2
Customised Expansion Joints for High Specifications Structures © The Trajan Group 2014-2017. All Rights Reserved. JOINT SYSTEMS™ FAÇADE INTERACTION SYSTEM™ As a result of extensive design and testing, we are glad to be introducing to the Architectural World, our Joint Systems™ Façade Interaction System. Joint Systems™, through utilizing many years of construction knowledge, created with the first system to ever use the increased silicone thickness on the external bellows coating. Joint Systems, expansion joint arm of The Trajan Group P/L, engineered this in conjunction with Aurecon, HKS and several other World-class Engineers and Architects; combining the best of both physical theory and relative mechanics when dealing with both high-risk curtain walls and standard curtain wall projects. Running Projects include the New Perth Childrens’ Hospital, and the world’s most technologically advanced, the New Royal Adelaide Hospital. General Arrangement | Specifications Figure 1. General Arrangement, < -/+50% Movement, Non Fire rated Figure 2. General Arrangement, < -/+50% Movement Fire Rated General: - Typical ceiling level: 2700mm - Typical U/S slab level: 4200mm - Typical slab: Lysaght Bondek, or similar, + 300mm concrete - Typical ceiling: Knauf grid ceiling (CEI-01), or similar, - Typical wall finish: paint - Typical overall width of fin: 92mm - Wall insulation: 50mm Earthwool, or similar, (11kg/m3) (low height) - Ceiling insulation: 50mm Earthwool, or similar, (11kg/m3) (600mm wide stripes to each side of low height grade 3 walls) - Fin insulation: 50mm Earthwool, or similar, (14kg/m3) (low height)

JOINT SYSTEMS™ FAÇADE INTERACTION SYSTEM™ ·  · 2017-10-12Title: Microsoft Word - joint-systems-general-arrangement-specs.docx Created Date: 10/12/2017 12:15:46 AM

  • Upload
    dinhnhi

  • View
    221

  • Download
    5

Embed Size (px)

Citation preview

Customised Expansion Joints for High Specifications Structures

©TheTrajanGroup2014-2017.AllRightsReserved.

JOINTSYSTEMS™FAÇADEINTERACTIONSYSTEM™As a result of extensive design and testing, we are glad to be introducing to the Architectural World, our Joint Systems™ Façade Interaction System. Joint Systems™, through utilizing many years of construction knowledge, created with the first system to ever use the increased silicone thickness on the external bellows coating. Joint Systems, expansion joint arm of The Trajan Group P/L, engineered this in conjunction with Aurecon, HKS and several other World-class Engineers and Architects; combining the best of both physical theory and relative mechanics when dealing with both high-risk curtain walls and standard curtain wall projects. Running Projects include the New Perth Childrens’ Hospital, and the world’s most technologically advanced, the New Royal Adelaide Hospital. GeneralArrangement|Specifications

Figure1.GeneralArrangement,<-/+50%Movement,NonFireratedFigure2.GeneralArrangement,<-/+50%MovementFireRated

General: - Typical ceiling level: 2700mm - Typical U/S slab level: 4200mm - Typical slab: Lysaght Bondek, or similar, + 300mm concrete - Typical ceiling: Knauf grid ceiling (CEI-01), or similar, - Typical wall finish: paint - Typical overall width of fin: 92mm - Wall insulation: 50mm Earthwool, or similar, (11kg/m3) (low height) - Ceiling insulation: 50mm Earthwool, or similar, (11kg/m3) (600mm wide stripes to each side of low height grade 3 walls) - Fin insulation: 50mm Earthwool, or similar, (14kg/m3) (low height)

Customised Expansion Joints for High Specifications Structures

©TheTrajanGroup2014-2017.AllRightsReserved.

Acoustic Grade 3 Partitions: - Acoustic Grade 3: Rw=43 to 45 - Partition façade junction: see detail 2 on 065 - Low height finn: ends 300mm above ceiling level - Low height wall: ends 100mm above ceiling level - Insulation above ceiling: 600 mmm wide insulation required to both sides of grade 3 wall - Width of wall: 118 NOM. (2x 13mm Knauf QuadShield, or similar,+ 92mm Knauf Steel Stud, or similar, 0.75 BMT at 600 Ctrs.) Acoustic Grade 4 Partitions: - Acoustic grade 4: Rw=48 to 52 - Partition façade junction: see detail 3 on 065 - Partition and fin to be full height to U/S slab + deflection head on top - Wall/fin insulation: 50mm Earthwool, or similar, (14kg/m3) (full height) - Width of wall: 131 NOM. (3x 13mm Knauf QuadShield, or similar, + 92mm Knauf Steel Stud, or similar, 0.75 BMT at 600 Ctrs ) Typical façade mullion: - 6063-T6 (aluminium alloy/temper) coated with polyester powder coating - Aluminium plates coated with polyester powder coating to match finish of façade mullion Max movement and gap sizes: - 17mm in both directions - 35mm gap

CONTACTOUREXCLUSIVEJOINTSYSTEMS™REPRESENTATIVE,MASON&MAKERhttps://vicrestorations.com

Wecanhelpdesign,supplyandinstallyourFaçadeInteractionSystem™