K2 Storage Area NetworkNearline 10 Cabling Guide071-8599-01 March 13, 2009
1. Unpack
Mount devices in your racks. A suggested elevation is shown.
To support RAID bezels, attach brackets over chassis protrusions as shown.
2. Rack
3a. Cable as shown for non-redundant (NL10) system. Follow step 3b on reverse side for redundant system.
! K2 SAS STORAGE
! K2 SAS STORAGE
Read the K2 SAN Installation and Service Manual and other manuals on the Documentation CD for complete instructions.
- User Guide- System Guide- Service Manual- SAN Manual- RAID Instruction Manuals
K2Documentation Xxx 200x Software version XX
System Requirements:Microsoft Windows and Internet Explorer 5.5x or Netscape 4.7x or later.
If this disc does not auto-start, open the
home.htm file on the disc.
.
*
Ports are for control connections as well as FTP connections from Grass Valley and 3rd party systems.
Control
RAID Chassis(SATA drives)
RAID Expansion Chassis(SATA drives)
NH K2 MediaServer
Gigabit EthernetSwitch
Fibre Channelconnection
ControlF
TP
Control point PC
! K2 SATA STORAGE
! K2 SATA STORAGE
! K2 SATA STORAGE
! K2 SATA STORAGE
K2 MEDIA SERVER
Control
FTP to/from online system
10 Gig FTP connection to rear of switch for NH1-10GE server
FLT/LNKFLT RDY
DP-OUTPS
FLT CLR DP-IN
FLT/LNKFLT RDY
DP-OUTPS
FLT CLR DP-IN
FLT/LNKFLT RDY
DP-OUTPS
FLT CLR DP-IN
FLT/LNKFLT RDY
DP-OUTPS
FLT CLR DP-IN
BBU IN MODEM
FLT/LNK
HPEFLT
A/LBACKUP
ACT/LNKLNK/ACT
FLT
HP5 4 3 2
RDY
LAN
BAT
MNT
ACSMC
DP1 DP0 HP1 0
BBU IN MODEM
FLT/LNK
HPEFLT
A/LBACKUP
ACT/LNKLNK/ACT
FLT
HP5 4 3 2
RDY
LAN
BAT
MNT
ACSMC
DP1 DP0 HP1 0
Primary
Expansion 1
Expansion 2
To control porton GigE switch
DP0
ToExpansion
3
To NH server
SAS cable connectors are keyed to DP IN/OUT ports.
SAS cables
1 2
Gb 2Gb 1
To control porton GigE switch
FTP: To 10 Gig port on GigE switch
Fibre Channelto RAID controller
1
Gb 2Gb 1
Fibre Channelto RAID controller
To control porton GigE switch
FTP: To control porton GigE switch
or
NH110GE
NH1
Continue this cable pattern for additional Expansion Chassis
NHK2 Media Server
Chassis protrusions
Frontrailbracket
RAID PrimaryChassis
RAID Expansion Chassis (optional)
K2 Media Servers
Gigabit Ethernet Switches
K2 MEDIA SERVER
K2 MEDIA SERVER
! K2 SAS STORAGE
! K2 SAS STORAGE
! K2 SAS STORAGE
! K2 SAS STORAGE
K2 MEDIA SERVER
Open boxes and find documentation in product packaging.
Documentation CD*Cabling GuideRelease Notes
Manufacturer’s documentation
None
None
Documentation packed with Gigabit Ethernet Switch:
Documentation packed with RAID Primary Chassis:
Documentation packed with RAID Expansion Chassis:
Documentation packed with K2 Media Server:
3b. Cable as shown for redundant (NL10R) system. Follow step 3a on reverse side for non-redundant system.
Ports are for control connections as well as FTP connections from Grass Valley and 3rd party systems.
ISLs
Control
Control
RAID Chassis(SAS drives)
RAID Expansion Chassis(SATA drives)
NH K2 MediaServers
Gigabit EthernetSwitches
Fibre Channelconnections
ControlF
TP
ControlF
TP
Control point PC
! K2 SATA STORAGE
! K2 SATA STORAGE
! K2 SATA STORAGE
! K2 SATA STORAGE
K2 MEDIA SERVERK2 MEDIA SERVER
Control
FTP to/from online system
ISLsA
A
B
B
B
A
Inter-Switch Links (ISLs)10 Gig FTP connections to rear of switch for NH1-10GE servers
1
Gb 2Gb 1
Fibre Channel toRAID controller 1
Fibre Channel toRAID controller 0
To control porton GigE switch A
1
Gb 2Gb 1
Fibre Channel toRAID controller 1
Fibre Channel toRAID controller 0
To control porton GigE switch B
A
B
FTP: To 10 Gig port on GigE switch A
FTP: To 10 Gig port on GigE switch B
1
Gb 2Gb 1
Fibre Channel toRAID controller 1
Fibre Channel toRAID controller 0
To control porton GigE switch A
FTP: To control porton GigE switch A
1
Gb 2Gb 1
Fibre Channel toRAID controller 1
Fibre Channel toRAID controller 0
To control porton GigE switch B
FTP: To control porton GigE switch B
A
B
or
NH110GE
NH1
FLT/LNKFLT RDY
DP-OUTPS
FLT CLR DP-IN
FLT/LNKFLT RDY
DP-OUTPS
FLT CLR DP-IN
FLT/LNKFLT RDY
DP-OUTPS
FLT CLR DP-IN
FLT/LNKFLT RDY
DP-OUTPS
FLT CLR DP-IN
BBU IN MODEM
FLT/LNK
HPEFLT
A/LBACKUP
ACT/LNKLNK/ACT
FLT
HP5 4 3 2
RDY
LAN
BAT
MNT
ACSMC
DP1 DP0 HP1 0
BBU IN MODEM
FLT/LNK
HPEFLT
A/LBACKUP
ACT/LNKLNK/ACT
FLT
HP5 4 3 2
RDY
LAN
BAT
MNT
ACSMC
DP1 DP0 HP1 0
Primary
Expansion 1
Expansion 2
DP0
To NHserver A
To NHserver A
To NHserver B
To NHserver B
To control porton GigE switch A
To control porton GigE switch B
DP0
Controller 1 Controller 0
ToExpansion
3
ToExpansion
3
SAS cable connectors are keyedto DP IN/OUT ports.
SAS cables
Redundant (A/B) NH K2 Media Servers
Continue this cable pattern for additional Expansion Chassis
NOTE: Redundant NH servers must be of the same type, either both NH1-10GE or both NH1.
Copyright © Thomson, Inc. All rights reserved.