TC-902/ 904/ 906/ 908
IInnffrraarreedd SSiimmuullttaanneeoouuss
IInntteerrpprreettaattiioonn SSyysstteemm
User Manual
8/2/2019 IR System User Manual
2/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
2
TABLE OF CONTENTS
Safety Instructions p3
General Description p4Interpreter Console p5
Infrared Transmitter p10
Infrared Radiator p12
Infrared Receiver p14
Interpreter Headset p18
Delegate Earphone -- p18
Receiver Lanyard p18
Receiver Carrycase p18
Radiator Bracket p19
Radiator Tripod p19
Interpreter Cable p19
Radiator Cable p19
Radiator Mounting p20
Configuration Diagram p21
System Connection p22
System Testing p22
Limited Warranty p23
8/2/2019 IR System User Manual
3/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
3
Important Safety Instructions
1. Follow all instructions.
2. Do not block any ventilation openings.
3. Do not place the apparatus on an unstable surface, near water or heat source.
4. Use only the power cord that comes with the apparatus. Use of another cord may result in fire
or electric shock.
5. Use only the type of power source indicated on the apparatus and always supply power directly
from a standard domestic electric outlet with the AC power cord that meets the relevant local
safety standards.
6. Connect all equipment to properly grounded power outlets. Avoid using outlets on the same
circuit as photocopiers or air control systems that regularly switch on and off.
7. Protect the power cord from being walked on or pinched.
8. Unplug the apparatus during lightning storms or when unused for long periods of time.
9. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the unit, the apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped.
8/2/2019 IR System User Manual
4/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
4
General Descript ion
GONSIN TC-902/904/906/908 infrared system is designed to offer simultaneous interpretation
and wireless audio distribution for up to 1, 3, 5 or 7 different languages plus the floor language
using the proven, state-of-the-art infrared light transmission technology.
As the central element of the system, the infrared transmitter interfaces with either analog or
digital discussion system, connects to the interpreter consoles and the infrared radiators which
transmit audio signals to wireless multi-channel receivers for the delegates to hear the language
of their choice via personal earphones.
The system operates in the higher 2 MHz to 6 MHz frequency band, immune to distortion from
hall lighting and free from outside radio frequency interference.
As infrared signals do not pass through walls and ceilings, the system is secure to use. Multiple
applications can run simultaneous in different rooms without interfering with one another.
The system complies with the relevant ISO, IEC, CE standards/requirements and is ideally suited
for use in business and government conferences, international conventions and other multilingual
applications.
Typical Applications
Convention centers Parliament chambers Courtrooms
Boardrooms City councils Classrooms
Auditoriums Theatres Churches
8/2/2019 IR System User Manual
5/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
5
II nn tt eerr pprr eett eerr CCoonnssoollee
Model No. TC-F06/16
Main Features:
Digitally-controlled unit for single interpreter.
Designed to comply with IEC60914/CE standards & requirements.
Handles simultaneous interpretation for 6/16 different languages.
Supports direct interpretation and relay interpretation.
Function keys with corresponding LED indicators.
LCD screen to display the following information:
1) Specific settings for the interpreter unit.
2) Incoming/outgoing language channel number.
3) All the occupied language channels.
4) The language channel occupied by the present unit.
5) Interpretation time from the beginning to the end.
3 incoming languages can be preset, with pre-select A/B/C keys.
FLOOR key can be pushed to return to the incoming floor/original channel setting.
Left/Right < > keys for incoming channel selection.
Left/Right < > keys for outgoing channel selection.
Two different types of microphone can be used:
1) Highly directional electret condenser, pluggable microphone with red ring luminant to
8/2/2019 IR System User Manual
6/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
6
identify the active unit.
2) Combined headset microphone which can be adjustable for comfortable wearing.
Built-in loudspeaker with volume level control. The selected incoming language channel is
heard when the microphone is switched off.
Automatic channel interlocking function prevents the interpreters from using the same outgoing
channel.
MUTE (cough cut) key for muting the microphone to prevent any unwanted sound/noise such
as cough.
SLOW key to alert the current speaker to speak slowly. When the key is pushed, a message
will be sent to the speaker and the red ring luminant will flash.
3.5mm REC output jacks on both sides to connect the recording device.
Multiple interpreter consoles can be connected in a daisy-chain to the IR transmitter or control
unit.
Technical Data:
Frequency response: 50Hz-18kHz
Distortion at 1 kHz: 85 dB
Signal-to-noise ratio: >90 Db
Max. input power level: 7.5V Input impedance: 2k ohms
Operating voltage: 24V
Standard microphone stem length: 425 mm
128x64 graphic backlit LCD screen
3m/5m/10m cable with DB25 connectors
6 x 3.5mm jacks for microphone, recorder, headphone
ABS base dimensions: 247X145X95mm (WDH)
8/2/2019 IR System User Manual
7/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
7
Descriptions for the function keys and indicators
1) A/B/C monitoring channel switch keys for a pre-select incoming language.
2) LED indicators for the pre-select A/B/C monitoring language channel.
3) Left/Right < > keys to select the incoming language channel for relay interpretation.
4) LED indicator for the relay interpretation channel.
5) LED indicator for the floor/original interpretation channel.
6) FLOOR key for the floor/original language channel. The indicator will light up when the key is
pushed to access the floor signal.
7) MUTE key: holding down the key to enable a brief muting of the microphone which will be
2
1
3
4
5
6
7
22
21
20
19
18
17
16
15
14
8
9
10
13
12
11
8/2/2019 IR System User Manual
8/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
8
active again when the key is released.
8) LED indicator for MUTE function
9) MIC on/off key: when the key is pushed to switch on the microphone, the mic indicator and the
red ring luminant on the pluggable microphone will light up. When the key is pushed to switchoff the microphone, all the delegate receivers will be automatically switched to original
language channel.
10) SLOW key to alert the current speaker to speak slowly. When the key is pushed, a message
will be sent to the speaker and the microphone red ring luminant will flash for some seconds.
11) Headphone output jack (3.5mm) on both sides
12) Microphone input jack (3.5mm) on both sides
13) REC output jack (3.5mm) to connect an audio recorder
14) Rotary switch for master/headphone volume level control
15) LED indicator for SLOW function
16) LED indicator for microphone on/off
17) Left/Right < > keys to select an outgoing channel
18) XLR connector for pluggable microphone
19) LCD screen
20) LED indicator for the left MIC jack. The indicator will light up when the left MIC input jack is
used.
21) MIC input key, which can be pushed to select the use of pluggable microphone or left/right
MIC input jacks.
22) LED indicator for the right MIC jack. The indicator will light up when the right MIC output
jack is used.
Setting an Outgoing Channel
Only one outgoing channel can be selected for interpreted language. Push the Left/Right
< > keys to select an outgoing channel. The selected channel number will flash on the
LCD for 3 seconds. Any occupied channel will be bypassed automatically when it is
selected.
Displays outgoing channel;displays the selected channel;displays the occupied channel.
8/2/2019 IR System User Manual
9/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
9
Direct Interpretation & Relay Interpretation
When the FLOOR key is pushed to monitor the floor language channel for direct interpretation, Left
/ Right < > keys are invalid.
For relay interpretation, A/B/C monitoring channel switch keys and Left / Right < > keys can be
used to select a language other than the floor language. The RELAY indicator will light up when the
relay interpretation is operated.
8/2/2019 IR System User Manual
10/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
10
Interpretation Time
displays the total time for the present interpretation
displays the total time for the previous interpretation
I nfrared Transmit t erModel No. TC-Z902V/904V/906B/908
The TC-Z902V/904V/906B/908 infrared transmitter is a microprocessor based central unit which is
designed to modulate and transmit 2, 4, 6 or 8 sound channels to different carrier frequencies. It
features built-in IR test diodes for audio monitoring and testing of receivers, built-in automatic level
control (ALC) to ensure comfortable listening levels, independent channel output level LED indicators,
and independent channel audio output sockets for sound recording. Test mode produces a different
frequency tone for each input/channel. Two BNC sockets can link up infrared radiators in two lines.
Modulation mode: FM
Frequency synthesis: digital PLL
Frequency band: 2.0 MHz - 6.0MHz
Frequency response: 100HZ-14KHZ
Frequency stability: 10ppm
Pre-emphasis: 75 Sec.
RF output impedance: 55-75 ohms
Input impedance: 18k ohms
Max. input power level: 7.5V
AGC range: 30dB
S/N ratio: >75dB
Power consumption: 40W
8/2/2019 IR System User Manual
11/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
11
Peak deviation: 7.5kHz
Distortion at 1 kHz: 70dB
RF output power level: 700mV
Power requirement: 110/220VAC, 50/60Hz
19" rack mountable case
Dimensions: 43099325 mm (WHD)
Weight: 7.6 kg
FRONT PANEL
1 POWER Power ON/OFF switch and indicator
2 LEVEL INDICATORS Output level LED indicators for each audio channel
REAR PANEL
3 AUDIO IN Unbalanced RCA audio input sockets (CH 0,1,2,3,4,5)
4 TEST ON/OFF switch for channel signal testing of receivers.
5 INTERPRETER UNIT Female DB25 port to connect male DB25 port on interpreters units rear panel.
6 AUDIO OUT Unbalanced RCA audio output sockets (CH 0,1,2,3,4,5)
7 SIGNAL OUT RF output BNC socket to connect the radiator
8 POWER INPUT AC power input socket (110/220V, 50/60Hz)
8/2/2019 IR System User Manual
12/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
12
I nfrared Radiator
Model No. TC-H15/25
The TC-H15/25 high-power infrared radiator is able to produce an average transmission output of
15watts/25watts and can be switchable to 50% low power, making it suitable for use in larger halls and
smaller rooms. The radiators integrated power supply unit is automatically switched on and off by the
carrier signals from the transmitter by means of a high frequency sensor. The radiator is equipped
with automatic gain control to ensure the infrared diodes function with maximum efficiency, and is
naturally convection cooled for totally silent and maintenance-free continuous operation. It can be
ceiling or wall mounted for permanent installation, or set up on an optional tripod for portable application.
Multiple radiators can easily be daisy-chained together to expand coverage. The unit is easy to
maintain and clean, with IR emitting diodes protected by the cover plate.
Frequency band: 2.0 MHz - 6.0 MHz
IR output power: 15W/25W
Switchable output level: Low/High (50%/100%)
Coverage range: up to 20 meters(15W) and 30 meters(25W)
RF output impedance: 55-75 ohms
RF input voltage: 100-2000mV
Power consumption: 55W / Stand-by 8W
Power Supply: 110/220VAC, 50/60Hz
Operating temperature: 0-40
Cable: 75-4 coax, BNC connectors
Dimensions: 450 211 82 mm (WHD)
Weight: 3.8 kg
8/2/2019 IR System User Manual
13/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
13
1 OUTPUT LEVEL SWITCH Slide switch for adjusting output level (HIGH 100% / LOW 50%)
2 TRIPOD HOLE For mounting radiator on a tripod for portable use
3 SIGNAL IN RF input BNC socket to connect the transmitter or the last radiator
4 SIGNAL OUT RF output BNC socket to connect the next radiator
5 POWER SWITCH Power on/off switch and indicator
6 POWER INPUT AC power input socket (110/220V, 50/60Hz )
8/2/2019 IR System User Manual
14/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
14
I nf rared Receiver w it h LCD
Model No. TC-J902/904/906LB/908L
The portable TC-J902/4/906LB/908L infrared receiver is designed to receive up to 2, 4, 6 or 8 audio
channels. The unit is powered by a more environment-friendly rechargeable Lithium-ion battery
pack. The selected channel number and battery level can be displayed on LCD screen. The user
may listen to any selected language on a personal earphone. Volume level can be adjusted
through a thumbwheel switch for comfortable listening. Any number of receivers can be used
within the radiators effective coverage range in an installation.
Modulation mode: FM
Frequency synthesis: digital PLL
Frequency range: 2 6 MHz
Frequency response: 100Hz-14kHz
De-emphasis: 75 Sec.
Peak deviation: 7.5kHz
Distortion at 1 kHz: 55dB
Channel separation: >55dBA Frequency stability: 10ppm
Power consumption: 50mW
Slide switch for power on/off
Thumbwheel switch for volume control
3.5mm phone output jack
Up/down push buttons for channel selection
LCD display for channel number & battery level
Pocket clip and lanyard for easy-wearing
Integrated charging electronics and contacts
Battery: 3.7V rechargeable Lithium-ion
LCD screen size: 33 x17mm
Dimensions: 1335723 mm (WHD)
Weight: 0.15 kg
8/2/2019 IR System User Manual
15/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
15
1 OPTICAL LENS Infrared light focusing device inside the plastic shield
2 LCD SCREEN LCD display for selected channel number & battery level
3 POCKET CLIP Integrated pocket clip for easy-wearing
4 CHARGING CONTACT Battery charging contact
5 PHONE JACK 3.5mm mini earphone jack
6 VOLUME CONTROL Thumbwheel switch for volume control
7 POWER ON/OFF Slide switch for power on/off
8 CHANNEL SELECTOR Up/down push buttons for channel selection
8/2/2019 IR System User Manual
16/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
16
I nf rared Receiver w it hout LCD
Model No. TC-J902/904/906B/908
The portable TC-J902/904/906B/908 infrared receiver is designed to receive up to 2, 4, 6 or 8 audio
channels. The optical lens offers a wider receiving angle to pick up the infrared light signal. The
delegate may listen to any selected language on a headphone/earphone. Volume level can be
adjusted through the volume control for comfortable listening. Any number of receivers can be used in
an installation.
Modulation mode: FM
Frequency synthesis: digital PLL
Carrier frequencies: 2.0 MHz - 6.0MHz
Frequency response: 100HZ-14HKZ
De-emphasis: 75 Sec.
Peak deviation: 7.5kHz
Distortion at 1 kHz: 55dB
Frequency stability: 10ppm
Operating voltage: 2.3V-3.6V
Power consumption: 50mW
Slide switch for channel selection
Thumbwheel switch for power on/off & volume control
3.5mm output phone jack
Battery type: 2 x AAA alkaline or rechargeable
Pocket clip and lanyard for easy-wearing
Dimensions: 1405830 mm (L x W x D)
Weight: 130g (excluding batteries)
8/2/2019 IR System User Manual
17/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
17
1 POWER ON INDICATOR LED indicator will light up when the receiver is turned on.
2 OPTICAL LENS Infrared light focusing device inside the plastic shield
3 PHONE JACK 3.5mm mini earphone jack.
4 POCKET CLIP Integrated pocket clip for easy-wearing
5 POWER / VOLUME Thumbwheel switch for power on/off and volume control
6 CHANNEL SELECTOR Slide switch for channel selection (Ch 0,1,2,3,4,5)
8/2/2019 IR System User Manual
18/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
18
TC-D2 Interpreter Headset
Closed-ear stereo headset with mic and vol control
Connectors: 3.5mm stereo plugs
Impedance: 6015%
Frequency response: 20Hz to 20KHz
Input power: 30-50mW
Sensitivity (1 kHz): -582dB
Microphone type: Omni-directional dynamic
Microphone sensitivity (1 kHz): -582dB
Cord length: 2 meters
TC-D1 Delegate Earphone
Type: dynamic 40mm
360 swivel clip-on hanger
Frequency response: 7Hz to 24KHz
Sensitivity: 102dB3dB
Impedance: 4010%
Input power: 8-50mW
120 cm cord with 3.5mm plug
Full range enhance system
Super bass frequency technology
RY-123 Receiver Lanyard
Designed for receiver unit s easy wearing
Length: 40 cm
GX-48 Receiver Carrycase
Handy locking aluminum/plastic suitcase
Designed for carrying/storage of receivers
48 positions with pre-cut foam
Dimensions: 503320cm
8/2/2019 IR System User Manual
19/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
19
UA-203 Radiator Bracket
Swivel bracket for wall/ceiling mounting
Adjustable angle
GX-315 Radiator Tripod
Type: floor standing, foldable 3-way pan tripod
Height: 60cm to 150cm
DB25 Interpreter Cable
25-p male/female parallel cable
Length: 3m/5m/10m
75-4-128 Radiator Coaxial Cable
Connectors: BNC type, 2 x male
Length: 10 meters
8/2/2019 IR System User Manual
20/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
20
Radiator Mount ing
1. Wall mounting routing cables upward 2. Wall mounting routing cables downward
3. Ceiling mounting 4. Floor-standing tripod mounting
8/2/2019 IR System User Manual
21/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
21
System Conf igur at ion Diagram
8/2/2019 IR System User Manual
22/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
22
System Connect ion
CONNECTION SOCKETS CABLE
1
Conference System Central Unit
TransmitterAudio output
AUDIO IN (CH 0) Audio cable2
External Sound System
TransmitterAudio output
AUDIO IN (CH 1-5) socket Audio cable
3Transmitter
Interpreter ConsoleINTERPRETER UNIT portINPUT port
DB25 shielded cable
4Transmitter
RadiatorSIGNAL OUT
(SIGNAL) IN 75-4 coaxial cable
System Test ing
After all the system components are connected, make sure the TEST switch is OFF on the transmitters
rear panel. Turn on power for the transmitter and radiators, and then turn on the TEST switch. The
level indicators on the transmitters front panel will light up. Listen to the test signal for every channel
via an infrared receiver. Walk about the conference venue. If there is any blind area, adjust the
radiators mounting angle or HIGH/LOW output level. After the testing is finished, turn the TEST
switch to OFF position.
Turn on the interpreter microphone, conference system central unit and other audio equipment, and
then choose an output channel to see if the signal can be heard via the receiver.
Please note: 1) The receivers should be used at least 5 meters away from any radiator. 2) The floor
signal should be connected to the CH0 input socket on the transmitter rear panel. 3) The transmitter
and the radiators should use an external power supply with a ground.
8/2/2019 IR System User Manual
23/23
TC-902/904/906/908 IR SYSTEM USER MANUAL
23
Limi ted Warrant y
GONSIN warrants that the hardware products it manufactures will be free from defects in
materials and workmanship. The warranty term, beginning on the date of invoice, is one year for
parts replacement, two years for parts repair and six months on accessories.
This warranty does not cover damage or failure caused by alterations, mishandling, abuse,
misuse, neglect, accident or resulting from any cause other than a product defect.
In case of defects in material and workmanship under normal use and conditions, GONSIN will
replace or repair products covered under this limited warranty that are returned to GONSINs
facility.
To request warranty service, you must contact GONSIN international sales team within the
warranty period, ship the products back to GONSIN in their original or equivalent packaging
(freight prepaid). If GONSIN repairs or replaces a product, its warranty term is not extended.
Guangdong Gonsin Digital Equipment Corporation
Factory: 40 Shunxiang Road, Fengxiang Industrial Park, Shunde, Foshan, Guangdong 528300, China.Tel: 86-757-22360969 Fax: 86-757-2238-2370 Email: [email protected]