3
Just 1 leg through CT Resistor already installed Power Kriwan - 1 phase monitoring / resistor installed / Bi-metal 5 pin terminal Plate (Klixon) overloads

Just 1 leg through CT Power Resistor already installed

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Just 1 leg through CT

Resistor already installed

Power

Kriwan -

1 phase monitoring / resistor installed / Bi-metal 5 pin terminal Plate (Klixon) overloads

The MCC values below are provided for reference only. Before programming, verify MCC values with compressor specificaitons.

Compressor MCC Model Number (Amps) 06C *016D *** 27.0 06C * 016G * * * 13.5 06C * 016J * * * 10.8 06C * 017D * * * 27.0 06C * 017G * * • 13.5 06C * 017 J * * * 10.8 06C * 018D * * * 27.0 06C * 018G * * * 13.5

06C * 018J * * * 10.8 06C * 124D * * * 33.0 06C * 124G * * * 16.5 06C * 124J * * * 13.2 06C * 125D * * * 44.0 06C * 125G*** 22.0 06C * 125J * * * 17.6 06C * 228D * * * 41.6 06C * 228G * * * 20.9 06C * 228J * * * 16.7 06C * 337D * * * 46.6 06C * 337G * * * 23.3 06C*337J*** 18.8 06C * 3370 * * * 37.8 06D * 013 * * A 13 * * 10.5 06D *013 **A31 ** 7.0 06D * 013 * * A32 * * 17.4 06D * 013 * * A36 * * 8.7 06D * 1 09 * * A 13 * * 9.5 06D * 1 09 * * A31 * * 4.4 06D * 1 09 * * A32 * * 12.1 06D * 1 09 * * A36 * * 5,5 06D * 1 09 * * A39 * * 5.5 06D * 228 * * A 13 * * 33.6

ti 06D * 228 * * A31 * * 22.2 06D * 228 * * A32 * * 55.5 06D * 228 * * A36 * * 27.8

Compressor Model Number 06D * 237 * * A06 * * 06D * 237 * * A 12 * * 06D *313** A13 ** 06D*313**A31 ** 06D * 313 * * A32 * * 06D * 313 * * A34 * * 06D * 313 * * A36 * * 06D * 316 * * A13 * * 06D * 316 * * A31 * * 06D * 316 * * A32 * * 06D * 316 * * A34 * * 06D * 316 * * A36 * * 06D * 328 * * A01 * * 06D * 328 * * A05 * * 06D * 328 * * A06 * * 06D * 328 * * A08 * * 06D * 328 * * Ai 2 * * 06D * 328 • * A 13 * * 060 * 328 * * A31 * * 06D * 328 * * A32 * * 06D * 328 * * A34 * * 06D * 328 * * A36 * * 06D * 337 * * A01 * * 06D * 337 * * A05 * * 06D * 337 * * A06 * * 06D * 337 * * A08 * * 06D*337 **A12** 06D *337 **A13* * 060 * 337 * * A31 * * 06D * 337 * * A32 * * 060 * 337 * * A34 * * 06D * 337 * * A36 * * 06D * 537 * * A01 * * 06D * 537 * * A05 * * 06D * 537 * * A06 * *

MCC (Amps)

27.8 69.0 16.4 10.8 27.0 27.4 13.5 16.4 10.8 27.0 27.4 13.5 25.0 69.4 31.0 56.4 69.0 42.0 25.0 62.0 50.5 31.0 25.0 69.4 31.0 56.4 69.0 37.8 25.0 62.0 58.2 31.0 32.0 80.0 40.0

Compressor Model Number 06D * 537 * * A08 * * 06D * 537 * * A 12 * * 06D * 537 * * A 13 * * 06D * 537 * * A31 * * 06D * 537 * * A32 * * 06D * 537 * * A36 * * 060*541 **A01 ** 06D * 541 * * A06 * * 06D * 541 * * A08 * * 06D * 541 * * A09 * * 06D * 541 * * A 12 * * 06D * 541 * * A 13 * * 060 *-541 * * A31 * * 06D * 541 * * A32 * * 06D * 541 * * A36 * * 06D*718 **A13** 06D * 718 * * A31 * * 06D * 718 * * A32 * * 06D * 718 * * A36 * * 06D * 724 * * A01 * * 06D * 724 * * A06 * * 06D * 724 * * A12 * * 06D * 724 * * A13 * * 06D * 724 * * A31 * * 06D * 724 * * A32 * * 06D * 724 * * A36 * * 06D * 725 * * A06 * * 06D * 725 * * A 12 * * 06D * 725 * * A 13 * * 06D * 725 * * A31 * * 06D * 725 * * A32 * * 06D * 725 * * A36 * * 06D * 808 **A 13 * * 06D * 808 * * A31 * * 06D * 808 * * A32 * *

MCC (Amps)

75.0 89.0 54.2 32.0 89.0 40.0 32.0 40.0 75.0 40.0 89.0 54.2 32.0 89.0 40.0 16.4 10.8 27.0 13.5 19.7 22.0 48.8 26.6 17.6 44.0 22.0 22.0 48.8 26.6 17.6 44.0 22.0 10.5 7.0

17.4

Compressor MCC Model Number (Amps) 06D * 808 * * A34 * * 17.8 06D * 808 * * A36 * * 8.7 06D *816**A13** 26.6 06D*816 **A31 ** 17.6 06D.* 816 * * A32 * * 44.0 06D * 816 * * A34 * * 40.0 06D*816**A36** 22.0 06D * 818 * * A01 * * 19.7 06D * 818 * * A04 * * 54.6 06D * 818 * * A06 * * 24.6 06D * 818 * * A 12 * * 48.8 06D * 818 * * A13 * * 26 .. 6 06D *-818 * * A31 * * 17.6 06D * 818 * * A32 * * 44.0 06D * 818 * * A34 * * 40.0 06D * 818 * * A36 * * 22.0 050·• 820 • • A13 • • 2.6.6 06D * 820 * * A31 * * 17.6 06D * 820 * * A32 * * 44.0 06D * 820 * * A36 * * 22.0 06D * 824 * * A01 * * 24.9 06D * 824 * * A06 * * 27.8 06D *824**A12** 69.0 06D * 824 * * A 13 * * 33.6 06D * 824 * * A31 * * 22.2 06D * 824 * * A32 * * 55.5 06D * 824 * * A34 * * 50.5 06D * 824 * * A36 * * 27.8 06D * 825 * * A01 * * · 22.206D * 825 * * f\06 * * 27.8 06D*825**A12** 69.0 06D*825 **A13** 33.6 06D * 825 * * A31 * * 22.2 06D * 825 * * A32 * * 55.5 06D * 825 * * A34 * * 50.5 06D * 825 * * A36 * * 27.8

Open the INTspector App and select the USB Gateway button and wait for the connection to beestablished as shown by the next screen in step 3. (this may take approx. 20 seconds)

Once the connection to the INT 69 i 2 Diagnose is established, the following screen appearsautomatically. It may take a few additional seconds for the Change Parameters button toautomatically appear.

S T - example shown

Set Amps from Table - example shown

** Note: If you tap the buttons to the left & button turns green, this locks out compressor if safety trips

Make sure Disabled

12

** Trip delay means time that CT or module recognizes a problem to the time it trips compressor ** Reset delay is time to restart

0