The Domestic Cables & wiring catalogue contains all indoor cables, and copper conductors insulated with PVC material. These cables include regular wires and cables, fire retardant cables (FR), low smoke fumes cables (LSF), halogen free cables and flexible cables with sizes ranging from �.5 mm2 up to 630 mm2.
Single core cables, solid, stranded or flexible circular copper conductors as per BS 6004 standard are used for installation in surface mounted or embedded conduits, or similar closed systems. These cables are suitable for use in channels with cover, fixed protection installation or on lighting fittings and inside appliances, switchgear and control gear.
PVC insulated cord (NYZ) as per VDE 028� standard are used in dry rooms for fixed installation where particular flexibility is required. They can be laid in conduits over or under the walls as well as steel support brackets. These are used for light portable appliances such as lamps, TVs sets and table fans.
Flat-Twin and Flat-Three core cable as per BS 6004 standard are used for indoor fixed installations in dry locations, laid over walls, surface clipped or embedded in plaster, or over support brackets in domestic, commercial and industrial applications.
Indoor Multi core flexible cables as per BS 6500 standard are used in domestic premises, kitchens, offices, and household appliances, including damp situation. They are suitable for connecting washing machines, spin extractors, refrigerators, portable lamps, fans, vacuum cleaners, TV and household heating and ventilating apparatus, where the cord can not be in touch with surface temperature exceeding 85oC.
THHN/THWN AWG wires are widely used in new constructions. These wires are suitable for lighting and power purposes in industrial, commercial and residential buildings. Type THHN/THWN wires are designed to operate at conductor temperatures of 75oC for 600 volts service in wet and dry locations.Type THHN/THWN wires are also suitable for control circuits, machine tools and appliances. The Nylon jacket provides mechanical ruggedness and resistance to Acids, Alkalis, Oils, Gasoline and Chemicals.
2
JORDAN NEW CABLE COMPANY DOMESTIC CABLES
450 / 750 Volts - Copper Conductor PVC Insulated
Cu/PVC - SOLID CONDUCTOR IEC 60227 & BS 6004
Harmonized Code Designation: H07V-U
Code No.
Nominal Area
Construction Insulation Thickness
Approx. Overall Diameter
Approx. Cable Weight
Standard Length
Sq. mm No. / mm mm mm Kg/Km (Mt)
B32-0��0600�-�00xx-2 �.0 � / �.�3 0.60 2.3 �4 9�.4 C
B32-0��0700�-�00xx-2 �.5 � / �.38 0.70 2.8 2� 9�.4 C
B32-0��0900�-�00xx-2 2.5 � / �.78 0.80 3.4 33 9�.4 C
B32-0����00�-�00xx-2 4 � / 2.25 0.80 3.9 48 9�.4 C
B32-0���200�-�00xx-2 6 � / 2.76 0.80 4.4 68 9�.4 C
B32-0���300�-�00xx-2 �0 � / 3.57 �.00 5.6 ��3 9�.4 C
Color Black Blue Brown Green/Yellow Gray Green
xx Color Code BK BL BR GY GR GN
Color Orange Pink Red Red/Yellow Turqos Violet
xx Color Code OR PK RD RY TR VL
Color White Yellow
xx Color Code WT YL
C : Coil
Application:
Construction:
used for installation in surface mounted or embedded conduits or similar closed systems; it is suitable for use in channels with cover, as well as it is suitable for fixed protected installation in or on light fittings and inside appliances, switchgear and control gear, for voltages up to �000V a.c. or up to 750 V to earth d.c.
Plain annealed copper conductor class � as per BS 6360, or IEC 60228 PVC insulation type TI� colored as per BS 6746.
3
Application:
Construction:
used for installation in surface mounted or embedded conduits or similar closed systems; it is suitable for use in channels with cover, as well as it is suitable for fixed protected installation in or on light fittings and inside appliances, switchgear and control gear, for voltages up to �000V a.c. or up to 750 V to earth d.c.
Plain annealed copper conductor class 2 as per BS 6360, or IEC 60228 PVC insulation type TI� colored as per BS 6746.
JORDAN NEW CABLE COMPANY DOMESTIC WIRING 450 / 750 Volts - Copper Conductor PVC Insulated
CU/PVC - STRANDED CONDUCTOR IEC 60227 & BS 6004
Harmonized Code Designation: H07V-R
Code No.Nominal
AreaConstruction
Nominal Insulation Thickness
Approx. Overall
Diameter
Approx. Cable Weight
Standard Length
Sq. mm No. / mm mm mm Kg/Km (Mt)B32-0��06002-�00xx-2 �.0 7 / 0.44 0.60 2.5 �4.5 9�.4 CB32-0��07002-�00xx-2 �.5 7 / 0.53 0.70 3.0 2�.3 9�.4 CB32-0��09002-�00xx-2 2.5 7 / 0.67 0.80 3.6 33.0 9�.4 CB32-0����002-�00xx-2 4 7 / 0.85 0.80 4.2 48.5 9�.4 CB32-0���2002-�00xx-2 6 7 / �.04 0.80 4.7 67.7 9�.4 CB32-0���3002-�00xx-2 �0 7 / �.34 �.00 6.0 ��3 9�.4 CB32-0���4002-�00xx-2 �6 7 / �.68 �.00 7.� �66 9�.4 CB32-0���5003-�00xx-2 25 7 / 2.25 �.20 8.3 260 9�.4 CB32-0���6003-�00xx-2 35 7 / 2.65 �.20 9.4 356 9�.4 CB32-0���7003-�00xx-J 50 7 / 3.00 �.40 �0.9 484 �000 DB32-0���8003-�00xx-J 70 �9 / 2.25 �.40 �2.5 676 �000 DB32-0���9003-�00xx-J 95 �9 / 2.65 �.60 �4.8 943 �000 DB32-0��20003-�00xx-J �20 37 / 2.�3 �.60 �6.� ��6� �000 DB32-0��2�003-�00xx-J �50 37 / 2.35 �.80 �8.� �463 �000 DB32-0��22003-�00xx-J �85 37 / 2.65 2.00 20.0 �8�2 �000 DB32-0��23003-�00xx-J 240 37 / 3.00 2.20 22.8 2365 �000 DB32-0��24003-�00xx-J 300 37 / 3.35 2.40 25.3 2955 �000 DB32-0��25003-�00xx-J 400 6� / 2.96 2.60 28.6 3766 500 DB32-0��26003-�00xx-J 500 6� / 3.32 2.80 32.2 4777 500 DB32-0��27003-�00xx-J 630 6� / 3.75 2.80 35.4 6024 500 D
Color Black Blue Brown Green/Yellow Gray Greenxx Color Code BK BL BR GY GR GN
Color Orange Pink Red Red/Yellow Turquoise Violetxx Color Code OR PK RD RY TR VL
Color White Yellowxx Color Code WT YL
C : Coil / D : Drum
4
JORDAN NEW CABLE COMPANY DOMESTIC WIRING 450 / 750 Volts - Copper Conductor PVC Insulated
Cu/PVC - FLEXIBLE CONDUCTOR IEC 60227 & BS 6004
Harmonized Code Designation: H07V-K
Code No.Nominal
Area *** Construction
Insulation Thickness
Approx. Overall
Diameter
Approx. Cable
Weight
Standard Length
Sq. mm No. / mm mm mm Kg/Km (Mt)B22-0��05005-�00xx-2 0.75 22 / 0.20 0.60 2.3 ��.2 9�.4 CB22-0��06005-�00xx-2 �.0 29 / 0.20 0.60 2.4 �3.7 9�.4 CB32-0��07005-�00xx-2 �.5 30 / 0.24 0.70 2.9 20.3 9�.4 CB32-0��09005-�00xx-2 2.5 48 / 0.24 0.80 3.5 3�.6 9�.4 CB32-0����005-�00xx-2 4 78 / 0.24 0.80 4.0 47.0 9�.4 CB32-0���2005-�00xx-2 6 �20 / 0.24 0.80 4.6 66.9 9�.4 CB32-0���3005-�00xx-2 �0 �92 / 0.24 �.00 5.8 �08.� 9�.4 CB32-0���4005-�00xx-2 �6 3�2 / 0.24 �.00 6.9 �66 9�.4 CB32-0���5005-�00xx-2 25 �96 / 0.40 �.20 8.9 253 9�.4 CB32-0���6005-�00xx-2 35 276 / 0.40 �.20 �0.� 355 9�.4 CB32-0���7005-�00xx-J 50 396 / 0.40 �.40 �2.0 487 �000 DB32-0���8005-�00xx-J 70 360 / 0.50 �.40 �3.8 675 �000 DB32-0���9005-�00xx-J 95 475 / 0.50 �.60 �5.8 898 �000 DB32-0��20005-�00xx-J �20 592 / 0.50 �.60 �7.3 ���� �000 DB32-0��2�005-�00xx-J �50 756 / 0.50 * �.80 �9.5 �405 �000 DB32-0��22005-�00xx-J �85 925 / 0.50 * 200 2�.6 �789 �000 DB32-0��23005-�00xx-J 240 �22� / 0.50 * 2.20 24.6 23�5 �000 DB32-0��24005-�00xx-J 300 �525 / 0.50 * 2.40 ** 27.4 2927 �000 D
Used for installation in surface mounted or embedded conduits or similar closed systems; it is suitable for use in channels with cover, as well as it is suitable for fixed protected installation in or on light fittings and inside appliances, switchgear and control gear, for voltages up to �000V a.c. or up to 750 V to earth d.c.
Plain annealed copper conductor class 5 as per BS 6360, or IEC 60228 PVC insulation type TI� colored as per BS 6746.
Application:
Construction:
* Conceptual Construction** General as per BS 6004*** Extra Flexible Coductors can be manufactured using 0.24mm wire diameter
Color Black Blue Brown Green/Yellow Gray Greenxx Color Code BK BL BR GY GR GN
Color Orange Pink Red Red/Yellow Turquoise Violetxx Color Code OR PK RD RY TR VL
Color White Yellowxx Color Code WT YL
C : Coil / D : Drum
5
JORDAN NEW CABLE COMPANY DOMESTIC WIRING 300 / 300 Volts - PVC Insulated Flexible Cord
Cu/PVC - NYZ VDE 028�:�985
Code No.
Nominal Area
Construction Insulation Thickness
Approx. Overall Dimensions
Approx. Cable Weight
Standard Length
Sq. mm No. / mm mm mm Kg/Km (Mt)
B�5-02�0�005-�00WT-2 2 x 0.25 �4 / 0.�5 0.70 2.25 x 4.50 �4.2 9�.4 C
B�5-02�02005-�00WT-2 2 x 0.38 2� / 0.�5 0.80 2.40 x 4.80 �9.3 9�.4 C
B�5-02�04005-�00WT-2 2 x 0.50 �5 / 0.20 0.80 2.50 x 5.00 22.5 9�.4 C
B�5-02�05005-�00WT-2 2 x 0.75 22 / 0.20 0.80 2.70 x 5.40 27.7 9�.4 C
B�5-02�06005-�00WT-2 2 x �.00 29 / 0.20 0.80 2.84 x 5.70 3�.� 9�.4 C
Application:
Construction:
Used in dry room for fixed installation where particular flexibility is required. They can be laid in conduits over or under the walls as well as steel support brackets. These are used for light portable appliances such as lamps, TV sets and table fans.
Plain annealed copper conductor class 5 as per BS 6360, or IEC 60228The conductors shall be laid parallel and covered with PVC insulation type TI2 white colored as per BS 6746.The insulation shall be provided with a groove on each side between the conductors to facilitate separation of the cores.
C : Coil
6
Application:
Construction:
These cables are used for installation in surface mounted or embedded conduits, or similar closed systems.
Plain annealed copper conductor class � as per BS 6360, or IEC 60228 PVC insulation type TI� colored as per BS 6746.The insulated conductors shall be laid in parallel and covered with PVC sheath type TM� black colored as per BS 6746.The sheath shall be closely fitting but shall adhere to the cores, the sheath shall be provided with a groove on each side between the cores to facilitate separation of the cores.
Core Identification: Twin: Black & Blue Three-core: Black, Blue (Center) & Green.
JORDAN NEW CABLE COMPANY DOMESTIC WIRING 220 / 380 Volts - PVC Insulated PVC Sheathed
Cu/PVC/PVC - FLAT TWIN & THREE CORES (NYIFY) DIN VDE 0250:�99�
Code No.
Nominal Area
Construction Ins. Thick.Nominal Sheath Thick.
Approx. Overall
Dimensions
Approx. Cable
Weight
Standard Length
Sq. mm No. / mm mm mm mm Kg/Km (Mt)
B35-02�0700�-�0NBK-2 2 x �.5 � / �.38 0.40 0.80 3.8 x �0.8 63 9�.4 C
B35-02�0900�-�0NBK-2 2 x 2.5 � / �.78 0.50 0.90 4.6 x �2.4 96 9�.4 C
B35-02���00�-�0NBK-2 2 x 4.0 � / 2.25 0.60 0.90 5.3 x �3.9 �34 9�.4 C
B35-03�0700�-�0NBK-2 3 x �.5 � / �.38 0.40 0.80 3.8 x �7.� 95 9�.4 C
B35-03�0900�-�0NBK-2 3 x 2.5 � / �.78 0.50 0.90 4.6 x 22.3 �49 9�.4 C
B35-03���00�-�0NBK-2 3 x 4.0 � / 2.25 0.60 0.90 5.3 x 24.4 200 9�.4 C
C : Coil
7
JORDAN NEW CABLE COMPANY DOMESTIC CABLES300/500 Volts - PVC Insulated PVC sheathed Flat Cables
Cu/PVC/PVC - FLAT TWIN & FLAT THREE CORES BS 6004:2000
Code No.Nominal
AreaConstruction Ins. Thick.
Nominal Sheath Thick,
Approx. Overall
Dimensions
Approx. Cable
Weight
Standard Length
Sq. mm No. / mm mm mm mm Kg/Km (Mt)
T22-02�06002-�0NGR-2 2 x �.0 7 / 0.44 0.60 0.90 4.40 x 6.90 52 9�.4 C
T22-02�07002-�0NGR-2 2 x �.5 7 / 0.53 0.70 0.90 4.80 x 7.80 70 9�.4 C
T22-02�09002-�0NGR-2 2 x 2.5 7 / 0.67 0.80 �.00 5.60 x 9.20 �04 9�.4 C
T22-02���002-�0NGR-2 2 x 4.0 7 / 0.85 0.80 �.00 6.20 x �0.30 �38 9�.4 C
T22-02��2002-�0NGR-2 2 x 6.0 7 / �.04 0.80 �.�0 6.92 x ��.70 �89 9�.4 C
T22-02��3002-�0NGR-2 2 x �0 7 / �.34 �.00 �.20 8.42 x �4.50 300 9�.4 C
T22-03�06002-�0NGR-2 3 x �.0 7 / 0.44 0.60 0.90 4.32 x 9.40 75 9�.4 C
T22-03�07002-�0NGR-2 3 x �.5 7 / 0.53 0.70 0.90 4.80 x �0.80 �02 9�.4 C
T22-03�09002-�0NGR-2 3 x 2.5 7 / 0.67 0.80 �.00 5.60 x �2.80 �52 9�.4 C
T22-03���002-�0NGR-2 3 x 4.0 7 / 0.85 0.80 �.�0 6.40 x �4.70 �95 9�.4 C
T22-03��2002-�0NGR-2 3 x 6.0 7 / �.04 0.80 �.�0 6.92 x �6.40 257 9�.4 C
Application:
Construction:
For Fixed Installation in dry or damp premises; suitable for installation in walls, on boards and in channels or embedded in plaster.
Plain annealed copper conductor class 2 colored as per BS 6360, or IEC 60228 PVC insulation type TI� colored as per BS 6746.PVC sheath type 6 grey colored as per BS 6746. The sheath shall be closely fitting but shall not adhere to the cores and in the case of twin and three-core, the cores shall be laid parallel.
Core Identification: Twin: Red & Black.Three-core: Red, Yellow (Center) & Blue.
C : Coil
8
JORDAN NEW CABLE COMPANY DOMESTIC CABLES300/300 Volts - PVC Insulated PVC Sheathed Flexible Cables
Cu/PVC/PVC - Light Flexible Cables BS 6500:2000
Harmonized Code Designations:H03VVH2-F - Parallel Cords
H03VV-F - Circular Cords
Code No.Nominal
AreaConstruction Ins. Thick.
Nominal Sheath Thick.
Approx. Overall
Diameter
Approx. Cable
Weight
Standard Length
Sq. mm No. / mm mm mm mm Kg/Km (Mt)
F�2-02�04005-�0NWT-2 2 x 0.50 �5 / 0.20 0.50 0.60 5.0 47 9�.4 C
F�2-02�05005-�0NWT-2 2 x 0.75 22 / 0.20 0.50 0.60 5.4 55 9�.4 C
F�2-03�04005-�0NWT-2 3 x 0.50 �5 / 0.20 0.50 0.60 5.3 55 9�.4 C
F�2-03�05005-�0NWT-2 3 x 0.75 22 / 0.20 0.50 0.60 5.7 65 9�.4 C
F�2-04�04005-�0NWT-2 4 x 0.50 �5 / 0.20 0.50 0.60 5.8 68 9�.4 C
F�2-04�05005-�0NWT-2 4 x 0.75 22 / 0.20 0.50 0.60 6.3 8� 9�.4 C
Application:
Construction:
These cords are used in domestic premises, kitchens, offices, for household appliances, including damp situation. They are suitable for connecting washing machines, spin extractor, refrigerators, portable lamps, fans, vacuum cleaners, TV and household heating and ventilating apparatus, where the cord can not be in touch with a surface temperature exceeding 85ºC.
Plain annealed copper conductor class 5 as per BS 6360, or IEC 60228PVC insulation type TI2 colored as per BS 6746.PVC sheath TM2 white colored as per BS 6746.The sheath shall be closely fitting but shall not adhere to the cores
Core Identification: Two-core: Blue & BrownThree-core: Green/Yellow, Blue,& Brown.Four-core: Green/Yellow, Blue, Brown, & Black.
C : Coil
9
JORDAN NEW CABLE COMPANY DOMESTIC CABLES300/500 Volts - PVC Insulated PVC sheathed Flexible Cables
Cu/PVC/PVC - Ordinary Flexible Cables BS 6500:2000
Harmonized Code Designations: H05VVH2-F - Parallel Cords
H05VV-F - Circular Cords
Code No.Nominal
AreaConstruction Ins. Thick.
Nominal Sheath Thick.
Approx. Overall
Diameter
Approx. Cable
Weight
Standard Length
Sq. mm No. / mm mm mm mm Kg/Km (Mt)F22-02�06005-�0NWT-2 2 x �.0 29 / 0.20 0.60 0.80 6.5 63 9�.4 CF22-02�07005-�0NWT-2 2 x �.5 30 / 0.24 0.70 0.80 7.5 86 9�.4 CF22-02�09005-�0NWT-2 2 x 2.5 48 / 0.24 0.80 �.00 9.� �3� 9�.4 CF22-02���005-�0NWT-2 2 x 4.0* 78 / 0.24 0.80 �.20 �0.5 �86 9�.4 CF22-02��2005-�0NWT-2 2 x 6.0* �20 / 0.24 0.80 �.20 ��.7 244 9�.4 CF22-03�06005-�0NWT-2 3 x �.0 29 / 0.20 0.60 0.80 6.9 76 9�.4 CF22-03�07005-�0NWT-2 3 x �.5 30 / 0.24 0.70 0.90 8.� �08 9�.4 CF22-03�09005-�0NWT-2 3 x 2.5 48 / 0.24 0.80 �.00 9.6 �59 9�.4 CF22-03���005-�0NWT-2 3 x 4.0* 78 / 0.24 0.80 �.20 ��.2 230 9�.4 CF22-03��2005-�0NWT-2 3 x 6.0* �20 / 0.24 0.80 �.40 �2.8 3�8 9�.4 CF22-04�06005-�0NWT-2 4 x �.0 29 / 0.20 0.60 0.90 7.7 94 9�.4 CF22-04�07005-�0NWT-2 4 x �.5 30 / 0.24 0.70 �.00 9.� �38 9�.4 CF22-04�09005-�0NWT-2 4 x 2.5 48 / 0.24 0.80 �.�0 �0.8 203 9�.4 CF22-04���005-�0NWT-2 4 x 4.0* 78 / 0.24 0.80 �.40 �2.6 297 9�.4 CF22-04��2005-�0NWT-2 4 x 6.0* �20 / 0.24 0.80 �.40 �4.� 397 9�.4 C
*Generally as per BS 6500:2000
Application:
Construction:
These cords are used in domestic premises, kitchens, offices, for household appliances, including damp situation. They are suitable for connecting washing machines, spin extractor, refrigerators, portable lamps, fans, vacuum cleaners, TV and household heating and ventilating apparatus, where the cord can not be in touch with a surface temperature exceeding 85ºC
Plain annealed copper conductor class 5 as per BS 6360, or IEC 60228PVC insulation type TI2 colored as per BS 6746.PVC sheath TM2 white colored as per BS 6746. The sheath shall be closely fitting but shall not adhere to the cores
Core Identification: Two-core: Blue & BrownThree-core: Green/Yellow, Blue, & Brown.Four-core: Green/Yellow, Blue, Brown, & Black.
C : Coil
�0
JORDAN NEW CABLE COMPANY DOMESTIC WIRING600 Volts - THHN / THWN AWG WIRES
Cu/PVC/NYLON UL-83, UL-�58�
Code No. AWGEquiv. Area
Conductor Cons.Ins.
Thick.
Nylon Jacket Thick.
Approx. Overall
Diameter
Approx. Cable
Weight
Standard Length
Sq. mm No. / mm mm mm mm Kg/Km (Mt.)
B64-0��96002-800xx-5 �8* 0.82 �6 / 0.254 0.38 0.�� 2.3 �2.0 �52.4 C (500ft)
B64-0��34002-800xx-5 �6* �.3� 26 / 0.254 0.38 0.�� 2.6 �7.0 �52.4 C (500ft)
B64-0��33002-800xx-5 �4 2.08 �3x0.404 + 6x0.296 0.38 0.�� 2.9 24.8 �52.4 C (500ft)
B64-0��32002-800xx-5 �2 3.3� �3x0.5�0 + 6x0.373 0.38 0.�� 3.4 37.4 �52.4 C (500ft)
B64-0��3�002-800xx-5 �0 5.26 �3x0.643 + 6x0.47� 0.5� 0.�� 4.2 59.3 �52.4 C (500ft)
B64-0��30002-800xx-5 8 8.37 �3x0.8�0 + 6x0.593 0.76 0.�3 5.5 96.8 �52.4 C (500ft)
* Listed as TFFN wires.
UL 83 Underwriters Laboratories, Thermoplastic Insulated Wires and Cables.UL �063 Underwriters Laboratories, Machine Tool Wires and Cables.UL �58� Underwriters Laboratories, Reference standard for Electrical wires, Cables and Flexible Cords.
Color Black Blue Color Red Red/Yellow
xx Color Code BK BL xx Color Code RD RY
Color Brown G/Y Color Turquoise Violet
xx Color Code BR GY xx Color Code TR VL
Color Gray Green Color White Yellow
xx Color Code GR GN xx Color Code WT YL
Color Orange Pink
xx Color Code OR PK
Standards:
C : Coil
��
APPLICATION:
Widely used in new constructions. Suitable for lighting and power purposes in industrial, commercial and residential buildings. THHN/THWN wires are designed to operate at conductor temperatures of 75ºC for 600 volts service in wet and dry locations. THHN/THWN wires are also suitable for control circuits, machine tools and appliances. Nylon jacket provides mechanical ruggedness and resistance to Acids, Alkalis, Oils, Gasoline and Chemicals.
CONSTRUCTION:
Conductor
Soft drawn annealed copper conductors, solid or �9 wires combination unilay for sizes �4, �2 and �0 AWG. Size 8 AWG available in stranded only.
Insulation
Extruded Polyvinyl Chloride (PVC) compound meets all the performance requirement as per UL83. UL rated VW� conductors. PVC insulation also meets the UL758 requirements for �05ºC appliance wiring material.
Jacket
Tough, smooth, heat and light stabilized, low moisture absorption nylon conforming to UL requirements for type THHN or THWN. This jacket offers a great degree of protection to the PVC insulation from abrasion and cut through which may be encountered in pulling wire through conduits. Nylon has long been recognized as one of the toughest jacketing materials used in wire and cable manufacturing.
FEATURES:
* Meets UL “VW-�” Flame Test requirements. * Wet or dry locations, rated 90oC dry, 75oC wet. * Resistance to gas and oil exposure, rated gasoline and oil resistance II as per UL83. * Versatile - can be used as follows: THHN - 90ºC dry building wires. THWN - 75ºC wet and dry building wires. * Pulls easier - tough, smooth nylon jacket over PVC insulation. * Small diameter - more conductors per conduit.
JORDAN NEW CABLE COMPANY DOMESTIC WIRING600 Volts - THHN / THWN AWG WIRES
Cu/PVC/NYLON UL-83, UL-�58�