Contents
• Status of Central Barrel– SPD– SDD– SSD– Thermal shields
• Status of RB24 & RB26 side– Support cones– Cables, cooling tubes, and ducts– Patch panels, cable trays, and Shoe boxes– ITSAMS system
• Material Definitions• Service code
– Step manager– Module decoding routines– Simplified geometry for fast display
http://www.to.infn.it/~tosello/EngMeet/ITSdraw/http://www.to.infn.it/~tosello/EngMeet/EngMeet.html
• Sensitive volume must have thin direction in Direction• Z direction || to ALICE Global Z direction• Must follow ALICE naming and numbering conventions• Sensitive volume name ITS1, ITS2, ITS3, ITS4, ITS5, & ITS6.• Note, layer, Ladder, and Detector numbering schema not
allowed (does not follow ALICE standards).• Follow hardware conventions when ever possible
– Avoid inversion– Use measured positions when known
• Make Detectors repositionable independent of other non-sensitive objects
• Make volume/object names meaningful• Note, location of non-sensitive material known to about 1mm
absolute only.
Central Barrel Requirements/Rules
€
) y
SPD Central Barrel
• SPD Carbon Fiber Sector• Half staves
– Ladder• Grounding shield• Pixel detector• bump bonds• Read out chip
– Kapton/Al cable– Stave end chips– Solder joints
• Mounting clip • Cooling tubes • Thermal Shield
http://alice.pd.infn.it/latestdr/index.html
SDD Central Barrel
• Ladder • Detector • Sensitive volume ?• Front end
– Capacitors– Chips ?
• Kapton/AL cables • Thermal Shield • Cooling tubes • Ladder end electronics ?• Ladder end cables & tubes ?• Ladder Support Ring ?
http://www.to.infn.it/~giraudo/disegni.html
2 SDD ladders :
SSD Central Barrel
• Ladder • Detector
– Sensitive volume ?
• Front end – Capacitor ?– Chips ?
• Cooling tube • Kapton/Al cables • Ladder end electronics ?• Ladder Support ring • Thermal shield • Al-Mylar outer shield
http://www.to.infn.it/~tosello/EngMeet/ITSdraw/SSD/SSD_drawings.html
SPD Services• Support Cone (copy needed)
• Kapton/Al Cables – Cable joints
• Cooling tubes • Cooling manifold
– Cu block– Soldered Cu tubes
• Patch Panels– Connectors – Cables
• Cable Trays (Guess)– Cables
• Shoe Boxes – Connectors– Cables– Electronics
• Support Cone• Kapton/Al Cables • Cooling tube loops • Patch Panels
– Connectors – Cables
RB24 open Side RB26 Side Muon• Cable Trays
– Cables • Shoe Boxes
– Connectors– Cables– Electronics
SDD Services
• Support Cone • Kapton/Al Cables • Cooling Tubes • Patch Panels
– Connectors – Cables
• Cable Trays (Guess)– Cables
• Shoe Boxes – Connectors– Cables– Electronics
• Support Cone • Kapton/Al Cables • Cooling Tubes • Patch Panels
– Connectors – Cables
RB24 Open side RB26 Muon side
http://alice-its.web.cern.ch/Alice-ITS/
• Cable Trays – Cables
• Shoe boxes – Connectors– Cables– Electronics
SSD Services
• Support Cone (old design) • Kapton/Al Cables • Cooling Tubes • Patch Panels
– Connectors – Cables
• Cable Trays (Guess)– Cables
• Shoe Boxes – Connectors– Cables– Electronics
• Support Cone (old design) • Kapton/Al Cables • Cooling Tubes • Patch Panels
– Connectors – Cables
RB24 Open side RB26 Muon side
http://alice-its.web.cern.ch/Alice-ITS/
• Cable Trays – Cables
• Shoe boxes – Connectors– Cables– Electronics
ITSAMS/Other
• SSD cone wings • Mirrors • Patch panel • Cable Tray • Shoe Box • TPC mounted Camera • ITS-TPC Mounting Brackets • FMD/T0 RB24/RB25
– Patch Panel • Connectors • Cables
– Cable Trays • Cables
– Shoe Box • Connectors • Cables • Electronics
http://www.physics.ohio-state.edu/HIRG/ITSAMS/
Material Definitions
• SPD Central– Dummy only
• SDD Central– Mostly done
• SSD Central– Partly done
• Services– Dummy only
StepManager (SDD only), Detector decoding
SDD
http://www.to.infn.it/~tosello/EngMeet/ITSmat/SDD/0_SDDmat.html