IPEC ENGINEERING (M) SDN BHD (Company Reg: 677556K)
SALES, FIELD SERVICES, TRAINING, PROJECT MANAGEMENT AND ASSET MANAGEMENT
COMPREHENSIVE HIGH VOLTAGE
NON-DESTRUCTIVE TESTING
HIGH VOLTAGE DIAGNOSTIC TECHNOLOGY
.
IPEC ENGINEERING (M) SDN BHD (reg 677556) No 7-B, Jalan USJ 21/5, Subang Jaya, Selangor D.E. 47620 Malaysia
T +6 03 8023 1912 F +6 03 8023 7912 [email protected] www.my-ipec.com.my
HV CONSUMERS
• RAPID KL • Lynas Malaysia • Malaysia Airport • Lafarge • YTL • Perwaja Steel
OIL & GAS
• Petronas Offshore • Petronas Gas • Petronas Carigali • Petronas Methanol Labuan • Petronas Ethylene • Petronas CUF • Petronas Ammonia • Petronas Fertilizer • Petronas Penapisan • Petronas TCOT • Petronas BASF • Shell
UTILITY
• TNB • Kapar Energy Venture • Kenerong Minihydro • Jimah Energy Venture • Lumut Power Plant • Tanjung Bin Power Plant • Kuala Langat Power Plant • Pahlawan Power Plant • Panglima Power Plant • Perai Power Plant • Makhostia • Sarawak Energy • Bakun Power Plant • Janamanjung • Lumut Power Plant
OUR CUSTOMERS
OEM
• Siemens • ABB • GE • Alstom • EWT • MTM • Technip
INSTRUMENT TRANSFORMER(CT, CVT, IVT)
• Thermography – ONLINE • Insulation Power Factor (Dielectric dissipation factor / Tan Delta Measurement) – OFFLINE • Online Partial Discharge (Sealing ends) – ONLINE • Ultrasound - ONLINE
HV MOTORS
• Thermography – ONLINE • Insulation Power Factor (Dielectric dissipation factor / Tan Delta Measurement) – OFFLINE • Online Partial Discharge – ONLINE • Vibration Analysis – ONLINE • Motor Current Analysis - ONLINE
LV SWITCHBOARD, BUS DUCT, FUSES, MCB
• Thermography – ONLINE
HV TRANSFORMER
• Insulation Power Factor (Dielectric dissipation factor / Tan Delta Measurement) – OFFLINE • Dielectric Frequency Response (DFR) / Frequency Dielectric Spectroscopy (FDS) -
OFFLINE • Winding resistance - OFFLINE • Turn ratio – OFFLINE • Frequency Response Analysis – OFFLINE • Insulation Resistance - OFFLINE • Online Tap Changer – ONLINE • Thermography – ONLINE
HV SWITCHGEAR
• Online Circuit Breaker Analyzer - ONLINE / OFFLINE • Online Partial Discharge – ONLINE • Insulation Power Factor (Dielectric dissipation factor / Tan Delta Measurement) – OFFLINE • Thermography - ONLINE • Ultrasound - ONLINE
HV CABLE
• Online Partial Discharge – ONLINE • Insulation Power Factor (Dielectric dissipation factor / Tan Delta Measurement) – OFFINE • VLF Tan Delta Measurement - OFFLINE • Sheath Test - OFFLINE • Thermography - ONLINE
Testing Monitoring Service (Switzerland)
1st Trip Circuit Breaker (Profile P3)
Circuit Breaker Analyser (Ireland)
Infrared Window (Australia)
VPT CAP-T
Transformer Monitoring System
Cable Testing and Diagnostic
Delta T Alert 24x7 Online Monitoring