1.ALL WORK IS TO BE IN COMPLIANCE WITH ALL LOCAL, STATE AND ALL WORK IS TO BE IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES AND ORDINANCES. 2.ALL UNDERGROUND ELECTRICAL CONNECTIONS ARE TO BE MADE WITH ALL UNDERGROUND ELECTRICAL CONNECTIONS ARE TO BE MADE WITH 3-M WIRE CONNECTORS, DBY. 3.ALL REMOTE CONTROL VALVES ARE TO BE INSTALLED IN VALVE BOXES ALL REMOTE CONTROL VALVES ARE TO BE INSTALLED IN VALVE BOXES OF APPROPRIATE SIZE. 4.ALL CONTROL WIRING DOWNSTREAM OF THE CONTROLLER IS TO BE 14 ALL CONTROL WIRING DOWNSTREAM OF THE CONTROLLER IS TO BE 14 AWG, UL APPROVED FOR DIRECT BURY. 5.ALL ROTORS AND SPRAY POP-UPS SHALL BE INSTALLED ON SWING PIPE. ALL ROTORS AND SPRAY POP-UPS SHALL BE INSTALLED ON SWING PIPE. 6.ALL QCV SHALL BE INSTALLED ON 3-ELBOW PVC SWING JOINTS. ALL QCV SHALL BE INSTALLED ON 3-ELBOW PVC SWING JOINTS. 7.SYSTEM DESIGN BASED UPON 40 GPM @ 75 PSI. SYSTEM DESIGN BASED UPON 40 GPM @ 75 PSI. 8.ANY CHANGES IN AVAILABILITY OF SUPPLY SHOULD BE NOTED AND ANY CHANGES IN AVAILABILITY OF SUPPLY SHOULD BE NOTED AND MODIFICATIONS TO THE DESIGN SHOULD BE MADE. 9.CONTRACTOR TO VERIFY WATER PRESSURE AND AVAILABILITY PRIOR CONTRACTOR TO VERIFY WATER PRESSURE AND AVAILABILITY PRIOR TO INSTALLATION. 10.THE LOCATION OF ALL IRRIGATION IS DIAGRAMMATIC AND SUBJECT TO THE LOCATION OF ALL IRRIGATION IS DIAGRAMMATIC AND SUBJECT TO FIELD VERIFICATION. 11.ANY IRRIGATION PIPING SHOWN OUTSIDE OF CURBS FOR CLARITY ONLY. ANY IRRIGATION PIPING SHOWN OUTSIDE OF CURBS FOR CLARITY ONLY. 12.120V. TO CONTROLLER AND COPPER STUB, BY OTHER THAN IRRIGATION 120V. TO CONTROLLER AND COPPER STUB, BY OTHER THAN IRRIGATION CONTRACTOR. 13.A BOOSTER PUMP IS REQUIRED IF SYSTEM DOES NOT MEET THE DESIGN A BOOSTER PUMP IS REQUIRED IF SYSTEM DOES NOT MEET THE DESIGN PRESSURE. 14.THE CONTRACTOR IS RESPONSIBLE FOR THEIR OWN MATERIAL TAKE OFF.THE CONTRACTOR IS RESPONSIBLE FOR THEIR OWN MATERIAL TAKE OFF.
AutoCAD SHX Text
1" = 30'-0"
AutoCAD SHX Text
124523
AutoCAD SHX Text
IR-1
AutoCAD SHX Text
IRRIGATION PLAN
AutoCAD SHX Text
Designed By:
AutoCAD SHX Text
SYMBOL MANUFACTURER/MODELQTY SYMBOL MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY QTY Hunter MP1000 PROS-04-PRS40-CV48 Hunter MP1000 PROS-04-PRS40-CV48 48 Hunter MP2000 PROS-04-PRS40-CV10 Hunter MP2000 PROS-04-PRS40-CV10 10 Hunter MP3000 PROS-04-PRS40-CV18 Hunter MP3000 PROS-04-PRS40-CV18 18 Hunter MP Corner PROS-04-PRS40-CV2 Hunter MP Corner PROS-04-PRS40-CV2 2 Hunter MP Strip PROS-04-PRS40-CV42 Hunter MP Strip PROS-04-PRS40-CV42 42 SYMBOL MANUFACTURER/MODELQTY SYMBOL MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY QTY Hunter PGP-ADJ14 Hunter PGP-ADJ14 14 Hunter PGP-ADJ51 Hunter PGP-ADJ51 51 Hunter PGP-ADJ19 Hunter PGP-ADJ19 19 Hunter PGP-ADJ-LA13 Hunter PGP-ADJ-LA13 13 SYMBOL MANUFACTURER/MODELQTY SYMBOL MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY QTY Netafim BD in Underhill A-DD24 Drip Stake 24" (x3)47 Netafim BD in Underhill A-DD24 Drip Stake 24" (x3)47 47 Area to Receive Dripline Area to Receive Dripline Netafim TLCV-06-18 (18)2,069 s.f. Netafim TLCV-06-18 (18)2,069 s.f. 2,069 s.f. SYMBOL MANUFACTURER/MODELQTY SYMBOL MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY QTY Hunter HQ-44LRC 1"2 Hunter HQ-44LRC 1"2 2 Shut Off Valve - Mainline Sized1 Shut Off Valve - Mainline Sized1 1 Febco 825Y 1-1/2"1 Febco 825Y 1-1/2"1 1 Baseline BL-1000XS1 Baseline BL-1000XS1 1 Baseline BL-WTS100KIT1 Baseline BL-WTS100KIT1 1 Point of Connection1 Point of Connection1 1 Irrigation Mainline: PVC Schedule 40 2"691.4 l.f. Irrigation Mainline: PVC Schedule 40 2"691.4 l.f. 691.4 l.f. Pipe Sleeve: PVC Schedule 40 2"197.1 l.f. Pipe Sleeve: PVC Schedule 40 2"197.1 l.f. 197.1 l.f. Pipe Sleeve: PVC Schedule 40 4"98.0 l.f. Pipe Sleeve: PVC Schedule 40 4"98.0 l.f. 98.0 l.f. Pipe Sleeve: PVC Schedule 40 6"103.3 l.f. Pipe Sleeve: PVC Schedule 40 6"103.3 l.f. 103.3 l.f.
1.ALL WORK IS TO BE IN COMPLIANCE WITH ALL LOCAL, STATE AND ALL WORK IS TO BE IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES AND ORDINANCES. 2.ALL UNDERGROUND ELECTRICAL CONNECTIONS ARE TO BE MADE WITH ALL UNDERGROUND ELECTRICAL CONNECTIONS ARE TO BE MADE WITH 3-M WIRE CONNECTORS, DBY. 3.ALL REMOTE CONTROL VALVES ARE TO BE INSTALLED IN VALVE BOXES ALL REMOTE CONTROL VALVES ARE TO BE INSTALLED IN VALVE BOXES OF APPROPRIATE SIZE. 4.ALL CONTROL WIRING DOWNSTREAM OF THE CONTROLLER IS TO BE 14 ALL CONTROL WIRING DOWNSTREAM OF THE CONTROLLER IS TO BE 14 AWG, UL APPROVED FOR DIRECT BURY. 5.ALL ROTORS AND SPRAY POP-UPS SHALL BE INSTALLED ON SWING PIPE. ALL ROTORS AND SPRAY POP-UPS SHALL BE INSTALLED ON SWING PIPE. 6.ALL QCV SHALL BE INSTALLED ON 3-ELBOW PVC SWING JOINTS. ALL QCV SHALL BE INSTALLED ON 3-ELBOW PVC SWING JOINTS. 7.SYSTEM DESIGN BASED UPON 40 GPM @ 75 PSI. SYSTEM DESIGN BASED UPON 40 GPM @ 75 PSI. 8.ANY CHANGES IN AVAILABILITY OF SUPPLY SHOULD BE NOTED AND ANY CHANGES IN AVAILABILITY OF SUPPLY SHOULD BE NOTED AND MODIFICATIONS TO THE DESIGN SHOULD BE MADE. 9.CONTRACTOR TO VERIFY WATER PRESSURE AND AVAILABILITY PRIOR CONTRACTOR TO VERIFY WATER PRESSURE AND AVAILABILITY PRIOR TO INSTALLATION. 10.THE LOCATION OF ALL IRRIGATION IS DIAGRAMMATIC AND SUBJECT TO THE LOCATION OF ALL IRRIGATION IS DIAGRAMMATIC AND SUBJECT TO FIELD VERIFICATION. 11.ANY IRRIGATION PIPING SHOWN OUTSIDE OF CURBS FOR CLARITY ONLY. ANY IRRIGATION PIPING SHOWN OUTSIDE OF CURBS FOR CLARITY ONLY. 12.120V. TO CONTROLLER AND COPPER STUB, BY OTHER THAN IRRIGATION 120V. TO CONTROLLER AND COPPER STUB, BY OTHER THAN IRRIGATION CONTRACTOR. 13.A BOOSTER PUMP IS REQUIRED IF SYSTEM DOES NOT MEET THE DESIGN A BOOSTER PUMP IS REQUIRED IF SYSTEM DOES NOT MEET THE DESIGN PRESSURE. 14.THE CONTRACTOR IS RESPONSIBLE FOR THEIR OWN MATERIAL TAKE OFF.THE CONTRACTOR IS RESPONSIBLE FOR THEIR OWN MATERIAL TAKE OFF.
AutoCAD SHX Text
1" = 30'-0"
AutoCAD SHX Text
124523
AutoCAD SHX Text
IR-2
AutoCAD SHX Text
IRRIGATION PLAN
AutoCAD SHX Text
Designed By:
AutoCAD SHX Text
SYMBOL MANUFACTURER/MODELQTY SYMBOL MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY QTY Hunter PGP-ADJ4 Hunter PGP-ADJ4 4 Hunter PGP-ADJ21 Hunter PGP-ADJ21 21 Hunter PGP-ADJ19 Hunter PGP-ADJ19 19 Hunter PGP-ADJ-LA6 Hunter PGP-ADJ-LA6 6 SYMBOL MANUFACTURER/MODELQTY SYMBOL MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY QTY Netafim BD in Underhill A-DD24 Drip Stake 24" (x3)47 Netafim BD in Underhill A-DD24 Drip Stake 24" (x3)47 47 Area to Receive Dripline Area to Receive Dripline Netafim TLCV-06-18 (18)7,616 s.f. Netafim TLCV-06-18 (18)7,616 s.f. 7,616 s.f. SYMBOL MANUFACTURER/MODELQTY SYMBOL MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY MANUFACTURER/MODELQTY QTY Hunter HQ-44LRC 1"2 Hunter HQ-44LRC 1"2 2 Shut Off Valve - Mainline Sized1 Shut Off Valve - Mainline Sized1 1 Febco 825Y 1-1/2"1 Febco 825Y 1-1/2"1 1 Baseline BL-1000XS1 Baseline BL-1000XS1 1 Baseline BL-WTS100KIT1 Baseline BL-WTS100KIT1 1 Point of Connection1 Point of Connection1 1 Irrigation Mainline: PVC Schedule 40 2"691.5 l.f. Irrigation Mainline: PVC Schedule 40 2"691.5 l.f. 691.5 l.f. Pipe Sleeve: PVC Schedule 40 2"127.3 l.f. Pipe Sleeve: PVC Schedule 40 2"127.3 l.f. 127.3 l.f. Pipe Sleeve: PVC Schedule 40 4"117.4 l.f. Pipe Sleeve: PVC Schedule 40 4"117.4 l.f. 117.4 l.f. Pipe Sleeve: PVC Schedule 40 6"53.5 l.f. Pipe Sleeve: PVC Schedule 40 6"53.5 l.f. 53.5 l.f.