8
NEW testo 184 data logger: Temperature monitoring and quality data documentation during the transport of foods and pharmaceutical goods. It’s Simple. Protect the integrity of your products and your brand during cold chain transportation.

It’s . · PDF file · 2017-07-18age conditions have not been exceeded. To obtain detailed ... • The comprehensive alarm management allows the setting of ... 0981 3984/msp/I/11.2013

  • Upload
    ledien

  • View
    214

  • Download
    2

Embed Size (px)

Citation preview

NEWtesto184datalogger:Temperaturemonitoringandqualitydatadocumentationduringthetransportoffoodsandpharmaceuticalgoods.

It’s Simple.Protecttheintegrityofyourproductsandyourbrandduringcold chain transportation.

2

testo 184

Optimum temperatures for sensitive goods.Shippingtemperatureandenvironmentally-sensitiveproductsrequireareliablelogger

thatprovidesaccuratedataeachandeverytime.Monitorthetransportofcoldchainproducts

with thetesto184dataloggers.

DeliveryTransportStorageProduction

Withthetesto184dataloggers,youcanmonitoreverystepofthe

coldchain.Theloggerstravelduringfreightandinloadingrooms,

monitoringtemperaturesthroughoutthetransportationofsensitive

goodsontherail,intheair,orontheroad.

Attheirdestination,youcanquicklyconfirmthattheproperstor-

ageconditionshavenotbeenexceeded.Toobtaindetailed

information,simplyconnecttheloggertoaPC,andaPDFreport

isimmediatelygeneratedwithallrelevantdata.

Forevenmoreefficiencyandconvenience,allrequiredfilesand

informationarestoreddirectlyandsecurely,including:

configurationfile,calibrationcertificate,instructionmanualand

PDFreportofyourrecordeddata.

3

Temperature monitoring for

pharmaceutical logistics

AvisitfromaGMP(GoodManufacturingPractice)inspectorcan

beaseriousissueforyourcompanyifyoudon’thavethecorrect

equipment.Neitherinsufficientrefrigeration

duringthetransportofthelastdelivery,northeincomplete

documentationofthetemperaturevaluesinyourpaperworkwill

passinspection.Intheworstcase,thereisathreatofproduct

recall,hugefinancialdeficitsandthelossofyourgoodreputation

inthepharmaceuticalindustry.

Or,avisitfromaGMPinspectorcanbeabreeze.Withthetesto

184dataloggers,all(bio-)pharmaceuticalscanbeprotectedfrom

unnoticedgapsinthecoldchain.Theentiredistributionprocess

ismonitoredanddocumentedsimply,securelyandcompliantly

withallcommonstandards,guidelinesandregulations:

•ThetemperaturedataloggersT1,T2,T3andT4aredelivered

withacalibrationcertificatetraceableaccordingtoISO17025,

whichisstoredasaPDFdirectlyinthelogger.

•ThankstotheuseofthevalidatableComSoftCFRsoftware,21

CFRPart11-compliantapplicationswithalltesto184data

loggersispossible.

•Forthepurposesoftheanalysisofstabilitydata,thelogger

supportsyouwithanautomaticMKT-valuecalculation,andthe

optionofsettingMKTalarms.

•Thecomprehensivealarmmanagementallowsthesettingof

multiplealarmlimits.Itisalsopossibletosetcumulativealarms,

e.g.whenthetemperaturemaynotexceedthelimitvalueof

30°Cforlongerthan30minutes.

•Theextremelyintuitiveoperationandtheeasyidentificationof

alarmsleadtoalowtrainingrequirementforyourstaff.

Temperature monitoring for

food logistics

Theadherencetopre-definedtemperaturevaluesisofparamount

significanceinthetransportationoffood.Thisistheonlyway

legalhygienestandardscanbefulfilledandthequality,safetyand

preservationoffoodgoodsguaranteed.Theprecisemonitoringof

thecomplexprocessesandproceduresisdefinedintheHACCP

guidelines(HazardAnalysisCriticalControlPoints),whose

purposeisthepreventionofhealthrisksinthefoodsector.

Thetesto184dataloggersarecertifiedbyHACCPInternational,

andcriticalforthemonitoringoffoodproductstorageintransport

fromthefarmerallthewaytothesupermarketcustomer.The

documentationofthequalitydataisextremelyeasythankstothe

convenientreadoutfunctionbyanautomaticallygeneratedPDF

report.Temperature-sensitivefoodsarrivesafelyandyourbrand

staysprotected.

4

testo 184

Plug and Play.Alltheadvantagesofthetesto184dataloggersataglance.

Clear indication of alarmsAglanceatthedisplayortheLEDsisenoughtoknowwhetherlimitvalueshavebeenexceededduringtransport.

Convenient readout APDFreportwiththetransportdataiscreatedimmediatelyuponconnectionofthetesto184dataloggertotheUSBportofacomputer.Thisissuitableforlong-termarchivingaccordingtoPDF/Astandard.

Easy operationtesto184isintuitivelyoperated,andcanbeusedwithoutspecialtrainingorpreviousknowledge:The"Start"buttonbeginsdatarecording."Stop"endsit.

Mobile readout/printout on siteAlltesto184dataloggerscanbereadouton-sitewithanNFC-capableAndroid smartphone.DatatransferfromthedataloggertoacompatibleTestoprinteralsofunctionswirelesslyviaNFC.

Simple configuration - no software requiredAsimple,easytofollow,configurationfileis onboardevery184sothatnosoftwareis neededfordownloadsorset-up.Evendifferentlanguagescanbeselectedforshipperand receiver.

IT-safeThetesto184dataloggersworksecurelywithoutsoftwareinstallationordownload,sothatITproblemsaretriggeredneitherbythefirewallnoravirusscanner.

Actualsize

CFR readyISO9001:2008

CERTIFIED

5

ISO, GxP, CFR, HACCP and EN 12830.Themostimportantstandardsforthetransportofpharmaceuticalsandfoods.

GxP-guidelinesInaGxP-regulatedenvironment,especiallyhighdemandsareplacedonqualitymanagement.NotonlyGMPorGLP,butalsoGDP(GoodDistributionPractice)guidelinesplayanincreasinglyimportantpart.Sincethedistributionofpharmaceuticaland medicinalproductsisnothingmorethanmobilestorage,thesamerulesapplyhereasinproduction,withregardtomonitoringandqualityassurance.Withthehelpofthetesto184datalogger,GxP-compliantworkisnoproblemforyou.

ISO 9001:2008ISO9001:2008isthemostsignificantinternationalnormforqualitymanagementsystems,andguaranteestheframeworkconditionsforahighlevelofquality-capabilityforproductsandprocesses.However,inconnectionwiththis,itisalso indispensabletobefullyinformedoftheprofessionalquality assuranceofthethesuppliersinvolvedintheprocess.TestoAG,asanISO9001:2008-certifiedcompany,fullycomplieswiththeserequirements,andensurestheadherencetothenormsthroughinternalauditsaswellasaccreditedexternalaudits.

FDA 21 CFR Part 11TheFDAregulation21CFRPart11,onwhich,amongothers,Appendix11oftheEU-GMPisbased,makesstipulationsonelectronicallystoreddocumentsinwhichelectronicsignaturesaremade.Theuseofthetesto184dataloggers(incombinationwiththevalidatableComSoftCFRsoftware)provides:Limitationof accesstoauthorizedpersons,AuditTrailswithtimestamp,aswellaselectronicsignatures,allowinga21CFRPart11- compliantuseofthedataloggers.

HACCP International certificationHACCPInternationalisaleadingorganizationinthefieldoffoodsafety,andtestsproductsfortheirsuitabilityforfood environmentprocessesaccordingtotheInternationalHACCPguidelines.Thetesto184dataloggersarecertifiedas“food-safe”byHACCPInternational,andthuscanberecommendedwithoutrestrictionforuseintheHACCPenvironment.

EN 12830ThestandardEN12830establishesthetechnicalandfunctionalpropertiesoftemperatureregistrationinstrumentsfortransport,storageanddistributionplantsforchilled,frozenordeep-frozenfoodsandice-cream.Thetransportloggerstesto184T1,T2,T3andT4fulfiltheserequirements,andhavebeencorrespondinglycertifiedbyTÜV.

6

testo 184

Safe monitoring of temperature, humidity and shock.

Overviewofthetesto 184dataloggers.

ü

üü

ü

ü

üü

ü

üü

üü

ü

ü

üü

üü

ü

Order No. 0572 1841

Measurementparameters Temperature

Exchangeablebattery

Operatingtime

Batterylife

Measuringrange

Resolution

Measurementrate

Storagetemperature

Memory

Accuracy

Temperature

Protectionclass

Alarmidentification

ReadoutviaNFC

AutomaticPDFgeneration

EN12830-certified

HACCP-certified

CompatiblewithtestoComSoftCFR21Part11

TemperaturecalibrationcertificatetraceableaccordingtoISO17025

Order No. 0572 1842 Order No. 0572 1843

Temperature

90days

-31°to158°F(-35°to70°C)

0.18°F(0.1°C)

Unlimited150days

500days(at+77°Fand15min.meas.cycle)

-31°to158°F(-35°to70°C)-31°to158°F(-35°to70°C)

0.18°F(0.1°C) 0.18°F(0.1°C)

±0.9°F(±0.5°C)±0.9°F(±0.5°C)±0.9°F(±0.5°C)

1 min to 24 h

-67°to158°F(-55°to70°C)

1 min to 24 h

-67°to158°F(-55°to70°C)

1 min to 24 h

-67°to158°F(-55°to70°C)

16,000readings

IP67

byLEDs

40,000readings

IP67

byLEDsanddisplay

40,000readings

IP67

byLEDsanddisplay

testo 184 T1 testo 184 T2 testo 184 T3

7

ü ü ü

ü

üü

üü

ü

ü

üü

üü

üü

ü

Temperature Temperature/humidity Temperature/humidity/shock

Order No. 0572 1844 Order No. 0572 1845 Order No. 0572 1846

Unlimited Unlimited Unlimited

100days(at-112°F(-80°C)and15min.meas.cycle)

500days(at77°F(25°C)and15min.meas.cycle)

120days(at+77°F(25°C)and15min.meas.cycle)

-112°to158°F(-80°to70°C) -4°to+158°F(-20°to70°C)/0to100%RH -4°to+158°F(-20°to70°C)/0to100%RH/0to10g

0.18°F(0.1°C) 0.18°F(0.1°C)/0.1%RH 0.18°F(0.1°C)/0.1%RH/0.1g

±1.4°F(±0.8°C)(-112°to-31.2°F)(-80°to-35.1°C)

±0.9°F(±0.5°C)(-31°to158°F)(-35°to70°C)

±0.9°F(±0.5°C)(32to+158°F)(0°to70°C)±1.4°F(±0.8°C)(-4to32°F)(-20°to0°C)±1.8%RH+3%ofm.v.at77°F(25°C)

(5to80%RH)±0.03%RH/K(0to140°F)(0°to60°C)

±0.9°F(±0.5°C)(32to158°F)(0°to70°C)±1.4°F(±0.8°C)(-4to32°F)(-20°to0°C)±1.8%RH+3%ofm.v.at77°F(25°C)

(5to80%RH)±0.03%RH/K(0to140°F)(0°to60°C)

±0.1g+5%ofm.v.

1 min to 24 h

-112°to158°F(-80°to70°C)

1 min to 24 h

-67°to158°F(-55°to70°C)

1 min to 24 h

-67°to158°F(-55°to70°C)

40,000readings

IP67

byLEDs

64,000readings

IP30

byLEDsanddisplay

64,000readings(temperatureandhumidity) +1,000readings(shock)

IP30

byLEDsanddisplay

– –

testo 184 T4 testo 184 H1 testo 184 G1

Order Information: 1-800-227-0729 | www.testo.com

testo 184

0981

398

4/m

sp/I

/11.

2013

Sub

ject

to

chan

ge w

ithou

t no

tice.

testo 184 T3• Measurementparameter:Temperature• Operatingtime:unlimited• Availableinpacksof:1,10and50

testo 184 T4• Measurementparameter:Temperature• Operatingtime:unlimited• Availableinpacksof:1and10

testo 184 T1• Measurementparameter:Temperature• Operatingtime:90days• Availableinpacksof:1,10and50

testo 184 T2• Measurementparameter:Temperature• Operatingtime:150days• Availableinpacksof:1,10and50

testo 184 G1• Measurementparameters:Temperature, humidityandshock• Operatingtime:unlimited• Availableinpacksof:1

testo 184 H1• Measurementparameters:Temperature andhumidity• Operatingtime:unlimited• Availableinpacksof:1,10and50

Ordering information testo 184 data logger.

WallholderPartno.01921963

Partno.05721845

Wallholderincluded

Partno.05721846

WallholderPartno.01921963

WallholderPartno.01921963

Partno.05721843 Partno.05721844

WallholderPartno.01921963

Partno.05721842Partno.05721841