Upload
naved-hava
View
340
Download
1
Embed Size (px)
DESCRIPTION
Is 14846-2000-Sluice Valve for Water Works Purpose(50 to 1200mm Size)-Specification
Citation preview
Gama * la-q
lS 14846-:2000(Superseding 1S780: 1984and 1S2908: 1984)
W-1-spl $) – mm
Indian Standard
SLUICE VALVE FOR WATER
(50 TO 1200 mm SIZE) —
WORKS PURPOSES
SPECIFICATION
ICS 23.060.30
0 BIS 2000
BUREAU OF INDIAN STANDARDSMANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARC
NEW DELHI 110002
—
(ktober 2000 Price Group 8
Sanitary Appliances and Water Fittings Sectional Committee, CED 3
FOREWORD
This Indian Standard was adopted by the Bureau of Indian Standards, after the draft finalized by the SanitaryAppliances and Water Fittings Sectional Committee had been approved by the Civil Engineering DivisionCouncil.
IS 780 was first issued in 1956 and the first, second, third, fourth, fifth and sixth revisions were issued in 1963,1966, 1967, 1969, 1980 and 1984, respectively. In this revision, the committee, following the practices atInternational level decided to merge IS 2906 in this standard.
For connections of sluice valves to a pipeline, certain situations may require the use of fittings like tail piecesand adapters. The requirement of these fittings are covered in IS 1538.
While formulating the Standard an attempt has been made of making this standard in line with other InternationalStandards formulated on the subject. Guidance has been taken from BS, AWWA, DIN, JR3and 1S0 standards.At the same time the practices followed in this field in the country have been kept in view.
The information to be supplied with enquiry and order by the purchaser is given in Annex. D.
The composition of the technical committee responsible for the formulation of this standard is given atAnnex F
For the purpose of deciding whether a particular requirement of this standard is complied with the final value,observed or calculated, expressing the result of a test or analysis shall be rounded off in accordance withIS 2:1960 ‘Rules for rounding off numerical values (revised)’. The number of significant places retained in therounded off value should be the same as that of the specified value in this standard.
—
IS 14846:2000
Indian Standard
SLUICE VALVE FOR WATER WORKS PURPOSES(50 TO 1200 mm SIZE) — SPECIFICATION
1 SCOPE
This standard covers requirements for non-rising stemtype sluice valves from 50 to 1200 mm sizes used forwater supply up to 45°C and having double flangedends for connections.
2 REFERENCES
The Indian Standards given in Annex E containprovisions, which throu_gh reference in this text,constitute provision of this standard. At the time ofpublication, the editions indicated were valid. Allstandards are subject to revision, and parties toagreements based on this standard are encouraged toinvestigate the possibility of applying the most recenteditions of the standards indicated in Annex E.
3 TERMINOLO-GY
For the purpose of this standard, the definitions,covered in IS 4854 (Part 1) shall apply.
4 NOMINAL PRESSURES
Sluice valves shall be designated by nominal pressure(PN) defined as the maximum permissible gaugewo~king pressure in MPa for the sizes indicated asfollows:
Nominal Pressure (PN) Nominal Sizes
MPa mm
PN 1.0 50 to 1200
PN 1.6 50 to 600
5 NOMINAL SIZES
5.1 Sluice valves shall be of the following sizes:
’50,65,80, 100, 125, 150,200,250,300,350, 400,450, 500, 600, 700, 750, 80-0,900, 1000, 1 100and 1 200 mm.
5.1.1 The nominal size shall refer to the nominal boreof the waterway. The actual bore at any point shallnot be less than the nominal size given in 5.1.
6 MATERIAL
The material for different component parts of sluicevalves shall conform to requirements given in Table 1.Where alternative materials are specified in Table 1,these may be used with the agreement of purchaser
except the combination(see 7.7).
7 MANUFACTURE
of stem and nut for wedge
—7.1 A typical illustration of a sluice valve is given inFig. 1A, lB and lC.
7.2 Bodies and Bonnets
7.2.1 Bodies and bonnets shall be so designed as towithstand the test pressure specified in 10.1.1. Thebodies of the valves shall be fitted with seat ringssecurely fixed in machined recesses.
7.2.2 The manufacturer shall provide a reasonableclearance behind the rear face of the flange on bodyand bonnet to provide free access to use spanners forassembling and dismantling.
7.2.3 The portions of bonnet (gland and stuffing box)which come in contact with spindle shall be providedwhenever required by the customer with bushings ofminimum 3 mm thickness and of material as specifiedin Table 1 as a anti-frictional devices.
7.2.4 The dimensions of sluice valve assemblies aregiven in Tables 2 and 3 read in conjunction withFig. 1A, lB and lC.
7.3 Flanges
The Flanges and their dimensions of drilling shall bein accordance with the requirements given in IS 1538unless otherwise specified by the purchaser in thecontract. The.requirements for valve sizes 50 mm and65 mm are given in Table 3A.
7.4 Wedges
7.4.1 Valves shall be fitted with double faced cast ironwedge made in one piece and having two machinedfacing rings securely fixed into machined recesses inthe wedge. When shut, the wedge-facing ring shallride high on the body seat ring to allow for wear. Theminimum wear travel shall be 25 percent of the facewidth (B) of the seat ring as given in Table 4 and readin conjunction with Fig. 2A and 2B.
7.4.2 The wedge faces shall be smooth finished andshall have an equal inclination of not less than 4° upto 600 mm size and not less than 2° in sizes 700 mmand above on each side of the face of the wedge.
1
IS 14846:2000
.Table 1 Materials for ‘Component Parts of Sluice Valve
(Clause 6)
T-_ -=; ~: ‘radeOrD’”i9a’iOn‘:~::: %; J2Wtr
+----
I) Body, bonne[. dome, Grey cast iron 210 FG 200 Spheroidal or 1865 260-300 / 12 or 500stool cover, wedge, Nodular”iron 12stuffing box, gland, Cast steel 1030thrust plate and cap
ii) Hand wheel Grey cast iron 210 FG 200 Mild steel 2062 F41OWACast steel 1030 230- 450WNodular iron 1865 400/12
iii) Slem Stainless steel 6603 12Cr 13 04Cr 18Ni 10 High Tensile 320 or HT204Cr 17Ni 12M02 Brass 6912 FHTB 2
Stainless steel 6603 20Cr13iv) Wedge nut, shoe, Leaded tin 318 LTB -2 High Tensile 320 HTB2
channel bronze Brass 6912 FHTB-2Phosphor bronze 28
v) Body seat ring, wedge Leaded tin 318 LTB -2 Alloy steel 3444 Gr. 1facing ring and bushes bronze Gr. 4
Gr. 10Stainless steel 6603 04Cr18Ni 10
vi) Bolts Carbon steel 1363 Cks 4.6 Stainless steel 6603(Part 1)
vii) Nuts Carbon steel 1363 class 4.0 Stainless steel 6603(Part 3)
viii) Gasket Rubber 638 Type B NeopreneRubber
ix) Gland packing Jute and 5414 Rubber 638hemp
Type B
x) Gear Spheroidal 1865 Gr500/7 Alloy steel 1570 40Ni2CrlM028graphite iron Gr B
:F
Cast steel 1030xi) Gear housing Grey cast iron 210 FG 200 Cast steel 1030 230-450 W
S.G. iron 1865 400/ 12xii) Pinion & pinion shaft Wrought 1570 C55Mn75 Alloy steel 1570 40 N]12Crl MO 28
cmlmn steel (Parr 3) (Part 4) 04Cr18Ni 10Stainless steel 6603
BONNET~
‘oD’---u
FACINGRING+--+
‘mBRID
l!t-1
—. +
~s D 1
—.—
FIG. 1A TYPICAL SKETCH OF A SLUICE VALVE FOR SIZE 150 mm &WITH THRUST PLATE
2
IS 14846:2000
~a K--————$D——————+
h?i!$I
—. J
HANDWHEEL
“O+ihlittd ~1 I
~AIR PLUG
STEM NUT
#
BODY k-k$l -WEDGE
FACING RING
PVVEDGE
L!J
r
y.
BODYSEAT RING
FLANGE.
VALVECTION
FIG. lB TYPICAL SKETCH OF A SLUICE VALVE FOR SIZE 200-mm @AND ABOVE
GGEARBOX—
THRUSTBEARING -3? fGIANC)
STOOLCOVERawi
I =AF!PL”G/l\
... —--
—-
\
—
-BYPASSVALVE
-BYPASSVALVE
FIG. 1C TYPICAL SKETCH OF A SLUICE VALVE WITH BALL THRUST BEARING AND SPUR GEAR ARRANGEMENT
3
Table 2 Dimensions of Sluice valves for Nominal F%essure PN 1.0(Clauses 7.2.4,7.7.1,7.9,7.11, 7.12,7.13 and Fig. 1A, lB, 4 and 5)
All dimensions in millimetres.
‘ ‘FFFRRF “:Fm‘epthE~FP‘sPD ALT-I
‘::- ‘“”Pr c ;. “ ‘2 t G ‘Mi”rr
F Min D x Y
(1) (2) (3) (4j (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) (21) (22)
i) 50 178 250 215 160 365 15 30 22 225 180 8 50 30 42 10 4 45ii) 65 190 270 230 215
225 35 60380 15 30 22 225 180 8 50 30 42 10 4 45
iii) 80 203 280 230 220225 35 60
425 15 30 22 240 190 8 50 30 42 10 4iv) 100 229 300 255
45250
225 35 60470 18 36 27 240 190 8 55 35 47 10
v) 1254
254 325 26645
310320 35 60
485 18 36 27 250 200 10 55 35 47 10 5vi) 150 267 350 280
55330
320 35 60595 18 36 27 250 200 10 55 35 47 10
vii) 2005
292 400 31855
460320 33 60
725 22 42 32 340 280 10 65 45 56 12viii) 250
5330 450 355
65495
360 35 60835 25 48 36 450 270 15 65 50 60 12 5
ix) 300 356 500 38065
585400 35 60
910 25 48 36 465 24Ll 15 70 50 60 12 5x) 350 381
65550 — 650
400 35 60I 0200 25 45 37 50 61 12 5
xi) 400 40665 500
rwm . 75(,48 75
“::, “<n “,m.- . . ..-
AX 7<
xiii) 500 457 700 I — 900xiv) 600 508 Rnn I — 1nsn,xv) 700 610 900 111300 1 150(
*6b 100 800 65 1:0
2CWL, .,.,””1 -“ , ““ , “,I I , 1 6
xvii) 1 800 660100 900
]1000011”2500 [1”30001193001 48 I 86 I 6777 .- 65 100
; QQ 161_ 6xviii) I mn I 71 I
100ltlnnnliasmnll~rv
900 65 100A
1--- 1 1 1 1100 31 54 42
*,,, , YJ” , .tJL 650 I — I ‘-”830 12000 34 64 47) 13000 34 64 47
i ““- 1 ,...-:0 15000 34 64 47‘“ o 16700 44 78 62
n I mm n AQ R& 67 B%+==-As per manufacturer’s design ~n ~fi
xvi) I 750 610 950 l1200dll
.. . .... .“- ,.. ..,,”” . a“., “ .-00 20800 53 88 77xix) 10000 811 12000 15000 15000 22000 53 88 77xx) 11000 $$ $$ 16500 16500 24500 63 99 87
xxi) 12000 $$ $$ 18000 18000 25800 63 99 87
NOTES1-PD Preferred diinensions (short body).2- ALT I Alternate I dimensions (long body).3 - ALT H Alternate II dimensions.4-$ Dimensions given under Alternate 11will stand deleted with effect from 01 April 2005.s - ($$) As and when kO stipulates, these dimensions will be notified.
Tolerances on Length L Other TolerancesUp to and including 30Umm *2mm Tolerances on Square, a and X * 0.5 mmAbove 300 and including 600 mm *3mm Tolerances on Length of Square, C * l.OmmAbove 600 and including 800 mm t 4 mm Tolerances cm Size of Hand Wheel, D * 5.0 mmAbove 800 and including 1000 mm * 5 mm Tolerances On Length between Square * 0.5 mmAbove I 000 mm *6mm
1“1-i .A. 65 100 ‘110 113 900 65 100115 10000 65 100115 123 I 18 I 6 I 113 I 10000 65 100
1
SLSti008Zol99168SLSt’008069til08SL8t7008069bl08SL8bOEL069tiISL
SL8VOWJLL9Z199
09SEoi79S9szl09
09SCoi79S9sZI09
09SEOsbS9sZI9s
09n09ESssLti
09SE09sSCSl:;Lb
+SEP9ESt’b801L~
S’i08ZStv01Zv09SE08ZSv$’01Zv09SE08ZSt’b01Zti
(lx)I(Iz)(oz)I(61)I(81)](Ll) ~—.(91)
AjXalgq~2IIII
dz!ii42ids dV3l—Xoil3NI.MnJ.s
091LSiOLIZb1000SIIOOSOII00001Ir-1m--l--l-l009
=/
!
09u8!sap
ZsS9LEOWEI0S6088jOOLLSti00s
09s,Jam]3eJnuewJadsvS9LEOo[zI0S80Z80s9ZEtiOsb
SsI:{09SE001111008OSLI0099(WOm
SsZvSsOEOOEO1OEL0690ss’18E0ss
0sOLS1OvzS9b9E8t7Sz016S8S08S00s9SE00E
0sS9]0108ZOst9E8t7SzSE8S6bSSEOsbOsfOszSvS9I01082Ot’cZEZPIZzSZL09t78tEI00PIZ(5ZOoz
.ONIS
m
IS 14846:2000
r ~OF DOOR & ~ OF BODY&DOOR FACE RING BODY SEAT RING~
.—
L Q OF BODY & ‘t OF DOOR &BODY SEAT RING DOOR FACE RING
NEW SEAT WORN SEAT
FIG. 2A TYPICAL SKETCH OF WEAR TRAVEL OF WEDGE
r-hEl 7
A
-i
D-J uD
FIG. 2B DIMENSIONSBODY SEAT AND WEDGE FACING RINGS
6
IS 14846:2000
Table 3A Flanges of Sluice Valves
(Clause 7.3)
All dimensions in millimetres.
I L---c --lI
sl Particulars Dimensions forNo. Nominal Size
T %50 65
1.Outside diameter (D) 165
+1.5185
+1.5-1.0 -1.0
2,Thickness of flange
+2.0 +2.0‘ 65 -0.0 16 -0.0
3. Diameter of bolt circle (C) 125tl.O 145*1.O
4. Number of bolts (Equally 4 4spaced off centre)
5. Diameter of bolt boles (d) 19 19
6. Diameter of bolts 16 16
Table 4 Dimensions of Body, Seat and WedgeFacing Rings
(Clause 7.4)
All dimensions in millimetres.
ValveSize
50
65
80
100
125
L50
200
250
300
350
400
450
500
600
700
750
800
900
1000
1 100
1200
A
78
89
9
9
11
11
13
13
1313
15
16
1919
22
24
27
30
30
B
10
11
1213
14
1416
17
19
19
1919
22
2428
28
32
36
4044
44
c
33
33
4
44
4
5
55
56
67
7
8
9
10
11
II
D
56
67
7
78
9
10
10
10
10
11
1214
14
16
18
20
22
22
7.5 Guides and Lugs
The guides and the lugs shall be provided to guide thewedge through its full travel. It shall be optional forthe manufacturer to provide guides on the wedge andlugs on the body or vice-versa. Where sluice ~alvesare intended to be used in a horizontal position andwhere so desired by the purchaser the lugs and guidesshall be provided with channel and shoe arrangementas per material specification in Table 1. Wherever thechannel and shoe arrangement is provided on guidesand lugs, the same shall be secured by non-protrudingrigid rivets of non-ferrous metals. The thickness ofthe channel and shoe liner shall be minimum 5 mmfor sizes of valves 450 mm and above. The maximumclearance between the guides and lugs with or withoutchannel and shoe arrangement shall be as givenin 7.5.1.
7.5.1 The clearance between lugs and guides fordifferent sizes of sluice valves shall be as given below:
Valve Size Maximum Total
(mm) Clearance (mmj50 to 300 3
350 to 450 4500 to 600 5700 to 1200 6
7.6 Facing or Seat Rings
The dimensions of the wedge facing rings and bodyseat rings shall be as specified in Table 4 read inconjunction with Fig. 2B.
7.7 Stems and Wedge Nuts
7.7.1 The major dimensions of stems and wedge nutsshall be in accordance with Tables 2,3 and 4 and readin conjunction with Fig. 1A, lB, lC, 2A, 2B, 3A, 3B,4,5 and 6.
7.7.2 Stems shall have machine-cut single start squareor trapezoidal threads of such lengths that the wedgescan be raised to a position so as to ensure fuIl flowpassage through the valve.
7.7.3 The clearance between the wedge net housinglugs on the wedge and the inside surface of the valvebody shall be adequate to insert the wedge net rnto thewedge lug recess either in the direction of water flowor in perpendicular direction when the wedge is inclosed position.
7.7.4 The stem of all valves shall be so screwed as toclose the valve when the cap, hand wheel or crankhandle is rotated in clockwise direction (However,counter clockwise rotation of stem for valve closure ispermitted subject to agreement between the purchaserand the manufacturer). Stems required for hand wheelmounting shall be tapped on top to suit setscrew.
-..—
7
IS 14846:2000
7.8 Bolts and Nuts
Bolts andnuts shall conform to IS 1363 and IS 4218
(Part 5). Tee headed bolts may also be used wherenecessary.
7.9 Height of Valve
The heights of valves shall conform to those given inTables 2 and 3 read in conjunction with Fig 1A, lBand lC.
7.10 Gears
Gears if provided, shall be of suilable design (see IS2535) and workmanship, so as to ensure satisfactoryworking of sluice valve. Gear ratio shall be workedout keeping in view the maximum stem torque, handwheel diameter and hand wheel effort as specified in7.11. The material for different components of gearshall conform to the requirements given in Table 1.
7.11 Hand Wheel
Hand wheel material shall be as per Table 1 and shallhave on the upper side of the rim the words OPENand SHUT with direction arrows as shown in Fig. 3Aand 3B. The hand wheel shall be secured by a set-screw. A steel washer to cover the square hole in theboss shall be fixed between the head of the setscrewand the bms of the hand wheel. The rim of the handwheel may be smooth or serrated and the spokes maybe curved or straight. The size of hand wheel for eachsize of valve shall be as specified in Tables 2 and 3.The total hand wheel effort shall not exceed 80 N atthe periphery of the hand wheel on opening/closingof valve.
\
+ .—. —. -—— - )-
1
Fm. 3B FABRICATED HANDWHEEL
Tables 2 and 3 (see Fig. 4) and shall be secu~ed bysetscrew.
7.12 Valve Caps
The stem of sluice valve operated by a removable keyshall be provided with caps of dimensions as given in
VALVESPINDLE
+
I
FIG, 4 VALVE CAP
7.13 Stuffhg Box
The minimum inside dimensions of stuffing box shallbe in accordance with Tables 2 and 3 read inconjunction with Fig. 5.
7.14 By Pass Arrangements
1,1
TAPER 1 IN 20>
TAPER 1 IN 20
+3
~T\/l- ,’/,1-SET SCREVV 1, ,1
df
FIG. 3A CAST HANDWHEELSluice valves may be provided with by passarrangements, if required by the purchaser. The
8I
1-@E
-i
IS 14846:2000
P--l
FIG. 5 STUFFINGBox
minimum size of by pass arrangements as required bya purchaser shall be as given below:
Nominal size of Sluice Size of By PassValve (mm) Arrangement (mm)
250 25300350400450500600700750800900
100011001200
254040505065808080
100100125125
FIG. 6 STEM WITH C-AP8 ACCESSORIES OR OPTIONAL FEATURES
Some of the accessories or optional features used with 10 TESTINGlarge sluice valves are given in Annex A for
10.1 Hydrostatic Testinformation.
9 COATING
9.1 All coatings shall be carried out after satisfactorytesting of the valves prior to despatch. All theunmachined ferrous surfaces of the valve (both insideand outside) shall be thoroughly clean, dry and shallbe free from rust and grease before painting. Allexposed machined ferrous surfaces shall be paintedwith one coat of alttminium red oxide primerconforming to IS 5660.
9.2 Two coats of black japan conforming to Type B ofIS 341 or paint conforming to IS 9862 or IS 2932shall be applied by brush or spray for exteriorapplication in colour as approved by the purchaser.
10.1.1 Each valve shall be subjected to hydrostatictests as described in Annex B to the test pressures andtest duration specified in Table 5 and Table 6respectively. The valves during the test shall not show
any sign of leakage.
Table 5 Test Pressure for Sluice Valves
PN Rating Test for Body/Seat Test PressureMPa (Gauge)
PN 1.0 Body 1.5Seat 1.0
PN 1.6 Body 2.4Seat 1.6
..-—
NOTE — A valve may be assembled without coating if a pur- 10.1.2 Valves intended, when in use, to be rigidly heldchaser specificalIy desires to inspect the assembled valve without at both ends in a pipeline either above or below ground,any coating, shall be subjected to ‘closed-end’ test (see B-l).
9
IS 14846:2000
Table 6 Test Duration for Sluice Valves
(Clause 10.1.1)
Valve Size Test for Body/Seat Test Durationmm tin
50 to I 200Body 5Seat 2
10.1.3 Valves intended, when in use, to be in a terminalposition rigidly held at one end only, shall be subjectedto ‘open-end’ test (see B-2).
10.2 Test for Stem
10.2.1 Flaw Detection Test for Stems
All stems, whether integrally forged or formed by anestablished technique shall be subjected to tests laiddown in 10.2.1.1 in accordance with samplingpt-ocedure outlined in Annex C. For 700 to 1200 mmvalves every stem shall be subjected to tests specifiedin 10.2.1.1.
10.2.1.1 Liquid penetrant test
After forming of a collar no stem shall show any signof flaw when subjected to liquid penetrant flawdetection test in accordance with IS 3658.
11 MARKING
11.1 The following information shall be cast on eachvalve body in raised letters.
a) The manufacturer’s name or trade-mark;
b) The nominal pressure of valve (PN 1.0 orPN 1.6);
c) Size of valve (mm);
d) Heat number of cast;
e) Year of manufacture;
In addition each valve shall bear conspi-
f)
g)
cuously upon it prior to despatch;
Serial number in punch, on top of flanges;and
Where a valve has been tested for only open-end test, it should be marked ‘O’ distinctlyand permanently on flanges adjacent to se-rial number.
11.2 Each sluice valve may also be marked with theStandard Mark.
11.2.1 The use of Standard Mark is governed by theprovision of the Bureau of Indian Standards Act, 1986and the Rules and Regulations made thereunder.Details of conditions under which a licence for theuse of the Standard Mark may be granted tomanufacturers or producers maybe obtained from theBureau of Indian Standards.
12 INFORMATION TO BE SUPPLIED WITHENQUIRY OR ORDER
The purchaser shall supply the information given atAnnex D along with his enquiry or order.
13 PACKING AND STORAGR
A recommended procedure for packing and storage isgiven below:
a)
b)
Packing — All valves shall be supplied withthe wedge closed. Bright parts shall be pro-tected against rust. Valves of small diametermay be packed in wooden cases and be suit-ably protected against damage. Parts liableto injury in transit shall be wrapped withwood-wool or similar material as a protec-tion. Hand wheels of valves forwarded looseshall be removed before despatch.
Storage — Valves shall be stored in roofedstores away from dirt.
10
IS 14846:2000
ANNEX A
(Clause 8)
ACCESSORIES OR OPTIONAL FEATURES FOR SLUICE VALVES
A-1 ACCESSORIES OR OPTIONAL FEATURES
A-1.l Accessories used, where required, with largesluice valves are given in A-1.l.l to A-1.1.15 anddetails of these should be furnished by themanufacturer where so desired by the purchaser.
A-1.l.l Locking Arrangement for Hand Wheel
A-1.1.2 Valve Gate Position indicator
They shall have two positions marked at the shut endof the scale, first one corresponding to the position ofthe gate tangential to the bore of the seating and thesecond position below the first, corresponding to theposition of the gate as it sits on the seating after movinga further distance equal to the depth of the seating.
A-LL3 Anti-Friction Devices
Thrust bearing of ball or similar type for stem collars.
A-1.1.4 Valve Headstock for Manual Operation
Through extended Stem with a view to facilitateoperation or when operation point is exactly over theextended Stem.
A-1.1.5 Gunmetal scour or cast iron cleaning door at
the bottom of the sluice valve body.
A-1.1.6 By-Pass Arrangement Valve
Full way gate valve may conform to IS 778 and sluicevalve where used, may conform to this standard.
A-LL7 Power Drive
Hydraulic, pneumatic or electric
A-1.1.8 Easing Screw
A-LL9 Air
Release plug
A-LI.10 Drain Plug
A-1.1.11 Channel and Shoe Arrangement
A-1.1.12 Gearing Arrangement
Spur, worm or bevel
A-1.1.13 Chain and Wheel Arrangement
A-1.1.14 Riveted Seat Rings in the Body
A-1.1.15 Pipe flanges drilling and dimensions otherthan IS 1538.
ANNEX B
(Clause 10.1.1)
TESTING OF SLUICE VALVES
B-1 CLOSED-END TEST
B-1.l Each valve shall be tested with the spindle invertical position, unless otherwise specified by thepurchaser, The testing machine, which may be eitherof hydraulic or mechanical type, shall exert adequateforce to compress the flexible material on either sidewithout exerting an undue load on the valve body,
B-1.2 Each valve held in vertical position shall besubjected to three hydrostatic tests. The first testshall be made with the wedge open and the pressureapplied for a period of minimum 5 minutes to thewhole body of the valve after releasing air throughthe gland. The second and third tests shall be madeto determine the water tightness of the faces withthe wedge closed. After the first test, the bodypressure shatl be reduced to working pressure and
the wedge shall be closed so that the bonnet remainsfilled with water. The second test shall be conductedwith the pressure (see 10.1.1) applied to the one faceand the third test with the pressure applied to theother face of the wedge. Under this condition, thevalve seating on the down-stream side shall bewatertight for a period of 2 minutes. During theperiod of above test, the pressure gauge reading shallnot fall below the test pressure.
B-1.3 A typical arrangement for closed-end test forsluice valves is shown in Fig. 7. The first testis donewith the wedge open and the pressure applied to thewhole body of the valve. The second test is made asshown by applying pressure from side 1’hydraulically,the third test is done applying pressure from theside X.
11
IS 14846:2000
“R T -J’-p=::EPRESSURE
GUAGE
.
& ~, / ,n-PRESSURE
PUMP
STOP VALVE —r
SUMPOR NON RETURN VALVE
:y&J..................
FIG. 7 TYPICALVALVETESTINGARRANGEMENTFOR CLOSED-END TEST
B-2 OPEN-END TEST
B-2.1 Each valve held in vertical position shall besubjected to three separate hydrostatic tests, The firsttest shall be made when the wedge is open and the
pressure applied to whole body of the valve afterreleasing air through the gland and for this test onlyuse of the-testing machine for closed end testing shallbe permissible. The second and third tests shall bemade to determine the water-tightness of the faces withLhewedge closed and the valve fixed at one end only.AIler the test, the wedge shall be closed so that thebonnet remains filled with wa(er. The second test shallbe conducted with the pressure (.~ee10.1.1) applied tothe one face and the third test with the pressure appliedto [he other face of the wedge. Under this condition,the valve seating on the down-stream side shall bewo[ertight for a period of 2 minutes, During the period
of above test, the pressure gauge reading shall-not fallbelow the test pressure.
B-2.2 A typical arrangement for open-end of sluicevalve is shown in Fig. 8. The first test is conductedwhen the gate is open as in the case of closed-end test,the second test is conducted by applying the pressurefrom the side Y, the third is performed by reversingvalve and applying pressure from the side X.
NOTE — Any valve that has been tested only by ihe closed-endtests and which, during the testing of a main or part of main afterlaying, occupies a terminal position on the main, should have itsexposed end blanked off and its wedge in the open position. Anyvalve that has been tested by the open-end tests should be simi-larly treated if the test pressure applied to the main exceeds themaximum working pressure. In either case any precaution neces-sary to resist hydraulic thrust on the valves by strutting or other-wise should be taken.
. ..—*
Is 14846:2000
+ rp,=s..,.u.=
STOP VALVE OR NON RETURN VALVE~
FIG. 8 TYPICAL VALVE TESTING ARRANGE
ANNEX C
(Clause 10.2.
T--PRESSURE PUMP
>
SUMP
....:.:.:.::. .:....... ..............~........+-:-:+:=.-:-:
IENTFOROPEN-ENDTEST
)
SAMPLING OF F(3RGED STEMS FOR FLAW DETECTION TEST
C-1 LOT
C-1.l All the forged stems of same size fromthe samemanufacturer, produced from the same batch of brassor stainless steel, shall be grouped together toconstitute a lot.
C-1.2 Each lot as defined in C-1.1, shall be takenseparately for sampling and testing before it is acceptedfor utilization in producing of valves. For this purpose,the number of samples depending on the size of thelot shall be drawn from the lot strictly at random.The number of samples from a lot shall be as givenin C-2. For ensuring the randomness of sampling,guidance may be taken from IS 4905.
C-2 SCA-LE OF SAMPLING
The number of sample stems to be selected from a lotshall be as given below:
No. of Stems in No. of Stems inthe Lot the Sample
Up to 8 All9 to 25 8
26 to 50 1351 to 100 20
101 to 300 32301 and over 50
C-3 CRITERIA FOR CONFORMITY
C-3.1 All the sample stems selected from the lot inaccordance with C-12, shall be subjected to the flawdetection test. The lot shall be accepted only when all thesample stems are found to pass in the flaw &tection test.
C-3.2 In case, if any one or more of the sample stemsfailing in the flaw detection test, all the stems in thelot shall be subjected to flaw detection test beforeacceptance and only those which are found to besatisfactory, shall be used in the production of valves.
13
-
IS 14846:2000
ANNEX D
(Clause 12)
INFORMATION TO BE SUPPLIED WITH THE ENQUIRY AND ORDER
D-1 The following information shall be supplied by h)the purchaser along with the enquiry and order:
a)
b)
c)
d)
e)
o
g)
Nominal pressure of valve required;
Size of valve required;”
Whether hand wheel or cap is required;
Whether hand wheels are required with spe-cial finish;
Whether the water is specially corrosive, andif so details to be given;
IS No.
28:1985
Whether valves are for use in pipeline or inunsupported or terminal positions;
Tests required (whether ‘closed-end’ or‘open-end’);
210:318:
320:
993981
980
341:1973
638:1979
778:1984
1030:1989
1363 (Part 1) :1992
j)
k)
m)
n)
P)
q)r)
s)
Whether additional test, other than thosespecified are required;
Whether contrary to the specification, coun-ter clockwise rotation for closing is required;
Nature of operation — Vertical, horizontalor inclined;
Flanges / Flange dimensions specific, if any;
Whether tail pieces or adaptors are requiredto suit special types or for proprietary or otherjoints;
Type of power operation required, if any;
Type of gear required;
Thrust bearings, if required on stem collar;and
By pass arrangement, if required.
ANNEX E
(Clause 2)
LIST OF REFERRED INDIAN STANDARDS
Title
Phosphor bronze ingots and castings(fourth revision)
Grey iron castings (fourth revision)Leaded tin bronze ingots andcastings (second revision)High tensile brass rods and sections
(other than forging stock) (secondrevision)
Black japan, Type A, B and C (/irst
revision)
Sheet rubber jointing and rubber in-sertion jointing (second revision)Copper alloy gate, globe and checkvalves for water works purposes(fourth revision)Carbon steel castings for generalengineering purposes ~ourrh revi-sion)
Hexagon head bolts, screws andnuts of product grade C : Part 1Hexagon head bolts (third revision)
IS No.
1363 (Part 3)1992
1538:1993
1570 (Part 3)1979
1865:1991
2062:1992
2535:1978
2712:1979
2932:1993
Title
Hexagon head bcdts, screws andnuts of product grade C : Part 3Hexagon nuts (size range M5 toM64) (third revision)Cast iron fittings for pressure pipesfor water gas and sewage (third re-vision)Schedules for wrought steels: Part 3Carbon and carbon manganese freecutting steels @rst revision)Iron castings with spheroidal ornodular graphite (third revision)Steel for general structural purposes(fourth revision)Basic rack and modules of cylindri-cal gears for general engineering andheavy engineering (second revision)Compressed asbestos fibre jointing(second revision)Enamel, synthetic, exterior (a) under-coating (b) finishing (secondrevision)
14
IS 14846-:2000●
IS No.
3444:1987
3658:1981
4218 (Part 5) :1979
4687:1995
4854 (Part 1) :1969
4905:19685414:1995
Title
Corrosion resistant alloy steel andnickel base castings for generalapplication (.secomi revision)Codeofpracticefor Iiquidpenetrantflaw detection (jht revision)ISO Metric screw threads: Part 5Tolerances @-.rr revision)Gasket and packing — Glandpacking asbestos (second revision)Glossary of terms for valves andtheir parts : Part 1 Screw down stopcheck and gate valve and their partsMethods for random samplingGasket and packing — Glandpacking, jute and hemp (firstrevision)
1S No.
5660:1970
6603:2000
6912:1985
7008 (Part 3) :1988
7008 (Part 4) :1988
9862:1981
Title
Ready mixed paint, brushing,aluminium — Red oxide primerStainless steels bars and flats @rstrevision)Copper and copper alloy forgingstock and forgings (first revision)ISO Metric trapezoidal screwthreads : Part 3 Basic dimensions(/h revision)1S0 Metric trapezoidal screwthreads : Part 4 Tolerances (first
revision)Ready mixed paint, brushing,bituminous, black, lead-free, acid,alkali, water and chlorine resisting
15
IS 14846:2000
ANNEX F
(Foreword)
COMMITTEE COMPOSITION
Sanitary Appliances and Water Fittings Sectional Committee, CED 3
ChairmanSHRIS. K. CHHABRA
Members
SHN VIDUR BHASKAR
HYDRAULICENGINEERDEPUTYHYWCWLICENGINEER(Alternate)
SHRID. P.SINGHSHRIV.K.SETM(FIELDOFFICER)(Alternate)
SHRIM. P.JAIPURIASHRIS. A. KHAN(Alfernafe)
AIIVISOR(PH ENGG)DYADVISOR(PH ENGG)(Ahernare)
St [RISURIX.HKUMARSHARMASNRIAJAYSINGH(Alternate)
DRA. K. GUnADRS. K. NAYAK
DRS. C. SHIT(Alternate)ADVISOR(P.H. ENGG)
DY AOVISOR(P.H. ENGG)(Alfemafe)
SSW ( NDZ -I)
SOW (N DZ-1) (Afterna/e)
CHIEFENGINEERSHIUM. GANGARAJU
SHRIR. P.SINGH(A/temare)
SHRIL. N. KAPDDRSHRIG. RABINDRANATHRAO
SHRIS. SIVAKUMAR(Alternafe)
SHRIL, D. SHARMASHRIS, K. KAILA(Alfernare)
SHRIJ. R. AGGARWALSHRISANJAYAOOARWAL(Alternate)
SHRIR. K.SOMANYSHRJSANDIPSOMANY(Alternate)
SHRIK.LAKSHMINARAMANASHRIA. SHARIFF(Akemate)
SHUIK, K. BHAUACHARYYASHRIS. SAHA(Alternate)
SHRIV.M, AGGARWALSHRIS. K. NEOCI
SHRiA. K.SENGUPTA(Akwae)
SHRIV.K.JAINTEc’tlMEMBER
CHIEFENGINEER(PS&G) (Alternate)SHRIR. D. KULKARNI
SHRIS, V,JAOAV(Alternate)
SHRIH~NIANT13ERISHRIH. K, ARORA(Ahernare)
CHIEFENGINEER(RURAL)SUPERINTENDINGENGINEER(Alfcvnate)
SHRIJ,P.S. JASSSHRIARUNKANTIBISWAS
SHRID. K, KANUNGO
SHRIR. KAPDOR(Alternate)
CHIEFENGINEER(WEST)
SHRIV. K. SINHA
SHRIW. U. KHAN (Alternate)
RepresentingDelhi Jal Board, New Delhi
BhaakarRefractories&Stoneware Pipes Pvt Ltd, FaridabadBrihanmumbaiMunicipafCorporation, Mumbai
BuildingMateriaIsandTedsrrologypromotion Council, New Delhi
Capstan Meters (India) Ltd, Jaipur
Central PubticHerdthand EnvironmentalEngineer’sOrganization, New Delhi
Central Building ResearchInstitute, Rmrkee
Central Glass &Ceramic Research Institute (CSIR), CatcuttaCentral Instituteof PlasticEngineeringandTechnology,Chennai
Central Public Heatrhand EnvironmentalEngineer’sOrganization, New Delhi
Centril PubticWorks Department,New Delhi
Delhi DevelopmentAuthority,New DelhiDirectorateGeneral of Suppliesand D@osals, NewDelhi
Delhi Jal Board, New DelhiEID-Parry (India) Ltd, Ranipet
Engineer-in-Chief’sBranch,New Delhi
GoverdhanDas PA(Calcutta),Calcutta
HindustanSanharywareIndustriesLtd,Bahadurgarh
HindustanShipyardLtd,Vkakapatnam
IndianVatvePvtLtd,Naaik
Indian WaterWorksAssociation, New DelhiInstitutionof P H Engineers India, Calcutta
Johnson Pedder Pvt Ltd. MumbaiKerala WaterAuthority,Thituvananthapuram
KirloskarBrothers Ltd. Pune
Leader EngineeringWorka,Jathrndhar
MaharashtraWS & Sewerage Board, Mumbai
Metro Sanitation Pvt Ltd, New DelhiNEERI, CatcuttaNational TestHouse, Calcutta
NorthernRailway,New DelhiSchlumbergerIndustries(India) Ltd, Haryrma
(COnlinuedm page 17)
16
IS 14846:2000
(Continued from page 16)
Members
SUPERIN’MNDINGENGINEERTAC (Q/C)EXECUUWEENGINEERTAC (Akrrrare)
Sw S. SU~DARAMSHk!lS. S. ScrHl,
Director (Civ Engg)
Representing
Uttar PradeshJrdNigam, Lucknow
VetmtexLimited, HyderabadDirector General, BIS (Ex-oficio Member)
Valves and Gates Subcommittee, CED 3:5
Convener
HYDRAULICENGINEER Brihanmumbai Mahanagar Palika, MumbaiMembers
DY CHIEF Building Material and TechnologyPromotion Council, New DelhiSHRI t? K. JOSHI BSJ Shau Manufacturer (India), Nagpur
DIRECTOR(A[ternare)
CHIEFENGINEER(MAINTENANCE) BangaloreWaterSupply&Sewerage Board, BangaloteDFPUTYCHmFENGiNEER(CCS~MONSERVICES)(Alfemate)
WORKSMANAGER
DEPUTYHYDRAULICENGINEER
Ssw (s&s)
ASSNTAfWDUWCTOR
ASSISTANTINSPECTJONOFFICER(Alternate)
CHiEFENGINEER(C-1)
SUPERINTENDINGENGINEER(W-111) (Alternate)
GENERALMANAGER
SHRIRAMACHANDRAH.THAKKAR
SHRINANDKUMARH.THAKKAR(Alternate)
SHRIJ. R. AGGARWAL
SHRISANJAYAGGARWAL(Alternate)
SHRIK. K, BHATTACHARYYA
SNRIS. SAHA(Al[ernule)
Stuu S.J. PATEL
SHRIPRATIKPATEL(Alternate)
CHtEFENGINEER
‘CECHNICALDIRECTOR(Alternate)
SHIrI R, D, KULKARNI
SHRJS. V. JADAV(Alrernare)
SHRiD. K, SEHGAL
SHiUB. B. SIKKA(Alremafe)
SHRIA. K. SEN
SHRIS. M. TANHANE(Altemare)
SHRIR, K. GUPTA
SHRISANJAYMAHISARIA(Alremats?)
SHWDEEPAKBELAFWRE
SHRIR. S. DHUMAL
SHRIO. P. WADHWA(Alternate)
SUPERINTENDINGENGINEER(MM)EXECUTIVEENGINEER(MM) (Alternate)
CHIEFENGINEER
SUPERNTENOINCENGINEER(Ahemare)
SHRIJ. D. CRUZ
Bombay Metals and Alloys ManufacturingCo Pvt Ltd, MumbaiBrihanmumbaiMaharragarPalika, MumbaiCentraJPublicWorksDepartment,New DelhiDirectorateGeneral of Supplies and Dkposals, New Delhi
Delhi Jal Board, NewDelhi
Fouress Engg Pvt Ltd, BangaloteGeeta Valvesand EngineeringPvt Ltd, Vadodara
Goverdhan DrrsPA(Calcutta), Calcutta
Indian ValvePvt Ltd, Nasik
Jash Engg Pvt Ltd, Indore
KeraIaWaterAuthority,TMmvanamhapuram
Klrloskar Brothers Ltd, Pune
Leader ValvesLtd. Jrdlundhar
NationalEnvironmentalEngineeringReseareh Institute,Nagpur
Oriental Castings Pvt Ltd, Sonapet
R&D Multiples Metalcast Pvt Ltd, MumbaiSam VafvesPvt Ltd, Jallundhar
TWADBoard, Chennai
U.P. Jal Nigam, Lucknow
In personat capacity (B-58A, Gangotri Enclave,Alakrtan@ New Delhi 110019)
——
17
Bureau of Indian Standards
BIS is a statutory institution established under the Bureau o$ Indian Standards Act, 1986 to promoteharmonious development of the activities of standardization, marking and quality certification of goodsand attending to connected matters in the country.
Copyright
BIS has the copyright of all its publications. No part. of these publications may be reproduced in any formwithout the prior permission in writing of BIS. This does not preclude the free use, in the course ofimpleme~ing the standard, of necessary details, such as symbols and sizes, type or grade designations.Enquiries relating to copyright be addressed to the Director (Publications), BIS.
Review of Indian Standards
Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewedperiodically; a standard along with amendments is reaffirmed when such review indicates that no changes areneeded; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standardsshould ascertain that they are in possession of the latest amendments or edition by re~erring to the latest issue of‘BIS Catalogue’ and ‘Standards: Monthly Additions’.
This Indian Standard has been developed from Doc : No. CED 3 (5411).
Amendments Issued Since Publication
Amend No. Date of Issue Text Affected
BUREAU OF INDIAN STANDARDS
Headquarters :
Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002 Telegrams : ManaksansthaTelephones :3230131,3233375,3239402 (Common to all offices)
Regional Offices : Telephorie
Central :
Eastern :
Northern :
Southern :
Western :
Branches :
Manak Bhavan, 9 Bahadur Shah Zafar MargNEW DELHI 110002
1/14 C. I. T. Scheme VII M, V. I. P. Road, KankurgachiCALCUTTA 700054
SCO 335-336, Sector 34-A, CHANDIGARH 160022
C. I. T. Campus, IV Cross Road, CHENNAI 600113
Manakalaya, E9 MIDC, Marol, Andheri (East)MUMBAI 400093
{
32376173233841
{
3378499,33785613378626,3379120
{
603843602025
{
235021-6,23504422351519,2352315
{
8329295,83278588327891,8327892
AHMADABAD. BANGALORE. BHOPAL. BHUBANESHWAR. COIMBATORE.FARIDABAD. GHAZIABAD. GUWAHATI. HYDERABAD. JAIPUR. KANPUR.LUCKNOW. NAGPUR. PATNA. PUNE. RAJKOT. THIRUVANANTHAPURAM.
Printed at : Frahhat Offset Press, Ne; Delhi-2
.
.
AMENDMENT NO.
TO
IS 14846:2000 SLUICE VALVE FOR
1 JULY 2001
WATER WORKS PURPOSES(50 TO 1200 mm SIZE ) — SPECIFICATION
[Page 2, Table 1, S1 No. (i), co! 8] — Substitute ‘500/7’ for ‘260-300/12 or 500/2’ against IS 1865 and add‘230-450W’ against IS 1030.
[Page 2, Table 1, S1 No. (iii), COI5] — Substitute the existing by ‘12Cr13/04Crl 8Ni10/04crl 7Ni12M02’.
(Page 4, Table 2) — Substitute the existing Table 2 with the Table 2 appearing .on page 2.
(Page 5, Table 3) — Substitute the existing Table 3 with the Table 3 appearing on page 3.
(Page 7, Clause 7.7.3, line 1 and 3) — Substitute ‘nut’ for ‘net’.
+2.0 , +2.0 ,(Page 7, Table 3A, S1 No. 2,CO13) — Substitute ‘16 ~.. for ‘ 165
-0.0
(Page 7, Table 4) — Add ‘Min’ below A, B, C and D.
(Page 8, Fig. 4) — Substitute the existing Fig. 4 by the following:
I-;-l
TAPER 1 N 20>
TAPER 1 IN 20
SET SCREW
I
VALVE SPINDLE-,
FIG 4 VALVE CAP
(Page 8, clause 7.14) — Insert the following at the end of the clause:
‘ Nominal Size of Sluice Size of By PassValve (m.rn) Arrangement (mm)
200 25
(Page 9, clause 9.1, lines 3 and 4) — Delete ‘(both inside and outside)’..
Price Group 2 1
Table 2 Dimensions of Sluice Valves fdr Nominal Pressure PN 1.0(Clauses 7.2.4,7.7.1,7.9,7.11, 7.12,7,13 and Fig. 1A, lB, 4 and 5)
All dimensionsin miilimetres.
N
NOTES1–PD Preferred dimensions (short body).2- ALT I Alternate I dimensions (long body).3- ALT H Alternate11dimensions.4-$ Dimensions given under Alternate 11will stand deleted with effect from 01 April 2005.5- ($$) As and when 1S0 stipulates, these dimensions will be notified.6_* Packing size represents diairreter in case of round and side in case of square shaped packings.
Tolerances on Length ‘A’ other TolerancesUp to and including 300 mm *2mm Tolerances on square, a and X * 0.5 mmAbove 300 and including 600 mm * 3 mm Tolerances on length of square, C *1.OmmAbove 600 and inchiding 800 mm * 4 mm Tolerances on size of hand wheel, D * 5.0 mmAbove 800 and inclrsdlng 1000 mm + 5 mm Tolerances on length of square ‘Y’ ● 0.5 mmAbove 1000 mm +6mm
,
Table 3 Dimensions of Sluice Valves for Nbminal Pressure PN 1.6
(Clauses 7.2.4,7.7.1,7.9,7.11, 7.12,7.13 and Fig. 1A, lB, 4 and 5)
All dimensions in millimetres.
‘0”“mI I I CA’ I
I I I
PD I ALT-I I ALT-11$i BMdx
(1) (2) (3) (4) (5) (6)
9 50 178 250 215 160—— !
ii) 65 190 270 230 215iii) 80 203 280 230 220iv) 100 229 300 255 250
v) 125 254 325 266 310vi) 150 267 350 280 330
vii) 200 292 400 318 460viii) 250 330 450 355 495
ix) 300 356 500 380 585
x) 350 381 550 690 730
xi) 400 406 600 750 800
xii) 450 432 650 820 850xiii) 500 457 700 880 930xiv) 600 508 %00 1000 I 050
NOTES
Overall square Length Dla Length fromHeight of of collar
square Stem
H a c Min L1 L2Mar(7) (8) (9) (lo) (11) (12)
365 15 30 22380 15 30 22425 15 30 22470 18 36 27485 18 36 27595 18 36 27
collar Dia Depth Inside *Packing No.Size
Depth Size of of LengthThick- Of of Dia Size of Hand
Bonom ofness collar Nut Pack- Wheel
SquareSquare
ing
t G K E Min F D x YMin Min Min
(13) (14) (15) (16) (17) (18) (19) (20) (21) (22)
30 42 10 4 45 280 35 6030 42 10 4 45 280 35 6030 42 10 4 45 280 35 6035 47 10 4 45 360 35 6035 47 10 5 55 360 35 60 >35 47 10 5 55 360 35 60
725 22 42 32 As per manufacturer’s 45 56 12 5 65 450 35 60835 25 48 36 design 50 60 12 5 65 640 35 60910 25 48 36 50 60 12 5 65 640 35 60
1030 30 55 42 55 66 12 6 77 640 48 751110 35 60 47 55 75 14 6 90 730 48 751210 37 65 52 60 80 14 6 90 800 48 751340 37 65 52 60 80 14 6 90 800 48 75
1 , , ! , ,
15001 42 I 70 57 60 89 16 6 102 I8OOI48]75
1-PD Preferred dwosions (short body).
2- ALT I Alternate 1 dnerrsions (long body).
3- ALT 11 Alternate II dmensimrs.
4-$ Dmensions given mrderAhemate 11will stand deleted with effect from 01 April2005.
5-* Packkig size represents diameter in ease of round and side in case of square shaped packings.
Tolerances on Length ‘A’ Other TolerancesUp to and including 300 mm +2mm Tolerances on squark, d and X * 0.5 mmAhove 300 and including 6@Omnr A3mm Tolerances on length of square, C * l.ommAhove 600 and inchsdksg800 mm +4mm Tolerances on sim of hand wheel, D * 5.0 mmAbove 800 and including 1000 mm ●5mm Tolerances on length of square ‘Y’ ● 0.5 mmAhove 1000 mm *6rnm
I