM0-10 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DF51-322-037 0.37 2.6 3.4 PKM0-10 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DF51-322-055 0.55 3 3.9 PKM0-10 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DF51-322-075 0.75 4 5.2 PKM0-16 DILM7 DEX-LN3-006 DE51-LZ3-007-V4 DEX-LM3-005DF51-322-1K1 1.1 5 6.5 PKM0-16 DILM7 DEX-LN3-006 DE51-LZ3-007-V4 DEX-LM3-005DF51-322-1K5 1.5 7.1 9.3 PKM0-16 DILM7 DEX-LN3-010 DE51-LZ3-011-V4 DEX-LM3-008DF51-322-2K2 2.2 10 13 PKM0-20 DILM7 DEX-LN3-016 DE51-LZ3-020-V4 DEX-LM3-011DF51-320-4K0 4 15.9 20 PKM0-32 DILM17 DEX-LN3-025 – 2) DEX-LM3-016DF51-320-5K5 5.5 24 30 PKZM-40 DILM17 DEX-LN3-040 – 2) DEX-LM3-035DF51-320-7K5 7.5 32 40 PKZM-50 DILM25 DEX-LN3-040 – 2) DEX-LM3-035Frequency inverters DV51Three-phase power supply (400 V AC)

DF51-340-037 0.37 1.5 2 PKM0-4 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DF51-340-075 0.75 2.5 3.3 PKM0-6,3 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DF51-340-1K5 1.5 3.8 5 PKM0-10 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DF51-340-2K2 2.2 5.5 7 PKM0-10 DILM7 DEX-LN3-006 DE51-LZ3-007-V4 DEX-LM3-008DF51-340-3K0 3 7.8 10 PKM0-16 DILM7 DEX-LN3-010 DE51-LZ3-011-V4 DEX-LM3-008DF51-340-4K0 4 8.6 11 PKM0-16 DILM7 DEX-LN3-010 DE51-LZ3-011-V4 DEX-LM3-011DF51-340-5K5 5.5 13 16.5 PKM0-20 DILM7 DEX-LN3-016 DE51-LZ3-020-V4 DEX-LM3-016DF51-340-7K5 7.5 16 20 PKM0-25 DILM17 DEX-LN3-025 DE51-LZ3-020-V4 DEX-LM3-016

Notes: 1) Mains chokes reduce the line currents by up to 30 % and extend the frequency inverters’ lifespan.2) No device assigned yet.3) Where single-phase frequency inverters are used on mains without line reactor (for example with reactive-power compensation equipment or UPS),

current peaks can occur when the mains contactor is switched on, and these can cause the FAZ-B... to trip prematurely. Remedy: fit a mains reactor upstream or use a FAZ-C…

Line protection with FAZ, PKM or PKZM (PKZM0 can be used instead of PKM0) a section 12, 8 Mains contactors DIL a section 5 Main chokes DEX-LN… a page15/36Motor chokes DEX-LM3-… a page 15/37SFB400/... sine-wave filters please enquire

DF51

Page 8: Kapitel 15 G Online

15/8Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

EngineeringConnection example

Block diagram DF51

In their default configuration, the DF51 frequency inverters can be used at their assigned supply voltage and motor rating (four-pole, three-phase asynchronous motor) without any parameter changes. Their acceleration and deceleration times are set to 15 seconds. The control signal inputs and outputs have the following assigned functions:Terminal 1: FWD = Clockwise rotating field enable (Forward)Terminal 2: REV = Anticlockwise rotating field enable (Reverse)Terminal 3: FF1 = Fixed frequency 1

Terminal 4: FF2 = Fixed frequency 2Terminal 5: RST = Reset, can be configured as thermistor input with

parameter C005.Terminal 11: FA1 = Frequency arrival, type 1 (output frequency actual value

= reference input)Terminal 12: RUN = Running Terminals K11-K12:

Relay, fault signal (K11-K14 ready for operation)

Through the built-in keypad, all parameters and functions can be adapted to the application.

5L

i

*

0 V

+10 V

0 V

PEW

VU

M 3 ~

K11

K12

K14

e

AMH

OO

IL

CM2

1211

0...10 V

RUN

FA1

4...20 mA

0...10 V

– +

–+

L+ DC–

DC+

PEL3

L2L1

3 1

PEN

L

FF2

FF1

REV

FWD

32

14

P24

+24

V

RJ 4

5M

odBu

s

RST

* PN

U C0

05 =

19

(PTC

)

DF51

Page 9: Kapitel 15 G Online

15/9

http://catalog.moeller.net Moeller HPL0211-2007/2008

EngineeringConnection example

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

a Connection option for single-phase connection of a 2.2 kW drive (DF51-322-2K2) required!

Connection example for a 0.75 kW motor with the ratings plate illustrated below. Variant A: Motor connected in a delta circuit, DF51 with single-phase

mains supply (230 V).Variant B: Motor connected in a star circuit, DF51 with three-phase mains

supply (400 V).

Motor: P = 0.75 kW The 0.75 kW motor described below can be delta-connected to a single-phase 230 V mains (version A) or star-connected to a 400 V mains.Depending on the mains voltage, a DF5-322 frequency inverter is selected for 230 V single-phase AC, or a DF5-340 for 400 V 3-phase AC, together with the corresponding accessories.

Mains: 3/N/PE 400 V, 50/60 HzEMC-conformant connection examples: power section

PE

LNPE

2

L N

1

R1

a

PE

PE

1 h 230 V, 50/60 Hz

L

K1

T1

N

Q1

DC+ DC–L+ U V W PE

PES

PES

PES

PES

MM1

X1

3 ~

F1FAZ-1N-B16

DEX-LN1-009

DE51-LZ1-012-V2

DF51-322-075

230 V3.5 A

0.75 kW

DILM7+DILM12-XP1

e

U1 V1 W1

W2 U2 V2

3 h 400 V, 50/60 Hz

W2

L1 L2 L3 PE

L1L2L3PE

Q11

Q1

V2U2

L1 L2 L3

W1V1U1

R1

K1

PE

PE

III

U1 V1 W1

W2 U2 V2

T1 DC+ DC–L+ U V W PE

PES

PES

PES

PES

MM1

X1

3 ~

PKM0-6,3

DEX-LN3-004

DE51-LZ3-007-V4

DF51-340-075

400 V2 A

0.75 kW

DILM7

e

/ 400 V230 4.0 / 2.30,75S1 0.67ϕcoskW

rpm1410 50 Hz

A

DF51

Page 10: Kapitel 15 G Online

15/10Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

System overviewVector frequency inverters

Basic devicesVector frequency inverters 1DV51-322-...Mains: 230 V single-phase/3-phaseMotor rating vfrom 0.25 to 2.2 kW (230 V)a page 15/12DV51-320-... 1Mains: 230 V 3-phaseMotor ratingfrom 4 to 7.5 kW (230 V)a page 15/12DV51-340-... 1Mains: 400 V 3-phaseMotor ratingfrom 0.37 to 7.5 kW (400 V)a page 15/12

POWERALARMRUN

6

9

10

11

7

4

8

7 1

3

5

2Hz

A

RUN

PRG

PRGENTER

POWER

ALARM

POWERALARM

RUN

1 2

OFF

OPERBUS

COPY

POWER

RUNPRG

REVFWD

ALARM

READCOPY

ENTERPRG

MNT

RMT

System accessoriesCommunication modules 6RS 485 T adapter modulea page 15/33Communication modules 7CANopen interfacePROFIBUS DP interfacea page 15/34Mounting frames 8Adapter for LCD keypad DEX-KEY-6… in combination with the communication modules a page 15/34Mounting frames 11For external LCD keypada page 15/33

AccessoriesRadio interference suppression filter 2a page 15/35Line reactors 3a page 15/36Motor reactors 3a page 15/37Braking resistor 4Enclosed (IP 20) high-capacity resistors with temperature switch, for connecting to the DV51’s braking transistora page 15/37Connection cables 5Connection cable for external display and control unitsa page 15/33Keypad 9, 10External keypad with/withoutmemory function a page 15/33

DV51

Page 11: Kapitel 15 G Online

15/11

http://catalog.moeller.net Moeller HPL0211-2007/2008

DescriptionVector frequency inverters

Freq

uenc

y in

vert

ers

vect

or fr

eque

ncy

inve

rter

s

With their sensorless vector control, the DV51 frequency inverters offer excellent torque levels for three-phase motors with cage rotors. They are especially suitable for demanding applications in which maximum torque and smooth running are required at the lower speed range. The assigned performance range for four-pole three-phase asynchronous motors ranges from:

• 0.25 to 2.2 kW with single-phase power supply (230 V)• 0.25 to 7.5 kW with three-phase power supply (230 V)• 0.37 to 7.5 kW with three-phase power supply (400 V)

The vector frequency inverters DV51 can be used as a stand-alone drive or incorporated in automation systems. The adaptable modules allow flexible communication. With the sensorless vector control, applications in the plastics and metal processing, textile, paper and printing industries and in crane and lift installations are possible.

• Compact construction due to highly-integrated module technology• Internal braking transistor• Optional keypads DEX-KEY-6…• Optional fieldbus module (CAN, PROFIBUS DP)• Serial interface (RS 485, Modbus RTU)• Six digital inputs (24 V DC)• Two digital outputs (24 V DC)• Two analog inputs (0 to +10 V, 4 to 20 mA)• One analog output (0 to +10 V)• A relay (changeover contact: 24 V DC/230 V AC)• Thermistor input• User-friendly direct operation without prior configuration.• Conformance to global standards CE, UL, c-UL and cTick

Comprehensive protective functions guarantee safe operation and protect frequency inverters and motors:

• Overcurrent, earth fault• Overload, electronic motor protection• Overtemperature• Overvoltage, undervoltage• Restart inhibit

Additional operational functions:• Sensorless Vector Control• 200 % starting torque from approx 1 Hz• Dynamic braking (external braking resistor)• Electronic motor potentiometer function• PID controller• Automatic voltage control (boost)• Min./max. frequency limitation• Frequency hopping (frequency masking)• DC braking to motor standstill• Up to 16 fixed speeds• PLC functionality: Linkage of digital in- and outputs

• Each vector frequency inverter DV51 is supplied with an installation instruction (AWA) and a CD.

• The installation instruction contains a short description with illustrations and information about correct handling, installation and electrical connection of the device. The information supplied is printed in seven languages (English, Chinese, French, German, Italian, Russian, and Spanish).

• The CD contains a detailed manual (at least English, German) and configuration software with help text.

• Documentation and parameterization software are also available for download from the Internet:www.moeller.net/support

Note:The software on the CD can be run on PCs with the current Windows operating systems (from 98 to XP). For connecting a PC (RS 232) to a vector frequency inverter DV51, you will need the connection cable DEX-CBL-2M0-PC (with integrated interface converter).

Application

Features

Functions

Documentation

DV51

Page 12: Kapitel 15 G Online

15/12Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

OrderingVector frequency inverters

Rated voltage Max. rated operational current

Rated power for motors Part no.Article no.

Pricesee price list

Std. pack

Ue Ie at 230 V 3-phase AC

V A P

kW

Vector frequency inverters DV51

The DV51 vector frequency inverters are supplied without LCD keypad. Order keypad DEX-KEY-6… separately.Vector frequency inverters 0.25 kW to 2.2 kW at 230 V, single- and three-phase connection

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

1.6 0.25 DV51-322-025285016

1 off

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

2.6 0.37 DV51-322-037285017

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

3 0.55 DV51-322-055285018

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

4 0.75 DV51-322-075285019

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

5 1.1 DV51-322-1K1285030

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

8 1.5 DV51-322-1K5285031

1 AC 180…264 V g 0 %3 AC 180…264 V g 0 %

11 2.2 DV51-322-2K2285032

Vector frequency inverters 4 kW to 7.5 kW at 230 V, three-phase connection1)

3 AC 180…264 V g 0 % 17.5 4 DV51-320-4K0285033

1 off

3 AC 180…264 V g 0 % 24 5.5 DV51-320-5K5285034

3 AC 180…264 V g 0 % 32 7.5 DV51-320-7K5285035

Vector frequency inverters 0.37 kW to 7.5 kW at 400 V, three-phase connection3 AC 342…528 V g 0 % 1.5 – DV51-340-037

2850361 off

3 AC 342…528 V g 0 % 2.5 – DV51-340-075285037

3 AC 342…528 V g 0 % 3.8 – DV51-340-1K5285038

3 AC 342…528 V g 0 % 5.5 – DV51-340-2K2285039

3 AC 342…528 V g 0 % 7.8 – DV51-340-3K0285040

3 AC 342…528 V g 0 % 8.6 – DV51-340-4K0285041

3 AC 342…528 V g 0 % 13 – DV51-340-5K5285042

3 AC 342…528 V g 0 % 16 – DV51-340-7K5285043

Notes All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, for operation of a four-pole three-phase asynchronous motor.

DV51

Page 13: Kapitel 15 G Online

15/13

http://catalog.moeller.net Moeller HPL0211-2007/2008

EngineeringAssigned switching and protective elements

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Motor Frequency inverters Mains contactor Motor connec-tion

Assigned motor rating

Rated opera-tional cur-rent

Mains cur-rent

Mains fuse Mains contactor Mains choke1) Radio interference suppression filter

Motor reactor

Without mains re-actor/filter

P Ie INkW A A

Frequency inverter DV51, single-phase mains connection(230 V AC)DV51-322-025 0.25 1.6 3.5 FAZ-B10/1N1) DILM7 DEX-LN1-006 DE51-LZ1-007-V2 DEX-LM3-005DV51-322-037 0.37 2.6 5.8 FAZ-B10/1N1) DILM7 DEX-LN1-006 DE51-LZ1-007-V2 DEX-LM3-005DV51-322-055 0.55 3 6.7 FAZ-B10/1N1) DILM7 DEX-LN1-009 DE51-LZ1-007-V2 DEX-LM3-005DV51-322-075 0.75 4 9 FAZ-B16/1N1) DILM7 DEX-LN1-009 DE51-LZ1-012-V2 DEX-LM3-005DV51-322-1K1 1.1 5 11.2 FAZ-B16/1N1) DILM7 DEX-LN1-013 DE51-LZ1-012-V2 DEX-LM3-005DV51-322-1K5 1.5 8 17.5 FAZ-B20/1N1) DILM7 DEX-LN1-018 DE51-LZ1-024-V2 DEX-LM3-008DV51-322-2K2 2.2 11 24 FAZ-B32/1N1) DILM7+DILM12-XP1 DEX-LN1-024 DE51-LZ1-024-V2 DEX-LM3-011Frequency inverter DV51 Three-phase power supply (230 V AC)DV51-322-025 0.25 1.6 2 PKM0-10 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DV51-322-037 0.37 2.6 3.4 PKM0-10 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DV51-322-055 0.55 3 3.9 PKM0-10 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DV51-322-075 0.75 4 5.2 PKM0-16 DILM7 DEX-LN3-006 DE51-LZ3-007-V4 DEX-LM3-005DV51-322-1K1 1.1 5 6.5 PKM0-16 DILM7 DEX-LN3-006 DE51-LZ3-007-V4 DEX-LM3-005DV51-322-1K5 1.5 8 10 PKM0-16 DILM7 DEX-LN3-010 DE51-LZ3-011-V4 DEX-LM3-008DV51-322-2K2 2.2 11 14 PKM0-20 DILM7 DEX-LN3-016 DE51-LZ3-020-V4 DEX-LM3-011DV51-320-4K0 4 17.5 22 PKZM0-32 DILM17 DEX-LN3-025 – 2) DEX-LM3-035DV51-320-5K5 5.5 24 30 PKZM0-40 DILM17 DEX-LN3-040 – 2) DEX-LM3-035DV51-320-7K5 7.5 32 40 PKZM0-50 DILM25 DEX-LN3-040 – 2) DEX-LM3-035Frequency inverter DV51 Three-phase power supply (400 V AC)DV51-340-037 0.37 1.5 2 PKM0-4 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DV51-340-075 0.75 2.5 3.3 PKM0-6,3 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DV51-340-1K5 1.5 3.8 5 PKM0-10 DILM7 DEX-LN3-004 DE51-LZ3-007-V4 DEX-LM3-005DV51-340-2K2 2.2 5.5 7 PKM0-10 DILM7 DEX-LN3-006 DE51-LZ3-007-V4 DEX-LM3-008DV51-340-3K0 3 7.8 10 PKM0-16 DILM7 DEX-LN3-010 DE51-LZ3-011-V4 DEX-LM3-008DV51-340-4K0 4 8.6 11 PKM0-16 DILM7 DEX-LN3-010 DE51-LZ3-011-V4 DEX-LM3-011DV51-340-5K5 5.5 13 16.5 PKM0-20 DILM7 DEX-LN3-016 DE51-LZ3-020-V4 DEX-LM3-016DV51-340-7K5 7.5 16 20 PKM0-25 DILM17 DEX-LN3-025 DE51-LZ3-020-V4 DEX-LM3-016

Notes: 1)Mains chokes reduce the line currents by up to 30 % and extend the frequency inverters’ lifespan.2)No device assigned yet.3)Where single-phase frequency inverters are used on mains without mains choke (for example with reactive-power compensation equipment or UPS), current peaks can occur when the mains contactor is switched on, and these can cause the FAZ-B… to trip prematurely. Remedy: fit a mains reactor upstream or use a FAZ-C…Line protection with FAZ, PKM or PKZM (PKZM0 can be used instead of PKM0) a section 8 or 16DIL mains contactors a section 5Main chokes DEX-LN… a page 15/36Motor chokes DEX-LM3-… a page 15/37SFB400/… sine-wave filters please enquire

DV51

Page 14: Kapitel 15 G Online

15/14Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

EngineeringConnection example

Block diagram DV51

In their default configuration, the DV51 vector frequency inverters can be used at their assigned supply voltage and motor rating (four-pole, three-phase asynchronous motor) without any parameter changes. Their acceleration and deceleration times are set to 15 seconds. The control signal inputs and outputs have the following assigned functions:Terminal 1: FWD = Clockwise rotating field enable (Forward)Terminal 2: REV = Anticlockwise rotating field enable (Reverse)Terminal 3: FF1 = Fixed frequency 1Terminal 4: FF2 = Fixed frequency 2

Terminal 5: RST = Reset, can be configured as thermistor input with parameter C005.

Terminal 6: 2CH = Second parameter setTerminal 11: FA1 = Frequency arrival, type 1 (output frequency actual value

= reference input)Terminal 12: RUN = Running Terminals K11-K12:

Relay, fault signal (K11-K14 ready for operation)

Through optional keypad DEX-KEY-..., all parameters and functions can be adapted to the application.

5 L

i

* 0 V

+10

V 0 V

PEWVU

M3 ~

K11K12 K14

e

AM H O OI L 12 11

0...1

0 V

RUN

FA1

4...2

0 m

A

0...1

0 V

–+

–+

L+

BR

DC–

DC+

RBr

PEL3L2L1

3

1

PENL

2CH

FF2

FF1

REV

FWD

3 2 16 4 P24

+24 V

CM2RJ 45

ModBus

RST

* PNU C005 = 19 (PTC)

DV51

Page 15: Kapitel 15 G Online

15/15

http://catalog.moeller.net Moeller HPL0211-2007/2008

EngineeringConnection example

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Vector frequency inverters DV51 with DEV51–NET–TC module (RS 485 T adapter)

Actuation

Wiring

Q11

S2

Q1

S1

Q11

Hostcomputer

M1 M2 Mn

RBUS

6

5

1 2 32

POWEROPE

OFF

RBUS1 2ALARM

RUN

6 56 5

POWEROPE

OFF

RBUS1 2ALARM

RUN

6 56 5

POWEROPE

OFF

21RBUS

ALARMRUN

6 56 5

OPERBUS

OFF

1 2 OPERBUS

OFF

1 2

OPERBUS

OFF

1 2

SN

SP

RBUS

Host computer

3 h 400 V, 50/60 Hz

T1

L1 L2 L3 PE

L1L2L3PE

Q11

Q1

L1 L2 L3

K1 PE

DC+ DC–L+ U V W PE 1 P24

PES

PES

PE

PES

PES

MM1

X1

3 ~

PEIII

e

FWD

BR

EnableHost computer

DV51

Page 16: Kapitel 15 G Online

15/16Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

System overviewFrequency inverters

COPY

POWER

RUNPRG

REVFWD

ALARM

READCOPY

ENTERPRG

MNT

RMT

1A

C

D

TM2

TM12

8 ABD

F

C

E021

35

7 9

4

6

SEQ

CMB

CMB

B

4

6

5

3

2

Base units

Frequency inverters 1DF6-340-...Mains: 400 V 3-phaseMotor rating from 11 to 132 kW (400 V)a page 15/18

System accessories

Keypads 5External LCD keypad with/without memory functiona page 15/33

Mounting framesFor external LCD keypada page 15/33

Accessories

Radio interference suppression filter 2a page 15/23Line reactors 3a page 15/36Motor chokes 2a page 15/37

Braking resistor 4Enclosed (IP 20) high-capacity resistors with temperature switch, for connecting to the braking transistora page 15/37Connection cable for external display and control unitsa page 15/33

Communication modules 6PROFIBUS DP interfaceEncoder interfacing assemblya page 15/34

DF6

Page 17: Kapitel 15 G Online

15/17

http://catalog.moeller.net Moeller HPL0211-2007/2008

DescriptionFrequency inverter

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

The DF6 frequency inverters provide economic speed control of three-phase motors in standard applications with square-law load characteristics (pumps, fans).The assigned performance range for four-pole three-phase asynchronous motors ranges from 11 kW to 132 kW at 400 V.The DF6 units can be used as stand-alone drives or incorporated in automation systems. Their U/f(voltage/frequency) characteristic control allows their use in a broad range of applications in pump, fan, heating and air conditioning systems as well as all areas of process engineering with flow control.

• Compact construction• Plug-in keypad (external installation possible) with four-character seven-

segment display, six function keys and a setpoint value potentiometer• RS 485 and RS 422 serial interface• Six digital inputs (24 V DC)• 3 analog inputs (0 to +10 V, g10 V, 4 to 20 mA)• Three relays (a changeover contact, two make contacts: 24 V DC/230 V AC)• Thermistor input• Bus interface (PROFIBUS DP) can be integrated.• Global standards conforming to CE, UL, cUL, CSA and cTick

Note:The DF6-340-11K and DF6-340-15K frequency inverters have an integrated braking chopper and allow direct connection to the braking resistors DE4-BR1-…. For more than 15 kW the braking device DE4-BU4-1 is necessary for actuating the braking resistors.

Comprehensive protective functions guarantee safe operation and protect frequency inverters and motors:

• Overcurrent, earth fault• Overload, electronic motor protection• Overtemperature• Overvoltage, undervoltage• Phase failure

Two parameter sets with a wide range of functions:• PID controller• Automatic energy saving mode• Motor synchronization and flying restart circuit• User macro storage• Automatic restart after a power failure• Electronic motor potentiometer function• 16 fixed frequencies• Min./max. frequency limitation

• Each DF6 vector frequency inverter is supplied with installation instructions and a CD.

• The AWA contains a short description with illustrations and information about correct handling, installation and electrical connection of the device. The information supplied is printed in seven languages (English, Chinese, French, German, Italian, Russian, and Spanish).

• The CD contains a detailed manual (at least English, German) and configuration software with help text.

• Documentation and parameterization software are also available for download from the Internet:www.moeller.net/support

Note:The software on the CD can be run on PCs with the current Windows operating systems (from 98 to XP). For connecting a PC (RS 232) to a DF6 frequency inverter (RS 422), you will need the DEX-CBL-2M0-PC connection cable.

Application

Features

Function

Documentation

DF6

Page 18: Kapitel 15 G Online

15/18Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

OrderingDF6 frequency inverter

Rated voltage Max. rated operational current

Rated power for motors

Part no.Article no.

Pricesee price list

Std. pack

Ue Ie at 400 V 3-phase AC

V A P

kW

Frequency inverters 11 … 132 kW at 400 V342 – 528 V g 0 % 3-phase AC

22 11 DF6-340-11K231384

1 off

29 15 DF6-340-15K231385

37 18.5 DF6-340-18K5231386

43 22 DF6-340-22K231387

57 30 DF6-340-30K231388

70 37 DF6-340-37K231389

85 45 DF6-340-45K231390

105 55 DF6-340-55K231391

135 75 DF6-340-75K231392

160 90 DF6-340-90K231393

195 110 DF6-340-110K231394

230 132 DF6-340-132K231395

Notes Rated operational current with a switching frequency of 5 kHz and an ambient temperature of +40 °C.

DF6

Page 19: Kapitel 15 G Online

15/19

http://catalog.moeller.net Moeller HPL0211-2007/2008

EngineeringAssigned switching and protective elements

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Motor Frequency inverters Power supply Motor connection

Assigned motor rating

Rated operational current

Mains current

Without mains reactor or mains filter

Short-circuit and line protection fuse 4)

Mains contactor

Line reactor 1) Radio interference suppression filter

Motor reactor

P

kWIeA

INA

Frequency inverter DF6Three-phase power supply (400 V AC)DF6-340-11K 11 22 24 PKM0-25 2) DILM17 DEX-LN3-025 DE6-LZ3-032-V4 DEX-LM3-035DF6-340-15K 15 29 32 PKZM4-40 DILM17 DEX-LN3-040 DE6-LZ3-032-V4 DEX-LM3-035DF6-340-18K5 18.5 37 41 PKZM4-50 DILM17 DEX-LN3-040 DE6-LZ3-064-V4 DEX-LM3-050DF6-340-22K 22 43 47 PKZM4-50 DILM25 DEX-LN3-050 DE6-LZ3-064-V4 DEX-LM3-050DF6-340-30K 30 57 63 PKZM4-63 DILM40 DEX-LN3-060 DE6-LZ3-064-V4 DEX-LM3-063DF6-340-37K 37 70 77 NZM...1-S80 2) DILM50 DEX-LN3-080 DE6-LZ3-080-V4 DEX-LM3-080DF6-340-45K 45 85 94 NZM...1-S100 2) DILM65 DEX-LN3-100 DE6-LZ3-115-V4 DEX-LM3-100DF6-340-55K 55 105 116 NZM...1-S125 2) DILM80 DEX-LN3-120 DE6-LZ3-115-V4 DEX-LM3-150DF6-340-75K 75 135 149 NZM...1-S160 2) DILM115 DEX-LN3-160 DE6-LZ3-150-V4 DEX-LM3-150DF6-340-90K 90 160 176 NZM...2-S200 2) DILM150 DEX-LN3-1605) DE6-LZ3-220-V4 DEX-LM3-180DF6-340-110K 110 195 215 NZM...3-ME220 3) DILM185 DEX-LN3-200 DE6-LZ3-220-V4 DEX-LM3-220DF6-340-132K 132 230 253 NZM...3-ME350 3) DILM185 DEX-LN3-250 DE6-LZ3-260-V4 DEX-LM3-260

Notes 1) Mains chokes reduce the harmonic currents by up to 30 % and extend the frequency inverters’ lifespan.2) Short-circuit protection for mounting in control panel (no overload release required).3) Applications without electronic overload release: set Ir = infinite.4) Switching capacity (kA) according to power supply rating.5) At continuous, 100 percent motor load, the DEX-LN3-200 must be used here.

Line protection through NZM a section 10Line protection through PKZ a section 8Mains contactors DIL a section 5 Line reactors DEX-LN-… a page 15/36

DF6

Page 20: Kapitel 15 G Online

15/20Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

EngineeringConnection example

Block diagram DF6

In their default configuration, the DF6 frequency inverters can be used at their assigned supply voltage and motor rating (four-pole, three-phase asynchronous motor) without any parameter changes. Their acceleration and deceleration times are set to 30 seconds. The control signal inputs and outputs have the following assigned functions:

Terminal 1: RST = ResetTerminal 2: AT = change over to analog input OITerminal 3: FF2 = Fixed frequency 2Terminal 4: FF1 = Fixed frequency 1Terminal 5: REV = Anticlockwise rotating field

enable (Reverse) Terminal FW: FWD = Clockwise rotating field

enable (Forward)Terminal FM: Output frequency (PWM signal)Terminal AMI: Output frequency (analog signal

4...20 mA)Terminal AM: Output frequency (analog signal

0...10 V)Terminal 11: FA1 = frequency reaches set pointTerminals K11-K12: Relay, fault signal (K11-K14 ready

for operation)Terminal K23-K24: Rela, FA1, reference frequency

reachedTerminal K33-K34: Relay, RUN, in operationNote:Terminal BR*: Brake resistor, for DF6-320-11K,

DF6-340-11K and DF6-340-15K onlyThrough the built-in keypad, all parameters and functions can be adapted to the application.

PEW

VU

M 3 ~

K11

K12

K14

e

PLC

CM1

FMAM

IH

OO

IL

O2

AMTH

K23

K34

K24

K33

–+

L+ BR*

DC–

DC+

R Br

PEL3

L2L13 AC

400

V, 5

0/60

Hz

RST

AT

FF2

FF1

REV

34

51

2FW

P24

+24

V

FWD

K1K2

K3

RJ 4

5RS

422

SN RP SN SP

RS 4

85

– +

i

PTC

10 V (PWM)

4...20 mA

–10 V...+10 V

0...10 V

+10 V

0 V

0...+10 V

4...20 mA

DF6

Page 21: Kapitel 15 G Online

15/21

http://catalog.moeller.net Moeller HPL0211-2007/2008

System overviewVector frequency inverters

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

COPY

POWER

RUNPRG

REVFWD

ALARM

READCOPY

ENTERPRG

MNT

RMT

1A

C

D

TM2

TM12

8 ABD

F

C

E021

35

7 9

4

6

SEQ

CMB

CMB

B

4

6

5

3

2

Base units

Vector frequency inverters 1Mains: 400 V 3-phaseMotor ratings from 0.75 to 132 kW (400 V)a page 15/23

System accessories

Keypads 5External LCD keypad with memory functionConnection cable for external display and control units

a page 15/33

Mounting framesFor external LCD keypada page 15/33

Accessories

Radio interference suppression filter 2a page 15/35

Line reactors 3a page 15/36Motor chokes 3a page 15/37

Braking resistor 4Enclosed (IP 20) high-capacity resistors with temperature switch, for connecting to the braking transistora page 15/37

Communication modules 6PROFIBUS DP interfaceEncoder interfacing assemblya page 15/34

DV6

Page 22: Kapitel 15 G Online

15/22Fr

eque

ncy

inve

rter

s Ve

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

DescriptionVector frequency inverters

The DV6 is the most powerful vector control frequency inverter of its class, with more than 200 % starting torque and virtually full static torque without feedback (sensorless). It guarantees the highest levels of smooth operation and is particularly suited to highly-dynamic applications in the packaging, printing and textile industries, for machine tools, and in material handling with elevator systems and hoists.The DV6 can be used as a stand-alone drive or incorporated in complex automation systems.The assigned performance range for four-pole three-phase asynchronous motors ranges from 0.75 kW to 132 kW at 400 V.

• Sensorless Vector Control (closed/open loop)• Motor autotuning (online/offline)• Built-in braking transistor (DV6-340-075 to DV6-340-11K)• 32-bit processor• Plug-in keypad (external installation possible) with four-character seven-

segment display, six function keys and a setpoint value potentiometer• RS 485 and RS 422 serial interface• Nine digital inputs (24 V DC)• 3 analog inputs (0 to +10 V, g10 V, 4 to 20 mA)• Thermistor input• Five digital outputs (24 V DC)• Two analog outputs (0/+10 V, 4 – 20 mA)• Relay (changeover contact: 24 V DC/230 V AC)• Bus interface (PROFIBUS DP) can be integrated.• Global standards conforming to CE, UL, cUL, CSA and cTick

Note:The DV6-340-075 to DV6-340-15K frequency inverters have an integrated braking chopper and allow direct connection to the braking resistors DE4-BR1-…. Over 15 KW the DE4-BU4-1 braking unit is necessary to actuate the braking resistors.

Comprehensive protective functions guarantee safe operation and protect frequency inverters and motors:

• Overcurrent, earth fault• Overload, electronic motor protection• Overtemperature• Overvoltage, undervoltage• Phase failure• Configurable delay with emergency-off and voltage failure

Three parameter sets with a wide range of functions:• P/PI controller and PID closed-loop controller• Automatic voltage regulation• Motor synchronization and flying restart circuit• Rapid stop function• User macro storage• Electronic motor potentiometer function• 16 fixed frequencies (bit/binary)• Min./max. frequency limitation

• Each vector frequency inverter DV6 is supplied with an installation instruction (AWA) and a CD.

• The AWA contains a short description with illustrations and information about correct handling, installation and electrical connection of the device. The information supplied is printed in seven languages (English, Chinese, French, German, Italian, Russian, and Spanish).

• The CD contains a detailed manual and configuration software with help text. • Documentation and parameterisation software is also available for download

from the Internet:www.moeller.net/support

Note:The software on the CD can be run on PCs with the current Windows operating systems (from 98 to XP). For connecting a PC (RS 232) to a DV6 frequency inverter (RS 422), you will need the DEX-CBL-2M0-PC connection cable.

Application

Features

Function

Documentation

Page 23: Kapitel 15 G Online

15/23

http://catalog.moeller.net Moeller HPL0211-2007/2008

OrderingVector frequency inverter

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Rated voltage Max. rated operational current

Rated power for motors

Part no.Article no.

Pricesee price list

Std. pack

Ue Ie at 400 V 3-phase AC

V A P

kW

Vector frequency inverter 0.75 kW to 132 kW at 400 V342 – 528 V g 0 % 3-phase AC

2.5 0.75 DV6-340-075231396

1 off

3.8 1.5 DV6-340-1K5231397

5.3 2.2 DV6-340-2K2231398

8.6 4 DV6-340-4K0231399

12 5.5 DV6-340-5K5231400

16 7.5 DV6-340-7K5231401

23 11 DV6-340-11K231402

32 15 DV6-340-15K231403

38 18.5 DV6-340-18K5231404

48 22 DV6-340-22K231405

58 30 DV6-340-30K231406

75 37 DV6-340-37K231407

90 45 DV6-340-45K231408

110 55 DV6-340-55K231409

149 75 DV6-340-75K231410

176 90 DV6-340-90K231411

217 110 DV6-340-110K231412

260 132 DV6-340-132K231413

Notes 1) Rated operational current at an operating frequency of 5 kHz and an ambient temperature of +40°C.

DV6

Page 24: Kapitel 15 G Online

15/24Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

EngineeringAssigned switching and protective elements

Motor Frequency inverters Power supply Mains contactor

Mains reactor1) Radio interference suppression filter

Motor reactor

Assigned motor rating

Rated operational current

Mains current

Without mains reactor or mains filter

Short-circuit and line protection 4)

P

kWIeA

INA

Frequency inverters DV6Three-phase power supply (400 V AC)DV6-340-075 0.75 2.5 2.8 PKM0-6,3 2) DILM7 DEX-LN3-004 DE6-LZ3-013-V4 DEX-LM3-005DV6-340-1K5 1.5 3.8 4.2 PKM0-6,3 2) DILM7 DEX-LN3-004 DE6-LZ3-013-V4 DEX-LM3-005DV6-340-2K2 2.2 5.3 5.8 PKM0-10 2) DILM7 DEX-LN3-006 DE6-LZ3-013-V4 DEX-LM3-008DV6-340-4K0 4 8.6 9.5 PKM0-10 2) DILM7 DEX-LN3-010 DE6-LZ3-013-V4 DEX-LM3-011DV6-340-5K5 5.5 12 13 PKM0-16 2) DILM7 DEX-LN3-016 DE6-LZ3-013-V4 DEX-LM3-016DV6-340-7K5 7.5 16 18 PKM0-20 2) DILM7 DEX-LN3-025 DE6-LZ3-032-V4 DEX-LM3-016DV6-340-11K 11 23 25 PKZM4-40 DILM17 DEX-LN3-025 DE6-LZ3-032-V4 DEX-LM3-035DV6-340-15K 15 32 35 PKZM4-40 DILM17 DEX-LN3-040 DE6-LZ3-064-V4 DEX-LM3-035DV6-340-18K5 18.5 38 42 PKZM4-50 DILM25 DEX-LN3-040 DE6-LZ3-064-V4 DEX-LM3-035DV6-340-22K 22 48 53 PKZM4-58 DILM40 DEX-LN3-050 DE6-LZ3-064-V4 DEX-LM3-050DV6-340-30K 30 58 63 NZM...1-S80 2) DILM40 DEX-LN3-060 DE6-LZ3-080-V4 DEX-LM3-063DV6-340-37K 37 75 83 NZM...1-S100 2) DILM50 DEX-LN3-080 DE6-LZ3-115-V4 DEX-LM3-080DV6-340-45K 45 90 99 NZM...1-S100 2) DILM65 DEX-LN3-100 DE6-LZ3-115-V4 DEX-LM3-100DV6-340-55K 55 110 121 NZM...1-S125 2) DILM95 DEX-LN3-120 DE6-LZ3-125-V4 DEX-LM3-150DV6-340-75K 75 149 164 NZM...2-S200 2)5) DILM115 DEX-LN3-160 DE6-LZ3-220-V4 DEX-LM3-150DV6-340-90K 90 176 194 NZM...2-S200 2) DILM150 DEX-LN3-200 DE6-LZ3-220-V4 DEX-LM3-180DV6-340-110K 110 217 239 NZM...3-ME350 3) DILM185 DEX-LN3-250 DE6-LZ3-260-V4 DEX-LM3-220DV6-340-132K 132 260 286 NZM...3-ME350 3) DILM185 DEX-LN3-300 DE6-LZ3-260-V4 DEX-LM3-260

Notes 1) Mains chokes reduce the harmonic currents by up to 30 % and extend the frequency inverters’ lifespan. 2) Short-circuit protection for mounting in control panel (no overload release required).3) Applications without electronic overload release: set Ir = infinite.

4) Switching capacity (kA) according to power supply rating.5) When using with DEX-LN3-160 mains choke, you can use NZM...2-S160.

Line protection through NZM a section 10Line protection through PKZ a section 8Mains contactors DIL a section 5 Line reactors DEX-LN-… a page 15/36

DV6

Page 25: Kapitel 15 G Online

15/25

http://catalog.moeller.net Moeller HPL0211-2007/2008

EngineeringConnection example

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Block diagram DV6

In their default configuration, the DV6 vector frequency inverters can be used at their assigned supply voltage and motor rating (four-pole, three-phase asynchronous motor) without any parameter changes. Their acceleration and deceleration times are set to 30 seconds. The control signal inputs and outputs have the following assigned functions:

Terminal 1: RST = ResetTerminal 2: AT = change over to analog input

OITerminal 3: JOG = inching dutyTerminal 4: FRS = free run stop of motor

(controller inhibit)Terminal 5: 2CH = Second parameter setTerminal 6: FF2 = Fixed frequency 2Terminal 7: FF1 = Fixed frequency 1Terminal 8: REV = Anticlockwise rotating field

enable (Reverse) Terminal FW: FWD = Clockwise rotating field

enable (Forward)Terminal FM: Output frequency (PWM signal)Terminal AMI: Output frequency (analog signal

4...20 mA)Terminal AM: Output frequency (analog signal

0...10 V)Terminal 11: FA1 = frequency reaches set pointTerminal 12: RUN = RunningTerminal 13: OL = overload signalTerminal 14: QTQ = torque reached (exceeded)Terminal 15: IP = mains failure; immediate stop

signalTerminals K11-K12: Relay, fault signal (K11-K14 ready

for operation)Note:Terminal BR*: Brake resistor; for DV6-320-11K

and DV6-340-075K to DV6-340-15K only

Through the built-in keypad, all parameters and functions can be adapted to the application.

PEW

VU

M 3 ~

K11

K12

K14

e

L+ BR*

DC–

DC+

R Br

PEL3

L2L1

ROTO

3

K1

J51

RST

AT

JOG

FRS

2CH

34

51

26

1314

1511

12

FF2

FF1

REV

78

FWFWD

PLC

CM1

FMAM

IH

OO

IL

O2

AMTH

CM2

–+

P24

+24

V

RJ 4

5RS

422

SN RP SN SP

RS 4

85

– +

i

PTC

10 V (PWM)

4...20 mA

–10 V...+10 V

0...10 V

+10 V

0 V

0...+10 V

4...20 mA

FA1

RUN

OL

QTQ

IP+

24 V

P24

DV6

Page 26: Kapitel 15 G Online

15/26Fr

eque

ncy

inve

rter

s Ve

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

DescriptionKeypads

• Operating unit with set point potentiometer (valid for DEX-KEY 6 only)• Remote keypad for the DF51, DF6, DV51 and DV6 frequency inverters.• Instead of the LED display, these keypads can be slotted into the DV51

frequency inverters or, with adapter DEV51-MNT-K60, snapped onto interface modules DE51-NET-CAN and DE51-NET-DP.

Note:For remote flush mounting in an enclosure (e.g. control panel door), mounting frame DEX-MNT-K6 and connection cable DEX-CBL-...-ICS or DNW-PC... are required.

• Four-digit digital display assembly• 7 LED function messages (applies to DEX-KEY 6)• 6 LED function messages (applies to DEX-KEY 61)• START/STOP and 4 configuration keys• Set point potentiometer (applies to DEX-KEY 6)

The LCD keypad allows all parameters of the DF51, DF6, DV51 and DV6 frequency inverters and to be set as well as their operation through the START/STOP buttons. The reference input can be made through the Up/Down buttons (motor potentiometer function) and through an analog setpoint potentiometer.

Installation instructions are supplied with each keypad. For notes about parameterisation, see the frequency inverter’s manual. They can be found on the CD supplied with every frequency inverter. The documentation is also available on the Internet at www.moeller.net/support.

Optional keypad with non-volatile configuration memory for the DF51, DV51, DF6 and DV6 frequency inverters as well as the RA-SP speed control unit.DEX-KEY-10 can be mounted in a control panel enclosure or fitted instead of the standard keypad of the DF6 and DV6 frequency inverters.The frequency inverter is connected via the RJ 45 interface.

Note:The connectors must be connected and disconnected only under no-voltage conditions.For external mounting, a connection cable with RJ 45 plugs (DEX-CBL-...-ICS or DNW-PC respectively) is required.

• Two-line, background-lit LCD display• LED function messages• Plain text display, in one of six languages (English, French, German, Italian,

Portuguese, Spanish) with DF6 and DV6, and in English with DF51 and DV51.• START/STOP buttons and function keys for parameterisation• Degree of protection: operating side (front) IP 54, NEMA 12

With the DEX-KEY-10 keypad, all parameters can be edited. They can be saved and transferred to frequency inverters of the same type (copy function, non-volatile memory).Parameters, setpoint values and actual values are displayed in English on a single line with the DF51, DV51 and RA-SP frequency inverters. With the DF6 and DV6 devices, two display lines are used The languages can be selected.

Installation instructions are supplied with each keypad.For notes about parameterisation, see manual AWB8240-1416 on the CD supplied with every frequency inverter of the series DF51, DF6 and DV51, DV6.The documentation is also available on the Internet: www.moeller.net/support.

Part no. overview

DEX-KEY-6DEX-KEY-61

Application

Features

Functions

Documentation

Part no. overview

DEX-KEY-10External keypad with configuration memory

Application

Features

Function

Documentation

DEX-KEY6..., DEX-KEY-10

Page 27: Kapitel 15 G Online

15/27

http://catalog.moeller.net Moeller HPL0211-2007/2008

DescriptionAccessories

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Connection and extension of the system interface for frequency inverters DF51, DF6, DV51 and DV6, and speed control unit RA-SP.

Prefabricated for immediate use.

• The DEV51-NET-TC T-adapter doubles the RJ 45 connector of the DV51 (T piece). It is required to connect multiple DV51 frequency inverters as slaves to a system with the open RS 485 and Modbus RTU communication protocol.

• The connection cable allows the point-to-point connection of the RJ-45 slot.• Interface converter DEX-CLB-2MO-PC allows a direct point-to-point connection

of a PC with 9-pin RS232 (Sub-D) socket to the RJ-45 interface (RS 422/RS 485) of a DF51, DF6, DV51 or DV6 frequency inverter or on RA-SP.

• Adapter DEV51-MNT-K60 allows the installation and connection of keypad DEX-KEY-6… in combination with a fieldbus module DE51-NET-CAN or DE51-NET-DP and DV51 frequency inverters.

• Mounting frame DEX-MNT-K6 allows the seperate mounting of DEX-KEY-6 and DEX-KEY61 keypads in an enclosure (e.g. control panel door)

Adapter DV51-MNT-K60 and mounting frame DEX-MNT-K6 are supplied with all accessories required for application, such as self-adhesive rubber seals and connectors.

• Mounting frame and cover are purely mechanical components without separate functionality.

The mounting frame can be fitted as follows:• A: in a control panel door or enclosure with standard punching tool (square

67 x 67 mm)• B: Flush mounting in a water-resistant enclosure (IP 54, NEMA 4). Permissible

only with DEX-KEY-61 keypad without potentiometer.

Installation and mounting are described in the installation instructions of keypad DEX-KEY-6... They are described in the XSoft manual (AWB2700-1437GB). The documentation is contained on the CD supplied with each frequency inverter. The documentation is also available on the Internet: www.moeller.net/support

Part no. overview

DEV51-NET-TCT adapter for RS 485/Modbus connection

DEX-CBL-…-ICSDWN-PC-…Connecting cable with RS 45 plug

DEX-CBL-2M0-PCInterface converter with connection cable

Application

Features

Functions

Part no. overview

DEV51-MNT-K60Adapter for the operating unit DEX-KEY 6…

DEX-MNT-K6Mounting frame for the operating unit DEX-KEY 6…

Application

Features

Functions

Documentation

DEV51, DEX

Page 28: Kapitel 15 G Online

15/28Fr

eque

ncy

inve

rter

s Ve

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

DescriptionInterface cards

DE51-NET-… allows the connection of DF51 and DV51 series frequency inverters as slaves to systems with standardised field bus (CANopen, PROFIBUS-DP).On the DV51 the interface modules can be front-mounted; on the DF51, they are mounted separately in mounting frame DEX-MNT-NET. A prefabricated connecting cable (DEX-CBL... or DWN-PC...) is required to connect the DF51.

DE51-NET-CAN• Communications protocol: DS-301 V4.01• Device profile: DS-402 V2.0• Bus address: 1 to 127• Max. cable length: 5000 m• Data transfer rate: 10 kbit/s to 1 Mbit/s, depending on cable length and amplifier• Isolated interface• address and baud rate adjustable through DIP switches• Five status LEDs• Clip-on to DV51, remote connection to DF51 (connection cable DEX-CBL-…-ICS

required).

DE51-NET-DP• Network topology: PROFIBUS DP line (DIN 19245 part 1 and 3)• DRIVECOM profile drive control technology 20• Bus address: 1 to 127• max. cable length: 10 000 m• Data transfer rate: 93.7 kbit/s to 12 Mbit/s, depending on cable length and

amplifier• Isolated interface• address and baud rate adjustable through DIP switches• Five status LEDs• Clip-on to DV51, remote connection to DF51 (connection cable DEX-CBL-…-ICS

required).

Installation instructions are supplied with each module. Further documentation for this module is also available on the Internet at: www.moeller.net/support.

PRGENTER

I O

POWER

ALARM

Part no. overview

DE51-NET-DPInterface for connecting to PROFIBUS DP

DE51-NET-CANInterface for connecting to CANopen

DEX-MNT-NETMounting frame for the external arrangement of interface modules

Application

Features

Documentation

DE51-NET-DP, DE51-NET-CAN

Page 29: Kapitel 15 G Online

15/29

http://catalog.moeller.net Moeller HPL0211-2007/2008

DescriptionInterface cards

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

• Installation in slot 2 of DF6 or DV6 frequency inverter• Intelligent modules with their own processor and with potential isolation• RS 485 interface (9-pin, D-SUB socket)• Device address set with two rotary switches• Data transfer: 9.6 Kbit/s (at 1,200 m) to 12 Mbit/s (at 100 m) with automatic

baud rate detection• PROFIDrive profile, drive engineering version 2

Each PROFIBUS-DP module DE6-NET-DP comes with installation instructions (AWA 8240-1942). For notes about parameterizing these modules, see manual AWB8240-1418, which is contained on the CD supplied with each DF6 and DV6 series frequency inverter. The documentation is also available on the Internet: www.moeller.net/support

The DE6-IOM-ENC card can be used in conjunction with the DV6 vector frequency inverters and enables speed control of three-phase motors with a directly connected encoder.Further application features are:

• Synchro control and ratio control• Motor standstill recognition• Torque regulation

• Simply plugs into a slot in the DV6 frequency inverter

Note:The card must be fitted and pulled only under no-voltage conditions.• Parameterization via the DV6 frequency inverter’s menu.• Encoder connection via screw terminals.

• Output voltage (power supply) for the encoder: 5 V DC, 150 mA.• Max. number of input pulses: 65,000• Input: two TTL signals offset by 90° (5 V DC, RS 422 standard) with zero pulse

and inverted signals.

Installation instructions are supplied with each encoder module. The manual for the encoder card (AWB8240-1431) is contained on the CD supplied with every DV6 frequency inverter.The documentation is also available on the Internet: www.moeller.net/support

Part no. overview

DE6-NET-DPInterface for PROFIBUS DP networks

Application

Features

Documentation

Part no. overview

DE6-IOM-ENCEncoder card for DV6 frequency inverters

Application

Features

Function

Documentation

EAN

EBP

EBN

EZP

M

90˚

EZN

EAP

DE6-NET-DP, DE6-IOM-ENC

Page 30: Kapitel 15 G Online

15/30Fr

eque

ncy

inve

rter

s Ve

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

DescriptionMotor chokes

Mains chokes – also called commutating chokes – are connected in series on the mains input side of electronic equipment e.g. frequency inverters.

Mains chokes limit the inrush current and dampen current harmonics and any additional current peaks. By dampening the harmonic currents, the r.m.s value of the input current can be reduced by up to 30 %. In addition, they allow the often mandatory short-circuit voltage (k value) of about 4 % to the mains.Mains chokes extend components’ lifespan (rectifier diodes, DC link capacitors) on equipment with input-side DC link (frequency inverters, UPS).

The mains chokes are vacuum-impregnated for low-noise operation. They offer low-fatigue, magnetically and metallically neutral air-gap bypasses.Because of their flux distribution, the clearance to metal parts and neighbouring components must be at least 50 mm.

Motor chokes are used on the output of the frequency inverters in series with the motor.

Motor chokes reduce the slew rate of the output voltage (/ < 500 V/ms) as well as motor noise and heating.The use of motor chokes enables the permissible motor cable lengths to be extended up to 200 m.With parallel operation of several motors from the output of a frequency inverter the use of motor chokes is recommended. They reduce the higher capacitive reactive currents.

The motor chokes are vacuum-impregnated for low-noise operation. They offer low-fatigue, magnetically and metallically neutral air-gap bypasses.Because of their flux distribution, the clearance to metal parts and neighbouring components must be at least 50 mm.

Installation instructions are supplied with each choke. The documentation is also available on the Internet:www.moeller.net/support

Part no. overview

DEX-LN1...Mains chokes, single-phase

DEX-LN3...Mains chokes, three-phase

Application

Function

Features

Part no. overview

DEX-LM3...Motor chokes, three-phase

Application

Function

Features

Documentation

DEX-LN..., DEX-LM3...

Page 31: Kapitel 15 G Online

15/31

http://catalog.moeller.net Moeller HPL0211-2007/2008

DescriptionBrake units, brake resistances

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Braking units with assigned braking resistors are used for rapid braking of frequency-controlled three-phase drives.With its integrated synchronization, the DE4-BU4-1 allows several braking units to be operated in parallel, for example for large loads (lifting gear).

• Braking transistor with automatic control (adjustable response value)• Braking resistors (DE4-BR1...) are not supplied with the device. The lowest

permissible resistance is: 18 Ω• Synchronization for parallel operation of several DE4-BU... at high braking

power.• Continuous braking power up to 18 kW• Maximum braking power 30 kW, with 15 s make time and 150 s pause time

With short braking times, the frequency controlled motor operates in regenerative (oversynchronous) mode. In this mode, it feeds power into the frequency inverter’s DC link, which results in an increased DC bus voltage. If the voltage exceeds the permitted limit value, the frequency inverter control logic disables the frequency inverter’s power inverter and the motor coasts to a stop.If one or more braking units are connected in parallel to the internal DC link, the recovered energy can be diverted through the assigned braking resistors, where it is dissipated as heat.

Installation instructions are supplied with each braking unit. The documentation is also available on the Internet: www.moeller.net/support

An external braking resistor is required when braking large moments of inertia or when operating in extended regenerative mode. It converts the mechanical braking energy to heat.

The integral braking transistor of the frequency inverter automatically diverts energy to the connected braking resistor when the threshold value of the DC bus voltage is exceeded. This prevents overvoltages in the DC link, which would otherwise cause an “overvoltage” fault message and activate the pulse inhibitor of the frequency inverter. The drive coasts to a stop.

The resistors are built into a perforated sheet-metal enclosure and are fitted with an overtemperature protection switch (230 V, 1A, AC-1). The enclosure is made from galvanized perforated sheet metal, The enclosures are open at the bottom and fullfil protection IP20 only when mounted.By combining several resistances in series and/or parallel higher braking capacities can be obtained.The braking resistors can be directly connected to the brake chopper of the frequency inverter DV51, DF6-340-11K, DF6-340-15K, DV6-340-075…11K and the braking unit DE4-BU4-1.

Installation instructions are supplied with each braking unit. The documentation is also available on the Internet:www.moeller.net/support

Part no. overview

DE4-BU... braking unitBraking unit for controlling external braking resistors

Application

Features

Function

Documentation

Part no. overview

DE4-BR1…Braking resistors

Application

Function

Features

Documentation

2T1

T2

1

i

PE

RB

DE4-BU4-1, DE4-BR1...

Page 32: Kapitel 15 G Online

15/32Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

EngineeringConnection examples

a Keypad and bus connection in combination with frequency inverter DV51

b Bus connectionin combination with frequency inverter

c Side mounting of RFI filter

d Footprint application of RFI filter e Flush mounting of keypad in a control panel door

f Connection example: frequency inverter with braking unit and braking resistance

DE51-NET-CAN

DE51-NET-CAN

DV51

DV51-MNT-K60DEX-KEY-6

I O

HzA

RUN

POWERALARM

PRG

PRGENTER

A

RUN

PRG

PRGENTER

I O

POWER

ALARM

DEX-MNT-NET

DEX-CBL...DWN-PC...

DE51-NET...

DF51

A

RUN

PRG

Hz

PRGENTER

I O

POWER

ALARM

A

RUN

PRG

Hz

PRGENTER

I O

POWER

ALARM

DF6, DV6DF51, DV51

DEX-CBL...ICSDWN-PC...

DEX-MNT-K6

DEX-KEY-6...

DC+ +UGDC– –UG

DE4-BR1-...

DE4-BU4-1

DV6-340DF6-340

Page 33: Kapitel 15 G Online

15/33

http://catalog.moeller.net Moeller HPL0211-2007/2008

OrderingAccessories

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

For use with Part no.Article no.

Pricesee price list

Std. pack

KeypadsLCD keypad with potentiometer. Flush mounting in DV51 frequency inverters possible. For separate application, a connection cable (DEX-CBL-…ICS, DNW-PC…) is required.

DF51-…DF6-...DV51-...DV6-...

DEX-KEY-6289943

1 off

LCD keypad. Flush mounting in DV51 frequency inverters possible. For separate application, a connection cable (DEX-CBL-…ICS, DNW-PC…) is required.

DF51-…DF6-...DV51-...DV6-...

DEX-KEY-61289944

1 off

Mounting frame for DEX-KEY-6… LCD keypadMounting frame for DEX-KEY-6… LCD keypad DEX-KEY-6… DEX-MNT-K6

2899451 off

DEX-KEY-10LCD keypad with non-volatile memory. Flush mounting in DF6 and DV6 frequency inverters possible. For remote operation, a connection cable (DEX-CBL-…ICS, DNW-PC...) is required.

DF51-...DF6-...DV51-...DV6-...RA-SP

DEX-KEY-10231421

1 off

Interface modulesT adapter DEV51-NET-TC

T adapter. Flush mounting in DV51 frequency inverters possible. Interface (T connector) with RJ45 sockets for the built-in RS 485/Modbus RTU interface.

DV51-… DEV51-NET-TC289948

1 off

Connection cablesInterface converter RS332/RJ45 with connection cable (2 m) with RJ45 plug and 9-pin Sub-D plug

DF51-...DF6-...DV51-...DV6-...RA-SP

DEX-CBL-2M0-PC233184

1 off

Connection cablesConnection cable (1.0 m) with RJ-45 plugs DEX-KEY-10

DEX-KEY-6DEX-KEY-61DEV51-NET-TCDE51-NET-DPDE51-NET-CAN

DEX-CBL-1M0-ICS232375

1 off

Connection cable (3.0 m) with RJ-45 plugs DEX-CBL-3M0-ICS232376

1 off

Connection cable (0.5 m) with RJ 45 plug DNW-PC/0050/RJ45/RJ45/5E/CSUTP/GR237146

10 off

Connection cable (1.0 m) with RJ 45 plug DNW-PC/0100/RJ45/RJ45/5E/CSUTP/GR237147

10 off

Connection cable (1.0 m) with RJ 45 plug DNW-PC/0300/RJ45/RJ45/5E/CSUTP/GR237154

1 off

HzA

RUN

POWERALARM

PRGI O

PRGENTER

HzA

RUN

POWERALARM

PRGI O

PRGENTER

RMT

ALARM

FWDREV

PRGPOWERRUN

READ COPY

MNT PRG ENTER

POWERALARM

RUN

1 2

OFF

OPERBUS

DEX, DEV

Page 34: Kapitel 15 G Online

15/34Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

OrderingInterface modules

For use with Part no.Article no.

Pricesee price list

Std. pack

Interface modulesCANopen interface module DE51-NET-CAN

CANopen interface for DV51 frequency inverters and for external connection for DF51 (connection cable DEX-CBL-…ICS or DNW-PC… required)

DF51-…DV51-...

DE51-NET-CAN289947

1 off

PROFIBUS-DP interface card DE51-NET-DPPROFIBUS DP interface for DV51 frequency inverters and for external connection for DF51 (connection cable DEX-CBL-…ICS required)

DF51-…DV51-...

DE51-NET-DP289946

1 off

DE6-NET-DP PROFIBUS DP interfacing modulePROFIBUS-DP interfacing for DF6 frequency inverter and DV6 vector frequency inverter. This card is installed in the devices.

DF6-.../DV6-... DE6-NET-DP232369

1 off

DE6-IOM-ENC encoder interfacing moduleEncoder interface module for speed control and synchronous speed control. The module is installed in vector frequency inverter DV6.

DV6-... DE6-IOM-ENC232365

1 off

Mounting framesMounting frame with connection cable for the external arrangement of interface modules DE51-NET-CAN and DE51-NET-DP

DF51...DV51...

DEX-MNT-NET106265

1 off

Mounting frame for LCD keypads DEX-KEY-6… on interface modules DE51-NET-CAN and DE51-NET-DP for vector frequency inverters DV51…

D51-NET… DEV51-MNT-K60292382

1 off

DE51-NET-…, DE6-…

Page 35: Kapitel 15 G Online

15/35

http://catalog.moeller.net Moeller HPL0211-2007/2008

OrderingRadio interference suppression filter

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Rated voltage Assigned frequency inverter Part no.Article no.

Pricesee price list

Std. pack Notes

Ue DF DV

V

Radio interference suppression filter1 AC 250 V DF51-322-025

DF51-322-037DF51-322-055

DV51-322-025DV51-322-037DV51-322-055

DE51-LZ1-007-V2289960

1 off The radio interference suppression filters can be side- or footprint mounted to the frequency inverter.

1 AC 250 V DF51-322-075DF51-322-1K1

DV51-322-075DV51-322-1K1

DE51-LZ1-012-V2289961

1 AC 250 V DF51-322-1K5DF51-322-2K2

DV51-322-1K5DV51-322-2K2

DE51-LZ1-024-V2289962

3 AC 480 V DF51-340-037DF51-340-075DF51-340-1K5DF51-340-2K2

DV51-340-037DV51-340-075DV51-340-1K5DV51-340-2K2

DE51-LZ3-007-V4289963

3 AC 480 V DF51-340-3K0DF51-340-4K0

DV51-340-3K0DV51-340-4K0

DE51-LZ3-011-V4289964

3 AC 480 V DF51-320-4K0DF51-340-5K5DF51-340-7K5

DV51-320-4K0DV51-340-5K5DV51-340-7K5

DE51-LZ3-020-V4289965

3 AC 342…528 V g 0 % DV6-340-075DV6-340-1K5DV6-340-2K2DV6-340-4K0DV6-340-5K5

DE6-LZ3-013-V4232358

3 AC 342…528 V g 0 % DF6-340-11KDF6-340-15K

DE6-LZ3-032-V4232359

3 AC 342…528 V g 0 % DF6-340-18K5DF6-340-22KDF6-340-30K

DV6-340-15KDV6-340-18K5DV6-340-22K

DE6-LZ3-064-V4232360

3 AC 342…528 V g 0 % DF6-340-37K DV6-340-30K DE6-LZ3-080-V4232361

Only side mounting beside frequency inverter possible.3 AC 342…528 V g 0 % DF6-340-45K

DF6-340-55KDV6-340-37KDV6-340-45K

DE6-LZ3-115-V4232362

3 AC 342…528 V g 0 % DV6-340-55K DE6-LZ3-125-V4232363

3 AC 342…528 V g 0 % DF6-340-75K DE6-LZ3-150-V4233181

3 AC 342…528 V g 0 % DF6-340-90KDF6-340-110K

DV6-340-75KDV6-340-90K

DE6-LZ3-220-V4233182

3 AC 342…528 V g 0 % DF6-340-132K DV6-340-110KDV6-340-132K

DE6-LZ3-260-V4233183

DE... - LZ...

Page 36: Kapitel 15 G Online

15/36Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

OrderingMains chokes

Inductance Rated current Maximum power loss

Part no.Article no.

Pricesee price list

Std. pack Notes

L I Pv

mH A W

Single-phase mains chokes

• Max. permissible mains voltage 260 V + 0 %5.05 5.8 9 DEX-LN1-006

2694901 off Mains chokes reduce

the harmonic currents by up to 30 % and extend the lifespan of the frequency inverter.

3.41 8.6 11 DEX-LN1-009269495

2.25 13 12 DEX-LN1-013269496

1.63 18 17 DEX-LN1-018269497

1.22 24 20 DEX-LN1-024269498

Three-phase mains chokes

• Max. permissible mains voltage 550 V + 0 %7.51 3.9 17 DEX-LN3-004

2695001 off Mains chokes reduce

the harmonic currents by up to 30 % and extend the lifespan of the frequency inverter.

4.9 6 19 DEX-LN3-006269501

2.94 10 33 DEX-LN3-010269502

1.84 16 44 DEX-LN3-016269503

1.18 25 57 DEX-LN3-025269504

0.46 40 59 DEX-LN3-040269505

0.37 50 58 DEX-LN3-050269506

0.31 60 60 DEX-LN3-060269507

0.23 80 86 DEX-LN3-080269508

0.18 100 101 DEX-LN3-100269509

0.15 120 100 DEX-LN3-120269510

0.11 160 140 DEX-LN3-160269511

0.09 200 154 DEX-LN3-200269512

0.07 250 155 DEX-LN3-250269513

0.06 300 169 DEX-LN3-300269514

DEX-LN...

Page 37: Kapitel 15 G Online

15/37

http://catalog.moeller.net Moeller HPL0211-2007/2008

OrderingMotor chokes, brake units, brake resistances

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Inductance Rated current

max. heat dissipation at 12 kHz

Part no.Article no.

Pricesee price list

Std. pack Notes

L I Pv

mH A W

Three-phase motor chokes• Max. permissible mains voltage 750 V + 0 %

2 5 24 DEX-LM3-005269538

1 off Motor reactors reduce the du/dt value of the output voltage and therefore the motor noise and heating.Motor chokes have larger dimension than mains chokes with the same rated current.

4.1 8 54 DEX-LM3-008269539

3 11 71 DEX-LM3-011269541

1.5 16 78 DEX-LM3-016269542

1 35 116 DEX-LM3-035269543

0.6 50 168 DEX-LM3-050269544

0.5 63 193 DEX-LM3-063269545

0.5 80 206 DEX-LM3-080269546

0.45 100 294 DEX-LM3-100269547

0.35 150 424 DEX-LM3-150269548

0.3 180 439 DEX-LM3-180269549

0.2 220 517 DEX-LM3-220269560

0.15 260 520 DEX-LM3-260269561

Frequency inverter Braking unit Part no.Article no.

Pricesee price list

Std. pack

Mains supply voltage (50/60 Hz)

Minimum braking resistance

Maximum brake current

Continuous braking rating at ULN

Maximum braking rating

ULN Rmin I at 230 V at 400 V PmaxV O A DC P P kW

W W

Braking unit DE4-BU4-1

for more rapid braking of frequency-controlled three-phase drivessetting of the braking rating via external braking resistance possible via:exchange of the existing braking resistance, series or parallel connection of a further resistor

400/460 18 (external) 25 9000 18000 30 DE4-BU4-1085035

1 off

Notes The rating applies for an operating time of 15 s and an off period of 150 s.

Impedance Rated braking power

Peak braking power

Part no.Article no.

Pricesee price list

Std. pack Notes

R Pnom PPeak

O W W

DE4-BR1... braking resistors82 245 1700 DE4-BR1-082-245

2194851 off The braking resistors are designed for a load

cycle of:• max. 15 s braking at peak braking power• min. 150 s recovery time after brakingThe resistors are built into a perforated sheet-metal enclosure and are fitted with an overtemperature protection switch (230 V, 1A, AC-1).Enclosure: galvanized perforated brass, open bottom.Degree of protection IP20 is achieved only in installed state.

100 200 1400 DE4-BR1-100-200219489

200 100 700 DE4-BR1-200-100219490

240 285 2000 DE4-BR1-240-285219492

370 215 1500 DE4-BR1-370-215219494

470 50 300 DE4-BR1-470-050219495

470 140 1000 DE4-BR1-470-140219497

DEX-LM3..., DE4-BU4-1, DE4-BR1

Page 38: Kapitel 15 G Online

Moeller HPL0211-2007/2008

15/38

http://catalog.moeller.net http://catalog.moeller.net

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Technical Data Technical DataFrequency inverters Frequency inverters

DF51-322-025 DF51-322-037 DF51-322-055 DF51-322-075 DF51-322-1K1 DF51-322-1K5 DF51-322-2K2 DF51-320-4K0 DF51-320-5K5 DF51-320-7K5

GeneralHeat dissipation with rated operational current Ie W 19 29 32 41 51 79 107 0 0 0

Dimensions (W x x D) mm 80 x 120 x 105 80 x 120 x 119 80 x 120 x 142 110 x 130 x 127 110 x 130 x 127 110 x 130 x 127 110 x 130 x 127 110 x 130 x 127 180 x 220 x 155 180 x 220 x 155Weight kg 0.8 0.95 0.95 1.4 1.4 1.9 1.9 1.9 5.5 5.7

Power sectionRated operating voltage V AC 230 230 230 230 230 230 230 230 230 230Rated voltage Ue V 1 AC 180…264 V g 0 %

3 AC 180…264 V 0 %1 AC 180…264 V 0 %3 AC 180…264 V 0 %

3 AC 180…264 V 0 %

Supply frequency Hz 50/60 (47…63 0 %) 50/60 (47…63 0 %) 50/60 (47…63 0 %) 50/60 (47…63 0 %) 50/60 (47…63 0 %) 50/60 (47…63 0 %) 50/60 (47…63 0 %) 50/60 (47…63 0 %) 50/60 (47…63 0 %) 50/60 (47…63 0 %)Mains current

= 230 V AC monoph. A 3.1 5.8 6.7 9 11.2 17.5 24 – – –9.3 13 20 30 40260…370 0 % 260…370 0 % 260…370 0 % 260…370 0 % 260…370 0 %

dth modulation (PWM), U/f characteristic control

ted between 2 and 14 kHz3 AC e 3 AC e 3 AC e 3 AC e 3 AC e

oint values, maximum frequency/1000 with analog setpoint valuesum frequency for digital reference values, 0.2 % of maximum frequency for analog reference values

7.1 10 15.9 24 32ry 600 sr higher with torque boost activated

2.9 4.1 6.6 9.9 13.2

1.5 2.2 4 5.5 7.5m

ct, 230 V AC, 0.2 A inductive load, 2.5 A resistive load; or 24 V DC, 0.7 A inductive load, 3 A resistive load

RS485 RS485 RS485 RS485 RS485

+10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA+24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA

line/offline parameterization), parameter protection (programmable)

figurable (input impedance 10 kO, 4 to 20 mA (load impedance 250 O), resolution 10 bit

stor (open-collector, configurable), 1 mA (configurable), resolution 10 bit

4 4 2.5 4 412 12 14 12 12

1.5 1.5 1.5 1.5 1.56 6 6 6 6

1.5 1.5 1.5 1.5 1.56 6 6 6 6

15/39

DF51 DF51

i

i = 230 V AC triph. A 1.8 3.4 3.9 5.2 6.5Alternative DC supply DC V DC 260…370 0 % 260…370 0 % 260…370 0 % 260…370 0 % 260…370 0 %Modulation method sinusoidal pulse-width modulation (PWM), /f characteristic control sinusoidal pulse-wi

Switching frequency 5 kHz, can be selected between 2 and 14 kHz 5 kHz, can be selecOutput voltage V 3 AC e 3 AC e 3 AC e 3 AC e 3 AC e

Output frequency Hz 0 to 50, max. 400 0 to 50, max. 400Frequency resolution kHz 0.1 with digital setpoint values, maximum frequency/1000 with analog setpoint values 0.1 with digital setpFrequency error limit at 20 C 10 K 0.01 % of maximum frequency for digital reference values, 0.2 % of maximum frequency for

analog reference values 0.01 % of maxim

Max. rated operational current e A 1.4 2.6 3 4 5Permissible overcurrent 150 % for 60 s, every 600 s 150 % for 60 s, eveTorque during start From 6 Hz 100 % or higher with torque boost activated From 6 Hz 100 % oApparent power at 240 V kVA 0.5 1 1.2 1.6 2Standard operation at 150 % overload Assigned motor rating (4-pole ASM)

230 V kW 0.25 0.37 0.55 0.75 1.1240 V HP k m o m

Control circuit1 changeover contact, 230 V AC, 0.2 A inductive load, 2.5 A resistive load; or 24 V DC, 0.7 A inductive load, 3 A resistive load

1 changeover conta

Serial interface RS485 RS485 RS485 RS485 RS485Control voltage

Output setpoint voltage V +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mAOutput control voltage V +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA

Parameterization 1 parameter set (online/offline parameterization), parameter protection (programmable) 1 parameter set (on

Inputsdigital (parameters can be defined) 5 +24 V DC, configurable 5 +24 V DC, conAnalog Inputs Amount 2 0 to +10 V DC (input impedance 10 kO, 4 to 20 mA (load impedance 250 O), resolution 10

bit2 x 0 to +10 V DC

OutputsDigital 2 x 24 V DC transistor (open-collector, configurable) 2 x 24 V DC transianalog (parameters can be defined) 1 x 0 to +10 V DC, 1 mA (configurable), resolution 10 bit 1 x 0 to +10 V DC

Terminal capacities

2 1.5 1.5 1.5 2.5 2.5AWG 16 16 16 14 14

Relay connectionmm2 1.5 1.5 1.5 1.5 1.5AWG 6 6 6 6 6

Control circuitmm2 1.5 1.5 1.5 1.5 1.5AWG 6 6 6 6 6

NotesTa is taken to be the temperature inside this enclosure or control panel.

All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, for operation of a four-pole three-phase asynchronous motor.

Page 39: Kapitel 15 G Online

Moeller HPL0211-2007/2008

15/40

Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Technical Data Technical DataFrequency inverters Frequency inverters

DF51-340-037 DF51-340-075 DF51-340-1K5 DF51-340-2K2 DF51-340-3K0 DF51-340-4K0 DF51-340-5K5 DF51-340-7K5

GeneralHeat dissipation with rated operational current Ie

W 32 44 65 92 138 151 219 261

Dimensions (W x H x D) mm 110 x 130 x 141 110 x 130 x 168 110 x 130 x 168 110 x 130 x 168 110 x 130 x 168 110 x 130 x 168 180 x 220 x 167 180 x 220 x 167Weight kg 1.4 1.8 1.9 1.9 1.9 1.9 5.5 5.7

Power sectionRated operating voltage V AC 400 400 400 400 400 400 400 400Rated voltage Ue V 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 %Supply frequency Hz 50/60 (47…63 g 0 %) 50/60 (47…63 g 0 %)Mains current

11 16.5 20480…740 g 0 % 480…740 g 0 % 480…740 g 0 %

th modulation (PWM), U/f characteristic controled between 2 and 14 kHz

3 AC Ue 3 AC Ue 3 AC Ue

oint values/maximum frequency/1000 with analog setpoint valuesm frequency for digital reference values, g 0.2 % of maximum frequency for analog reference values

8.6 13 16ry 600 s 150 % for 60 s, every 600 s 150 % for 60 s, every 600 s 150 % for 60 s, every 600 s

higher with torque boost activated6.6 10.3 12.7

4 5.5 7.55 7 m 10

ct, 230 V AC, 0.2 A inductive load, 2.5 A resistive load; or 24 V DC, 0.7 A inductive load, 3 A resistive load

RS485 RS485 RS485

+10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA+24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA

line/offline parameterization), parameter protection (programmable)

igurable(input impedance 10 kO, 4 to 20 mA (load impedance 250 O), resolution 10 bit

tor (open-collector, configurable) 1 mA (configurable), resolution 10 bit

4 4 412 12 12

1.5 1.5 1.56 6 6

1.5 1.5 1.56 6 6

15/41

DF51 DF51

Ui = 3-phase, 400 V AC I A 2 3.3 5 7 10Alternative DC supply UDC V DC 480…740 g 0 % 480…740 g 0 % 480…740 g 0 % 480…740 g 0 % 480…740 g 0 %

Modulation method sinusoidal pulse-width modulation (PWM), U/f characteristic control sinusoidal pulse-widSwitching frequency 5 kHz, can be selected between 2 and 14 kHz 5 kHz, can be selectOutput voltage V 3 AC Ue 3 AC Ue 3 AC Ue 3 AC Ue 3 AC Ue

Output frequency Hz 0 to 50, max. 400 0 to 50, max. 400Frequency resolution Hz 0.1, with digital setpoint values/maximum frequency/1000 with analog setpoint values 0.1, with digital setpFrequency error limit at 20 C g 10 K g 0.01 % of maximum frequency for digital reference values, g 0.2 % of maximum frequency for analog

reference valuesg 0.01 % of maximu

Max. rated operational current Ie A 1.5 2.5 3.8 5.5 7.8Permissible overcurrent 150 % for 60 s, every

600 s150 % for 60 s, every 600 s

150 % for 60 s, every 600 s

150 % for 60 s, every 600 s

150 % for 60 s, eve

Torque during start From 6 Hz 100 % or higher with torque boost activated From 6 Hz 100 % orApparent power at 460 V kVA 1.1 1.9 2.9 4.2 6.2Resistor R B at 100 % c.d.f.

400 V kW 0.37 0.75 1.5 2.2 3460 V HP m 1 2 3 4

Control circuitRelay 1 changeover contact, 230 V AC, 0.2 A inductive load, 2.5 A resistive load; or 24 V DC, 0.7 A inductive

load, 3 A resistive load1 changeover conta

Serial interface RS485 RS485 RS485 RS485 RS485Control voltage

Output setpoint voltage V +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mAOutput control voltage V +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA

Parameterization 1 parameter set (online/offline parameterization), parameter protection (programmable) 1 parameter set (onInputsdigital (parameters can be defined) 5 x +24 V DC, configurable 5 x +24 V DC, conf

Analog Inputs Amount 2 x 0 to +10 V DC (input impedance 10 kO, 4 to 20 mA (load impedance 250 O), resolution 10 bit 2 x 0 to +10 V DC Outputs

Digital 2 x 24 V DC transistor (open-collector, configurable) 2 x 24 V DC transisanalog (parameters can be defined) 1 x 0 to +10 V DC, 1 mA (configurable), resolution 10 bit 1 x 0 to +10 V DC,

Terminal capacitiesCable lengths

mm2 1.5 1.5 1.5 2.5 2.5AWG 16 16 16 14 14

Relay connectionmm2 1.5 1.5 1.5 1.5 1.5AWG 6 6 6 6 6

Control circuitmm2 1.5 1.5 1.5 1.5 1.5AWG 6 6 6 6 6

Notes If the frequency inverter is to be installed in an enclosure, control panel or similar housing, the ambient temperature Ta is taken to be the temperature inside this enclosure or control panel.All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, for operation of a four-pole three-phase asynchronous motor.

Page 40: Kapitel 15 G Online

15/42Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Technical Data Technical DataVector frequency inverters Vector frequency inverters

DV51-322-025 DV51-322-037 DV51-322-055 DV51-322-075 DV51-322-1K1 DV51-322-1K5 DV51-322-2K2 DV51-320-4K0 DV51-320-5K5 DV51-320-7K5GeneralHeat dissipation with rated operational current Ie W 21 26 29 41 55 90 105 0 0 0

Dimensions (W H D) mm 80 120 103 80 120 117 80 120 117 110 130 139 110 130 139 110 130 166 110 130 166 110 130 166 180 220 155 180 220 155Weight kg 0.7 0.85 0.95 1.3 1.3 1.8 1.8 1.8 5.5 5.7

Rated operating voltage V AC 230 230 230 230 230 230 230 230 230 230Rated voltage e V 1 AC 180…264 V 0 %

3 AC 180…264 V 0 %1 AC 180…264 V 0 %3 AC 180…264 V 0 %

3 AC 180…264 V 0 %

Supply frequency Hz 50/60 (47…63 0 %) 50/60 (47…63 0 %)Mains current

i = 230 V AC monoph. A 3.5 5.8 6.7 9 11.2 17.5 24 – – –10 14 22 30 40260…370 0 % 260…370 0 % 260…370 0 % 260…370 0 % 260…370 0 %

ntrol, pulse width modulation (PWM)ed between 2 and 14 kHz

3 AC e 3 AC e 3 AC e 3 AC e 3 AC e

oint values/maximum frequency/1000 with analog setpoint valuesm frequency for digital reference values, 0.2 % of maximum frequency for analog reference values

8 11 17.5 24 32y 600 sn 200 % with sensorless vector control

3.3 4.5 7.2 9.9 13.3

1.5 2.2 4 5.5 7.52 3 5 7.5 10

380 380 380 380 38070 70 70 70 7040 36 40 36 36

t, 230 V AC, 0.2 A inductive load, 2.5 A resistive load; or 24 V DC, 0.7 A inductive load, 3 A resistive load

RS485 RS485 RS485 RS485 RS485

+10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA+24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA

igurableinput impedance 10 k , 4 to 20 mA (load impedance 250 ), resolution 10 bit

tor (open-collector, configurable)1 mA (configurable), resolution 10 bit

4 4 2.5 4 412 12 14 12 12

1.5 1.5 1.5 1.5 1.56 6 6 6 6

1.5 1.5 1.5 1.5 1.56 6 6 6 6

DV51 DV51

i = 230 V AC triph. A 2 3.4 3.9 5.2 6.5Alternative DC supply DC V DC 260…370 0 % 260…370 0 % 260…370 0 % 260…370 0 % 260…370 0 %Modulation method Sensorless vector control, pulse width modulation (PWM) Sensorless vector coSwitching frequency 5 kHz, can be selected between 2 and 14 kHz 5 kHz, can be selectOutput voltage V 3 AC e 3 AC e 3 AC e 3 AC e 3 AC e

Output frequency Hz 0 to 50, max. 400 0 to 50, max. 400Frequency resolution Hz 0.1, with digital setpoint values/maximum frequency/1000 with analog setpoint values 0.1, with digital setpFrequency error limit at 20 C 10 K 0.01 % of maximum frequency for digital reference values, 0.2 % of maximum frequency for

analog reference values 0.01 % of maximu

Max. rated operational current e A 1.6 2.6 3 4 5Permissible overcurrent 150 % for 60 s, every 600 s 150 % for 60 s, everTorque during start From 1 Hz: more than 200 % with sensorless vector control From 1 Hz: more thaApparent power at 240 V kVA 0.6 1 1.2 1.6 2Standard operation at 150 % overload Assigned motor rating (4-pole ASM)

230 V kW 0.25 0.37 0.55 0.75 1.1240 V HP 1 1

Brake transistorSwitching threshold DC V DC 380 380 380 380 380Lowest impedance B 100 100 100 100 70Duty factor % DF 40 54 36 53 44

Relay 1 changeover contact, 230 V AC, 0.2 A inductive load, 2.5 A resistive load; or 24 V DC, 0.7 A inductive load, 3 A resistive load

1 changeover contac

Serial interface RS485 RS485 RS485 RS485 RS485Control voltage

Output setpoint voltage V +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mAOutput control voltage V +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA

Parameterization 2 2Inputs

digital (parameters can be defined) 6 +24 V DC, configurable 6 +24 V DC, confAnalog Inputs Amount 2 0 to +10 V DC (input impedance 10 k , 4 to 20 mA (load impedance 250 ), resolution 10 bit 2 0 to +10 V DC (

OutputsDigital 2 24 V DC transistor (open-collector, configurable) 2 24 V DC transisanalog (parameters can be defined) 1 0 to +10 V DC, 1 mA (configurable), resolution 10 bit 1 0 to +10 V DC,

Cable lengthsmm2 1.5 1.5 1.5 2.5 2.5AWG 16 16 16 14 14

Relay connectionmm2 1.5 1.5 1.5 1.5 1.5AWG 6 6 6 6 6

Control circuitmm2 1.5 1.5 1.5 1.5 1.5AWG 6 6 6 6 6

If the frequency inverter is to be installed in an enclosure, control panel or similar housing, the ambient temperature a is taken to be the temperature inside this enclosure or control panel.All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, for operation of a four-pole three-phase asynchronous motor.

Page 41: Kapitel 15 G Online

Moeller HPL0211-2007/2008

15/44

Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Technical Data Technical DataVector frequency inverters Vector frequency inverters

DV51-340-037 DV51-340-075 DV51-340-1K5 DV51-340-2K2 DV51-340-3K0 DV51-340-4K0 DV51-340-5K5 DV51-340-7K5

GeneralHeat dissipation with rated operational current Ie

W 26 42 70 95 130 150 219 261

Dimensions (W x H x D) mm 110 x 130 x 139 110 x 130 x 166 110 x 130 x 166 110 x 130 x 166 110 x 130 x 166 110 x 130 x 166 180 x 220 x 155 180 x 220 x 155Weight kg 1.3 1.7 1.8 1.8 1.8 1.8 5.5 5.7

Power sectionRated operating voltage V AC 400 400 400 400 400 400 400 400Rated voltage Ue V 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 %Supply frequency Hz 50/60 (47…63 g 0 %) 50/60 (47…63 g 0 %)Mains current

Ui = 3-phase, 400 V AC I A 2 3.3 5 7 10 11 16.5 20480…740 g 0 % 480…740 g 0 % 480…740 g 0 %

ntrol, pulse width modulation (PWM)d between 2 and 14 kHz

3 AC Ue 3 AC Ue 3 AC Ue

oint values/maximum frequency/1000 with analog setpoint valuesm frequency for digital reference values, g 0.2 % of maximum frequency for analog reference values

8.6 13 16y 600 sn 200 % with sensorless vector control

6.6 10.3 12.2

4 5.5 7.55 7 m 10

760 760 760100 70 70

100 70 7040 36 37

t, 230 V AC, 0.2 A inductive load, 2.5 A resistive load; or 24 V DC, 0.7 A inductive load, 3 A resistive load

RS485 RS485 RS485

+10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA+24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA

igurableinput impedance 10 kO, 4 to 20 mA (load impedance 250 O), resolution 10 bit

tor (open-collector, configurable)1 mA (configurable), resolution 10 bit

4 4 412 12 12

1.5 1.5 1.56 6 6

1.5 1.5 1.56 6 6

15/45

DV51 DV51

Alternative DC supply UDC V DC 480…740 g 0 % 480…740 g 0 % 480…740 g 0 % 480…740 g 0 % 480…740 g 0 %

Modulation method Sensorless vector control, pulse width modulation (PWM) Sensorless vector coSwitching frequency 5 kHz, can be selected between 2 and 14 kHz 5 kHz, can be selecteOutput voltage V 3 AC Ue 3 AC Ue 3 AC Ue 3 AC Ue 3 AC Ue

Output frequency Hz 0 to 50, max. 400 0 to 50, max. 400Frequency resolution Hz 0.1, with digital setpoint values/maximum frequency/1000 with analog setpoint values 0.1, with digital setpFrequency error limit at 20 C g 10 K g 0.01 % of maximum frequency for digital reference values, g 0.2 % of maximum frequency for analog reference

valuesg 0.01 % of maximu

Max. rated operational current Ie A 1.5 2.5 3.8 5.5 7.8Permissible overcurrent 150 % for 60 s, every 600 s 150 % for 60 s, everTorque during start From 1 Hz: more than 200 % with sensorless vector control From 1 Hz: more thaApparent power at 460 V kVA 1.1 1.9 2.9 4.2 6.2Resistor R B at 100 % c.d.f.

400 V kW 0.37 0.75 1.5 2.2 3460 V HP m 1 2 3 4

Brake transistorSwitching threshold UDC V DC 760 760 760 760 760Standard operation at 150 % overload Assigned motor rating (4-pole ASM)

R O 500 300 200 150 100

Lowest impedance RB O 180 180 180 100 100Duty factor % DF 54 53 40 36 40

Control circuitRelay 1 changeover contact, 230 V AC, 0.2 A inductive load, 2.5 A resistive load; or 24 V DC, 0.7 A inductive load, 3 A

resistive load1 changeover contac

Serial interface RS485 RS485 RS485 RS485 RS485Control voltage

Output setpoint voltage V +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mA +10 DC, 10 mAOutput control voltage V +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA +24 DC, 30 mA

Parameterization 2 2Inputsdigital (parameters can be defined) 6 x +24 V DC, configurable 6 x +24 V DC, conf

Analog Inputs Amount 2 x 0 to +10 V DC (input impedance 10 kO, 4 to 20 mA (load impedance 250 O), resolution 10 bit 2 x 0 to +10 V DC (Outputs

Digital 2 x 24 V DC transistor (open-collector, configurable) 2 x 24 V DC transisanalog (parameters can be defined) 1 x 0 to +10 V DC, 1 mA (configurable), resolution 10 bit 1 x 0 to +10 V DC,

Terminal capacitiesCable lengths

mm2 1.5 1.5 1.5 2.5 2.5AWG 16 16 16 14 14

Relay connectionmm2 1.5 1.5 1.5 1.5 1.5AWG 6 6 6 6 6

Control circuitmm2 1.5 1.5 1.5 1.5 1.5AWG 6 6 6 6 6

Notes If the frequency inverter is to be installed in an enclosure, control panel or similar housing, the ambient temperature Ta is taken to be the temperature inside this enclosure or control panel.All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, for operation of a four-pole three-phase asynchronous motor.

Page 42: Kapitel 15 G Online

Moeller HPL0211-2007/2008

15/46

Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Technical Data Technical DataVector frequency inverters Vector frequency inverters

DF6-340-11K DF6-340-15K DF6-340-18K5 DF6-340-22K DF6-340-30K DF6-340-37K

Power lossat 100 % e W 600 800 975 1150 1550 1900at 70 % e W 435 575 698 820 1100 1345

Efficiency % 94.8 94.8 95 95 95 95.1Dimensions (W x H x D) mm 216 x 266 x 190.5 216 x 266 x 190.5 256 x 396 x 210.5 256 x 396 x 210.5 256 x 396 x 210.5 316 x 546 x 215.5Weight kg 5 5 12 12 12 20

Power sectionRated operating voltage V AC 400 400 400 400 400 400Rated voltage e V 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC Supply frequency Hz 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %)Mains current

= 3-phase, 400 V AC A 24 32 41 47 63 77420…760 420…760

ation (PWM), / -predetermined controlted between 0.5 and 12 kHz

3 AC e 3 AC e

0.5 – 50, max. 400 0.5 – 50, max. 400tpoint values/maximum frequency/1000 with analog setpoint valuesximum frequency with digital setpoint values, g0.2 % of the maximum frequency with analog setpoint values

57 70 % for 0.5 s, every 600 sad characteristic (base frequency 30 – 400 Hz)

39.4 48.447.3 58.1

30 3740 50

– –– –– –– –

r, temperature switchntact, 230 V AC/0.2 A inductive load/2.5 A resistive load or 24 V DC/0.7 A inductive load/3 A resistive load,2 x make contacts, 230 V AC/1 A resistive load or 24 V DC/1 A inductive load/5 A resistive load

RS 422, RS 485 RS 422, RS 485

+10 DC, 20 mA +10 DC, 20 mA+24 DC, 100 mA +24 DC, 100 mA

nline/offline parameterization), parameter protection (programmable)

parameterizable, 1 x FWD) (clockwise rotating field)put impedance 10 kO, 4 – 20 mA (load impedance 100 O)

mA 1 x 0/+10 V DC, 2 mA 1 x 0/+10 V DC, 2 mApedance max. 250 O)

mA 0…10 V, max. 1.2 mA 0…10 V, max. 1.2 mA

25 353 1

0.14…1.5 0.14…1.526…16 26…16

0.14…1.5 0.14…1.516… 6 16… 6

15/47

DF6 DF6

i

Alternative DC supply DC V DC 420…760 420…760 420…760 420…760Modulation method Pulse width modulation (PWM), / -predetermined control Pulse width modulSwitching frequency 5 kHz, can be selected between 0.5 and 12 kHz 5 kHz, can be selecOutput voltage V 3 AC e 3 AC e 3 AC e 3 AC e

Output frequency Hz 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400Frequency resolution Hz 0.1, with digital setpoint values/maximum frequency/1000 with analog setpoint values 0.1, with digital seFrequency error limit at 20 C g 10 K g0.01 % of the maximum frequency with digital setpoint values, g0.2 % of the maximum frequency

with analog setpoint valuesg0.01 % of the ma

Max. rated operational current e A 22 29 37 43Permissible overcurrent 120 % for 60 s/150 % for 0.5 s, every 600 s 120 % for 60 s/150Torque during start Quadratic, linear load characteristic (base frequency 30 – 400 Hz) Quadratic, linear loApparent power at 400 V kVA 15.2 20 25.6 29.7Apparent power at 480 V kVA 18.2 24.1 30 35.7Standard operation with 120 % overload. Assigned motor rating (4-pole ASM)

400 V kW 11 15 18.5 22460 V HP 15 20 25 30

Brake transistorSwitching threshold DC V DC 740 740 – –Resistor B at 100 % c.d.f. O 150 150 – –Lowest impedance B O 50 50 – –Max. duty factor (c.d.f.) with lowest impedance B

% DF 10 10 – –

Control circuitThermistor input 1 x PTC thermistor, temperature switch 1 x PTC thermistoRelay 1 x changeover contact, 230 V AC/0.2 A inductive load/2.5 A resistive load or 24 V DC/0.7 A inductive

load/3 A resistive load,2 x make contacts, 230 V AC/1 A inductive load/5 A resistive load or 24 V DC/1 A inductive load/5 A resistive load

1 x changeover coinductive load/5 A

Serial interface RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485Control voltage

Output setpoint voltage V +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mAOutput control voltage V +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA

Parameterization 2 parameter sets (online/offline parameterization), parameter protection (programmable) 2 parameter sets (o

Inputsdigital (parameters can be defined) 6 x +24 V DC (5 x parameterizable, 1 x FWD) (clockwise rotating field) 6 x +24 V DC (5 xanalog, 8 bit resolution Amount 2 x 0/+10 V DC (input impedance 10 kO, 4 – 20 mA (load impedance 100 O) 2 x 0/+10 V DC (in

Outputsanalog (parameters can be defined), 8 bit resolution

1 x 0/+10 V DC, 2 mA 1 x 0/+10 V DC, 2 mA 1 x 0/+10 V DC, 2 mA 1 x 0/+10 V DC, 24 – 20 mA (load impedance max. 250 O) 4 – 20 mA (load im

PWM (parameters can be defined) 0…10 V, max. 1.2 mA 0…10 V, max. 1.2 mA 0…10 V, max. 1.2 mA 0…10 V, max. 1.2

Terminal capacitiesCable lengths

mm2 6 10 16 25AWG 8 6 6 4

Relay connectionmm2 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5AWG 26…16 26…16 26…16 26…16

Control circuitmm2 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5AWG 16… 6 16… 6 16… 6 16… 6

Notes If the frequency inverter is to be installed in a control panel, enclosure or similar installation, the prevalent ambient within these enclosuresor control panels is considered to be the ambient temperature a.All rating data of the power section are based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, with operation of a four pole three-phase asynchronous motor.

Page 43: Kapitel 15 G Online

Moeller HPL0211-2007/2008

15/48

Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Technical Data Technical DataFrequency inverters Frequency inverters

DF6-340-45K DF6-340-55K DF6-340-75K DF6-340-90K DF6-340-110K DF6-340-132K

Power lossat 100 % e W 2300 2800 3800 4800 5500 6650at 70 % e W 1625 1975 2675 3375 3900 4670

Efficiency % 95.1 95.1 95.2 95.2 95.2 95.2Dimensions (W x H x D) mm 396 x 556 x 270.5 396 x 556 x 270.5 396 x 556 x 270.5 396 x 706 x 290.5 396 x 706 x 290.5 486 x 746 x 282Weight kg 30 30 30 60 60 80

Power sectionRated operating voltage V AC 400 400 400 400 400 400Rated voltage e V 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC Supply frequency Hz 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %)

215 253420…760 420…760

ion (PWM), / -predetermined controld between 0.5 and 8 kHz

3 AC e 3 AC e

0.5…50, max. 360 0.5…50, max. 360oint values/maximum frequency/1000 with analog setpoint valuesimum frequency with digital setpoint values, g0.2 % of the maximum frequency with analog setpoint values

195 230 for 0.5 s, every 600 s

d characteristic (base frequency 30 – 400 Hz)135 159162 191

110 132150 175

– –– –– –– –

temperature switchtact, 230 V AC/0.2 A inductive load/2.5 A resistive load or 24 V DC/0.7 A inductive load/3 A resistive load,2 x make contacts, 230 V AC/1 A sistive load or 24 V DC/1 A inductive load/5 A resistive load

RS 422, RS 485 RS 422, RS 485

+10 DC, 20 mA +10 DC, 20 mA+24 DC, 100 mA +24 DC, 100 mA

line/offline parameterization), parameter protection (programmable)

parameterizable, 1 x FWD) (clockwise rotating field)ut impedance 10 kO, 4 – 20 mA (load impedance 100 O)

A 1 x 0/+10 V DC, 2 mA 1 x 0/+10 V DC, 2 mAedance max. 250 O)A 0…10 V, max. 1.2 mA 0…10 V, max. 1.2 mA

2 x 50 2 x 702 x 1/0 2 x 1/0

0.14…1.5 0.14…1.526…16 26…16

0.14…1.5 0.14…1.516… 6 16… 6

15/49

DF6 DF6

Mains current

i = 3-phase, 400 V AC A 94 116 149 176Alternative DC supply DC V DC 420…760 420…760 420…760 420…760Modulation method Pulse width modulation (PWM), / -predetermined control Pulse width modulatSwitching frequency 5 kHz, can be selected between 0.5 and 12 kHz 5 kHz, can be selecteOutput voltage V 3 AC e 3 AC e 3 AC e 3 AC e

Output frequency Hz 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400Frequency resolution Hz 0.1, with digital setpoint values/maximum frequency/1000 with analog setpoint values 0.1, with digital setpFrequency error limit at 20 C g 10 K g0.01 % of the maximum frequency with digital setpoint values, g0.2 % of the maximum frequency

with analog setpoint valuesg0.01 % of the max

Max. rated operational current e A 85 105 135 160Permissible overcurrent 120 % for 60 s/150 % for 0.5 s, every 600 s 120 % for 60 s/150 %Torque during start Quadratic, linear load characteristic (base frequency 30 – 400 Hz) Quadratic, linear loaApparent power at 400 V kVA 58.8 72.7 93.5 111Apparent power at 480 V kVA 70.1 87.1 112 133Standard operation with 120 % overload. Assigned motor rating (4-pole ASM)

400 V kW 45 55 75 90460 V HP 60 75 100 125

Brake transistorSwitching threshold DC V DC – – – –Resistor B at 100 % c.d.f. O – – – –Lowest impedance B O – – – –Max. duty factor (c.d.f.) with lowest impedance B

% DF – – – –

Control circuitThermistor input 1 x PTC thermistor, temperature switch 1 x PTC thermistor, Relay 1 x changeover contact, 230 V AC/0.2 A inductive load/2.5 A resistive load or 24 V DC/0.7 A inductive

load/3 A resistive load,2 x make contacts, 230 V AC/1 A inductive load/5 A resistive load or 24 V DC/1 A inductive load/5 A resistive load

1 x changeover coninductive load/5 A re

Serial interface RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485Control voltage

Output setpoint voltage V +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mAOutput control voltage V +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA

Parameterization 2 parameter sets (online/offline parameterization), parameter protection (programmable) 2 parameter sets (onInputs

digital (parameters can be defined) 6 x +24 V DC (5 x parameterizable, 1 x FWD) (clockwise rotating field) 6 x +24 V DC (5 x analog, 8 bit resolution Amount 2 x 0/+10 V DC (input impedance 10 kO, 4 – 20 mA (load impedance 100 O) 2 x 0/+10 V DC (inp

Outputsanalog (parameters can be defined), 8 bit resolution 1 x 0/+10 V DC, 2 mA 1 x 0/+10 V DC, 2 mA 1 x 0/+10 V DC, 2 mA 1 x 0/+10 V DC, 2 m

4 – 20 mA (load impedance max. 250 O) 4 – 20 mA (load impPWM (parameters can be defined) 0…10 V, max. 1.2 mA 0…10 V, max. 1.2 mA 0…10 V, max. 1.2 mA 0…10 V, max. 1.2 m

Terminal capacitiesCable lengths

mm2 35 50 2 x 35 2 x 35AWG 1 1/0 2 x 1 2 x 1

Relay connectionmm2 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5AWG 26…16 26…16 26…16 26…16

Control circuitmm2 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5AWG 16… 6 16… 6 16… 6 16… 6

Notes If the frequency inverter is to be installed in a control panel, enclosure or similar installation, the prevalent ambient within these enclosuresor control panels is considered to be the ambient temperature a.All rating data of the power section are based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, with operation of a four pole three-phase asynchronous motor.

Page 44: Kapitel 15 G Online

Moeller HPL0211-2007/2008

15/50

Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Technical Data Technical DataVector frequency inverters Vector frequency inverters

DV6-340-075 DV6-340-1K5 DV6-340-2K2 DV6-340-4K0 DV6-340-5K5 DV6-340-7K5 DV6-340-11K DV6-340-15K DV6-340-18K5

Power lossat 100 % e W 88 125 1650 235 325 425 600 800 975at 70 % e W 72.6 102 127 179 242 312 435 575 698

Efficiency % 91.5 92.3 93.2 94 94.4 94.5 94.5 94.6 94.7Dimensions (W x H x D) mm 159 x 260,5 x 152 159 x 260,5 x 152 159 x 260,5 x 152 159 x 260,5 x 152 159 x 260,5 x 152 216 x 266 x 182 216 x 266 x 182 256 x 396 x 210 256 x 396 x 210Weight kg 3.5 3.5 3.5 3.5 3.5 5 5 12 12

Power sectionRated operating voltage V AC 400 400 400 400 400 400 400 400 400Rated voltage e V 342 – 528 V g 0 % 3-

phase AC 342 – 528 V g 0 % 3-phase AC

342 – 528 V g 0 % 3-phase AC

342 – 528 V g 0 % 3-phase AC

342 – 528 V g 0 % 3-phase AC

342 – 528 V g 0 % 3-phase AC

342 – 528 V g 0 % 3-phase AC

342 – 528 V g 0 % 3-phase AC

342 – 528 V g 0 % 3-phase AC

+0 %)

13 18 25 35 42420…760 420…760 420…760 420…760 420…760

trol, pulse width modulation (PWM)

d between 0.5 and 15 kHz3 AC e 3 AC e 3 AC e 3 AC e 3 AC e

0.5…50, max. 400 0.5…50, max. 400 0.5…50, max. 400 0.5…50, max. 400 0.5…50, max. 400oint values/maximum frequency/1000 with analog setpoint values

mum frequency with digital setpoint values, g0.2 % of the maximum frequency with analog setpoint values

12 16 23 32 38 for 0.5 s, every 600 s

sorless vector control mode)8.3 11 15.9 22.1 26.39.9 13.3 19.1 26.6 31.5

5.5 7.5 11 15 18.57.5 10 15 20 25

740 740 740 – –200 150 150 – –70 50 50 – –10 10 10 – –

or (open-collector, configurable)ax. 2 mA), 4…20 mA (max. load impedance 250 O)

.2 mA

15/51

DV6 DV6

Supply frequency Hz 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 Mains current

i = 3-phase, 400 V AC A 2.8 4.2 5.8 9.5Alternative DC supply DC V DC 420…760 420…760 420…760 420…760Modulation method Sensorless vector control, pulse width modulation (PWM) Sensorless vector con

Switching frequency 5 kHz, can be selected between 0.5 and 15 kHz 5 kHz, can be selecteOutput voltage V 3 AC e 3 AC e 3 AC e 3 AC e

Output frequency Hz 0.5…50, max. 400 0.5…50, max. 400 0.5…50, max. 400 0.5…50, max. 400Frequency resolution Hz 0.1, with digital setpoint values/maximum frequency/1000 with analog setpoint

values0.1, with digital setp

Frequency error limit at 20 C g 10 K g0.01 % of the maximum frequency with digital setpoint values, g0.2 % of the maximum frequency with analog setpoint values

g0.01 % of the maxi

Max. rated operational current e A 2.5 3.8 5.3 8.6Permissible overcurrent 150 % for 60 s/200 % for 0.5 s, every 600 s 150 % for 60 s/200 %Torque during start 200 % at 0.5 Hz (sensorless vector control mode) 200 % at 0.5 Hz (senApparent power at 400 V kVA 1.7 2.6 3.6 5.9Apparent power at 480 V kVA 2 3.1 4.4 7.1Standard operation with 150 % overload. Assigned motor rating (4-pole ASM)

400 V kW 0.75 1.5 2.2 4460 V HP 1 2 3 5

Brake transistorSwitching threshold DC V DC 740 740 740 740Resistor B at 100 % c.d.f. O 300 300 300 200Lowest impedance B O 100 100 100 70Max. duty factor (c.d.f.) with lowest impedance B

% DF 10 10 10 10

OutputsDigital 5 x 24 V DC transistor (open-collector, configurable) 5 x 24 V DC transistanalog (parameters can be defined), 8 bit resolution

3 x 0…+10 V DC (max. 2 mA), 4…20 mA (max. load impedance 250 O) 3 x 0…+10 V DC (m

PWM (parameters can be defined) 1 x 0…10 V, max. 1.2 mA 1 x 0…10 V, max. 1

Notes If the frequency inverter is to be installed in a control panel, enclosure or similar installation, the prevalent ambient within these enclosuresor control panels is considered to be the ambient temperature a. All rating data of the power section are based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, with operation of a four pole three-phase asynchronous motor.

Page 45: Kapitel 15 G Online

Moeller HPL0211-2007/2008

15/52

Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Technical Data Technical DataVector frequency inverters Vector frequency inverters

DV6-340-075 DV6-340-1K5 DV6-340-2K2 DV6-340-4K0 DV6-340-5K5 DV6-340-7K5 DV6-340-11K DV6-340-15K DV6-340-18K5

Control circuitRelay 1 x changeover contact, 230 V AC/0.2 A inductive load/2.5 A resistive load or 24

V DC/0.7 A inductive load/3 A resistive load1 x changeover contact, 230 V AC/0.2 A inductive load/2.5 A resistive load or 24 V DC/0.7 A inductive load/3 A resistive load

Serial interface RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485Control voltage

Output setpoint voltage V +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mAOutput control voltage V +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA

Parameterization 3 parameter sets (online/offline parameterization), parameter protection (programmable)

3 parameter sets (online/offline parameterization), parameter protection (programmable)

Inputstemperature switch impedance 4.7 kO) impedance 4.7 kO)10 V DC (input impedance 10 kO), 4…20 mA (load impedance 100 O)

or (open-collector, configurable)ax. 2 mA), 4…20 mA (max. load impedance 250 O)

.2 mA

2.5 4 6 10 1612 10 8 6 6

0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.526…16 26…16 26…16 26…16 26…16

0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.526…16 26…16 26…16 26…16 26…16

15/53

DV6 DV6

Thermistor input 1 x PTC thermistor, temperature switch 1 x PTC thermistor, Clockwise rotating field enable (FWD) 1 x +24 V DC (input impedance 4.7 kO) 1 x +24 V DC (inputdigital (parameters can be defined) 8 x +24 V DC (input impedance 4.7 kO) 8 x +24 V DC (inputanalog, 12 bit resolution Amount 3 x 0 – +10 V DC, g10 V DC (input impedance 10 kO), 4…20 mA (load

impedance 100 O)3 x 0 – +10 V DC, g

OutputsDigital 5 x 24 V DC transistor (open-collector, configurable) 5 x 24 V DC transistanalog (parameters can be defined), 8 bit resolution

3 x 0…+10 V DC (max. 2 mA), 4…20 mA (max. load impedance 250 O) 3 x 0…+10 V DC (m

PWM (parameters can be defined) 1 x 0…10 V, max. 1.2 mA 1 x 0…10 V, max. 1

Terminal capacitiesCable lengths

mm2 1.5 2.5 2.5 2.5AWG 20 18 16 14

Relay connectionmm2 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5AWG 26…16 26…16 26…16 26…16

Control circuitmm2 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5AWG 26…16 26…16 26…16 26…16

Notes 1) If the frequency inverter is to be installed in a control panel, enclosure or similar installation, the prevalent ambient within these enclosuresor control panels is considered to be the ambient temperature a. All rating data of the power section are based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, with operation of a four pole three-phase asynchronous motor.

Page 46: Kapitel 15 G Online

Moeller HPL0211-2007/2008

15/54

Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Technical Data Technical DataVector frequency inverters Vector frequency inverters

DV6-340-22K DV6-340-30K DV6-340-37K DV6-340-45K DV6-340-55K DV6-340-75K DV6-340-90K DV6-340-110K DV6-340-132K

Power lossat 100 % e W 1150 1550 1900 2300 2800 3750 4500 5500 6500at 70 % e W 820 1100 1345 1625 1975 2600 3100 3800 4500

Efficiency % 94.8 94.8 94.9 94.9 94.9 95 95 95 95.1Dimensions (W x H x D) mm 256 x 396 x 210 310 x 540 x 202,2 390 x 550 x 255,2 390 x 550 x 255,2 390 x 550 x 255,2 390 x 700 x 275,2 390 x 700 x 275,2 480 x 740 x 293,2 480 x 740 x 293,2Weight kg 12 20 30 30 30 60 60 80 80Power sectionRated operating voltage V AC 400 400 400 400 400 400 400 400 400Rated voltage e V 342 – 528 V g 0 % 3-phase AC 342 – 528 V g 0 % 3-phase AC

+0 %)

121 164 194 239 286420…760 420…760 420…760 420…760 420…760

ntrol, pulse width modulation (PWM)

d between 0.5 and 15 kHz3 AC e 3 AC e 3 AC e 3 AC e 3 AC e

0.5…50, max. 400 0.5…50, max. 400 0.5…50, max. 400 0.5…50, max. 400 0.5…50, max. 400oint values/maximum frequency/1000 with analog setpoint values

imum frequency with digital setpoint values, g0.2 % of the maximum frequency with analog setpoint values

110 149 176 217 260 for 0.5 s, every 600 s

sorless vector control mode)76.2 103.2 121.9 150.3 180.191.4 123.8 146.3 180.4 216.1

55 75 90 110 13275 100 125 150 175

tact, 230 V AC/0.2 A inductive load/2.5 A resistive load or 24 V DC/0.7 A inductive load/3 A resistive load

RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485

+10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA+24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA

line/offline parameterization), parameter protection (programmable)

temperature switcht impedance 4.7 kO)t impedance 4.7 kO)10 V DC (input impedance 10 kO), 4…20 mA (load impedance 100 O)

tor (open-collector, configurable)ax. 2 mA), 4…20 mA (max. load impedance 250 O)

1.2 mA

2 x 35 2 x 35 2 x 50 2 x 70 2 x 701/0 2 x 1 2 x 1 2 x 1/0 2 x 2/0

0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.526…16 26…16 26…16 26…16 26…16

0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.526…16 26…16 26…16 26…16 26…16

15/55

DV6 DV6

Supply frequency Hz 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63Mains current

i = 3-phase, 400 V AC A 53 63 83 99Alternative DC supply DC V DC 420…760 420…760 420…760 420…760Modulation method Sensorless vector control, pulse width modulation (PWM) Sensorless vector co

Switching frequency 5 kHz, can be selected between 0.5 and 15 kHz 5 kHz, can be selecteOutput voltage V 3 AC e 3 AC e 3 AC e 3 AC e

Output frequency Hz 0.5…50, max. 400 0.5…50, max. 400 0.5…50, max. 400 0.5…50, max. 400Frequency resolution Hz 0.1, with digital setpoint values/maximum frequency/1000 with analog setpoint

values0.1, with digital setp

Frequency error limit at 20 C g 10 K g0.01 % of the maximum frequency with digital setpoint values, g0.2 % of the maximum frequency with analog setpoint values

g0.01 % of the max

Max. rated operational current e A 48 58 75 90Permissible overcurrent 150 % for 60 s/200 % for 0.5 s, every 600 s 150 % for 60 s/200 %Torque during start 200 % at 0.5 Hz (sensorless vector control mode) 200 % at 0.5 Hz (senApparent power at 400 V kVA 33.2 40.1 51.9 62.3Apparent power at 480 V kVA 39.9 48.2 62.3 74.8Standard operation with 150 % overload. Assigned motor rating (4-pole ASM)

400 V kW 22 30 37 45460 V HP 30 40 50 60

Control circuitRelay 1 x changeover contact, 230 V AC/0.2 A inductive load/2.5 A resistive load or 24

V DC/0.7 A inductive load/3 A resistive load1 x changeover con

Serial interface RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485Control voltage

Output setpoint voltage V +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mAOutput control voltage V +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA

Parameterization 3 parameter sets (online/offline parameterization), parameter protection (programmable)

3 parameter sets (on

InputsThermistor input 1 x PTC thermistor, temperature switch 1 x PTC thermistor,Clockwise rotating field enable (FWD) 1 x +24 V DC (input impedance 4.7 kO) 1 x +24 V DC (inpudigital (parameters can be defined) 8 x +24 V DC (input impedance 4.7 kO) 8 x +24 V DC (inpuanalog, 12 bit resolution Amount 3 x 0 – +10 V DC, g10 V DC (input impedance 10 kO), 4…20 mA (load

impedance 100 O)3 x 0 – +10 V DC, g

OutputsDigital 5 x 24 V DC transistor (open-collector, configurable) 5 x 24 V DC transisanalog (parameters can be defined), 8 bit resolution 3 x 0…+10 V DC (max. 2 mA), 4…20 mA (max. load impedance 250 O) 3 x 0…+10 V DC (mPWM (parameters can be defined) 1 x 0…10 V, max. 1.2 mA 1 x 0…10 V, max.

Terminal capacitiesCable lengths

mm2 16 25 35 35AWG 4 3 1 1

Relay connectionmm2 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5AWG 26…16 26…16 26…16 26…16

Control circuitmm2 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5AWG 26…16 26…16 26…16 26…16

Notes 1) If the frequency inverter is to be installed in a control panel, enclosure or similar installation, the prevalent ambient within these enclosuresor control panels is considered to be the ambient temperature a. All rating data of the power section are based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 °C, with operation of a four pole three-phase asynchronous motor.

Page 47: Kapitel 15 G Online

Moeller HPL0211-2007/2008

15/56

Moeller HPL0211-2007/2008http://catalog.moeller.net http://catalog.moeller.net

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Technical Data Technical DataRadio interference suppression filters Radio interference suppression filter

DE6-LZ3-013-V4 DE6-LZ3-032-V4 DE6-LZ3-064-V4 DE6-LZ3-080-V4 DE6-LZ3-115-V4 DE6-LZ3-125-V4 DE6-LZ3-150-V4 DE6-LZ3-220-V4 DE6-LZ3-260-V4

GeneralStandards EN 50178, IEC 61800-3, EN 61800-3 incl. A11 EN 50178, IEC 61800-3, EN 61800-3 incl. A11Environmental conditions

Operating temperature °C –25…+85 –25…+85 –25…+85 –25…+85 –25…+85 –25…+85 –25…+85 – –25…+85Altitude m 0…1000 a.s.l., derating above 1000: e…2 %/1000 m 0…1000 a.s.l., derating above 1000: e…2 %/1000 mMounting position As required, vertically suspended preferred As required, vertically suspended preferredFree surrounding areas In connection area (cable, terminals): 100 mm In connection area (cable, terminals): 100 mmHumidity class C C C C C C C C CClimatic class (IEC) – – – – – –

70 x 440 x 110 70 x 440 x 110 130 x 525 x 94 130 x 525 x 94 142 x 620 x 1166.4 6.7 8.8 9.3 13.7

2064 2064 2064 2064 20642064 2064 2064 2064 2064

30 30 30 30 30750 750 380 380 600

400 400 400 400 4000 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 %+0 %)

– – – – –115 125 150 220 260

s 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes

38 45 40 60 50

50 50 95 95 9550 50 95 95 953 x 35 3 x 35 3 x 50 3 x 70 3 x 95

M10 M10 M10 M10 M12

15/57

DE6-LZ3... DE6-LZ3...

Protection type IP20 (terminal) IP20 (terminal)Dimensions (W x H x D) mm 143 x 255 x 29 203 x 260 x 43 244 x 390 x 45 60 x 400 x 87Weight kg 1.4 2.5 4.5 4.3

Electrical dataTest voltage in V DC, 2 s

Phase/neutral pole V 2064 2064 2064 2064Phase/PE V 2064 2064 2064 2064

Leakage currentMax. leakage current in operation mA 30 30 30 30Max. leakage current PE and 2 external conductors disconnected

mA 180 280 550 690

Rated operating voltage V AC 400 400 400 400Rated voltage e V 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g Supply frequency Hz 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 Rated operational current

i = 1-phase, 230 V AC A – – – –

i = 3-phase, 400 V AC A 13 32 64 80Permissible overcurrent 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minute

Heat dissipation with rated operational current e W 12 14 36 32

Terminal capacitiesSolid mm2 4 10 25 35flexible mm2 4 6 16 25Cables to frequency inverter mm2 3 x 2.5 3 x 6 3 x 16 3 x 16

AWGPE stud M5 M5 M8 M8

Notes 1) All rating data is based on an ambient temperature of +40°C.

00

0.2

0.4

0.6

0.8

1.0

1.2

20 40 60 80 100

IBIN

i[°C]

Page 48: Kapitel 15 G Online

15/58Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

Technical DataRadio interference suppression filter

DE51-LZ1-007-V2

DE51-LZ1-012-V2

DE51-LZ1-024-V2

DE51-LZ3-007-V4

DE51-LZ3-011-V4

DE51-LZ3-020-V4

GeneralStandards EN 50178, IEC 61800-3, EN 61800-3 incl. A11Environmental conditions

Operating temperature °C –25…+100Altitude m 0…1000 a.s.l., derating above 1000: Ie…2 %/1000 mMounting position As required, vertically suspended preferredFree surrounding areas In connection area (cable, terminals): 80 mmHumidity class CClimatic class (IEC) 25/085/21

Protection type IP 20 (terminals)Dimensions (W x H x D) mm 80 x 170 x 27 110 x 180 x 35 110 x 180 x 35 110 x 285 x 40Weight kg 0.45 0.5 0.67 0.7 0.75 1.2

Electrical dataTest voltage in V DC, 2 s

Phase/neutral pole V 1100 1100 1100 2100 2100 2100Phase/PE V 2550 2550 2550 2650 2650 2650

Leakage currentMax. leakage current in operation mA < 6 < 6 < 6 < 11 < 35 < 46Max. leakage current when PE disconnected

mA < 25 < 26 < 24 < 4 < 5 < 5.5

Max. leakage current when PE and N disconnected

mA < 47 < 51 < 48 – – –

Max. leakage current PE and 2 external conductors disconnected

mA – – – < 156 < 198 < 210

Rated operating voltage V AC 230 230 230 400 400 400Rated voltage Ue V 1 AC 250 V 3 AC 480 VSupply frequency Hz 50/60 (47…63 g 0 %)Rated operational current

Ui = 1-phase, 230 V AC I A 7 12 24 – – –Ui = 3-phase, 400 V AC I A – – – 7 11 20

Permissible overcurrent 150 % for 60 s, every 30 minutesHeat dissipation with rated operational current Ie

W 5 7 12 4 7 12

Terminal capacitiesSolid mm2 0.2…4flexible mm2 0.2…4Cables to frequency inverter mm2 2 x 1.5, 180 mm 2 x 2.5, 250 mm

AWG 18 16 12 18 16 12PE stud M5 x 15

Notes All rating data is based on an ambient temperature of +40°C.

00

0.2

0.4

0.6

0.8

1.0

1.2

20 40 60 80 100

IBIN

i[°C]

DE51-LZ...

Page 49: Kapitel 15 G Online

15/59

http://catalog.moeller.net Moeller HPL0211-2007/2008

Technical DataMains chokes, motor chokes

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Mains chokes DEX-LN1-… Mains choke DEX-LN3-… Motor chokes DEX-LM3-…

General

Standards IEC/EN 61558-2-20-2000, VDE 0570 Part 2-20/04-2001, UL, CSAOperating temperature °C –25…+40, up to 70 with current reduction (see notes)Storage temperature °C –25…+85 –25…+85 –25…+85Shock resistance 11 ms2/15 g, 3 impacts 11 ms2/15 g, 3 impacts 11 ms2/15 g, 3 impactsVibration resistance g 1 (at 0…150 Hz) 1 (at 0…150 Hz) 1 (at 0…150 Hz)Vibration 0.35 mm at 10…55 Hz 0.35 mm at 10…55 Hz 0.35 mm at 10…55 HzPollution degree 1 (VDE 0160) 1 (VDE 0160) 1 (VDE 0160)Altitude m 0 to 1000 above sea level, up to 5000 with current derating (see notes)Mounting position Standing vertically, suspended horizontallyFree surrounding areas < 50 < 50 < 50Degree of protection (terminals) IP20 IP20 up to 40 A

IP 00 from 50 AIP20 up to 50 AIP20 from 63 A

Rated duty factor % DF 100 100 100

Overload cycle 1.5 x Ie for 60 s every 600 s 1.5 x Ie for 60 s every 600 s 1.5 x Ie for 60 s every 600 s (< 24 A)1.2 x Ie for 60 s every 600 s (> 24 A)

Weight kg 0.7 1.5 1.5

Electrical dataRated voltage Ue V AC 230 400 400

Max. supply voltage UL V AC 260 g 0 % 550 g 0 % 750 g 0 %

Operating frequency Hz 50/60 50/60 0…200Insulation class B B B (100 A) F (150 A)

Electrical connectionTerminations K K (40 A) K (50 A)Connection lugs – K (50 A) K (63 A)PE stud K K K

Notes 1) The following applies for the installation altitude: Derating with respect to the rated current Ie:

0.50 2000 4000

0.6

0.7

0.8

0.9

1.0

1000 3000 5000

I

Ie

h [m]

DEX-LN, DEX-LM3

Page 50: Kapitel 15 G Online

15/60Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

Technical DataLine reactors, motor reactors

Part no. Inductance Rated current Heat dissipation

Voltage drop Connection

Terminal/connection lug Hole Tightening torque

L Ie PVCU uk

mH A W % mm² AWG mm NmSingle-phase mains chokes, rated voltage 1 AC 230 V, 50 HzDEX-LN1-006 5.05 5.8 9 4 4 20 – 10 – 0.8DEX-LN1-009 3.41 8.6 11 4 4 20 – 10 – 0.8DEX-LN1-013 2.25 13 12 4 4 20 – 10 – 0.8DEX-LN1-018 1.63 18 17 4 4 20 – 10 – 0.8DEX-LN1-024 1.22 24 20 4 4 20 – 10 – 0.8Three-phase mains chokes, rated voltage 3 AC 400 V, 50 HzDEX-LN3-004 7.51 3.9 17 4 4 20 – 10 – 0.8DEX-LN3-006 4.9 6 19 4 4 20 – 10 – 0.8DEX-LN3-010 2.94 10 33 4 4 20 – 10 – 0.8DEX-LN3-016 1.84 16 44 4 4 20 – 10 – 0.8DEX-LN3-025 1.18 25 57 4 4 20 – 10 – 0.8DEX-LN3-040 0.64 40 59 2.5 10 20 – 6 – 1.5DEX-LN3-050 0.37 50 58 2.5 Cu 15 x 2 7 3DEX-LN3-060 0.31 60 60 2.5 Cu 15 x 2 7 3DEX-LN3-080 0.23 80 86 2.5 Cu 20 x 3 9 6DEX-LN3-100 0.186 100 101 2.5 Cu 20 x 3 9 6DEX-LN3-120 0.15 120 100 2.5 Cu 25 x 5 11 10DEX-LN3-160 0.11 160 140 2.5 Cu 25 x 5 11 10DEX-LN3-200 0.09 200 154 2.5 Cu 25 x 5 11 10DEX-LN3-250 0.07 250 155 2.5 Cu 40 x 5 14 15.5DEX-LN3-300 0.06 300 169 2.5 Cu 40 x 5 14 15.5

Part no. Inductance Rated current Heat dissipation (clock frequency) Connection

Terminal/connection lug Hole Tightening torque

L Ie PVCU(3 kHz)

PVCU(5 kHz)

PVCU(12 kHz)

mH A W W W mm² AWG mm NmThree-phase motor chokes, rated voltage 3 AC 400 V, max. 200 HzDEX-LM3-005 2 5 12 14 24 4 20 – 10 – 0.8DEX-LM3-008 4.1 8 32 46 54 4 20 – 10 – 0.8DEX-LM3-011 3 11 45 66 71 4 20 – 10 – 0.8DEX-LM3-016 1.5 16 50 75 78 4 20 – 10 – 0.8DEX-LM3-035 1 35 75 114 116 4 20 – 10 – 0.8DEX-LM3-050 0.6 50 110 157 168 10 20 – 6 – 1.5DEX-LM3-063 0.5 63 130 190 193 Cu 15 x 2 7 3DEX-LM3-080 0.5 80 132 206 206 Cu 20 x 3 9 6DEX-LM3-100 0.45 100 177 279 294 Cu 20 x 3 9 6DEX-LM3-150 0.35 150 293 418 424 Cu 25 x 5 11 10DEX-LM3-180 0.3 180 418 298 439 Cu 25 x 5 11 10DEX-LM3-220 0.2 220 344 512 517 Cu 40 x 5 14 15.5DEX-LM3-260 0.15 260 358 526 520 Cu 40 x 5 14 15.5

DEX-LN, DEX-LM3

Page 51: Kapitel 15 G Online

15/61

http://catalog.moeller.net Moeller HPL0211-2007/2008

DimensionsFrequency inverters

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Frequency invertersDF51-322-025…DF322-055DV51-322-025…DV322-055

DF51-322-075…DF51-320-4K0DV51-322-075…DV51-320-4K0DF51-340-037…DF51-340-4K0DV51-340-037…DV51-340-4K0

DF51-320-5K5…DF51-320-7K5DV51-320-5K5…DV51-320-7K5DF51-340-5K5…DF51-340-7K5DV51-340-5K5…DV51-340-7K5

a DF51 only

b1 bb2a1

a

o

b1 bb2a1

a

o

b1 bb2a1

a

oC

a

Part no. a a1 b b1 b2 c O Weightmm mm mm mm mm mm mm kg

DF51-322-025 80 67 120 110 10 105 5 0.8DF51-322-037 80 67 120 110 10 119 5 0.95DF51-322-055 80 67 120 110 10 142 5 0.95DF51-322-075 110 98 130 118 10 141 5 1.4DF51-322-1K1 110 98 130 118 10 141 5 1.4DF51-322-1K5 110 98 130 118 10 168 5 1.9DF51-322-2K2 110 98 130 118 10 168 5 1.9DF51-320-4K0 110 98 130 118 10 168 5 1.9DF51-320-5K5 180 164 220 205 – 167 6 5.5DF51-320-7K5 180 164 220 205 – 167 6 5.7DF51-340-037 110 98 130 118 10 141 5 1.4DF51-340-075 110 98 130 118 10 168 5 1.8DF51-340-1K5 110 98 130 118 10 168 5 1.9DF51-340-2K2 110 98 130 118 10 168 5 1.9DF51-340-3K0 110 98 130 118 10 168 5 1.9DF51-340-4K0 110 98 130 118 10 168 5 1.9DF51-340-5K5 180 164 220 205 – 167 6 5.5DF51-340-7K5 180 164 220 205 – 167 6 5.7

DV51-322-025 80 67 120 110 10 103 5 0.7DV51-322-037 80 67 120 110 10 117 5 0.85DV51-322-055 80 67 120 110 10 117 5 0.95DV51-322-075 110 98 130 118 10 139 5 1.3DV51-322-1K1 110 98 130 118 10 139 5 1.3DV51-322-1K5 110 98 130 118 10 166 5 1.8DV51-322-2K2 110 98 130 118 10 166 5 1.8DV51-320-4K0 110 98 130 118 10 166 5 1.8DV51-320-5K5 180 164 220 205 – 155 6 5.5DV51-320-7K5 180 164 220 205 – 155 6 5.7DV51-340-037 110 98 130 118 10 139 5 1.3DV51-340-075 110 98 130 118 10 166 5 1.7DV51-340-1K5 110 98 130 118 10 166 5 1.8DV51-340-2K2 110 98 130 118 10 166 5 1.8DV51-340-3K0 110 98 130 118 10 166 5 1.8DV51-340-4K0 110 98 130 118 10 166 5 1.8DV51-340-5K5 180 164 220 205 – 155 6 5.5DV51-340-7K5 180 164 220 205 – 155 6 5.7

DF51, DV51

Page 52: Kapitel 15 G Online

15/62Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

DimensionsFrequency inverters, Accessories

Frequency invertersDF6 DV6

Braking unitDE4-BU4-1

a1

d

b1 b

a

c

Part no. a a1 b b1 c dmm mm mm mm mm mm

DF6-340-11K 216 189 266 246 190.5 7DF6-340-15K 216 189 266 246 190.5 7DF6-340-18K5 256 229 396 376 210.5 7DF6-340-22K 256 229 396 376 210.5 7DF6-340-30K 256 229 396 376 210.5 7DF6-340-37K 316 265 546 510 215.5 10DF6-340-45K 396 300 556 520 270.5 10DF6-340-55K 396 300 556 520 270.5 10DF6-340-75K 396 300 556 520 270.5 10DF6-340-90K 396 300 706 670 290.5 12DF6-340-110K 396 300 706 670 290.5 12DF6-340-132K 486 380 746 730 282 12

Part no. a a1 b b1 c dmm mm mm mm mm mm

DV6-340-075 159 130 260.5 241 152 6DV6-340-1K5 159 130 260.5 241 152 6DV6-340-2K2 159 130 260.5 241 152 6DV6-340-4K0 159 130 260.5 241 152 6DV6-340-5K5 159 130 260.5 241 152 6DV6-340-7K5 216 189 266 246 190.5 7DV6-340-11K 216 189 266 246 190.5 7DV6-340-15K 256 229 396 376 210.5 7DV6-340-18K5 256 229 396 376 210.5 7DV6-340-22K 256 229 396 376 210.5 7DV6-340-30K 310 265 540 510 202 10DV6-340-37K 390 300 550 520 255.5 10DV6-340-45K 390 300 550 520 255.5 10DV6-340-55K 390 300 550 520 255.5 10DV6-340-75K 390 300 700 670 275.5 12DV6-340-90K 390 300 700 670 275.5 12DV6-340-110K 480 380 740 710 293.2 12DV6-340-132K 480 380 740 710 293.2 12

186

52

6.5

26

350

365

384

o

o

Part no. ø Weightkg

DE4-BU4-1 M6 1.2

Braking resistorsDE4-BR1-…

c

a1

a

b1

b

b1

a1

d

Part no. a a1 b b1 c d Weightmm mm mm mm mm mm kg

DE4-BR1-470-050 205 185 70 50 95 6x15 0.4DE4-BR1-200-100 265 245 70 50 95 6x15 1.2DE4-BR1-470-140 305 285 70 50 95 6x15 0.5DE4-BR1-240-285 405 385 70 50 95 6x15 2.8DE4-BR1-082-245 405 385 70 50 95 6x15 1.7DE4-BR1-100-200 405 385 70 50 95 6x15 1.7DE4-BR1-370-215 405 385 70 50 95 6x15 1.7

D1Z-145308 T 180R 405 385 95 70 120 6x15 3D1Z-165408 T 82R 505 485 95 70 120 6x15 3.5D1Z-185408 T 68R 505 485 120 95 140 6x15 5D1Z-185608 T 47R 705 685 120 95 140 6x15 6D1Z-265608 T 33R 705 685 180 155 120 6x15 9

DF6-..., DV6-..., DE4-...

Page 53: Kapitel 15 G Online

15/63

http://catalog.moeller.net Moeller HPL0211-2007/2008

DimensionsAccessories

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

KeypadsDEX-KEY-6 DEX-KEY-10

DEX-KEY-61

Mounting frameDEX-MNT-K6

Interface moduleDE51-NET-CAN DE51-NET-DP

Hz

A

RUN

POWER

ALARM

PRG

PRG ENTER

54.8

69.5

59

I O

10 12

13 8

5

3

6.5

26.5

80

o 4

210

3 123

q 18

10

Hz

A

RUN

POWER

ALARM

PRG

PRG ENTER

54.8

69.5

59I O

50 5

7

2

3 9

12

o 4.2

94.4

74 63.4

66.5

83.4

22.5

34

120

82

129

120

82

125

22.5

34

Mounting framesDEX-MNT-NET DEV51-MNT-K60

121

85

142

23

118

78

22

18

DEX-..., DE51-...

Page 54: Kapitel 15 G Online

15/64Fr

eque

ncy

inve

rter

sVe

ctor

freq

uenc

y in

vert

ers

Moeller HPL0211-2007/2008 http://catalog.moeller.net

DimensionsRadio interference suppression filter

Radio interference suppression filterDE51-LZ3-...-V4 DE51-LZ1-...-V2

DE6-LZ3-...-V4

a1

d1

b2

b1

a

b

b3

l

c

c1

c2

d

d

b2

b

c

c1

c2

a1

M5 x 15

PE

a

d1

d

d

b3

b1

l

Part no. a a1 b b1 b2 b3 c c1 c2 d d1 l

mm mm mm mm mm mm mm mm mm mm mm kg mmDE51-LZ1-007-V2 80 67 170 160 110 120 27 20 13.5 5 2x6 0.45 160DE51-LZ1-012-V2 110 98 180 170 118 130 35 28 17.5 5 4x6 0.5 180DE51-LZ1-024-V2 110 98 180 170 118 130 35 28 17.5 5 4x6 0.67 180DE51-LZ3-007-V4 110 98 180 170 118 130 35 28 17.5 5 4x6 0.7 180DE51-LZ3-011-V4 110 98 180 170 118 130 35 28 17.5 5 4x6 0.75 180DE51-LZ3-020-V4 180 164 285 269 205 220 40 31 20 6.3 4x6.5 1.2 250

c a1

d

b1 b

a

PE

b1 b

c a1

PE

a

d

Part no. a a1 b b1 c d PE Weightmm mm mm mm mm mm kg

DE6-LZ3-013-V4 143 130 255 241 29 4x6 M5x19 1.4DE6-LZ3-032-V4 203 189 260 246 246 4x7 M5x19 2.5DE6-LZ3-064-V4 244 229 390 376 45 4x7 M8x24 4.5

Part no. a a1 b b1 c d PE Weightmm mm mm mm mm mm kg

DE6-LZ3-080-V4 60 40 400 380 87 4x8.5 M8x24 4.3DE6-LZ3-115-V4 70 50 440 420 110 4x8.5 M10x34 6.4DE6-LZ3-125-V4 70 50 440 420 110 4x8.5 M10x34 6.7DE6-LZ3-150-V4 130 105 525 505 94 4x9 M10x34 8.8DE6-LZ3-220-V4 130 105 525 505 94 4x9 M10x34 9.3DE6-LZ3-220-V4 142 120 620 600 116 4x9 M12x48 13.7

DE51-..., DE6-...

Page 55: Kapitel 15 G Online

15/65

http://catalog.moeller.net Moeller HPL0211-2007/2008

DimensionsMains choke, motor chokes

Freq

uenc

y in

vert

ers

Vect

or fr

eque

ncy

inve

rter

s

Line reactorsDEX-LN1-…

Line chokes/motor chokesDEX-LN3-…

Line chokes/motor chokesDEX-LN3-…

A) Tolerance dependant upon air-gapThe position of connection lugs U2-V2-W2 depends on the coil material and can deviate from the position illustrated here.

c ±

5

b ± 5

b2

b1� d

a

a1

PE

1 2

c1 ±

5

Part no. a a1 b b1 b2 c c1 d Weightmm mm mm mm mm mm mm mm kg

DEX-LN1-006 66 50 71 44 55 80 61 4.5x8 0.7DEX-LN1-009 66 50 71 44 55 80 61 4.5x8 0.7DEX-LN1-013 84 64 67 47 60 90 75 4.8x8 1.5DEX-LN1-018 84 64 90 70 83 90 75 4.8x8 1.5DEX-LN1-024 84 64 67 47 60 90 75 4.8x8 2

a1

a

b1

b ± 5

b2

c ±

5

� d

PE

W1W2V1 V2U1 U2

c1 ±

5

Part no. a a1 b b1 b2 c c1 d Weightmm mm mm mm mm mm mm mm kg

DEX-LN3-004 115 100 66 50 66 118 84 5x10 1.5DEX-LN3-006 115 100 66 50 66 118 84 5x10 1.5DEX-LN3-010 140 125 61 50 61 138 105 5x10 2.2DEX-LN3-016 140 125 71 50 71 138 105 5x10 2.9DEX-LN3-025 195 175 104 50 76.5 175 134 8x13 4.8DEX-LN3-040 195 175 104 50 76.5 188 134 8x13 4.8

DEX-LM3-005 115 100 66 50 66 118 84 5x10 1.5DEX-LM3-008 195 175 104 50 76.5 175 134 8x13 4.8DEX-LM3-011 195 175 104 50 76.5 175 134 8x13 4.8DEX-LM3-016 195 175 104 50 76.5 175 134 8x13 4.8DEX-LM3-035 220 200 132 75 101.5 195 160 8x13 7.3DEX-LM3-050 270 250 106 75 96 228 198 8x13 12.3

� d b1a1

a b2

b ± 10

c ±

5

PEPE Part no. a a1 b b1 b2 c1) d Weightmm mm mm mm mm mm mm kg

G5DEX-LN3-050 195 175 105 75 91.5 132 8x13 5.9DEX-LN3-060 195 175 105 75 91.5 132 8x13 5.9DEX-LN3-080 220 200 110 50 81.5 160 8x13 7.3DEX-LN3-100 220 200 130 75 101.5 160 8x13 10.2DEX-LN3-120 220 200 130 75 101.5 160 8x13 10.2DEX-LN3-160 270 250 125 75 96 200 8x13 12.3DEX-LN3-200 270 250 155 100 120 202 8x13 14.9DEX-LN3-250 270 250 155 100 125 210 10x18 20.6DEX-LN3-300 270 250 155 100 125 210 10x18 20.6

G10DEX-LM3-063 270 250 155 100 120 202 8x13 14.9DEX-LM3-080 270 250 155 100 125 210 10x18 20.6

G30DEX-LM3-100 384 350 215 100 130 258 12x20 31DEX-LM3-150 384 350 260 150 180 258 12x20 45DEX-LM3-180 384 350 260 150 180 258 12x20 45DEX-LM3-220 384 350 260 150 180 258 12x20 45DEX-LM3-260 384 350 260 150 180 258 12x20 45

DEX-LN...