80
SKIDMORE, OWINGS & MERRILL LLP

JUAN CARRION, PhD PE

Embed Size (px)

Citation preview

Page 1: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Page 2: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

SUPEREDIFICIOS: La nueva generación

JUAN CARRION, PhD PE

Skidmore, Owings & Merrill LLP, SOMChicago, Estados Unidos

SKIDMORE, OWINGS & MERRILL LLP

Page 3: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Trump Tower – Chicago

Willis Tower – Chicago

Pearl River Tower -

GuangzhouNanjing Greenland –

Nanjing

Burj Khalifa -

Dubai

Jin Mao Tower -

Shanghai

John Hancock Center -

Chicago

SOM: RASCACIELOS

Page 4: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

SOM: ESTRUCTURAS ESPECIALES

Pritzker Pavilion -

Chicago Guggenheim Museum - Bilbao

Gerry Sculpture -

Barcelona

Raspberry Island - Schubert Club Band Shell –

St. Paul

General Motors Renaissance Center - Detroit

Page 5: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

SOM: SITIOS COMPLEJOS

Memorial Sloan-

Kettering Research

Center – New York

201 Bishopsgate and The

Broadgate Tower - London

Ninth Avenue – New

YorkNinth Avenue – Site

201 Bishopsgate and The

Broadgate Tower - Site

Memorial Sloan-

Kettering Research

Center – Site

Page 6: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

SUPER EDIFICIOS

CTBUH define como Super altos “supertall” los edificios sobre los 300 meters

(984 feet) de altura y Mega altos “megatall” a los edificos sobre 600 meters

(1,968 feet) de altura.

Page 7: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

El edificio más alto del

mundo

1909 vs 2016

Page 8: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Existen muchas propuestas para rascacielos, sin embargo, pocas se llegan a realizar

Page 9: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Demasiado complicados

Muchos edificios altos y superaltos son concebidos sin el adecuado rigor funcional y estructural y son excesivamente complejos y prohibitivos.

Muy difíciles de construir

Los retos asociados con la construcción de edificios altos y superaltos requieren especial consideración. Proyectos que no son concebidos con

métodos prácticos de construcción generalmente no llegan a ser construidos.

Demasiado lentos

Sistemas excesivamente complejos resultan en retrasos en la construcción. La construcción de edificios altos y superaltos requiere diseños que

puedan ser construidos de forma rápida y eficiente.

Uso ineficiente de los materiales estructurales

Sistemas estructurales que no responden a las fuerzas principales que gobiernan el diseño de edificios altos y superaltos resultan en sistemas

ineficientes, costosos e inapropiados. Soluciones estructurales mediante “fuerza bruta” resultan en desperdicio de espacios, materiales,

tiempo y dinero.

RAZONES

Page 10: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

•Limitaciones en escalamiento

•Limitaciones en el espacio interior útil

•Limitaciones en la distancia al suelo

•Limitaciones en la capacidad de mercado

LIMITACIONES EN EL TAMAÑO DE EDIFICIOS SUPERALTOS

Page 11: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Los edificios super altos no son prácticos

ni eficientes si son versiones escaladas de

edificios más pequeños.

Los edificios super altos requieren nuevas

topologías y sistemas

LIMITACIONES EN ESCALAMIENTO

Page 12: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

LIMITACIONES EN EL ESPACIO INTERIOR UTIL

Espacios interiores profundos y lejos de las ventanas perimetrales son de limitado valor práctico.

Las versiones escaladas de otros edificios resultan en proporciones grandes de espacio interior inusable.

Page 13: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

600m

800m

1,000m

1,600m (1 mile)

Occupied to 450 – 500m

Occupied to 600m – 650m

Occupied to 600m – 750m

Partially Occupied to 800-1000m

El transporte vertical por elevadores y los servicios a las zonas ocupadas se

complican con la altura.

Tamaños mínimos de la planta limitan la ubicación de los pisos ocupados más

altos.

Los problemas de servicios son reducidos mediante el uso de formas con

sección variable (más angostas en la parte alta), las cuales reducen el nivel de

ocupación en los pisos más altos.

LIMITACIONES EN LA DISTANCIA AL SUELO

Page 14: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

600m

800m

1,000m

1,600m (1 mile)LIMITACIONES EN LA CAPACIDAD DE MERCADO

A medida que los edificios super altos alcanzan una cierta altura, el área

contenida puede exeder las limitaciones del mercado.

Las zonas de ocupación también puede llegar a exceder el límite de lo que se

puede servir a través del nucleo central.

Alcanzar alturas extremas puede requerir en ciertos casos que los edificios

sean diseñados para estar parcilamente ocupados.

GFA: 180,000m3 –220,000m3

GFA: 280,000m3 –340,000m3

GFA: 300,000m3 –360,000m3

GFA: 350,000m3 –1,000,000m3

(partially occupied)

Page 15: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Los edificios que llegan a ser construidos son:

RacionalesEl diseño racional de ingeniería informa a la forma arquitectónica desde el comienzo del proceso de diseño. La forma del edificio y el sistema estructural reflejan los principios físicos que gobiernan el comportamiento de edificios altos

ApropiadosLa relación entre arquitectura y estructura está adaptada a las demandas especiales de construir super alto. El sistema estructural no es ni secundario o inferior a la forma del edificio, ni dominante o desagradable a la vista.

RápidosLas soluciones estructurales y arquitectónicas toman en cuenta la constructibilidad, velocidad de construcción y el costo. Ingenieros de SOM preveen problemas técnicos y de construcción pronto, por lo tanto eliminando iteraciones de rediseño y problemas constructivos.

EficientesLos diseños estructurales de SOM son optimizados para las demandas únicas de edificios altos, maximizando la resistencia y rigidez y minimizando las cantidades de la estructura. Métodos de análisis con tecnología de punta aseguran que cada parte de la estructura es tan eficiente como sea posible. Por lo tanto, costos son reducidos.

ElegantesIngeniería de SOM considera que soluciones de ingeniería que son a la vez racionales, apropiadas, prácticas y eficientes son naturalmente elegantes. Un diseño elegante revela su lógica interna y será atractivo en su propia forma.

Ajustan a las condiciones del sitioLos edificios se ajustan de forma inteligente y apropiada a las condiciones particulares del sitio.

SOM INGENIERÍA DE RASCACIELOS

Page 16: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

RacionalEl diseño de ingeniería toma en cuanta y refleja los principios físicos que gobiernan el comportamiento de edificios altos

La forma del edificio sigue los diagramas de fuerzas de

gravedad y momentos desestabilizantes de viento

Diagrama de momentos desestabilizantes de viento

Diagrama de cargasverticales

Forma potencial de edificio alto

Page 17: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Forma ApropiadaFormas apropiadas de edificios altos son conseguidas seleccionando la forma que maximiza la rigidez y

variando la forma, estrechez, y tratamientos superficiales para de esta manera reducir los efectos del viento

que produzcan vibraciones.

Page 18: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Rápido

Las soluciones estructurales y arquitectónicas toman en cuenta la constructibilidad, velocidad de construcción

y el costo. Ingenieros de SOM preveen problemas técnicos y de construcción pronto, por lo tanto eliminando

iteraciones de rediseño y problemas constructivos.

Sistema de encofrado trepante permiteconstrucción rápida y de costo eficiente

Page 19: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Burj Khalifa – 160+ Stories

Page 20: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Eficiencia de la forma del sistema estructural

Sistemas para edificios altos160+ STORIES

Eficiente

Page 21: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

EleganteIngenieros en SOM consideran que soluciones de ingeniería que son a la vez racionales, apropiadas, prácticas y eficientes, son

naturalmente elegantes. Un diseño elegante revela su lógica interna y será atractivo en su propia forma.

Diseños por SOM de edificios super altos:

Page 22: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Se ajustan a las condiciones del sitioLas diferentes condiciones de sitio requieren diferentes tipos de soluciones

tanto arquitectónicas como estructurales

Page 23: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Edificios diseñados por SOM

Page 24: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Jeddah Tower1000 m

(Construccion)

Burj Khalifa828 m

Empire State Bldg434 m

Eiffel Tower324 m

… ?

CUAL ES EL SIGUIENTE?

Page 25: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

35 HUDSON YARDS MANHATTAN WEST

HUDSON YARDS AND MANHATTAN WEST

New York City, New York

Page 26: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

HUDSON YARDS AND MANHATTAN WESTNew York City, New York

Page 27: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

MWHY

Page 28: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Page 29: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

BROADGATE EXCHANGE HOUSE – TERMINADO EN 1990

EXPERIENCIA SOBRE RIELES

Page 30: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

201 BISHOPSGATE & BROADGATE TOWER – TERMINADO EN 2009

EXPERIENCIA SOBRE RIELES

Page 31: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

PROYECTO HUDSON YARDS

Page 32: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

35 HUDSON YARDS

Altura de la torre es de 1010 pies (308 metros) sobre la Planta Baja (Lobby).

La torre tiene 72 pisos y está destinada para uso múltiple.

Está construida enteramente sobre las rieles de tren.

Page 33: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

EQUINOX

OFFICE

EQUINOX HOTEL

RESIDENTIAL

1010’-0”

RETAIL

PROGRAMA ARQUITECTONICO

Page 34: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

EQUINOX

OFFICE

EQUINOX HOTEL

RESIDENTIAL

1010’-0”

RETAIL

HEALTH

CLUB/RETAIL

OFFICE

HOTEL

RESIDENTI

AL

Concrete

Belt Walls

Concrete Buttress

Wall

Concrete

Column/

Concrete Flat

Plate

Concrete Core

Wall

Concrete

Column/

Concrete Flat

Plate

Concrete Belt

Walls

Concrete

Column/

Concrete Flat

Plate

PROGRAMA ARQUITECTONICO SISTEMA ESTRUCTURAL

Page 35: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

SISTEMA DE MUROS DE CONCRETO REFORZADO(NUCLEO CENTRAL + MUROS CINTURON + CONTRAFUERTES)

COLUMNASDE CONCRETO REFORZADO

LOSAS DE CONCRETO REFORZADO SISTEM ESTRUCTURALCOMPLETO

COMPONENTES DEL SISTEMA ESTRUCTURAL

Page 36: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

MATERIALES

ConcretoMuros estructurales: f’c =10,000 psi - 14,000 psiColumnas: f’c =10,000 psi - 14,000 psiLosas y vigas: f’c = 7,200 psi – 10,000 psiLosas sobre placa de acero: f’c = 5,000 psi

Acero de RefuerzoASTM A615, ASTM A706 (Weldable Rebar)BARRAS #3‐#11 Gr 60BARRAS #14‐#20 Gr 80

Acero EstructuralPerfiles laminados ASTM A992 Gr. 50Placas ASTM A572 Gr. 50Elementos embedidos en concreto Gr. 65

SISTEMA ESTRUCTURAL

Page 37: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Tower base supported by platform structure

PLATAFORMAESTRUCTURAL

NIVEL DE LAS RIELES

NIVEL DE PLANTA BAJA

BASE DE LA ESTRUCTURA

Page 38: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

PLATAFORMAESTRUCTURAL

Page 39: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

SISTEMA DE MUROS DE LA TORRE (NUCLEO CENTRAL Y CONTRAFUERTES)

Page 40: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

COLUMNA CABEZA DE MARTILLO (Hammerhead Column)

COLUMNAS DE LA TORRE

Page 41: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

PLATAFORMAESTRUCTURAL

PILAS(CAISSONS)

Page 42: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

MUROS DE NUCLEO CENTRAL

(CORE WALLS)

COLUMNA CABEZA DE MARTILLO(HAMMERHEAD COLUMN)

COLUMNA CABEZA DE MARTILLO (HAMMERHEAD COLUMN)

ACERO ESTRUCTURAL EMBEBIDO(EMBEDDED STEEL CORE)

Page 43: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Mod0 1: X-Y Traslacion Modo 2: Y-X Traslacion Mode 3: Torsion

MODOS DE VIBRACION

Page 44: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

TUNEL DE VIENTO

Page 45: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

AMORTIGUADOR DE MASA SINTONIZADO (TDM)

Page 46: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

CONSTRUCCION – ELEMENTOS DE ACERO ESTRUCTURAL A SER EMBEBIDOS EN CONCRETO

Page 47: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Page 48: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

MANHATTAN WEST: NORTH TOWER

Cliente:

Brookfield Office Properties

Fase:

Construcción (Fecha de terminación 2017)

Altura

1034 pies (315 metros)

Numero de Pisos

72 Pisos

Area

2,000,000 ft2 (186,000 m2)

Uso

Comercial - Oficinas

Page 49: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

PROYECTO MANHATTAN WEST

Page 50: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

UBICACION

Page 51: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

UBICACION

NE TOWER

Page 52: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

PUENTE PLATAFORMA

Page 53: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

PUENTE PLATAFORMA

Page 54: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

SITIO DE LA TORRE NORTE

Page 55: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

RESTRICCIONES DEL SITIO

Page 56: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

RESTRICCIONES DEL SITIO

Page 57: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

REGULAR

ZONE

CRITICAL

ZONE

TRACKS BELOW BOX GIRDERS

TRACK BOX GIRDERS

RESTRICCIONES DEL SITIO - FLUJO DE FUERZAS

Page 58: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

RESTRICCIONES DEL SITIO - FLUJO DE FUERZAS

Page 59: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

LOBBY LIBRE DE COLUMNAS

Page 60: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Page 61: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Page 62: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

NUCLEO CENTRAL DE CONCRETOREFORZADO

SISTEMA DE ACERO ESTRUCTURAL PERIMETRAL

SISTEMA DE PISO DE ACEROESTRUCTURAL Y PLACA

COLABORANTE

SISTEM ESTRUCTURAL COMPLETO

SISTEMA ESTRUCTURAL

Page 63: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

MATERIALES

ConcretoCimentaciones f`c = 8,000 psiMuros estructurales: f’c =6,000 psi - 10,000 psiLosas y vigas: f’c = 5,000 psiLosas sobre placa de acero: f’c = 4,000 psi

Acero de RefuerzoASTM A615, ASTM A706 (Weldable Rebar)BARRAS #3‐#8 Gr 60BARRAS #9‐#11 Gr 80

Acero EstructuralPerfiles laminados ASTM A992 Gr. 50Placas para perfiles armados ASTM A572 Gr. 50W14 Columnas ASTM A913 Gr. 70W12, W24, W30, W36 Columnas ASTM A992 Gr. 50Placas para Conexiones ASTM A572 Gr. 50

Anclajes (Tie-Downs)Threaded Bars (Multiple corrosion protection) ASTM A722 Fu=150ksi

SISTEMA ESTRUCTURAL

Page 64: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

PLANTA TIPICA

Page 65: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

DISEÑO ESTRUCTURAL DE “KICKERS”

Page 66: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

DISEÑO Y DETALLAMIENTO DE “KICKERS”

Page 67: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

ANALISIS MEDIANTE ELEMENTOS FINITOS

Page 68: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

ANALISIS MEDIANTE ELEMENTOS FINITOS – ZONA CRITICA Y CIMENTACIONES

MODELO 3D FUERZAS EN LOS ANCLAJES

PRESIONES EN LA ROCA

Page 69: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

CONSTRUCCION - SITIO

Page 70: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

CONSTRUCCION - SITIO

Page 71: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

CONSTRUCCION - CIMENTACIONES

Page 72: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

CONSTRUCCION – ACERO A SER EMBEBIDO EN NUCLEO DE CONCRETO

Page 73: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

CONSTRUCCION – “KICKERS”

Page 74: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Page 75: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Page 76: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Page 77: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Page 78: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

Page 79: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP

PROYECTO MANHATTAN WEST

Page 80: JUAN CARRION, PhD PE

SKIDMORE, OWINGS & MERRILL LLP