Upload
ngokhanh
View
222
Download
1
Embed Size (px)
Citation preview
DAFTAR PUSTAKA
1. www.kapanlagi.com/h/0000182852.html
2. http://eprints.ums.ac.id/579/1/1._subroto.pdf
3. Lea, F.M., The Chemistry of Cement and Concrete, Edward Arnold Publishers,
1956
4. www.fhwa.dot.gov
5. Martirena, J.F., et.al, Use of Wastes of the Sugar Industry as Pozzolana in Lime-
Pozzolana Binders: Study of the Reaction, Cement and Concrete Research, Vol.28,
No.11, 1998
6. Sugiri, Saptahari. 1997. Diktat Kuliah Teknologi Beton. Lembaga Penelitian Insitut
Teknologi Bandung.
7. Imran, Iswandi., Diktat Kuliah Pengenalan Rekayasa dan Bahan Konstruksi Sipil.
Penerbit ITB.
8. ASTM C-150. Standard Specification for Portland Cement. Annual Book of ASTM
Standards.
9. ASTM C-125. Standard Terminology Relating to Concrete and Concrete
Aggregates. Annual Book of ASTM Standards.
10. ASTM C-618. Standard Specification for Coal Fly Ash and Raw or Calcined
Natural Pozzolan for Use as a Mineral Admixture in Concrete. Annual Book of
ASTM Standards.
11. Frias, Moises, et.al, Characterisation of sugar cane straw waste as pozzolanic
material for construction: Calcining temperature and kinetic parameters, 2006
12. Sukma, Nurhadi. 2006. Analisa Awal Pemanfaatan Bottom Ash Sebagai Pengganti
Sebagian Semen dalam Campuran Beton. Teknik Material ITB.
13. Elvery, R. H., Concrete Practice, Vol.II , C.R. Books Ltd, 1963
14. matse1.mse.uiuc.edu
15. http://www4.eas.asu.edu/cement/Blended_cements/blended_cements_1998_a.htm
16. http://ciks.cbt.nist.gov/menu0001.html
17. http://www.tomralstonconcrete.com
18. www.whd.co.uk/Concrete/concretebysem.html
xi
19. http://www.oak-creek.netASGNT-2-15-04.ppt
20. http://www.cement.org/basics/concretebasics_lessonfive.asp
21. http://www.chem-is-try.org/?sect=fokus&ext=15
22. www2.dpi.qld.gov.au/sugar/12087.html
23. http://www.vitrominerals.com/general-pozzolan-technical-information.pdf
24. http://www.personal.leeds.ac.uk/~cen6ddm/CEDC_PJW/PJW1.pdf
xii
LAMPIRAN
xiii
Perhitungan Mix Design Beton
(ACI 211.4R-93)
Penetapan Variabel Perencanaan
1. Kategori Jenis Struktur : Kolom
2. Kuat Tekan Rencana : 35 MPa
3. Slump : 75 – 100 mm
4. Ukuran Maksimum Agregat : 12.5 mm
Data
Absorbsi
(%)
Kadar Air
(%)
Berat Jenis Berat Isi
(kg/m3)
Modulus
Kehalusan
Agregat
Halus
5.04
3.09
2.62 (SSD)
1580.39
2.58
Agregat
Kasar
5.85
3.22
2.48 (SSD)
1419.03
-
Semen
3.15
A. Estimasi Kebutuhan Air Pencampuran
Perkiraan kebutuhan air pencampuran diperoleh dari tabel 1 seperti yang tertera di
bawah ini :
xiv
Tabel 1. Kebutuhan air pencampuran dan udara untuk berbagai nilai slump dan ukuran
maksimum agregat.
NON-AIR-ENTRAINED CONCRETE Approximate mixing water (kg/m3) for indicated nominal maximum sizes of
aggregate
Slump (mm) 9.5 mm 12.5 mm 19 mm 25 mm 37.5
mm 50 mm 75 mm 150 mm
25 to 50 207 199 190 179 166 154 130 113 75 to 100 228 216 205 193 181 169 145 124 150 to 175 243 228 216 202 190 178 160 -
Approximate amount of entrapped air in non-air-entrained concrete (%)
Slump (mm) 9.5 mm 12.5 mm 19 mm 25 mm 37.5
mm 50 mm 75 mm 150 mm
All 3.0 2.5 2.0 1.5 1.0 0.5 0.3 0.2
Dari tabel diatas diperoleh data :
Berat air = 216 kg/m3
Udara terperangkap = 2.5 %
Volume udara terperangkap = 0.025
sehingga dapat kita dapat menghitung besarnya volume air yaitu :
Volume air = 216/1000 = 0.216
B. Perhitungan Rencana Kuat Tekan Beton Rata – Rata
ƒm = ƒc’ + 1.64 Sd Sd = 2
= 35 + 1.64 x 2
= 35 + 3.28
= 38.28 MPa
Keterangan :
ƒm = nilai kuat tekan beton rata – rata
ƒc’ = nilai kuat tekan karakteristik ( yang disyaratkan )
Sd = standar deviasi ( lih. tabel standar deviasi )
xv
C. Pemilihan w/c ratio
Rasio air semen diperoleh melalui tabel di bawah ini :
Tabel 2. Hubungan rasio air semen dan kuat tekan beton pada beton tanpa penambahan
udara (* Nilai nilai selain yang ada pada tabel dapat diperoleh melalui interpolasi ).
Kuat Tekan Beton Umur 28 hari (MPa) * Rasio Air Semen
(dalam perbandingan berat)
40 0.42
35 0.47
30 0.54
25 0.61
20 0.69
15 0.79
Melalui Interpolasi diperoleh w/c = 0.45
D. Perhitungan kandungan semen
Dari data w/c ratio kita dapat menghitung :
Kandungan Semen = 216 / 0.45 = 480 kg/m3
Volume Semen = 480 / 3150 = 0.15
E. Estimasi Agregat Kasar
Berdasarkan Tabel 3 dan data ukuran maximum agregat kasar = 12.5 mm dan
modulus kehalusan agregat halus = 2.6 kita dapat memperoleh data volume agregat kasar
per satuan volume beton sebesar 0.57
xvi
Tabel 3. Volume agregat kasar persatuan volume beton untuk beton dengan slump 75 –
100 mm.
Volume of oven-dry-rodded coarse aggregate per unit volume of concrete for different fineness moduli of fine aggregate
Nominal maximum size of aggregate
(mm)
2.40 2.60 2.80 3.00
9.5 0.50 0.48 0.46 0.44 12.5 0.59 0.57 0.55 0.53 19 0.66 0.64 0.62 0.60 25 0.71 0.69 0.67 0.65
37.5 0.75 0.73 0.71 0.69 50 0.78 0.76 0.74 0.72 75 0.82 0.80 0.78 0.76 150 0.87 0.85 0.83 0.81
Berdasarkan tabel 4 serta data slump dan ukuran maksimum agregat kasar diperoleh nilai
faktor koreksi sebesar 1.00
Tabel 4. Faktor koreksi tabel 3 untuk berbagai nilai slump
Faktor koreksi untuk berbagai ukuran maksimum agregat Slump
( mm ) 10 mm 12.5 mm 20 mm 25 mm 40 mm
25 – 50 1.08 1.06 1.04 1.06 1.09
75 – 100 1.00 1.00 1.00 1.00 1.00
150 – 175 0.97 0.98 1.00 1.00 1.00
Dari data – data diatas, dapat dihitung :
Berat agregat kasar per m3 beton = 0.57 x berat volum agregat kasar x faktor koreksi
= 0.57 x 1419.03 x 1.00
= 808.85 kg/m3
Volume agregat kasar = 808.85 kg/m3 : b.j Agregat kasar
= 808.85 : 2480
= 0.33
xvii
F. Estimasi Agregat Halus
Dengan menggunakan metode volume absolute kita dapat menghitung kandungan
agregat halus sebagai berikut :
VA.H = 1 – [ Va + Vu + Vs + VA.K ]
= 1 – [ 0.216 + 0.025 + 0.15 + 0.33 ]
= 1 – [ 0.72 ]
= 0.28
Berat agr. halus per satuan vol beton = 0.28 x berat volum agr. kasar x faktor koreksi
= 0.28 x 1580.39 x 1.00
= 442.51 kg/m3
Berdasarkan perhitungan – perhitungan di atas, dapat dituliskan
Kondisi sebelum dikoreksi :
Semen = 480 kg/m3
Agr.kasar = 808.85 kg/m3
Agr.halus = 442.51 kg/m3
Air = 216 kg/m3
Total = 1947.36 kg/m3
G. Koreksi Kandungan Air
Koreksi penambahan air pada agregat :
Agr. Halus = ( kadar air – absorpsi ) % x berat A.H
= ( 3.09 – 5.04 ) % x 442.51 kg/m3
= - 8.63 kg/m3
Agr. Kasar = ( kadar air – absorpsi ) % x berat A.K
= ( 3.22 – 5.85 ) % x 808.85 kg/m3
= - 21.27 kg/m3
xviii
Kondisi setelah dikoreksi
Semen = 480 kg/m3
Agr.kasar = ( 808.85 – 21.27 ) = 787.58 kg/m3
Agr.halus = ( 442.5 – 8.63 ) = 433.88 kg/m3
Air = ( 216 + 21.27 + 8.63 ) = 245.9 kg/m3
Total = 1947.36 kg/m3
Ukuran Spesimen ( silinder )
φ = 5.7 cm
t = 11.4 cm
r = 2.85 cm
Luas Alas = π r2
= π ( 2.85 cm )2
= 25.52 cm2
Volume = Luas Alas x t
= 25.52 cm2 x 11.4 cm2
= 290.9 cm3
= 0.0002909 m3
Komposisi tiap spesimen
Semen = 480 kg/m3 x 0.0002909 m3 = 0.1396 kg ≈ 140 gr
Agregat Halus = 433.88 kg/m3 x 0.0002909 m3 = 0.1262 kg ≈ 126 gr
Agregat Kasar = 787.58 kg/m3 x 0.0002909 m3 = 0.2291 kg ≈ 230 gr
Air = 245.9 kg/m3 x 0.0002909 m3 = 0.0715 kg ≈ 72 gr
Agr. Kasar
( gr )
Agr. Halus
( gr )
Air
( gr )
Semen
( gr )
Abu Ampas Tebu
( gr )
B1 230 126 72 140 0
B2 230 126 72 133 7
B3 230 126 72 126 14
B4 230 126 72 119 21
xix
Keterangan :
B1 = Beton tanpa penambahan Abu Ampas Tebu
B2 = Beton dengan penambahan 5 % Abu Ampas Tebu
B3 = Beton dengan penambahan 10 % Abu Ampas Tebu
B4 = Beton dengan penambahan 15 % Abu Ampas Tebu
xx
Hasil X-Ray Diffraction 1. X-Ray Diffraction gabungan ( B1 dan B4 )
pa
an
aan
c
a
p
c an
q
p c
pa
an
a an
c
pc a
an p cp
I
2 theta
p - portlanditea - albitec - calcium silicate hydrateq - quartzan - anorthite
2. X-Ray Diffraction B1 (Beton Normal)
B1-1 44-1481 Portlandite
xxi
B1-1 03-0594 Calcium Silicate Hydrate
B1-1 01-0739 Albite
B1-1 02-0523 Anorthite
xxii
3. X-Ray Diffraction B4 (Beton dengan substitusi 15% semen dengan abu ampas
tebu )
B4-3 44-1481 Portlandite
B4-3 03-0594 Calcium Silicate Hydrate
xxiii
B4-3 76-0898 Albite
B4-3 02-0523 Anorthite
B4-3 83-0541 Quartz
xxiv