15
Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. इंटरनेट मानक !ान $ एक न’ भारत का +नम-णSatyanarayan Gangaram Pitroda “Invent a New India Using Knowledge” प0रा1 को छोड न’ 5 तरफJawaharlal Nehru “Step Out From the Old to the New” जान1 का अ+धकार, जी1 का अ+धकारMazdoor Kisan Shakti Sangathan “The Right to Information, The Right to Live” !ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता ह Bharthari—Nītiśatakam “Knowledge is such a treasure which cannot be stolen” IS 8105 (1976): Method for sensory evaluation of pungency of black pepper by scoville heat units [FAD 9: Spices and Condiments]

IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

Disclosure to Promote the Right To Information

Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public.

इंटरनेट मानक

“!ान $ एक न' भारत का +नम-ण”Satyanarayan Gangaram Pitroda

“Invent a New India Using Knowledge”

“प0रा1 को छोड न' 5 तरफ”Jawaharlal Nehru

“Step Out From the Old to the New”

“जान1 का अ+धकार, जी1 का अ+धकार”Mazdoor Kisan Shakti Sangathan

“The Right to Information, The Right to Live”

“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता है”Bhartṛhari—Nītiśatakam

“Knowledge is such a treasure which cannot be stolen”

“Invent a New India Using Knowledge”

है”ह”ह

IS 8105 (1976): Method for sensory evaluation of pungencyof black pepper by scoville heat units [FAD 9: Spices andCondiments]

Page 2: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0
Page 3: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0
Page 4: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0
Page 5: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

IS : 8105 - 1976

Indian Standard METHOD FOR SENSORY EVALUATION OF

PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS

Sensory Evaluation Sectional Committee, AFDC 38

Chairman

SHRI M. R. SRINIVASAN

Members

DR K. T. ACHAYA

AGRICULTURAL MARKETING ADVISER TO THE GOVERN~~ENT OF

Representing

National Dairy Research Institute ( ICAR ), Karnal

Protein Foods and Nutrition Development Associa- tion of India, Bombay

Directorate of Marketing & Inspection ( Ministry of Agriculture & Irrigation ), Faridabad

INDIA SHRI T. V. MATHEW (Alternate )

SHRI D. S. CHAD~A Cent;l$;;nittee for Food Standards ( DGHS ),

DR J. D. CONTRACTOR The C&a-Cola Export Corporation, New Delhi SHRI P. C. VAN ( Alternate )

KUMARI I. F. COOPER Naarden ( India ) Limited, Bombay SHRI S. B. SULE ( Alternate )

DR G. I. D’ SOUZA Coaee Board, Bangalore SHRI A. V. R. MENON ( Alternate )

SHRI V. S. GOVINDARAJAN Central Food Technological Research Institute ( CSIR ), Mysore

DR K. G. RAGHUVEER ( Alternate ) DR M. K. K. IYENGAR Food Specialities Limited, Moga DR B. K. JHA McDowell & Co Ltd, Shertallay DR GURBHAGWANT SINGH KALHON The Punjab Dairy Development Corporation

Limited, Chandigarh SHRI B. M. L. GARG ( Alternate )

SHRI A. MADHAVA RAO Bush Boake Allen ( India) Limited, Madras SHRI K. S. SUBRAMANIYAM (Alternate )

SHRI T. K. D. MENON Tea Board, Calcutta DR M. K. NAGARAJAN Hindustan Lever Limited, Bombay

SHRI K. S. JANARDHANAN ( Alternate ) DR A. G. NAIK-KURADE SHRI S. N. PANDEY

Suman Food Consultants,. New Delhi All India Distillers’ Association, New Delhi

SHRI B. L. KHANNA ( Alternate ) SHRI M. V. RAMA RAO Defence Food Research Laboratory, Mysore

SHRI H. UMESH RAO ( Alternate )

( Continued on page 2 )

@ Copyright 1976

INDIAN STANDARDS INSTITUTION

This publication is protected under the Indian Copright Act (XIV of 1957) and reproduction in whole or in part by any means except with written permission of the publisher shall be deemed to be an infringement of copyright under the said Act.

Page 6: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

IS : 8105 - 1976

( Continuedfrom page 1)

Members

SHRI C. K. RAMNATH BRIG D. S. RAO

Repesenting

Brooke Bond India Limited, Bangalore Technical Standardization Committee (Foodstuffs )

( Ministry of Agriculture & Irrigation ), New Delhi

SHRI J. K. JAGTIANI ( Alternate) COL K. SEETARAM Quartermaster General’s Branch, Army Head-

LT-COL G. L. LUTHRA ( Alternate ) quarters

SHRI N. D. SUBBA RAO United Breweries, Bangalore SHRI T. PURNANANDAM,

Deputy Director ( Agri & Food ) Director General, IS1 ( Ex-ojicio Member)

Secretary

SHRI SOHRAB

Deputy Director ( Agri & Food ), IS1

Sensory Evaluation of Spices and Condiments Subcommittee, AFDC 38 : 4

Convener

SHRI V. S. GOVINDARAJAN

Members

Central Food Technological Research Institute ( CSIR ) , Mysore

SHRI K. C. ABRAHAM Bolst’s Indian Condiments ( Private ) Ltd,-Bangalore SHRI M. S. BYRAUNA ( Alternate j

AGRICULTURAL M A R i E T I N c ’ Directorate of Marketing & Inspection ( Ministry of ADVISER TO THE GOVERNMENT OF Agriculture & Irrigation ), Faridabad INDIA

SHRI T. V. MATHEW ( Alternate ) SHRI J. M. GANDHI Messrs Gandhisons, Bombay

SHRI I. A. GANDHI ( Alternate ) &RI K. S. JAYARAMAN Defence Food Research Laboratory, Mysore

SHRI T. C. SATYANARAYANA ( Alternate ) SHRI P. B. KURUP SHRI L. R. MADHUSUDAN

Techno Chemical Industries Limited,. Kozhikode The Spices Export Promotion Councrl, Ernakulam

SHRI AVINASH K. MARATHE Saiba Industries Ltd, Bombay SHRI K. V. MARIWALA The Bombay Oil Industries Private Ltd, Bombay SHRI M. K. K. MENON Brooke Bond India Limited, Bangalore

SHRI E. C. JOSEPH ( Alternate ) SHRI R. N. RAMANI Sri Ganeshram’s Analytical Laboratories, Madras COL K. SEETARAM Quartermaster General’s Branch, Army Head-

quarters LT-COL D. D. VOHRA ( Alternate)

2

Page 7: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

IS: 8105.1976

lndian Standard METHOD FOR SENSORY EVALUATION OF

PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS

0. FOREWORD

0.1 This Indian Standard was adopted by the Indian Standards Institution on 7 July 1976, after the draft finalized by the Sensory Evaluation Sectional Committee had been approved by the Agricultural and Food Products Division Council.

O-2 Pungency is an important factor in the evaluation of quality of black It is attributed to some of the non-volatile constituents of the

/?%erpepper. Determination of these constituents by chemical and instrumental means has relevance only when related to the measure of the pungency perceived sensorily in the terms of recognition threshold.

0.3 In the preparation OF this standard, considerable assistance has been derived from the research investigations carried out at the Central Food Technological Research Institute, Mysore.

0.4 This standard is complementary to IS : 1798-1961*.

0.5 In reporting the result of a test or analysis made in accordance with this standard, if the final value, observed or calculated, is to be rounded off, it shall be done in accordance with IS : 2-19607.

1. SCOPE

1.1 This standard prescribes a method for sensory of black pepper by Scoville heat units ( SHU recognition threshold.

evaluation of pungency ) corresponding to the

1.2 This procedure is applicable to pepper powder and pepper oleoresin and the tables provided cover the range of 1 to ~8 percent piperine in powder and 10 to 80 percent piperine in oleoresin.

2. TERMINOLOGY

2.0 For the purpose of this standard, the following definition shall apply.

*Specification for black pepper, whole and ground. iRules for rounding QK nuxnewal values ( revised ).

3

Page 8: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

IS : 8105 - 1976

2.1 Scoville Heat Unit ( Recognition Threshold ) - The reciprocal of the highest dilution of black pepper or its extracts at which a defined panel identifies pungency.

3. OPTIMUM REQUIREMENTS

~3.1 Optimum requirements for sensory evaluation of the pungency of black pepper shall be as described in IS : 6273 ( Part I )-1971*.

4. PRINCIPLES

4.1 Preliminary evaluation of the oleoresin sample of known piperine content or pure piperine is done for the purpose of the definition of the panel sensitivity.

4.2 Evaluation of test samples is done by the selected panel by regular recognition threshold test with dilution series of definite concentration steps as around the just noticeable difference (JND ).

5. REAGENTS

5.1 Unless specified otherwise, pure chemicals and distilled water (see IS : 1070-1960t ) shall be employed.

NOTE - r Pure chemicals ’ shall mean chemicals that do not contain impurities which affect the test results.

5.2 Ethanol - 95 percent.

5.3 Sodium Chloride Solution - 0.75 percent in water.

6. APPARATUS

6.1 Round-Bottom Flask with Reflux Condenser - 200 ml.

6.2 Volumetric Flask - 100 ml.

6.3 Pipettes - 1 ml capacity, graduated in 0.01 ml; and 5, 10 and 20 ml capacities, graduated in 0.1 ml.

6.4 Analytical Balance

66 Beakers - 25 ml capacity with 5 ml marking.

7. PROCEDURE

7.1 Preparation of Stock Solution

7.1.1 Pepper Powder - Reflux 2 g of pepper powder ( about 20 mesh ) for 3 hours with 100 ml 95 percent ethanol. Filter by suction and wash the

*Guide for sensory evaluation of foods: Part I Optimum requirements. tSpecification for water, distilled quality ( revised ).

4

Page 9: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

IS t 8lO5 - 1976

residue with ethanol. Make up volume to 100 ml with ethanol. The stock solution corresponds to a dilution of 1 : 50.

7.1.2 Pepfier Oleoresin - Dissolve O-2 g of oleoresin in 100 ml ethanol. The stock solution corresponds to a dilution of 1 ~500.

7.2 Instructions for Sensory Testing for Pungency

7.2.1 Carry out the evaluation with the minimum time lapse between preparation of sample and testing ( within 20 to 30 minutes ) as loss of pungency occurs in aqueous medium of extracts of pepper due to the low solubility and recrystallization of piperine, the pungent component.

7.2.2 Carry out the tests as threshold tests as prescribed in 4.3.1 of IS : 6273 ( Part II)-1971 *.

7.2.3 Give 4 to 5 dilutions ( 5 ml) of the test solution in a sequential order starting from the highest dilution. Use varying number of blanks ( 1 to 3 ) at the beginning of test series. Code all the samples in the series.

7.2.4 Recognize the bias due to the aroma of pepper reached before pungency threshold level.

7.2.5 Allow sufficient time lapse ( 10 to 20 seconds ) between samples. Do the palate clearing rigorously as given in Appendix A.

7.2.6 Use the score card given as in Appendix A. Stop the testing when a definite pungent sensation is felt while testing in geometric series as the next sample may have high pungency.

7.3 Preliminary Testing

7.3.1 The panel leader should first do the preliminary testing with a larger common ratio ( say 1 : 5 ) in making dilutions, to avoid great deal of waste of time by giving solutions which could be either too dilute or too strong. This also helps to present the minimum number of test solutions to the panelists.

7.3.2 After identifying approximately the dilution of a sample where pungency is felt, prepare the dilutions in a geometric series with a closer common ratio ( say 1 : 2 ) for preliminary testing by the panel.

For example, if the panel leader identifies pungency, around 40 x IO2 SHU in pepper powder and around 310 x lo2 SHU in pepper oleoresin, the following series could be used for the panel.

Place the indicated volume of stock solution in 10 ml volumetric flask and make up to volume with sodium chloride solution.

*Guide for sensory evaluation of foods: Part II Methods and evaluation cards.

5

Page 10: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

IS : 8105 - 1976

Pepper Powder Pejber Oleoresin ~---_-_-A-- ---a A ----- -----7 Stock Solution in SHU x lo2 Stock Solution in SHU x lo2

ml ( see 7.1.1) ml ( see 7.1.2 )

0.92 54 I.30 385

1.10 45 l-56 321

1.32 38 I.87 267

1.59 31 2.25 222

1.91 26 2.70 185

7.3.3 Test the dilution series of one or two samples as a threshold test on a group of panelists ( 10 to 12 ) willing to participate in the tests. Use two sessions to educate the panel on the sensation perceived, group the panelists as of higher or lower sensitivity by their threshold value, based on the group means, and to fix the approximate threshold of the sample corresponding to the selected panel as in 8.2.

7.4 Final Evaluations

7.4.1 Prepare the dilutions from stock solutions in an arithmetic series around the approximate threshold value identified by the panel in 7.3.3, which should differ in concentration by approximately the JND ( which is usually O-08 to 0.11 the threshold value ). This series may be obtained by reference to appropriate levels in Appendices B and C or calculated for intermediate dilutions according to the formulae given. For example, if the approximate threshold is around 38 x lo2 SHU for pepper powder and 320 x lo2 SHU for pepper oleoresin, the following two series may be used.

Place the indicated volume of the stock solutions in a loo-ml volume- tric flask and make up to volume with sodium chloride solution.

Pepper Powder Pepper Oleoresin ~~~~~h~~~~~~ r_-__-h-_-__~ Stock Solution in SHU x lo2 Stock Solution in SHU x IO2

ml ( see 7.1.1 ) ml ( see 7.1.2 )

1.09 46 1.35 370

1.19 42 1.47 340

1.32 38 l-61 310

1.47 34 l-79 280

167 30 2.00 258

6

Page 11: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

7.4.2 Conduct the final test as a threshold test with the selected homo- genous panel of a minimum of 5 panelists. Repeat 3 to 4 times to get 15 to 20 judgements taking care that the dilution series are different for each session to avoid positional bias.

8. PRESENTATION OF DATA

8.1 Decode the test series in terms of Scoville heat units ( SHU ).

8.2 For threshold value, take the Scoville heat units ( SHU ) corresponding to X; when intermediate scale values such as, ? - X and X - 1 are given for successive samples in the series, the mean of the Scoville heat units corresponding to these two dilutions may be taken.

8.3 As the threshold values recorded show sudden day-to-day variations constant check for individual panelist’s sensitivity may be made and values widely differing from normal should be deleted. Calculate the arithmetic mean of the panel threshold values. Individual values, which are lower by more than one-tenth ( approximately one JND ) of the panel average may be disregarded.

8.4 Calculate the arithmetic mean and standard deviation for the remain- ing values. A minimum of 15 values may be used.

8.5 Define the panel by the average threshold -& 1 $ for pure piperine or an oleoresin of known piperine content from data collected under 7.4.

9. TEST REPORT

9.1 The pungency of the sample in Scoville heat units ( SHU ) should be reported as range and mean f 1 8, in hundreds ( X 102 ),

9.2 The test report should also contain the definition of panel as prescribed in 8.5 so that results from different panels on the same sample may be related.

7

Page 12: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

is : Ii(i5 - 1976

APPENDIX A

( Clauses 7.2.5 and 7.2.6 )

SCORE CARD FOR THRESHOLD TEST FOR PUNGENCY IN BLACK PEPPER

Name

INSTRUCTIONS

Date Time ____-

Taste the samples in the sequential order given.

Swallow slowly the whole quantity of the test sample.

Wait for few seconds to recognize pungency if any ( aroma suggesting pepper should not be confused for pungency )

Take some puffed rice and few sips of sugar or salt solution between samples

Describe the sensation of each sample using the intensity scale given below:

None or sugar or salt solution

Different from sugar/salt solution ( but pungency not identifiable )

Threshold ( pungency identifiable )

Weak

Medium

Strong

( Intermediate value is expressed by ?

Series I

Code No. . Intensity

8

-

0

? Stimulus threshold

X Recognition threshold

1

2

3

- X, X- 1, 1 - 2, etc.)

Series II

Code No. . Intensity

Page 13: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

IS : 8105 - 1976

APPENDIX B

( Clause 7.4.1 )

ARITHMETIC SERIES FOR PEPPER POWDER

Place the indicated volume of stock solution ( 2 g powder extract to 100 ml SHU, 0.5 x lo2 ) in 1 OO-ml volumetric flask and make up to volume with 0.7 oercent sodium chloride solution to obtain the correspond-

I

ing Scoville heat unit.

Stock Solution in ml ( see 7.1.1 )

SHU x IO2 SHU x 10" Stock Solution in ml (see 7.1.1 )

I .92

2.00

2.08

2.17

2.27

2-38

2.50

2.63

2.78

2’94

3.12

3-33

3.57

3.85

4.17

4.54

5.00

26

25

24

23

22

21

20

19

18

17

16

15

14

1 3

12

11

IO

0.59 85

0.62 80

0.71 70

0.77 65

0.83 60

0’91 55

I.00 50

1.11 45

1.25 40

1.32 38

1.39 36

1.47 34

1.56 32

1.67 30

1.72 29

1.79 21:

1.83 27

The dilutions for intermediate SHU should be calculated as follows:

Volume in ml of stock solution for dilution to 100 ml =

SHU x lo2 of stock solution x loo SHU x 10” required

9

Page 14: IS 8105 (1976): Method for sensory evaluation of pungency ... · IS: 8105.1976 lndian Standard METHOD FOR SENSORY EVALUATION OF PUNGENCY OF BLACK PEPPER BY SCOVILLE HEAT UNITS 0

k3:8105-1976

APPENDIX

( Clause 7.4.1 )

C

ARITHMETIC SERIES FOR PEPPER OLEORESIN

Place the indicated volume of stock solution ( 0.2 g oleoresin in 100 ml ethanol SHU, 5 x lo2 ) in loo-ml volumetric flask and make up to volume with 0.75 nercent sodium chloride solution to obtain the

A

corresponding Scoville heat unit.

Stock Solution in ml SHU x lo2 ( see 7.1.2 )

O-56 900

0.59 850

O-62 800

0.67 750

o-71 700

0.77 650

O-83 600

O-91 550

1’00 500

1.11 450

l-25 400

1.35 370

l-47 340

1.61 310

l-79 280

1.92 260

2.00 250

2.08 240

2-17 230

2.27 220

2-38 210

2.50 200

2.63 190

Stock Solution in ml ( see 7.1.2 )

2.78

2.94

3.12

3.33

3’57

3-85

4.17

4.55

5.00

5.56

5.88

6.25

6.67

7.14

7.69

8.33

9.09

10~00

11.11

12.50

14.29

16.67

20.00

SHU x lo2

180

170

160

150 140

130 120

110

100

90

85

80

75

70

65

60

55

50

G

40

35

30

25

The dilutionsfor intermediate SHW should be calculated as follows:

Volume in ml of stock solution for dilution to 100 ml = SHU X 1O’of stock solution x loo - ---~-~

SHU x lo2 required

10