Iplex Mx r Manual

Embed Size (px)

Citation preview

  • 8/16/2019 Iplex Mx r Manual

    1/92

    INSTRUCTIONS

    INDUSTRIAL VIDEOSCOPE

    IPLEX MX R series

  • 8/16/2019 Iplex Mx r Manual

    2/92

  • 8/16/2019 Iplex Mx r Manual

    3/92

    Contents

    IPLEX MX R series i

    Contents

    Labels and Symbols ................................................ 1Important Information – Please Read Before Use.... 3

    Intended use.........................................................................3Instruction manual ................................................................3Instrument compatibility........................................................3Repair and modification........................................................3Signal words.........................................................................4Dangers, warnings and cautions ..........................................4Handling of the battery .........................................................6Product configurations of the IPLEX MX R series................9

    Chapter 1 Checking the Package Contents........ 10 1.1 Checking the package contents ............................... 10

    IPLEX MX R series package contents..................11

    Chapter 2 Nomenclature and Functions............ 12 2.1 MX R main unit ..........................................................12

    2.2 Control unit ................................................................162.3 LCD monitor ..............................................................172.4 Monitor display ..........................................................182.5 Side view mirror adapter ...........................................19

    Storing the side view mirror adapter .....................192.6 Side view rigid sleeve (optional) ...............................202.7 External battery case (optional) ................................21

    Chapter 3 Preparation and Inspection ................ 22

    3.1 Transportation of the case.........................................22There are 4 ways to carry the case as follows: ..... 22Taking the instrument out of the case ...................24

    3.2 Installation of equipment ...........................................25Setup .................................................................... 25

    3.3 Preparation of power supply......................................26Supplying power from the internal battery ............26Supplying power from the external battery ...........27

    Supplying power from the AC adapter ..................273.4 Inspection of the scope .............................................28

  • 8/16/2019 Iplex Mx r Manual

    4/92

    Contents

    ii IPLEX MX R series

    Checking the scope distal end.............................. 283.5 Inspection of the side view mirror adapter (optional)

    (with the IV7620X2/IV7630X2) ..................................29Checking the side view mirror adapter and

    connection screws........................................... 29Attaching or detaching the side view mirror

    adapter ............................................................30Checking loose parts of the side view mirror

    adapter ............................................................32Checking the scope appearance ..........................32

    3.6 Inspection of the LCD monitor................................... 32Checking the LCD cable .......................................32Checking the appearance ..................................... 33

    3.7 Inspection of the control unit ..................................... 34Checking the appearance and universal cable ..... 34

    3.8 Inspection of the basic functions ............................... 34Checking the power supply...................................34Checking the LCD monitor image......................... 35Checking the illumination lighting..........................35Adjusting the white balance .................................. 36

    Checking the angulation ....................................... 36Checking the angulation lock mode ......................36

    3.9 Attaching and detaching of the belts ......................... 37Attaching the belts ................................................37Detaching the belts ...............................................39

    3.10 Installation of the control unit on the main unit ..........393.11 Installation of the scope and universal cable

    on the main unit.........................................................40Attaching the scope fixing belt ..............................40Fixing the scope....................................................41Fixing the universal cable .....................................41

    Chapter 4 Operation of the Basic Functions ...... 42 4.1 Turning power ON .....................................................42

    Image display........................................................42Illumination ON-OFF.............................................42

    4.2 Insertion of scope and observation ...........................43Holding the control unit and scope ....................... 43Inserting the scope ...............................................43

  • 8/16/2019 Iplex Mx r Manual

    5/92

    Contents

    IPLEX MX R series iii

    Angulating the scop ..............................................44Adjusting the LCD monitor screen brightness ...... 45

    4.3 Adjustments of image freeze, zoom and brightness ......45Freezing the image ...............................................45Zooming the image ...............................................46Adjusting the image brightness.............................47Monochrome boost ...............................................48

    4.4 Image recording/playback on/from recording card(CF card loaded in the CF card adapter)...................49

    Recording the image.............................................49Playing back the image......................................... 51How to use IPLEX MANAGER..............................52

    4.5 Menu operation .........................................................54Live image display menu and its functions............54View image (played image) display menu

    and its functions ..............................................594.6 Remaining battery power ..........................................614.7 Battery replacement ..................................................624.8 Withdrawal of the scope ............................................63

    Releasing the angulation lock ...............................63

    Withdrawing the scope.......................................... 634.9 Turning power OFF....................................................644.10 Cleaning of the scope................................................644.11 Storage in the case ...................................................65

    Chapter 5 Storage Precautions ........................... 67

    Chapter 6 Troubleshooting .................................. 68 6.1 Troubleshooting guide ...............................................69

    Error messages ....................................................69Irregularities under normal use.............................70

    6.2 Returning the instrument for repair............................72

    Chapter 7 Specifications ...................................... 73 Operating environment .........................................73Specifications (The specifications of the side view

    mirror adapter is provided separately.) ............74Specifications of the side view mirror adapter ...... 81

    Appendix................................................................. 83 System chart ......................................................................83

  • 8/16/2019 Iplex Mx r Manual

    6/92

    Labels and Symbols

    1 IPLEX MX R series

    Labels and Symbols

    Safety-related labels and symbols are attached to the instrument at thelocations shown below.

    If labels or symbols are missing or illegible, please contact Olympus.

    1. Rating plate A

    2. Rating plate B

    3. Rating plate onLCD monitor

  • 8/16/2019 Iplex Mx r Manual

    7/92

    Labels and Symbols

    IPLEX MX R series 2

    1. Rating plate A

    2. Rating plate B

    3. Rating plate on LCD monitor

    T V T Y P E N T S C

    Item# * * * * * * *

    Ser ia l# * * * * * * *

    WARNING

    CAUTION

    Never attempt to use this instrument in an areaexposed to flammable gas.

    Hazardous voltage may result in electric shock.Do not remove safety cover.

    7.8W

  • 8/16/2019 Iplex Mx r Manual

    8/92

    Important Information – Please Read Before Use

    3 IPLEX MX R series

    Important Information – Please ReadBefore Use

    Intended useThis instrument has been designed to be used with IPLEX MX R series andancillary equipment for observation and examination of the insides of amachinery, equipment or building that cannot be observed directly from theoutside.

    Do nor use this instrument for any purpose other than its intended use, par-

    ticularly for observation or examination of the inside of a human or animalbody cavity.

    Instruction manual This instruction manual contains essential information on using this instru-ment safely and effectively.

    Before use, thoroughly review this manual and the manuals of all equip-ment which will be used during the procedure and use the equipment asinstructed.Keep this and all related instruction manuals in a safe, accessible location.If you have any questions or comments about any information in this man-ual, please contact Olympus.

    Instrument compatibility Refer to the “System chart” in the Appendix to confirm that this instrumentis compatible with the ancillary equipment being used.Using incompatible equipment can result in malfunction and/or equipmentdamage.

    Repair and modification

    This instrument does not contain any user-serviceable parts. Do not disas-semble, modify or attempt to repair it, or human injury and/or equipmentdamage can result.

  • 8/16/2019 Iplex Mx r Manual

    9/92

    Important Information – Please Read Before Use

    IPLEX MX R series 4

    Signal wordsThe following signal words are used throughout this manual.

    Indicates an imminently hazardous situation which, if notavoided, will result in death or serious injury.

    Indicates a potentially hazardous situation which, if notavoided, could result in death or serious injury.

    Indicates a potentially hazardous situation which, if notavoided, may result in minor or moderate injury. It may alsobe used to alert against unsafe practices or potential equip-ment damage.

    Indicates additional helpful information.

    Dangers, warnings and cautionsFollow the dangers, warnings and cautions described below when han-dling this instrument. The information is to be supplemented by the dan-gers, warnings and cautions given in each chapter.

    Never use this instrument in observation inside the humanand animal cavity. The human body or animal may be injured.

    • Never use this instrument in a flammable atmosphere. Other-wise, an explosion or fire may result.

    • This instrument is not designed waterproof. Never use it in asituation in which it may be immersed in water. Otherwise, anelectric shock may result.

    • Never use this instrument on a piece of electrical equipmentbeing energized. Since the exterior finish of the scope is elec-troconductive, an electric shock may occur if it is brought incontact with an active part.

  • 8/16/2019 Iplex Mx r Manual

    10/92

    Important Information – Please Read Before Use

    5 IPLEX MX R series

    • Always set the LIGHT switch to OFF when discontinuing useof this instrument otherwise the light emitted from the scopemay heat a nearby object and cause fire ignition.

    • Do not use this instrument in an environment containing fine

    particles such as metal dust.• The distal end of the scope becomes hot due to the internal

    heat build-up due to the illumination light and electrical parts.Turn the light source OFF before attaching or detaching theside view mirror adapter on or from the scope. To preventburning your hand, take special care not to touch the scope’sdistal end after use in an high-temperature atmosphere.

    • Do not allow the light emitted from the scope’s distal end enteryour eye directly. Otherwise, an eye injury may result.

    • Should any abnormality be detected during angulation opera-tion, do not continue the angulation operation by force. Other-wise, the scope or examination target may be damaged.

    • Do not subject the LCD surface to impact or strong pressure.Doing so could shatter the LCD screen and cause personalinjury.

    • Do not allow a metallic object or a fluid such as water enter thebattery compartment, DC IN connector or RECORDINGCARD slot. Should any foreign object enter the instrument,never turn it ON but immediately contact Olympus.

    • Do not touch the connectors directly by hand. Otherwise, amalfunction or electric shock may result.• Do not allow a metallic or any foreign object enter the instru-

    ment through the air inlet or outlet. Otherwise, a malfunction orelectric shock may result.

    • In case an irregularity such as smoke, abnormal odor orabnormal noise is detected, immediately stop using the equip-ment even when it looks operable, and do not turn it ON again.

    • Do not insert the scope in a machine that is running, as thismay result in the scope and/or machine damage. Also do notrun the machine while the scope is inserted in it.

    • Do not bend the scope by a radius of less than 20 mm withthe IV7415X2 or IV7430X2 or less than 30 mm with theIV7620X2 or IV7630X2. Otherwise, the scope may be dam-aged.

    • Do not bring the scope in contact with a liquid other thanwater, saline, machine oil and light oil. Otherwise, the equip-

    ment may be damaged.• Protect the equipment other than the scope from liquids such

    as rainwater. Otherwise, equipment damage may result.

  • 8/16/2019 Iplex Mx r Manual

    11/92

    Important Information – Please Read Before Use

    IPLEX MX R series 6

    • Do not cover the instrument with a plastic bag or other objectduring use. If the inside of the instrument cannot be cooled,the instrument damage may result.

    • Do not insert or remove a recording card into or from theRECORDING CARD slot while the “ACCESS” operation indi-cator is lit. Otherwise, the data recorded in the recording cardmay be destroyed.

    • Do not use this instrument in a high-temperature, high-humidity environment. When the instrument is brought in alow-temperature environment such as outdoors in winter,leave the instrument in the operating environment for a whilebefore use. Otherwise, condensation inside the instrumentmay cause malfunction.

    • Take care not to have your feet caught by a cord includingthe power cord or scope insertion tube.• Do not pull the cable of the scope, control unit or other equip-

    ment with a strong force. Otherwise, the scope or cable maybe damaged or the instrument may topple down or drop.

    • The images recorded with instrument can be displayed on aPC, etc., but it is not possible to play back images recorded withan image recording device such as a digital camera or a PC onthe IPLEX MX R series instrument. Also note that the imagesrecorded with an IPLEX MX R series instrument cannot beplayed back if the images are recorded in a different TV format(PAL).

    Handling of the battery Follow the dangers, warnings and cautions described below when han-dling the battery. Otherwise, battery fluid leak, excessive heat generation,smoke, battery burst, electric shock and/or burns may result.

    • In case of Li-ion operation, be sure to use the battery and bat-tery charger designated for IPLEX MX R series.

    • Before use, thoroughly review the instruction manuals for thebattery and battery charger to fully understand the informationcontained in them, and observe their instructions during use.

    • Do not install and use the battery by reversing the polarity. Ifthe battery cannot be installed properly in the instrument, donot attempt to insert it by force.

  • 8/16/2019 Iplex Mx r Manual

    12/92

    Important Information – Please Read Before Use

    7 IPLEX MX R series

    • Do not attempt to apply solder directly on a terminal. Other-wise, a hazardous situation such as destruction of the terminalsafety valve or scattering of alkaline fluid may result.

    • Do not interconnect the electrodes of the battery through a

    metallic object or carry nor store the battery together with ametallic necklace or hairpin.

    • Do not connect the battery directly to a power outlet or thecigar lighter of an automobile.

    • Do not throw the battery in fire or heat the battery.• Penetration of battery fluid in an eye may result in loss of eye-

    sight. Should this occur, rinse eyes thoroughly with cleanwater and immediately have a physician’s treatment.

    • Do not attempt to open or modify the battery.• Do not immerse the battery in fresh or sea water, nor moisten

    the battery.• Do not recharge the battery near a fire or under direct sunlight.• Do not pierce the battery with a needle, hit the battery with a

    hammer or step on the battery.• Do not apply a strong shock to the battery or throw it.

    • Do not use a battery that is not recommended for IPLEX MX R

    series.• Do not attempt to recharge a battery that is not designated forIPLEX MX R series.

    • If the battery charger cannot complete battery charging in thespecified recharging time, stop trying to recharge the battery.

    • Do not use a battery if it presents an irregularity such as fluidleak, discoloration, deformation or abnormal odour.

    • If the battery fluid attaches to your skin or clothes, immediatelyrinse with clean water such as tap water. Otherwise, a skininjury may result.

    • Do not deform the battery compartment or put a foreign objectin it.

    • Do not cover the battery charger and battery with clothes orcushion during recharging. Also avoid any situation in whichthe covering of the battery charger and battery by such objectsis expectable.

    • Do not soak the battery in or moisten it with water includingrainwater and seawater.

    • Do not leave the battery in a place subject to moisture, waterleak or extremely high or low temperatures.

  • 8/16/2019 Iplex Mx r Manual

    13/92

    Important Information – Please Read Before Use

    IPLEX MX R series 8

    • Do not touch the charging terminals or power plug with a wethand.

    • Be sure to recharge the battery before using them for the firsttime after purchase or after they have not been used for a longperiod.

    • When the battery is not to be used for a long period, be sure toremove them from IPLEX MX R series. Otherwise, batteryfluid leak and heat build-up may result in a fire or injury.

    • When an irregularity such as battery fluid leak, discoloration ordeformation is detected, stop using the battery and contactOlympus.

    • Do not use or leave the battery in a place with high tempera-ture, for example under direct sunlight, in a closed automobile

    under the sun or in front of heating equipment.• The battery is hot after long hours of operation of IPLEX MX Rseries. Do not take out the battery immediately after use, asthis may result in burning your hand.

    • Do not leave the battery in the reach of children.

    • Use the battery correctly, as incorrect use may result in fluidleak, excessive heat generation and/or damage. When replac-ing the battery, install them correctly by observing the insertiondirection.

    • In general, the battery performance drops as the ambient tem-perature drops.Note that the battery performance degraded due to low tem-peratures recovers when the temperature rises to a normallevel.

    • Contamination of battery electrodes with sweat or oil willcause contact failures. When the battery is dirty, wipe it cleanwith a dry cloth before use.

    • The continuous operating time of the IPLEX MX R series timewith a fully charged battery condition is approx. 120 min.(operated with a brand-new model at normal temperature[27°C/81°F]). When long hours of battery-powered operationare expected, it is recommended to prepare charged batteriesas spares.

    • The E/F slide switch on the side of the battery is a manualswitch used to assist you checking if the battery is empty orfully charged. Set the switch to “ F ” after fully charging the bat-tery and to “ E ” after it has been discharged. (This switch isconnected electrically to nothing. It is exclusively used as areminder that you have recharged or emptied the battery.)

  • 8/16/2019 Iplex Mx r Manual

    14/92

    Important Information – Please Read Before Use

    9 IPLEX MX R series

    • The battery is designated as a recyclable product. When dis-continuing the use of the battery, be sure to have it recycled incompliance with your local regulations.

    • Recommended temperature range for Li-ion battery operationDischarge (when using the instrument): 0°C to 40°CRecharging: 0°C to 40°CStorage: -20°C to +50°CUsing the battery under a temperature outside the above tem-perature range will result in degradation of the performanceand service life. When storing the battery, be sure to remove itfrom IPLEX MX R series.

    • The battery is a consumable item.

    Product configurations of the IPLEX MX R series

    The following table shows the product configuration of the IPLEXMX R series according to the maximum outer diameter andlength of the insertion tube.

    For detailed specifications of the individual models models, seeChapter 7, “Specifications” .

    IPLEX MX R series

    model names

    Max. insertion tube

    outer diameter

    Insertion tube

    lengthIV7415X2 φ 4.4 mm 1.5 m

    IV7430X2 φ 4.4 mm 3 m

    IV7620X2 φ 6 mm 2 m

    IV7630X2 φ 6 mm 3 m

  • 8/16/2019 Iplex Mx r Manual

    15/92

    Checking the Package Contents

    IPLEX MX R series 10

    Chapter 1 Checking the PackageContents

    1.1 Checking the package contents

    Match all items in the package with the components shown in “IPLEX MXR series package contents” on page 11. If the instrument is damaged, acomponent is missing or your have any questions, do not use the equip-ment, but immediately contact Olympus.

  • 8/16/2019 Iplex Mx r Manual

    16/92

    Checking the Package Contents

    11 IPLEX MX R series

    IPLEX MX R series package contents

    IPLEX MX R main unit..........................................................1

    AC adapter ...........................................................................1

    AC power cable ....................................................................1

    AC adapter instruction manual .............................................1

    Belt set (Shoulder belt, waist belt and scope lock belt) ........1

    Soft handle ...........................................................................1

    CF adapter............................................................................1

    Recording card .....................................................................1

    Cleaning kit...........................................................................1

    IPLEX Manager (Image management software) ..................1

    Instruction Manual (This booklet) .........................................1

  • 8/16/2019 Iplex Mx r Manual

    17/92

    Nomenclature and Functions

    IPLEX MX R series 12

    Chapter 2 Nomenclature andFunctions

    2.1 MX R main unit

    LCD monitor

    Scope

    Angulating section

    Front panel

    Universal cable

    Bend stopper

    Insertion tube

    MX R main unit

    Control unit

    Soft handle

  • 8/16/2019 Iplex Mx r Manual

    18/92

    Nomenclature and Functions

    13 IPLEX MX R series

    Lock section

    Hanger holder

    West beltShoulder belt

    Scope lockbelt

  • 8/16/2019 Iplex Mx r Manual

    19/92

    Nomenclature and Functions

    IPLEX MX R series 14

    Upper belt holder

    Dust cover

    RECORDING CARD slot(Insert a recording cardfor image recording.)

    Video output terminal

    (Connect the externalmonitor using the BNCcable (MB-885).

    S-Video output terminal

    AC adapter connector

    Foot

    POWER switch

    Battery compartment door

    Lower belt holder

  • 8/16/2019 Iplex Mx r Manual

    20/92

    Nomenclature and Functions

    15 IPLEX MX R series

    • This product is not designed drip-proof except the insertionsection. Be careful not to expose it to rain, etc.

    • Be sure to connect the optional MH-888 S-video cable withcore to the S-video output terminal.Connect the plug with core of the S-video cable to the S-videooutput terminal of IPLEX MX R.

    ① POWER indicator lamp ⑥ LIVE button② MENU button ⑦ VIEW button③ button ⑧ LIGHT button④ button ⑨ LIGHT indicator ⑤ ENTER button

    Side view mirror adapter storage section

    ① ② ③ ⑤ ⑥ ⑨

    ④ ⑦ ⑧

  • 8/16/2019 Iplex Mx r Manual

    21/92

    Nomenclature and Functions

    IPLEX MX R series 16

    2.2 Control unit

    Hanger

    [ANGLE LOCK] button

    [FRZ/REC] button

    Grip

    [BRT] lever

    Joystick

    Image magnification[ZOOM] lever

    Augulation operation

    [BOOST] buttonMonochrome boostingfunction

    Brightness

    Joystick guard

    adjustment

    To freeze observed imagesand record images. (locatedon the left and right sides)

    To fix the control sectionon the main unit

    To lock the bending angle

  • 8/16/2019 Iplex Mx r Manual

    22/92

    Nomenclature and Functions

    17 IPLEX MX R series

    2.3 LCD monitor

    LCD cable

    POWER switch

    LCD monitor lock

    LCD connector Brightness buttons

    Shade

  • 8/16/2019 Iplex Mx r Manual

    23/92

    Nomenclature and Functions

    IPLEX MX R series 18

    2.4 Monitor display

    This instrument employs the OSD (On-Screen Display) method. The setup

    menus and status of the instrument are displayed on the LCD monitorscreen as required.

  • 8/16/2019 Iplex Mx r Manual

    24/92

    Nomenclature and Functions

    19 IPLEX MX R series

    2.5 Side view mirror adapter

    Attaching the optional AT50S-IV76X2 side view mirror adapter

    with the IV7620X2 or IV7630X2 makes it possible to change theorientation of its field of view sideways.

    Storing the side view mirror adapter

    When the side view mirror adapter is not used, it can be stored inthe storage section in the LCD monitor lock section.

    Objective lensMirror

    Name symbol

    Side view mirror adapter lock groove

    Nut

    Lock screw

    Storage section cover

    Side view mirror adapter

    Side view mirror adapter

    Illumination

  • 8/16/2019 Iplex Mx r Manual

    25/92

    Nomenclature and Functions

    IPLEX MX R series 20

    2.6 Side view rigid sleeve (optional)

    Attaching the optional MAJ-1730 (with the IV7415X2, IV7430X2) orMAJ-1731 (with the IV7620X2 or IV7630X2) side view rigid sleevemakes it possible to use the IPLEX MX series as a rigid videoscope andchange the orientation of its field of view sideways. For the operation ofthe side-view rigid sleeve, refer to the instruction manual for the MAJ-1730 or MAJ-1731.

    Side view rigid sleeve

  • 8/16/2019 Iplex Mx r Manual

    26/92

    Nomenclature and Functions

    21 IPLEX MX R series

    2.7 External battery case (optional)

    The optionally available MAJ-1375 external battery case is designed toextend the operating time of the instrument by adding an externallymounted battery. Adding the external battery to the battery of the IPLEXMX R increases its battery operation time, and using only the external bat-tery for operation of the IPLEX MX R enables the quiet mode in which thefan noise of the MX R main unit can be reduced.For the operation and installation of the external battery case, refer to theinstruction manual for the MAJ-1375 external battery case.

    External battery case

    Connection cable

  • 8/16/2019 Iplex Mx r Manual

    27/92

    Preparation and Inspection

    IPLEX MX R series 22

    Chapter 3 Preparation andInspection

    • Before each use, prepare and inspect this instrument asinstructed below. Should the slightest irregularity be sus-pected, do not use the instrument and see Chapter 6, “Trou-bleshooting.” If the irregularity is still suspected afterconsulting

    Chapter 7, contact Olympus.Damage or irregularity may compromise the correct function-ing of the instrument and may result in more severe damage tothe examined subject.

    • Inspections are not required only before use, but should beconducted periodically and scrupulously.

    3.1 Transportation of the case

    Before transporting the case, inspect the exterior parts, han-dles, extensible handle, wheels and latch of the case forirregularities such as damage and loosening.

    Figure 3.1

    There are 4 ways to carry the case as follows:

    1. Using the handle.

    2. Using the belt with the case put horizontally.3. Using the belt with the case put vertically.4. Using the wheels.

    Latch

    Wheel

    Belt

    Handle

  • 8/16/2019 Iplex Mx r Manual

    28/92

    Preparation and Inspection

    23 IPLEX MX R series

    • Ensure that the latches are closed firmly before lifting thecase. Otherwise, the top cover may open accidentally openwhen the case is lifted.

    • Do not attempt to move the case by kicking it, etc. Doing somay damage the case.

    • When using the belt, clamp the two extremities of the beltfirmly to the case. Otherwise, the belt may be detached acci-dentally when the case is lifted (see Figure 3.2).

    • When using the wheels, the belt should be attached to theopposite side to the wheels. Be sure to adjust the belt lengthproperly (see Figure 3.3).

    • Always bring the wheels in contact with the floor before trans-porting the case. Otherwise, the case may be damaged or top-ple down.

    • Move the case slowly when overcoming a step to prevent thecase from toppling down.

    How to attach the belt

    Figure 3.2

    How to transport the case by the wheels

    Figure 3.3

    Open the claws and insert the metallic part of the belt.

  • 8/16/2019 Iplex Mx r Manual

    29/92

    Preparation and Inspection

    IPLEX MX R series 24

    Taking the instrument out of the case

    Take out IPLEX MX R modules in order of the scopecontrol unit main unit.

    Figure 3.4

    • Never use the MX R main unit while it is accommodated insidethe case. If the top cover of the case is left open, unexpectedclosing of the top cover may cause a hand or cable to becaught by it.

    • To open the top cover of the case, release the latch on theside of the case.

    • Do not pull the scope with an excessive force when taking itout of the pocket.

    • When taking out the control unit and main unit, never holdthem by the scope (including the bend stopper), universalcable, LCD cable or LCD monitor. Otherwise, the equipmentmay be damaged. To facilitate taking out the main unit, it isrecommended to attach the soft handle to it.

    • The soft handle is designed to remove the main unit from thecase and is not a transportation belt. Do not attempt to use itfor transportation.

    Pocket Control unit Soft handle

    Main unit

    Mainunit

    Inner cover

    Innercover

    Scope

    Take out.

    Unseal the Velcro and takethe scope out of the pocket.

    Open the pocket flap and takeout the control unit and then themain unit.

    Attach the soft handle to themain unit, and pull it out.

  • 8/16/2019 Iplex Mx r Manual

    30/92

    Preparation and Inspection

    25 IPLEX MX R series

    3.2 Installation of equipment

    Setup

    1. Place the IPLEX MX R main unit on a flat surface so that it does notrattle. The main unit can be operated either on its side or on its bot-tom (see Figure 3.5).

    • Do not install the main unit on a high position. Otherwise, themain unit may fall from it.

    • Do not block the air vents when installing the main unit. Other-wise, insufficient cooling of the inside of the main unit mayresult in damaging it.

    Figure 3.5

    MX R main unit operated

    on its side

    MX R main unit operated

    on its bottom

  • 8/16/2019 Iplex Mx r Manual

    31/92

    Preparation and Inspection

    IPLEX MX R series 26

    3.3 Preparation of power supply

    • Do not bend, pull, twist, crush or apply excessive force to thepower cord of the AC adapter. Otherwise, disconnection of thepower cord wires may cause a fire or electric shock.

    • Ensure that the power cord is normal before connecting it.Using a power cord with irregularities may result in an electricshock.

    • When replacing the battery, be careful not to have your handinjured with the battery compartment door.

    • When replacing the battery, be careful not to drop it by mis-take.

    • Before using the battery, read the dangers, warning and cau-tions in “Handling of the battery” under “Important Information

    – Please Read Before Use.”• A caution is displayed when a battery is continued to be used

    under the low-voltage condition. If the use of the battery is notdiscontinued, the instrument will eventually be shut down.

    Supplying power from the internal battery

    Figure 3.6 Figure 3.7 Figure 3.8

    1. Ensure that the power switch of the MX R main unit is set to “ O ” (OFF).2. Open the battery compartment door by raising the latch on it.3. Insert a fully charged battery by pushing the battery compartment

  • 8/16/2019 Iplex Mx r Manual

    32/92

    Preparation and Inspection

    27 IPLEX MX R series

    door with the battery and aligning the notches. Be sure to insert thebattery in the correct polarity.

    Figure 3.9 Figure 3.10

    4.Push in the battery until it clicks.

    5. Close the battery compartment door and tilt the latch to lock the door.

    Supplying power from the external battery

    The optional external battery case makes it possible to addanother battery and extend the operating time of the instrument.When only the external battery is used for operation of the IPLEXMX R, it can be used in quiet mode in which the fan noise of theMX R main unit can be reduced.

    For operation and installation of the external battery case, followthe instructions in the manual provided with the optional MAJ-1375 battery case.

    Supplying power from the AC adapter

    1. Connect the AC adapter to the DC IN connector of the IPLEX MX Rmain unit.

    2. Ensure that the AC power cord is connected securely to the AC inletof the AC power adapter.

    3. Plug the AC power cord securely into a power outlet.

    • Never connect the grounding pin to a gas pipe this may causean explosion.

  • 8/16/2019 Iplex Mx r Manual

    33/92

    Preparation and Inspection

    IPLEX MX R series 28

    • Ensure that the power cord is normal before connection. Usinga power cord with irregularities may result in an electric shock.

    • Never use an AC adapter other than the exclusive ACadapter. Otherwise, malfunction of the instrument and/orunexpected accident may result.

    3.4 Inspection of the scope

    • Be always sure to hold the scope by a position located on therear of the angulation section. Otherwise, the angulation sec-tion may be damaged.

    Checking the scope distal end

    • Never use the scope if any part of it is loose. Otherwise, the

    loose part may drop during use.• The distal end of the scope becomes hot due to the illumi-

    nation light or internal heat build-up by electrical parts.Particularly, take special care after using the scope in ahigh-temperature atmosphere to prevent burns.

    1. If the side view mirror adapter is attached to the scope, turn the nutcounterclockwise to detach the side view mirror adapter from thescope.

    2. Check that the Objective lens and LED at the distal end of the scopeare clean. If they are dirty, wipe them clean using a piece of clean,soft gauze or a cotton swab. They can be cleaned better if the pro-vided lens cleaning kit is used.

    3. Check that the parts on the scope distal end are not deformed orloose.

  • 8/16/2019 Iplex Mx r Manual

    34/92

    Preparation and Inspection

    29 IPLEX MX R series

    3.5 Inspection of the side view mirror adapter(optional) (with the IV7620X2/IV7630X2)

    • The distal end of the scope becomes hot due to the illumina-tion light or internal heat build-up by electrical parts. Be sure toset the LIGHT switch to OFF before attaching or detaching theside view mirror adapter. Particularly, take special care afterusing the scope in a high-temperature atmosphere to preventburns.

    Checking the side view mirror adapter and connectionscrews

    1. Check that the mirror of the side view mirror adapter is clean. If it isdirty, wipe it clean using a piece of clean, soft gauze or a cottonswab. It can be cleaned better if the provided lens cleaning kit is used(see Figure 3.11).

    • Do not wipe off metallic particles, sand or soil attached to themirror surface of the side-viewing mirror adapter. Doing somay scratch the mirror surface. Remove the side viewing mir-ror adapter from the scope, and use running water to wash outmetallic particles, sand or soil attached to the mirror surface.

    Figure 3.11

    2. Check the bores connection diameters of the side of the scope distalend, side view mirror adapter lock groove and side view mirroradapter, and that their screws (see Figure 3.12) are not deformed orhave foreign objects attached to them.

  • 8/16/2019 Iplex Mx r Manual

    35/92

    Preparation and Inspection

    IPLEX MX R series 30

    Attaching or detaching the side view mirror adapter

    • If the side view mirror adapter cannot be attached or detachedbecause its nut will not turn, stop using the equipment andcontact Olympus.

    • The side view mirror adapter is a precision instrument usingglass mirrors in the optics. Be careful not to drop it or apply astrong impact to it.

    • The mirror surface of the side viewing mirror adapter is anoptical component. It is susceptible to stains and scratches.

    • Do not attempt to insert the scope into the side view mirroradapter by force. Otherwise, it would become impossible towithdraw the scope later.

    • If the side view mirror adapter cannot be clamped completelyby tightening the nut, the threads may be contaminated. Applythe provided cleaning fluid on the inner side of the nut of theside view mirror adapter and turn the nut. This will clean thethreads and makes it possible to clamp the side view mirroradapter completely.

    • If the threads are extremely dirty or the claw inside the sideview mirror adapter is contaminated, remove the nut from theside view mirror adapter and clean it.

    1. When inserting the side view mirror adapter into the scope’s distalend, set the nut so that the green index is visible entirely (see Figure3.12).

    • Gently insert the side view mirror adapter into the scope’s dis-tal end and push in the adapter until the claw inside it isengaged with the clamping groove on the scope's distal end.

    • If insertion is impossible, turn the side view mirror adapter sothat its mirror rotates and confirm secure fitting. The side view

    mirror adapter should be turned clockwise until the firstthreaded section of the nut goes beyond the connection screwsection (see Figure 3.12).

    Figure 3.12

    Green indexNut Mirror section

  • 8/16/2019 Iplex Mx r Manual

    36/92

    Preparation and Inspection

    31 IPLEX MX R series

    2. Slowly insert the side view mirror adapter into the scope distal endand push in till the claw inside the side view mirror adapter isengaged with the claw on the scope distal end (this determines therotation direction). If the side view mirror adapter cannot be inserted,

    rotate it so that its mirror turns and ensure that it is fit properly. Rotateuntil the first threaded section of the nut goes beyond the connectionscrew (see Figure 3.13).

    Figure 3.13

    3. After the first threaded section has gone beyond the connectionscrew, rotate the side view mirror adapter while lightly pushing it, andconfirm that the rotation is stopped by engagement of the claw insidethe side view mirror adapter in the mirror adapter lock groove on thescope distal end (see Figure 3.14).

    Figure 3.14

    4. While pushing the nut of the side view mirror adapter toward thescope, turn the nut clockwise so that the second threaded section isengaged with the connection screw. Tighten the nut all the way untilit is stopped (see Figure 3.15).

    Figure 3.15

  • 8/16/2019 Iplex Mx r Manual

    37/92

    Preparation and Inspection

    IPLEX MX R series 32

    5. To detach the side view mirror adapter, reverse the attaching proce-dure.

    Checking loose parts of the side view mirror adapter Check that the parts of the side view mirror adapter are not loos-ened.

    Never use a loose part. Otherwise, the loose part may dropduring use.

    Checking the scope appearance

    • Check that the scope is not deformed. If it is, it would beimpossible to withdraw the scope from the observation target.

    • Check carefully that the fiber of torn external finish is not pro- jected. Otherwise, it may pierce your hand during use.

    1. Check visually that the external finish of the scope and universal cord

    are free of irregularities such as deformation.2. Check that the external finish of the scope, other than the angulationsection, is not loose.

    3.6 Inspection of the LCD monitor

    • Do not touch the LCD connector with a wet hand.

    Checking the LCD cable

    1. Ensure that the LCD cable is free of irregularity such as wire discon-nection and that it is connected securely to the LCD connector (seeFigure 3.16).

    2. Ensure that the LCD monitor can rotate smoothly around the MX Rmain unit and that it can be locked at any position desired (see Fig-ure 3.16).

  • 8/16/2019 Iplex Mx r Manual

    38/92

    Preparation and Inspection

    33 IPLEX MX R series

    Figure 3.16

    Checking the appearance

    1. Check that the LCD monitor is free of irregularities such as thescreen crack and lock section deformation.

    2. Check that the LCD monitor angle can be varied smoothly (see Fig-ure 3.16).

    LCD cable

  • 8/16/2019 Iplex Mx r Manual

    39/92

    Preparation and Inspection

    IPLEX MX R series 34

    3.7 Inspection of the control unit

    Checking the appearance and universal cable

    1. Check that the external finish materials, buttons, joystick and leverare free of irregularities such as crack and deformation.

    2. Ensure that the universal cable is free of irregularities such as cuttingand buckling.

    Figure 3.17

    3.8 Inspection of the basic functions

    Checking the power supply

    1. Press the “ I ” segment of the POWER switch of the MX R main unitand ensure that the POWER indicator on the front panel light up indi-cating that the power is supplied to the instrument (see Figure 3.18).

    I segment: ON

    segment: OFF

    Also ensure that the POWER switch of the LCD monitor isset to ON.

    Joystick

    ZOOM lever

    FRZ/REC button(left/right)

    ANGLE LOCK buttonUniversal cable

    BOOST button

    BRT lever

  • 8/16/2019 Iplex Mx r Manual

    40/92

    Preparation and Inspection

    35 IPLEX MX R series

    Figure 3.18

    Checking the LCD monitor image

    1. Open the shade of the LCD monitor and ensure that the LCD monitordisplays the observation image.

    2. Ensure that the observation image is free of irregularities such asdust and stain. If any irregularity is observed, return to section 3.4,“Inspection of the scope” and restart inspections.

    3. Ensure that the monitor screen display is as shown in Figure 3.19.

    Figure 3.19

    Checking the illumination lighting

    The Illumination emitted from the scope distal end may heatand ignite a nearby object. When discontinuing the use ofthe scope, be sure to set the LIGHT switch on the frontpanel of the case to OFF.

  • 8/16/2019 Iplex Mx r Manual

    41/92

    Preparation and Inspection

    IPLEX MX R series 36

    • Never look into the light emitted from the scope. Otherwise,your eye may be injured.

    1. Ensure that the LIGHT indicator on the top panel is lit. If not, pressthe LIGHT switch to light the indicator.

    2. Check the light at the scope distal end to confirm that the light sourceis turned on.

    Adjusting the white balance

    Adjust the white balance as required by referring to “White bal-ance” in section 4.5, “Menu operation.”In ordinary conditions, this adjustment is not necessary.

    Checking the angulation

    1. Manipulate the joystick slowly and ensure that the angulation sectionis controlled smoothly.

    The angulation movement is interlocked with the angle anddirection of joystick tilting.

    Checking the angulation lock mode

    1. Push in the [ANGLELOCK] button to initiate the lock mode andensure that the current angulation angle is locked even when youremove your finger from the joystick.

    2. Push in the [ANGLELOCK] button again and ensure that the angula-tion lock mode is released.

  • 8/16/2019 Iplex Mx r Manual

    42/92

    Preparation and Inspection

    37 IPLEX MX R series

    3.9 Attaching and detaching of the belts

    When your want to hang the MX R main unit from your shoulder, attach the

    shoulder belt and waist belt. Be careful not to use a shoulder belt and waistbelt other than those designated by Olympus.

    • Never attempt to carry an object other than the MX R main unitusing the shoulder belt and waist belt. Otherwise, the beltsmay be damaged and cause the main unit to drop.

    • Be sure to check that the shoulder belt and waist belt are freeof irregularities such as fiber fray and damaged metal partsbefore use.

    • Do not use the shoulder belt and waist belt in a manner theyare subjected to an excessive load by, for example, swingingthe MX R main unit using them or placing a heavy object onthe instrument.

    • When using the shoulder belt and waist belt, be careful not tohit the MX R main unit against an object.

    • When carrying the MX R main unit on your body, be careful notto bring it in direct contact with your skin. Otherwise, low-tem-

    perature burns of your skin due to the heat of the instrumentmay result.

    • Do not store the MX R main unit by hanging it from something.Otherwise, the belts may be damaged.

    • Be sure to check that the levers on the hooks of the belts arereturned to the original positions. Otherwise, the MX R main

    unit may drop when you attempt to carry it.

    Attaching the belts

    1. While pushing the hook lever of the shoulder belt, engage the hookson the belt holders of the MX R main unit (see Figure 3.20).

  • 8/16/2019 Iplex Mx r Manual

    43/92

    Preparation and Inspection

    IPLEX MX R series 38

    Figure 3.20

    2. Adjust the length of the shoulder belt using its length adjuster (seeFigure 3.21).

    Figure 3.21

    3. Attach the main unit using the shoulder belt (see Figure 3.22).

    Figure 3.22

    Adjuster

  • 8/16/2019 Iplex Mx r Manual

    44/92

    Preparation and Inspection

    39 IPLEX MX R series

    4. Attach the waist belt to the main unit and adjust its length (see Figure3.23).

    Figure 3.23

    Detaching the belts

    When detaching the shoulder belt or waist belt from the mainunit, push and hold the hook lever of each hook on the shoulderor waist belt and disengage the hook from each belt holder of theMX R main unit.

    3.10 Installation of the control unit on themain unit

    The control unit can be attached to the main unit as desired. It can be leftattached to the main unit during carrying as well as during observation (seeFigure 3.24).

    Figure 3.24

  • 8/16/2019 Iplex Mx r Manual

    45/92

    Preparation and Inspection

    IPLEX MX R series 40

    1. Fit the hanger on the side of the control unit into the hanger holder onthe side of the main unit. As there would be difficulties in fitting if thehanger is tilted, be sure to fit the hanger as straight as possible (seeFigure 3.25).

    Figure 3.25

    2. Push in the hanger until your hand stop a click feeling. If the hangeris not pushed in enough, it may tend to slip out later.

    3. When detaching the control unit from the main unit, pull the controlunit straight upward from the main unit.

    • The control unit can be carried together with the main unit, butcare is required not to tilt or swing the main unit during carry-ing. Otherwise, the control unit may detach and drop from themain unit.

    • When placing the main unit together with the control unitattached to it, do not place the main unit in other way than onits side or on its bottom. Otherwise, the control unit and/orscope may be damaged.

    3.11 Installation of the scope and universalcable on the main unit

    Attaching the scope fixing belt

    Attach the scope fixing belt to the grip of the control section (see

    Figure 3.26).

    Hanger

    holder

    Hanger

  • 8/16/2019 Iplex Mx r Manual

    46/92

    Preparation and Inspection

    41 IPLEX MX R series

    Figure 3.26

    Fixing the scope

    The scope can be fixed with the scope fixing belt attached to the

    control unit (see Figure 3.27).

    Figure 3.27

    Fixing the universal cable

    The universal cable can be fixed on the mount on the side panelof the main unit (see Figure 3.28).

    Figure 3.28

    GripControlunit

    Scope fixingbelt

    Universalcable

    Scope fixingbelt

    Scope

    Lock section

  • 8/16/2019 Iplex Mx r Manual

    47/92

    Operation of the Basic Functions

    IPLEX MX R series 42

    Chapter 4 Operation of the BasicFunctions

    This chapter summarizes general steps for the operations of machinery.For more details on the operation, the operators are recommended tostudy from the expert viewpoints.

    Be careful not to have your foot caught by cables including

    the AC adapter power cord, insertion tube and universalcord or pull them with an excessive force. Otherwise, youmay be stumbled or the equipment may be damaged.

    4.1 Turning power ON

    Image display

    Press the [POWER] switch of the MX R main unit. The imagecaptured through the Objective lens will be displayed on the LCDmonitor.

    Illumination ON-OFF

    • The scope distal end becomes relatively hot when the illumi-

    nation is lit. Be careful not to touch the distal end when the illu-mination is on.

    Ensure that the [LIGHT] indicator on the front panel of the MX Rmain unit is lit. The lighted illumination can be turned off asrequired using the [LIGHT] switch on the top panel.

  • 8/16/2019 Iplex Mx r Manual

    48/92

    Operation of the Basic Functions

    43 IPLEX MX R series

    4.2 Insertion of scope and observation

    Holding the control unit and scope

    1. In general, the joystick of the control unit is manipulated with thethumb of the hand gripping the grip of the control unit (see Figure4.1).

    Figure 4.1

    2. Other buttons are also to be manipulate with a finger of the handgripping the grip of the control unit (see Figure 4.1).

    3. Hold the scope with the opposite hand to the hand gripping the gripof the control unit.

    Inserting the scope

    • If, after the side view mirror adapter is attached to the

    IV7620X2 or IV7630X2, the overall observation image is ori-ented to the left or right as shown in Figure 4.2, or the imagerotates or fluctuates while the scope is moved, the side viewmirror may be about to be detached from the scope distal end.

    As continuing the use may cause the side view mirror adapterto drop from the scope, immediately stop using the scope,withdraw it gently and reattach the side view mirror adaptersecurely as described in the attaching procedure. (Figure 4.2).

  • 8/16/2019 Iplex Mx r Manual

    49/92

    Operation of the Basic Functions

    IPLEX MX R series 44

    Figure 4.2

    • Use the scope based on full understanding on the informationgiven in “Important Information – Please Read Before Use” onpage 3. In case of any question, contact Olympus.

    • Do not use the scope in other environmental conditions thanthose specified in “Operating environment” in Chapter 7,“Specifications” in this manual. Otherwise, unexpected acci-dents such as scope damage may result.

    • If any irregularities are found with the scope operation or otheritems during the scope insertion, do not insert the scope anymore. If the angulation is locked presently, press the [ANGLELOCK] button to release the angulation lock, release your fin-ger from the joystick to free the angulation section, and with-draw the insertion tube slowly.

    While observing the monitor image, confirm the insertion direc-tion and insert the scope slowly. Perform angulation as requiredduring insertion. Take care not to push in the scope by force orapply a squeezing or straining force to the insertion tube.

    Angulating the scope

    The scope should be angulated as required for guidance orobservation. For details on the angulation operation, see“Checking the angulation” on page 36.

    Increase the scope looping amount (bending amount)decreases the maximum angulation angle limit of the angu-lation section. To allow the angulation function to manifestits full performance, it is recommended to use the insertiontube in an as straight as possible condition.

    AbnormalNormal

  • 8/16/2019 Iplex Mx r Manual

    50/92

    Operation of the Basic Functions

    45 IPLEX MX R series

    Adjusting the LCD monitor screen brightness

    Press the brightness control buttons of the LCD monitor asrequired to obtain optimum screen brightness.

    If the image contains a source of strong light, stripe-likenoise may be observed above and below it.

    4.3 Adjustments of image freeze, zoom and

    brightnessFreezing the image

    Do not insert or withdraw the scope while the image is beingfrozen.

    Figure 4.3

    1. Press the [FRZ/REC] button on the side of the control unit to freezethe observation image. The LCD monitor displays the freeze indica-tor (F) on the top right of the screen.

    If the [FRZ/REC] button is held depressed for more than 3seconds, image recording will be initiated.

    2. When the observation image is frozen, pressing the [FRZ/REC] but-ton on the side panel of the control unit again or pressing the [LIVE]

  • 8/16/2019 Iplex Mx r Manual

    51/92

    Operation of the Basic Functions

    IPLEX MX R series 46

    button on the top panel of the IPLEX MX R main unit cancels theimage freezing and returns the displayed image to the live image dis-play.

    3. Freezing an image containing violent movement may cause image

    disturbances.

    The image can also be frozen while the monochrome boostfunction is activated. For the monochrome boost function,see “Monochrome boost” on page 48.

    Zooming the image

    1. While the live image is displayed, tilt the [ZOOM] lever on the side

    panel of the control unit toward [T] to zoom into (magnify) the obser-vation image. During zooming, the LCD monitor displays the zoomlevel display for about 3 seconds. While the zoomed image is dis-played, the LCD monitor displays [ZOOM] to indicate that imagezooming is activated.

    Figure 4.4

    2. To return the image to the original size, tilt the [ZOOM] lever toward[W] so that the zoom level indicator displays the minimum level.

    [ZOOM] disappears when the image is returned to the original size.

    Figure 4.5

  • 8/16/2019 Iplex Mx r Manual

    52/92

    Operation of the Basic Functions

    47 IPLEX MX R series

    The image is zoomed using the electronic zoom circuitry. Asa result, the zoomed image may look slightly coarser thanthe original image.

    Adjusting the image brightness

    While the live image is displayed, tilt the [BRT] lever of the con-trol unit toward [ ▲] to brighten the overall image or toward [ ▼] todarken it. When the image brightness is adjusted, the LCD mon-itor displays the brightness level indicator for about 3 seconds.

    Figure 4.6

    If the image brightness is increased to level 6 or more, thelive image becomes a frame-by-frame image because theCCD exposure time is increased. The frame-by-frame dis-play interval increases as the image is dark, and the framesare displayed at about 1-second intervals when the bright-ness level is maximized (level 11).

    Figure 4.7

  • 8/16/2019 Iplex Mx r Manual

    53/92

    Operation of the Basic Functions

    IPLEX MX R series 48

    Monochrome boost

    While the live image is displayed, press the [BOOST] button ofthe control unit to initiate the gain boost display featuring highsensitivity. The live image becomes monochrome during thegain boost display. This function is effective when it is required toobserve the image under high brightness than the standard, forexample when the subject is very dark. Note that the imagenoise may increase under certain observation conditions.Press the [BOOST] button again to return to the standard image.

    The live image is displayed in monochrome when the mono-chrome boost function is activated.

  • 8/16/2019 Iplex Mx r Manual

    54/92

    Operation of the Basic Functions

    49 IPLEX MX R series

    4.4 I mage recording/playback on/from record ingcard (CF card loaded in the CF card adapter)

    Recording the image

    Preparation

    • Never remove the recording card from the RECORDINGCARD slot during recording. Otherwise, the data in therecording card may be destroyed.

    • Be sure to insert the recording card into the RECORDINGCARD slot in the orientation shown in Figure 4.8. Otherwise,the recording card and/or RECORDING CARD slot may bedestroyed or damaged.

    Figure 4.8

    The recording card should always be formatted on the IPLEXMX R main unit. For the formatting procedure, see “2. Format”on page 55.

    Load a CF card designated by Olympus in the CF card adapterand insert this in the RECORDING CARD slot on the side of theIPLEX MX R main unit (see Figure 4.8).

    The following table shows the capacity required for recordingevery image and the number of images that can be recorded inthe CF card provided as standard with the instrument.

    RECORDINGCARD slot

    CF card adapter

    Notch

    Take care of the position of the notch on the CF card adapter.

  • 8/16/2019 Iplex Mx r Manual

    55/92

    Operation of the Basic Functions

    IPLEX MX R series 50

    CF card recording capacity

    When the image file number reaches 9999, attempt torecording another image causes an error and the imagecannot be recorded. In this case, delete existing images inthe CF card or use another CF card to record the image.

    Notes on the image files

    a. The recorded images are saved in folder “\100IV7L1” in therecording card.

    b. Recording an image results in creating file “IV7L????.JPG”in the folder.

    c. “IV7L????” is the filename, and “????” is the 4-digit serialnumber of the filename, which is one of the numbersbetween 0001 and 9999. When an image is recorded, animage file having the serial filename number that is larger byone than the largest serial filename number existing in therecording card. For example, when there are files named“IV7L0001” and ”IV7L0003” in the recording card, the nextrecorded image will be named “IV7L0004”.

    Never remove the recording card from the RECORDINGCARD slot during recording to the card. Otherwise, the data

    in the recording card may be destroyed.

    Press and hold the [FRZ/REC] button of the control unit for morethan 3 seconds to record a still image. When the image isrecorded properly, the LCD monitor displays “RECORDINGCARD **% LEFT” during the still image recording. The LCDmonitor image returns to the live image upon completion of theimage recording.

    • The recording card should be formatted after purchase.

    Recording format Capacity per imageNumber of images(128 MB CF card)

    JPEG Approx. 128 KB Over 900 images

  • 8/16/2019 Iplex Mx r Manual

    56/92

    Operation of the Basic Functions

    51 IPLEX MX R series

    • Recording can be initiated either during the live image displayor frozen image display of the LCD monitor.

    • The still image can be recorded also when the monochromeboost function is activated, but the recorded image is mono-chrome in this case. For the monochrome boost function, see“Monochrome boost” on page 48.

    • This instrument records still images. If recording of a movingimage is required, connect a commercially available VCR tothe video output terminal and record the video on it.

    Playing back the image

    Image playback (image viewing) and played image selection

    Never remove the recording card from the RECORDINGCARD slot during playback from the card. Otherwise, thedata in the recording card may be destroyed.

    Press the [VIEW] button on the front panel of the IPLEX MX Rmain unit. This displays the images of the image file with the

    largest serial filename number recorded in the recording card onthe LCD monitor (view image display). The LCD monitor displaysthe 4-digit serial filename number on the top right of the viewimage display.

    The played image can be selected by pressing the [ ] or [ ]button on the top panel of the IPLEX MX R main unit. Pressingthe [ ] button increments the serial filename number on the topright of the view image display screen and pressing the [ ] but-ton decrements it.

    Figure 4.9

  • 8/16/2019 Iplex Mx r Manual

    57/92

    Operation of the Basic Functions

    IPLEX MX R series 52

    • If the recording card stores no recording image, the viewimage display does not appear even when the [VIEW] button

    is pressed.• If the recording card is not loaded properly in the IPLEX MX Rmain unit, message “RECORDING CARD NOT READY PushENTER” appears when the [VIEW] button is pressed. In thiscase, insert the recording card correctly, press the [ENTER]button and then press the [VIEW] button again.

    Figure 4.10

    • While the view image is displayed, pressing the [LIVE] button

    on the top panel of the IPLEX MX R main unit returns the dis-play to the live image display.

    How to use IPLEX MANAGER

    Review the manual of IPLEX MANAGER before use.

    How to use

    In order to import image files from a strage medium, proceed as fol-lows;Open or cerate the folder for importing the images by clicking the“Open Folder” button in the toolbar.Back to the main window, click the “import” button in the toolbar orselect the appropriate command in the Edit menu.

    1. Select the drive and directory you want to import images from.2. Select “All Importable Standard Files” for the file type.3. There are different import modes available:

    “Copy Source File”: The original image file will be copied to theOLYMPUS IPLEX MANAGER folder.“Move Source File” The original image file will be deleted. The image

  • 8/16/2019 Iplex Mx r Manual

    58/92

    Operation of the Basic Functions

    53 IPLEX MX R series

    is only stored in the OLYMPUS IPLEX MANAGER folder.4. Select the image files you want to import.5. Start importing the selected files by clicking “Import” . To import all

    images from the directory, click “Import All”.6. OLYMPUS IPLEX MANAGER creates thumbnails for the images and

    displays them in the selected folder.

    Figure 4.11

  • 8/16/2019 Iplex Mx r Manual

    59/92

    Operation of the Basic Functions

    IPLEX MX R series 54

    4.5 Menu operation

    The displayed menus are different between the live imagedisplay and view image (played image) display.

    Press the [MENU] button on the top panel of the IPLEX MX R main unit todisplay a menu on the LCD monitor screen for use in setup and control ofvarious functions. Pressing the [MENU] button again causes the menu todisappear.

    Live image display menu and its functions The menu recalled on the live image display (the main menu)can be used for the following setups.

    Figure 4.12

    1. DISPLAY Select whether or not the date, time and [OLYM-PUS] logo are displayed on the LCD monitorscreen.

    2. FORMAT Select when formatting a recording card.

    3. W.BALANCE

    (White balance)

    Select when adjusting the white balance. The

    white balance adjustment is usually not required.4. DATE/TIME Select when setting the date and time.

    5. LANGUAGE Select the language used in the menu display.The available options include [ENGLISH], [GER-MAN], [FRENCH], [SPANISH] and [JAPANESE].

  • 8/16/2019 Iplex Mx r Manual

    60/92

    Operation of the Basic Functions

    55 IPLEX MX R series

    1. DISPLAY

    Press the [ ] or [ ] button to move the marking on [1. DIS-PLAY] and press the [ENTER] button.

    Press the [ ] or [ ] button to select one of options (ALL), (NOLOGO) and (OFF) so that it blinks, and press the [ENTER] but-ton.

    Figure 4.13

    2. FORMAT

    • Never remove the recording card during formatting.• Never turn IPLEX MX R off during formatting a recording card.• Formatting a recording card results in deleting all of the image

    data recorded in it.Select this item to format a recording card. Note that formatting arecording card deletes all of the existing image data recorded init.While the live image is displayed, press the [MENU] button todisplay the menu.Press the [ ] or [ ] button to move the marking on [2. FOR-MAT] and press the [ENTER] button.Press the [ ] or [ ] button to select either option (OK) or (CAN-

    CEL) so that it blinks, and press the [ENTER] button.

    (ALL) The date, time and [OLYMPUS] logo are displayed.

    (NO LOGO) Only the date and time are displayed.

    (OFF) None of the date, time and [OLYMPUS] logo aredisplayed.

  • 8/16/2019 Iplex Mx r Manual

    61/92

    Operation of the Basic Functions

    IPLEX MX R series 56

    Figure 4.14

    3. WHITE BALANCE

    • Do not adjust the white balance while the image is being fro-zen.

    • This adjustment is not necessary in ordinary conditions.

    Select an item to adjust the white balance. The white balanceshould be adjusted by capturing the image of a white subject(paper). To perform white balance adjustment, be sure to turn onthe scope illumination and choose a place where there is noother light than the illumination emitted from the distal end of the

    scope.Press the [ ] or [ ] button to move the marking on [3.WHITE BALANCE] and press the [ENTER] button.Closely point the scope tip at a white subject and press the [ ]or [ ] button to select either options (OK) or (CANCEL) so that itblinks, and press the [ENTER] button.

    (OK) Select to execute formatting.

    (CANCEL) Select to return to the main menu.

    (OK) Select to adjust the white balance.

    (CANCEL) Select to return to the main menu.

  • 8/16/2019 Iplex Mx r Manual

    62/92

    Operation of the Basic Functions

    57 IPLEX MX R series

    Figure 4.15

    4. DATE/TIME

    Select this item to set the date and time.

    Press the [ ] or [ ] button to move the marking on [4. DATE/TIME] and press the [ENTER] button.When four items of [YEAR], [MONTH], [DAY], [HOUR] and[MINUTE] are displayed, set the desired figure in each itemusing the [ ] or [ ] button. Pressing the [ENTER] button movesthe blinking item to the next item.

    After entering the figure of [MINUTE], press the [ ] or [ ] but-ton to select either options (OK) or (RETRY) so that it blinks, andpress the [ENTER] button.

    Figure 4.16

    (OK) Select to enter the displayed date and time inmemory.

    (RETRY) Select to return the blinking item to [YEAR]. Nowyou can restart setting the date and time again.

  • 8/16/2019 Iplex Mx r Manual

    63/92

    Operation of the Basic Functions

    IPLEX MX R series 58

    To abort the date and time setup in the middle, press eitherthe [LIVE] or [MENU] button.

    5. LANGUAGE

    Select this item to select the menu display language.

    Press the [ ] or [ ] button to move the marking on [5. LAN-GUAGE] and press the [ENTER] button.Press the [ ] or [ ] button to select one of options (ENGLISH),(GERMAN), (FRENCH), (SPANISH) and (JAPANESE) so that it

    blinks, and press the [ENTER] button. Two options are providedfor (ENGLISH) according to the date display format.

    Figure 4.17

    (ENGLISH M/D/Y) English. The date is displayed in the M/D/Yformat.

    (ENGLISH D/M/Y) English. The date is displayed in the D/M/Yformat.

    (GERMAN D/M/Y) German. The date is displayed in the D/M/Yformat.

    (FRENCH D/M/Y) French. The date is displayed in the D/M/Yformat.

    (SPANISH D/M/Y) Spanish. The date is displayed in the D/M/Yformat.

    (JAPANESE Y/M/D) Japanese. The date is displayed in the Y/M/Dformat.

  • 8/16/2019 Iplex Mx r Manual

    64/92

    Operation of the Basic Functions

    59 IPLEX MX R series

    View image (played image) display menu and its func-tions

    The menu recalled by pressing the [MENU] button on the viewimage display can be used for deleting recorded images. Press-ing the [MENU] button again causes the menu to disappear.

    Erasing recorded images

    • Never remove the recording card from the RECORDINGCARD slot during deletion. Otherwise, the data in the

    recording card may be destroyed.• Never turn IPLEX MX R off during image deletion.

    While the view image is displayed, press the [MENU] button todisplay the menu.

    Press the [ ] or [ ] button to select one of options (ALLIMAGES), (IMAGE) and (OFF) so that it blinks, and press the[ENTER] button.When (ALL IMAGES) or (IMAGE) is selected, a submenu for

    selection of (OK) or (CANCEL) is displayed. Press the [ ] or [ ]button to select either option (OK) or (CANCEL) so that it blinks,and press the [ENTER] button.

    (ALL IMAGES) Select to delete all images in therecording card.

    (DELETE ALL IMAGES)

    (OK) Select to execute image deletion.

    (CANCEL) Select to return to the view imagedisplay.

    (IMAGE) Select to delete only the imagebeing displayed.

    (DELETE IMAGE)

    (OK) Select to execute image deletion.

    (CANCEL) Select to return to the view imagedisplay.

    (CANCEL) Select to return to the view imagedisplay.

  • 8/16/2019 Iplex Mx r Manual

    65/92

    Operation of the Basic Functions

    IPLEX MX R series 60

    Figure 4.18

  • 8/16/2019 Iplex Mx r Manual

    66/92

    Operation of the Basic Functions

    61 IPLEX MX R series

    4.6 Remaining battery power

    During battery-powered operation of IPLEX MX R, the LCD monitor dis-

    plays the remaining battery power indicator on the top left of the screen.The reference remaining battery capacities are displayed as follows.

    • The remaining battery power percentages above are standardvalues assuming the use under the normal temperature of27 °C (approx. 70 °F). They are slightly different during useunder lower temperatures.

    • If the battery continues to be used after battery voltage dropcaution indication (5) is displayed, the IPLEX MX R will be shutdown automatically to protect the battery against excessive

    discharge.• The remaining battery power can also be checked on the bat-

    tery. To check it, press the [CHECK] button on the battery. Thegreen LEDs light according to the remaining battery power.For details, refer to the instruction manual for your battery.

    • Even when two of the green remaining power indicator LEDson the battery are lit, the IPLEX MX R may be shut down auto-matically when that battery is used. This is the measure per-formed by the IPLEX MX R to protect the battery againstexcessive discharge. It occurs more often when the ambienttemperature drops, but it is not a malfunction. If this happens,recharge the battery before reusing it.

    1 Remaining about 50% or more.

    2 Remaining about 5% to 50%.

    3 Remaining about 2% to 5%.

    4Remaining about 1% to 2%.This indicator is flashes.

    5

    Remaining about 1% to 2%.This indicator is flashes.No image recording will be possible.Replace with the battery that has beencharged with the charger.

  • 8/16/2019 Iplex Mx r Manual

    67/92

    Operation of the Basic Functions

    IPLEX MX R series 62

    • The remaining battery power is not displayed during the ACadapter-powered operation.

    • When long hours of battery-powered operation are expectedor when using the instrument in a cold weather, it is recom-mended to prepare charged batteries as spares.

    • When the battery operation time becomes extremely short, itis recommended to replace the battery with a brand-new bat-tery.

    • The MX R main unit is not provided with charging capability. Tocharge the battery, use the optional battery charger (JL-2PLUS).

    4.7 Battery replacement

    • To prevent electric shock, make sure to set the power switchto “ O ” (OFF) before opening the battery compartment door.

    • Be careful not to injure yourself with the battery compartmentdoor during the battery replacement.

    • Never use a battery other than the one designated by Olym-pus. Otherwise, failure of the instrument may not only lead to amalfunction but also a fire.

    • Be careful not to leave a foreign object in the battery compart-ment after the battery replacement. Otherwise, a fire or mal-function may result.

    • Be careful not to drop a battery during replacement.

    Replacing the internal battery

    1. Set the power switch of the IPLEX MX R main unit to “ O ” (OFF).2. Open the battery compartment door by flipping up the latch of the

    door.

  • 8/16/2019 Iplex Mx r Manual

    68/92

    Operation of the Basic Functions

    63 IPLEX MX R series

    3. Push in the old battery until it clicks; it will then come out automati-cally.

    Figure 4.19

    4. While holding the battery compartment door open, pull out the oldbattery.

    5. Insert the new battery as described in “Supplying power from theinternal battery” in section 3.3, “Preparation of power supply.”

    4.8 Withdrawal of the scope

    • Do not withdraw the scope while its angulation is locked orwhile your finger is placed on the joystick. Otherwise, thescope and/or observation target may be damaged.

    • If the scope is caught by something during withdrawal, turn thecontrol unit gently while continuing the withdrawal. Do notattempt to withdraw the scope by force, as this may result indamage to the scope and/or examination target.

    • The scope distal end is very hot immediately after use in ahigh-temperature atmosphere. Do not touch it directly to pre-vent burns.

    Releasing the angulation lock

    If angulation lock is activated, press the [ANGLE/LOCK] buttonto release it.

    Withdrawing the scope

    Remove your finger away from the joystick and withdraw thescope gently while observing it.

  • 8/16/2019 Iplex Mx r Manual

    69/92

    Operation of the Basic Functions

    IPLEX MX R series 64

    4.9 Turning power OFF

    Press the [POWER] button of the MX R main unit to turn it OFF.

    4.10 Cleaning of the scope

    • After withdrawing the scope, immediately proceed to cleaning

    of the scope. If time elapses after withdrawal, adhesion ofstain or corrosion of equipment may result.• Do not use a hard cloth or hard brush for cleaning the scope.

    Otherwise, the scope may be damaged.

    1. If a foreign object such as dust is attached to the scope, wipe it awaywith a clean, soft cloth.

    2. If a liquid such as wastewater or machine oil is attached to the scope,first wipe with a soft cloth or cotton, and wash well using a neutraldetergent solution and pieces of gauze. Then wipe it with a piece ofsoft gauze moistened with clean water, wipe off the moisture well anddry the scope.

  • 8/16/2019 Iplex Mx r Manual

    70/92

    Operation of the Basic Functions

    65 IPLEX MX R series

    4.11 Storage in the case

    Store in the order of: Main unit Control unitScope

    Figure 4.20

    Figure 4.21

    • Before storing the main unit in the case, be sure to remove thebattery and turn the main unit OFF. Otherwise, rise of the tem-perature may lead to fire ignition.

    • Always store the battery and AC adapter below the controlunit.

    Control unit

    Scope IV7620X2: wound by 1-1/2 to 2 times IV7630X2: wound by 2-1/2 to 3 times

    Pocket section

    Main unit

    Internal lid

    Charger

    AC adapter

    Battery

  • 8/16/2019 Iplex Mx r Manual

    71/92

    Operation of the Basic Functions

    IPLEX MX R series 66

    • Wind the scope by 2-1/2 or 3 times to form a loop. Store thelower half of the loop inside the pocket and fix the upper halfon three positions using the Velcro tapes.

    • Be sure to put the distal end of the scope in the pocket.• Do not store the scope together with the side view mirror

    adapter attached to it.• Check that the latch is locked securely. Otherwise, the top

    cover of the case may open during transport.• When closing the top cover, be careful not to have your hand

    or a cable caught by it.• When storing the main unit in the case, be careful not to have

    the scope caught by parts of the case.• When returning the main unit in the case, open the case in a

    stable place before proceeding to storage.• Use only the designated case. Otherwise, the scope and/ormain unit may be damaged or malfunction.

  • 8/16/2019 Iplex Mx r Manual

    72/92

    Strage Precautions

    67 IPLEX MX R series

    Chapter 5 Storage Precautions Store the equipment in normal conditions in a room under normal tempera-ture and normal humidity. Avoid storing it in a place subjected to direct sun-light or radiations.

    Do not apply excessive bending, straining or squeezingforce to any cord or cable during storage. Otherwise, wiredisconnection in the cable or cord may lead to a fire or elec-tric shock accident.

    Do not store the equipment in an environment subjected tohigh temperature, high humidity, dust and fine particles, or in aplace exposed to direct sunlight or radiations. Otherwise, theequipment malfunction may result.

    • Even during storage, do not handle the equipment violently by,for example, hitting the case against an object. Otherwise, theequipment malfunction may result.

    1. Turn the instrument OFF and remove the battery and AC adapter fromit.

    2. Store the instrument in a clean, dry, stable position.

  • 8/16/2019 Iplex Mx r Manual

    73/92

    Troubleshooting

    IPLEX MX R series 68

    Chapter 6 Troubleshooting

    If any irregularity is observed with the instrument, immedi-ately turn it OFF and stop using it. Otherwise, malfunction aswell as fatal or serious injuries to the users may result.

    If the instrument is visible damaged, does not function as expected or isfound to have irregularities during the inspection as described in Chapter3, “Preparation and Inspection,” do not use the instrument. Contact Olym-

    pus.Some problems that appear to be malfunctions may be correctable byreferring to Section 6.1, “Troubleshooting guide.” If the problem cannot beresolved by the described remedial action, stop using the instrument andsend it to Olympus for repair.Olympus does not repair accessory parts because they are consumableitems. If an accessory part fails or becomes damaged, contact Olympus topurchase a replacement.

  • 8/16/2019 Iplex Mx r Manual

    74/92

    Troubleshooting

    69 IPLEX MX R series

    6.1 Troubleshooting guide

    Error messages

    Irregularitydescription

    Screendisplay

    Possible cause Solution

    Entering thebutton is notaccepted.

    PROCESSORERROR

    Self diagnostic functionperformed.

    Turn off and on thepower. If error messagestill exists, contact to theOLYMPUS servicecenter.

    Joystick articula-tion becomesheavier.

    TURN OFFPOWERARTICULA-TION ERROR

    Overload is added ontothe articulationmechanism.

    Reduce the loop situa-tion of insertion tube andrelease the angle of

    joystick. Then turn offand on the power.

    Messagedisplayed whenimage recording orplayback isimpossible.

    RECORDINGCARD NOTREADY

    An attempt is made toaccess the recordingcard while it is notinserted, or the recordingcard is removed duringoperation.

    Insert the recording cardand try again.

    RECORDINGCARD ERROR

    The recording card is notformatted, or an attemptis made to access adestroyed recording card.

    Format the recordingcard.

    RECORDINGCARD FULL

    Not enough memory isavailable.

    Delete unnecessaryimages or replace withnow recording card.

    RECORDINGCARD FULL

    An attempt is made torecord an image file whilethe serial filename num-ber has already reachedthe maximum number.

    Format the recordingcard.

    (No message) Format type is different. Chose the FAT formatthen format the recordingcard on PC. Then formatthe recording card on theIPLEX MX R.

    Messagedisplayed whenimage playback isimpossible

    FORMAT MISSMATCH

    TV format of image datadoes not adapted toIPLEX MX R.

    IPLEX MX R is not possi-ble to display the differentTV format.

  • 8/16/2019 Iplex Mx r Manual

    75/92

    Troubleshooting

    IPLEX MX R series 70

    Irregularities under normal use

    Irregularitydescription Possible cause Solution

    The side viewmirror adaptercannot beattached to thescope.(when the IV7620X2/ IV7630X2 is used)

    A foreign object is attached to thescope distal end (in a positionbeyond the side view mirroradapter lock groove) and/or insidethe side view mirror adapter.

    Clean them with clean gauze orcotton swab.

    The exclusive side view adapter isnot in use.

    Use the exclusive adapter.

    The nut is not turned in the correctdirection.

    Retry by following the correct pro-cedure in the instruction manual.

    The claw on the scope distal endis not engaged with the claw insidethe side view mirror adapter.

    Retry by following the correct pro-cedure in the instruction manual.

    The side view mir-ror adapter can-not be detachedfrom the scope.(when the IV7620X2/ IV7630X2 is used)

    The nut of the side view mirroradapter is not turned in the correctdirection.

    Retry by following the correct pro-cedure in the instruction manual.

    There is dirt or debris in the nutmechanism.

    Clean the nut.

    The power fails tocome on.

    The AC adapter is not connected. Connect it properly.

    The battery is not installed Install it properly.The battery is not charged. Use a fully charged battery.The power is not set to ON. Set the [POWER] button of the MX

    R main unit to ON.A non-designated AC adapter isconnected.

    Use the designated AC adapter.(MAJ-1376N or P)

    A non-designated battery isinstalled.

    Use the designated battery.(NP-L7S type)

    Image is not

    displayed.

    The LCD monitor is connected

    improperly.

    Connect it properly.

    The LCD monitor is OFF. Turn it ON.Image is notsharp.

    The Objective lens is dirty. Wipe with clean gauze or a cottonswab.

    The side view mirror adapter isattached improperly. (when theIV7620X2/IV7630X2 is used)

    Attach it properly.

    The externally connected monitoris adjusted improperly (only whenthe externally connected monitor ismounted).

    Adjust it properly.

  • 8/16/2019 Iplex Mx r Manual

    76/92

    Troubleshooting

    71 IPLEX MX R series

    Image brightnessis not optimum.

    The objective or lighting lens isdirty.

    Wipe with clean gauze or a cottonswab.

    The externally connected monitoris adjusted improperly (only whenthe externally connected monitor ismounted.

    Adjust it properly.

    The automatic bright adjustmentor long-time exposure is setimproperly.

    Adjust them properly.

    Colors areincorrect.

    The white balance is adjustedimproperly.

    Re-adjust the white balance.

    Irregularitydescription Possible cause Solution

  • 8/16/2019 Iplex Mx r Manual

    77/92

    Troubleshooting

    IPLEX MX R series 72

    6.2 Returning the instrument for repair

    Olympus is not liable for any injury or damage which occursas a result of repairs attempted by non-Olympus personnel.

    Olympus will not repair an instrument contaminated by nox-ious substances.

    Before returning the instrument for repair, contact Olympus. With theinstrument, include a description of malfunction or damage and the nameand telephone number of the individual at your location who is most famil-iar with the problem. Also include a repair purchase order.

    Malfunctions and failures occurring before expiration of the warranty periodwill be repaired free of charge according to the warranty terms and condi-tions described on the warranty card. Be sure to attach the warranty cardwhen returning the instrument for repair. Repair will be charged if the war-

    ranty card is not attached together. The freight fees should be paid by theuser even in case of repair free of charge.

  • 8/16/2019 Iplex Mx r Manual

    78/92

    Specifications

    73 IPLEX MX R series

    Chapter 7 Specifications

    Operating environmentAmbienttemperature

    Insertion tube In air : 25 +80°C degreeUnder water: +10 +30°C degree

    Other parts In air : 0 40°C degree

    Atmo-sphericpressure

    Insertion tube In air : Normal pressure (1013 hPa)Under water: 1013 1317hPa

    Other parts In air: Normal pressure (1013hPa)

    Operatingenvironment

    Relative humidity 15% to 90%

    Can’t use under environment of heavyradiation etc. not specified in this manual.

    Liquidresistance

    Insertion tube No trouble even when machine oil ,diesel oil or 5% saline is attached.

    Other parts No trouble even when machine oil ,diesel oil or 5% saline is attached to theexternal finish.

    Water proofing

    Insertion tube Can be used in water.

    Other parts Neither waterproof nor splash proof.

  • 8/16/2019 Iplex Mx r Manual

    79/92

    Specifications

    IPLEX MX R series 74

    Specifications (The specifications of the side view mirroradapter is provided separately.)

    General Weight Without external battery case.4.6 kg(With LCD, a battery and belts)

    With battery case5.4 kg(With LCD, batteries and belts)

    Insertion tubeOptical system

    Direction ofview

    Direct viewing

    Depth of field IV7415X2, IV7430X2: 12 50