2
Key Features VL-MN1000 Room Monitor VL-VN1500 Door Station • High expandability Up to 20 Door Stations, 32 IP cameras and 5 Room Monitors can be connected. • PoE support The Door Station and Room Monitor support PoE (IEEE 802.3af compliant, class 2 device). A power supply unit is also available (VL-PS240 is sold separately). • Card reader The Door Station has an RFID reader that can be used to unlock the electric lock. Up to 10,000 cards can be recorded. • Electric lock release support* The electric lock can be easily and quickly released from the Room Monitors and the card reader on the Door Stations. *Optional relay box (VL-RLY1) is required. • Picture recording / FTP uploading** ** Consult Panasonic for FTP server setting. Up to 100 images can be recorded to the Room Monitor. Images can also be automatically uploaded to an FTP server when a visitor calls from a Door Station. • 7-inch touch screen The Room Monitor has a 7-inch wide LCD that clearly shows each visitor's face, and the touch screen provides an easy-to-use operation screen. • High-resolution camera, Night Vision with LED lights : The Door Station has a 1.3 M pixel camera that provides a clear image with a wide view of 113° (horizontal), 69° (vertical). You can check visitors even when it's dark outside. Door Station IP Camera Room Monitor PoE Switch Electric lock Electric lock Electric lock PoE Switch LAN cable Fibre Fibre #1 #2 #20 Up to 20 Up to 32 Up to 5 System Example IP Camera Integration Wiring distance: Door Station - Switching hub: Up to 100 m (UTP Cat5e or higher ) Room Monitor - Switching hub: Up to 100 m (UTP Cat5e or higher ) The Installation Guide is available at the following web site. https://panasonic.net/cns/pcc/support/intercom/mn1000/ * The system setup/configuration shall be made by the installer. R1 1 R3 R2 S2 1 S1 2 Switching hub (PoE Switch or Switch) Door station LAN cable LAN cable Electric lock Power supply 12 V AC/DC RELAY BOX DC-IN 24 V LAN R2R1 POWER SUPPLY UNIT* 24 V DC To AC power outlet DC-IN 24 V To AC power outlet * Power Supply Unit sold separately LAN 24 V DC POWER SUPPLY UNIT* Room monitor Operation Specification - Codec Format: H.264 (Fixed) - Image Resolution: 720p (1280x720 pixels) or less - Frame Rate: 20 fps or less Recommended Models - E-series - iPRO Maximum System Configuration Wiring Schematic Diagram IP Video Intercom System Room Monitor VL-MN1000 Door Station VL-VN1500

IP Video Intercom System Room Monitor VL-MN1000 Door Station · System Example IP Camera Integration Wiring distance: Door Station - Switching hub: ... IP Video Intercom System Room

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IP Video Intercom System Room Monitor VL-MN1000 Door Station · System Example IP Camera Integration Wiring distance: Door Station - Switching hub: ... IP Video Intercom System Room

Key Features

VL-MN1000Room Monitor

VL-VN1500Door Station

• High expandabilityUp to 20 Door Stations, 32 IP cameras and 5 Room Monitors can be connected.

• PoE supportThe Door Station and Room Monitor support PoE (IEEE 802.3af compliant, class 2 device). A power supply unit is also available (VL-PS240 is sold separately).

• Card readerThe Door Station has an RFID reader that can be used to unlock the electric lock. Up to 10,000 cards can be recorded.

• Electric lock release support*The electric lock can be easily and quickly released from the Room Monitors and the card reader on the Door Stations. *Optional relay box (VL-RLY1) is required.

• Picture recording / FTP uploading** ** Consult Panasonic for FTP server setting.

Up to 100 images can be recorded to the Room Monitor. Images can also be automatically uploaded to an FTP server when a visitor calls from a Door Station.

• 7-inch touch screenThe Room Monitor has a 7-inch wide LCD that clearly shows each visitor's face, and the touch screen provides an easy-to-use operation screen.

• High-resolution camera, Night Vision with LED lights :The Door Station has a 1.3 M pixel camera that provides a clear image with a wide view of 113° (horizontal), 69° (vertical). You can check visitors even when it's dark outside.

Door Station IP Camera

Room Monitor

PoE Switch

Electric lock

Electric lock

Electric lock

PoE Switch

LAN cable

Fibre

Fibre

#1

#2

#20

Up to

20Up to

32Up to

5

System Example

IP Camera Integration

Wiring distance:Door Station - Switching hub: Up to 100 m (UTP Cat5e or higher )Room Monitor - Switching hub: Up to 100 m (UTP Cat5e or higher )

The Installation Guide is available at the following web site.https://panasonic.net/cns/pcc/support/intercom/mn1000/* The system setup/configuration shall be made by the installer.

R11

R3 R2

S21

S1

2

Switching hub(PoE Switch or Switch)

Door station

LAN cable

LAN cable

Electriclock

Powersupply 12 V AC/DC

RELAY BOX

DC-IN24 V

LANR2R1

POWERSUPPLYUNIT*

24 V DC

To ACpower outlet

DC-IN24 V

To ACpower outlet

* Power Supply Unit sold separately

LAN

24 V DCPOWERSUPPLY UNIT*

Room monitor

■ Operation Specification - Codec Format: H.264 (Fixed) - Image Resolution: 720p (1280x720 pixels) or less - Frame Rate: 20 fps or less

■ Recommended Models - E-series - iPRO

Maximum System Configuration

Wiring Schematic Diagram

IP Video Intercom SystemRoom Monitor VL-MN1000

Door Station VL-VN1500

Page 2: IP Video Intercom System Room Monitor VL-MN1000 Door Station · System Example IP Camera Integration Wiring distance: Door Station - Switching hub: ... IP Video Intercom System Room

Model number VL-VN1500 (Door Station) VL-MN1000 (Room Monitor) VL-PS240 (Power Supply Unit) VL-RLY1 (Relay Box)Dimensions (Unit: mm)

Power source PoE (IEEE 802.3af compliant, Class 2 device) or Power supply unit (VL-PS240*1) 24 V DC, 0.6 A

PoE (IEEE 802.3af compliant, Class 2 device) or Power supply unit (VL-PS240*1) 24 V DC, 0.6 A

Input: 220-240 V AC, 0.2 A (50/60 Hz) Output: 24 V DC, 0.6 A Supplied by the main monitor

Power consumption PoE: Standby: 2.5 W, Operating: 5.1 WVL-PS240: Standby: 2.6 W, Operating: 6.3 W

PoE: Standby: 1.9 W, Operating: 6.3 WVL-PS240: Standby: 2.1 W, Operating: 6.2 W - -

Dimensions (H x W x D) (Excluding protruding sections)

141 x 100 x 28.5 mm 137.5 x 205 x 27.8 mm 116 x 100 x 54 mm 92 x 78 x 38 mm

Weight 250 g 550 g 230 g 130 g

Operating environment Ambient temperature: Approx. -10 °C to +55 °C Relative humidity (non-condensing): up to 90 %

Ambient temperature: Approx. 0 °C to +40 °C Relative humidity (non-condensing): up to 90 %

Ambient temperature: Approx. 0 °C to +50 °CRelative humidity (non-condensing): up to 90 % (indoor use only)

Ambient temperature: Approx. 0 °C to +40 °CRelative humidity (non-condensing): up to 90 %

Display - 7-inch wide colour display with touch screen (800x480 pixels) - -

Display language - English, Arabic, French, Italian, German, Spanish and Dutch - -

Talking method Hands-free Hands-free - -

Network interface 10BASE-T/100BASE-TX (Auto MDI/MDI-X) 10BASE-T/100BASE-TX (Auto MDI/MDI-X) - -

Network protocol TCP/IP, UDP TCP/IP, UDP - -

Wiring UTP (cat.5e or higher) UTP (cat.5e or higher) - -

Card reader (RFID) 13.56 MHz (ISO/IEC 14443 Type A (MIFARE)) - - -

Expanded interface E-lock x 1 *Relay box VL-RLY1 is required (sold separately)

Sensor input x 5 (including emergency / urgency button) - -

Viewing angle Horizontally: Approx. 113°, Vertically: Approx. 69° - - -

Image sensor 1.3 M pixel CMOS sensor - - -

Minimum illuminance required 1 lx (within approx. 50 cm from the camera lens) - - -

Lighting method White coloured LED lights - - -

Video / Audio format Video: H.264, Audio: G.711 Video: H.264, Audio: G.711 - -

Recording - Internal memory (video with audio can be saved) - -

IP rating / IK rating IP54*2 / - - - -

Installation method Surface mount (mounting base supplied) Surface mount (mounting bracket supplied) orFlush mount (mounting box VL-VN1790 sold separately) Wall mount or attach to DIN rail Wall mount or attach to DIN rail

External material PC+ABS resin PC+ABS resin Flame retardant PC+ABS resin Flame retardant ABS resin

*1 VL-PS240 is sold separately.*2 Water resistance is only assured if the Door Station is installed correctly according to the instructions in the Installation Guide, and appropriate water protection measures are taken.

36

Specifications

Installing the Room Monitor

Installing the Power Supply Unit Installing the relay Box

Installing the Door Station

Important– Safety Precaution: carefully read the operating instructions and installation manual before using this product.– Panasonic cannot be responsible for the performance of the network and/or other manufactures' products used on the network.

• The actual product may vary slightly from photograph.• Weights and dimensions are approximate.• Design and Specifications are subject to change without notice.• These products may be subject to export control regulations.

DISTRIBUTED BY :

MG-DHPL030EN 1807ITP/ZZZ-2

100205

100 78

141 137.5 116 92

28.527.8

54 38170

117

41

VL-VN1790(Mounting box)

(sold separately)

1450 mm500 mm

1140 mm

690 mm

1830 mm

56 mm

71.5 mm 69°1510 mm

113°

Remove screws

Remove screw

500 mm

Top view

Installation position

Installing by using the flush mount box (sold separately)

Side view

Front view

Top view E-Lock wire Door station wire

AC wiresFront view DC wires

Bottom viewTop view

45 mm

7 mm

25 mm

7 mm

9 mm

25 mm

7 mm

AC wire

DC wire

50 mm11 mm

58 mm

13 mm

72 mm107 mm

37 mm

DC -DC +

Insulation sleeve

DC wiresDC plug (included with VL-VN1500/VL-MN1000)