2
340-360 1500V Series JAM72S01 340-360/PR 1500V Percium Series 355 47.45 38.76 9.69 9.16 18.28 ELECTRICAL PARAMETERS AT NOCT Max Power (Pmax) [W] Open Circuit Voltage (Voc) [V] Max Power Voltage (Vmp) [V] Short Circuit Current (Isc) [A] Max Power Current (Imp) [A] TYPE Electrical data in this catalog do not refer to a single module and they are not part of the offer. They only serve for comparison among different module types. US_EN_20170728A NOCT Harvest the Sunshine Premium Cells, Premium Modules www.jasolar.com P r Current-Voltage Curve (JAM72S01-355/PR) Power-Voltage Curve (JAM72S01-355/PR) Current-Voltage Curve (JAM72S01-355/PR) 40℃ 55℃ 70℃ 10℃ 25℃ SPECIFICATIONS Cell Weight Dimensions Cable Cross Section Size Junction Box Connector Packaging Configuration 1960×991×40mm 72 (6×12) IP67, 3 diodes Amphenol UTX 27 Per Pallet 1500V ELECTRICAL PARAMETERS AT STC TYPE Module Efficiency [%] Power Tolerance STC Irradiance 1000W/m²,cell temperature 25, AM 1.5G 345 47.05 38.39 9.54 8.99 17.76 340 46.86 38.18 9.46 8.91 17.50 350 47.24 38.58 9.61 9.07 18.02 JAM72S01 -340/PR -0~+5W +0.060%/-0.300%/-0.390%/customized cable length available upon request -40~+8520A 5400Pa 2400Pa 45±2Type 1 Class A 1500V DC (UL) Maximum System Voltage Operating Temperature Maximum Series Fuse Maximum Static Load, Front* Maximum Static Load, Back* NOCT Fire Performance Application Class 360 47.66 38.96 9.78 9.24 18.53 360W Mono Si 72 Cells Junction Box Label Draining Holes 8 places Mounting holes 8 places Grounding holes 6 places Mounting holes 4 places for NEXTracker 4 places for NEXTracker Mono 156.75x156.75mm *For NexTracker installations static loading performances: front load measures 2400Pa while back load measures 1600Pa. MECHANICAL DIAGRAMS OPERATING CONDITIONS CHARACTERISTICS No. of cells 4mm 2 22.5kg±3% Rated Maximum Power (Pmax) [W] Open Circuit Voltage (Voc) [V] Maximum Power Voltage (Vmp) [V] Short Circuit Current (Isc) [A] Maximum Power Current (Imp) [A] (α_Isc) (β_Voc) (γ_Pmp) Irradiance 800 W/m 2 , ambient temperature 20, wind speed 1 m/s, AM 1.5G 261 43.88 35.81 7.68 7.29 250 43.28 35.25 7.48 7.09 257 43.68 35.78 7.61 7.19 254 43.52 35.51 7.54 7.14 265 44.10 36.03 7.74 7.34 12AWG(112 lb/ft ) 2 (50 lb/ft ) 2 Current (A) 0 2 4 6 8 10 0 10 20 30 40 50 1000W/m 2 800W/m 2 600W/m 2 2 400W/m 200W/m 2 Power (W) 0 50 100 150 200 250 300 400 0 10 20 30 40 50 1000W/m 2 800W/m 2 600W/m 2 400W/m 2 200W/m 2 Current (A) 0 2 4 6 8 10 0 10 20 30 40 50 Voltage (V) Voltage (V) 350 Voltage (V) JAM72S01 -345/PR JAM72S01 -350/PR JAM72S01 -355/PR JAM72S01 -360/PR JAM72S01 -340/PR JAM72S01 -345/PR JAM72S01 -350/PR JAM72S01 -355/PR JAM72S01 -360/PR

JAM6(K) 72 340-360PR 1500V F40-35 Nextracker更新版去横杆版本 · Maximum Power Voltage (Vmp) [V] 340-360 1500V Series

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

340-360 1500V Series

JAM72S01 340-360/PR 1500V Percium Series

355

47.45

38.76

9.69

9.16

18.28

ELECTRICAL PARAMETERS AT NOCT

Max Power (Pmax) [W]

Open Circuit Voltage (Voc) [V]

Max Power Voltage (Vmp) [V]

Short Circuit Current (Isc) [A]

Max Power Current (Imp) [A]

TYPE

Electrical data in this catalog do not refer to a single module and they are not part of the offer. They only serve for comparison among different module types.US_EN_20170728A

NOCT

Harvest the SunshinePremium Cells, Premium Modules

www.jasolar.com

P r

Current-Voltage Curve (JAM72S01-355/PR)

Power-Voltage Curve (JAM72S01-355/PR)

Current-Voltage Curve (JAM72S01-355/PR)

40℃

55℃

70℃

10℃

25℃

SPECIFICATIONS

Cell

Weight

Dimensions

Cable Cross Section Size

Junction Box

Connector

Packaging Configuration

1960×991×40mm

72 (6×12)

IP67, 3 diodes

Amphenol UTX

27 Per Pallet

1500V

ELECTRICAL PARAMETERS AT STC

TYPE

Module Efficiency [%]

Power Tolerance

STC Irradiance 1000W/m²,cell temperature 25℃, AM 1.5G

345

47.05

38.39

9.54

8.99

17.76

340

46.86

38.18

9.46

8.91

17.50

350

47.24

38.58

9.61

9.07

18.02

JAM72S01 -340/PR

-0~+5W

+0.060%/℃

-0.300%/℃

-0.390%/℃

customized cable length available upon request

-40℃~+85℃

20A

5400Pa2400Pa

45±2℃

Type 1

Class A

1500V DC (UL)Maximum System Voltage

Operating Temperature

Maximum Series Fuse

Maximum Static Load, Front* Maximum Static Load, Back*

NOCT

Fire Performance

Application Class

360

47.66

38.96

9.78

9.24

18.53

360W Mono Si 72 Cells

Junction Box

Label

Draining Holes8 places

Mounting holes8 places

Grounding holes6 places

Mounting holes4 places for NEXTracker

4 places for NEXTracker

Mono 156.75x156.75mm

*For NexTracker installations static loading performances: front load measures 2400Pa while back load measures 1600Pa.

MECHANICAL DIAGRAMS

OPERATING CONDITIONS

CHARACTERISTICS

No. of cells

4mm2

22.5kg±3%

Rated Maximum Power (Pmax) [W]

Open Circuit Voltage (Voc) [V]

Maximum Power Voltage (Vmp) [V]

Short Circuit Current (Isc) [A]

Maximum Power Current (Imp) [A]

(α_Isc)

(β_Voc)

(γ_Pmp)

Irradiance 800 W/m2 , ambient temperature 20℃,wind speed 1 m/s, AM 1.5G

261

43.88

35.81

7.68

7.29

250

43.28

35.25

7.48

7.09

257

43.68

35.78

7.61

7.19

254

43.52

35.51

7.54

7.14

265

44.10

36.03

7.74

7.34

(12AWG)(112 lb/ft )2

(50 lb/ft )2C

urre

nt (A

)

0

2

4

6

8

10

0 10 20 30 40 50

1000W/m2

800W/m2

600W/m2

2400W/m

200W/m2

Pow

er (W

)

0

50

100

150

200

250

300

400

0 10 20 30 40 50

1000W/m2

800W/m2

600W/m2

400W/m2

200W/m2

Cur

rent

(A)

0

2

4

6

8

10

0 10 20 30 40 50

Voltage (V)

Voltage (V)

350

Voltage (V)

JAM72S01 -345/PR

JAM72S01 -350/PR

JAM72S01 -355/PR

JAM72S01 -360/PR

JAM72S01 -340/PR

JAM72S01 -345/PR

JAM72S01 -350/PR

JAM72S01 -355/PR

JAM72S01 -360/PR

Excellent Low-lightPerformance

EQE—External quantum efficiency

Cur

rent

[A]

300 400 500 600 700 800 900 1000 1100

Wavelength (nm)

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0

PERCIUMNormal Mono

Nor

mal

ized

EQ

E

Average Mass Production Efficiency >21%Percium Cell

Cost saving estimation made by comparison between 330W and 355W modules

Benefit: Save System Costs Per Watt

More Power Per m²

Higher conversion efficiency - more power production

per unit area

Lower System Cost

Transportation costs

Installation costs

BOS costs

Higher conversion efficiency helps you to save

Benefit: 7% More Power

Percium module 355Wp VS Conventional module 330Wp

Conventional Percium

+7%

Harvest the SunshinePremium Cells, Premium Modules

Harvest the SunshinePremium Cells, Premium Modules

6% less

Installation costs

7% less

Transportation costs

4% less

BOS costs

High Reliability

Comprehensive Certificates

IEC 61215, IEC 61730, UL1703, CEC Listed, MCS and CE

ISO 9001: 2008: Quality management systems

ISO 14001: 2004: Environmental management systems

BS OHSAS 18001: 2007: Occupational health and safety management systems

Environmental policy: The first solar company in China to complete Intertek's carbon

footprint evaluation program and receive the green leaf mark verification for our products

PID-resistance tests

Certified by TÜV SÜD and ETL

Industry-leading cell technology

High quality components from best suppliers

Harsh climate environment endurance tests

Long-term reliability tests

Manufacturing inspected and certified by PI-Berlin and Solar-IF

100% in-house automatic manufacturing

Other Features

FraunhoferPIBERLIN

PI

Thresher Test

TC 600DH 3000

UV 45 kW/m2HF 30

Hot Spot 20h

Product Warranty12-year product warranty25-year linear power warranty

JA Solar Holdings Co., Ltd.

Partner Section

Additional Insurance Options

PowerGuard�

SPECIALTY INSURANCE SERVICES

SOLARSOLARI N S U R A N C E & F I N A N C E

Excellent mechanical load resistance: Certified to withstand

high wind loads (2400Pa) and heavy snow loads (5400Pa)

Positive power tolerance: 0~+5W

Modules binned by current to improve system performance

5400Pa

2400Pa

0~+5W

finger“inverted” pyramids

np-silicon

passivated layer

AR Coating

SiNx Local BSF

The mono cell technology with passivated backside

and local BSF

>21% average mass production efficiency

Relative module efficency comparison under different irradiance

Source:

Benefit:Excellent Low-light Performance

Enhanced spectral response at longer wavelength boosts low-light performance, which can produce more than 3% additional power compared with conventional module at system side.

93%

94%

95%

96%

97%

98%

99%

100%

101%

102%

100 200 300 400 500 600 700 800 900 1000 1100

Rel

ativ

e ef

ficie

ncy

(%)

Irradiance (W/M2)

Conventional Mono Conventional Poly PERCIUM Mono

Add: Building No.8, Nuode Center, Automobile

Museum East Road, Fengtai District, Beijing, China

Tel: +86 (10) 63611888 Fax:

+86 (10) 63611999

Email: [email protected] [email protected]

JA Solar Holdings Co.,Ltd is a world leading manufacturer of high-performance solar power products that convert sunlight into electricity for residential, commercial and utility-scale power generation. The company was founded in May 2005 and publicly listed on NASDAQ in February 2007. JA Solar has been the world's leading cell producer since 2010, and has firmly established itself as a tier 1 module supplier since 2012. Capitalizing on our strength in solar cell technology, we are committed to provide modules with unparalleled conversion efficiency, yield efficiency, and reliability to enable you to maximize your returns on PV projects. With its leading industry experience, continuous effort on R&D, customer-oriented service and solid financial status, JA Solar is your best choice of long-term trustworthy partner.