ItemViscometer
Magnetic stirrer withhot plate
Flash and fire pointApparatus ./
Distillationapparatus !.
---- ----;Quantity ~
lOne
SpecificationsREDWOOD VISCOMETER- For viscosity test of petroleum products.
1
- Heating: Electrical type \\ ith Energy regulator controlsuitable to operdte on S:ngle Phase 220 I 230 volts A.C.supply
- Thermometers. (-90°C to 370°C)- Redwood Flow Range: above 2000 sec.- Display 3.S Digit LEDInstrument should have:- Simultan'eous display of the measured values in pH mV
I - Auto-Buffer Recogn~tionI - Self-Diagnostic with Message Codes Disrla)
- Automatic temperature compensation- Large LCD Display
- Range pH 0 to 14.0,- mV 0 to ± 1999- Resolution pH 0.01. mV : I- Accuracy ph ±0.01 pi L mV ±l mV- Temperature Compensation
a) Auto: 0 t6 100°C.b) Manual : 0 to 100°C
- Power: 9Y Adapter 220V/SOHz
II
Ii
i------IMaximum Speed RPM 2000Total 10 Litre capacityStirring Capacity Ltrs 5 lOneHeating Capacity Watts SOOW I
Power: Single Phase 220 volts A.C. supply. __ ~~ __ .1- ----------1
- For determining the flash point offuel oils and lubricating ioil- Should have oil cup cover assembly fitted \\ ith \ti",crthermometer socket water bath stand electric heme:controlled by Energy Regulator- Single Phase 2~OV. SO Hz. Single Phase, AC
-Metal Type (Table Model)-Capacity: 4 litre-Load: 4.0 K W-All contact parts in stainless steel- Double walled inside chamber of Stainless Steel.- Digitally controlled from SO°C to 300°e, + - 1°C.- To operate on 220/230 Volts. A.C Supply- Air Circulation Fan- Digital Temp. Controller cum Indicator- Mechanical Timer __ _ _ _ 1__~I-Power:- 220V/50Hz I! One-Max. Power: 190W-Max Vacuum: -650mm/llg I-Motor rotation: 1450 rpm if--Power: j-4 HP --- -----~_1-For determination of combustion heat or calorific values of
I Coal. solid and liquid fuels. tOneInstruments should have
1
- Digital Thermometer I
, - Bomb tiring unit with illuminato~_ vibrator and J2.uzz~ __ -L ~_~
,,One
r---------------_~~-r~-~-~-:--~---;-;-t:-~~--~r------·------- -----i I - Full feature Digital Controller & Safety device
- Complete outer body and inner jacket in stainless steel- Workable on Single Phase 220 I 230 volts A.C. supply-Max. Speed RPM 17000-Max. RCF x g 15650-Max. Tube Size ml 50-Max. Capacity ml 200- Connected Load kva 0.18- 8 tubes x 15 ml-Capacity; 20 liters- Operating Voltage: 230 V. 50 Hz A.C- Power O/P : 500 Watts- Operating Frequency: 20 + 31 37 + 3 Khz.- Tank, Outer body. Basket and Lid Construction: S.S- Digital Timer & Temperature Controller
Electronic Balance(4 Digit) .J
Electronic Balance(2 Digit)
-4 Digit '. One-Response Time (average) 3 seconds I-Tare Range FULL to Capacity i-Selectable Application Programs Mass unit conversion by I
toggling, tare memory, net total. weighing in percent,counting, averaging
-Display Update 0.1 - 0.4 seconds-Display LCD-Allowable Ambient Operating Temperature 5° C to 40 ° C85% RH or less
- Sensitivity Drift :(10° - 30°C/50°F-86°F) ± 2 ppm 1°C-AC Power Source- With Stainless steel weighing pan-2 Digits- Response Ti me (average) 3 seconds- Tare Range FULL to Capacity- Selectable Application Programs Mass unit conversion by
toggling, tare memory, net total. weighing in percent,counting, averaging
- Display Update 0.1 - 0.4 seconds-Display LCD-Allowable Ambient Operating Temperature 5° C to 40 ° C I85% RH or less
- Sensitivity Drift (10° - 30°C/50°F-86°F) ± 2 ppm 1°C-AC Power Source- With Stainless steel weighing pan __ __- Emulsion Type- 1 grinding station- Grindingjars with volumes from 1 Itr- 2 Itrs- 5 itrs &
10 Itrs.- Stainless steel jars- Should be suitable for long-term trials and continuous use- Should be able to handle different Feed material: soft.hard, brittle, fibrous - dry or wetSize reduction principle; impact. frictionMaterial feed size-: < 10 mmFinal fineness-: < I0 ~m. for colloidal grinding '-. I ~m-Material of grinding tools: hardened steel, stainless steel
i!lOneI
I
]4 I Compressor - Reciprocating compressorlone
I- Two stage
I
I- Displacement: 30-40 m3/h ,-Working pressure: 12-15 kg/cm2- Compressor speed: 900-1000 rpm- Power: 220/230 volts A.c. supply, 50 hz- Starter: DOL
15 Micro pipette set Digital variable volume micropipette IA sel of7- Autoclavable [lower part]. pipettes
I
- Two-button operation,, - Chemical resistant,- User-friendly Calibration technique.
I I- Should have stream of lined tip ejector and having I
adjustment of volume b:- turning the plunger \\ ith t\\O step Ioperation.
IVoI.Range(IlI): 0.1-1.5: 0.5-10: 2-20: 10-100:20-200:100-1000 ; 500-5000
16 Thickness Application: For Measuring thickness of steel, cast iron,measurement system aluminum, red copper, brass, zinc, quartz glass, polythene, One
PVC and gray cast iron ,.-Measurement Range: 101lm----200mm I
0.06----8inchI-Sensor Type: Ultrasonic
-Should include Calibration BlockI-Resolution: 0.1 mm
-Accuracy :±(O.5%N+0 .2)17 UV lamp -UV Source with dual wavelength of 365nTrl and 254nm One
-6W UV Tubes, Transparent \\indO\\ with push to ON iSwitch
~-~ ~ ------ ------r-~----18 Digital multimeter ,
(for I-V - 6.5 digit resolution Onecharacteristics) -Basic V dc accuracy of up to 0.0024 %
- Dual display-100 IlA to lOA current range, with up to 100 pA
resolution-Ohms ranges from lOW to 1 GW with up to 1011 Wresolution-2 x 4 ohms 4-wire measurement technique. -Measurement of frequency, period, capacitance andtemperature-USB memory drive port-Graphical display-Operating. Temperature: o °C to 55°C
19 Water bath Refrigerated/Heating CirculatorITemp. Range: -20 to + 150aC One
Temp. Stability: ::t. 0.005°CController: PIDReadout: LED:
I
IReadout selectability: "c, of, user detined
IReadout accuracy: ± 0.5°C;Reservoir capacity: 6 Itrs.
ICooling capacit) @:+20"C 200W. O°C 140W, -IOcC 100WPressure flow rate: 2-speed, 9 or 15 Itrs/min
IShipping weight: 68 Ibs/31 kg ISupply Voltage: 240V/50Hz AC I
---~~--~ .-
I CCD camera
I
CCD Colour camera ! OneResolution: 1624 x 1234Frame per second: up to 13Digital interface: IEEE 1394bImage device:Type 1/I.8(diad.9mm):progressive scanPicture size: 1624(H) x 1234(V)Cell Size:4.4j..lm x4.4j..lmResolution depth:8bit/14bit( 16 bit in high SNR mode)Les mount: C-Mount/Optional :CS- MountGain control: Manual:0 ... 24db,auto gainShutter speed:48~l s .... 67s, auto shutterPower requirements: DC 8V-36V;<3.5W(fiber<4W)@12VOperating temperature: -10 +16° Celsius
I.Diode La~er(Green Laser)Wavelenth-532nm, Power-5mw
----- --~-2. Diode Laser mount: Diameter:25mm
4. Spatial filter: 10mm linear movement, 3mm XYadj ustments
5. Pin Hole with mount: Aperture diameter:20micrometer
6. Rails and carriers : Rail-500mm Length Carriers-75mm Length :
Type: Shore A Standard: ASTM o-r-o-ne2240 Application: For soft rubber. elastomers, Inatural rubber, soft PVe. leather, etc.
Accuracy: ±0.1 % Brix±0.0002 Rl One
Type: Digital Laboratory RefractometersResolution: 0.1% Brix 0.0001 RITemp compensation: 32 to 104°F (0 to 40°C)Display 3-digit LCDRange: 45.0 to 95.0% Brix
1.4098 to 1.5318 RIResponse time: 3 secondsSample volume: 0.4 mLDimensions: 7 in W x 2.5 in H x 4 in 0
,- --Inverted tissue culture Trinocular microscope for
brightfield and phase contrast applications (30° inclined, Oneinterpupillary 48mm~75mm) having 6v30w halogen lightilluminator, quintuple revolving nosepiece, coaxial coarse(stroke: 37.7mm per rotation) & fine (stroke: 0.2mm perrotation) adjustment. plain stage (160x250mm) with glassinsert, auxiliary stage 70x 180mm, (stage adaptable for96well plate,T -flask and counting chamber)(Condenser (NA 0.3) LWD 72mm (without condenser150mm),Long working distance Plan Infinity Brightfield Objectives,4x/O.1 (W.D 18mm) & 40x/0.6 (W.D 2.6mm - Cover Glass1.2mm)Phase Contrast Objectives 10x/O.25 (W.D IOmm) &
20x/OA (W.D 5.1mm) with phase annulus plate (1Ox-20x,40x) & High eyepoint.Extra wide field eyepiece EWIOx (F.N.22) standard setcomplete.Required features:Long Working Distance Plan Infinity Optics.Pre-Centered Phase Annulus Trinocular Port In StandardUnit
25 Chemicals1 Acetone 2.5 lit
2 Hydrochloric acid 500 ml x 3
3 Sulfuric acid 500 ml x 3
4 Nitric acid 500 ml x 2
5 Ammonia 500 ml,
6 Cerium Nitrate 100 g
7 Titanium IsoPropoxide 250 ml
8 Ethanol 2.5 lit
9 Methanol 2.5 lit
10 Silver Nitrate 50 g
11 Aluminium oxide nanoparticles 500 g
12 Titanium dioxide nanoparticle 500 g
13 Copper oxide nanoparticle 100 g
14 Toluene 500 ml
15 Potassium dichromate 500 g
16 Sodium Hydroxide 500 g
17. Chloroauric acid (SRL) I gX5
18 Trisodium citrate 500 g
19 Sodium borohydride 100 g
20 Polyethylene glycol 250 rill
21 Tetra Octyl Ammonium Bromide 100 g
22 Polyvinyl Pyrrolidinone 500 g
23 Ascorbic acid 100 g
24 N-cetyl-N-N-N-trimethyl ammonium bromide (Sd fine 100 gX2
25 Acetic acid 100 g
26 Hydrogen peroxide (30%) 500 ml
27 Isopropanol 5.00 ml
28 Aqueous ammonia 500 ml x 2
29 Cerium acetate 100 g
30 Cerium chloride 100 g
31 Potassium hydroxide 500 g
32 4-(2-Hydroxyethyl)piperazine-l-ethanesulfonic acid 500 g
33 Zinc acetate 500 g
34 Zinc nitrate 500 g
35 Potassium Bromide (Spectroscopic grade) 100 g
36 Chloroform 500mlx2
37 Manganese Acetate 500 g
38 Europium Acetate 19
39 Cerium(fIl) acetate hydrate 10 g00 OOO/A tr"f't> rY\t>t,,!c h"c;c
,
40 Cerium Nitrate Hexahydrate 25g
41 Copper(lI)Acetate hydrate 25 g99.99% trace metals basis
42 Acetone 51itres
43 Isoproponol or Isopropyl Alcohol 5 liters
44 Ammonium Hydroxide 5 liters
45 Glacial Acetic Acid 5 liters
46 Isooctane 2 liters
47 2-butanol 2 liters
Consumables
I. Test Tube Holder 10 nos.2. Flask Stand Flask Stand for round bottom flasks 2 packs
<1> 160 mm 12 nos..3. Wash Bottle 500ml I pack of 6 no~4. Test Tubes5. Test tube brush Superior thick 10nos6. Mortor and pestle 90mm OD porcelain 100 ml 2 nos7: Test Tube stand Aluminium-12H-19mm-SHIV 5 nos8. Thermometer Mercury 250°C-indian 3 nos9. FiIter paper Grade I - 90 mm 2 pack10. Measuring Cylinder 500ml 5nos.11. Measuring Cylinder 250ml 5nos.12. Measuring Cylinder 100mi 5nos.13. Measuring Cylinder 50ml 5nos.14. Measuring Cylinder 10mi 5nos.-_.- --------15. Measuring Cylinder 5m! 5nos.16. Purple nitrile 1pack of 100
gloves9.5" length piece.
17. Desiccators Vacuum <D 150mm 2 packs18. Cross spin magnetic 25x25mm I pack
stirrer19. Mask I pack20. Round Bottom Flask 5nos
500ml21. Round Bottom Flask 5nos
250 ml22. Conical Flask 500ml 5nos.23. Conical Flask 250ml 5nos.24. Conical Flask 100mi 5nos.25. Beaker Flat Bottom 5nos.
500ml26. Beaker Flat Bottom 5nos .
250ml .27. Beaker Flat Bottom 5nos.
100mi28. Heating Mantle Made of MS fitted with knitted glass fabric, Inos.
with maximum surface temperature 450°C,built in energy regulator for operation on power 240 VCapacity: 1000miWatts: 300W
29. Beaker Flat Bottom 50ml 5nos.30. Vortex Mixer Vortex shaker with speed control ,spare cup attachment, I nos.
Spare one hand attachment, Spare one hand insert, sparemicro tube insert
31. Specific gravity bottle Specific gravity bottle with capillary bore stopper 5Capacity: 50m IJoint 10/15
32. Burette Single Bore Screwcock 2Capacity: 100ml ; Sub division :0.2ml ;Tol :+/-0.1 ml
33. Burette C Single Bore Screwcock 2Capacity: 50ml; Sub division :0.1 ml; Tol :+/-0.05ml
34. Separating funnel Conical with screw cock; Capacity:250ml 235. Culture tubes Capacity :30ml 100nos
Flat bottom with screw cap mand runner liner36. Distillation Assembly R.B flask 2000ml Inos.
Splash head; Double surface condenser200mm,receiver adaptor
37. Vacuum Distillation R.B flask 3000ml, Inosassembly Multiple adaptor two necks,
Still head,Jacketed coil condenser 150mm,Reciver adaptorbent with socket connection, R.B flask 250ml, Vacuumrelease stopcock, Thermometer with P.T.F.E cone.Seperating funnel 250ml, StopperSplash headDouble surface condenser200mm,receiver adaptor
38. Variable volume Capacity:-0.51l1 to 2111 Inos.pipette
39. Glass Funnel 5nos.40 Indicator tape for 5 rolls
steam autoclave41 Round Magnetic 5 nos
stirring bar with pivot