Upload
carthic1979
View
203
Download
20
Embed Size (px)
DESCRIPTION
Transducer
Citation preview
ISTAT I300High Accuracy AnalogueTransducers
Improving competitiveness and performance iskey to any business. New solutions must bedeveloped to optimise the assets, benefit from thelatest technology capabilities and adapt to therapidly changing environment.T&D offers complete solutions for the entireenergy chain, from the primary equipment up tothe market management software.
The ISTAT I300 range of analogue transducers isdesigned to meet the world market requirementsof high accuracy and reliability with a stableoutput. Available in two compact case sizes of 55mm and150mm wide, the transducers are supplied tomeet the customers precise needs.
APPLICATIONS
Applications can be found in substations of electrical utilities and industry, forinterfacing with SCADA (Supervisory Control and Data Acquisition), buildingmanagement systems, process control equipment and switchboardinstrumentation.
ISTAT I300 analogue transducers provide local and remote indication for precisionelectrical measurement and control when used with instruments, data loggersand SCADA systems.
WHY ISTAT I300 ANALOGUE TRANSDUCERS?
ISTAT I300 transducers have been designed to provide highly accurate andreliable measurements for integration into control systems. The transducerdesign was based on research into the market needs on an international andindustrial scale.
Customer Benefits
• Comprehensive set of measurements
• Proven reliabilty gained from over 30 years of manufacturing knowledge
• High accuracy and stability
AREVA T&D
MEASUREMENTS
2>3
FEATURES
> 0.2% full scale accuracy for current and voltagetransducers
> 0.2% of reading accuracy for watt and var transducers(based on 0.19% of reading + 0.01% FSD)
> 4KV isolation withstand
> 3 x continuous current overload rating
> Integral dc auxiliary supply option
> DIN rail mounting
> High packing density
> Full range of ac and dc measurements
> High stability
DC MODEL RANGE
AC MODEL RANGE
DC/DC CONVERTER RANGE
ISTAT I300: Used by Industrial or Utility engineers,
at all voltage levels
BENEFITS
> Significant gains in overall system accuracy can resultfrom improvements in source measurement
> Compliance with international standards ensurestransducers can be used world wide
> Long life expectancy and very reliable operation inmost climates
> Quick and simple means of transducer selection
> Three voltage or current transducers can be housed ina single 150mm package
> Can be integrated into modern control schemesutilising analogue technology
> Gives accurate measurements of parameters criticalfor optimum plant use.
> Minimal maintenance costs as readjustment is notrequired
ISTAT I300Features and benefits
Model Application Case
3CA Mean sensing Current 55mm3CC Triple Mean sensing 150mm
Current3CD True RMS Current 55mm3CF Triple True RMS Current 150mm3FA to 3FD 0.1% Frequency 55mm3FE to 3FG 0.01% Frequency 150mm3K Watt hour 150mm3P Phase Angle range 150mm3R Vars range 150mm3VA Mean sensing Voltage 55mm3VC Triple Mean sensing Voltage 150mm3VD True RMS Voltage 55mm3VF Triple True RMS Voltage 150mm3VL Linear Inverse Voltage 55mm3VX Suppressed Zero Voltage 55mm3W Watts range 150mm
Model Application Case
3DA Tap Position Indicator 150mm3DB Voltage 150mm3DC Current 150mm3DD Summation 150mm3DH Thermocouple 150mm3DL 3 wire Resistance 150mm3DJ Thermocouple with CJC 150mm
Model Application Case
3BA 24V 55mm3BB 32V 55mm3BC 48V 55mm3BD 110V 55mm3BE 125V 55mm3BG 220/48V (use with 3BC) 55mm
ISTAT I300: comprehensive ac measurement range
• Technical specification• Current nominal input 1 or 5A In• Current range of use 0 to 200% In• Current burden 1.0VA • Current overload 3 x In continuous
25 x In for 3s50 x In for 1s
• Voltage input range 63.5 to 440Vn• Voltage range of use 0 to 150% Vn• Voltage burden 0.1VA • Voltage overload 1.5 x Vn continuous
2 x Vn for 10s• Frequency range 45/55 or 55/65Hz
• Acuracy of the analogue output• Nominal accuracy 0.2%• Current reference range 20 to 200% In • Voltage reference range 25 to 150% Vn
> Frequency
The 3F frequency transducer can be supplied withan accuracy of either 0.1% or 0.01%. It can besupplied with either an ac or dc auxiliary powersupply. These transducers require a fullspecification before manufacture can take place,these settings cannot be changed by the user.
0.1% 0.01%
45 … 55Hz 3FA N/a55 … 65Hz 3FB N/a48 … 52Hz 3FC 3FE58 … 62Hz 3FD 3FF47 … 53Hz N/a 3FG
• Technical specification• Voltage input range 63.5 to 440V, Vn• Voltage range of use 0 to 120% V, Vn• Voltage burden 1.5VA (0.1%),
0.1VA (0.01%)
• Acuracy of the analogue output• Nominal accuracy 0.1 or 0.01%• Voltage reference range 80 to 120% Vn
for 0.1% and 20 to 120% Vn for 0.01% models
> Watt hour with pulsed and analogue output
These transducers can be supplied with either an acor dc auxiliary power supply with the exception ofthe 3KF which can also have the option of using the3B Dc/Dc converter.. These transducers require afull specification before manufacture can take place,these settings cannot be changed by the user.
Connection Wh
single phase 3KA3 phase, 3 wire balanced, 1El 3KB3 phase, 4 wire balanced, 1El 3KC3 phase, 3 wire unbalanced, 2 El 3KD3 phase, 4 wire unbalanced, 2.5 El 3KE3 phase, 4 wire unbalanced, 3 El 3KF
RANGE
> AC Mean Sensing Current and Voltage
The 3CA current and 3VA voltage transducers willonly require an external power supply if a biased4…20mA output is required. These transducersrequire a full specification before manufacture cantake place, these settings cannot be changed by theuser. The 3CC and 3VC are triple versions and arehoused in the larger 150mm case.
• Technical specification• Current nominal input 1 or 5A In• Current range of use 0 to 200% In• Current burden 1.5VA (0.6VA
biased output)• Current overload 3 x In continuous
25 x In for 3s50 x In for 1s
• Voltage input range 63.5 to 440Vn• Voltage range of use 0 to 150% Vn• Voltage burden 1.0VA (0.3VA
biased output)• Voltage overload 1.5 x Vn continuous
2 x Vn for 10s• Frequency range 45/55 or 55/65Hz
• Acuracy of the analogue output• Nominal accuracy 0.2%• Current reference range 0 to 200% In
(except biased output 0 to 100% In)• Voltage reference range 25 to 150% Vn
(except biased output 20 to 100% Vn)
> AC True RMS Current and Voltage
The 3CD current and 3VD rms voltage transducerscan be supplied with either an ac or dc auxiliarypower supply. These transducers require a fullspecification before manufacture can take place,these settings cannot be changed by the user. The3CF and 3VF are triple versions and are housed inthe larger 150mm case.
The 3VX is a variant of the 3VD but is supplied witha suppressed characteristic.
True zero outputs Model number reference
0 … 1mA A0 … 5mA B0 … 8mA C0 … 10mA D0 …. 20mA E0 … 5 … 10mA H1 … 0 … 1mA J10 … 0 … 10mA K0 ... 10V L 10 ...0...10V M0 ... 5V N 5 ...0...5V P
4>5
• Technical specification• Current nominal input 1A or 5A In• Current range of use 0 to 160% In• Current burden 0.3VA • Current overload 3 x In continuous
25 x In for 3s50 x In for 1s
• Voltage input range 63.5 to 440V, Vn• Voltage range of use 0 to 150% Vn• Voltage burden 0.1VA • Voltage overload 1.5 x Vn continuous
2 x Vn for 10s• Frequency range 45/55 or 55/65Hz
• Acuracy of the analogue output• Nominal accuracy 0.2% of reading• Current reference range 10 to 160% In• Voltage reference range 80 to 120% Vn
• Pulse output contact rating• Maximum switching power 10W, 10VA• Maximum switching voltage 125Vdc, 250Vac• Maximum switching current 0.5A• Isolation
750V rms between open circuits, 1kVrms between analogue output and relay contacts
> Watts, Vars, phase angle and power factor
These transducers can be supplied with either an acor dc auxiliary power supply with the exception of the3WF# and 3RF # which also have the option ofusing the 3B Dc/Dc converter. These transducersrequire a full specification before manufacture cantake place, these settings cannot be changed by theuser.
• Acuracy of the analogue output
• Technical specification• Current nominal input 1A or 5A In• Current range of use 0 to 160% In• Current burden 0.3VA • Current overload 3 x In continuous
25 x In for 3s50 x In for 1s
• Voltage input range 63.5 to 440V, Vn• Voltage range of use 0 to 150% Vn• Voltage burden 0.1VA • Voltage overload 1.5 x Vn continuous
2 x Vn for 10s• Frequency range 45/55 or 55/65Hz
Connection Watts Vars Phase Angle
single phase 3WA 3RA 3PA
3 phase, 3WB 3RB 3PB3 wire balanced,1El
3 phase, 3WC 3RN 3PC4 wire balanced, 1El
3 phase, 3WD 3RD 3PD3 wire unbalanced,2 El
3 phase, 3WE 3RH 3PE4 wire unbalanced, 2.5 El
3 phase, 3WF # 3RF # N/a4 wire unbalanced, 3 El
Phase difference N/a N/a 3PG
Nominal accuracy 0.19% of reading plus 0.01% full scale except 3P which are +1 degree
Current reference range 10 to 160% In
Voltage reference range 3W 40 to 150% Vn3R 40 to 150% Vn 3P 20 to 150% Vn .
TRANSDUCER OUTPUTS
AUXILIARY SUPPLY OPTIONS
AC Voltage Model number reference
Self powered A63.5V B69.3V C100V D110V E115V F120V G208V H220V J230V V240V K380V L415V M440V N
DC Voltage Model number reference
24V P32V R48V S110V T125V U12V WFrom 3B converter X
Biased outputs Model number reference
4 … 20mA F4 … 12 … 20mA G
> Tap Position Indication
The 3DA indicates the tap position by measuring thetap resistance proportional to the actual tapposition. The 3DA has a maximum of 33 taps.
These transducers require a full specification beforemanufacture can take place, these settings cannotbe changed by the user
• Technical specification• Resistance input 50 to 10,000 ohms• Input impedance 1M ohm
• Acuracy of the analogue output• Nominal accuracy 0.5%
> Tap Position Indication resistor box
The 3EA is a resistor box that is used with the 3DAto show the position of the tap changer. Each casehas 26 terminals and so a maximum of 25 resistorscan be wired out.
> DC Voltage and current
The 3DB voltage and 3DC current transducersmeasure DC values and convert them to aproportional DC analogue value.
These transducers require a full specification beforemanufacture can take place, these settings cannotbe changed by the user
• Technical specification• Current nominal input 1mA to 20mA• Current range of use 0 to 120% In• Voltage input range 10mV to 500V• Voltage range of use 0 to 120% Vn• Input impedance 1M ohm
(10mV to 1V dc)1K ohm/V (1V to 500V dc)
• Acuracy of the analogue output• Nominal accuracy 0.2%• Current reference range 0 to 120% In• Voltage reference range 0 to 120% Vn
> 3B DC/DC CONVERTER
The 3B provides an isolated DC/DC power supply with the exception of the 3BG which is non isolated.The 3B is only designed for use with the ISTAT I300 transducer.
The type and output voltage are:
3BA 24V dc 3BD 110V dc3BB 32V dc 3BE 125V dc3BC 48V dc 3BG 220/48V dc
ISTAT I300: comprehensive dc measurement range
ORDERING INFORMATION
> The ISTAT I300 model number comprises of 10 digits, the first 6designates the basic type of transducer whilst the next 3 are specificto the customers precise configuration. The last digit is for designsuffix.
Depending on the transducer, the following information is also required :
Input parametersVoltage, Current and power in secondary valuesTransformer ratios and voltage, current and power in primarly values
Scaling information : Output parametersHow is the analogue output configured, is it based on primary orsecondary values, and what do the maximum and minimum analogueoutputs scale to.
> 3B DC/DC CONVERTERThe DC/DC converter follows a different model numbering systemusing only 6 digits.
Note : the 3BG has only a single output, but this can be used to supplyupto 8 3BC 48V converters.
> 3EA RESISTOR BOXThe 3EA resistor box has 9 digits in the model number, the first 3 identify the type, the next 2 digits the number of resistors, the next 3 digits the resistor values and the last digit being the design suffix.
A special 3EA resistor box has been designed for use with the MICOM KVGC voltage regulation relay, this is called 3EA22A390A
1 2 3 4 5 63 W D K E 5
Basic Type, eg Watt 3ph 3wire
See Transducer output table, page 4See Auxiliary Supply Options table, page 4
Frequency
1 2 3 4 5 63 B C 0 0 1
Basic Type, eg 48V
Number of outputs, eg 1or 2 (note)
1 2 3 4 5 6 7 8 9
3 E A 2 2 3 9 0 BTypeNumber of resistors, eg 22
Resistor value, eg 390 ohmsDesign suffix, eg B
6>7
• Dc Technical specification• Voltage input 12 to 125V, Vx • Operating range 80 to 140% Vx• Power supply burden 2VA
> Compliance and open circuit voltage on the analogue output
• Compliance voltage 15V (note below)• Open circuit voltage 25V
Note: The compliance voltage for mean sensing 0...1mAoutput is 12V, for combined Watt/Var is 11V.
> Temperature
Reference range 0 … 50 Cexcept 3F 0 …. 40 C
Temperature 0.008%/ Cco-efficient except 3VX 0.04%/C
3F class 0.1Hz 0.004%/C 3F class 0.01Hz 0.001%/C3P 0.02 degree / C
Nominal -10 . . . +60 Crange of use
> Applicable standards
• Isolation4kV rms 50Hz for 60 seconds
• Impulse test5kV (1.2/50us) for BS923 and IEC 60255-22-1
• Surge withstandIEC 60255-22-1 and ANSI C37-90A IEEE std 472 SWC where applicable
• Electromagnetic compatibilityEN50081-2:1994 EmissionsEN50082-2:1995 ImmunityDirective 89/336/EEC
• Safety requirementsEN61010-1:1993Directive 72/23/EEC
• Humidity, non condensing 93% RH
> Resistance
The 3DL (3-wire measurement) transducermeasures a resistance value and converts this to aproportional DC analogue value. The 3DL isdesigned for use with PT100 temperature probes.
These transducers require a full specification beforemanufacture can take place, these settings cannotbe changed by the user.
• Technical specification• Resistence input 10 to 300 ohms• Input impedance 1M ohm
• Acuracy of the analogue output• Nominal accuracy 0.5%
> Temperature (thermocouple)
The 3DH transducer measures temperature andconverts this to a proportional DC analogue value.The 3DH is designed for use with thermocouples.The 3DJ also offers cold junction compensation(CJC).
These transducers require a full specification beforemanufacture can take place, these settings cannotbe changed by the user.
• Technical specification• Voltage input 5mV to 50mV, Vn• Input range 0 to 120% Vn• Input impedance 1M ohm
• Acuracy of the analogue output• Nominal accuracy 1.0%• Voltage reference range 0 to 100% Vn
TECHNICAL SPECIFICATION
> Auxiliary supply
Transducers can be supplied as self powered, dc or ac powered.
• Ac Technical specification• Voltage input 63.5 to 440V , Vx• Operating range 80 to 120% Vx• Frequency range 45 - 65Hz• Power supply burden 2VA
CASE OUTLINE AND FIXING DETAILS
55
5535
TerminalNo.1
10,7 Terminalpitch
DIN rail fixing35 x 7,5 DIN railto spec EN 50 022(B.S. 5584)
7478
1201,5
3
128
2 Holes Ø5,4 to accept M5 stud fixingas alternative to DIN rail
Outline of 55mm case
9
60
407,5
Detachable terminal covers
150
5535
Terminal No.110,7 Terminal
pitch DIN rail fixing35 x 7,5 DIN railto spec EN 50 022(B.S. 5584)
7478
1201,5
3
Detachable terminal covers
128
4 Holes Ø5,4 to accept M5 stud fixingas alternative to DIN rail
Outline of 150 mm case
9
60
1357,5
AU
TOM
AT
ION
-L3-
I300
-BR
-07.
05-1
039-
GB
- ©
- A
RE
VA
- 2
005.
AR
EV
A,
the
AR
EV
A lo
go a
nd a
ny a
ltern
ativ
e ve
rsio
n th
ereo
f ar
e tr
adem
arks
and
ser
vice
mar
ks o
f A
RE
VA
.IS
TAT
and
MiC
OM
are
reg
iste
red
trad
emar
ks o
f A
RE
VA
.All
trad
e na
mes
or
trad
emar
ks m
entio
ned
here
in w
heth
er r
egis
tere
d or
not
, ar
e th
e pr
oper
ty o
f th
eir
owne
rs.
- 38
9191
982
RC
S P
AR
IS -
Prin
ted
in F
ranc
e -
SO
NO
VIS
ION
-IT
EP
AREVA T&D Worldwide Contact Centre:http://www.areva-td.com/contactcentre/Tel.: +44 (0) 1785 250 070
www.areva-td.comwww.areva-td.com/measurements
Our policy is one of continuous development. Accordingly thedesign of our products may change at any time. Whilst everyeffort is made to produce up to date literature, this brochureshould only be regarded as a guide and is intended forinformation purposes only. Its contents do not constitute an offerfor sale or advise on the application of any product referred to init. We cannot be held responsible for any reliance on anydecisions taken on its contents without specific advice.