Service ManualPhilips Domestic Appliances and Personal Care
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
Provapor inox new profi
HI 922
SAP coding HI 922
PRODUCT INFORMATION
Feataures : inox sole plate boiler capacity 1 litre length steam hose 1,9 metre length cord set 1,9 metre maximum steam output 60 gr/min
Voltage : 220-240 VoltFrequency : 50-60 Hz
Power consumptium : Boiler : 1200 Watt Pressure : 2,5 bar Iron : 800 Watt
4322 277 0012600/02PCS 101 361
Product meets the requirements regarding interference suppression on radio and television.
- After the product has been repaired, it should function properly and has to meet the safety requirements as laid down offi cially established at this moment.
! ServiceInformation ! Service
Information
! ServiceInformation
PCS 101 362
EXPLODED VIEW IRON
Screws : d x 1
A 3.0 x 27B 3.0 x 25C 3.0 x 19D 3.0 x 6E 4.0 x 12F 3.0 x 9G M4 x 24H 3.0 x 9I M4 x 12
DAP1102
5
1
15 8
44
2412
13
14
13
19
16
10
18
6
9X
4 3 21 11
17232220
2
7
2x
2x
B H
I
2xE
D
C
G
A
F
PARTS LIST IRON DISASSEMBLY ADVISE IRON
DIAL 1
RING 2
MICROSWITCH 3
LEVERMICROSWITCH 4
remove SCREW Aremove COVER MICROSWITCH 5lift MICROSWITCH 3unsolder WIRING
Pos Description Service Nummer
Insert dialDial ringMicroswitchLever microswitchCover microswitch
12345
9965 000 020854822 532 127724822 282 302399965 000 020864822 442 00787
Handle right + left partSwivel, colour blackSteam hose / electric cablePilot lightCork grip
6+789
1011
4822 310 109444822 325 101934822 530 103774822 134 100764822 498 10638
Clamping ringClamping ringSleeveConnecting bracket therm.Metal cover
1213141516
4822 492 710014822 532 127424822 325 101944822 402 106894822 442 00788
Insulating bracketSole plate + pos. 19ThermostatInsulating plateBracket + item 22 and 23
1718192021
4822 466 114734822 259 102344822 282 302384822 466 114744822 310 10945
Hose joint24 4822 526 10669
IRON
Steam-switch
Thermostat
p
Cutout
Cut out
TABLE UNIT
Steam-valve
IRON
PCS 101 363
ADJUSTMENT AND CONTROLS
Thermostat 19Thermostat ( 19 ) supplied as a spare part or fi tted to the sole plate ( 18 ) has already been adjusted by the supplier and secured by glue.To avoid disfunction of the iron , NEVER readjust the thermostat.
REPLACEHANDLE 6 + 7
remove SCREW Bremove SCREW Cremove SCREW Dremove SCREW E
D
CE
B
REPLACE SWIVEL 8
REPLACE HOSE 9
REPLACEPILOT LAMIP 10
disassemble HANDLE PARTS 6+7remove SCREW F 2 xremove CONNECTING WIRESremove CLAMP( S )
REPLACECORK GRIP 11
disassemble HANDLE PARTS 6+7remove SCREW Gremove SCREW H
REPLACE COVER 16
REPLACESOLE PLATE 18
REPLACETHERMOSTAT 19
REPLACEINSULATING PLATE 20
remove DIAL 1remove RING 2remove HANDLE PARTS 6+7remove HOSEremove SLEEVEremove CORK GRIPremove SCREW Iremove BRACKET 21turn conductor B through 180 degrees
remove PLATE 17
THERMOSTAT 19 ONLY
cut CONDUCTOR A at location Premove SCREW J
P
QB
A
D
NOTE :
For opening you need a Torx screwdriver 362 TR T20 x 100.
ASSEMBLYREQUIREMENTSTHERMOSTAT 19
Instead of metal conductor A, the new thermostat has a wire with AMP clamp.After fi xing screw J, connect the AMP clamp to tag Q.After assembling cover 16 ALWAYS turn conductor B through 180 degrees.
EXPLODED VIEW STAND
PCS 101 364
E
D
DAP1103
31
32
30
33
35
36
34
37
39
36
38
40
42
41
43
PARTS LIST + DISASSEMBLY ADVICE STAND
Pos Description Service Nummer
Stand rubber feetRubber feet above screwComplete traySafety valveRubber ring in fi lling hole
3031323334
9965 000 016929965 000 017029965 000 018619965 000 018629965 000 01866
CoverRubber feet boilerBoiler completeLocked insertBottom housing
3536373839
9965 000 018674822 462 719999965 000 018689965 000 017889965 000 01789
FilterSwitchElectro valveCordset Italian plugCordset Europe plug
40414243
9965 000 017909965 000 017914822 218 115619965 000 017929965 000 01793
GBR, FRA, DEU, NLD,ESP, PRT, ITA
DFU 4222 001 92450
OPEN THE STAND
D
Below rubber feetremove SCREW D (1 x)
E
E E
remove SCREW E (3 x)
remove LOCKED INSERT 38
NOTE:OPEN NOW THE STAND.DON’T WORRY IF THE SNAPS AT THE SIDE WILL BE BROKEN.THEY ARE ONLY FOR THE ASSEMBLY.THE STAND REMAINS CLOSE WITHOUT THESE SNAPS.
ADJUSTMENT AND CONTROLS
– To avoid leakage of the sealings and damage to the components in and on the boiler, NEVER clean the boiler with vinegar, a descaling agent or other chemicals.
– The boiler doesn’t contain serviceable parts.Never disassemble the boiler body and /or compo-nents on and in the boiler.
– ALWAYS REPLACE THE BOILER ( 37 ) WHEN:
* the mechanical safety valve ( 33 ) has been acti-vated.
* the boiler thermostat or hand - resettable safety thermostat are open, because the boiler has been subjected to too high temperatures.
* the electrovalve ( 42 ) fails or the sieve is soiled with scale.
– After the product has been repaired, it should func-tion properly and has to meet the safety require-ments as laid down and offi cially established at this moment.