AG-Metal Zenica - tretman otpadnih voda:- Tehnologija tretmana otpadnih voda,- Prodaja opreme za tretman otpadnih voda,- Consulting i potpora za projektante i investitore- Zakoni i propisi iz oblasti tretmana otpadnih voda u zemljama regijezapadnog BalkanaO tretmanu otpadnih voda više na www.ag-metal.baAG-Metal Zenica - wastewater treatment:- Waste water treatment technology,- Sale of equipment for wastewater treatment,- Consulting and support for planners and investors- Laws and regulations in the field of wastewater treatment incountries of the region Western BalkansThe treatment of wastewater more on www.ag-metal.ba
Citation preview
INSTALLATION
USE
DESCRIPTION
CAPACITY
PRODUCT CATEGORY
PRODUCT NAME
APPLICATION
FAMILY
FROM 5 TO 180 INHABITANTS EQUIVALENT
68
FAMILY is a grease trap entirely made of high density polyethylene and suitable for private residences or small buildings installation.
Grease traps are important components in wastewater treatment and are utilized for the preliminary treatment of gray water sewage coming from kitchen sinks, washing machines, wash tubs and showers. The volume of a grease trap tank is designed to provide an adequate residence time of the incoming wastewater. During this period fats, oils and greases (FOG) are separated from the water by the physical process known as flotation which takes place because the specific weight of these substances is equal or less than the one of the water, therefore in non turbulent conditions, they float on the surface of the tank from where they can be easily removed.Inside grease trap also sand, debris and other suspended solids are separated from the water and having a greater specific weight they settle on the bottom of the tank.
ISEA’s grease trap FAMILY is provided with PVC inlet and outlet piping. Access to the plant is by two inspections portholes, one in the flotation chamber and the other by the outlet pipe. Both ports are protected by screw-on covers.
EXCAVATION Dig a hole of appropriate dimensions. The bottom of the excavation must be leveled and compacted with a 10 cm layer of fine sand (grain size 0-5 mm).
PVC pipes and fittings are utilized for connecting the grease trap to the inlet and outlet lines.
Periodically verify that no large bodies obstruct the sewage inlet or outlet by opening the inspection ports. Also, check that no sand obstructs the outlet pipe.At least once a month check that the grease is not lower than the outlet pipe. Floating material must be removed periodically using a specialized company and disposed in appropriate sites.
PIPING AND FITTINGS
PERIODIC CHECKS AND MAINTENANCE
GREASE TRAP
PRE-TREATMENT OF GRAY WATER SEWAGE
BACKFILLING Fill the tank with clean water before backfilling to avoid collapse of the polyethylene structureduring backfilling. Once the tank is full, dump sand around the tank and level it. For a walk-onsolution build a 5 cm thick light concrete layer on top of the tank and finish with a 40 cm thick soil. For a drive-on solution a reinforced concrete slab is required to protect the tank. Accessible manholes are required for inspection and maintenance.
AM
PL I
AM E N TO GAMM
A
FFAMILAMILYY
Certified Quality System
P
TE NTED
L I C E N C E
A
INFO
69
ØEØE
ØUØU
HE
l
b a
L
HU
H
grease chamber inspectionoutlet pipe inspection
grease chamber inspection
outlet inspection
l
b
L
HEHU
H
Mod. 125Mod. 250Mod. 350
Mod. 400Mod. 800Mod. 1200Mod. 1500Mod. 2000Mod. 3000Mod. 4000Mod. 5000
grease
inert material
grease
inert material
a
Performance Grease trap FAMILY is designed in accordance with DIN 4040 and ISEA guarantees the removal of 90% of the floating materials.
FAMILY - Grease trapCode Item D/LxP H HE HU øE øU a b
(litri) (cm) (cm) (cm) (cm) (mm) (mm) (mm) (mm)
0513 "Family" 125 5 ___ 100 60x68 62 43 40 110 100 100 200
0514 "Family" 250 10 ___ 200 60x68 82 63 60 110 100 100 200
0515 "Family" 350 15 ___ 300 60x68 100 83 80 110 100 100 200
0511/1 "Family" 400 20 ___ 400 80x80 80 62 58 110 100 100 400
0511/2 "Family" 800 25 ___ 600 80x80 120 102 97 110 100 100 400
0511/3 "Family" 1200 35 100 1200 120x120 120 95 92 110 100 100 400
0511/4 "Family" 1600 50 200 1600 120x120 160 125 120 125 125 100 400
0511/5 "Family" 2000 80 300 2000 120x120 200 175 170 140 140 100 400
0511/6 "Family" 3000 100 400 3000 160x160 160 125 120 140 140 100 400
0511/7 "Family" 4000 150 600 4000 160x160 200 175 170 160 160 100 400
0511/8 "Family" 5000 180 750 5000 160x160 240 215 210 160 160 100 400
DIM
ENSI
ON
S &
DES
IGN
E.I. Seats Capacity