AC Alternating Current ACK ACKnowledge ADSL Asymmetric Digital
Subscriber Line ALG Application Level Gateway ANSI American
National Standards Institute ARP Address Resolution Protocol AS
Autonomous System AUX Auxiliary BGP Border Gateway Protocol BGP4
Border Gateway Protocol - version 4 BGP4+ Multiprotocol Extensions
for Border Gateway Protocol - version 4 bit/s bits per second *bps
BPDU Bridge Protocol Data Unit BRI Basic Rate Interface CC
Continuity Check
III
CDP Cisco Discovery Protocol CFM Connectivity Fault Management CIDR
Classless Inter-Domain Routing CIR Committed Information Rate CIST
Common and Internal Spanning Tree CLNP ConnectionLess Network
Protocol CLNS ConnectionLess Network System CONS Connection
Oriented Network System CRC Cyclic Redundancy Check CSMA/CD Carrier
Sense Multiple Access with Collision Detection CSNP Complete
Sequence Numbers PDU CST Common Spanning Tree DA Destination
Address DC Direct Current DCE Data Circuit terminating Equipment
DHCP Dynamic Host Configuration Protocol DIN Deutsche Industrie
Normen DIS Draft International Standard/Designated Intermediate
System DNS Domain Name System DR Designated Router DSAP Destination
Service Access Point DSCP Differentiated Services Code Point DTE
Data Terminal Equipment DVMRP Distance Vector Multicast Routing
Protocol E-Mail Electronic Mail EAP Extensible Authentication
Protocol EAPOL EAP Over LAN EFM Ethernet in the First Mile EPU
External redundant Power Unit ES End System FAN Fan Unit FCS Frame
Check Sequence FDB Filtering DataBase FQDN Fully Qualified Domain
Name FTTH Fiber To The Home GBIC GigaBit Interface Converter GSRP
Gigabit Switch Redundancy Protocol HMAC Keyed-Hashing for Message
Authentication IANA Internet Assigned Numbers Authority ICMP
Internet Control Message Protocol ICMPv6 Internet Control Message
Protocol version 6 ID Identifier IEC International Electrotechnical
Commission IEEE Institute of Electrical and Electronics Engineers,
Inc. IETF the Internet Engineering Task Force IGMP Internet Group
Management Protocol IP Internet Protocol IPCP IP Control Protocol
IPv4 Internet Protocol version 4 IPv6 Internet Protocol version 6
IPV6CP IP Version 6 Control Protocol IPX Internetwork Packet
Exchange ISO International Organization for Standardization ISP
Internet Service Provider IST Internal Spanning Tree L2LD Layer 2
Loop Detection LAN Local Area Network LCP Link Control Protocol LED
Light Emitting Diode LLC Logical Link Control LLDP Link Layer
Discovery Protocol LLQ+3WFQ Low Latency Queueing + 3 Weighted Fair
Queueing LSP Label Switched Path LSP Link State PDU LSR Label
Switched Router MA Maintenance Association MAC Media Access Control
MC Memory Card MD5 Message Digest 5 MDI Medium Dependent Interface
MDI-X Medium Dependent Interface crossover MEP Maintenance
association End Point MIB Management Information Base MIP
Maintenance domain Intermediate Point
IV
MLD Multicast Listener Discovery MRU Maximum Receive Unit MSTI
Multiple Spanning Tree Instance MSTP Multiple Spanning Tree
Protocol MTU Maximum Transfer Unit NAK Not AcKnowledge NAS Network
Access Server NAT Network Address Translation NCP Network Control
Protocol NDP Neighbor Discovery Protocol NET Network Entity Title
NLA ID Next-Level Aggregation Identifier NPDU Network Protocol Data
Unit NSAP Network Service Access Point NSSA Not So Stubby Area NTP
Network Time Protocol OADP Octpower Auto Discovery Protocol OAM
Operations,Administration,and Maintenance OSPF Open Shortest Path
First OUI Organizationally Unique Identifier packet/s packets per
second *pps PAD PADding PAE Port Access Entity PC Personal Computer
PCI Protocol Control Information PDU Protocol Data Unit PICS
Protocol Implementation Conformance Statement PID Protocol
IDentifier PIM Protocol Independent Multicast PIM-DM Protocol
Independent Multicast-Dense Mode PIM-SM Protocol Independent
Multicast-Sparse Mode PIM-SSM Protocol Independent Multicast-Source
Specific Multicast PoE Power over Ethernet PRI Primary Rate
Interface PS Power Supply PSNP Partial Sequence Numbers PDU QoS
Quality of Service RA Router Advertisement RADIUS Remote
Authentication Dial In User Service RDI Remote Defect Indication
REJ REJect RFC Request For Comments RIP Routing Information
Protocol RIPng Routing Information Protocol next generation RMON
Remote Network Monitoring MIB RPF Reverse Path Forwarding RQ
ReQuest RSTP Rapid Spanning Tree Protocol SA Source Address SD
Secure Digital SDH Synchronous Digital Hierarchy SDU Service Data
Unit SEL NSAP SELector SFD Start Frame Delimiter SFP Small Form
factor Pluggable SFP+ Enhanced Small Form factor Pluggable SML
Split Multi Link SMTP Simple Mail Transfer Protocol SNAP
Sub-Network Access Protocol SNMP Simple Network Management Protocol
SNP Sequence Numbers PDU SNPA Subnetwork Point of Attachment SPF
Shortest Path First SSAP Source Service Access Point STP Spanning
Tree Protocol TA Terminal Adapter TACACS+ Terminal Access
Controller Access Control System Plus TCP/IP Transmission Control
Protocol/Internet Protocol TLA ID Top-Level Aggregation Identifier
TLV Type, Length, and Value TOS Type Of Service TPID Tag Protocol
Identifier TTL Time To Live UDLD Uni-Directional Link
Detection
V
UDP User Datagram Protocol ULR Uplink Redundant UPC Usage Parameter
Control UPC-RED Usage Parameter Control - Random Early Detection
VAA VLAN Access Agent VLAN Virtual LAN VRRP Virtual Router
Redundancy Protocol WAN Wide Area Network WDM Wavelength Division
Multiplexing WFQ Weighted Fair Queueing WRED Weighted Random Early
Detection WS Work Station WWW World-Wide Web XFP 10 gigabit small
Form factor Pluggable
kB( ) 1kB( )1MB( )1GB( )1TB( ) 1024
1024 1024 1024
VI
incorrect”
4-4
login: operator Password: …1 No password is set. Please set
password! …2 Copyright (c) 2010-20XX ALAXALA Networks Corporation.
All rights reserved. > …3
1.
set exec-timeout
5
20
2.
> enable # configure (config)# hostname "OFFICE1"
!OFFICE1(config)# end !OFFICE1# copy running-config startup-config
Do you wish to copy from running-config to startup-config? (y/n): y
OFFICE1#
61
5-3
OFFICE1# configure OFFICE1(config)# system l2-table mode 2 Please
execute the reload command after save, because this command becomes
effective after reboot. !OFFICE1(config)# end !OFFICE1# copy
running-config startup-config Do you wish to copy from
running-config to startup-config? (y/n): y @OFFICE1# reload Restart
OK? (y/n): y
[Tab]
5.2.2
5-5 ?
> show vlan ? <VLAN ID list> - [1-4094] ex. "5", "10-20"
or "30,40" <Display option> - {detail | list | summary}
channel-group-number - Display the VLAN information specified by
channel-gro
up-number id - A part of VLAN ID mac-vlan - Display the MAC VLAN
information port - Display the VLAN information specified by port
number
<cr> > show vlan
1.
Tab?
63
5-6 (gigabitethernet )
(config)# interface gigabtiethernet 0/1 [Enter] ^ Error: Invalid
parameter. (config)#
5-7 (duplex )
(config)# interface gigabitethernet 0/1 (config-if)# duplex [Enter]
^ Error: Missing parameter. (config-if)#
5.2.4
> sh ip ar [Enter]
>
5-9
> ping 192.168.100.2 …1 PING 192.168.100.2 (192.168.100.2): 56
data bytes 64 bytes from 192.168.100.2: icmp_seq=0 ttl=128
time=3.783 ms 64 bytes from 192.168.100.2: icmp_seq=1 ttl=128
time=2.401 ms 64 bytes from 192.168.100.2: icmp_seq=2 ttl=128
time=2.335 ms 64 bytes from 192.168.100.2: icmp_seq=3 ttl=128
time=2.019 ms ^C ----192.168.100.2 PING Statistics---- 4 packets
transmitted, 4 packets received, 0.0% packet loss round-trip
min/avg/max = 2.019/2.634/3.783 ms > > …2 > ping
192.168.100.2 …3 64 bytes from 192.168.100.2: icmp_seq=0 ttl=128
time=3.783 ms 64 bytes from 192.168.100.2: icmp_seq=0 ttl=128
time=3.783 ms 64 bytes from 192.168.100.2: icmp_seq=1 ttl=128
time=2.401 ms 64 bytes from 192.168.100.2: icmp_seq=2 ttl=128
time=2.335 ms 64 bytes from 192.168.100.2: icmp_seq=3 ttl=128
time=2.019 ms ^C ----192.168.100.2 PING Statistics---- 4 packets
transmitted, 4 packets received, 0.0% packet loss round-trip
min/avg/max = 2.019/2.634/3.783 ms >
64
5.
> ping 192.168.100.3 …4 64 bytes from 192.168.100.3: icmp_seq=0
ttl=128 time=3.783 ms 64 bytes from 192.168.100.3: icmp_seq=0
ttl=128 time=3.783 ms 64 bytes from 192.168.100.3: icmp_seq=1
ttl=128 time=2.401 ms 64 bytes from 192.168.100.3: icmp_seq=2
ttl=128 time=2.335 ms 64 bytes from 192.168.100.3: icmp_seq=3
ttl=128 time=2.019 ms ^C ----192.168.100.3 PING Statistics---- 4
packets transmitted, 4 packets received, 0.0% packet loss
round-trip min/avg/max = 2.019/2.634/3.783 ms >
1. 192.168.100.2 ping
2.↑
↑ping 192.168.100.2 interval 2 count 1 packetsize 120
Enter
CLI CLI
5-4 CLI CLI
CLI
set
show users
adduser CLI
Ctrl U
Ctrl W
!> show sysversion
sys
save
no-flash
set
exit
5-10
(config)# spanning-tree mst 5 [?] configuration - Configure the
common information used by each MST ins
tance of multiple spanning tree, and enter MST config uration
mode
forward-time - Specify the time which state changes take to a
bridge interface
hello-time - Specify a BPDU transmitting interval max-age - Specify
the maximum time holding the received protoco
l information max-hops - Specify the maximum number of hop about
BPDU root - Specify a root transmission-limit - Specify the maximum
number of BPDU which can be trans
mitted for one second
(config)# aaa authentication mac-authentication <List name> -
Specify the RADIUS server list name 1 to 32 character s default -
Specify default mac authentication mechanism end-by-reject -
Specify end-by-reject mechanism (config)# aaa authentication
mac-authentication de ⇒ group - Specify mac authentication
mechanism using RADIUS pro tocol local - Specify mac authentication
mechanism using local pass word
<List name> "de "de
<List name> "default"
"default" "default"
5-13
<List name> "device" <List name>
"default" "device"
<List name>
5-14
# password <user name> - Specify the user name or enable-mode
<cr> #
"<user name>"
"enable-mode"
4
5-15
switchport-backup "startup-active-port-selection" 24
"startup-active-port-sel"
5-18 <cr> ip access-list extended
(config-ext-nacl)# permit ip any host <PARAMs:input format> -
permit <protocol> {<source ipv4> <source ipv4
wildcar d> | host <source ipv4> | any} [*1]
{<destination ipv 4> <destination ipv4 wildcard> | host
<destination ip v4> | any} [*2][*3][*4] {[tos <tos>]
[precedence <pre cedence>] | dscp <dscp>} [vlan
<vlan id>] [user-prior ity <priority>] NOTE:
*1:(TCP/UDP)- {eq <source por t> | range <source port
start> <source port end>} *2 :(TCP/UDP)- {eq
<destination port> | range <destinati on port start>
<destination port end>} *3:(ICMP)- [{ <icmp type>
[<icmp code>] | <icmp message>}] *4:(TCP )-
[ack][fin][psh][rst][syn][urg] <cr>
71
<source ipv4> <source ipv6> <source mac>
5-19 ip access-list extended
(config-ext-nacl)# permit i icmp igmp ip ipinip
(config-ext-nacl)# permit ip a ⇒"any"
7 <interface id list>
monitor session <session no.> source interface <interface
id list> [{rx | tx | both}] destination interface <interface
id list>
<interface id list>
<interface id list>
(config)# monitor session 1 source interface gigabitethernet 0/1
<monitor frames> - {rx | tx | both}: Set monitor of receiving
frames / m onitor of transmitting frames / monitor of receiving and
transmitting frames destination - Specify a mirrored port (config)#
monitor session 1 source interface gigabitethernet 0/1,
gigabitethernet - gigabitethernet <interface no. list>: The
type of a p ort is specified in 10BASE-T/100BASE-TX/100BASE-FX/10
00BASE-T/1000BASE-X line Stack disable: "0/1","0/2-4" Stack enable:
"1/0/1","2/0/2-4" tengigabitethernet - tengigabitethernet
<interface no. list>: The type of a port is specified in
1000BASE-T/1000BASE-X/10GBASE- R line Stack disable:
"0/25-26","0/25" Stack enable: "1/0/25-26","2/0/25"
gigabitethernet/tengigabitethernet
5-21 2 <interface id list>
72
5-22 2 <interface id list>
<interface id list>
<cr>
<cr>
show
5-23 2 <interface id list> show
(config)# monitor session 1 source interface gigabitethernet 0/1,
gigabitetherne t 0/3 rx destination interface gigabitethernet 0/11,
!(config)# show : monitor session 1 source interface
gigabitethernet 0/1, gigabitethernet 0/3 rx d estination
gigabitethernet 0/11 ⇒
5-24 2 <interface id list> show
(config)# monitor session 1 source interface gigabitethernet 0/1,
gigabitetherne t 0/3 rx destination interface gigabitethernet 0/11
gigabitethernet 0/13 !(config)# show : monitor session 1 source
interface gigabitethernet 0/1, gigabitethernet 0/3 rx d estination
interface gigabitethernet 0/11, gigabitethernet 0/13 ⇒
8
(config)# no ip dhcp excluded-address 192.168.0.1 127.0.0.1⇒
<High address> - Last address of an excluded range⇒
<cr>
[Enter]
excluded-address 192.168.0.1"
[Tab]
# erase white-list address packet all channel-group-number port #
erase white-list a Do you wish to erase white-list (address and
packet)? (y/n): y #
"a" "address" "all" "a"
"all"
11
# configure …1 (config)#
# configure …1 (config)#
: : …2 :
!(config)# end …3 !# copy running-config startup-config …4 Do you
wish to copy from running-config to startup-config? (y/n) :y
#
1.
2.
defined .
copy
⇒
ftp
ftp VLAN IP
C:\TEMP backup.cnf
6-16
C:\TEMP>ftp 192.168.0.1 Connected to 192.168.0.1 220 AX2530S-24T
FTP server ready User (192.168.0.1:(none)): operator 331 Password
required Password: 230 User logged in ftp> asc 200 Type set to
A, ASCII mode ftp> ftp> put backup.cnf 200 Port set okay 150
Opening ASCII mode data connection 226 Transfer complete ftp:xxxxxx
bytes sent in xx.x Seconds (xx.xx Kbytes/sec) ftp> bye 221
Bye…see you later C:\TEMP>
copy RAMDISK
6-17 copy
> enable # copy ramdisk backup.cnf startup-config Do you wish to
copy from RAMDISK to startup-config? (y/n):y #
2
copy
PC
6-19
C:\TEMP>ftp 192.168.0.1 Connected to 192.168.0.1 220 AX2530S-24T
FTP server ready User (192.168.0.1:(none)): operator 331 Password
required Password: 230 User logged in ftp> asc 200 Type set to
A, ASCII mode ftp> ftp> get backup.cnf 200 Port set okay 150
Opening ASCII mode data connection 226 Transfer complete ftp:xxxxxx
bytes sent in xx.x Seconds (xx.xx Kbytes/sec) ftp> bye 221
Bye…see you later C:\TEMP>
6.5.2 MC
copy RAMDISK
> enable # copy mc backup.cnf ramdisk backup.cnf …1 # copy
ramdisk backup.cnf startup-config …2 Do you wish to copy from
RAMDISK to startup-config? (y/n): y #
1. MC RAMDISK
2. RAMDISK
copy RAMDISK MC
1.# show version
Date 20XX/10/20 17:38:02 UTC Model: AX2530S-24T S/W: OS-L2B Ver.
4.0 (Build:yy) H/W: AX-2530-24T-B [SSSSSSSSSSSSSSSSSSSSSS:R]
# A OS-L2B
2.# show version
Date 20XX/10/20 17:39:02 UTC Model: AX2530S-48T S/W: OS-L2B Ver.
4.0 (Build:yy) H/W: AX-2530-48T-B [SSSSSSSSSSSSSSSSSSSSSS:R]
# B OS-L2B 1 A
A
RAMDISK A
2. # set stack enable
Warning: the configuration will be lost on the next reload.
Do you wish to continue? (y/n): y
Warning: stacking is yet to be enabled.
A 1
4. # reload
A 20 10
(config-if)# switchport mode stack
A B 20
B 2
48T
(config-if)# switchport mode stack
5. (config)# switch 2 priority 10
B 2 A 10
MAC
MAC
MAC 26ae
MAC
MAC
B
RAMDISK B
2. # set stack enable
Warning: the configuration will be lost on the next reload.
Do you wish to continue? (y/n): y
B
Warning: stacking is yet to be enabled.
B 2
4. # reload
B
A
(config-if)# switchport mode stack
2. (config)# switch 2 priority 2
B 2 2
6 A B 2
1 A B
2
B
# show switch
show switch A "Master" B
"Stack member"
8.1.3
133
A C
save
1.# show version
Date 20XX/01/31 17:38:02 UTC Model: AX2530S-24T S/W: OS-L2B Ver.
4.0 (Build:yy) H/W: AX-2530-24T-B [SSSSSSSSSSSSSSSSSSSSSS:R]
# A OS-L2B
2.# show version
Date 20XX/01/31 17:39:02 UTC Model: AX2530S-48T S/W: OS-L2B Ver.
4.0 (Build:yy) H/W: AX-2530-48T-B [SSSSSSSSSSSSSSSSSSSSSS:R]
# B C OS-L2B 1 A
RAMDISK A
2. # set stack enable
Warning: the configuration will be lost on the next reload.
Do you wish to continue? (y/n): y
Warning: stacking is yet to be enabled.
A 1
4. # reload
A A
A B C
B 48T 2 2/0/49 2/0/50
C 24S4X 3 3/0/25 3/0/26
A 20 10
(config-if)# switchport mode stack
2. (config)# switch 1 priority 20
A B C 20
(config)# switch 3 provision 2530-24s4x
B C 2 3
48T24S4X
4. (config)# interface gigabitethernet 2/0/49
(config-if)# switchport mode stack
5. (config)# switch 2 priority 10
B 2 A 10
(config-if)# switchport mode stack
7. (config)# switch 3 priority 10
C 3 A 10
MAC
MAC
MAC 26ae
MAC
MAC
MODE
B C
Warning: the configuration will be lost on the next reload.
Do you wish to continue? (y/n): y
# reload
b MODE
1. ON
2. ST1 LED 10 MODE 3
5 A B C
B C
138
8. OS-L2A
show switch B C MAC
1.# show switch
Date 20XX/01/31 17:50:45 UTC Stack status : Enable Switch No : 1
MAC address : 0012.e200.ffa1 System MAC address :
0a12.e200.fff1
No Switch status Model Machine ID Priority OS Ver 1 Master 2530-48t
0012.e200.ffa1 20 4.0 - Restrict(Not initialized) - 0012.e200.ffb1
- - - Restrict(Not initialized) - 0012.e200.ffc1 - -
# Switch status Restrict(Not initialized) MAC
Remote setting is successful <0012.e200.ffb1>.
B MAC 0012.e200.ffb1
3. # set remote 0012.e200.ffb1 switch 2
Remote setting is successful <0012.e200.ffb1>.
B MAC 0012.e200.ffb1 2
4. # set remote 0012.e200.ffb1 stack enable
Remote setting is successful <0012.e200.ffb1>.
B MAC 0012.e200.ffb1enable
B B
139
Remote setting is successful <0012.e200.ffc1>.
C MAC 0012.e200.ffc1
7. # set remote 0012.e200.ffc1 switch 3
Remote setting is successful <0012.e200.ffc1>.
C MAC 0012.e200.ffc1 3
8. # set remote 0012.e200.ffc1 stack enable
Remote setting is successful <0012.e200.ffc1>.
C MAC 0012.e200.ffc1enable
C C
140
A C C
1.# show version
Date 20XX/01/17 03:52:23 UTC Switch number: 1 Model: AX2530S-24T
S/W: OS-L2A Ver. 4.0 (Build:yy) H/W: AX-2530-24T-B
[SSSSSSSSSSSSSSSSSSSSSS:R]
Switch number: 2
(2) A
# A OS-L2A
Date 20XX/01/17 03:53:12 UTC Model: AX2530S-24S4X S/W: OS-L2B Ver.
4.0 (Build:yy) H/W: AX-2530-24S4X-B
[SSSSSSSSSSSSSSSSSSSSSS:R]
# C OS-L2B 1
A
A
A 20 10
C 3
24S4X
(config-if)# switchport mode stack
3. (config)# switch 3 priority 10
C 3 10
142
C
RAMDISK C
2. # set stack enable
Warning: the configuration will be lost on the next reload.
Do you wish to continue? (y/n): y
C
Warning: stacking is yet to be enabled.
C 3
4. # reload
C
A
(config-if)# switchport mode stack
2. (config)# switch 3 priority 2
C 3 2
5 A C 3
A B C 3
# show switch
show switch A "Master" B C
"Stack member"
8.1.5
144
A D D
(2) A
save
# A OS-L2A
2.# show version
Date 20XX/01/31 18:33:12 UTC Model: AX2530S-24T S/W: OS-L2B Ver.
4.0 (Build:yy) H/W: AX-2530-24T-B [SSSSSSSSSSSSSSSSSSSSSS:R]
# D OS-L2B 1
A
A
A 20 5
D 4
24T
(config-if)# switchport mode stack
3. (config)# switch 4 priority 5
D 4 A 5
MODE
D
Warning: the configuration will be lost on the next reload.
Do you wish to continue? (y/n): y
# reload
b MODE
1. ON
2. ST1 LED 10 MODE 3
147
4 A D
D
show switch D MAC
1.# show switch
Date 20XX/01/31 18:50:15 UTC Stack status : Enable Switch No : 1
MAC address : 0012.e200.ffa1 System MAC address :
0a12.e200.fff1
No Switch status Model Machine ID Priority OS Ver 1 Master 2530-48t
0012.e200.ffa1 20 4.0 2 Stack member 2530-48t 0012.e200.ffb1 10 4.0
3 Stack member 2530-24s4x 0012.e200.ffc1 10 4.0 - Restrict(Not
initialized) - 0012.e200.ffd1 - -
# Switch status Restrict(Not initialized) MAC
Remote setting is successful <0012.e200.ffd1>.
D MAC 0012.e200.ffd1
3. # set remote 0012.e200.ffd1 switch 4
Remote setting is successful <0012.e200.ffd1>.
D MAC 0012.e200.ffd1 4
4. # set remote 0012.e200.ffd1 stack enable
Remote setting is successful <0012.e200.ffd1>.
D MAC 0012.e200.ffd1enable
D D
1
(config-if)# switchport mode stack
150
8.1.7
151
1
(config-if)# shutdown
(config-if)# exit
2
(config-if)# no switchport mode
2. (config)# save
NoSwitch status
8-7 show switch
> show switch
Date 20XX/01/31 19:38:56 UTC Stack status : Enable Switch No : 1
MAC address : 0012.e200.ffa1 System MAC address :
0a12.e200.fff1
>
9.1
9.2
9.3
adduser
4 7 OS-L2A
line vty
4. IPv4 IPv6 ip access-list standardipv6 access-listip
access-groupipv6 access-class
5. telnetftp transport input
ftp-server
6.
set exec-timeout
Vol.2 14
OS-L2A
> enable # adduser newuser User(empty password) add done. Please
setting password.
Changing local password for newuser. New password:******** … 1
Retype new password:******** … 2 # exit >
1.
2.
aaa authentication login
RADIUS 10.3.3
enable
ID
> enable # password enable-mode Changing local password for
admin. New password: Retype new password: #
aaa authentication enable RADIUS
10.3.3 enable
10.1.5
ftp
ftp-server ftp
line vty <End allocation>
16
164
ip access-list standardipv6 access-listip access-groupipv6
access-class
IP IPv4
IPv6 128
(config-std-nacl)# deny host 192.168.0.254
(config-std-nacl)# permit 192.168.0.0 0.0.0.255
REMOTE
(config-line)# ip access-group REMOTE in
(config-line)# exit
(config-ipv6-nacl)# exit
IPv6 REMOTE6
2. (config)# line vty 0 1
(config-line)# ipv6 access-class REMOTE6 in
(config-line)# exit
64
ip access-group ipv6 access-class IP
deny deny
10.1.8
telnet ftp
########################################## Warning!!! Warning!!!
Warning!!! This is our system. You should not login. Please close
connection. ##########################################
"##########################################\nWarning!!!
Warning!!!
Warning!!!\nThis is our system. You should not login.\nPlease
close
connection.\n##########################################\n"
3. (config)# show banner login plain-text
########################################## Warning!!! Warning!!!
Warning!!! This is our system. You should not login. Please close
connection.
166
telnet ftp
> telnet 10.10.10.10 Trying 10.10.10.10 ...
########################################## Warning!!! Warning!!!
Warning!!! This is our system. You should not login. Please close
connection. ########################################## login:
10-7 ftp
> ftp 10.10.10.10 Connecting...
167
10. RADIUS
10.2 RADIUS
10.2.1 RADIUS
RADIUS Remote Authentication Dial In User ServiceNASNetwork Access
Server
NAS RADIUS
NAS RADIUS
RADIUS
RADIUS
2 Vol.2
168
RADIUS
1 RADIUS
10-3 RADIUS
a RADIUS
DNS DNS
IP DNS
DNS
ipv6 host DNS IPv4 IPv6
IPv4
208
2 IPv6
12.2.3 DNS
1 DNS
ip domain lookup no ip domain lookup DNS
ip domain name DNS
ip domain reverse-lookup no ip domain reverse-lookup DNS
192.168.0.1
2 DNS
DNS
13.1
13.2
system logging format-add
system receive alarm logging no system receive alarm logging
CPU
system recovery no system recovery
64
reload
>
> show version
>
set logging console
> show system
Date 20XX/02/12 23:09:11 UTC System Name : - Contact : - Locate : -
MAC address : 0012.e2b2.37dd Switch Machine ID Boot Date Boot
reason Elapsed time 1 0012.e2a2.d273 20XX/02/09 21:54:56 Reload 3
days 01:14: 15 2 0012.e2b2.37dd 20XX/02/09 21:53:42 Reload 3 days
01:15: 29 Switch ST1 LED ST2 LED 1 Green Orange 2 Green Green
Brightness mode : normal MC configuration mode : disabled Power
redundancy-mode : check is not executed
Environment Fan PS EPU Current Temperature Running time( total)
Switch Speed EPU-Fan Accumulated Running time( critical) 1 active
active notconnect 60.82 W normal 1448 days and 0 hours normal -
6.81 kWh 0 days and 0 hours 2 active active notconnect 59.53 W
normal 1393 days and 12 hours normal - 6.84 kWh 0 days and 0
hours
File System < RAMDISK information > used 140,288 byte free
31,316,992 byte total 31,457,280 byte < RAMDISK files > There
is no file. ( RAMDISK ) < MC information > MC : not
connect
Device Resources IP Interface Entry : 3(max entry=128) IP Address
Entry : 3(max entry=128) IPv4 ARP Entry : 2(max entry=2560) IPv6
NDP Entry : 0(max entry=256) MAC-address Table Entry : 32415(max
entry=32768)
System Layer2 Table Mode : 1 Switch Limit queue length 1 64 2 64
Flow detection mode : layer2-2 Used resources for filter(Used/Max)
MAC IPv4 Port 1/0/1-52 : - 0/256 Port 2/0/1-52 : - 0/256 VLAN : -
0/256 Used resources for QoS(Used/Max) MAC IPv4
214
13.
>
> show system
Date 20XX/08/21 17:04:04 UTC System: AX2530S-24T Ver. 4.21
(Build:yy) Name : - Contact : - Locate : - Machine ID :
0012.e262.aaa1 Boot Date : 20XX/08/20 17:03:05 Boot reason :
Power-on Elapsed time : 1 days 00:00:59 LED ST1 LED : Green ST2 LED
: Light off Brightness mode : normal MC configuration mode :
disabled Zero-touch-provisioning status : enabled(no change)
Environment Power redundancy-mode : check is not executed Fan : -
Speed : - PS : active EPU : notconnect EPU Fan : - Current wattage
: 21.53 W Accumulated wattage : 0.02 kWh Temperature : normal
Accumulated running time total : 309 days and 6 hours critical : 15
days and 20 hours
File System < RAMDISK information > used 140,288 byte free
31,316,992 byte total 31,457,280 byte < RAMDISK files > There
is no file. ( RAMDISK ) < MC information > MC : not
connect
Device Resources IPv4 Routing Entry(static) : 5(max entry=128) IPv4
Routing Entry(connected) : 22(max entry=128) IP Interface Entry :
4(max entry=128) IP Address Entry : 4(max entry=128) IPv4 ARP Entry
: 11(max entry=2560) IPv6 NDP Entry : 7(max entry=256) MAC-address
Table Entry : 35(max entry=32768)
System Layer2 Table Mode : 1 Limit queue length : 64 Flow detection
mode : layer2-2 Used resources for filter(Used/Max) MAC IPv4 Port
0/1-28 : - 2/256 VLAN : - 2/256 Used resources for QoS(Used/Max)
MAC IPv4
215
13.
>
> show system capacities
Date 20XX/11/30 12:00:00 UTC < VLAN information > VLAN : 892
VLAN x Port : 9260
>
system fan mode
13-6
> show environment
Date 20XX/01/31 09:55:21 UTC Fan environment Switch Fan Speed Mode
1 active normal 2 (cool) 2 - - -
Power environment Switch PS EPU EPU-Fan 1 active notconnect - 2
active notconnect -
Temperature environment Switch Main Warning level 1 27 degrees C
normal 2 36 degrees C normal
Temperature-warning-level Switch Current(status/setting)
Average(status/setting) 1 27/37 degrees C -/- degrees C period 0
day(s)
2 36/37 degrees C -/- degrees C period 0 day(s)
>
> show environment
Date 20XX/07/27 18:12:36 UTC Fan environment Fan : active Speed :
normal Mode : 1 (silent) EPU Fan : -
Power environment PS : active EPU : notconnect
Temperature environment Main : 29 degrees C Warning level :
normal
Temperature-warning-level current status : 29/32 degrees C
Temperature-warning-level average status : 28/30 degrees C period
30 day(s)
>
> show environment temperature-logging
>
> show environment temperature-logging
Date 20XX/12/16 21:54:23 UTC Date 0:00 6:00 12:00 18:00 20XX/12/16
30.0 30.3 28.0 27.8 20XX/12/15 31.0 32.0 29.8 31.1
217
13.
>
SFP
show logging console
E5
System message mode : E5 >
show logging
1
/ : :
system logging format-add / / : :
show logging
show logging reference
show authentication logging
show logging
2 show authentication logging
IEEE802.1X show dot1x logging
Web show web-authentication logging
MAC show mac-authentication logging
syslog syslog TIMESTAMP
Jun 4 13:36:58 "hostname" [1]: WHT 06/04 13:36:58
Jun 4 13:36:58 "hostname" [1]: WHT 20XX/06/04 13:36:58
13.1.6
ID 9 1 17
MAC MAC DB
DHCP snooping
Wake on LAN 2 WOL DB
Wake on LAN
1
Web
"<!-- Original_URL -->"
Ver.3.5
"ramdisk" "page"
6 1
6 1
7
b
c
E9
227
snmp-server engineID local
copyerase startup-config
set stackset switch set remote switchset remote licenseset remote
stack
restorereload
ppupdateset licenseerase license
format flash
MAC commit mac-authenticationload mac-authentication
Wake on LAN commit wol-deviceload wol-devicecommit
wol-authenticationload wol-authentication
Web set access-redirect html-fileclear access-redirect
html-file
SNMP set snmp-server engineID local
228
14.1 MC
14.2 MC
14.3 MC
MC
MC
2. MC
update mc-configuration
update mc-configuration
MC
MC LEDACC LED
3MC
MC
MC
4
4
2
3 SMLOS-L2A
SML
MC
MC
4
4
update mc-configuration MC 14-1 MC
MC
2 MC
MC
MC LEDACC LED MC
MC MC MC
235
ppupdate 2 MC RAMDISK ftptftp
MC
237
2. AX-Network-ManagerDHCP
IP
AX-Network-ManagerTFTP
ppupdate
A-2 MACaa2 backupA2
A-2 B-2
15-3 A-2
15-4
AX-Network-Manager MAC
MAC aa2 MAC bb2
242
AX-Network-Manager backupA4 MAC aa2 bb2
LAN
15-5
15-6
AX-Network-Manager VLAN
MC
SMLOS-L2A
VLAN VLAN1
VLAN
244
245
VLAN
VLAN 4094
3. (config)# system zero-touch-provisioning
2
246
SFP SFP+/SFP 10G
2
×
LED
1 LED
LED
LED
LED ST1/ST2/ACC
LED PWR LEDPSIN1/PSIN208TC1
PoE Status LEDTEMPPWRPORT
08PLED
ST1
ST2
ACC
LINK
T/R
1 808P08TC1 1 1616P4X 1 2424T24T4X 1 4848T48T2X48P2X
system port-led LED LED
system port-led LED
enable economy disable
LED LED LED LED
ST1
OFF
SML 1
251
2
3
10BASE-T/100BASE-TX/1000BASE-T
LED
ACC
system port-led LED
enable economy disable
LED LED LED LED
252
2.
PWR LEDPSIN1/PSIN208TC1
PoE Status LEDTEMPPWRPORT08P
253
SFP SFP+/SFP 10G LED
2
10BASE-T/100BASE-TX/
1000BASE-T SFP SFP+/SFP 10G
ifAdminStatus Set
2
16.1.4
PWR LED
power-control port cool-standby
RESET
16-6 WOL
SFP 2 4 2
0/23 0/24 24T4X24S4X
10BASE-T/100BASE-TX/1000BASE-T 0/23 SFP 0/25 2
16-6 WOL
4. (config)# end
Unsaved changes would be lost when the machine goes to sleep!
Do you exit "configure" without save ? (y/n):
(config)# save
4
LED show system Brightness mode
13.1.3
> show power-control port
>
show system Fan13.1.3
16.3.5
> show power-control schedule XX0801
>
> show power
Date 20XX/08/04 09:49:05 UTC Elapsed time 0days 12:11:44 Current
wattage Accumulated wattage 73.36 W 0.99 kWh
>
17.1
17.2
17.3
285
tengigabitethernet 0/25
1 0/1 0/100/15 0/20 10G
0/25
0/10
2. (config-if)# shutdown
inactivate inactive active
disable active
no shutdown
save
MTU
4
0/10 MTU 8192 VLAN Tag
8206 VLAN Tag 8210
(config-if)# shutdown
2. (config-if)# no shutdown
10BASE-T 100BASE-TX
MTU 1500
2 MTU
4110 VLAN Tag 4114
10BASE-T 100BASE-TX
MTU 1500
287
0/10
(config-if)# exit
0/10
(config-if)# exit
Status up
show port
18-5
> show port
>
test interfaces
289
…10BASE-T100BASE-TX
( ) ×
2
3
18-8
desired
18-8
18-7
18-8
desired
18-8
18-8
on off
desired on on
on on
on off
desired on on
desired on on
on off
desired on on
off on on
off on
desired on on
on on
off off
desired on on
desired on on
off on
desired on on
desired on on on
off on
desired on on
on on
off on
desired on on
desired on on
off on
desired on on
off off off
off off
desired off off
on off
off off
desired on off
293
1
2
BI_Dx
off off
desired off off
desired on on
off off
desired on on
on on
off off
desired on on
desired on on
off off
desired on on
RJ45 MDI MDI-X
1 BI_DA TD TD BI_DB RD RD
2 BI_DA TD TD BI_DB RD RD
3 BI_DB RD RD BI_DA TD TD
4 BI_DC Unused Unused BI_DD Unused Unused
5 BI_DC Unused Unused BI_DD Unused Unused
6 BI_DB RD RD BI_DA TD TD
7 BI_DD Unused Unused BI_DC Unused Unused
8 BI_DD Unused Unused BI_DC Unused Unused
Tag 22.1.5 VLAN Tag Tag
100BASE-TX1000BASE-T
6
× MAC DA FCS
auto auto 10 100 1000
auto 10 100 auto 1000 or
auto 100 or
auto 10
1 On 1 10 100 1000 10 100 1000 10 100
2 2 10 100 10 100 10
3 3 10 10
on off
desired on on
on on
on off
desired on on
desired on on
on off
desired on on
off on on
off on
desired on on
305
off off
desired on on
desired on on
off on
desired on on
desired on on on
off on
desired on on
on on
off on
desired on on
desired on on
off on
desired on on
off off off
off off
desired off off
on off
off off
desired on off
desired off off
off off
desired off off
desired on on
off off
desired on on
on on
off off
desired on on
desired on on
off off
desired on on
inactivate power inline inact
offshutdown no shutdown off
on
denied
faulty shutdown off
activate power inline off
on
faulty
activate power inline off
on
inact
b "denied"
power inline
6
3
interface range
PoE 7 OS-L2A
10 PoE
PoE no power inline delay
18.15.1
PoE
PoE
(config-if)# power inline never
18.15.3
18-26 PoE
power inline delay PoE PoE
Please execute 'reload all' command after save,
because this command becomes effective after reboot.
3. (config-sw)# end
# copy running-config startup-config
Do you wish to copy from running-config to startup-config? (y/n):
y
Please execute the reload command after save,
because this command becomes effective after reboot.
2. (config)# end
# copy running-config startup-config
Do you wish to copy from running-config to startup-config? (y/n):
y
3. @# reload
(config-if)# power inline allocation limit 20000
0/1 20000mW20W
2. (config-if)# exit
18.15.5 PoE
PoE shutdown power inline never
PoE
PoE 300 60 PoE 0/1 0/10critical
PoE high
PoE 300 60
2. (config)# interface range gigabitethernet 0/1-10
0/1 0/10
0/1 0/10
4. (config-if-range)# exit
18.16.1
PoE
Status onPriority Class IEEE802.3af/IEEE802.3at
Power/Vol/Cur / /
PoE Status wait
show power inline
18-9 PoE 48P2X
> show power inline Please wait a little.
Date 20XX/08/22 20:15:07 UTC System Wattage: Switch Priority
Control Threshold(W) Total Allocate(W) Total Power(W) 1 enable
425.0 30.8 1.4 2 disable 425.0 0.0 0.0 …1. 3 enable 425.0 90.8 40.0
4 enable 425.0 397.8 186.0 Total 1700.0 519.4 227.4 Port Counts :
192 Port Status Priority Class Alloc(mW) Power(mW) Vol(V) Cur(mA)
Description 1/0/1 on low 0 15400 700 55.5 14 POE-SW1 1/0/2 off low
- 0 0 0.0 0 POE-SW1 1/0/3 off low - 0 0 0.0 0 POE-SW1 1/0/47 off
critical - 0 0 0.0 0 POE-SW1 1/0/48 on critical 0 15400 700 55.2 14
POE-SW1 2/0/1 off high - 0 0 0.0 0 POE-SW2 2/0/2 off high - 0 0 0.0
0 POE-SW2 : : : 3/0/1 off never - 0 0 0.0 0 POE-SW3 3/0/2 on low 4
30000 19300 54.7 353 POE-SW3 3/0/3 off low - 0 0 0.0 0 POE-SW3
3/0/4 off low - 0 0 0.0 0 POE-SW3 3/0/5 on low 0 15400 700 55.0 14
POE-SW3 : : :
activate power inline
inactivate power inline
18.
>
18-10 PoE
> show power inline Please wait a little.
>
source destination Down source
Up Down destination Up
destination source
destination 4 source source
source destination
Down source Up
source destination
source destination
link-relay source
show interfacesshow port destination "inactive"
> show channel-group
Date 20XX/12/06 18:20:48 UTC ChGr: 31 Mode: LACP CH Status : Down
Elapsed Time: - Max Active Port: 8 MAC address : - VLAN ID: 4093
Actor System : Priority: 128 MAC: 0012.e2a4.fe51 Key: 31 Partner
System : - Port Information 0/23 Down State: Detached 0/25 Down
State: Detached ChGr: 32 Mode: LACP CH Status : Up Elapsed Time:
00:15:16 Max Active Port: 8 Description : lab network MAC address :
0012.e254.ba14 VLAN ID: 4093 Periodic Timer : Long Actor System :
Priority: 128 MAC: 0012.e2a4.fe51 Key: 32 Partner System :
Priority: 128 MAC: 0012.e2a8.85a2 Key: 32 Port Information 0/26 Up
State: Distributing ChGr: 33 Mode: LACP CH Status : Down Elapsed
Time: - Max Active Port: 8 MAC address : - VLAN ID: 4093 Actor
System : Priority: 128 MAC: 0012.e2a4.fe51 Key: 33 Partner System :
- Port Information 0/22 Up State: Detached ChGr: 64 Mode: Static CH
Status : Up Elapsed Time: 00:15:21 Max Active Port: 8 MAC address :
0012.e254.ba12 VLAN ID: 4093 Port In