K2Storage

Cabling Guide

071-8713-01April 2010

Page 2: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Affiliate with the N.V. KEMA in The Netherlands

CERTIFICATECertificate Number: 510040.001 The Quality System of: Thomson Inc, and its wor dwide Grass Valley division affiliates DBA GRASS VALLEY

Headquarters 400 Providence Mine Rd Nevada City, CA 95959 United States

15655 SW Greystone Ct. Beaverton, OR 97006 United States

10 Presidential Way Suite 300 Woburn, MA 01801 United States

Kapittelweg 10 4827 HG Breda The Nederlands

7140 Baymeadows Way Ste 101 Jacksonville, FL 32256 United States

2300 So. Decker Lake Blvd. Salt Lake City, UT 84119 United States

Rue du Clos Courtel CS 31719 35517 Cesson-Sevigné Cedex France

1 rue de l’Hautil Z.I. des Boutries BP 150 78702 Conflans-Sainte Honorine Cedex France

Technopole Brest-Iroise Site de la Pointe du Diable CS 73808 29238 Brest Cedex 3 France

40 Rue de Bray 2 Rue des Landelles 35510 Cesson Sevigné France

Spinnereistrasse 5 CH-5300 Turgi Switzerland

Brunnenweg 9 D-64331 Weiterstadt Germany

Carl-Benz-Strasse 6-8 67105 Schifferstadt Germany

Including its implementation, meets the requirements of the standard:

ISO 9001:2008 Scope:The design, manufacture and support of video and audio hardware and software products and related systems.

This Certificate is valid until: June 14, 2012 This Certificate is valid as of: June 14, 2009 Certified for the first time: June 14, 2000

H. Pierre Sallé President KEMA-Registered Quality

The method of operation for quality certification is defined in the KEMA General Terms And Conditions For Quality And Environmental Management Systems Certifications. Integral publication of this certificate is allowed.

KEMA-Registered Quality, Inc.4377 County Line Road Chalfont, PA 18914 Ph: (215)997-4519 Fax: (215)997-3809 CRT 001 073004

Accredited By:ANAB

Page 3: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2StorageSAN and Direct-Connect

Cabling Guide

071-8713-01April 2010

Page 4: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

4 K2 Storage Cabling Guide 01 April 2010

Copyright Copyright © Grass Valley, Inc. All rights reserved. Printed in the United States of America.Portions of software © 2000 – 2010, Microsoft Corporation. All rights reserved. This documentmay not be copied in whole or in part, or otherwise reproduced except as specifically permittedunder U.S. copyright law, without the prior written consent of Grass Valley, Inc., P.O. Box59900, Nevada City, California 95959-7900. This product may be covered by one or more U.S.and foreign patents.

Disclaimer Product options and specifications subject to change without notice. The information in thismanual is furnished for informational use only, is subject to change without notice, and shouldnot be construed as a commitment by Grass Valley, Inc. Grass Valley, Inc. assumes noresponsibility or liability for any errors or inaccuracies that may appear in this publication.

U.S. Government Restricted Rights Legend

Use, duplication, or disclosure by the United States Government is subject to restrictions as setforth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clauseat DFARS 252.277-7013 or in subparagraph c(1) and (2) of the Commercial ComputerSoftware Restricted Rights clause at FAR 52.227-19, as applicable. Manufacturer is GrassValley, Inc., P.O. Box 59900, Nevada City, California 95959-7900 U.S.A.

Trademarks and Logos

Grass Valley, K2, Aurora, Summit, Dyno, Solo, Infinity, Turbo, Profile, Profile XP, NetCentral,NewsBrowse, NewsEdit, NewsQ, NewsShare, NewsQ Pro, and Media Manager are eitherregistered trademarks or trademarks of Grass Valley, Inc. in the United States and/or othercountries. Grass Valley, Inc. products are covered by U.S. and foreign patents, issued andpending. Additional information regarding Grass Valley, Inc. trademarks and other proprietaryrights may be found at www.grassvalley.com. Other trademarks and logos used in thisdocument are either registered trademarks or trademarks of the manufacturers or vendors ofthe associated products, such as Microsoft® Windows® operating system, Windows Media®player, Internet Explorer® internet browser, and SQL Server™. QuickTime and the QuickTimelogo are trademarks or registered trademarks of Apple Computer, Inc., used under licensetherefrom.

Revision Status

Rev Date Description

03 September 2009

Initial release of the K2 Storage Cabling Guide - 071-8713-00

01 April 2010 Correct NH Server GigE cabling - 071-8713-01

Page 5: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Contents

Chapter 1 Start with the K2 storage system diagramAbout custom K2 SANs........................................................................................... 7Level 2 Basic K2 SAN ............................................................................................. 8Level 2 Redundant K2 SAN .................................................................................... 9Level 3 Basic K2 SAN ............................................................................................. 10Level 3 Redundant K2 SAN .................................................................................... 11Level 10 Basic K2 SAN ........................................................................................... 12Level 10 Redundant K2 SAN .................................................................................. 13Level 20 Basic K2 SAN ........................................................................................... 14Level 20 Redundant K2 SAN .................................................................................. 15Level 30 Basic K2 SAN ........................................................................................... 16Level 30 Redundant K2 SAN .................................................................................. 17Level 35 Basic K2 SAN ........................................................................................... 18Level 35 Redundant K2 SAN .................................................................................. 19Nearline 10 Basic K2 SAN ...................................................................................... 20Nearline 10 Redundant K2 SAN.............................................................................. 21K2 client with direct-connect storage....................................................................... 22

Chapter 2 Cable K2 devicesCable K2 client ........................................................................................................ 24

K2 Media Client for basic K2 SAN...................................................................... 24K2 Media Client for redundant K2 SAN .............................................................. 25K2 Summit Production Client for basic K2 SAN ................................................. 25K2 Summit Production Client for redundant K2 SAN ......................................... 26K2 Media Client with direct-connect storage ...................................................... 26K2 Summit Production Client with direct-connect storage.................................. 27

Cable Gigabit Ethernet switch ................................................................................. 283400cl HP GigE switch for basic K2 SAN........................................................... 283400cl HP GigE switch for redundant K2 SAN................................................... 2929xx HP GigE switch for basic K2 SAN.............................................................. 2929xx HP GigE switch for redundant K2 SAN...................................................... 3029xx HP GigE switch for basic nearline K2 SAN................................................ 3029xx HP GigE switch for redundant nearline K2 SAN ........................................ 31

Cable K2 Media Server ........................................................................................... 32Dell 2850 for basic K2 SAN ................................................................................ 33Dell 2850 for redundant K2 SAN ........................................................................ 33Dell 1950 GS for Level 10 basic K2 SAN ........................................................... 34Dell 1950 GS for Level 10 redundant K2 SAN ................................................... 34Dell 1950 GS for Level 20 basic K2 SAN ........................................................... 35Dell 1950 GS for Level 20 redundant K2 SAN ................................................... 35Dell 1950 GS for Level 35 basic K2 SAN ........................................................... 36Dell 1950 GS for Level 35 redundant K2 SAN ................................................... 37Dell 2950 for basic K2 SAN ................................................................................ 38Dell 2950 for redundant K2 SAN ........................................................................ 38Dell 2950 for Level 3 basic K2 SAN ................................................................... 39Dell 2950 for Level 3 redundant K2 SAN............................................................ 40Dell 2950 LS for basic K2 SAN........................................................................... 41Dell 2950 LS for redundant K2 SAN................................................................... 41Dell R610 GS for Level 10 basic K2 SAN........................................................... 42Dell R610 GS for Level 10 redundant K2 SAN................................................... 42Dell R610 GS for Level 20 basic K2 SAN........................................................... 42Dell R610 GS for Level 20 redundant K2 SAN................................................... 43Dell R610 GS for Level 35 basic K2 SAN........................................................... 43Dell R610 GS for Level 35 redundant K2 SAN................................................... 44Dell R710 LS for basic K2 SAN .......................................................................... 44

01 April 2010 K2 Storage Cabling Guide 5

Page 6: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

6

Contents

Dell R710 LS for redundant K2 SAN .................................................................. 45Cable NH1 K2 Media Server ................................................................................... 46

Dell 1950 NH1 for online K2 SAN ...................................................................... 46Dell 1950 NH1 for basic nearline K2 SAN.......................................................... 46Dell 1950 NH1 for redundant nearline K2 SAN .................................................. 47Dell R610 NH1 for online K2 SAN...................................................................... 47Dell R610 NH1 for basic nearline K2 SAN ......................................................... 47Dell R610 NH1 for redundant nearline K2 SAN ................................................. 48

Cable NH1-10GE K2 Media Server ........................................................................ 49Dell 1950 NH1-10GE for online K2 SAN ............................................................ 49Dell 1950 NH1-10GE for basic nearline K2 SAN ............................................... 49Dell 1950 NH1-10GE for redundant nearline K2 SAN........................................ 50Dell R610 NH1-10GE for online K2 SAN ........................................................... 50Dell R610 NH1-10GE for basic nearline K2 SAN............................................... 50Dell R610 NH1-10GE for redundant nearline K2 SAN ....................................... 51

Cable K2 RAID........................................................................................................ 52K2 RAID for Level 2 basic K2 SAN .................................................................... 53K2 RAID for Level 2 redundant K2 SAN............................................................. 54K2 RAID for basic K2 SAN ................................................................................. 55K2 RAID for redundant K2 SAN ......................................................................... 56K2 RAID for Level 10 basic K2 SAN .................................................................. 57K2 RAID for Level 10 redundant K2 SAN........................................................... 58K2 RAID for Level 20 basic K2 SAN .................................................................. 59K2 RAID for Level 20 redundant K2 SAN........................................................... 60K2 RAID for Level 30 basic K2 SAN .................................................................. 61K2 RAID for Level 30 redundant K2 SAN........................................................... 62K2 RAID for Level 35 basic K2 SAN .................................................................. 63K2 RAID for Level 35 redundant K2 SAN........................................................... 64K2 RAID for Nearline 10 basic K2 SAN.............................................................. 65K2 RAID for Nearline 10 redundant K2 SAN...................................................... 66K2 RAID for K2 client direct-connect storage..................................................... 67

Chapter 3 For more informationK2 Release Notes ................................................................................................... 69K2 Documentation CD ............................................................................................ 69On-line Help Systems ............................................................................................. 70NetCentral documentation ...................................................................................... 70Grass Valley Web Site ............................................................................................ 70Using the Dell Server documentation...................................................................... 70Grass Valley Product Support................................................................................. 71

Web Technical Support ...................................................................................... 71Telephone Support ............................................................................................. 72Waste Electrical and Electronic Equipment Directive......................................... 73

K2 Storage Cabling Guide 01 April 2010

Page 7: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Chapter 1

Start with the K2 storage system dia-gram

To follow cabling instructions for your K2™ Storage Area Network (SAN) or direct-connect storage K2 client, start with the system cabling diagram for your K2 system. Then follow the references below the system diagram to locate cabling instructions for the individual devices of your K2 system.

Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information on K2 SAN levels and devices. Refer to the K2 System Guide for more information on direct-connect K2 client storage.

• “Level 2 Basic K2 SAN” on page 8

• “Level 2 Redundant K2 SAN” on page 9

• “Level 3 Basic K2 SAN” on page 10

• “Level 3 Redundant K2 SAN” on page 11

• “Level 10 Basic K2 SAN” on page 12

• “Level 10 Redundant K2 SAN” on page 13

• “Level 20 Basic K2 SAN” on page 14

• “Level 20 Redundant K2 SAN” on page 15

• “Level 30 Basic K2 SAN” on page 16

• “Level 30 Redundant K2 SAN” on page 17

• “Level 35 Basic K2 SAN” on page 18

• “Level 35 Redundant K2 SAN” on page 19

• “Nearline 10 Basic K2 SAN” on page 20

• “Nearline 10 Redundant K2 SAN” on page 21

About custom K2 SANsCustom systems are those that do not fit one of the pre-defined Level 2, 3, 10, 20, 30, 35, or nearline configurations. For example, a K2 SAN with Fibre Channel attached K2 clients is considered a custom system. Custom systems that are an extension of Level 2 or 3 are considered to be Level 4 systems. Custom systems that are an extension of Level 10, 20, or 30 are considered to be Level 40 systems. Only qualified Grass Valley personnel should attempt to design, install, and configure custom systems.

This document and the other documents in the K2 documentation set are intended for customers with one of the pre-defined SAN levels. While much of the information also applies to custom systems, consult your Grass Valley representative before using procedures on a custom system.

01 April 2010 K2 Storage Cabling Guide 7

Page 8: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

8

Chapter 1 Start with the K2 storage system diagram

Level 2 Basic K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for basic K2 SAN” on page 24

Gigabit Ethernet Switch HP 3400cl series “3400cl HP GigE switch for basic K2 SAN” on page 28

HP 2900 series “29xx HP GigE switch for basic K2 SAN” on page 29

K2 Media Server Dell 2850 “Dell 2850 for basic K2 SAN” on page 33

Dell 2950 “Dell 2950 for basic K2 SAN” on page 38

K2 RAID Level 2 K2 RAID “K2 RAID for Level 2 basic K2 SAN” on page 53

K2 Media Clients

Gigabit Ethernet Switch

FT

P

Control

Media

Control

Media

Control

Media

Control

Control

Media

Media

Control point PC

! ! !

L2 RAID PrimaryChassis

L2 RAID Expansion Chassis (optional)

K2 Media Server

Fibre Channelconnection

POWER SERVICEK2 RAID STORAGE !

POWER SERVICEK2 RAID STORAGE !

Control

FTP/streaming

K2 Storage Cabling Guide 01 April 2010

Page 9: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Level 2 Redundant K2 SAN

Level 2 Redundant K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for redundant K2 SAN” on page 25

Gigabit Ethernet Switch HP 3400cl series “3400cl HP GigE switch for redundant K2 SAN” on page 29

HP 2900 series “29xx HP GigE switch for redundant K2 SAN” on page 30

K2 Media Server Dell 2850 “Dell 2850 for redundant K2 SAN” on page 33

Dell 2950 “Dell 2950 for redundant K2 SAN” on page 38

K2 RAID Level 2 K2 RAID “K2 RAID for Level 2 redundant K2 SAN” on page 54

L2R RAID PrimaryChassis

L2R RAID Expansion Chassis (optional)

K2 MediaServers

A B

A B

K2 Media Clients

Gigabit Ethernetswitches

Fibre Channelconnections

Co

ntro

l B

Me

dia

B

Co

ntro

l A

Me

dia

A

Co

ntro

l A

Me

dia

A

Co

ntro

l B

Me

dia

B

Co

ntro

lF

TP

Me

dia

Me

dia

Co

ntro

lM

ed

iaM

ed

iaF

TP

Control point PC

POWER SERVICEK2 RAID STORAGE !

POWER SERVICEK2 RAID STORAGE !

! ! !

ControlISLs

Co

ntro

l

FTP/streaming

Co

ntro

l B

Me

dia

B

Co

ntro

l A

Media A

01 April 2010 K2 Storage Cabling Guide 9

Page 10: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

10

Chapter 1 Start with the K2 storage system diagram

Level 3 Basic K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for basic K2 SAN” on page 24

Gigabit Ethernet Switch HP 3400cl series “3400cl HP GigE switch for basic K2 SAN” on page 28

HP 2900 series “29xx HP GigE switch for basic K2 SAN” on page 29

K2 Media Server Dell 2850 “Dell 2850 for basic K2 SAN” on page 33

Dell 2950 “Dell 2950 for Level 3 basic K2 SAN” on page 39

K2 RAID Level 3 K2 RAID “K2 RAID for basic K2 SAN” on page 55

K2 Media Clients

Gigabit Ethernet Switch

FT

P

Control

Media

Control

Media

Control

Media

Control

Control

Media

Control

Media

Media

Media

Control point PC

! ! !

L3 RAID PrimaryChassis

L3 RAID Expansion Chassis (optional)

K2 MediaServers

1 2Fibre Channelconnections

POWER SERVICEK2 RAID STORAGE !

POWER SERVICEK2 RAID STORAGE !

POWER SERVICEK2 RAID STORAGE !

POWER SERVICEK2 RAID STORAGE !

Control

FTP/streaming

K2 Storage Cabling Guide 01 April 2010

Page 11: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Level 3 Redundant K2 SAN

Level 3 Redundant K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for redundant K2 SAN” on page 25

Gigabit Ethernet Switch HP 3400cl series “3400cl HP GigE switch for redundant K2 SAN” on page 29

HP 2900 series “29xx HP GigE switch for redundant K2 SAN” on page 30

K2 Media Server Dell 2850 “Dell 2850 for redundant K2 SAN” on page 33

Dell 2950 “Dell 2950 for Level 3 redundant K2 SAN” on page 40

K2 RAID Level 3 K2 RAID “K2 RAID for redundant K2 SAN” on page 56

L3R RAID PrimaryChassis

L3R RAID Expansion Chassis (optional)

K2 MediaServers1A

A B

2A 1B 2B

K2 Media Clients

Gigabit EthernetSwitches

Fibre Channelconnections

Co

ntro

l B

Me

dia

B

Co

ntro

l A

Me

dia

A

Co

ntro

l A

Me

dia

A

Co

ntro

l B

Me

dia

B

Co

ntro

lF

TP

Me

dia

Me

dia

Co

ntro

lM

ed

iaM

ed

ia

Co

ntro

lF

TP

Me

dia

Media

Co

ntro

lM

ed

iaM

ed

ia

Control point PC

POWER SERVICEK2 RAID STORAGE !

POWER SERVICEK2 RAID STORAGE !

POWER SERVICEK2 RAID STORAGE !

POWER SERVICEK2 RAID STORAGE !

! ! !

ControlISLs

Co

ntro

l

Co

ntro

l

FTP/streaming

Co

ntro

l B

Me

dia

B

Co

ntro

l A

Media A

01 April 2010 K2 Storage Cabling Guide 11

Page 12: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

12

Chapter 1 Start with the K2 storage system diagram

Level 10 Basic K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for basic K2 SAN” on page 24

K2 Summit Production Client

“K2 Summit Production Client for basic K2 SAN” on page 25

Gigabit Ethernet Switch HP 2900 series “29xx HP GigE switch for basic K2 SAN” on page 29

K2 Media Server Dell 1950 “Dell 1950 GS for Level 10 basic K2 SAN” on page 34

Dell R610 “Dell R610 GS for Level 10 basic K2 SAN” on page 42

K2 RAID Level 10 K2 RAID “K2 RAID for Level 10 basic K2 SAN” on page 57

RAID PrimaryChassis

RAID Expansion Chassis (optional)

K2 MediaServer

K2 clients

Gigabit Ethernet Switch

Control

Media

Control

Media

Co

ntro

l

FT

P

Me

dia

Control point PC

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 MEDIA SERVER

Control

Co

ntro

l

FTP/streaming

Control

Media

FibreChannel

K2 Storage Cabling Guide 01 April 2010

Page 13: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Level 10 Redundant K2 SAN

Level 10 Redundant K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for redundant K2 SAN” on page 25

K2 Summit Production Client

“K2 Summit Production Client for redundant K2 SAN” on page 26

Gigabit Ethernet Switch HP 2900 series “29xx HP GigE switch for redundant K2 SAN” on page 30

K2 Media Server Dell 1950 “Dell 1950 GS for Level 10 redundant K2 SAN” on page 34

Dell R610 “Dell R610 GS for Level 10 redundant K2 SAN” on page 42

K2 RAID Level 10 K2 RAID “K2 RAID for Level 10 redundant K2 SAN” on page 58

RAID PrimaryChassis

RAID Expansion Chassis (optional)

K2 MediaServers

A B

BA

Gigabit EthernetSwitches

Co

ntro

l B

Me

dia

B

Co

ntro

l A

Me

dia

A

Co

ntro

l A

Me

dia

A

Co

ntro

l B

Me

dia

B

Co

ntro

l

FT

P

Me

dia

Co

ntro

lF

TP

Media

Control point PC

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

K2 clients

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 MEDIA SERVER K2 MEDIA SERVER

ControlISLs

Co

ntro

l

Co

ntro

l

FTP/streaming

Co

ntro

l B

Me

dia

B

Co

ntro

l A

Media A

FibreChannel

FibreChannel

01 April 2010 K2 Storage Cabling Guide 13

Page 14: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

14

Chapter 1 Start with the K2 storage system diagram

Level 20 Basic K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

Multiple NH servers must be of the same type, either all NH1-10GE or all NH1.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for basic K2 SAN” on page 24

K2 Summit Production Client

“K2 Summit Production Client for basic K2 SAN” on page 25

Gigabit Ethernet Switch HP 2900 series “29xx HP GigE switch for basic K2 SAN” on page 29

K2 Media Server Dell 1950 “Dell 1950 GS for Level 20 basic K2 SAN” on page 35

Dell R610 “Dell R610 GS for Level 20 basic K2 SAN” on page 42

NH1 K2 Media Server (optional)

Dell 1950 “Dell 1950 NH1 for online K2 SAN” on page 46

Dell R610 “Dell R610 NH1 for online K2 SAN” on page 47

NH1-10GE K2 Media Server (optional)

Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49

Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50

K2 RAID Level 20 K2 RAID “K2 RAID for Level 20 basic K2 SAN” on page 59

RAID PrimaryChassis

RAID Expansion Chassis (optional)

K2 Media Server

Gigabit Ethernet Switch

Control

Media

Control

Media

Co

ntro

l

FT

P

Me

dia

Me

dia

Control point PC

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

K2 clients

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 MEDIA SERVER

Control

Co

ntro

l

FTP/streaming

Control

Media

Fibre Channel

NH Server(optional)

K2 MEDIA SERVER

ControlFTP

K2 Storage Cabling Guide 01 April 2010

Page 15: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Level 20 Redundant K2 SAN

Level 20 Redundant K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

Multiple NH servers must be of the same type, either all NH1-10GE or all NH1.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for redundant K2 SAN” on page 25

K2 Summit Production Client

“K2 Summit Production Client for redundant K2 SAN” on page 26

Gigabit Ethernet Switch HP 2900 series “29xx HP GigE switch for redundant K2 SAN” on page 30

K2 Media Server Dell 1950 “Dell 1950 GS for Level 20 redundant K2 SAN” on page 35

Dell R610 “Dell R610 GS for Level 20 redundant K2 SAN” on page 43

NH1 K2 Media Server (optional)

Dell 1950 “Dell 1950 NH1 for online K2 SAN” on page 46

Dell R610 “Dell R610 NH1 for online K2 SAN” on page 47

NH1-10GE K2 Media Server (optional)

Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49

Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50

K2 RAID Level 20 K2 RAID “K2 RAID for Level 20 redundant K2 SAN” on page 60

RAID PrimaryChassis

RAID Expansion Chassis (optional)

K2 MediaServers

NH Servers(optional)

A B

BA

Gigabit EthernetSwitches

Fibre Channel

Co

ntro

l B

Me

dia

B

Co

ntro

l A

Me

dia

A

Co

ntro

l A

Me

dia

A

Co

ntro

l B

Me

dia

B

Co

ntro

l

FT

P

Me

dia

Me

dia

Co

ntro

lF

TP

Me

dia

Media

Control point PC

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

K2 clients

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 MEDIA SERVER K2 MEDIA SERVER

K2 MEDIA SERVER

ControlISLs

Co

ntro

l

Co

ntro

l

FTP/streaming

Co

ntro

l B

Me

dia

B

Co

ntro

l A

Media A

MEDIA SERVER

Fibre Channel

Control

FTP

Contro

lFT

P

01 April 2010 K2 Storage Cabling Guide 15

Page 16: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

16

Chapter 1 Start with the K2 storage system diagram

Level 30 Basic K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

Multiple NH servers must be of the same type, either all NH1-10GE or all NH1.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for basic K2 SAN” on page 24

K2 Summit Production Client

“K2 Summit Production Client for basic K2 SAN” on page 25

Gigabit Ethernet Switch HP 2900 series “29xx HP GigE switch for basic K2 SAN” on page 29

K2 Media Server Dell 2950 “Dell 2950 LS for basic K2 SAN” on page 41

Dell R710 “Dell R710 LS for basic K2 SAN” on page 44

NH1 K2 Media Server (optional)

Dell 1950 “Dell 1950 NH1 for online K2 SAN” on page 46

Dell R610 “Dell R610 NH1 for online K2 SAN” on page 47

NH1-10GE K2 Media Server (optional)

Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49

Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50

K2 RAID Level 30 K2 RAID “K2 RAID for Level 30 basic K2 SAN” on page 61

RAID PrimaryChassis

RAID Expansion Chassis (optional)

K2 Media Server

Gigabit Ethernet Switch

Control

Media

Control

Media

Co

ntro

l

FT

P

Me

dia

Me

dia

Me

dia

Me

dia

Control point PC

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

K2 clients

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 MEDIA SERVER

Control

Co

ntro

l

FTP/streaming

Control

Media

Fibre Channel

NH Server(optional)

K2 MEDIA SERVER

ControlFTP

K2 Storage Cabling Guide 01 April 2010

Page 17: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Level 30 Redundant K2 SAN

Level 30 Redundant K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

Multiple NH servers must be of the same type, either all NH1-10GE or all NH1.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for redundant K2 SAN” on page 25

K2 Summit Production Client

“K2 Summit Production Client for redundant K2 SAN” on page 26

Gigabit Ethernet Switch HP 2900 series “29xx HP GigE switch for redundant K2 SAN” on page 30

K2 Media Server Dell 2950 “Dell 2950 LS for redundant K2 SAN” on page 41

Dell R710 “Dell R710 LS for redundant K2 SAN” on page 45

NH1 K2 Media Server (optional)

Dell 1950 “Dell 1950 NH1 for online K2 SAN” on page 46

Dell R610 “Dell R610 NH1 for online K2 SAN” on page 47

NH1-10GE K2 Media Server (optional)

Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49

Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50

K2 RAID Level 30 K2 RAID “K2 RAID for Level 30 redundant K2 SAN” on page 62

RAID PrimaryChassis

RAID Expansion Chassis (optional)

K2 MediaServers

NH Servers(optional)

A B

BA

Gigabit EthernetSwitches

Fibre Channel

Co

ntro

l B

Me

dia

B

Co

ntro

l A

Me

dia

A

Co

ntro

l A

Me

dia

A

Co

ntro

l B

Me

dia

B

Co

ntro

l

FT

P

Me

dia

Me

dia

Me

dia

Me

dia

Co

ntro

lF

TP

Me

dia

Media

Me

dia

Media

Control point PC

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

K2 clients

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 MEDIA SERVER K2 MEDIA SERVER

K2 MEDIA SERVER

ControlISLs

Co

ntro

l

Co

ntro

l

FTP/streamingC

on

trol B

Me

dia

B

Co

ntro

l A

Media A

MEDIA SERVER

Fibre Channel

Control

FTP

Contro

lFT

P

01 April 2010 K2 Storage Cabling Guide 17

Page 18: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

18

Chapter 1 Start with the K2 storage system diagram

Level 35 Basic K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for basic K2 SAN” on page 24

K2 Summit Production Client

“K2 Summit Production Client for basic K2 SAN” on page 25

Gigabit Ethernet Switch HP 2900 series “29xx HP GigE switch for basic K2 SAN” on page 29

K2 Media Server Dell 1950 “Dell 1950 GS for Level 35 basic K2 SAN” on page 36

Dell R610 “Dell R610 GS for Level 35 basic K2 SAN” on page 43

NH1-10GE K2 Media Server (optional)

Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49

Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50

K2 RAID Level 35 K2 RAID “K2 RAID for Level 35 basic K2 SAN” on page 63

L30 RAID PrimaryChassis

RAID Expansion Chassis (optional)

GS K2 Media Servers

21

Gigabit Ethernet Switch

Control

Media

Control

Media

Co

ntro

lM

ed

iaM

ed

ia

Control point PC

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

K2 clients

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 MEDIA SERVER

Co

ntro

l

FT

P

Me

dia

Me

dia

K2 MEDIA SERVER

Control

Co

ntro

l

FTP/streaming

Control

Media

Fibre Channel

NH1-10GE Server(optional)

K2 MEDIA SERVER

ControlFTP

K2 Storage Cabling Guide 01 April 2010

Page 19: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Level 35 Redundant K2 SAN

Level 35 Redundant K2 SAN

This manual documents the default GigE switch configuration. Other configurations are available, depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client for redundant K2 SAN” on page 25

K2 Summit Production Client

“K2 Summit Production Client for redundant K2 SAN” on page 26

Gigabit Ethernet Switch HP 2900 series “29xx HP GigE switch for redundant K2 SAN” on page 30

K2 Media Server Dell 1950 “Dell 1950 GS for Level 35 redundant K2 SAN” on page 37

Dell R610 “Dell R610 GS for Level 35 redundant K2 SAN” on page 44

NH1-10GE K2 Media Server (optional)

Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49

Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50

K2 RAID Level 35 K2 RAID “K2 RAID for Level 35 redundant K2 SAN” on page 64

NH1-10GE Server (optional)

K2 MEDIA SERVER

ControlFTP

Fibre Channel Fibre Channel

L30 RAID PrimaryChassis

RAID Expansion Chassis (optional)

1A

A B

2A 1B 2B

Gigabit Ethernet Switches

Control A

Media A

Control A

Control B

Media A

Media B

Control B

Media B

ControlF

TP

Media

Media

Control

Media

Media

ControlF

TP

Media

Media

Control

Media

Media

Control point PC

! K2 SAS STORAGE

K2 clients

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 SUMMITPRODUCTION CLIENT

K2 MEDIA SERVER K2 MEDIA SERVER K2 MEDIA SERVER K2 MEDIA SERVER

ControlISLs

Control

Control

FTP/streaming

Control B

Media B

Control A

Media A

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

GS K2 MediaServers

01 April 2010 K2 Storage Cabling Guide 19

Page 20: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

20

Chapter 1 Start with the K2 storage system diagram

Nearline 10 Basic K2 SAN

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

Gigabit Ethernet Switch HP 2900 series “29xx HP GigE switch for basic nearline K2 SAN” on page 30

NH1 K2 Media Server Dell 1950 “Dell 1950 NH1 for basic nearline K2 SAN” on page 46

Dell R610 “Dell R610 NH1 for basic nearline K2 SAN” on page 47

NH1-10GE K2 Media Server

Dell 1950 “Dell 1950 NH1-10GE for basic nearline K2 SAN” on page 49

Dell R610 “Dell R610 NH1-10GE for basic nearline K2 SAN” on page 50

K2 RAID Level 10 K2 RAID “K2 RAID for Nearline 10 basic K2 SAN” on page 65

Co

ntro

l

RAID Chassis(SATA drives)

RAID Expansion Chassis(SATA drives)

NH K2 MediaServer

Gigabit EthernetSwitch

Fibre Channelconnection

Co

ntro

l

FT

P

Control point PC

! K2 SATA STORAGE

! K2 SATA STORAGE

! K2 SATA STORAGE

! K2 SATA STORAGE

K2 MEDIA SERVER

Control

FTP to/from online system

K2 Storage Cabling Guide 01 April 2010

Page 21: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Nearline 10 Redundant K2 SAN

Nearline 10 Redundant K2 SAN

Redundant NH servers must be of the same type, either both NH1-10GE or both NH1.

To cable this K2 SAN device…

Of this model or platform…

Turn to these instructions:

Gigabit Ethernet Switch HP 2900 series “29xx HP GigE switch for redundant nearline K2 SAN” on page 31

NH1 K2 Media Server Dell 1950 “Dell 1950 NH1 for redundant nearline K2 SAN” on page 47

Dell R610 “Dell R610 NH1 for redundant nearline K2 SAN” on page 48

NH1-10GE K2 Media Server

Dell 1950 “Dell 1950 NH1-10GE for redundant nearline K2 SAN” on page 50

Dell R610 “Dell R610 NH1-10GE for redundant nearline K2 SAN” on page 51

K2 RAID Level 10 K2 RAID “K2 RAID for Nearline 10 redundant K2 SAN” on page 66

ISLs

Co

ntro

l

Co

ntro

l

RAID Chassis(SAS drives)

RAID Expansion Chassis(SATA drives)

NH K2 MediaServers

Gigabit EthernetSwitches

Fibre Channelconnections

Co

ntro

l

FT

P

Co

ntro

lF

TP

Control point PC

! K2 SATA STORAGE

! K2 SATA STORAGE

! K2 SATA STORAGE

! K2 SATA STORAGE

K2 MEDIA SERVERK2 MEDIA SERVER

Control

FTP to/from online system

ISLsA

A

B

B

01 April 2010 K2 Storage Cabling Guide 21

Page 22: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

22

Chapter 1 Start with the K2 storage system diagram

K2 client with direct-connect storage

To cable this K2 device… Of this model or platform…

Turn to these instructions:

K2 client K2 Media Client, including SDA-00, SD-00, and HD-00.

“K2 Media Client with direct-connect storage” on page 26

K2 Summit Production Client

“K2 Summit Production Client with direct-connect storage” on page 27

K2 RAID Level 30 K2 RAID “K2 RAID for K2 client direct-connect storage” on page 67

RAID PrimaryChassis

RAID Expansion Chassis (optional)

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

! K2 SAS STORAGE

K2 clientK2 SUMMIT PRODUCTION

CLIENT

FibreChannel

FibreChannel

K2 Storage Cabling Guide 01 April 2010

Page 23: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Chapter 2

Cable K2 devices

As directed by the system diagram for your K2 storage, cable the individual devices of your K2 system using the instructions in the following sections.

• “Cable K2 client” on page 24

• “Cable Gigabit Ethernet switch” on page 28

• “Cable K2 Media Server” on page 32

• “Cable NH1 K2 Media Server” on page 46

• “Cable NH1-10GE K2 Media Server” on page 49

• “Cable K2 RAID” on page 52

01 April 2010 K2 Storage Cabling Guide 23

Page 24: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

24

Chapter 2 Cable K2 devices

Cable K2 clientAs directed by the system diagram for your K2 storage, cable the K2 client devices using the instructions in this section.

• “K2 Media Client for basic K2 SAN” on page 24

• “K2 Media Client for redundant K2 SAN” on page 25

• “K2 Summit Production Client for basic K2 SAN” on page 25

• “K2 Summit Production Client for redundant K2 SAN” on page 26

• “K2 Media Client with direct-connect storage” on page 26

• “K2 Summit Production Client with direct-connect storage” on page 27

K2 Media Client for basic K2 SANThese cabling instructions apply to the following:

• K2 Media Client on a basic (non-redundant) K2 SAN

K2 Media Client model SD-00 is shown. Other models have similar connections. Refer to each model’s K2 Media Client Quick Start Guide for additional cabling details.

RS-422Port 3Port 4 SCSI

RS-422Port 1Port 2

10Bt100Bt

1000Bt

PushPush

PushPush

PushPush

GPIO !SDI CH 1IN OUT

SDI CH 2IN OUT

SDI CH 3IN OUT

SDI CH 4IN OUT

OUT OUT OUT OUT

INLTC CH 1 LTC CH 2 LTC CH 3 LTC CH 4 UNUSED UNUSED

IN IN IN

AES/EBU CH 1IN OUT1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

AES/EBU CH 2IN OUT

AES/EBU CH 3IN OUT

AES/EBU CH 4IN OUT

REFCOMPOSITE LOOP

THRU

To control porton GigE switch

To media (iSCSI) porton GigE switch

K2 Storage Cabling Guide 01 April 2010

Page 25: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2 Media Client for redundant K2 SAN

K2 Media Client for redundant K2 SANThese cabling instructions apply to the following:

• K2 Media Client on a redundant K2 SAN

K2 Media Client model SD-00 is shown. Other models have similar connections. Refer to each model’s K2 Media Client Quick Start Guide for additional cabling details.

K2 Summit Production Client for basic K2 SANThese cabling instructions apply to the following:

• K2 Summit Production Client on a basic (non-redundant) K2 SAN

Refer to the K2 Summit Production Client Quick Start Guide for additional cabling details.

RS-422Port 3Port 4 SCSI

RS-422Port 1Port 2

10Bt100Bt

1000Bt

PushPush

PushPush

PushPush

GPIO !SDI CH 1IN OUT

SDI CH 2IN OUT

SDI CH 3IN OUT

SDI CH 4IN OUT

OUT OUT OUT OUT

INLTC CH 1 LTC CH 2 LTC CH 3 LTC CH 4 UNUSED UNUSED

IN IN IN

AES/EBU CH 1IN OUT1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

AES/EBU CH 2IN OUT

AES/EBU CH 3IN OUT

AES/EBU CH 4IN OUT

REFCOMPOSITE LOOP

THRU

To control porton GigE switch A

To media (iSCSI) porton GigE switch A

To control porton GigE switch B

To media (iSCSI) porton GigE switch B

C1 C2 C3 C4

!

OK

~AC

!

OK

~AC

SDI IN1 SDI OUT1 SDI OUT2 LTC I/O

AES AUDIO RS422

SDI OUT1 SDI OUT2

USB/1394 100BT/1000BT

GPI

VGA REF. LOOP THROUGH

AES AUDIO RS422

LTC I/OSDI IN2 SDI IN3 SDI IN1 SDI IN2 SDI IN3 SDI IN1 SDI OUT1 SDI OUT2 LTC I/O

AES AUDIO RS422

SDI OUT1 SDI OUT2

AES AUDIO RS422

LTC I/OSDI IN2 SDI IN3 SDI IN1 SDI IN2 SDI IN3

To control porton GigE switch

To media (iSCSI) porton GigE switch

01 April 2010 K2 Storage Cabling Guide 25

Page 26: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

26

Chapter 2 Cable K2 devices

K2 Summit Production Client for redundant K2 SANThese cabling instructions apply to the following:

• K2 Summit Production Client on a redundant K2 SAN

Refer to the K2 Summit Production Client Quick Start Guide for additional cabling details.

K2 Media Client with direct-connect storageThese cabling instructions apply to the following:

• K2 Media Client with direct-connect K2 RAID storage

Refer to the K2 Media Client System Guide for additional information about direct-connect storage.

K2 Media Client model SD-00 is shown. Other models have similar connections. Refer to each model’s K2 Media Client Quick Start Guide for additional cabling details.

C1 C2 C3 C4

!

OK

~AC

!

OK

~AC

SDI IN1 SDI OUT1 SDI OUT2 LTC I/O

AES AUDIO RS422

SDI OUT1 SDI OUT2

USB/1394 100BT/1000BT

GPI

VGA REF. LOOP THROUGH

AES AUDIO RS422

LTC I/OSDI IN2 SDI IN3 SDI IN1 SDI IN2 SDI IN3 SDI IN1 SDI OUT1 SDI OUT2 LTC I/O

AES AUDIO RS422

SDI OUT1 SDI OUT2

AES AUDIO RS422

LTC I/OSDI IN2 SDI IN3 SDI IN1 SDI IN2 SDI IN3

To control porton GigE switch A

To control porton GigE switch B

To media (iSCSI) porton GigE switch A

To media (iSCSI) porton GigE switch B

RS-422Port 3Port 4 SCSI

RS-422Port 1Port 2

10Bt100Bt

1000Bt

PushPush

PushPush

PushPush

GPIO !SDI CH 1IN OUT

SDI CH 2IN OUT

SDI CH 3IN OUT

SDI CH 4IN OUT

OUT OUT OUT OUT

INLTC CH 1 LTC CH 2 LTC CH 3 LTC CH 4 UNUSED UNUSED

IN IN IN

AES/EBU CH 1IN OUT1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

1-2

3-4

AES/EBU CH 2IN OUT

AES/EBU CH 3IN OUT

AES/EBU CH 4IN OUT

REFCOMPOSITE LOOP

THRU

K2 Media Client

Fibre Channel card can be in a different location than shown, but connections are similar.

To K2 RAIDController

To K2 RAIDController

K2 Storage Cabling Guide 01 April 2010

Page 27: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2 Summit Production Client with direct-connect storage

K2 Summit Production Client with direct-connect storageThese cabling instructions apply to the following:

• K2 Summit Production Client with direct-connect K2 RAID storage

Refer to the K2 System Guide for additional information about direct-connect storage.

Refer to the K2 Summit Production Client Quick Start Guide for additional cabling details.

C1 C2 C3 C4

!

OK

~AC

!

OK

~AC

SDI IN1 SDI OUT1 SDI OUT2 LTC I/O

AES AUDIO RS422

SDI OUT1 SDI OUT2

USB/1394 100BT/1000BT

GPI

VGA REF. LOOP THROUGH

AES AUDIO RS422

LTC I/OSDI IN2 SDI IN3 SDI IN1 SDI IN2 SDI IN3 SDI IN1 SDI OUT1 SDI OUT2 LTC I/O

AES AUDIO RS422

SDI OUT1 SDI OUT2

AES AUDIO RS422

LTC I/OSDI IN2 SDI IN3 SDI IN1 SDI IN2 SDI IN3

K2 Summit Production Client

To K2 RAIDController

To K2 RAIDController

01 April 2010 K2 Storage Cabling Guide 27

Page 28: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

28

Chapter 2 Cable K2 devices

Cable Gigabit Ethernet switchAs directed by the system diagram for your K2 SAN’s level, cable the switch or switches for your K2 SAN using the instructions in this section.

• “3400cl HP GigE switch for basic K2 SAN” on page 28

• “3400cl HP GigE switch for redundant K2 SAN” on page 29

• “29xx HP GigE switch for basic K2 SAN” on page 29

• “29xx HP GigE switch for redundant K2 SAN” on page 30

• “29xx HP GigE switch for basic nearline K2 SAN” on page 30

• “29xx HP GigE switch for redundant nearline K2 SAN” on page 31

3400cl HP GigE switch for basic K2 SANThese cabling instructions apply to the following:

• HP 3400cl series Gigabit Ethernet switch on a basic (non-redundant) online K2 SAN.

To the media ports make one connection from each K2 Media Client or other iSCSI client and two connections from the media server.

To the control ports make a connection from each K2 Media Client or other iSCSI client, from the media server, from the RAID storage chassis, and from the control point PC.

Media Ports

Control Ports

1 - 19 odd

2 - 20 even

K2 Storage Cabling Guide 01 April 2010

Page 29: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

3400cl HP GigE switch for redundant K2 SAN

3400cl HP GigE switch for redundant K2 SANThese cabling instructions apply to the following:

• HP 3400cl series Gigabit Ethernet switch on a redundant online K2 SAN.

To the media ports on switch A, make one media connection from each K2 Media Client or other iSCSI client and make two connections from media server A.

To the media ports on switch B, make the second media connection from each K2 Media Client or other iSCSI client and make two connections from media server B.

To the control ports on switch A, make one control connection from each K2 Media Client or other iSCSI client, from media server A, from the RAID storage chassis, and from the control point PC.

To the control ports on switch B, make the second control connection from each K2 Media Client or other iSCSI client and the control connection from media server B.

Interconnect switch A and switch B with two 10 Gig ISLs.

29xx HP GigE switch for basic K2 SANThese cabling instructions apply to the following:

• HP 29xx series Gigabit Ethernet switch on a basic (non-redundant) online K2 SAN.

NOTE: NH1-10GE server not supported on Level 10 K2 SAN.

Media Ports

Control Ports

1 - 19 odd

2 - 20 evenISLs

Control ports

Media (iSCSI) ports

10 Gig connections to rear of switch for optional NH1-10GE servers

Control ports are for control connections from K2 clients, Aurora products, automation, etc., as well as FTP connections from Grass Valley and 3rd party systems.

01 April 2010 K2 Storage Cabling Guide 29

Page 30: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

30

Chapter 2 Cable K2 devices

29xx HP GigE switch for redundant K2 SANThese cabling instructions apply to the following:

• HP 29xx series Gigabit Ethernet switch on a basic (non-redundant) online K2 SAN.

NOTE: NH1-10GE server not supported on Level 10 K2 SAN.

29xx HP GigE switch for basic nearline K2 SANThese cabling instructions apply to the following:

• HP 29xx series Gigabit Ethernet switch on a basic (non-redundant) nearline K2 SAN.

Control ports

Media (iSCSI) ports

Control ports

Media (iSCSI) ports

B

A

Inter-Switch Links (ISLs)

Control ports are for control connections from K2 clients, Aurora products, automation, etc., as well as FTP connections from Grass Valley and 3rd party systems.

10 Gig connections to rear of switch for optional NH1-10GE servers

10 Gig FTP connection to rear of switch for NH1-10GE server

Ports are for control connections as well as FTP connections from Grass Valley and 3rd party systems.

K2 Storage Cabling Guide 01 April 2010

Page 31: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

29xx HP GigE switch for redundant nearline K2 SAN

29xx HP GigE switch for redundant nearline K2 SANThese cabling instructions apply to the following:

• HP 29xx series Gigabit Ethernet switch on a redundant nearline K2 SAN.

B

A

Inter-Switch Links (ISLs)10 Gig FTP connections to rear of switch for NH1-10GE servers

Ports are for control connections as well as FTP connections from Grass Valley and 3rd party systems.

01 April 2010 K2 Storage Cabling Guide 31

Page 32: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

32

Chapter 2 Cable K2 devices

Cable K2 Media ServerAs directed by the system diagram for your K2 SAN’s level, cable the K2 Media Server or Servers for your K2 SAN using the instructions in this section.

• “Dell 2850 for basic K2 SAN” on page 33

• “Dell 2850 for redundant K2 SAN” on page 33

• “Dell 1950 GS for Level 10 basic K2 SAN” on page 34

• “Dell 1950 GS for Level 10 redundant K2 SAN” on page 34

• “Dell 1950 GS for Level 20 basic K2 SAN” on page 35

• “Dell 1950 GS for Level 20 redundant K2 SAN” on page 35

• “Dell 1950 GS for Level 35 basic K2 SAN” on page 36

• “Dell 1950 GS for Level 35 redundant K2 SAN” on page 37

• “Dell 2950 for basic K2 SAN” on page 38

• “Dell 2950 for redundant K2 SAN” on page 38

• “Dell 2950 for Level 3 basic K2 SAN” on page 39

• “Dell 2950 for Level 3 redundant K2 SAN” on page 40

• “Dell 2950 LS for basic K2 SAN” on page 41

• “Dell 2950 LS for redundant K2 SAN” on page 41

• “Dell R610 GS for Level 10 basic K2 SAN” on page 42

• “Dell R610 GS for Level 10 redundant K2 SAN” on page 42

• “Dell R610 GS for Level 20 basic K2 SAN” on page 42

• “Dell R610 GS for Level 20 redundant K2 SAN” on page 43

• “Dell R610 GS for Level 35 basic K2 SAN” on page 43

• “Dell R610 GS for Level 35 redundant K2 SAN” on page 44

• “Dell R710 LS for basic K2 SAN” on page 44

• “Dell R710 LS for redundant K2 SAN” on page 45

K2 Storage Cabling Guide 01 April 2010

Page 33: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Dell 2850 for basic K2 SAN

Dell 2850 for basic K2 SANThese cabling instructions apply to the following:

• Dell 2850 PowerEdge Server on a basic (non-redundant) online K2 SAN.

Connect the two iSCSI interface adapters to media ports on the GigE switch.

Connect the motherboard GigE port 1 and GigE port 2 to control ports on the GigE switch.

Connect one of the Fibre Channel ports to the RAID storage device.

Dell 2850 for redundant K2 SANThese cabling instructions apply to the following:

• Dell 2850 PowerEdge Server on a redundant online K2 SAN.

Connect the two iSCSI interface adapters to media ports on the GigE switch.

Connect the motherboard GigE port 1 and GigE port 2 to control ports on the GigE switch.

Connect one of the Fibre Channel ports to the RAID storage device.

Make a direct connection between the serial ports of the two redundant servers. For Level 3 redundant, connect server 1A to server 1B, and connect server 2A to server 2B.

iSCSI interface

PowerKeyboard/Mouse

GigE

3

2

1 Fibre Channel

VGA monitor

GigE

(FTP) (control)

ports (GigE media)

port 1(USB)Serial port

port 2

iSCSI interface

PowerKeyboard/Mouse

GigE

3

2

1 Fibre Channel

VGA monitor

GigE

(FTP) (control)

ports (GigE media)

port 1(USB)Serial port

port 2

01 April 2010 K2 Storage Cabling Guide 33

Page 34: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

34

Chapter 2 Cable K2 devices

Dell 1950 GS for Level 10 basic K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server on a Level 10 basic (non-redundant) K2 SAN.

Dell 1950 GS for Level 10 redundant K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server on a Level 10 redundant K2 SAN.

1 2

Gb 2Gb 1

To media (iSCSI) port on GigE switch

Fibre Channelto RAID controller

To control port on GigE switch

FTP: To control port on GigE switch

1 2

Gb 2Gb 1

1 2

Gb 2Gb 1

A

B

To media (iSCSI) port on GigE switch A

Fibre Channelto RAID controller 0

To media (iSCSI) port on GigE switch B

Fibre Channelto RAID controller 1

To control port on GigE switch A

FTP: To control port on GigE switch A

To control port on GigE switch B

FTP: To control port on GigE switch B

Heartbeatcable

(serial)

K2 Storage Cabling Guide 01 April 2010

Page 35: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Dell 1950 GS for Level 20 basic K2 SAN

Dell 1950 GS for Level 20 basic K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server on a Level 20 basic (non-redundant) K2 SAN.

Dell 1950 GS for Level 20 redundant K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server on a Level 20 redundant K2 SAN.

1 2

Gb 2Gb 1

To media (iSCSI) ports on GigE switch

Fibre Channelto RAID controller

To control port on GigE switch

FTP: To control port on GigE switch

1 2

Gb 2Gb 1

1 2

Gb 2Gb 1

A

B

To media (iSCSI) ports on GigE switch A

Fibre Channelto RAID controller 0

To media (iSCSI) ports on GigE switch B

Fibre Channelto RAID controller 1

To control port on GigE switch A

FTP: To control port on GigE switch A

To control port on GigE switch B

FTP: To control port on GigE switch B

Heartbeatcable

(serial)

01 April 2010 K2 Storage Cabling Guide 35

Page 36: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

36

Chapter 2 Cable K2 devices

Dell 1950 GS for Level 35 basic K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server on a Level 35 basic (non-redundant) K2 SAN.

1 2

Gb 2Gb 1

To control port on GigE switch

FTP: To control port on GigE switch.Do not use if optional NH serveris present to handle FTP traffic.

1 2

Gb 2Gb 1

1

2

To media (iSCSI) ports on GigE switch

To control port on GigE switch

Media File System ServerMetadata (database) ServeriSCSI Bridge

Roles:

iSCSI BridgeNAS Server(FTP Server if NH server is not present)

Roles:

Fibre Channelto RAID controller

To media (iSCSI) ports on GigE switch

Fibre Channelto RAID controller

K2 Storage Cabling Guide 01 April 2010

Page 37: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Dell 1950 GS for Level 35 redundant K2 SAN

Dell 1950 GS for Level 35 redundant K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server on a Level 35 redundant K2 SAN.

1 2

Gb 2Gb 1

1 2

Gb 2Gb 1

1 2

Gb 2Gb 1

To control port on GigE switch A

FTP: To control port on GigE switch A.Do not use if optional NH serveris present to handle FTP traffic.

1 2

Gb 2Gb 1

1A

2A

1B

2B

Heartbeatcable(serial)

To media (iSCSI) ports on GigE switch A

To control port on GigE switch A

Media File System ServerMetadata (database) ServeriSCSI Bridge

Roles:

Media File System ServerMetadata (database) ServeriSCSI Bridge

Roles:

iSCSI BridgeNAS Server(FTP Server if NH server is not present)

Roles:

Fibre Channelto RAID controller

To media (iSCSI) ports on GigE switch B

To control port on GigE switch B

Fibre Channelto RAID controller

To media (iSCSI) ports on GigE switch A

Fibre Channelto RAID controller

To control port on GigE switch B

FTP: To control port on GigE switch B.Do not use if optional NH serveris present to handle FTP traffic.

iSCSI BridgeNAS Server(FTP Server if NH server is not present)

Roles:

To media (iSCSI) ports on GigE switch B

Fibre Channelto RAID controller

01 April 2010 K2 Storage Cabling Guide 37

Page 38: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

38

Chapter 2 Cable K2 devices

Dell 2950 for basic K2 SANThese cabling instructions apply to the following:

• Dell 2950 PowerEdge Server with two iSCSI interface adapters (TOEs) on a basic (non-redundant) online K2 SAN.

Dell 2950 for redundant K2 SANThese cabling instructions apply to the following:

• Dell 2950 PowerEdge Server with two iSCSI interface adapters (TOEs) on a redundant online K2 SAN.

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

Fibre Channelto RAID controller

To control port on GigE switch

FTP: To control port on GigE switch

To media (iSCSI) ports on GigE switch

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

Fibre Channelto RAID controller

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

A

To control port on GigE switch A

FTP: To control port on GigE switch A

To control port on GigE switch B

FTP: To control port on GigE switch B

B

Heartbeatcable(serial)

To media (iSCSI) ports on GigE switch A

To media (iSCSI) ports on GigE switch B

Fibre Channelto RAID controller

K2 Storage Cabling Guide 01 April 2010

Page 39: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Dell 2950 for Level 3 basic K2 SAN

Dell 2950 for Level 3 basic K2 SANThese cabling instructions apply to the following:

• Dell 2950 PowerEdge Server with two iSCSI interface adapters (TOEs) on a Level 3 basic (non-redundant) K2 SAN.

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

Fibre Channelto RAID controller

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

Media File System ServerMedia Database ServeriSCSI Bridge

Roles:

FTP ServeriSCSI BridgeNAS Server

Roles:

To control port on GigE switch

1

2

To control port on GigE switch

FTP: To control port on GigE switch

To media (iSCSI) ports on GigE switch

To media (iSCSI) ports on GigE switch

Fibre Channelto RAID controller

01 April 2010 K2 Storage Cabling Guide 39

Page 40: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

40

Chapter 2 Cable K2 devices

Dell 2950 for Level 3 redundant K2 SANThese cabling instructions apply to the following:

• Dell 2950 PowerEdge Server with two iSCSI interface adapters (TOEs) on a Level 3 redundant K2 SAN.

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

Fibre Channelto RAID controller

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

Fibre Channelto RAID controller

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

To control port on GigE switch A

FTP: To control port on GigE switch A

To control port on GigE switch B

FTP: To control port on GigE switch B

Fibre Channelto RAID controller

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

1A

2A

1B

2B

Heartbeatcable(serial)

To media (iSCSI) ports on GigE switch A

To media (iSCSI) ports on GigE switch A

To media (iSCSI) ports on GigE switch B

To media (iSCSI) ports on GigE switch B

To control port on GigE switch A

Media File System ServerMedia Database ServeriSCSI Bridge

Roles:

Media File System ServerMedia Database ServeriSCSI Bridge

Roles:

FTP ServeriSCSI BridgeNAS Server

Roles:

FTP ServeriSCSI BridgeNAS Server

Roles:

To control port on GigE switch B

Fibre Channelto RAID controller

K2 Storage Cabling Guide 01 April 2010

Page 41: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Dell 2950 LS for basic K2 SAN

Dell 2950 LS for basic K2 SANThese cabling instructions apply to the following:

• Dell 2950 PowerEdge Server with four iSCSI interface adapters (TOEs) on a basic (non-redundant) online K2 SAN.

Dell 2950 LS for redundant K2 SANThese cabling instructions apply to the following:

• Dell 2950 PowerEdge Server with four iSCSI interface adapters (TOEs) on a redundant online K2 SAN.

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

To media (iSCSI) ports on GigE switch

Fibre Channelto RAID controller

To control port on GigE switch

FTP: To control port on GigE switch

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

PCI 1

PCI 2

PCI 3

Gb 1 Gb 2

A

B

To media (iSCSI) ports on GigE switch A

Fibre Channelto RAID controller 0

To media (iSCSI) ports on GigE switch B

Fibre Channelto RAID controller 1

To control port on GigE switch A

FTP: To control port on GigE switch A

To control port on GigE switch B

FTP: To control port on GigE switch B

Heartbeatcable

(serial)

01 April 2010 K2 Storage Cabling Guide 41

Page 42: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

42

Chapter 2 Cable K2 devices

Dell R610 GS for Level 10 basic K2 SANThese cabling instructions apply to the following:

• Dell R610 PowerEdge Server on a Level 10 basic (non-redundant) K2 SAN.

Dell R610 GS for Level 10 redundant K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server on a Level 10 redundant K2 SAN.

Dell R610 GS for Level 20 basic K2 SANThese cabling instructions apply to the following:

• Dell R610 PowerEdge Server on a Level 20 basic (non-redundant) K2 SAN.

To media (iSCSI) port on GigE switch

Fibre Channelto RAID controller

To control port on GigE switch

FTP: To control port on GigE switch

A

B

To media (iSCSI) port on GigE switch A

Fibre Channelto RAID controller 0

To media (iSCSI) port on GigE switch B

Fibre Channelto RAID controller 1

To control port on GigE switch A

FTP: To control port on GigE switch A

To control port on GigE switch B

FTP: To control port on GigE switch B

Heartbeatcable

(serial)

To media (iSCSI) ports on GigE switch

Fibre Channelto RAID controller

To control port on GigE switch

FTP: To control port on GigE switch

K2 Storage Cabling Guide 01 April 2010

Page 43: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Dell R610 GS for Level 20 redundant K2 SAN

Dell R610 GS for Level 20 redundant K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server on a Level 20 redundant K2 SAN.

Dell R610 GS for Level 35 basic K2 SANThese cabling instructions apply to the following:

• Dell R610 PowerEdge Server on a Level 35 basic (non-redundant) K2 SAN.

A

B

To media (iSCSI) ports on GigE switch A

Fibre Channelto RAID controller 0

To media (iSCSI) ports on GigE switch B

Fibre Channelto RAID controller 1

To control port on GigE switch A

FTP: To control port on GigE switch A

To control port on GigE switch B

FTP: To control port on GigE switch B

Heartbeatcable

(serial)

To control port on GigE switch

FTP: To control port on GigE switch.Do not use if optional NH serveris present to handle FTP traffic.

1

2

To media (iSCSI) ports on GigE switch

To control port on GigE switch

Media File System ServerMetadata (database) ServeriSCSI Bridge

Roles:

iSCSI BridgeNAS Server(FTP Server if NH server is not present)

Roles:

Fibre Channelto RAID controller

To media (iSCSI) ports on GigE switch

Fibre Channelto RAID controller

01 April 2010 K2 Storage Cabling Guide 43

Page 44: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

44

Chapter 2 Cable K2 devices

Dell R610 GS for Level 35 redundant K2 SANThese cabling instructions apply to the following:

• Dell R610 PowerEdge Server on a Level 35 redundant K2 SAN.

Dell R710 LS for basic K2 SANThese cabling instructions apply to the following:

• Dell R710 PowerEdge Server on a basic (non-redundant) online K2 SAN.

To control port on GigE switch A

FTP: To control port on GigE switch A.Do not use if optional NH serveris present to handle FTP traffic.

1A

2A

1B

2B

Heartbeatcable(serial)

To media (iSCSI) ports on GigE switch A

To control port on GigE switch A

Media File System ServerMetadata (database) ServeriSCSI Bridge

Roles:

Media File System ServerMetadata (database) ServeriSCSI Bridge

Roles:

iSCSI BridgeNAS Server(FTP Server if NH server is not present)

Roles:

Fibre Channelto RAID controller

To media (iSCSI) ports on GigE switch B

To control port on GigE switch B

Fibre Channelto RAID controller

To media (iSCSI) ports on GigE switch A

Fibre Channelto RAID controller

To control port on GigE switch B

FTP: To control port on GigE switch B.Do not use if optional NH serveris present to handle FTP traffic.

iSCSI BridgeNAS Server(FTP Server if NH server is not present)

Roles:

To media (iSCSI) ports on GigE switch B

Fibre Channelto RAID controller

To media (iSCSI) ports on GigE switch

Fibre Channelto RAID controller

To control port on GigE switch

FTP: To control port on GigE switch

K2 Storage Cabling Guide 01 April 2010

Page 45: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Dell R710 LS for redundant K2 SAN

Dell R710 LS for redundant K2 SANThese cabling instructions apply to the following:

• Dell R710 PowerEdge Server on a redundant online K2 SAN.

A

B

To media (iSCSI) ports on GigE switch A

Fibre Channelto RAID controller 0

To media (iSCSI) ports on GigE switch B

Fibre Channelto RAID controller 1

To control port on GigE switch A

FTP: To control port on GigE switch A

To control port on GigE switch B

FTP: To control port on GigE switch B

Heartbeatcable

(serial)

01 April 2010 K2 Storage Cabling Guide 45

Page 46: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

46

Chapter 2 Cable K2 devices

Cable NH1 K2 Media ServerAs directed by the system diagram for your K2 SAN’s level, cable the NH-1 K2 Media Server or Servers for your K2 SAN using the instructions in this section.

• “Dell 1950 NH1 for online K2 SAN” on page 46

• “Dell 1950 NH1 for basic nearline K2 SAN” on page 46

• “Dell 1950 NH1 for redundant nearline K2 SAN” on page 47

• “Dell R610 NH1 for online K2 SAN” on page 47

• “Dell R610 NH1 for redundant nearline K2 SAN” on page 48

Dell 1950 NH1 for online K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server NH1 on an online K2 SAN.

Dell 1950 NH1 for basic nearline K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server NH1 on a basic (non-redundant) nearline K2 SAN.

1 2

Gb 2Gb 1

Fibre Channelto RAID controller

To control porton GigE switch

FTP: To control porton GigE switch

1 2

Gb 2Gb 1

Fibre Channelto RAID controller

To control porton GigE switch

FTP: To control porton GigE switch

K2 Storage Cabling Guide 01 April 2010

Page 47: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Dell 1950 NH1 for redundant nearline K2 SAN

Dell 1950 NH1 for redundant nearline K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server NH1 on a redundant nearline K2 SAN.

Dell R610 NH1 for online K2 SANThese cabling instructions apply to the following:

• Dell R10 PowerEdge Server NH1 on an online K2 SAN.

Dell R610 NH1 for basic nearline K2 SANThese cabling instructions apply to the following:

• Dell R10 PowerEdge Server NH1 on a basic (non-redundant) nearline K2 SAN.

1 2

Gb 2Gb 1

Fibre Channel toRAID controller 1

Fibre Channel toRAID controller 0

To control porton GigE switch A

FTP: To control porton GigE switch A

1 2

Gb 2Gb 1

Fibre Channel toRAID controller 1

Fibre Channel toRAID controller 0

To control porton GigE switch B

FTP: To control porton GigE switch B

A

B

Fibre Channelto RAID controller

To control porton GigE switch

FTP: To control porton GigE switch

Fibre Channelto RAID controller

To control porton GigE switch

FTP: To control porton GigE switch

01 April 2010 K2 Storage Cabling Guide 47

Page 48: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

48

Chapter 2 Cable K2 devices

Dell R610 NH1 for redundant nearline K2 SANThese cabling instructions apply to the following:

• Dell R10 PowerEdge Server NH1 on a redundant nearline K2 SAN.

Fibre Channel toRAID controller 1

Fibre Channel toRAID controller 0

To control porton GigE switch A

FTP: To control porton GigE switch A

Fibre Channel toRAID controller 1

Fibre Channel toRAID controller 0

To control porton GigE switch B

FTP: To control porton GigE switch B

A

B

K2 Storage Cabling Guide 01 April 2010

Page 49: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Cable NH1-10GE K2 Media Server

Cable NH1-10GE K2 Media ServerAs directed by the system diagram for your K2 SAN’s level, cable the NH1-10GE K2 Media Server or Servers for your K2 SAN using the instructions in this section.

• “Dell 1950 NH1-10GE for online K2 SAN” on page 49

• “Dell 1950 NH1-10GE for basic nearline K2 SAN” on page 49

• “Dell 1950 NH1-10GE for redundant nearline K2 SAN” on page 50

• “Dell R610 NH1-10GE for online K2 SAN” on page 50

• “Dell R610 NH1-10GE for basic nearline K2 SAN” on page 50

• “Dell R610 NH1-10GE for redundant nearline K2 SAN” on page 51

Dell 1950 NH1-10GE for online K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server NH1-10GE on an online K2 SAN.

Dell 1950 NH1-10GE for basic nearline K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server NH1-10GE on a basic (non-redundant) nearline K2 SAN.

1 2

Gb 2Gb 1

FTP: To 10 Gig port on GigE switch

Fibre Channelto RAID controller

To control porton GigE switch

1 2

Gb 2Gb 1

To control porton GigE switch

FTP: To 10 Gig port on GigE switch

Fibre Channelto RAID controller

01 April 2010 K2 Storage Cabling Guide 49

Page 50: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

50

Chapter 2 Cable K2 devices

Dell 1950 NH1-10GE for redundant nearline K2 SANThese cabling instructions apply to the following:

• Dell 1950 PowerEdge Server NH1-10GE on a redundant nearline K2 SAN.

Dell R610 NH1-10GE for online K2 SANThese cabling instructions apply to the following:

• Dell R610 PowerEdge Server NH1-10GE on an online K2 SAN.

Dell R610 NH1-10GE for basic nearline K2 SANThese cabling instructions apply to the following:

• Dell R610 PowerEdge Server NH1-10GE on a basic (non-redundant) nearline K2 SAN.

1 2

Gb 2Gb 1

Fibre Channel toRAID controller 1

Fibre Channel toRAID controller 0

To control porton GigE switch A

1 2

Gb 2Gb 1

Fibre Channel toRAID controller 1

Fibre Channel toRAID controller 0

To control porton GigE switch B

A

B

FTP: To 10 Gig port on GigE switch A

FTP: To 10 Gig port on GigE switch B

FTP: To 10 Gig port on GigE switch

Fibre Channelto RAID controller

To control porton GigE switch

To control porton GigE switch

FTP: To 10 Gig port on GigE switch

Fibre Channelto RAID controller

K2 Storage Cabling Guide 01 April 2010

Page 51: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Dell R610 NH1-10GE for redundant nearline K2 SAN

Dell R610 NH1-10GE for redundant nearline K2 SANThese cabling instructions apply to the following:

• Dell R610 PowerEdge Server NH1-10GE on a redundant nearline K2 SAN.

Fibre Channel toRAID controller 1

Fibre Channel toRAID controller 0

To control porton GigE switch A

Fibre Channel toRAID controller 1

Fibre Channel toRAID controller 0

To control porton GigE switch B

A

B

FTP: To 10 Gig port on GigE switch A

FTP: To 10 Gig port on GigE switch B

01 April 2010 K2 Storage Cabling Guide 51

Page 52: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

52

Chapter 2 Cable K2 devices

Cable K2 RAIDAs directed by the system diagram for your K2 storage, cable the K2 RAID devices using the instructions in this section.

• “K2 RAID for Level 2 basic K2 SAN” on page 53

• “K2 RAID for Level 2 redundant K2 SAN” on page 54

• “K2 RAID for basic K2 SAN” on page 55

• “K2 RAID for redundant K2 SAN” on page 56

• “K2 RAID for Level 10 basic K2 SAN” on page 57

• “K2 RAID for Level 10 redundant K2 SAN” on page 58

• “K2 RAID for Level 20 basic K2 SAN” on page 59

• “K2 RAID for Level 20 redundant K2 SAN” on page 60

• “K2 RAID for Level 30 basic K2 SAN” on page 61

• “K2 RAID for Level 30 redundant K2 SAN” on page 62

• “K2 RAID for Level 35 basic K2 SAN” on page 63

• “K2 RAID for Level 35 redundant K2 SAN” on page 64

• “K2 RAID for Nearline 10 basic K2 SAN” on page 65

• “K2 RAID for Nearline 10 redundant K2 SAN” on page 66

• “K2 RAID for K2 client direct-connect storage” on page 67

K2 Storage Cabling Guide 01 April 2010

Page 53: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2 RAID for Level 2 basic K2 SAN

K2 RAID for Level 2 basic K2 SANThese cabling instructions apply to the following:

• Level 2 (NEC 1300) K2 RAID on a Level 2 basic (non-redundant) K2 SAN.

1

ChassisAddress = 1

ID = “0”

4 3 2 1 ON

DiagnosticCable

Primary

Expansion

To K2 MediaServer

To control porton GigE switch

0 1

Address ID = 1

01 April 2010 K2 Storage Cabling Guide 53

Page 54: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

54

Chapter 2 Cable K2 devices

K2 RAID for Level 2 redundant K2 SANThese cabling instructions apply to the following:

• Level 2 (NEC 1300) K2 RAID on a Level 2 redundant K2 SAN.

1

ChassisAddress = 1

ID = “0”

4 3 2 1 ON

0 2

Address ID = 2

0 1

Address ID = 1

DiagnosticCable

DiagnosticCable

Primary

Expansion

To K2 MediaServer B

To K2 MediaServer A

To control port on GigE switch A

K2 Storage Cabling Guide 01 April 2010

Page 55: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2 RAID for basic K2 SAN

K2 RAID for basic K2 SANThese cabling instructions apply to the following:

• Level 3 (NEC 1400) K2 RAID on a Level 3 basic (non-redundant) K2 SAN.

Primary Chassis

Expansion Chassis 1

Expansion Chassis 2

Set address to 0

Set address to 1

Set address to 0

Set address to 1

DL1 DL0

To K2 MediaServer 2

To ExpansionChassis 3,with addressset to 1

To ExpansionChassis 4,with addressset to 2

To K2 MediaServer 1

To control porton GigE switch

The cable/address pattern, extended for additional Expansion Chassis, is as follows: Expansion Connect Set address Chassis # to... to... 1 DL1 0 2 DL0 1 3 DL1 1 4 DL0 2 5 DL1 2 6 DL0 3 7 DL1 3For more information, refer to the K2 Storage System Instruction Manual.

01 April 2010 K2 Storage Cabling Guide 55

Page 56: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

56

Chapter 2 Cable K2 devices

K2 RAID for redundant K2 SANThese cabling instructions apply to the following:

• Level 3 (NEC 1400) K2 RAID on a Level 3 redundant K2 SAN.

To K2 MediaServer 2B

DL1

Primary

Expansion 1

Expansion 2

Set address to 0 Set address to 0

Set address to 1 Set address to 1

DL1

To K2 MediaServer 1B

To K2 MediaServer 2A

To K2 MediaServer 1A

To control porton GigE switch A

To control porton GigE switch B

NOTE: Use this cable/address pattern for one or two expan-sion chassis only. For more expansion chassis you must use a different pattern, as specified in the K2 Storage System Instruction Manual.

K2 Storage Cabling Guide 01 April 2010

Page 57: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2 RAID for Level 10 basic K2 SAN

K2 RAID for Level 10 basic K2 SANThese cabling instructions apply to the following:

• Level 10 K2 RAID (Condor with CL1 controller) on a Level 10 basic (non-redundant) K2 SAN.

Continue this cable pattern for additional Expansion Chassis.

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Primary

Expansion 1

Expansion 2

To control porton GigE switch

DP0

ToExpansion

3

To K2 MediaServer

SAS cable connectors are keyed to DP IN/OUT ports.

SAS cables

01 April 2010 K2 Storage Cabling Guide 57

Page 58: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

58

Chapter 2 Cable K2 devices

K2 RAID for Level 10 redundant K2 SANThese cabling instructions apply to the following:

• Level 10 K2 RAID (Condor with CL1 controllers) on a Level 10 redundantK2 SAN.

Continue this cable pattern for additional Expansion Chassis.

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Primary

Expansion 1

Expansion 2

DP0

To K2 MediaServer A

To K2 MediaServer B

To control porton GigE switch A

To control porton GigE switch B

DP0

Controller 1 Controller 0

ToExpansion

3

ToExpansion

3

SAS cable connectors are keyedto DP IN/OUT ports.

SAS cables

K2 Storage Cabling Guide 01 April 2010

Page 59: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2 RAID for Level 20 basic K2 SAN

K2 RAID for Level 20 basic K2 SANThese cabling instructions apply to the following:

• Level 20 K2 RAID (Condor with CL1 controller) on a Level 20 basic (non-redundant) K2 SAN.

Continue this cable pattern for additional Expansion Chassis.

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Primary

Expansion 1

Expansion 2

To control porton GigE switch

DP0

ToExpansion

3

To K2 MediaServer A

To NH server(optional)

SAS cable connectors are keyed to DP IN/OUT ports.

SAS cables

01 April 2010 K2 Storage Cabling Guide 59

Page 60: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

60

Chapter 2 Cable K2 devices

K2 RAID for Level 20 redundant K2 SANThese cabling instructions apply to the following:

• Level 20 K2 RAID (Condor with CL1 controllers) on a Level 20 redundant K2 SAN.

Continue this cable pattern for additional Expansion Chassis.

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Primary

Expansion 1

Expansion 2

DP0

To K2 MediaServer A

To K2 MediaServer B

To NH server(optional)

To NH server(optional)

To control porton GigE switch A

To control porton GigE switch B

DP0

Controller 1 Controller 0

ToExpansion

3

ToExpansion

3

SAS cable connectors are keyedto DP IN/OUT ports.

SAS cables

K2 Storage Cabling Guide 01 April 2010

Page 61: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2 RAID for Level 30 basic K2 SAN

K2 RAID for Level 30 basic K2 SANThese cabling instructions apply to the following:

• Level 30 K2 RAID (Condor with CL2 controller) on a Level 30 basic (non-redundant) K2 SAN.

Continue this cable pattern for additional Expansion Chassis.

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Primary

Expansion 1

Expansion 2

DP0DP1

ToExpansion

3

ToExpansion

4

To control porton GigE switch

To K2 MediaServer A

To NH server(optional)

SAS cable connectors are keyed to DP IN/OUT ports.

SAS cables

01 April 2010 K2 Storage Cabling Guide 61

Page 62: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

62

Chapter 2 Cable K2 devices

K2 RAID for Level 30 redundant K2 SANThese cabling instructions apply to the following:

• Level 30 K2 RAID (Condor with CL2 controllers) on a Level 30 redundant K2 SAN.

Continue this cable pattern for additional Expansion Chassis.

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Primary

Expansion 1

Expansion 2

DP0DP1

ToExpansion

3

ToExpansion

4

DP0DP1

ToExpansion

3

ToExpansion

4

To K2 MediaServer A

To K2 MediaServer B

To control porton GigE switch A

To control porton GigE switch B

Controller 1 Controller 0

SAS cable connectors are keyedto DP IN/OUT ports.

SAS cables

To NH server(optional)

To NH server(optional)

K2 Storage Cabling Guide 01 April 2010

Page 63: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2 RAID for Level 35 basic K2 SAN

K2 RAID for Level 35 basic K2 SANThese cabling instructions apply to the following:

• Level 35 K2 RAID (Condor with CL2 controller with expansion FC ports) on a Level 35 basic (non-redundant) K2 SAN.

Continue this cable pattern for additional Expansion Chassis.

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Primary

Expansion 1

Expansion 2

DP0DP1

ToExpansion

3

ToExpansion

4

To control porton GigE switch

To K2 MediaServer 1

To NH server(optional)

To K2 MediaServer 2

SAS cable connectors are keyed to DP IN/OUT ports.

SAS cables

01 April 2010 K2 Storage Cabling Guide 63

Page 64: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

64

Chapter 2 Cable K2 devices

K2 RAID for Level 35 redundant K2 SANThese cabling instructions apply to the following:

• Level 35 K2 RAID (Condor with CL2 controllers with expansion FC ports) on a Level 35 redundant K2 SAN.

Continue this cable pattern for additional Expansion Chassis.

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Primary

Expansion 1

Expansion 2

DP0DP1

ToExpansion3

ToExpansion4

DP0DP1

Controller 0

ToExpansion3

ToExpansion4

To controlport on GigEswitch A

To K2MediaServer1A

To NHserver(optional)

To K2MediaServer2A

To controlport on GigEswitch B

To K2MediaServer1B

To NHserver(optional)

To K2MediaServer2B

Controller 1

SAS cable connectors are keyedto DP IN/OUT ports.

SAS cables

K2 Storage Cabling Guide 01 April 2010

Page 65: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2 RAID for Nearline 10 basic K2 SAN

K2 RAID for Nearline 10 basic K2 SANThese cabling instructions apply to the following:

• Lx0 K2 RAID (Condor with CL1 controller) on a Nearline 10 basic (non-redundant) K2 SAN.

Continue this cable pattern for additional Expansion Chassis.

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Primary

Expansion 1

Expansion 2

To control porton GigE switch

DP0

ToExpansion

3

To NH server

SAS cable connectors are keyed to DP IN/OUT ports.

SAS cables

01 April 2010 K2 Storage Cabling Guide 65

Page 66: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

66

Chapter 2 Cable K2 devices

K2 RAID for Nearline 10 redundant K2 SANThese cabling instructions apply to the following:

• Lx0 K2 RAID (Condor with CL1 controllers) on a Nearline 10 redundant K2 SAN.

Continue this cable pattern for additional Expansion Chassis.

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Primary

Expansion 1

Expansion 2

DP0

To NHserver A

To NHserver A

To NHserver B

To NHserver B

To control porton GigE switch A

To control porton GigE switch B

DP0

Controller 1 Controller 0

ToExpansion

3

ToExpansion

3

SAS cable connectors are keyedto DP IN/OUT ports.

SAS cables

K2 Storage Cabling Guide 01 April 2010

Page 67: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

K2 RAID for K2 client direct-connect storage

K2 RAID for K2 client direct-connect storageThese cabling instructions apply to the following:

• K2 RAID (Condor) providing direct-connect storage for a K2 Media Client or K2 Summit Production Client.

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

BBU IN MODEM

FLT/LNK

HPEFLT

A/LBACKUP

ACT/LNKLNK/ACT

FLT

HP5 4 3 2

RDY

LAN

BAT

MNT

ACSMC

DP1 DP0 HP1 0

Controller 1 Controller 0

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

DP0 DP0

To control porton GigE switch

To control porton GigE switch

To K2 clientFibre Channel port

To K2 clientFibre Channel port

RAID Primary

RAID Expansion 1

RAID Expansion 2

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

FLT/LNKFLT RDY

DP-OUTPS

FLT CLR DP-IN

RAID Expansion 3

Cable connectors are keyedto DP IN/OUT ports.

01 April 2010 K2 Storage Cabling Guide 67

Page 68: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

68

Chapter 2 Cable K2 devices

K2 Storage Cabling Guide 01 April 2010

Page 69: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Chapter 3

For more information

Refer to product documentation and if necessary access Grass Valley Support information to complete the installation of your K2 SAN.

• “K2 Release Notes” on page 69

• “K2 Documentation CD” on page 69

• “On-line Help Systems” on page 70

• “NetCentral documentation” on page 70

• “Grass Valley Web Site” on page 70

• “Using the Dell Server documentation” on page 70

• “” on page 71

K2 Release NotesThe K2 Release Notes contain the latest information about the software shipped on your system. The release notes include software upgrade instructions, software specifications and requirements, feature changes from the previous releases, and any known problems. Because release notes contain the latest information, they are printed out and included in the K2 product shipping box, rather than included in the Documentation CD-ROM. You should always check the Grass Valley Website to determine if there is an updated version of release notes available.

K2 Documentation CDExcept for the release notes, the full set of support documentation, including this manual, is available on the K2 Documentation CD that you receive with your K2 products. You can find the Documentation CD packaged in K2 product shipping boxes.

The Documentation CD-ROM includes the following:

• K2 SAN Installation and Service Manual (for version 7.x systems) or K2 Storage System Instruction Manual (for version 3.x systems) — Contains installation, configuration, and maintenance procedures for shared storage options.

• K2 SAN Cabling Guide — Contains diagrams for cabling the devices of the K2 SAN.

• RAID Instruction Manuals — There is an Instruction Manual for each type of RAID storage device that can be a part of a K2 SAN. These manuals contain procedures for configuring and servicing the device.

• K2 System Guide — Contains the product specifications and instructions for modifying system settings.

• Quick Start Guides — The Quick Start Guides for K2 Media Client or K2 Summit Production Client models provide step-by-step installation instructions for basic installation and operation.

01 April 2010 K2 Storage Cabling Guide 69

Page 70: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

70

Chapter 3 For more information

• User Manual — Provides instructions for configuring and operating the media channels of product.

• Service Manual — The Service Manual for the K2 Media Client or K2 Summit Production Client contains information on servicing and maintenance.

• Fibre Channel Switch Installation Manual — Contains information on configuring and servicing the Fibre Channel switch.

• SiteConfig User Manual — Contains information on using SiteConfig, Grass Valley’s system management tool, for network configuration and software deployment.

On-line Help SystemsK2 AppCenter Help — In the AppCenter user interface menu bar select Help, then choose AppCenter Help Topics from the drop-down menu.

SiteConfig Help — In the SiteConfig user interface menu bar select Help, then choose SiteConfig Help Topics from the drop-down menu.

NetCentral Help — From the NetCentral interface select Help | NetCentral Help Topics.

NetCentral documentationThe NetCentral product has its own documentation set, described as follows:

• NetCentral Quick Start Guide — Provides an overview of the installation process to quickly set up and run NetCentral.

• NetCentral Installation Guide — Identifies requirements and procedures to correctly set up servers and devices, as well as provides detailed instructions to install and configure NetCentral software.

• NetCentral User Guide — Describes how to use the NetCentral Manager to monitor devices.

• NetCentral Help — From the NetCentral interface access on-line help. Select Help | NetCentral Help Topics.

Grass Valley Web SiteThis public Web site contains all the latest manuals and documentation, and additional support information. Use the following URL.

http://www.grassvalley.com.

Using the Dell Server documentationThis manual contains all of the information you need to install the K2 SAN, however, a full set of Dell server documentation has been provided on the Dell Product Documentation CD-ROM. The Dell server documentation applies to the K2 Media Server. Refer to the documents on this CD-ROM only as required by procedures in this manual.

K2 Storage Cabling Guide 01 April 2010

Page 71: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Grass Valley Product Support

Information referenced on the Dell Product Documentation CD-ROM includes, but is not limited to:

• Unpacking and rack-mounting the K2 Media Server

• Important safety and regulatory information

• K2 Media Server Status indicators, messages, and error codes

• Troubleshooting help for the K2 Media Server hardware.

CAUTION: Do not use the Dell Quick Installation Guide provided with the Dell CD-ROM package. This guide includes instructions for using the OpenManage software CD-ROM to install an operating system. The K2 Media Server comes fully configured and is ready for installation. To begin installation, refer to one of the installation chapters in this manual.

Grass Valley Product SupportTo get technical assistance, check on the status of a question, or to report a new issues, contact Grass Valley Product Support via e-mail, the Web, or by phone or fax.

Web Technical SupportTo access support information on the Web, visit the product support Web page on the Grass Valley Web site. You can download software or find solutions to problems.

World Wide Web:http://www.grassvalley.com/support/

Technical Support E-mail Address:[email protected]

!

01 April 2010 K2 Storage Cabling Guide 71

Page 72: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

72

Chapter 3 For more information

Telephone SupportUse the following information to contact Product Support by phone.

International Support Centers

Our international support centers are available 24 hours a day, 7 days a week.

Authorized Local Support Representative

A local support representative may be available in your country. To locate a support center during normal local business hours, refer to the following list. This list is regularly updated on the website for Grass Valley Product Support

(http://www.grassvalley.com/support/contact/phone/)

After–hours local phone support is also available for warranty and contract customers.

Support Center Toll free In country

France +800 80 80 20 20 +33 1 48 25 20 20

United States +1 800 547 8949 +1 530 478 4148

Region County Telephone

Asia China +86 10 5883 7575

Hong Kong, Taiwan, Korea, Macau

+852 2531 3058

Japan +81 3 6848 5561

Southeast Asia - Malaysia +603 7492 3303

Southeast Asia - Singapore +65 6379 1313

India +91 22 676 10300

Pacific Australia 1 300 721 495

New Zealand 0800 846 676

For callers outside Australia or New Zealand

+61 3 8540 3650

Central America, South America All +55 11 5509 3440

North America North America, Mexico, Caribbean

+1 800 547 8949; +1 530 478 4148

K2 Storage Cabling Guide 01 April 2010

Page 73: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

Waste Electrical and Electronic Equipment Directive

Waste Electrical and Electronic Equipment Directive

Europe UK, Ireland, Israel +44 118 923 0499

Benelux – Netherlands +31 (0) 35 62 38 421

Benelux – Belgium +32 (0) 2 334 90 30

France +80 0 80 80 20 20; +33 1 48 25 20 20

Germany, Austria, Eastern Europe

+49 6150 104 444

Belarus, Russia, Tadzhikistan, Ukraine, Uzbekistan

+7 095 258 09 20; +33 (0) 2 334 90 30

Nordics (Norway, Sweden, Finland, Denmark, Iceland)

+45 40 47 22 37; +32 2 333 00 02

Southern Europe – Italy Rome: +39 06 87 20 35 28 ; +39 06 8720 35 42. Milan: +39 02 48 41 46 58

Southern Europe – Spain +34 91 512 03 50

Switzerland +41 56 299 36 32

Middle East, Near East, Africa Middle East +971 4 299 64 40

Near East and Africa +800 80 80 20 20; +33 1 48 25 20 20

Region County Telephone

01 April 2010 K2 Storage Cabling Guide 73

Page 74: K2 Storage Cabling Guide - Grass Valley...8 K2 Storage Cabling Guide 01 April 2010 Chapter 1 Start with the K2 storage system diagram Level 2 Basic K2 SAN This manual documents the

74

Chapter 3 For more information

K2 Storage Cabling Guide 01 April 2010