DESCRIPTION
China made busway with ASTA
Citation preview
Your Reliable Busway Solution Experts
LB BUSWAY SYSTEM CATALOGUE
Su
bje
ct to
ch
an
ge w
ith
ou
t p
rio
r n
oti
ce
Head Office:
No.9 Xianjiang Rd, GETDD, Guangzhou,
Guangdong, China,
TEL: +86 20 3295 0008; +86 20 3295 0009
FAX: +86 20 3295 0886
WEBSITE: http://www.joya-electric.com
511356
North China Office:
Room 2209, 22/F, Silver Building, Xin Yuan
F i n a n c e P l a z a , J i n g 3 r d R d N o r t h ,
Zhengzhou, Hunan, China, 450000
TEL: +86 371 8661 7664
FAX: +86 371 8661 7664
Room3102, 31/F, 1 Unit, 17th Building, Taihe
Xindu, Henan Rd, Binhai New District,
Tianjin, China, 300425
TEL:+86 138 219 642 26
Your Reliable Busway Solution Experts
Overseas Office:
A-1-2, Kompleks Industri Puchong. No.1,
Ja lan TPP 1 /6 , Taman Per indus t r ian
Puchong, 47100 Puchong, Selangor D.E.,
Malaysia
TEL: +6 03-8068 6862
FAX: +6 03-8068 6525
Southwest China Office:
Room1-301, 3/F, 5th Building, International
Garden, No.23 Yong Feng Rd, Gaoxin
District, Chengdu, Sichuan,China, 610093
TEL: +86 28 8514 3269
FAX: +86 28 8514 3269
TEL: +86 771 228 0292
FAX: +86 771 228 0292
South China Office:
Room 402, 4/F, Tingshui Ge A, Nanhu
Garden, No.1 Bihu Rd North, Qingxiu
District, Nanning, Guangxi, China, 530028
Guangdong Joya Electric Industries Co., Ltd
CONTENTS
01
05
07
10
11
13
15
25
35
ABOUT US
LB BUSWAY SYSTEM
PRODUCT FEATURES
CATALOGUE NUMBERING SYSTEM
GENERAL PARAMETER
IP68 BUSWAY
NOTES
APPLICATIONS
INSTRUCTION OF LB BUSWAY DESIGN
26 IP68 BUSWAY GENERAL PARAMETER
29 IP68 BUSWAY INSTALLATION STEPS
30 IP68 BUSWAY APPLICATIONS
31 SERVICE SYSTEM
34 JOB REFERENCE
Certificates and Qualifications
YOUR RELIABLE BUSWAY
SOLUTION EXPERTS
01 ABOUT US02 ABOUT US
GuangDong Joya Electric Industries Co., Ltd is the leading
busway solution experts. The head office is located in GETDD,
GuangDong, China and the branches are located in all over the
word. We focus on busway sys tem so lu t ion des ign,
manufacturing, sales and service. Our products include Low
voltage compact busway, High protection degree busway, Wind
power busway, Fire resistant busway and High voltage busway.
Beside the high quality product, we also provide you the one-
station services such as layout design, project management,
on-site instruction, maintenance support and other services as
well.
Through our ambitious vision, we already set up a strong team
with all the top talents in busway industries, who are good at
management, R&D, industry operation, sales and customer
service.
Joya Electric is young company, but full of energy and people
oriented. We encourage the action of Honest, Respect, Truth
and Team work. We try our best to improve the organization,
decision making, management style, working efficiency and
effect. We are convinced a better future by our hard work in
innovation, quality and marketing.
Joya Electric will be your good business partner rather than a
simple supplier.
ISO9001ISO14001 , OHSAS18001
KEMA-KEUR CCC
Fire Resistant Test Cert i f icate
Refractory-Test Report
Applicant: Guang Dong JOYA Electric Industries Co., ltd
Product : LB Refractory Busway
Test Type: Fire-resistant
China National Center for Quality Supervison and Test of
Fixed Fire-fighting Systems and Fire-resisting Building Components
0403 ABOUT US
Cooperated with GuangDong University of Technology, we developed semi-automatic assembly line. Introduced
from Henrob and Bollhoff, the self piercing rivet technology make sure the product connected in the most reliable
and efficient way.
Advanced Manufacturing Process
Advanced R&D System
Professional Project Management System
A well educated, professional experts team will provide you the total service for project design and project
management, which make you an easy business.
Total Quality Management
With the total quality system and advanced inspection, we can make sure the produce ex-factory with
zero defect.
ABOUT US
The top experts and strict product development produce make sure the products are in the line with the related
safety and quality standards and also provide customized solutions to meet your requirements. Through
product solution design, product manufacturing, on-site service we try to avoid defects in each detail.
1 2 3 4 65
05 LB BUSWAY SYSTEM 06 LB BUSWAY SYSTEM
Smart Joint Paks, allow for
quick removal of lengths from
the busbar trunking runs for load
shifting or maintenance. It also
can be removed and relocated
on the opposite end of the
length for the last minutes job
changes.
Feeder Units, include flange end
and flange end box, which connect
to transformer or switchboard by
flexible links or solid links.
Straight Length Units, include
feeder and plug-in type. Ampere
start from 400A to 6300A can
m e e t m o s t o f t h e p o w e r
distribution needs. LB straight
length units are no Chimney
Effect.
E l b o w s , i n c l u d e f l a t w i s e ,
edgewise, Z shape, offset and
other types, adjust different
constructions.
Plug-in Units, feed the power
from the body of busway. The
protection unit inside PIU may
be circuit breaker or fuse.
H a n g e r s , f i x t h e b u s w a y,
include horizontal hanger and
spring hangers.
08 PRODUCT FEATURES07 PRODUCT FEATURESRaw Material
High purity conductor
Reliable insulation material
Aluminum-Magnesium Housing
Structures
Sandwich Structure
High IP
Sandwich Plug-in Opening
Self-piercing Riveting
Electrolytic coppers with purity over than
99.95% and conductivity over than 97.5%.
Silver plating along the length can reduce the
contact resistance and sawing section makes
the product more precision.
All bars are insulated by Mylar film from
Dupont, to prolong insulation service. The
insulation consist of two layers of heat-formed
polyester films surrounding each phase bar. It
means it can provide a solid insulation and the
excellent dielectric performance.
LB busway with fully enclosed by anti-
corrosion Al-Mg housing have been carefully
designed to reduce the weight, avoid the
hysteresis and eddy current losses.
LB busway is designed in sandwich-type
construction to provide superior heat transfer
effect and voltage drop characteristics. And
also LB busway is less space required for
installation and investment saving.
All the conduct and insulations are fully
enc losed wh ich can p rov ide a be t te r
protection degree. And totally enclosed
housing required no derating regardless of
mounting position.
Sandwich Plug-in Opening make a better heat
transfer effect in plug-in area, and also reduce
the impedance in plug-in opening.
High strength Self-piercing riveting can
reinforce the busway strength, which provide
superior protection under short circuit.
10 APPLICATIONS09 PRODUCT FEATURESTypical ApplicationStructures
Smart Joint Pak
Plug-in Unit
Joya Electric provide the plug-in units with full
mechanical interlocks, which can prevent from
wrong operation and provide a good protection
to both people and equipments. All the plug-in
jaws are silver plated can reduce the contact
resistance and make a reliable connection.
Universal accessories
a. Connect the HV/LV
transformer and Switch
board.
b. Connect two LV
Switchboards.
c. Distribute power to
each load center in a
industry environment.
d. Distribute power to each
floor in a commercial or
residential buildings.
Smart joint pak connections can be removed
and replaced easily. Double-head bolt can
facilitate the installation and thermal indicator
on the joint pak can make the inspection and
maintenance much more easier.
The design of universal accessories can
make your installation much easier, however
in horizontal or vertical.
11 INSTRUCTION OF LB BUSWAY DESIGNStep1
Step2
Below the table are designed on LB busway characteristic if you
already got the power requirement and rated working voltage.
1F
2F
3F
...
250 415 500 315 690 500
315 415 630 400 690 500
400 415 630 500 690 630
500 415 800 630 690 630
630 415 1000 800 690 800
800 415 1250 1000 690 1000
1000 415 1600 1250 690 1250
1250 415 2000 1600 690 1600
1600 415 2500 2000 690 2000
2000 415 3200 2500 690 2500
2500 415 4000 3150 690 3200
3150 415 5000 4000 690 4000
KVA V A KVA V A
12 INSTRUCTION OF LB BUSWAY DESIGN
Power Voltage Power Voltage AmpereAmpere
Step3
Step4
Step5 Select the proper LB busway based on earthing system.
All the LB busway provide intergral earth.
TNC, 3L+N
TNS, 3L+N+50%PE
TT, 3L or 3L+N
IT, 3L
Step6 Protection Degree for different invironment.
In a dry distribution room or power well, IP42 is a good choice.
In a dry room with fire pipeline above, IP54 is a good choice.
Outdoor application and those case may be attacked by rain,
IP65+canopy will be preferable.
Note: before busway is compeletely installed, there is no protection
degree at all.
The First Number The Second Number
Protection of Protection of
equipment personProtection of equipment
0 Non-protected Non-protected Non-protected
150 mm
diameter Back of handVertically dripping
212.5 mm
diameterFingers 15dripping
3 2.5 mm
diameterTools Spraying
1.0 mm
diameter4 Wire Splashing
5 WireDust-protected Jetting
6 Dust-tight Wire Power Jetting
7
8
Temporary immersion
Continuous immersion
Step7 Choose the proper plug-in units.
Step8 Routing and accessories
Calculate the total power requirement based each load
requirement. For and real case, pls contact your local
consultant to get more detail or refer to the design manual
make a right power needs calculation.
Calculate the ampere rating according to the total power
requirement.
Verify the ampere according to voltage drop requirement.
When calculate the voltage drop, the distribution coefficient
must be taken into account, details refer to page 15 of this
catalogue.
Verify the short circuit withstand capability. Normally LB
busway can afford the worst case of short circuit between
phases. For any special requirement, please contact our
local sales representative for help.
According to load requirement, select circuit breaker of fuse as
protection unit. Calculate the ampere based on load capacity.
LB plug-in units provide ampere from 16A-630A. Normally the
branch rating should be less than half of busway trunking
ratings. When the branch rating is over than 630A, we suggest
to put Flange end box plus circut breaker of fuse breaker of
fuse to protect.
Improve the layout design, try to make one routing which is
shorter and less elbow. According to actual situation, design
necessary hanger supports, LB busway requires the hangers
interval does not over than 2m. When busway pass through
two buildings, expansion units is required. Others, please
contact our local sales representative for help.
13 CATALOGUE NUMBERING SYSTEMCode LB 1 C 20 1 3
3
ST 0 020 F 12 S 12 M 12
5 A 04 2 4
5
EL 1 020 12 12 12
06
08
...
63
6
...
2
3
200 ...
50
...
50
...
50
For Elbows and Plug-in type ONLY
EXAMPLE: LB1C2013ST0020F12S22
A B C D E F G H I J K L M N O
14 CATALOGUE NUMBERING SYSTEMP C 1 H 000 1 I
Busway Plug-in Unit
6
Product Code ; 1: Compact busway
5: Fire Resistant Busway
Conductor ; C: Copper
A: Aluminum
Rating ; xx*100 A
IP Degree ; 1 IP42
2 IP54
3 IP65
4 ...
Structure ; 33L
43L+N
53L+N+50%PE
6...
Element Type ; ST: Straight Length
EL: Elbow, See right table
A Series ; LB Busway
B
C
D
E
F
G
More detail of type ; Means the elbow direction or straight length type.H
I
Element type
ST Straight Length
EF : Flatwise Elbow
EE : Edgewise Elbow
FS : Flange Start
FF : Flatwise Flange
FE : Edgewise Flange
FB : Flange End Box
DL : Turn Left Double Elbow
DR:Turn Right Double Elbow
OE : Z Shape Edgewise
OF : Z Shape Flatewise
RE : Reducer
EJ : Expansion Joint
G
Length ; xx*20 mm
P ; Plug-in Unit
I ;
O; Operate the breaker Outside
Operate the breaker Inside
1; Schneider MCCB
2; ABB MCCB
3; Changshu MCCB
4; Others
Ampere
000, Blank box without MCCB
016, 16A
025, 25A
100, 100A
125, 125A
160, 160A
200, 200A
250, 250A
400, 400A
500, 500A
630, 630A
H; High Short-Circuit MCCB
M; Medium Short-Circuit MCCB
L; Low Short-Circuit MCCB
1; IP42
2; IP54
C; MCCB
F; FUSE ( +isolator )
EXAMPLE: PC1H0001 I
15 GENERAL PARAMETERElectrical Data
P
M
PM1 M2 M3 Mn
PM2 M1 M3 MnMn
40
1.00
45
0.95
50
0.90
55
0.85
60
0.80
65
0.74
70
0.67
500 630 800 1000 1250 1600 2000 2500 3200 4000
30 30 40 50 50 50 65 80 100 120
63 63 84 105 105 105 143 176 220 264
0.1191 0.0859 0.0671 0.0587 0.0511 0.0339 0.0319 0.0268 0.0172 0.0157
0.0790 0.0569 0.0445 0.0401 0.0143 0.0256 0.0132 0.0116 0.0066 0.0064
0.1429 0.1030 0.0805 0.0711 0.0530 0.0424 0.0346 0.0292 0.0184 0.0170
0.3160 0.2277 0.1780 0.1603 0.1159 0.1178 0.1078 0.0625 0.0420 0.0376
GB7251.1,GB7251.2; IEC60439-1,IEC60439-2
RAL7045
690
1000
50/60
IP42 / IP54 / IP65
30 30 40 50 50 50 65 80 100 120 120 120
63 63 84 105 105 105 143 176 220 264 264 264
0.1032 0.0879 0.0731 0.0578 0.0471 0.0334 0.0245 0.0181 0.0127 0.0102 0.0074 0.0066
0.0439 0.0374 0.0407 0.0275 0.0252 0.0176 0.0141 0.0109 0.0087 0.0061 0.0032 0.0031
0.1122 0.0955 0.0837 0.0640 0.0534 0.0378 0.0282 0.0212 0.0154 0.0119 0.0081 0.0073
0.172 0.157 0.155 0.146 0.123 0.102 0.097 0.085 0.050 0.042 0.038 0.029
500 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300
Environment Coefficient
Aluminum Busway
Common Data
Copper Busway
16 GENERAL PARAMETER
A W (mm) H(mm)
500
102
630
102
800
102
1000 112
1250 127
1600 157
2000 187
2500 237
3200 339
4000 409
5000 539
6300 709
A W (mm) H(mm)
500
127
630
102
800
112
1000 152
1250 172
1600 217
2000 257
2500 307
3200 459
4000 589
5000
6300
Straight Length Physical Data
128
128
128
128
128
128
128
128
128
128
128
128
128
128
128
128
128
128
128
128
128
128
GB7251.1,GB7251.2; IEC60439-1,IEC60439-2
RAL7045
690
1000
50/60
Design Standard
Standard Color
Rated Voltage (V)
Rated Insulation Voltage (V)
Frequency (Hz)
Short Circuit(kA)
Peak Value(kA)
R (m/m)
X (m/m)
Z (m/m)
At fault ph-PE(m/m)
At Rated Current
Ampere (A)
Short Circuit(kA)
Peak Value(kA)
R (m/m)
X (m/m)
Z (m/m)
At fault ph-PE(m/m)
At Rated Current
Ampere (A)
V = x 3 x I x (R * cos+X *sin) x L /1000drop
distribution coefficient
I actual current (A)
R resistance (m/m)
X reactance (m/m)
L total run length(m)
concentrated load = 1.0
distributed load = 0.5
distributed load = 0.5
50
50
50
50
Figure1
Figure3
H
W
H
W
H
W
Figure2
Opening in the wall or in the floor
Rating Dimension
Figure1
Figure2
Figure3
Copper busway Aluminum busway
Rating Dimension
Figure1
Figure2
L
Special offer
Special offer
Notes:
1.The minimum length of Straight is 400mm, and increase by each 20mm.
2.Standard length for plug-in type is 1m,2m,3m, and the standard interval between two plug-in opening is 1m.
3. Dot line in the figures means the Joint covers dimension, which is over than the body by 8mm in both direction.
4.All the length shows in this catalogue means the length from joint centre to joint centre or middle of elbow.
L17.5
w+60
w
15.0
70 XX
17.5
15.0
Y1
Y2
Y2
Y1
H+75
H
7
7
L1 L2 L3 N
DD D
PE
10
5
m(1420)
75
25
60
n60
m(1420)
75
25
60
n60
60
n60 32
17 GENERAL PARAMETERFlange End Physical Data
18 GENERAL PARAMETER
286
286
286
286
286
346
346
346
346
346
W
110
120
135
160
180
225
265
315
467
597
H
123
123
123
123
123
123
153
153
153
153
X
125.5
-
77.5
85
97.5
107.5
130
150
87.5
158
Y1
-
-
-
-
-
-
87.5
125.5
158
Y2
500
630
800
1000
1250
1600
2000
2500
3200
4000
A
5000
6300
286 110 123 - -
286 110 123 - -
286 110 123 - -
286 120 123 77.5 -
286 135 123 85 -
286 165 123 100 -
346 195 153 115 -
346 245 153 140 -
346 347 153 95.5 95.5
346 417 153 113 113
346 547 153 145.5 145.5
500
630
800
1000
1250
1600
2000
2500
3200
4000
5000
6300
W H X Y1 Y2A
DimensionRating
ALUMINUM BUSWAY
COPPER BUSWAY
DimensionRating
80
80
80
80
80
80
100
100
100
100
100
100
D
-
-
-
-
-
1
1
2
1
2
3
1
n
2
2
2
2
2
4
4
6
8
12
16
16
m
500
630
800
1000
1250
1600
2000
2500
3200
4000
5000
6300
A
500
630
800
1000
1250
1600
2000
2500
3200
4000
5000
6300
80
80
80
80
80
80
100
100
100
100
-
-
-
-
1
2
2
2
2
4
6
6
8
12
16
2
2
3
2
3
D n m A
DimensionRating
COPPER BUSWAY
DimensionRating
ALUMINUM BUSWAY
Figure2
Figure1
Figure1
Figure2
Flange End
W*H, cutout dimension
Figure1
Figure2
Special offer
Special offer
Special offer
Special offer
Special offer
LL
L
L L
LL
L
L
M
M
F
M
F
L
M
L
19 GENERAL PARAMETER 20 GENERAL PARAMETERElbow Physical Data
Edgewise Elbow
T Elbow
Flatwise Elbow
Edgewise Z Elbow Double Elbow Right Edgewise Flange
Flatwise Z Elbow Double Elbow Left Flatwise Flange
200
680
560
400
360
320
280
260
220
200
100
160
140
100
480
400
260
240
200
180
160
DR/DLOFOE FE
360
740
660
540
500
460
420
400
380
360
FF
500
6300
5000
4000
3200
2500
2000
1600
1250
1000
800
630
A
160
160
160
160
160
160
160
160
160
360
360
360
360
360
360
360
360
360
360
200
900
640
500
440
340
280
260
220
200
200
200
100
120
100
100
740
520
380
320
220
180
160
140
160 360
980
780
640
580
480
420
400
380
360
360
360160
160
160
160
160
160
160
160
160
160
160
360
360
360
360
360
360
360
360
360
360
360
360
DR/DLOFOE
500
6300
5000
4000
3200
2500
2000
1600
1250
1000
800
630
FE FFA
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
280
920
700
560
500
400
340
320
300
280
280
280
280
280
280
280
920
700
560
500
400
340
320
300
280
280
280
280
280
280
280
280
280
280
280
280
500
6300
5000
4000
3200
2500
2000
1600
1250
1000
800
630
A
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
280
280
660
580
460
420
380
340
280
280
280
280
280
280
280
280
280
280
500
6300
5000
4000
3200
2500
2000
1600
1250
1000
800
630
A
300
320
280
280
660
580
460
420
380
340
300
320
L MinRating L Max
COPPER BUSWAY
EE TF EF
L MinRating L Max
ALUMINUM BUSWAY
EE TF EF
Note: the total length of all the elbow arms cannot
be over than 3000mm.
M min F minRating
ALUMINUM BUSWAY
M min F minRating
COPPER BUSWAY
Note: the total length of all the elbow arms must
be less than 3000mm.
Special offer
Special offer
Special offer
Special offer
21 GENERAL PARAMETERPlug-in Units Operation
22 GENERAL PARAMETERY
ZX
X
Rating
Below 160
X
280
280
Y
450
450200-250
315-630 380 780
Z
240
240
300
W
HL
Cable Flange Box
Flange Box, connect cable and busway in one
enclosed box, to make sure a good protection
to connection area. It can also be made as on
special offer with high ampere MCCB or ACB.
Plug-in Units will provide full offer equipped
with Schneider NS Series, ABB Tmax or
Isomax MCCB.
Size: Min:300x300x300
Accessories Physical Data
Operate Inside
The Circuit Breaker is set inside, opening the plug-in
unit to turn it off.
Operate Outside
Operating the plug-in unit when the interlock have
caught the busway completely already.
Interlock
Between busway and plug-in unit
Between plug-in unit door and circuit break
Max:2500x2500x1000
Joya can also offer fuse protection. Special offer,
please contact our local sales representative.
23 GENERAL PARAMETERAccessories Physical Data
Connect the high power and low
power run. Reduce to half or derate
two ratings is the preferable choice.
W
H
1100
Expansion Joint
Expansion Joint are mainly applied in
the building expansion area. For other
applications please contact our local
safes for more support.
600
H1
H2
Rating
1250400
16001000
20001250
25001600
32002000
40002500
1000400
H1
111
111
126
126
126
156
156
186
186
236
236
338
338
408
1250800
408
538
H2
101
101
101
101
101
101
111
111
126
126
156
156
186
186
236
236
1000630
1250630
1600800
20001000
25001250
32001600
40002000
50002500
Notes:
Joya can also provide special
reduce with MCCB or FUSE
protection.
Rating
1250
3200
4000
800
H
360
370
385
415
445
495
600
670
W
465
465
465
465
580
580
580
580
1000
1600
2000
2500
Reducer
H+8
13
4
Height +4733.5 33.52323 124
24 GENERAL PARAMETERAccessories Physical Data
Horizontal Hanger
Carrying one or more busways when busways
installed horizontal.
Carrying one or more installed vertical busways
and reduce the transmission of building forces.
The busways height +119
500
3200
2500
2000
1600
1250
1000
800
630
4000
5000
6300
500
3200
2500
2000
1600
1250
1000
800
630
4000
The end closed is installed
during the end of the
busway is not used.
COPPER BUSWAY
ALUMINUM BUSWAY
Rating Spring Hanger
NOTE: Channel by customer.
Rating Spring Hanger
SH03
SH02
SH01
SH02
SH01
SH03
Spring Hanger
LB IP68 BUSWAY
Electrical Data
Four-proof
GB7251.1,GB7251.2; IEC60439-1,IEC60439-2
1000
50/60
30 30 50 50 50 50 80 80 80
63 63 105 105 105 105 176 176 176
0.1265 0.0948 0.0690 0.0578 0.0405 0.0311 0.0225 0.0181 0.0125
0.0947 0.0703 0.0517 0.0588 0.0411 0.0317 0.0229 0.0225 0.0155
0.1580 0.1180 0.0862 0.0825 0.0577 0.0444 0.0321 0.0289 0.0199
1000
630 800 1000 1250 1600 2000 2500 3200 4000
LB IP68 Busway is cased fully by superior compound insulation which is made up of epoxy resin and inert
minerals, with the highest protection level. LB IP68 Busway also provides superior heat transfer effect and
chemical stability.
Common Data
Design Standard
Rated Voltage (V)
Rated Insulation Voltage (V)
Frequency (Hz)
Short Circuit(kA)
Peak Value(kA)
R (m/m)
X (m/m)
Z (m/m)
At Rated Current
Ampere (A)
Wa t e r P r o o f : W i t h I P X 8 , L B I P 6 8 B u s w a y c a n b e u s e d i n w a t e r.
F i r e P r o o f : W i t h t h e h i g h q u a l i t y c o m p o u n d i n s u l a t i o n , L B I P 6 8 B u s w a y c a n s t a n d h i g h
t e m p e r a t u r e a n d n o C h i m n e y E f f e c t " a n d w e l l a s H a l o g e n f r e e d u r i n g t h e
f i r e .
C o r r o s i o n P r o o f : W i t h t h e a n t i - c o r r o s i o n h o u s i n g , L B I P 6 8 B u s w a y a v o i d t h e l o s s f r o m
e l e c t r o c h e m i s t r y a n d c h e m i s t r y c o r r o s i o n .
E x p l o s i o n P r o o f : W i t h t h e f u l l y e n c l o s u r e , L B I P 6 8 B u s w a y s e p a r a t e t h e a i r a n d t h e c i r c u i t t o
m a k e s u r e i t w o n ' t g e t e x p l o d e .
26
L
H
W
H
W
IP68 BUSWAY GENERAL PARAMETER
The standard length of LB Fire Resistant busway is from 0.4m to 3.0m (length=x+20mm), and the longest
length is 6m.
Figure1 Figure2
Straight Length Physical Data
Rating Demension
A W (mm) H(mm)
630
800
1000
1250
1600
2000
2500
3200
4000
93/106
85
85
85
100
130
160
210
282
382
W: 3L+N=93
3L+N+50%PE=106
Figure1
Figure2
I 68 BuswayP
DD n m A
80
80
80
80
80
120
120
120
120
-
-
-
-
1
1
2
1
2
2
2
2
2
4
4
6
8
12
630
800
1000
1250
1600
2000
2500
3200
4000
Rating Demension
Figure1
60
nx60
M-(14x20)
50
25
Figure1
M-(14x20)
nx60
60
nx60
60
50
25
Figure2
Flange End Physical Data
27 IP68 BUSWAY GENERAL PARAMETER 28 IP68 BUSWAY GENERAL PARAMETER
L MinRating
FeederA T ElbowFlatwise
Elbow
Edgewise
Elbow
M Min
Edgewise Z
Elbow
280
280
280
280
280
280
280
280
280
560
500
400
340
320
300
280
280
280
280
280
280
560
500
400
340
320
300
280
280
280
280
280
280
280
280
2804000
3200
2500
2000
1600
1250
1000
800
630 100
100
120
140
160
180
220
320
380
200
200
200
500
440
340
280
260
220
Double
Elbows
Feeder T Elbow Flatwise Elbow
Edgewise Elbow Edgewise Z Elbow Double Elbows
Elbow Physical Data
Figure2
29 IP68 BUSWAY INSTALLATION STEPS1st step:
Link up two busways
and keep about 24mm space.
2nd step:
Assemble the smart joint-pak
and wring the double-head bolts.
3rd step:
Pay attention to seal the end
during install the joint-pak mold.
4th step:
Casting
Note: I
Joya refractory
castables need to be stirred adequately and
tapped the mold during casting.
n order to make the refractory castables is
filled up the smart joint-pak,
240mm
30 PI 68 BUSWAY APPLICATIONS
Ship Factory Petroleum and Chemical Industry
Cable trench Buildings
LB IP68 busway is applied extensively to each special areas, with high quality four proof function.
Water Proof: Outdoor, Cable trenches, Corridors etc.
Fire Proof: Fire bureau, Fire department etc.
Corrosion Proof: Chemical industry etc.
Explosion Proof: Petroleum industry, Chemical industry etc.
31 SERVICE SYSTEMYour Reliable Busway Solution Experts
Service for future
Customer complaint
Verification
Missing-link installment
Missing-link measurement
On-site instrution
Logistic service Final inspection
Manufacturing
Material planning
Oder process
Measurement
Project planning
Solution design
Project consult
On-site
servicesManufacturing
On-going
service
After sales
service
Pre-sale
support
Project
supportCustomer
Together with the high quality product we will also provide you the one-station services such as layout design,
project management, on-site instruction, maintenance support and other service for your concerns.
Pre-sale: Project consult, Solution design
Project support: Project planning, Measurement, Order process
Manufacturing: Material planning, Manufacturing, Final inspection
On-site service: Logistic service, On site instruction
On-going service: Missing-link measurement, Missing link installment, Verification
After-sales: Customer complaint, Service for future
After electrifying
0.5 year after
electrifying
Checking
the busway
temperature
Maintaining
and training
1 years after
electrifying
Checking
and
maintaining
Extended
every year
Doing an entire
maintenance
T h e b u s w a y
inner and outer
maintenance
Period Project Contents
32 SERVICE SYSTEMService actions
NOTE: Special offer please contact our local sales representative.
Training the
maintenance
staff
C h e c k i n g t h e
b u s w a y s t a t u s
and any potential
defect
C h e c k i n g t h e
busway connection,
running status and
any potential defect
Service commitment
33 SERVICE SYSTEM
Reply
within 24hrs
(Overseas)
Timely on-site
service (Overseas)
Reply within
2hrs (HK)
On-site service
in 24hrs (HK)
Your Reliable Busway Solution Experts
34 JOB REFERENCE Industrial Building
HITACHI Chian Tobacco GuangDong Industrial TianAn Cyber
Commercial Building
Sanya International Exchange CenterShunde Garden HotelRegal Palace Resort Hotel
Public Building
New World China Land Shenzhen Rui Zhi Building Pearl River New-town N5-1
36 NOTES35 NOTES GuangDong Joya Electric Industries Co., LtdYour reliable busway solution expert. GuangDong Joya Electric Industries Co., LtdYour reliable busway solution expert.