Upload
amethyst-norton
View
20
Download
1
Embed Size (px)
DESCRIPTION
ISE 6 Phase 2 Demo Scenario. Sept 11, 2008 NSWC CD. Current Issues. Confirm data exchange scenario Define level of NSWC PHD / Raytheon participation Discuss details of IPT CAD modeling Start to define demo data HVAC system HVAC system PLCS logistics data HVAC system S1000D modules. - PowerPoint PPT Presentation
Citation preview
ISE 6 Phase 2 Demo Scenario
Sept 11, 2008
NSWC CD
2
Current Issues
• Confirm data exchange scenario
• Define level of NSWC PHD / Raytheon participation Discuss details of IPT CAD modeling
• Start to define demo data– HVAC system
– HVAC system PLCS logistics data
– HVAC system S1000D modules
3
ISE 6 Phase 2 Demo Scenario• Dual Band Radar, provided by NSWC PHD, is incorporated into LPD 17
and DDG 1000 design.
• Export selected Dual Band Radar system from LPD IDE as PLCS data with S1000D data modules
• PLCS data modified to allow importation into DDG 1000 IDE
• PLCS data imported into DDG 1000 IDE
• New Mod of Dual Band Radar is developed and authorized for use
• New radar cabinets generate more heat, require additional cooling in the space
• New cooling requirements passed to Shipyard Engineering
• HVAC system is redesigned
• Affected S1000D data modules for HVAC system IETM are updated
• HVAC system IETM updated
• Updated design passed to LEAPS
4
PLCS & S1000D: Functional Scenario
Shipyard B Design(3D CAD Data)
Shipyard B IDE(Update Tech Pub)
Navy IDE(Design & Analysis)
Shipyard A IDE(Design, Logistics, Support)
Data Prep & QA(Design, Logistics, & CAD)
Navy ISEA(GFE Change)
5
TeamcenterDDG 1000 IDE Software
LEAPSNavy Design & Analysis
Repository
ShipConstructor2006
ShipConstructor2008
Design
Navy IDEAIM/SIR
LPD 17 IPDE Software
Shipyard A IDE
Shipyard B IDE
episTreeKnowledge Management
Software
3D Design
New Support Requirements
AP 239 + S1000D
AP 227HVAC
AP 227HVAC
AP 239 + S1000D
Common Source DB
NAVSEA / Navy ISEA
Ship AltChanges
PLCS & S1000D: Exchange Scenario
AP 239 Radar data
6Updated
Requirements
PLCS & S1000D: Data Scenario
DM 1.1
DM 1.2
DM 1.3
Chillers
Duct 1
Chiller 2
Duct 2
HVAC SysDrawing2
DM 2.3
DM 2.2
HVAC SysIETM 1
HVAC SysIETM 2
ISEA IDE (Radar)
DM 1.1
DM 1.2
Mod 1RadarIETM
Mod 1
DM 1.3Mod 2
DM 2.1
Mod 2RadarIETM
DM 2.2
Chiller 1
HVAC Sys
HVAC Ducts
HVAC SysDrawing1
Shipyard Design & IDE
7
Demo Data
• HVAC system PLCS data– Similar to last year’s demo
– Equipment – chiller?
– AP 227 implications
• HVAC system Tech Manual / Data Modules– Need to define minimal TM content, divide into DM
– Define DMC structure
– Define necessary metadata
8
Backup
9
AIM/SIRLPD 17 IPDE Software
TeamcenterDDG 1000 IDE Software
episTreeKnowledge Management
Software
LEAPSNavy Design & Analysis
Repository
CATIA(V4 AEC)
ShipConstructor2006
ShipConstructor2008
AP 227
AP 227
AP 239
AP 214
Design Navy IDE
Shipyard A - IDE Shipyard B - IDE
3D Design
Design & Logistics
Design & Logistics
AP 214
AP 239
Design & Logistics,including 3D Design
AP 239
AP239/PLCS (ISE-6 Phase 1) Demo Scenario
10
PLCS & S1000D: Functional Scenario
Shipyard A Design(3D CAD Data)
Shipyard A IDE(Update Tech Pub)
Navy IDE(Design & Analysis)
Navy Depot(Design, Logistics, Support)
Data Prep & QA(Design, Logistics, & CAD)
Navy ISEA(GFE Change)