FINANCE, RISK AND SUPPLY CHAIN MANAGEMENT Page 1 November 1, 2019 INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR TENANT RENOVATIONS AT 814 RICHARDS STREET AMENDMENT No. 4 1. RE: SCHEDULE “A” (PART C – FORM OF TENDER), TABLE 1: TENDER PRICE Please replace current with table 1 below: TABLE 1: TENDER PRICE Item Description Amount (including PST) 1. General Conditions and Requirements $ 2. Site Work (Includes Abatement) $ 3. Wood, Plastics and Composites $ 4. Openings $ 5. Finishes $ 6. Specialties – Prefabricated partitions $ 7. Furnishings $ 8. Mechanical/Plumbing $ 9. Electrical, including data $ 10. Fire Suppression (Sprinkler new and relocation(s)) $ 11. Cash Allowance for Mural A $3,500.00 12. Cash Allowance for Mural B $3,500.00 13. Other (contingency allowances and any other work or costs not reflected in the items above but required to complete the Work covered by the Tender Documents) $ 14. Subtotal (including all PST) $ 15. GST (5%) $ 16. Tender Price (including all costs, taxes and fees) $ (including PST and GST)

INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

FINANCE, RISK AND SUPPLY CHAIN MANAGEMENT

Page 1

November 1, 2019

INVITATION TO TENDER (“ITT”) No. PS20191185

CONTRACTOR FOR TENANT RENOVATIONS AT 814 RICHARDS STREET

AMENDMENT No. 4

1. RE: SCHEDULE “A” (PART C – FORM OF TENDER), TABLE 1: TENDER PRICE

Please replace current with table 1 below:

TABLE 1: TENDER PRICE

Item Description Amount (including PST)

1. General Conditions and Requirements $

2. Site Work (Includes Abatement) $

3. Wood, Plastics and Composites $

4. Openings $

5. Finishes $

6. Specialties – Prefabricated partitions $

7. Furnishings $

8. Mechanical/Plumbing $

9. Electrical, including data $

10. Fire Suppression (Sprinkler new and relocation(s))

$

11. Cash Allowance for Mural A $3,500.00

12. Cash Allowance for Mural B $3,500.00

13. Other (contingency allowances and any other work or costs not reflected in the items above but required to complete the Work covered by the Tender Documents)

$

14. Subtotal (including all PST) $

15. GST (5%) $

16. Tender Price (including all costs, taxes and fees)

$ (including PST and GST)

Page 2: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

FINANCE, RISK AND SUPPLY CHAIN MANAGEMENT

Page 2

2. RE: SCHEDULE “A” (PART C – FORM OF TENDER), TABLE 2: ALTERNATE PRICES

Currently States:

Description

Price Change to Tender Price

Value to Add to Tender Price (inc. PST)

Value to Deduct from Tender Price (incl. PST)

Separate Price – refer to Mechanical Drawings (Note demolition and additional coils due to split AHU-4-CC1/HC1 & AHU-4-CC3/HC3 into 4 new sets of water coils)

$ $

Please Change to:

Description

Price Change to Tender Price

Value to Add to Tender Price (incl. PST)

Value to Deduct from Tender Price (incl. PST)

Separate Price – refer to New Mechanical Drawings for updated specifications for Fan Coil Units FC-1 and FC-3

$ $

3. RE: SCHEDULE “A” (PART C – FORM OF TENDER), TABLE 2: LIST OF UNIT PRICES FORADDITIONAL WORK

Please Add the Following to the Tender:

List of Unit Prices for Any Additional Work

These unit prices will be used for changing quantities from those indicated in the Tender Documents or Contract Documents upon written instruction from the City. The unit prices will be applied in accordance with PART 6 CHANGES IN THE WORK of the General Conditions of the Stipulated Price Contract (CCDC 2 – 2008), as modified by the Supplementary General Conditions (Schedule 1 to Part D – Form of Agreement). The prices should include (i) all labour, material and other costs, (ii) overhead and profit, (iii) PST, and (iv) all other taxes, duties, assessments, charges and fees, except for GST.

Item Description Unit Price (including PST)

1. Heating and Cooling coils (see note below)

$

This price includes:

Page 3: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

FINANCE, RISK AND SUPPLY CHAIN MANAGEMENT

Page 3

• Heating coils required in lieu of the fan coil units that were serving the adjacent tenantspace;

• Heating and cooling coils are to be installed complete with all associated accessories, referto installation detail. Heating and cooling coils are to be installed as per manufacturersrecommendations;

• Contractor to allow for the modification/extension of chilled water and heating watersupply and return lines. Allow for the insulating of new chilled and heating water lines;

• Contractor to allow for the modification of ductwork and for the provision of new ductworktransitions to suit the installation of coils;

• Heating and cooling coils are to be provided 3-way controls valves;

• All new control valves, actuators, sensors, thermostat, etc,. to match existing;

• Note that the location of the thermostat serving XFC-4-3 is revised, refer to attacheddrawings

4. RE: SPECIFICATIONS AND DRAWINGS

Please review the attached Mechanical Drawings M-0 to M-4, replacing the currentMechanical Drawings M-0 to M-4 in the tender package.

5. RE: SPECIFICATIONS AND DRAWINGS

Please see attached photographs of the Electrical Room in P1, Electrical Panels onLevel 4 and the relocated panel on Level 4.

6. RE: SPECIFICATIONS AND DRAWINGS

Please see sketches 1-8 to assist in the presentation of the tender.

7. RE: SPECIFICATIONS AND DRAWINGS

Please see Drawing/Spec on “New Power Plan Level 2”

8. RE: SPECIFICATIONS AND DRAWINGS

Please see updated Architectural Woodwork – Trim description for the SpecificationsSection 06 46 00, updated Lighting description for the Specifications Section 26 50 00(Note: L•4 Light Code corrected to match detailed description of fixtures. Supplierhas released pricing matching this new code - repricing not required).

Page 4: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

FINANCE, RISK AND SUPPLY CHAIN MANAGEMENT

Page 4

All other conditions and specifications remain unchanged.

This amendment must be completed, and attached to your Tender Form.

NAME OF VENDOR

________________________________________

SIGNATURE OF AUTHORIZED SIGNATORY

DATE

Page 5: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

UP

401

EXT'G CORRIDOR

402

STAIR # 1

403.1

EX SERVICE

EX WOMEN'S

403.3

EX MEN'S

403.2

405

STAIR # 2

404

OPEN

OFFICE

407

OPEN

OFFICE

406

OPEN

OFFICE

408

OPEN

OFFICE

409

OPEN

OFFICE

410

OPEN

OFFICE

411

OPEN

OFFICE

412

COPY/PRT.

413

OPEN

OFFICE

414

OPEN

OFFICE

415

OPEN

OFFICE

416

OPEN

OFFICE

417

BREAK

OUT/COLLAB.

418

CONFERENCE

RM. (10 PPL)

419

COFFEE

420

TRAINING

RM. (12 PPL)

421

BREAKOUT RM.

414

OFFICE

415

OFFICE

416

H/C

404

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

D

C

B

A

DRAWING LIST

This drawing is the property of the Designer andmay not be reproduced or used without theexpressed consent of the Designer. Allinformation shown on this drawings is for use onthis project only and shall not be usedotherwise. The Contractor is responsible forchecking and verifying all levels and dimensionsand shall report all discrepancies to theDesigner and obtain clarification prior tocommencing work. Do not scale the drawings.

flow consulting group inc.#1080 - 1075 west georgia streetvancouver, b.c. V6E 3C9v. 604 609 0500 f. 604 609 0588

C O N S U L T I N G

AutoCAD SHX Text
EBB-2
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
LINED SUPPLY
AutoCAD SHX Text
-
AutoCAD SHX Text
%%UGENERAL NOTES
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
0.5
AutoCAD SHX Text
STAMP/SEAL:
AutoCAD SHX Text
-
AutoCAD SHX Text
19/08/23
AutoCAD SHX Text
-
AutoCAD SHX Text
3.5
AutoCAD SHX Text
2.0
AutoCAD SHX Text
TAG-#
AutoCAD SHX Text
-
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
ALL
AutoCAD SHX Text
19/07/26
AutoCAD SHX Text
TAG
AutoCAD SHX Text
FC-1
AutoCAD SHX Text
SLAB OVER
AutoCAD SHX Text
16.14
AutoCAD SHX Text
COORDINATE WITH ARCHITECT
AutoCAD SHX Text
WORK PROJECT
AutoCAD SHX Text
Revisions
AutoCAD SHX Text
ISSUED FOR TENDER REV.1
AutoCAD SHX Text
ELECTRICAL (V/A/ )
AutoCAD SHX Text
TL
AutoCAD SHX Text
SHOP BASE BOARD HEATER
AutoCAD SHX Text
MAKE
AutoCAD SHX Text
CHROMALOX
AutoCAD SHX Text
4. Y-STRAINER WITH CLEAN OUT 5. VALVE BODY- 2-WAY 6. TOUR AND ANDERSON BALANCING VALVE C/W PRESSURE PORTS TOUR AND ANDERSON BALANCING VALVE C/W PRESSURE PORTS 7. RETURN ISOLATION VALVE - BALL VALVE WITH MEMORY STOP.
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
FD
AutoCAD SHX Text
1 HP
AutoCAD SHX Text
10.11
AutoCAD SHX Text
%%UFIRE PROTECTION LEGEND
AutoCAD SHX Text
16.14
AutoCAD SHX Text
ESP (IN)
AutoCAD SHX Text
SD-1
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
4 PIPE FAN FAN COIL UNIT
AutoCAD SHX Text
CFM
AutoCAD SHX Text
TOTAL COOLING (MBH)
AutoCAD SHX Text
1. C/W DRAIN PAN C/W DRAIN PAN 2. 3 SPEED FAN SWITCH (LOW, MED AND HIGH) 2. SUPPLY ISOLATION VALVE-BALL VALVE SUPPLY ISOLATION VALVE-BALL VALVE 3. VALVE ACTUATOR -MODULATING T-TYPE, THREE WIRE FLOATING
AutoCAD SHX Text
RTL
AutoCAD SHX Text
VIBRATION
AutoCAD SHX Text
Project:
AutoCAD SHX Text
-
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
1/2 HP
AutoCAD SHX Text
SCOPE OF WORK
AutoCAD SHX Text
43.2
AutoCAD SHX Text
W" x H"
AutoCAD SHX Text
EBB-X2
AutoCAD SHX Text
%%UELECTRIC HEATER SCHEDULE
AutoCAD SHX Text
BCHD024
AutoCAD SHX Text
UNION (TYP.)
AutoCAD SHX Text
.27
AutoCAD SHX Text
- T-BAR MOUNT
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
WALL MOUNTED
AutoCAD SHX Text
PLUMBING DIRECTION OF FLOW DOMESTIC COLD WATER DOMESTIC HOT WATER VENT LINE ABOVE GRADE SANITARY LINE BELOW GRADE SANITARY LINE PIPE CAPPED-OFF PIPE RISE (UP, TEE, DOWN) CHECK VALVE ISOLATION VALVE PRESSURE REDUCING VALVE SANITARY P-TRAP CONTINUATION OF PLUMBING PIPING ABOVE GRADE CLEANOUT
AutoCAD SHX Text
FAN
AutoCAD SHX Text
FAN COIL DETAIL (4 PIPE)
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
1.0
AutoCAD SHX Text
UNIT MOUNTED THERMOSTAT, MATCH EXISTING
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
-
AutoCAD SHX Text
HW SUPPLY & RETURN
AutoCAD SHX Text
ALL
AutoCAD SHX Text
BIN
AutoCAD SHX Text
M-0
AutoCAD SHX Text
MOTOR
AutoCAD SHX Text
UNIT MOUNTED THERMOSTAT
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
-
AutoCAD SHX Text
0.5
AutoCAD SHX Text
BL-2805
AutoCAD SHX Text
BCHD036
AutoCAD SHX Text
R
AutoCAD SHX Text
6
AutoCAD SHX Text
193
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
BIN
AutoCAD SHX Text
1,000
AutoCAD SHX Text
NEW WORK OR EXISTING RELOCATED
AutoCAD SHX Text
%%UAIR OUTLET SCHEDULE
AutoCAD SHX Text
50.8
AutoCAD SHX Text
SPEED CONTROL
AutoCAD SHX Text
10.11
AutoCAD SHX Text
SHIPPING WEIGHT (KG)
AutoCAD SHX Text
CHROMALOX
AutoCAD SHX Text
BL-3907
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
& SCHEDULE
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
FC-4
AutoCAD SHX Text
Sheet Info.
AutoCAD SHX Text
HANGER ROD
AutoCAD SHX Text
CONDENSATE DRAIN LINE
AutoCAD SHX Text
- T-BAR MOUNT
AutoCAD SHX Text
1,000
AutoCAD SHX Text
5
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
TOTAL HEATING (MBH)
AutoCAD SHX Text
ALL
AutoCAD SHX Text
A
AutoCAD SHX Text
BASE BOARD HEATER
AutoCAD SHX Text
208/1/60
AutoCAD SHX Text
19/09/18
AutoCAD SHX Text
SQUARE->ROUND
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
2,200
AutoCAD SHX Text
E.H. PRICE
AutoCAD SHX Text
Copyright C 2008 Flow Consulting Group Inc.
AutoCAD SHX Text
2019/07/26
AutoCAD SHX Text
0.5
AutoCAD SHX Text
SCD
AutoCAD SHX Text
BIN
AutoCAD SHX Text
ROUND->ROUND
AutoCAD SHX Text
-
AutoCAD SHX Text
'_pan
AutoCAD SHX Text
53.14
AutoCAD SHX Text
RESTRAINTS TO
AutoCAD SHX Text
RTL
AutoCAD SHX Text
208/1/60
AutoCAD SHX Text
TRANE
AutoCAD SHX Text
ISOLATOR TYP.
AutoCAD SHX Text
COIL CONTROL VALVE (TYP.)
AutoCAD SHX Text
SQUARE->SQUARE
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
%%U KEY PLAN
AutoCAD SHX Text
TOUR AND ANDERSON BALANCING VALVES C/W PRESSURE PORTS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DIA.
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
FLEXIBLE CONNECTIONS
AutoCAD SHX Text
1 HP
AutoCAD SHX Text
TRANE
AutoCAD SHX Text
ECCENTRIC REDUCERS (AS REQURED)
AutoCAD SHX Text
ATTACH TO
AutoCAD SHX Text
MAKE
AutoCAD SHX Text
CHW RETURN
AutoCAD SHX Text
NOTE: SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR REQUIREMENTS AROUND RELOCATED/NEW SPRINKLER HEADS. SPRINKLER ENGINEER SHALL BE HIRED BY SPRINKLER CONTRACTOR AS REQUIRED TO MEET CITY OF VANCOUVER BYLAWS.
AutoCAD SHX Text
1 HP
AutoCAD SHX Text
19/08/16
AutoCAD SHX Text
5.08
AutoCAD SHX Text
2
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
230
AutoCAD SHX Text
NOTES :
AutoCAD SHX Text
1,200
AutoCAD SHX Text
208/1/60
AutoCAD SHX Text
TRANE
AutoCAD SHX Text
0.75
AutoCAD SHX Text
-
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
M-0 SITE PLAN, MECHANICAL LEGEND & SCHEDULES SITE PLAN, MECHANICAL LEGEND & SCHEDULES M-1 HVAC DEMO/NEW WORK HVAC DEMO/NEW WORK M-2 PLUMBING DEMO/NEW WORK PLUMBING DEMO/NEW WORK M-3 MECHANICAL SPECIFICATIONSMECHANICAL SPECIFICATIONS
AutoCAD SHX Text
AIR VENT (TYP.)
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
FLOW (GPM)GPM))
AutoCAD SHX Text
500
AutoCAD SHX Text
Title
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
%%UHVAC LEGEND
AutoCAD SHX Text
A.P.
AutoCAD SHX Text
19-115
AutoCAD SHX Text
BIN
AutoCAD SHX Text
FLUID PD (FtWC)FtWC))
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
A.P.
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
MAKE
AutoCAD SHX Text
TAG
AutoCAD SHX Text
MAKE
AutoCAD SHX Text
FD
AutoCAD SHX Text
%%UFAN COIL UNIT SCHEDULE (SEPARATE PRICE)
AutoCAD SHX Text
ISOLATING VALVE
AutoCAD SHX Text
1
AutoCAD SHX Text
4 PIPE FAN FAN COIL UNIT
AutoCAD SHX Text
5.98
AutoCAD SHX Text
T
AutoCAD SHX Text
-
AutoCAD SHX Text
EBB-1
AutoCAD SHX Text
COORDINATE WITH ARCHITECT
AutoCAD SHX Text
208/1/60
AutoCAD SHX Text
TAG
AutoCAD SHX Text
2.54
AutoCAD SHX Text
53.14
AutoCAD SHX Text
19/09/30
AutoCAD SHX Text
208/1/60
AutoCAD SHX Text
2.0
AutoCAD SHX Text
ACOUSTICALLY
AutoCAD SHX Text
TAG
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
RETURN AIR
AutoCAD SHX Text
FLOW (GPM)GPM))
AutoCAD SHX Text
CHW SUPPLY
AutoCAD SHX Text
E.H. PRICE
AutoCAD SHX Text
BIN
AutoCAD SHX Text
66.0
AutoCAD SHX Text
SITE PLAN,
AutoCAD SHX Text
4 PIPE FAN FAN COIL UNIT
AutoCAD SHX Text
8. 7-DAY PROGRAMMABLE THERMOSTAT
AutoCAD SHX Text
FC-3
AutoCAD SHX Text
M-0
AutoCAD SHX Text
DRAWING NAME
AutoCAD SHX Text
LEGEND,
AutoCAD SHX Text
TOUR AND ANDERSON BALANCING VALVE C/W PRESSURE PORTS
AutoCAD SHX Text
208/1/60
AutoCAD SHX Text
80.31
AutoCAD SHX Text
BCHD024
AutoCAD SHX Text
ISSUED FOR BP/TENDER
AutoCAD SHX Text
500
AutoCAD SHX Text
3
AutoCAD SHX Text
0.5
AutoCAD SHX Text
PROGRESS SET
AutoCAD SHX Text
FIRE PROTECTION EXISTING FIRE EXTINGUISHER NEW FIRE EXTINGUISHER
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
BIN
AutoCAD SHX Text
EBB-X1
AutoCAD SHX Text
ALL
AutoCAD SHX Text
BIN
AutoCAD SHX Text
1. FIRE SUPPRESSION CONTRACTOR: FIRE SUPPRESSION CONTRACTOR: 1.1. H20 - FRANKIE CARUK, [email protected] H20 - FRANKIE CARUK, [email protected] 2. HVAC CONTRACTOR: HVAC CONTRACTOR: 2.1. HONEYWELL - RYAN TUNG, [email protected] HONEYWELL - RYAN TUNG, [email protected]
AutoCAD SHX Text
UNIT MOUNTED THERMOSTAT
AutoCAD SHX Text
REVIEW SET
AutoCAD SHX Text
V
AutoCAD SHX Text
10.28
AutoCAD SHX Text
814 RICHARDS STREET
AutoCAD SHX Text
AIR PLENUM
AutoCAD SHX Text
ISSUED FOR BP REVIEW
AutoCAD SHX Text
%%UEXISTING ELECTRIC HEATER SCHEDULE
AutoCAD SHX Text
FLUID PD (FtWC)FtWC))
AutoCAD SHX Text
AIR FLOW (CFM)
AutoCAD SHX Text
1
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
BACKGROUND
AutoCAD SHX Text
CONTRACTOR IS TO PROVIDE, AT END OF JOB, THE LISTED DOCUMENTS PRIOR TO SIGN OFF BY THE ENGINEER. 1. ALL NECESSARY INTERIM AND FINAL INSPECTION CERTIFICATES FROM THE ALL NECESSARY INTERIM AND FINAL INSPECTION CERTIFICATES FROM THE CITY OF VANCOUVER. 2. SCHEDULE CB FOR SPRINKLERS & SEISMIC RELATED WORK. SCHEDULE CB FOR SPRINKLERS & SEISMIC RELATED WORK. 3. PENETRATION FIRE STOPPING INSTALLATION CERTIFICATES. PENETRATION FIRE STOPPING INSTALLATION CERTIFICATES. 4. TESTING AND AIR BALANCING (AIR) REPORT IN PDF FORMAT. ACCEPTABLE TESTING AND AIR BALANCING (AIR) REPORT IN PDF FORMAT. ACCEPTABLE AGENCIES: KD ENGINEERING, WESTERN MECHANICAL. 4.1. PROVIDE MEASURED AIR FLOW REPORT PROVIDE MEASURED AIR FLOW REPORT 4.2. PROVIDE THERMOSTAT CALIBRATION REPORT PROVIDE THERMOSTAT CALIBRATION REPORT 4.3. PROVIDE PROGRAMMABLE CONTROLS SETTING SUMMARY PROVIDE PROGRAMMABLE CONTROLS SETTING SUMMARY 5. AS-BUILT DRAWINGS BY CONTRACTOR, PROVIDE A CLEAN COPY OF CAD & AS-BUILT DRAWINGS BY CONTRACTOR, PROVIDE A CLEAN COPY OF CAD & PDF 5.1. PROVIDE A SET FOR EACH DISCIPLINE (HVAC, PLUMBING, CONTROLS, PROVIDE A SET FOR EACH DISCIPLINE (HVAC, PLUMBING, CONTROLS, FIRE PROTECTION) 5.2. INCLUDE STAMP INDICATING WHICH CONTRACTOR PREPARED THE INCLUDE STAMP INDICATING WHICH CONTRACTOR PREPARED THE MARKUPS WHICH THE AS-BUILT IS BASED. 5.3. FOR CONTROLS, PROVIDE SCREEN SHOT OF UPDATED GRAPHICS FOR CONTROLS, PROVIDE SCREEN SHOT OF UPDATED GRAPHICS 6. COMPLETE O&M MANUAL, IN BINDER FORMAT. INCLUDE NEW EQUIPMENT COMPLETE O&M MANUAL, IN BINDER FORMAT. INCLUDE NEW EQUIPMENT INFORMATION, PRINT OF CAD AS-BUILT COPIES, LETTERS OF ASSURANCE, WARRANTIES, UPDATED DDC GRAPHICS, ETC. 7. ANY ADDITIONAL DOCUMENTS REQUIRED AND LISTED IN FIELD REPORTS. ANY ADDITIONAL DOCUMENTS REQUIRED AND LISTED IN FIELD REPORTS. 8. 1 WEEK INDICATION IS TO BE PROVIDED TO ENGINEER THAT MECHANICAL 1 WEEK INDICATION IS TO BE PROVIDED TO ENGINEER THAT MECHANICAL SYSTEM IS COMPLETE AND COMMISSIONED SO THAT ENGINEER MAY PROVIDE CLIENT ORIENTATION OF SYSTEM OPERATION.
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
O/A (CFM)
AutoCAD SHX Text
0.75
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
324
AutoCAD SHX Text
SLAB OVER (TYP.)
AutoCAD SHX Text
ISSUED FOR TENDER
AutoCAD SHX Text
BIN
AutoCAD SHX Text
TAG-#
AutoCAD SHX Text
RG-1
AutoCAD SHX Text
500
AutoCAD SHX Text
ELEMENT (KW)
AutoCAD SHX Text
24"X24"
AutoCAD SHX Text
A.P.
AutoCAD SHX Text
BIN
AutoCAD SHX Text
SHIPPING WEIGHT (KG)
AutoCAD SHX Text
EGG CRATE RETURN GRILLE
AutoCAD SHX Text
SQUARE CONE SUPPLY DIFFUSER
AutoCAD SHX Text
36
AutoCAD SHX Text
UNIT MOUNTED THERMOSTAT, MATCH EXISTING
AutoCAD SHX Text
VANCOUVER, BC
AutoCAD SHX Text
M
AutoCAD SHX Text
T
AutoCAD SHX Text
PLUMBING FIXTURES
AutoCAD SHX Text
4 PIPE FAN FAN COIL UNIT
AutoCAD SHX Text
0.5
AutoCAD SHX Text
4.26
AutoCAD SHX Text
%%U (2-WAY CONTROL VALVE)
AutoCAD SHX Text
BASE BOARD HEATER
AutoCAD SHX Text
PROVIDE SEISMIC
AutoCAD SHX Text
BCHD072
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
%%UPLUMBING LEGEND
AutoCAD SHX Text
%%ULANDLORD REQUIRED CONTRACTORS
AutoCAD SHX Text
BIN
AutoCAD SHX Text
230
AutoCAD SHX Text
AIR DISTRIBUTION RECTANGULAR/ROUND DUCTWORK AIRFLOW DIRECTION BRANCH TAKEOFF SUPPLY DUCT (UP, DOWN) RETURN OR TRANSFER DUCT (UP, DOWN) EXHAUST DUCT (UP, DOWN) ROUND DUCT (UP, DOWN) SUPPLY DIFFUSER, NEW/EXISTING/DEMO RETURN GRILLE, NEW/EXISTING/DEMO EXHAUST GRILLE, NEW/EXISTING/DEMO LINEAR DIFFUSER, NEW/EXISTING/DEMO FAN COIL UNIT (FCU) DUCT LINER/SINGLE LINE LINER ACCESS PANEL TOP,BOTTOM,SIDE TRANSFER DUCT C/W ACOUSTIC LINER BALANCING DAMPER FIRE DAMPER HORIZONTAL/VERTICAL DUCT CONTINUATION OF DUCTWORK DOUBLE/SINGLE LINE CONTROLS CONTROL WIRING THERMOSTAT COUNT DOWN TIMER REVERSE ACTING THERMOSTAT VARIABLE SPEED SWITCH AIR TERMINAL TAG BALANCE AIR QUANTITY A = CFM MECHANICAL EQUIPMENT TAG
AutoCAD SHX Text
%%UPROJECT CLOSE-OUT DOCUMENTS BY CONTRACTOR
AutoCAD SHX Text
FC-5
AutoCAD SHX Text
ALL PLUMBING FIXTURES ARE TO BE CSA APPROVED. KS-1: KITCHEN SINK: KITCHEN SINK: SINGLE BOWL UNDERCOUNTER SINK. 304 SS, SATIN FINISH RIM, FULLY UNDERGOATED. 533x406x127. POLISHED CHROME FINISH FAUCET C/W LEVER HANDLE, PULLOUT SPRAY, AERATOR OUTLET, BRAIDED FLEXIBLE HOSES. MAKE & MODEL: FRANKE UCS6105P-1, 4285.300.002 PORTSMOUTH SINGLE HANDLE FAUCET, 605XTMV1070.007 POINT OF USE THERMOSTATIC WATER MIXING VALVE.
AutoCAD SHX Text
TRANE
AutoCAD SHX Text
0.5
AutoCAD SHX Text
4th FLOOR FLEX
AutoCAD SHX Text
THERMOSTAT & FAN
AutoCAD SHX Text
80/TB/
AutoCAD SHX Text
43.2
AutoCAD SHX Text
DATE
AutoCAD SHX Text
1.0
AutoCAD SHX Text
DRAIN VALVE (TYP.)
AutoCAD SHX Text
BRAIDED SS.
AutoCAD SHX Text
%%UPLOT GRAYSCALE LEGEND
AutoCAD SHX Text
NO.
AutoCAD SHX Text
19/10/30
AutoCAD SHX Text
1. LOCATION OF EXISTING EQUIPMENT SHOWN ON THIS DRAWING IS FOR LOCATION OF EXISTING EQUIPMENT SHOWN ON THIS DRAWING IS FOR INFORMATION ONLY. CONTRACTOR SHOULD REVIEW AND CHECK THE EXACT LOCATION, SIZE, ELEVATION AND INVERT OF ALL EXISTING EQUIPMENT, THERMOSTATS, DUCTWORK AND PIPING ON SITE PRIOR TO COMMENCING WITH WORK. 2. REMOVE ALL DUCTWORK, GRILLES AND DIFFUSERS AS SHOWN ON REMOVE ALL DUCTWORK, GRILLES AND DIFFUSERS AS SHOWN ON DRAWING. 3. TURN OVER TO LANDLORD, ALL UNUSED EQUIPMENT (I.E THERMOSTATS, TURN OVER TO LANDLORD, ALL UNUSED EQUIPMENT (I.E THERMOSTATS, DIFFUSER, ETC.) 4. CONTRACTOR TO COORDINATE EXACT DUCTWORK ROUTING WITH CONTRACTOR TO COORDINATE EXACT DUCTWORK ROUTING WITH MECHANICAL DUCTING AND PIPING IN CEILING SPACE. MODIFY TO SUIT SITE CONDITIONS WITHOUT EXTRA COST TO THE OWNER. PROVIDE ADEQUATE OFFSETS, AND TRANSITIONS ON NEW DUCTWORK AS REQUIRED. 5. PROVIDE OVERSIZED OPENINGS IN NEW FULL-HEIGHT WALLS FOR PROVIDE OVERSIZED OPENINGS IN NEW FULL-HEIGHT WALLS FOR EXISTING DUCTWORK, PIPES AND CONDUIT TO PASS THROUGH WITH 13mm THICK NEOPRENE SLEEVE OR FIBERGLASS WRAP FOR SOUND ATTENUATION. GAPS SHOULD BE SEALED WITH NON-HARDENING FLEXIBLE (E.G. SILICONE) CAULK. 6. CONTRACTOR TO PROVIDE A MAXIMUM OF 36" OF FLEXIBLE DUCT CONTRACTOR TO PROVIDE A MAXIMUM OF 36" OF FLEXIBLE DUCT CONNECTION TO A DIFFUSER. 7. VERIFY CEILING TILE SIZE TO ENSURE PROPER FIT OF GRILLES AND VERIFY CEILING TILE SIZE TO ENSURE PROPER FIT OF GRILLES AND DIFFUSERS. 8. PROVIDE BALANCING DAMPER FOR EACH TAKE OFF FROM NEW PROVIDE BALANCING DAMPER FOR EACH TAKE OFF FROM NEW EQUIPMENT AND BALANCE AIR FLOW TO DESIGN RATE SHOWN ON DRAWING. CAP OFF ALL BRANCHES WHICH HAVE NOT BEEN USED. 9. EXISTING FCUS AND HEATING/COOLING COILS TO BE TESTED FOR EXISTING FCUS AND HEATING/COOLING COILS TO BE TESTED FOR FCUS AND HEATING/COOLING COILS TO BE TESTED FOR TO BE TESTED FOR PROPER CONTROLLED OPERATION AND CONDITION. DEFICIENCIES TO BE REPORTED IN WRITING TO LANDLORD. 10. CONTRACTOR TO PROVIDE SEISMIC RESTRAINT AND SEISMIC ENGINEER CONTRACTOR TO PROVIDE SEISMIC RESTRAINT AND SEISMIC ENGINEER AND SEISMIC ENGINEER LETTER OF ASSURANCE FOR ALL NEW AND RELOCATED MECHANICAL FOR ALL NEW AND RELOCATED MECHANICAL EQUIPMENT (DIFFUSERS, FANS, ETC.). 11. CONTRACTOR TO ENSURE ROOM THERMOSTAT LOCATIONS AS SHOWN ON CONTRACTOR TO ENSURE ROOM THERMOSTAT LOCATIONS AS SHOWN ON DRAWINGS ARE COORDINATED WITH THE HVAC EQUIPMENT SERVING ALL PARTICULAR SPACES. THERMOSTATS TO BE CHECKED FOR PROPER OPERATION AND CALIBRATED. DEFECTIVE STATE TO BE REPORTED TO BUILDING MAINTENANCE FOR REPAIR/REPLACEMENT. 12. COORDINATE THERMOSTAT LOCATIONS WITH INTERIOR DESIGNER TO AVOID COORDINATE THERMOSTAT LOCATIONS WITH INTERIOR DESIGNER TO AVOID INTERIOR DESIGNER TO AVOID TO AVOID CONFLICT WITH FURNITURE LAYOUT, WALL DETAILS. DO NOT LOCATE NEAR HEAT EMITTING DEVICES, OR IN ACCESS OF DIRECT SUNLIGHT. 13. VERIFY ACTUAL LOCATION AND SIZE OF EXISTING BUILDING SANITARY VERIFY ACTUAL LOCATION AND SIZE OF EXISTING BUILDING SANITARY DRAIN CONNECTION PRIOR TO LAYING OR INSTALLING ANY NEW RELATED PIPING. 14. ALLOW FOR X-RAY AND CORE OF ALL SANITARY LINE PENETRATIONS OF ALLOW FOR X-RAY AND CORE OF ALL SANITARY LINE PENETRATIONS OF STRUCTURAL WALLS AND FLOORS. 15. PATCH AND MAKE GOOD DAMAGED FLOOR, CEILING OR WALL FOR NEW PATCH AND MAKE GOOD DAMAGED FLOOR, CEILING OR WALL FOR NEW MECHANICAL WORK. 16. NEW PLUMBING FIXTURES TO BE CONNECTED TO EXISTING SANITARY AND NEW PLUMBING FIXTURES TO BE CONNECTED TO EXISTING SANITARY AND VENT PIPING. 17. CONTRACTOR TO LABEL ALL PLUMBING LINES IN CEILING SPACE AT CONTRACTOR TO LABEL ALL PLUMBING LINES IN CEILING SPACE AT EVERY 20FT AND AFTER EVERY CHANGE IN DIRECTION. INCLUDE INSTALLATION DATE FOR ALL NEW PIPING LABELING (MONTH/YEAR). REFER TO PIPE IDENTIFICATION DETAIL. 18. PROVIDE SHEET METAL CAPS FOR ALL UN-USED BRANCH CONNECTIONS. PROVIDE SHEET METAL CAPS FOR ALL UN-USED BRANCH CONNECTIONS. CAULK WITH HIGH PRESSURE MASTIC. 19. PRIOR TO DEMOLITION OR CONSTRUCTION, PROVIDE TEMPORARY FILTER PRIOR TO DEMOLITION OR CONSTRUCTION, PROVIDE TEMPORARY FILTER MATERIAL AT MAIN DUCTWORK TO PREVENT CONSTRUCTION DUST FROM ENTERING THE HVAC SYSTEM. REMOVE AT END OF JOB. 20. BRANCH DUCT SIZE TO MATCH THAT OF DIFFUSER NECK SIZE. BRANCH DUCT SIZE TO MATCH THAT OF DIFFUSER NECK SIZE. 21. PROVIDE 1" THICK INTERNAL ACOUSTIC DUCT INSULATION ON PROVIDE 1" THICK INTERNAL ACOUSTIC DUCT INSULATION ON 1" THICK INTERNAL ACOUSTIC DUCT INSULATION ON THICK INTERNAL ACOUSTIC DUCT INSULATION ON INTAKE/DISCHARGE DUCTWORK FOR TRANSFER FANS. 22. COORDINATE WITH ALL EXISTING MECHANICAL INSTALLATIONS INSIDE CRU. COORDINATE WITH ALL EXISTING MECHANICAL INSTALLATIONS INSIDE CRU. 23. TRANSFER DUCTS TO BE INSTALLED IN ALL INDIVIDUAL ROOMS TRANSFER DUCTS TO BE INSTALLED IN ALL INDIVIDUAL ROOMS INCORPORATING WALLS THAT ARE CONTINUED TO THE SLAB THROUGH THE CEILING SPACE. EVEN IF EXHAUST SYSTEMS ARE PROVIDED. REFER TO TRANSFER DUCT DETAIL. 24. ALL CONTROLS WORK TO BE DONE BY HONEYWELL. ALL CONTROLS WORK TO BE DONE BY HONEYWELL. 25. MECHANICAL CONTRACTOR IS TO SEND A COMPLETE SET OF DRAWINGS MECHANICAL CONTRACTOR IS TO SEND A COMPLETE SET OF DRAWINGS TO THEIR SUB-TRADES AND ANY SUPPLIERS AT TIME OF TENDER. NO CHANGES WILL BE CONSIDERED BY ANY SUB-TRADE OR SUPPLIER CLAIMING THAT THEY WERE NOT AWARE OF THE COMPLETE PROJECT SCOPE.
AutoCAD SHX Text
T
AutoCAD SHX Text
OF FOUR
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
A
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
M1
AutoCAD SHX Text
COLOUR
AutoCAD SHX Text
500
AutoCAD SHX Text
SHOP BASE BOARD HEATER
AutoCAD SHX Text
WEIGHT (LBS)
AutoCAD SHX Text
DN
AutoCAD SHX Text
QTY@
AutoCAD SHX Text
ELECTRICAL (V/A/ )
AutoCAD SHX Text
ELEMENT (KW)
AutoCAD SHX Text
4
AutoCAD SHX Text
4.01
Page 6: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

MEETING ROOM

404

BREAK-OUT RM

403

OFFICE/BREAK-OUT RM

402

OPEN WORK AREA 'A'

414

OPEN WORK AREA 'C'

413

OPEN WORK AREA 'D'

410

KITCHEN

409

WELLNESS ROOM

408

OFFICE/BREAK-OUT RM

406

MECH RM

405

PHOTOCOPY

407

OPEN WORK AREA 'C'

413

ENTRY/LOCKERS

401

OPEN LOUNGE

415

OPEN LOUNGE 'C'

411

NORTHNORTH

NEW CONSTRUCTION DRAWING NOTES NEW CONSTRUCTION KEYED NOTES

SEPARATE PRICEALTERNATE PRICE

UP

17

'-6

"2

3'-4

"1

6'-1

1"

17

'-2

"2

4'-0

"

24'-9" 24'-10" 24'-10" 24'-10" 16'-10"

ELEVATOR

COLLAB.

COLLAB.

COLLAB.

401

EXT'G CORRIDOR

402

STAIR # 1

403.1

EX SERVICE

EX WOMEN'S

403.3

EX MEN'S

403.2

405

STAIR # 2

404

OPEN

OFFICE

407

OPEN

OFFICE

406

OPEN

OFFICE

408

OPEN

OFFICE

409

OPEN

OFFICE

410

OPEN

OFFICE

411

OPEN

OFFICE

412

COPY/PRT.

413

OPEN

OFFICE

414

OPEN

OFFICE

415

OPEN

OFFICE

416

OPEN

OFFICE

417

BREAK

OUT/COLLAB.

418

CONFERENCE

RM. (10 PPL)

419

COFFEE

420

TRAINING

RM. (12 PPL)

421

BREAKOUT RM.

414

OFFICE

415

OFFICE

416

H/C

404

1 2 3 4 5 6

1 2 3 4 5 6

D

C

B

A

NORTHNORTH

DEMOLITION DRAWING NOTES DEMOLITION KEYED NOTES

SEPARATE PRICE

This drawing is the property of the Designer andmay not be reproduced or used without theexpressed consent of the Designer. Allinformation shown on this drawings is for use onthis project only and shall not be usedotherwise. The Contractor is responsible forchecking and verifying all levels and dimensionsand shall report all discrepancies to theDesigner and obtain clarification prior tocommencing work. Do not scale the drawings.

flow consulting group inc.#1080 - 1075 west georgia streetvancouver, b.c. V6E 3C9v. 604 609 0500 f. 604 609 0588

C O N S U L T I N G

AutoCAD SHX Text
RG-1
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
19/10/30
AutoCAD SHX Text
WORK PROJECT
AutoCAD SHX Text
250
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
M-1
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
500W
AutoCAD SHX Text
25"x10"
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
DEMOLISH EXISTING WINDOW MOUNTED FAN AND CONTROLS
AutoCAD SHX Text
140
AutoCAD SHX Text
EXISTING FRESH AIR SUPPLY TO MAIN AIR HANDLING UNIT
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
3
AutoCAD SHX Text
5
AutoCAD SHX Text
25"x10"
AutoCAD SHX Text
30"x10"
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
%%U PARTIAL 4TH FLOOR PLAN - HVAC NEW WORK
AutoCAD SHX Text
06
AutoCAD SHX Text
Revisions
AutoCAD SHX Text
M-1
AutoCAD SHX Text
3
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
18"x10"
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
REVIEW SET
AutoCAD SHX Text
EBB-X2
AutoCAD SHX Text
02
AutoCAD SHX Text
T
AutoCAD SHX Text
75
AutoCAD SHX Text
RELOCATE BASEBOARD HEATERS AS INDICATED IN NEW CONSTRUCTION DRAWING.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
10"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
DEMOLISH EXISTING DUCT MAIN/BRANCH SECTION AND DAMPERS ASSOCIATED WITH SEPARATING AHU-4-CC1/HC1 AND PREPARE FOR RELOCATION AS INDICATED IN NEW CONSTRUCTION.
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
T
AutoCAD SHX Text
EBB-X2
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
1200
AutoCAD SHX Text
750W
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
24"X24"
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
AHU-4-CC1 AHU-4-HC1
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
25"x10"
AutoCAD SHX Text
500W
AutoCAD SHX Text
4th FLOOR FLEX
AutoCAD SHX Text
25"x10"
AutoCAD SHX Text
STAMP/SEAL:
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
1. ALL NEW CEILING MOUNTED DIFFUSERS TO BE TYPE SD-1 UNLESS OTHERWISE NOTED. ALL NEW CEILING MOUNTED DIFFUSERS TO BE TYPE SD-1 UNLESS OTHERWISE NOTED. 2. CONTRACTOR TO ALLOW FOR THE RELOCATIONS OF EXISTING DIFFUSERS. CONTRACTOR TO ALLOW FOR THE RELOCATIONS OF EXISTING DIFFUSERS. 3. PROVIDE NEW RETURN GRILLES AS SHOWN. PROVIDE NEW RETURN GRILLES AS SHOWN. 4. DIFFUSER NECK SIDE TO MATCH BRANCH DUCT SIZE DIFFUSER NECK SIDE TO MATCH BRANCH DUCT SIZE 5. CONTRACTOR TO ALLOW FOR ULC LISTED FIRE STOPPING OF PIPING THOUGH ALL FIRE RATED CONTRACTOR TO ALLOW FOR ULC LISTED FIRE STOPPING OF PIPING THOUGH ALL FIRE RATED SEPARATIONS.
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
BIN
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
ISSUED FOR BP REVIEW
AutoCAD SHX Text
A
AutoCAD SHX Text
LEVEL 4
AutoCAD SHX Text
5
AutoCAD SHX Text
185
AutoCAD SHX Text
T
AutoCAD SHX Text
2
AutoCAD SHX Text
T
AutoCAD SHX Text
25"x10"
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
250
AutoCAD SHX Text
3
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
T
AutoCAD SHX Text
FCU-1X
AutoCAD SHX Text
3
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
2019/07/26
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
T
AutoCAD SHX Text
814 RICHARDS STREET
AutoCAD SHX Text
$2
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
RG-1
AutoCAD SHX Text
250
AutoCAD SHX Text
50
AutoCAD SHX Text
4
AutoCAD SHX Text
FC-4
AutoCAD SHX Text
EBB-1
AutoCAD SHX Text
24"X12"
AutoCAD SHX Text
1
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
1
AutoCAD SHX Text
2200
AutoCAD SHX Text
EBB-X2
AutoCAD SHX Text
175
AutoCAD SHX Text
19/07/26
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
1
AutoCAD SHX Text
D
AutoCAD SHX Text
20"x6"
AutoCAD SHX Text
CONTRACTOR TO PROVIDE AN ALTERNATE PRICE FOR THE INSTALLATION OF NEW HEATING AND COOLING COILS IN LIEU OF FAN COIL UNITS. HEATING AND COOLING COILS ARE TO BE INSTALLED COMPLETE WITH ALL ASSOCIATED ACCESSORIES, REFER TO DETAIL 6 ON DRAWING M-2. HEATING AND COOLING COILS ARE TO BE INSTALLED AS PER MANUFACTURERS RECOMMENDATIONS. ALLOW FOR THE MODIFICATION/EXTENSION OF CHILLED WATER AND HEATING WATER SUPPLY AND RETURN LINES. ALLOW FOR THE INSULATING OF NEW CHILLED WATER AND HEATING WATER LINES. CONTRACTOR TO ALLOW FOR THE MODIFICATION OF DUCTWORK AND FOR THE PROVISION OF NEW TRANSITIONS TO SUIT THE INSTALLATION OF COILS.
AutoCAD SHX Text
10"ø
AutoCAD SHX Text
19/08/23
AutoCAD SHX Text
2 PPL POD
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
200
AutoCAD SHX Text
20"x6"
AutoCAD SHX Text
TRANSFER DUCT 8"X6"
AutoCAD SHX Text
NO.
AutoCAD SHX Text
$1
AutoCAD SHX Text
2
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
BIN
AutoCAD SHX Text
10"ø
AutoCAD SHX Text
250
AutoCAD SHX Text
AHU-4-CC3 AHU-4-HC3
AutoCAD SHX Text
4
AutoCAD SHX Text
26"x10"
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
2
AutoCAD SHX Text
19/09/30
AutoCAD SHX Text
RELOCATE THERMOSTAT
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
3
AutoCAD SHX Text
1
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
3
AutoCAD SHX Text
T
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
10"x8"
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
10"ø
AutoCAD SHX Text
04
AutoCAD SHX Text
2 PPL POD
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
250
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
RTL
AutoCAD SHX Text
BIN
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
EBB-X1
AutoCAD SHX Text
C
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
16"x10"
AutoCAD SHX Text
10"ø
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
EBB-X1
AutoCAD SHX Text
T
AutoCAD SHX Text
$2
AutoCAD SHX Text
TRANSFER DUCT 8"X6"
AutoCAD SHX Text
75
AutoCAD SHX Text
DEMO & NEW
AutoCAD SHX Text
200
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
16"x6"
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
BIN
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
3
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
TYP@
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
25"x10"
AutoCAD SHX Text
STAIR # 1
AutoCAD SHX Text
25"x10"
AutoCAD SHX Text
INSTALLATION OF NEW FAN COIL UNIT COMPLETE WE ALL ASSOCIATED ACCESSORIES, REFER TO DETAIL A ON DRAWING M-0. FAN COIL UNITS TO BE INSTALLED AS PER MANUFACTURERS RECOMMENDATIONS. ALLOW FOR THE MODIFICATION/EXTENSION OF CHILLED WATER AND HEATING WATER SUPPLY AND RETURN LINES. ALLOW FOR THE INSULATED OF NEW CHILLED WATER AND HEATING WATER LINES. CONTRACTOR TO ALLOW FOR THE MODIFICATION OF DUCTWORK AND FOR THE PROVISION OF NEW TRANSITIONS TO SUIT THE INSTALLATION OF FAN COIL UNITS.
AutoCAD SHX Text
2
AutoCAD SHX Text
120
AutoCAD SHX Text
PROGRESS SET
AutoCAD SHX Text
500W
AutoCAD SHX Text
PHONE BOOTH
AutoCAD SHX Text
32"x16"
AutoCAD SHX Text
PRE-MEASURE
AutoCAD SHX Text
EBB-X1
AutoCAD SHX Text
185
AutoCAD SHX Text
BIN
AutoCAD SHX Text
ISSUED FOR TENDER REV.1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
EBB-2
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
$3
AutoCAD SHX Text
$1
AutoCAD SHX Text
T
AutoCAD SHX Text
BIN
AutoCAD SHX Text
UP
AutoCAD SHX Text
PRE-MEASURE
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
25"x10"
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
20"x10"
AutoCAD SHX Text
PRE-MEASURE
AutoCAD SHX Text
1
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
STAIR # 2
AutoCAD SHX Text
16"x6"
AutoCAD SHX Text
750W
AutoCAD SHX Text
EBB-2
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
26"x10"
AutoCAD SHX Text
3
AutoCAD SHX Text
T
AutoCAD SHX Text
20"x6"
AutoCAD SHX Text
Sheet Info.
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
BIN
AutoCAD SHX Text
5
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
1
AutoCAD SHX Text
50
AutoCAD SHX Text
1
AutoCAD SHX Text
M-1
AutoCAD SHX Text
10"ø
AutoCAD SHX Text
EBB-X2
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
20"x6"
AutoCAD SHX Text
BIN
AutoCAD SHX Text
140
AutoCAD SHX Text
3
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
SD-1
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
AHU-4-CC2 AHU-4-HC2
AutoCAD SHX Text
BIN
AutoCAD SHX Text
PRE-MEASURE
AutoCAD SHX Text
18"X8"
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
T
AutoCAD SHX Text
8"
AutoCAD SHX Text
Copyright C 2008 Flow Consulting Group Inc.
AutoCAD SHX Text
200
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
TYP@
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
10"ø
AutoCAD SHX Text
03
AutoCAD SHX Text
19/08/16
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
5
AutoCAD SHX Text
175
AutoCAD SHX Text
3
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
500W
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
1. DEMOLISH ALL EXISTING RETURN AIR GRILLES IN CEILING SPACE. DEMOLISH ALL EXISTING RETURN AIR GRILLES IN CEILING SPACE. 2. DEMOLISH XFC-4-2, XFC-4-4, FCU-1X AND ASSOCIATED ROOFTOP CONDENSING UNITS, REFRIGERANT DEMOLISH XFC-4-2, XFC-4-4, FCU-1X AND ASSOCIATED ROOFTOP CONDENSING UNITS, REFRIGERANT PIPING, CONTROLS/ELECTRICAL WIRING. PATCH AND MAKE GOOD ROOF AND WALLS AFFECTED BY WORK. 3. RELOCATE DIFFUSERS AS SHOWN.RELOCATE DIFFUSERS AS SHOWN.
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
CORRIDOR #2
AutoCAD SHX Text
3
AutoCAD SHX Text
TYP@
AutoCAD SHX Text
185
AutoCAD SHX Text
FC-5
AutoCAD SHX Text
CONTRACTOR TO COORDINATE NEW THERMOSTAT LOCATIONS WITH NEW DIRTT WALL SYSTEM. CAP EXISTING DEMOLISHED DUCTWORK COMPLETE WITH HIGH PRESSURE MASTIC. PROVIDE NEW TRANSFER AIR DUCTS AS SHOWN COMPLETE WITH 1" ACOUSTIC DUCT LINER. REFER TO INSTALLATION DETAIL ON DRAWING M-3 CONTRACTOR TO PROVIDE TRAVERSE AIR READING OF FRESH AIR SUPPLY TO THIS FLOORS AIR HANDLING UNIT. CONTRACTOR TO PROVIDE SMOKE/FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH CORRIDOR PARTITION. CONTRACTOR TO ALL FOR DUCT MODIFICATION TO SUIT TO PROVISION OF PROTECTIVE DEVICES. CONTRACTOR TO REFER TO ARCHITECTURAL/CODE CONSULTANT FOR SEPARATION RATING
AutoCAD SHX Text
$2
AutoCAD SHX Text
185
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
750W
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
16"x6"
AutoCAD SHX Text
20"x10"
AutoCAD SHX Text
14"x10"
AutoCAD SHX Text
NOT IN SCOPE
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
200
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
$1
AutoCAD SHX Text
05
AutoCAD SHX Text
$A
AutoCAD SHX Text
DEMOLISH EXISTING WINDOW MOUNTED FAN AND CONTROLS
AutoCAD SHX Text
%%U PARTIAL 4TH FLOOR PLAN - HVAC DEMOLITION
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
20"x6"
AutoCAD SHX Text
RELOCATE EXISTING DUCT ALONG WALL AS INDICATED IN NEW CONSTRUCTION DRAWINGS TO PROVIDE CLEARANCES FOR NEW INSTALLATIONS.
AutoCAD SHX Text
25"x10"
AutoCAD SHX Text
PRE-MEASURE
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
1
AutoCAD SHX Text
$3
AutoCAD SHX Text
20"x6"
AutoCAD SHX Text
$1
AutoCAD SHX Text
PRE-MEASURE
AutoCAD SHX Text
T
AutoCAD SHX Text
3
AutoCAD SHX Text
BIN
AutoCAD SHX Text
1000
AutoCAD SHX Text
T
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
PRE-MEASURE
AutoCAD SHX Text
$3
AutoCAD SHX Text
500W
AutoCAD SHX Text
200
AutoCAD SHX Text
$2
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
250
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
RELOCATE EXISTING DUCT IF REQUIRED TO SUIT NEW DIRTT WALL HANGERS NOTE: FC-1 & FC-3 ARE PROVIDED AS PER BASE BUILDING REQUEST VIA HONEYWELL. UNITS ARE FC-1 & FC-3 ARE PROVIDED AS PER BASE BUILDING REQUEST VIA HONEYWELL. UNITS ARE SIZED BASED ON RECEIVED AIR VALUES FROM HONEYWELL. NO EXISTING DESIGN INFORMATION IS AVAILABLE. CONTRACTOR IS TO PRE-MEASURE AND CONFIRM EXISTING AIR VOLUMES TO ADJACENT TENANT SPACES. CONTRACTOR TO ENSURE EXISTING AIR VALUES ARE REESTABLISHED AT END OF JOB.
AutoCAD SHX Text
DN
AutoCAD SHX Text
TL
AutoCAD SHX Text
TO AHU-4-CC1
AutoCAD SHX Text
RTL
AutoCAD SHX Text
75
AutoCAD SHX Text
1
AutoCAD SHX Text
01
AutoCAD SHX Text
DN
AutoCAD SHX Text
30"x10"
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
250
AutoCAD SHX Text
ISSUED FOR BP/TENDER
AutoCAD SHX Text
750W
AutoCAD SHX Text
T
AutoCAD SHX Text
60
AutoCAD SHX Text
500W
AutoCAD SHX Text
AHU-4-CC2 AHU-4-HC2
AutoCAD SHX Text
NOT IN SCOPE
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
PHONE BOOTH
AutoCAD SHX Text
750W
AutoCAD SHX Text
175
AutoCAD SHX Text
ISSUED FOR TENDER
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
1
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
160
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
EBB-X1
AutoCAD SHX Text
750W
AutoCAD SHX Text
$1
AutoCAD SHX Text
10"ø
AutoCAD SHX Text
26"x10"
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
PRE-MEASURE
AutoCAD SHX Text
160
AutoCAD SHX Text
750W
AutoCAD SHX Text
DEMOLISH EXISTING AHU-4-CC1/HC1, AHU-4-CC3/HC3 AND ALL ASSOCIATED PIPING, CONTROLS AND CONDENSATE DRAINAGE.
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
T
AutoCAD SHX Text
175
AutoCAD SHX Text
TO XFC-4-3
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
FC-1
AutoCAD SHX Text
PHONE BOOTH
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
1
AutoCAD SHX Text
PRE-MEASURE
AutoCAD SHX Text
TRANSFER DUCT 16"X10"
AutoCAD SHX Text
19/09/18
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
19-115
AutoCAD SHX Text
6"ø
AutoCAD SHX Text
Project:
AutoCAD SHX Text
500W
AutoCAD SHX Text
2
AutoCAD SHX Text
32"x16"
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
EBB-X1
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
T
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
1000
AutoCAD SHX Text
250
AutoCAD SHX Text
16"x6"
AutoCAD SHX Text
B
AutoCAD SHX Text
3
AutoCAD SHX Text
1
AutoCAD SHX Text
EBB-2
AutoCAD SHX Text
T
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
Title
AutoCAD SHX Text
10"x6"
AutoCAD SHX Text
175
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
185
AutoCAD SHX Text
MAIN ENTRY
AutoCAD SHX Text
MEN'S WC EXISTING
AutoCAD SHX Text
26"x6"
AutoCAD SHX Text
5
AutoCAD SHX Text
PRE-MEASURE
AutoCAD SHX Text
FC-3
AutoCAD SHX Text
250
AutoCAD SHX Text
$1
AutoCAD SHX Text
CORRIDOR #1
AutoCAD SHX Text
WOMEN'S WC EXISTING
AutoCAD SHX Text
14"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
8"ø
AutoCAD SHX Text
2
AutoCAD SHX Text
26"x10"
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
250
AutoCAD SHX Text
6
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
$3
AutoCAD SHX Text
DEMOLISHED INSTALLED DUCT THAT APPEARS TO BE A 10"ø RELIEF AIR DUCT. CONTRACTOR TO CONFIRM THE EXISTENCE OF ANY FANS, DUCT HEATERS OR BACKDRAFT DAMPERS ASSOCIATED WITH THIS DUCT. PATCH AND MAKE GOOD EXISTING ROOF PENETRATION. CONTRACTOR TO RETAIN APPROVED BALANCING AGENT TO PRE-MEASURE AIR FLOWS PRIOR TO THE START OF WORK. BALANCING AGENT IS TO RE-ESTABLISH MEASURED AIR FLOWS DURING FINAL BALANCING OF SYSTEM. PRE-MEASURED AND FINAL MEASURED AIR VALUES TO BE INCLUDED IN FINAL BALANCING REPORT.
AutoCAD SHX Text
250
AutoCAD SHX Text
INSTALL NEW DUCT TRANSITIONS AND BALANCING DAMPERS TO SUIT CORRIDOR LOCATIONS OF NEW ZONE COILS
AutoCAD SHX Text
EBB-X1
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
VANCOUVER, BC
Page 7: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

24'-10" 24'-10" 16'-10"

COLLAB.

COLLAB.

COLLAB.

EXT'G CORRIDOR

403.1

EX SERVICE

EX WOMEN'S

EX MEN'S

403.2

405

STAIR # 2

OPEN

OFFICE

407

OPEN

OFFICE

406

OPEN

OFFICE

408

OPEN

OFFICE

409

OPEN

OFFICE

410

OPEN

OFFICE

411

COPY/PRT.

413

BREAKOUT RM.

414

OFFICE

415

OFFICE

416

4 5 6

4 5 6

DEMOLITION KEYED NOTES

NORTHNORTH

SHELF

TASK

CHAIR

54"x36"

SIT/STAND

84"x30"

TABLE

MOBILE

PED B/B/F

GUEST

CHAIR

GUEST

CHAIR

30x48

30x48

24x48 24x48 24x48

TASK

CHAIR

FILE/FILE/FILE

24"x24"x62.5" HIGH

950 Series

PER. STORAGE TOWER

VALET

48"x36"

SIT/STAND

TASK

CHAIR

FILE/FILE/FILE

24"x24"x62.5" HIGH

950 Series

PER. STORAGE TOWER

VALET

48"x36"

SIT/STAND

24x48 24x48

24x48 24x48

S

H

E

L

F

6

0

"

x

2

4

"

T

A

B

L

E

MOBILE PED

B/B/F

TASK

CHAIR

FILE/FILE/FILE

24"x24"x62.5" HIGH

950 Series

PER. STORAGE TOWER

VALET

6

0

"

x

3

0

"

T

A

B

L

E

6

0

"

x

2

4

"

T

A

B

L

E

48"x36"

SIT/STAND

3

0

"

S

H

E

L

F

MOBILE PED

B/B/F

TASK

CHAIR

FILE/FILE/FILE

24"x24"x62.5" HIGH

950 Series

PER. STORAGE TOWER

VALET

48"x36"

SIT/STAND

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

24x4824x4824x48

24x4824x4824x48

S

H

E

L

F

6

0

"

x

2

4

"

T

A

B

L

E

MOBILE PED

B/B/F

TASK

CHAIR

FILE/FILE/FILE

24"x24"x62.5" HIGH

950 Series

PER. STORAGE TOWER

VALET

6

0

"

x

3

0

"

T

A

B

L

E

6

0

"

x

2

4

"

T

A

B

L

E

48"x36"

SIT/STAND

3

0

"

S

H

E

L

F

MOBILE PED

B/B/F

TASK

CHAIR

FILE/FILE/FILE

24"x24"x62.5" HIGH

950 Series

PER. STORAGE TOWER

VALET

48"x36"

SIT/STAND

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

24x4824x4824x48

24x4824x4824x48

30x48

30x48

24x4824x4824x48

30x48

30x48

24x4824x4824x48

30x48

30x48

24x4824x4824x48

3

0

x

4

8

3

0

x

4

8

24x48 24x48 24x48

30x48

30x48

24x4824x4824x48

3

0

x

4

8

3

0

x

4

8

24x4824x4824x48

3

0

x

4

8

3

0

x

4

8

24x48 24x48 24x48

30x48

30x48

3

0

x

4

8

3

0

x

4

8

F2

30x48

30x48

24x48 24x48 24x48

3

0

x

4

8

3

0

x

4

8

24x48 24x48 24x48

30x48

30x48

24x48 24x48 24x48

MOBILE PED

B/B/F

MOBILE PED

B/B/F

TA

BLE

60"x30"

30x48

30x48

30x48

30x48

24x4824x4824x48

3

0

x

4

8

3

0

x

4

8

24x4824x4824x48

3

0

x

4

8

3

0

x

4

8

24x48 24x48 24x48

MOBILE PED

B/B/F

MOBILE PED

B/B/F

TA

BLE

60"x30"

30x48

30x48

30x48

30x48

24x4824x4824x48

3

0

x

4

8

3

0

x

4

8

24x4824x4824x48

24x48 24x48

30x48

30x48

24x4824x4824x48

S

H

E

L

F

6

0

"

x

2

4

"

T

A

B

L

E

MOBILE PED

B/B/F

TASK

CHAIR

FILE/FILE/FILE

24"x24"x62.5" HIGH

950 Series

PER. STORAGE TOWER

VALET

6

0

"

x

3

0

"

T

A

B

L

E

6

0

"

x

2

4

"

T

A

B

L

E

48"x36"

SIT/STAND

3

0

"

S

H

E

L

F

MOBILE PED

B/B/F

TASK

CHAIR

FILE/FILE/FILE

24"x24"x62.5" HIGH

950 Series

PER. STORAGE TOWER

VALET

48"x36"

SIT/STAND

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

3

0

x

4

8

24x4824x4824x48

24x4824x4824x48

30x48

30x48

24x4824x4824x48

SH

ELF

60"x24"

TA

BLE

MOBILE PED

B/B/F

TASK

CHAIR

FILE/FILE/FILE

24"x24"x62.5" HIGH

950 Series

PER. STORAGE TOWER

VALET

60"x30"

TA

BLE

60"x24"

TA

BLE

48"x36"

SIT/STAND

30"

SH

ELF

MOBILE PED

B/B/F

TASK

CHAIR

FILE/FILE/FILE

24"x24"x62.5" HIGH

950 Series

PER. STORAGE TOWER

VALET

48"x36"

SIT/STAND

30x48

30x48

30x48

30x48

30x48

30x48

24x48 24x48 24x48

24x48 24x48 24x48

EMERG.

CABINET

3 4 5

3 4 5

NEW CONSTRUCTION KEYED NOTES

NORTHNORTH

SEPARATE PRICE

This drawing is the property of the Designer andmay not be reproduced or used without theexpressed consent of the Designer. Allinformation shown on this drawings is for use onthis project only and shall not be usedotherwise. The Contractor is responsible forchecking and verifying all levels and dimensionsand shall report all discrepancies to theDesigner and obtain clarification prior tocommencing work. Do not scale the drawings.

flow consulting group inc.#1080 - 1075 west georgia streetvancouver, b.c. V6E 3C9v. 604 609 0500 f. 604 609 0588

C O N S U L T I N G

AutoCAD SHX Text
NO LABOR COLLAR.
AutoCAD SHX Text
TYPICAL 50 WIDE COLOUR CODED TAPE
AutoCAD SHX Text
CLEVIS HANGER
AutoCAD SHX Text
OwnerHistory
AutoCAD SHX Text
24x48
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
2. DETAIL CAN BE USED FOR
AutoCAD SHX Text
PETE'S PLUG
AutoCAD SHX Text
3.8
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
RD - 032
AutoCAD SHX Text
REFER TO SPEC.
AutoCAD SHX Text
%%U PIPE IDENTIFICATION DETAIL
AutoCAD SHX Text
Sheet Info.
AutoCAD SHX Text
%%uNOTES
AutoCAD SHX Text
F3
AutoCAD SHX Text
24x48
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
24x48
AutoCAD SHX Text
AIR
AutoCAD SHX Text
Title
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
408
AutoCAD SHX Text
Copyright C 2008 Flow Consulting Group Inc.
AutoCAD SHX Text
M-2
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
PHONE BOOTH
AutoCAD SHX Text
Name
AutoCAD SHX Text
7
AutoCAD SHX Text
BIN
AutoCAD SHX Text
24x48
AutoCAD SHX Text
PROGRESS SET
AutoCAD SHX Text
RepresentationMaps
AutoCAD SHX Text
(WRAP A MINIMUM OF 1-1/2 TIMES AROUND
AutoCAD SHX Text
DEMOLISH CONDENSATE PIPING FROM FCUS LABELED FOR DEMOLITION
AutoCAD SHX Text
HANGER ROD
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
ApplicableOccurrence
AutoCAD SHX Text
3.8
AutoCAD SHX Text
M-2
AutoCAD SHX Text
24x48
AutoCAD SHX Text
%%UVAPOUR SEALED INSULATION
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
24x48
AutoCAD SHX Text
PETE'S PLUG
AutoCAD SHX Text
OPEN OFFICE
AutoCAD SHX Text
PHONE BOOTH
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
M-2
AutoCAD SHX Text
REPAIR EXISTING DUCTWORK CONNECTIONS TO DIFFUSERS AS PER DETAIL 2/M-3. ALLOW FOR 30% OF EXISTING DUCT CONNECTIONS TO BE REPAIRED.
AutoCAD SHX Text
REFRIGERATOR
AutoCAD SHX Text
AHU-4-CC2
AutoCAD SHX Text
RD - 017
AutoCAD SHX Text
24x48
AutoCAD SHX Text
BIN
AutoCAD SHX Text
COPIER
AutoCAD SHX Text
RD - 019
AutoCAD SHX Text
412
AutoCAD SHX Text
24x48
AutoCAD SHX Text
1
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
OPEN OFFICE
AutoCAD SHX Text
24x48
AutoCAD SHX Text
3
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
RD - 011
AutoCAD SHX Text
VAPOUR SEAL PREFORMED
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
$1
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
28
AutoCAD SHX Text
JOINT AIR TIGHT.
AutoCAD SHX Text
24x48
AutoCAD SHX Text
3.8
AutoCAD SHX Text
8
AutoCAD SHX Text
7
AutoCAD SHX Text
ISSUED FOR TENDER REV.1
AutoCAD SHX Text
NO.
AutoCAD SHX Text
1KcEo7H2DEFxom$DGf5CmK
AutoCAD SHX Text
POSITION IF DAMPER CAN
AutoCAD SHX Text
ENSURE PERMANENT ADHESION
AutoCAD SHX Text
24x48
AutoCAD SHX Text
FC-3
AutoCAD SHX Text
VENT
AutoCAD SHX Text
PIPE INSULATION. REFER
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
4
AutoCAD SHX Text
2 PPL POD
AutoCAD SHX Text
NOT BE LOCATED NEAR
AutoCAD SHX Text
WORK PROJECT
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
RTL
AutoCAD SHX Text
M-2
AutoCAD SHX Text
PITCH
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
F3
AutoCAD SHX Text
Revisions
AutoCAD SHX Text
0
AutoCAD SHX Text
16403
AutoCAD SHX Text
%%U EXISTING RELIEF AIR DUCT
AutoCAD SHX Text
TO SPEC.
AutoCAD SHX Text
HasPropertySets
AutoCAD SHX Text
CHILLED WATER
AutoCAD SHX Text
FACTORY
AutoCAD SHX Text
ApplicableOccurrence
AutoCAD SHX Text
NEW 1-1/2"ø SAN TO DROP INTO FLOOR BELOW. ALLOW FOR SCANNING, CORING AND FIRE STOPPING OF FLOOR.
AutoCAD SHX Text
{1B614378-7903-4245-9B07-E9414EBF149E}
AutoCAD SHX Text
9
AutoCAD SHX Text
OPEN OFFICE
AutoCAD SHX Text
24x48
AutoCAD SHX Text
PARTIAL 4TH FLOOR PLAN - PLUMBING NEW WORK
AutoCAD SHX Text
INFORMAL MEETING SPACE
AutoCAD SHX Text
7
AutoCAD SHX Text
24x48
AutoCAD SHX Text
SQUARE TO ROUND
AutoCAD SHX Text
OPEN OFFICE
AutoCAD SHX Text
Tag
AutoCAD SHX Text
F3
AutoCAD SHX Text
RD - 026
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
1
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
$1
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
3-WAY CONTROL VALVE
AutoCAD SHX Text
410
AutoCAD SHX Text
1 DIA
AutoCAD SHX Text
24x48
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
7
AutoCAD SHX Text
DEMO & NEW
AutoCAD SHX Text
24x48
AutoCAD SHX Text
RD - 033
AutoCAD SHX Text
F
AutoCAD SHX Text
SUPPORT NUT
AutoCAD SHX Text
7
AutoCAD SHX Text
%%U EXISTING FCU CONDENSATE DRAINAGE
AutoCAD SHX Text
SUPPORT NUT
AutoCAD SHX Text
Refrigerator 83 x 180 x 73mm
AutoCAD SHX Text
RD - 037
AutoCAD SHX Text
PIPE INSULATION
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
BIN
AutoCAD SHX Text
%%U PIPE HANGERS
AutoCAD SHX Text
16412
AutoCAD SHX Text
RD - 022
AutoCAD SHX Text
24x48
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
M-2
AutoCAD SHX Text
409
AutoCAD SHX Text
24x48
AutoCAD SHX Text
[50%%DF] OR LESS.
AutoCAD SHX Text
INSULATION.
AutoCAD SHX Text
Tag
AutoCAD SHX Text
24x48
AutoCAD SHX Text
ISSUED FOR BP REVIEW
AutoCAD SHX Text
19/08/16
AutoCAD SHX Text
MAIN ENTRY
AutoCAD SHX Text
OPEN OFFICE
AutoCAD SHX Text
RD - 016
AutoCAD SHX Text
7
AutoCAD SHX Text
5
AutoCAD SHX Text
HasPropertySets
AutoCAD SHX Text
BIN
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
RTL
AutoCAD SHX Text
TITUS AG-75 OR EQUAL
AutoCAD SHX Text
19-115
AutoCAD SHX Text
$1
AutoCAD SHX Text
16391
AutoCAD SHX Text
24x48
AutoCAD SHX Text
3.8
AutoCAD SHX Text
CIRCUIT BALANCING VALVE
AutoCAD SHX Text
2
AutoCAD SHX Text
24x48
AutoCAD SHX Text
M-2
AutoCAD SHX Text
MIN ONE PER SIDE. SEAL
AutoCAD SHX Text
19/09/18
AutoCAD SHX Text
RD - 031
AutoCAD SHX Text
GlobalId
AutoCAD SHX Text
M-2
AutoCAD SHX Text
APPLY A CONTINUOUS COATING OF CONTACT CEMENT TO THE LABEL TO
AutoCAD SHX Text
FC-1
AutoCAD SHX Text
24x48
AutoCAD SHX Text
HOT WATER SUPPLY
AutoCAD SHX Text
24x48
AutoCAD SHX Text
RD - 023
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
TO SPEC.
AutoCAD SHX Text
3.8
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
STAIR # 2
AutoCAD SHX Text
24x48
AutoCAD SHX Text
16412
AutoCAD SHX Text
HEATING COIL
AutoCAD SHX Text
CAP W/ SHT MTL SCREWS,
AutoCAD SHX Text
BIN
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
PHONE BOOTH
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
EXTEND 25 IN TO TAPE
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
10
AutoCAD SHX Text
1
AutoCAD SHX Text
BIN
AutoCAD SHX Text
FC-5
AutoCAD SHX Text
1. PROVIDE SUPPORT FOR
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
{ADCCCE90-7636-4CE4-9D25-2E439DBAF036}
AutoCAD SHX Text
F3
AutoCAD SHX Text
FC-4
AutoCAD SHX Text
19/08/23
AutoCAD SHX Text
3
AutoCAD SHX Text
DEMOLISH EXISTING DUCTWORK AND ASSOCIATED EQUIPMENT. PATCH AND MAKE GOOD DAMAGED CEILING.
AutoCAD SHX Text
814 RICHARDS STREET
AutoCAD SHX Text
414
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
M-2
AutoCAD SHX Text
24x48
AutoCAD SHX Text
OPPOSED BLADE DAMPER
AutoCAD SHX Text
M-2
AutoCAD SHX Text
M-2
AutoCAD SHX Text
24x48
AutoCAD SHX Text
%%U CHILLED WATER COIL CONNECTION DETAIL
AutoCAD SHX Text
2
AutoCAD SHX Text
LOCKING NUT
AutoCAD SHX Text
CLEVIS HANGER
AutoCAD SHX Text
24x48
AutoCAD SHX Text
LINER TAUT.
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
16391
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
COOLING COIL
AutoCAD SHX Text
DEMOLISH EXISTING CONDENSATE PIPING FROM FCUS LABELED FOR DEMOLITION. RETAIN EXISTING CONDENSATE PIPING FROM REMAINING FCUS AND COLD WATER COILS
AutoCAD SHX Text
19
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
FOR NPS 2 1/2 [65mm] PIPE AND
AutoCAD SHX Text
7
AutoCAD SHX Text
3-WAY CONTROL VALVE
AutoCAD SHX Text
Project:
AutoCAD SHX Text
SAME SIZE AS FLEX DUCT.
AutoCAD SHX Text
24x48
AutoCAD SHX Text
ElementType
AutoCAD SHX Text
HANGER DETAIL FOR INSULATED HOT PIPING
AutoCAD SHX Text
24x48
AutoCAD SHX Text
OwnerHistory
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
Description
AutoCAD SHX Text
24x48
AutoCAD SHX Text
LEVEL 4
AutoCAD SHX Text
INFORMAL MEETING SPACE
AutoCAD SHX Text
CONCENTRIC REDUCER
AutoCAD SHX Text
DRAIN PORT
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
24x48
AutoCAD SHX Text
2
AutoCAD SHX Text
COLLAB.
AutoCAD SHX Text
2
AutoCAD SHX Text
ElementType
AutoCAD SHX Text
0
AutoCAD SHX Text
24x48
AutoCAD SHX Text
Tag
AutoCAD SHX Text
AHU-4-CC3
AutoCAD SHX Text
RD - 020
AutoCAD SHX Text
F3
AutoCAD SHX Text
GlobalId
AutoCAD SHX Text
KS-1
AutoCAD SHX Text
ISSUED FOR BP/TENDER
AutoCAD SHX Text
%%U LAY-IN CEILING DIFFUSER
AutoCAD SHX Text
$1
AutoCAD SHX Text
NOT IN SCOPE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
4
AutoCAD SHX Text
WOMEN'S WC EXISTING
AutoCAD SHX Text
24x48
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
RD - 034
AutoCAD SHX Text
16391
AutoCAD SHX Text
RIGID DUCT.
AutoCAD SHX Text
5
AutoCAD SHX Text
LOCKING NUT
AutoCAD SHX Text
TL
AutoCAD SHX Text
3.8
AutoCAD SHX Text
24x48
AutoCAD SHX Text
6
AutoCAD SHX Text
24x48
AutoCAD SHX Text
REVIEW SET
AutoCAD SHX Text
Description
AutoCAD SHX Text
DIFFUSER & CAP PER
AutoCAD SHX Text
MEN'S WC EXISTING
AutoCAD SHX Text
3
AutoCAD SHX Text
Refrigerator 83 x 180 x 73mm
AutoCAD SHX Text
TYPICAL CONTINUOUS PIPE IDENTIFICATION
AutoCAD SHX Text
2019/07/26
AutoCAD SHX Text
1
AutoCAD SHX Text
24x48
AutoCAD SHX Text
RD - 013
AutoCAD SHX Text
16391
AutoCAD SHX Text
CONCENTRIC REDUCER
AutoCAD SHX Text
19/09/30
AutoCAD SHX Text
CODE.
AutoCAD SHX Text
F3
AutoCAD SHX Text
4
AutoCAD SHX Text
24x48
AutoCAD SHX Text
1
AutoCAD SHX Text
DRAIN PAN
AutoCAD SHX Text
7
AutoCAD SHX Text
19/07/26
AutoCAD SHX Text
16385
AutoCAD SHX Text
1
AutoCAD SHX Text
24x48
AutoCAD SHX Text
CLG DIFFUSER. FASTEN TO
AutoCAD SHX Text
OPEN OFFICE
AutoCAD SHX Text
REFER TO SPECIFICATION FOR COLOUR CODING OF SERVICES & INSTALLATION
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
BY G.C. WHEN REQ'D.
AutoCAD SHX Text
24x48
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
0ROKDuUGD2HPi7wK5ElnIU
AutoCAD SHX Text
CONNECT NEW 1-1/2"ø SAN PIPING TO BASE WASHROOM RISER STACKS IN FLOOR BELOW.
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
COPIER
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
24x48
AutoCAD SHX Text
4th FLOOR FLEX
AutoCAD SHX Text
INSERTS OR HIGH DENSITY
AutoCAD SHX Text
ROUND INSUL STUB DUCT
AutoCAD SHX Text
1
AutoCAD SHX Text
RD - 035
AutoCAD SHX Text
AIR
AutoCAD SHX Text
BRANCH TAKEOFF).
AutoCAD SHX Text
CONNECT NEW 1/2"ø DCW/DHW & 1-1/4"ø VENT PIPING TO EXISTING CAPPED CONNECTIONS IN TENANT SPACE.
AutoCAD SHX Text
BIN
AutoCAD SHX Text
VENT
AutoCAD SHX Text
16391
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
24x48
AutoCAD SHX Text
3.8
AutoCAD SHX Text
40
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
4
AutoCAD SHX Text
24x48
AutoCAD SHX Text
%%U HEATING WATER COIL CONNECTION DETAIL
AutoCAD SHX Text
VANCOUVER, BC
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
FLEX DUCT CLAMP.
AutoCAD SHX Text
REFRIGERATOR
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
24x48
AutoCAD SHX Text
HANGER ROD
AutoCAD SHX Text
8
AutoCAD SHX Text
DRAIN PORT
AutoCAD SHX Text
GlobalId
AutoCAD SHX Text
1
AutoCAD SHX Text
8
AutoCAD SHX Text
REFER TO SPEC.
AutoCAD SHX Text
BIN
AutoCAD SHX Text
DATE INSTALLED
AutoCAD SHX Text
CIRCUIT BALANCING VALVE
AutoCAD SHX Text
ElementType
AutoCAD SHX Text
MARKER & DIRECTION OF FLOW ARROW TO
AutoCAD SHX Text
M-2
AutoCAD SHX Text
UP TO NPS 3 (75mm) OR ALL SIZES OF BARE PIPE
AutoCAD SHX Text
FOR COLD PIPING 10%%DC
AutoCAD SHX Text
ISSUED FOR TENDER
AutoCAD SHX Text
RD - 025
AutoCAD SHX Text
PREFORMED PIPE INSULATION
AutoCAD SHX Text
16385
AutoCAD SHX Text
FLEX DUCT. PULL INSIDE
AutoCAD SHX Text
RepresentationMaps
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
RD - 018
AutoCAD SHX Text
TYP SUSP LAY-IN CEILING.
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
PARTIAL 4TH FLOOR PLAN - PLUMBING DEMOLITION
AutoCAD SHX Text
16403
AutoCAD SHX Text
BIN
AutoCAD SHX Text
RD - 030
AutoCAD SHX Text
FAN COIL CONDENSATE DRAINS TO DRAIN UP-STREAM OF SINK P-TRAP AS SHOWN. CONDENSATE LINES ARE TO BE INSULATED.
AutoCAD SHX Text
BIN
AutoCAD SHX Text
CORRIDOR #2
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
6
AutoCAD SHX Text
OPEN MEETING
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
BIN
AutoCAD SHX Text
24x48
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
16391
AutoCAD SHX Text
RepresentationMaps
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
RD - 029
AutoCAD SHX Text
24x48
AutoCAD SHX Text
RD - 024
AutoCAD SHX Text
PIPE)
AutoCAD SHX Text
HasPropertySets
AutoCAD SHX Text
BIN
AutoCAD SHX Text
0
AutoCAD SHX Text
NOTE: ULC/CSA APPROVED ASSEMBLY
AutoCAD SHX Text
24x48
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
16391
AutoCAD SHX Text
Description
AutoCAD SHX Text
16391
AutoCAD SHX Text
6'8"
AutoCAD SHX Text
LARGER. REFER TO SPEC. FOR
AutoCAD SHX Text
PredefinedType
AutoCAD SHX Text
RD - 015
AutoCAD SHX Text
PredefinedType
AutoCAD SHX Text
RD - 027
AutoCAD SHX Text
1
AutoCAD SHX Text
Name
AutoCAD SHX Text
2
AutoCAD SHX Text
SUPPLY OR RETURN
AutoCAD SHX Text
REMOVE EXISTING SINK AND ASSOCIATED PIPING. CUT AND CAP DOMESTIC WATER AND VENT CONNECTIONS AT SUITE PENETRATION AND PREPARE FOR RECONNECTION. CUT AND CAP DRAINAGE PIPING BACK TO NEAREST CONNECTION BELOW SLAB. PATCH AND MAKE GOOD SLAB.
AutoCAD SHX Text
8
AutoCAD SHX Text
24x48
AutoCAD SHX Text
24x48
AutoCAD SHX Text
%%U EXISTING DIFFUSER CONNECTIONS
AutoCAD SHX Text
3.8
AutoCAD SHX Text
7
AutoCAD SHX Text
SHIELD AT HANGER. REFER
AutoCAD SHX Text
40
AutoCAD SHX Text
24x48
AutoCAD SHX Text
%%UHANGER DETAIL FOR PIPING WITH
AutoCAD SHX Text
16391
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
Name
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
ApplicableOccurrence
AutoCAD SHX Text
3.8
AutoCAD SHX Text
OwnerHistory
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
(ONLY LOCATE IN THIS
AutoCAD SHX Text
{5498EC87-4423-4E3F-BCB0-FCD42914CC14}
AutoCAD SHX Text
IF REQ'D. REFER TO
AutoCAD SHX Text
RD - 028
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
$1
AutoCAD SHX Text
3.8
AutoCAD SHX Text
24x48
AutoCAD SHX Text
BIN
AutoCAD SHX Text
24x48
AutoCAD SHX Text
AssemblyPlace
AutoCAD SHX Text
24x48
AutoCAD SHX Text
$1
AutoCAD SHX Text
16391
AutoCAD SHX Text
DATE
AutoCAD SHX Text
RD - 036
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
3. F&I EARTHQUAKE SUPPORT PER A.H.J.
AutoCAD SHX Text
SUPPLY OR RETURN.
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
24x48
AutoCAD SHX Text
EXISTING FCU CONDENSATE P-TRAP.
AutoCAD SHX Text
STAMP/SEAL:
AutoCAD SHX Text
INSULATION PROTECTION
AutoCAD SHX Text
$1
AutoCAD SHX Text
24x48
AutoCAD SHX Text
19/10/30
AutoCAD SHX Text
411
AutoCAD SHX Text
3'0"
AutoCAD SHX Text
COLLAB.
AutoCAD SHX Text
RD - 021
AutoCAD SHX Text
6'8"
Page 8: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

ServiceDesign

OperatingTemperature

ConductivityBtu∙in./(h∙ft2∙°F)

Nominal Pipe Size (in)

<1 1 to < 1½

1 ½ to< 4 4 to < 8

8 andlarger

Hot Water 40-60°C[105-140°F]

0.22-0.28 25[1]

25[1]

40[1.5]

40[1.5]

40[1.5]

Hot Water 60-90°C[141-200°F]

0.25-0.29 40[1.5]

40[1.5]

50[2]

50[2]

50[2]

Chilled Water,Condensate

Drains, DomesticCold Water,Irrigation,

Storm/RWL

4.5-15.5°C[40-60°F]

0.21-0.27 25[1]

25[1]

25[1]

25[1]

25[1]

1. General

1.1. Intent

1.1.1. The intent of this specification and the drawings is to provide a complete and fully operationalmechanical system in complete accord with applicable codes. The Mechanical Contractor shallmake provisions for labour, material, and equipment necessary to complete the mechanical work.

1.1.2. The word "provide" shall mean "supply and install" the products and services specified. "asindicated" means that the item(s) specified are shown on the drawings.

1.1.3. Drawings and specifications are complementary to each other and what is called for in one isbinding as if called for in both. Should any discrepancy appear between drawings andspecifications which leaves doubt as to the true intent and meaning, obtain a ruling from theengineer ten (10) days before submitting tender. Failing this, allow for most expensive alternative.

1.1.4. Contract documents are diagrammatic only. They are to establish scope, material and quality.They are not detailed installation drawings. Minor details usually not shown or specified and anyincidental accessories required for proper installation of the system are to be included in the work.

1.1.5. The Mechanical Contractor is to ensure that all intended equipment will fit within given spaces.Make reference to the electrical, mechanical, architectural and structural drawings, when settingout work and before ordering equipment.

1.1.6. The Mechanical Contractor shall visit the site before tendering. Examine all local and existingconditions on which the work is dependent. No consideration will be granted for anymisunderstanding, of work to be done, resulting from failure to visit the site.

1.2. Codes, regulations and standards

1.2.1. All work shall conform to current editions of national, provincial and municipal codes, standardsand other legal regulations and bylaws applicable to the work and will meet the requirements ofauthorities having jurisdiction.

1.3. Certificates

1.3.1. Give notices, obtain all required permits and approvals, and pay all fees so work specified may becarried out. Furnish certificates if requested, as evidence that work conforms to laws andregulations of the authorities having jurisdiction.

1.4. Guarantee

1.4.1. Provide the owner with a written guarantee that the equipment installed and the work performedshall remain in a serviceable condition for a period of one (1) year from the date of finalacceptance by the owner. The warranty shall cover material as well as labor.

1.5. Responsibilities

1.5.1. Assume responsibility for layout of work; and for any damage caused to the owner or othertenants by improper execution of work.

1.5.2. Protect all new and existing work from damage.

1.5.3. Take responsibility for condition of materials and equipment supplied and protect until work iscompleted and accepted. Coordinate deliveries with the general contractor.

1.5.4. Coordinate work with all trades and make changes to facilitate a satisfactory installation. Makeno deviations to the design intent involving extra cost to the owner, without the consultant'swritten approval.

1.6. Shop drawings/product data

1.6.1. Submit an electronic copy of detailed equipment and plumbing fixture shop drawings to engineerfor review prior to ordering. Do not order equipment or materials until engineer has reviewedshop drawings and returned shop drawings.

1.6.2. Shop drawings shall reference equipment tags, drawing number and revision/issuance date ofreferenced mechanical drawing.

1.6.3. Shop drawings shall specify the model number, relevant performance data as indicated,installation arrangement, dimensions, weight, sound levels, construction details, applicablestandards and accessories.

1.6.4. Provide original date of issue, dates of applicable revisions, project title, project address andproject number.

1.6.5. Provide name(s), wherever applicable, of contractor(s), sub-contractor(s), supplier(s),manufacturer(s), and separate detailer(s).

1.6.6. When manufacturer's standard data are submitted as shop drawings, the contractor shall alsodelete/cross out information not applicable to project.

1.7. Alternative materials and equipment

1.7.1. Contract price shall be based on materials and equipment specified. Approval by engineer ofequipment submitted by the mechanical trade as equal to that specified does not relieve themechanical trade of any responsibility. Material/products considered to satisfy the specification,but of a manufacturer other than those named, may be submitted to the consultant forconsideration not later than five (5) working days prior to closing of tender.

1.7.2. Revisions required to adapt accepted equals and alternatives shall be included in the contractprice. No increase in the contract price will be considered to accommodate equipment other thanthat specified.

1.7.3. Certain items of equipment and items of work (such as water treatment, balancing) may not havean approved equal due to the need to have a consistent type or source of maintenance. Refer tospecific clauses in this specification.

1.8. Compliance with energy by-law

1.8.1. All equipment installed on this project shall comply with the 2010 performance recommendationsof ASHRAE standard 90.1 (latest edition) as to comply with the City of Vancouver buildingby-law energy utilization requirements.

1.9. Standard of materials and workmanship

1.9.1. Workmanship shall be in accordance with well-established practice and standards accepted andrecognized by the consultant and the trade.

1.9.2. The consultant shall have the right to reject any item of work that does not conform to thecontract documents and accepted standards of performance, quietness of operation, finish andappearance.

1.9.3. Employ only tradesmen holding valid provincial trade qualification certificates. Tradesmen shallperform only work that their certificate permits.

1.9.4. Make and quality of materials used are subject to approval by the engineer. Remove unacceptablematerials and install suitable materials in their place.

1.9.5. Materials shall be new and of uniform pattern throughout, unless noted otherwise.

1.10. Core drilling and cutting

1.10.1. All work shall be co-coordinated with other trades especially that related to cutting and patchingof required openings; and locations and installation of sleeves, inserts, support, and access doors.

1.10.2. All openings through existing concrete structure shall be core drilled. Lay out requirements forreview and approval by the owner and structural engineer prior to coring.

1.10.3. Provide x-ray of all required penetrations of the floor and walls. X-ray use for locating in-floorrebar and conduit to be done after normal working hours. Take necessary precautions to protectcomputer equipment when x-raying floors. Co-ordinate with owner. Repairs to existing servicesdamaged as a result of core drilling is included in this section of the work.

1.11. Operation and maintenance manuals

1.11.1. Provide an electronic copy of manuals prepared by qualified and experienced personnel for useby the owner. Manuals form part of the contract and must be delivered to the engineer beforework will be considered complete. Each manual shall provide the following:

1.11.1.1. Layman's description of all mechanical systems including operating, maintenance andlubrication instructions,

1.11.1.2. Certification of all equipment where required by local codes and authorities,

1.11.1.3. Shop drawings and maintenance bulletins,

1.11.1.4. List addresses and telephone numbers of all equipment suppliers and contractors,

1.11.1.5. Performance details for all equipment including curves for fans and pumps with actualoperating points noted.

1.12. Owner's stock

1.12.1. Specified items of mechanical equipment may be available from the owner's stock. Prior tosubmitting the tender price, review these items to ensure their availability and usability for theproject. The tender price shall include the cost of servicing, moving in place, and installing tomake these items completely operational, or provision of new ones if required.

1.12.2. Where equipment is removed and not re-used it shall be handed over to the owner'srepresentative, or disposed of if directed by the owner.

1.13. Record drawings

1.13.1. Maintain one set of contract drawing white prints, including all supplementary and revisiondrawings on site, solely for the purpose of recording, in red, any change and / or deviation fromthe contract drawings as it occurs. Include elevations and detailed locations of buried services.

1.13.1.1. A set of CAD files may be purchased from the consultant. Allow a single per project cost of$450.00 for all mechanical project CAD files. Obtain the services of an approved CADdraftsperson to transfer all changes to amend the CAD files in the latest version of autoCAD.The consultant may be retained to draft markups into CAD at a cost not to exceed $600.00.Allow for draftsperson or consultant drafting cost.

1.13.2. Include all details from revision drawings, addenda, and change orders. Label each drawing in thelower right corner in letters of at least 12mm [1/2"] high as follows:

1.13.2.1. "As-built drawings", contractors name and date.

1.13.3. Provide one set of check prints for review by consultant.

1.13.4. Upon acceptance by the consultant, provide computer CAD files

1.13.5. Note: the contractor will be required to sign a standard Flow Consulting Group INC. / contractoragreement entitled "authorization to use CAD drawing files". The agreement restricts the use ofthe CAD files to the purpose of "as-built" only and determines the editing procedures.

1.14. Coordination with electrical division

1.14.1. Contractor shall review all equipment requiring electrical hook-up with electrical contractor andelectrical drawings prior to ordering equipment. Ensure proper electrical characteristics aredetermined for all affected and related work.

1.15. Service penetrations in rated fire separations

1.15.1. All piping, tubing, ducts, wiring, conduits, etc. passing through rated fire separations shall besmoke and fire proofed with approved materials in accordance with CAN/ULC-S115-05 andASTM E814 standards and which meet the requirements of the building code in effect.

1.15.2. Fire stop all new services that pass through existing rated separations and all existing services thatpass through new rated separations or existing separations whose rating has been upgraded.

1.15.3. Fire resistance rating of installed fire-stopping assembly shall not be less than fire resistancerating of surrounding assembly indicated on architectural drawings.

1.15.4. All smoke and fire stopping shall be installed by a qualified contractor who shall submit a lettercertifying that all work is complete and in accordance with this specification.

1.15.5. Install fire stopping and smoke seal material and components in accordance with ULCcertification and manufacturer's instructions in formed, sleeved or cored penetrations includingcomponents with exterior insulation.

1.15.6. Fire-stop materials:

1.15.6.1. Fire-stopping and smoke seal systems: asbestos-free materials and systems capable ofmaintaining an effective barrier against flame, smoke and gases in compliance withrequirements of CAN/ULC-S115-05, UL1479 and ASTM E814, and not to exceed openingsizes for which they are intended.

1.15.6.2. Fire resistance rating of installed fire-stopping assembly shall be not less than the fireresistance rating of surrounding floor and wall assembly.

1.15.6.3. Acceptable products:

1.15.6.3.1. Dow Corning FS2000 Silicone, Hilti Firestop CS2400, Tremco Fyre-sil, 3M CP25WB

1.15.7. Insulation accessories:

1.15.7.1. Flexible elastomeric and flexible closed cell insulation adhesives:

1.15.7.1.1. Armstrong 520, Therma-cel 1590, Rubatex R-373, Zipcoat 8A

1.15.7.2. Flexible elastomeric and flexible closed cell insulation finish coatings:

1.15.7.2.1. Armstrong, Bakelite120-13, Rubatex, Zipcoat

1.16. Service penetrations in non-rated separations

1.16.1. All piping, tubing, ducts, wiring, conduits, etc. passing through non-rated fire separations andnon-rated walls and floors shall be tightly fitted and sealed on both sides of the separation withsilicon sealant to prevent the passage of smoke and/or transmission of sound. Refer to "pipesleeve" clause for packing and sealing of pipe sleeves.

1.17. Painting and identification

1.17.1. Paint all exposed ducts and pipes with colors to match interior finishes or in colors as directed bythe Architect.

1.17.2. Identify piping with labels and flow arrows. Provide identification at 50 ft (15m) maximumintervals, before and after pipes passing through walls, at all sides of tees, behind access doors.

1.17.2.1. Non-insulated pipes: Brady B-500 vinyl cloth labels

1.17.2.2. Insulated pipes: Brady B-350 water-indicating label

1.17.3. Provide 3/4” (20 mm) diameter brass tags, secure to valve stems with key chain. Provide typedvalve directories.

1.17.4. Identify electric starting switches, thermostats controlling motors and equipment supplied underthis division with lamacoid plates having 1/4” (6 mm) minimum letter size.

1.18. Separate Prices

1.18.1. Include in the Tender Sum a basic price for all work specified and indicated on the drawings, butexcluding the work covered by the "Separate Prices".

1.18.2. Show, in the Tender, the "Separate Prices" for items indicated on the drawings.

2. Testing balancing & commissioning

2.1. Balancing

2.1.1. The approved balancing agencies are: Austin Metal Fabricators,Western Mechanical, K.D.Engineering.

2.1.2. Provide all required sheave, belt and impeller changes to achieve the required fan and pump flowrates.

2.1.3. Measure and balance the following (where applicable):

2.1.3.1. Supply, exhaust and return fan volumes and speeds.

2.1.3.2. Airflow at each air outlet and branch connection.

2.1.3.3. Motor amperage draw on all motors and compare with motor rating.

2.1.3.4. Water at each balance valve and terminal heating manifold.

2.1.3.5. Balance domestic water re-circulation.

2.1.4. Additional testing of the system may be requested by the consultant to spot check air and waterflow quantities. (10% of the system will be re-checked at the discretion of the consultant) at thecontractors cost.

2.1.5. Submit two (2) copies of the balancing report to the engineer within two (2) weeks aftersubstantial completion. Failure to submit the report within the specified time will result in thework being done by the owner and the costs deducted from the final payment.

2.1.6. Allow for balancing agency to check building pressure under maximum/minimum outdoor airdesign flows (where applicable)

2.1.7. Balancing shall be performed to the following accuracies:

2.1.7.1. Air terminal outlets +/- 10%

2.1.7.2. Air central equipment +/- 5%

2.1.7.3. Hydronic terminals +/- 5%

2.2. Cooperate with the balancing agency as follows:

2.2.1. Make corrections as required by the balancing agency.

2.2.2. Allow balancing agency free access to site during construction phase. Inform balancing agency ofany major changes made to systems during construction and provide a complete set of recorddrawings for their use.

2.2.3. Operate automatic control system and verify set points during balancing.

2.2.4. Provide balancing agency a complete set of mechanical drawings and specifications.

2.3. Balancing valves and dampers

2.3.1. Provide and install balancing valves, dampers and other materials requested from the balancingagency and/or necessary to properly adjust or correct the systems to design flows, withoutadditional cost to the owner.

2.3.2. Construction shall be in accordance with SMACNA Duct Standard - Fig 2-14 & 2-15.

2.3.3. Provide balancing dampers at points on low pressure supply, return and exhaust systems wherebranches are taken from larger ducts as required for proper air balancing.

2.3.4. Provide balancing dampers at each run out to a grille or diffuser as far from the air terminal aspossible.

2.3.5. On all round ductwork and on externally insulated rectangular ductwork, provide sheet metalbridges to raise quadrant type damper operators above the insulation thickness. Provide an openend bearing where bridges are used. Bridges in uninsulated round ducts shall be at least 25mmhigh.

2.3.6. Provide opposed blade balancing dampers on rectangular duct branches as indicated.

2.4. Commissioning and demonstration

2.4.1. Contractor is responsible for the performance and commissioning of all equipment supplied andre-used under the Section 22 & 23 of the National Master Specifications from the NationalResearch Council.

2.4.2. Confirm operation and review condition of all existing equipment and associated control devicesin the renovated area. Submit report noting any remedial work required.

2.4.3. At the conclusion of commissioning, demonstrate the operation of the systems to the consultantand then to the owner's operating staff.

2.4.4. At the completion of the commissioning, testing, balancing and demonstration, submit to theconsultant a letter certifying that all work specified under this contract is complete, clean andoperational in accordance with the specification and drawings.

2.5. Deficiency holdbacks and deficiency inspections

2.5.1. Work under this division which is still outstanding when substantial performance is certified willbe considered deficient and a sum equal to at least twice the estimated cost of completing thatwork will be held back.

2.5.2. It is expected that outstanding work will be completed in an expeditious manner and the entireholdback sum will be retained until the requirements for total performance of Section 22 & 23work have been met and verified.

3. Seismic restraints and vibration isolation

3.1. Scope of seismic restraints

3.1.1. Provide seismic restraints on all new and existing piping, ducts and equipment.

3.1.2. Restraints shall be in accordance with the latest edition of the Seismic Restraint ManualGuidelines for Mechanical Systems produced by SMACNA and the latest ASHRAE ApplicationsHandbook chapter on seismic restraint design and satisfy the authority having jurisdiction.

3.1.3. Submit shop drawings of all seismic restraint details prepared and sealed by a professionalengineer.

3.1.4. The seismic hazard level for each component installed under this contract shall be determined bythe professional engineer retained for seismic restraints.

3.1.5. The contractor shall obtain approval for the location of all restraint fixing points from thestructural engineer, on site, prior to installation.

3.1.6. Prior to substantial completion, this professional engineer for seismic design shall visit the site toverify seismic restraint installation and provide a letter of conformance in accordance with theapplicable Building Code.

3.1.7. Where the equipment is mounted on springs or rubber-in-shear mounts for vibration isolation itshall be the responsibility of the manufacturer of the mount to incorporate seismic restraint ofacceptable seismic hazard level. These restraints shall be multi-directional as described in theguidelines specified above. Provide steel frame bases where necessary to achieve this and alsoavoid overturning. The manufacturer shall supply certificates, verifying the design of the seismicrestraints in accordance with this section.

3.2. Air terminal - seismic restraints

3.2.1. Where air terminals are installed in mechanical grid ceiling, provide at least 12 AWG galvanizedsteel wire seismic security bridles per air terminal tied either to the building structure or to theceiling hanger wires.

3.2.2. Attach security bridges at opposite corners of each air terminal and in such manner that the airterminal cannot fall.

3.2.3. Provide all necessary brackets for attachment of security bridles to the air terminals.

3.3. Scope of vibration isolation

3.3.1. Provide vibration isolation on all motor driven equipment with motors of 1/2 HP and greaterpower output (as indicated on the motor nameplate) and on piping and ductwork, as specifiedherein. For equipment less than 1/2 HP, provide neoprene grommets at the support points.

4. Thermal and acoustic insulation

4.1. General

4.1.1. As applicable, use the latest edition of the "BC Insulation Contractors Association (BCICA)Standards Manual" as a reference standard if sufficient detail/information is not specified herein.

4.1.2. Flame spread ratings and smoke developed classifications shall be as required by the BritishColumbia Building Code 2012. Generally the flame spread rating throughout the material shallnot exceed 25 and the smoke developed classification shall not exceed 50.

4.1.3. Insulated service penetrations through fire-rated separations shall conform to the requirements ofthat section in the specifications.

4.2. Pipe insulation

4.2.1. Cold water piping: Fine fibrous glass insulation with factory applied vapour barrier jacket,moulded to conform to piping, “K” value at 75°F (24°C) maximum 0.24 btu∙in./ft2∙hr∙°F (0.035W/m∙°C) . Cover with ULC labeled thermocanvas.

4.2.2. Hot water piping: Fine fibrous glass insulation with factory applied vapour barrier jacket,moulded to conform to piping, “K” value at 75°F (24°C) maximum 0.24 btu∙in./ft2∙hr∙°F (0.035W/m∙°C) . Cover with ULC labeled thermocanvas.

4.2.3. Refer to manufacturer for insulation requirements on refrigerant piping.

4.2.4. Exposed piping: factory applied integral all-service type jacket on the pipe insulation, apply PVCjacket (minimum 0.50mm thick) FSR25/SDC50 listed.

4.2.5. Below grade heat traced grease pipe: insulation with PVC jacket (minimum 0.50mm thick)

4.2.6. Pipe insulation table:

4.3. Scope of piping insulation

4.3.1. Heating water piping, domestic hot and cold water piping, condensate piping, refrigerant piping,fittings and valves:

4.3.1.1. Insulate and vapour seal the following fittings:

4.3.1.1.1. Elbows, tees, reducers.

4.3.1.1.2. Valves, (bodies and bonnets) except check valve covers.

4.3.1.1.3. Strainers.

4.3.1.1.4. Flanges.

4.3.1.1.5. Unions.

4.4. Ductwork insulation and liner

4.4.1. Where rectangular ductwork is indicated to be acoustically insulated with flexible acoustic ductliner, liner shall be installed in accordance with instructions and figures 2-22 through 2-25,SMACNA duct standards. Duct sizes indicated are always free area inside sizes.

4.4.2. Round ducts & concealed rectangular ducts: Fine fibrous glass insulation with factory appliedaluminum foil vapour barrier, “K” value at 75°F (24°C) maximum 0.24 btu∙in./ft2∙hr∙°F (0.035W/m∙°C) .

4.4.3. Acoustic Lining: Fibrous insulation with “K” value at 75°F (24°C) maximum 0.24btu∙in./ft2∙hr∙°F (0.035 W/m∙°C) , absolute roughness of exposed surface not to exceed 0.023 in(.58mm) coated to prevent fibre erosion at air velocities up to 5000 fpm (254m/s), 1.5 lb/ft3 (24kg/m3) minimum density for ductwork and 4.7 lb/ft3 (75 kg/m3) for plenums.

4.4.4. Ensure surface and insulation is clean and dry prior to and during installation.

4.4.5. Ensure insulation is continuous through inside partitions.

4.4.6. Finish and seal insulation neatly at hangers, supports, access doors, fire dampers and otherprotrusions.

4.4.7. Cover all insulation to match architectural specifications except in ceiling spaces, crawl spaces,and mechanical shafts.

4.4.8. Provide ULC listed 2 hr fire wrap for kitchen exhaust and laundry dryer exhaust ducts.

4.4.9. Duct insulation table:

5. Piping

5.1. Steel pipe: to ASTM A53 grade B as follows:

5.1.1. To NPS 10, Schedule 40.

5.1.2. For the following systems:

5.1.2.1. Hot water heating

5.1.2.2. Relief valve vents

5.2. Copper pipe: to ASTM B88B-86, type K or L hard drawn copper tubing.

5.2.1. Type K, hard drawn: domestic hot and cold water, pumped condensate lines.

5.2.2. Type L, hard drawn: gravity drained condensate lines.

5.3. Refrigerant piping:

5.3.1. Registered in accordance with CSA B51 and shall be designed, construction and tested inaccordance with ASME B31.5 or ASME boiler and pressure vessel code, section viii, division 1

or part of a refrigeration system that are exempted from registration by clause 5.2 in referencedstandard.

5.4. Pipe joints - steel piping

5.5. NPS 2 and under: screwed fittings, except where otherwise noted, with teflon tape or pulverizedlead paste.

5.6. Pipe fittings, screwed, flanged or welded:

5.6.1. Cast iron screwed fittings: Class 125 to ANSI B16.3.

5.6.2. Unions, malleable iron ground joint type: Class 150 to ANSI B16.3.

5.7. Gate valves - NPS 2 and under, screwed:

5.7.1. Bronze body, rising stem, solid wedge disc, union or screwed bonnet.

5.7.2. Acceptable products: Class 125 [860 kPa] - Crane 428, Grinnell 3010, Jenkins 810, Kitz 24,Newman Hattersley 607, Nibco T-111, Toyo 293.

5.8. Gate valves - NPS 2 and under, soldered:

5.8.1. Bronze body, rising stem, solid wedge disc, screwed bonnet.

5.8.2. Acceptable products: Class 200 W.O.G. [1380 kPa] - Crane 1334, Grinnell 3080sj, Jenkins 813,Kitz 44, Newman Hattersley 607c, Nibco s-134, Toyo 299.

5.9. Balance fittings (screwed connections) - NPS 1¼ and under:

5.9.1. Bronze body and bronze trim, rising stem, renewable composition disc, globe type with memorystop, lockshield, male union connection, angle and straight type.

5.9.2. Acceptable products: class 100 [690 kPa] - Dahl 13000-m series, Toyo 250 or 251.

5.10. Globe valves

5.10.1. NPS 2 and under, screwed:

5.10.1.1. Bronze body, rising stem, solid wedge disc, union or screwed bonnet.

5.10.1.2. Acceptable products: class 125 [860 kPa] - Crane 428, Grinnell 3010, Jenkins 810, Kitz 24,Newman Hattersley 607, Nibco t-111, Toyo 293.

5.10.2. NPS 2 and under, soldered:

5.10.2.1. Bronze body, rising stem, solid wedge disc, screwed bonnet.

5.10.2.2. Acceptable products: class 200 w.o.g. [1380 kPa] - crane 1334, grinnell 3080sj, jenkins 813,kitz 44, newman hattersley 607c, nibco s-134, toyo 299.

5.11. Hanger spacing

5.11.1. Spacing and middle attachment (rod) diameter as specified in paragraphs below or as in tablebelow, whichever is more stringent.

5.11.1.1. Plumbing piping: most stringent requirements of BC plumbing code, provincial code, orauthority having jurisdiction.

5.11.1.2. Fire protection: to applicable fire code; toggle hangers are unacceptable.

5.11.1.3. For gas piping refer to gas code can/cga-b149.1.

5.11.1.4. Flexible joint roll groove pipe: in accordance with table below, but not less than one hangerat joints.

5.11.1.5. Within 300 mm [12"] of each horizontal elbow.

5.11.2. Maximum hanger spacing table.

5.12. Pipe sleeves

5.12.1. Provide pipe sleeves for all piping passing through walls and floors. Sleeves to be concentric withpipe.

5.12.2. Pipe sleeves for floors and interior walls shall be minimum 0.61 [24 ga] thick galvanized sheetsteel with lock seam joints.

5.12.3. Pipe sleeves shall extend 6 mm [1/4"] above floors in finished areas.

5.13. Escutcheons and plates

5.13.1. Provide on pipes passing through finished walls, partitions, floors and ceilings.

5.13.2. Plates shall be stamped steel, split type, chrome plated, or stainless steel, concealed hinge,complete with springs, suitable for external dimensions of piping/insulation. Secure to pipe orfinished surface. For all pipes passing through suspended ceilings and uninsulated piping passingthrough walls, outside diameter shall cover opening or sleeve.

5.13.3. Where pipe sleeve extends above finished floor, escutcheons or plates shall clear sleeveextension. Do not install escutcheons and plates in concealed locations.

6. Ductwork

6.1. General

6.1.1. The construction and installation of ductwork shall be in accordance with the followingreferenced SMACNA manuals and ASHRAE handbooks.

6.1.1.1. SMACNA - HVAC duct construction standards, 2005.

6.1.1.2. SMACNA - HVAC air duct leakage test manual, 2012.

6.1.1.3. ASHRAE - handbook - equipment volume.

6.1.2. The project drawings are diagrammatic and although efforts have been made to provideinformation regarding the number of offsets and transitions, not all are necessarily shown.Changes may be required in duct routings, elevation and duct shape to eliminate interference withstructure and other services. All required adjustments shall be established when coordinating andfield measuring the work prior to fabrication and must be provided as part of the contract and allassociated costs must be considered and included.

6.1.3. Duct sizes on drawings indicate clear inside dimensions. For acoustically lined or internallyinsulated ducts, maintain inside duct dimensions.

6.1.4. Proper sized openings shall be arranged for in the correct locations through all slabs and walls.Openings shall be planned to include for the installation of fire dampers at all rated fireseparations.

6.1.5. Where welded ductwork is indicated, the welding shall be continuous with everdur welding. Tackwelding is unacceptable except as specifically noted. Paint damaged areas with zinc coating afterwelding.

6.2. Galvanized steel

6.2.1. Galvanized steel shall have a 380 g/sq.m. [1-1/4 oz/sq.ft] galvanizing coat both sides to ASTMA525 G90.

6.3. Ductwork - aluminum

6.3.1. The following ductwork shall be fabricated from aluminum:

6.3.1.1. Exhaust duct work from showers/baths, to the extent noted on the drawings.

6.3.2. Low pressure aluminum ductwork shall be constructed in accordance with clause 2.2 "ductwork -500 pa [2"] static pressure".

6.3.3. For round and rectangular aluminum ductwork, use four gauges heavier than that scheduled intable 1-5 or tables 1-14, 1-15, 1-16 of the SMACNA duct standards for galvanized ductwork.

6.3.4. Aluminum shall be utility grade.

6.3.5. Support aluminum ductwork using aluminum straps, cadmium plated threaded rods, aluminumflat bar or aluminum angle hangers. Support shall be similar to that specified for galvanized ironductwork.

6.4. Ductwork pressures

6.4.1. Provide ductwork fabricated from galvanized steel for the static pressure categories listed below.

6.4.1.1. 500 pa [2" w.g.] Static pressure: all supply ductwork downstream from mixing boxes/airvalves to terminal air outlets; all return air ductwork.

6.4.1.2. 750 pa [3" w.g.] Static pressure: all supply ductwork downstream from smoke dampers(leaving duct shafts or leaving mechanical room wall) up to the upstream connections tomixing boxes/air valves.

6.4.2. Ductwork shall be constructed, reinforced, sealed and installed to withstand 1½ times theworking static pressure.

6.5. Ductwork cleaning

6.5.1. This contractor shall be responsible for and ensure that all ductwork, installed under this contractis internally clean when handed over to the owner.

6.5.2. All ductwork shall be wiped clean of all oil and other surface films with suitable solvent prior toinstallation.

6.5.3. Seal all openings at the end of each day and at such other time as site conditions dictate.

6.5.4. Other openings to be covered with 0.15 mm [6 mils] thick poly sheet taped so as to be air tight.

6.5.5. Where connecting to existing ductwork, clean re-used ductwork upstream for minimum 900 mmlength.

6.5.6. Spot checks will be made by the consultant during the cleaning process to verify that the requiredstandard is being when substantial performance is claimed, final spot checks will be made toverify that the ducts are generally if any ducts are found to be unclean, then they shall bere-cleaned.

7. Duct accessories

7.1. Balancing dampers

7.1.1. Provide and install balancing dampers, and other materials requested by the Balancing Agencyand/or necessary to properly adjust or correct the systems to design flows, without additional costto owner.

7.1.2. Construction in accordance with SMACNA duct standards - figs. 2-14 and 2-15.

7.1.3. Provide balancing dampers at points on low pressure supply, return and exhaust systems wherebranches are taken from larger duct as required for proper air balancing.

7.2. Duct connectors - vibration isolation

7.2.1. Provide flexible duct connections to provide vibration isolation at all duct and plenumconnections to fan and air handling see figure 2-19 SMACNA duct standards.

7.2.2. Minimum requirements:

7.2.2.1. Pre-assembled 75 mm [3"] minimum long flexible connection with 75 mm [3"] long 0.62mm [24 ga] galvanized steel duct connectors on each side of the flexible connection. Flexibleconnector - fiber glass fabric with elastomer coating.

7.2.3. Standard of acceptance: duro dyne "durolon", dynair "hypalon", ventfabrics "ventlon".

8. Air distribution equipment

8.1. Fans - general

8.1.1. Submit fan sound power levels with shop drawings, measured to AMCA300 and calculated toAMCA301, or other data acceptable to the consultant. Provide test data if requested. Fansexceeding design levels may be rejected.

8.1.2. Design is based on fan sound power levels, discharge only, predicted by the ASHRAE guide,1987 systems.

8.1.3. Statically and dynamically balanced, constructed in conformity with AMCA99-83.

8.1.4. Dynamically balance fans to 1.5mm/s vibration amplitude, maximum measured on bearinghousings. Provide fan shafts with critical speed at least 1.5 times operational speed.

8.1.5. Ratings: based on tests performed in accordance with AMCA 210-74, and ASHRAE 51-85. Unitsshall bear AMCA certified rating seal.

8.1.6. Refer to drawings for motor position, rotation and discharge arrangements.

9. Fire protection

9.1. Fire extinguisher

9.1.1. Furnish and install fire extinguishers in accordance with NFPA 10.

10. Controls

10.1. Related work

10.1.1. This section of the specification forms part of the contract documents and is to be read,interpreted and coordinated with all other parts.

10.2. General

10.2.1. Relocate existing control devices as indicated.

10.2.2. Where existing devices are reused, verify operation and re-calibrate as required.

10.2.3. Verify correct operation of controlled devices including pumps, control valves, etc. within thescope of the project.

10.2.4. All new control valves, actuators, sensors, thermostats, etc. are to match existing.

10.2.5. Report any existing control device which requires replacement. Replacement will be by buildingmanager or via change order, at the discretion of the owner, report of deficiencies should besubmitted prior to final commissioning so as to not delay the scheduled completion date.

10.2.6. Existing and new controls systems shall be utilized to achieve specified performance.

10.2.7. The contractor shall review all contract documents and visit the site prior to tender closing toconfirm all necessary items have been included.

10.2.8. All thermostats to be programmable type with display and read in celsius

End of section

Ducts and Equipment Insulation Thickness(in) (mm)

Acoustic lining (where indicated) 1 25Exhaust louver air plenum 1 25Exhaust air duct from outside wall to 5 ft inside 1 25Outdoor air duct from wall penetration to duct heater 1 25

Pipe sizeNPS

Rod diametermm (in.)

Maximum SpacingSteel Pipe

m (ft)Copper Pipe

m (ft)1/2 10 (3/8) 1.8 (6) 1.5 (5)3/4, 1 10 (3/8) 2.4 (8) 1.8 (6)1 1/4, 1 1/2 10 (3/8) 3.0 (10) 1.8 (6)2 10 (3/8) 3.0 (10) 3.0 (10)2 1/2, 3, 4 12 (1/2) 3.0 (10) 3.0 (10)5, 6, 8 16 (5/8) 3.0 (10) 3.0 (10)10, 12 22 (7/8) 3.0 (10) 3.0 (10)

This drawing is the property of the Designer andmay not be reproduced or used without theexpressed consent of the Designer. Allinformation shown on this drawings is for use onthis project only and shall not be usedotherwise. The Contractor is responsible forchecking and verifying all levels and dimensionsand shall report all discrepancies to theDesigner and obtain clarification prior tocommencing work. Do not scale the drawings.

flow consulting group inc.#1080 - 1075 west georgia streetvancouver, b.c. V6E 3C9v. 604 609 0500 f. 604 609 0588

C O N S U L T I N G

AutoCAD SHX Text
19/07/26
AutoCAD SHX Text
19/08/16
AutoCAD SHX Text
5
AutoCAD SHX Text
Revisions
AutoCAD SHX Text
M3
AutoCAD SHX Text
PROGRESS SET
AutoCAD SHX Text
19/09/18
AutoCAD SHX Text
STAMP/SEAL:
AutoCAD SHX Text
WALL (PROVIDE FIRE DAMPER IF REQUIRED)
AutoCAD SHX Text
814 RICHARDS STREET
AutoCAD SHX Text
Project:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
SLAB TO SLAB PARTITION OR ACOUSTIC BAFFLES
AutoCAD SHX Text
4
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
ISSUED FOR BP/TENDER
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
ISSUED FOR TENDER REV.1
AutoCAD SHX Text
1
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
ISSUED FOR TENDER
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
6
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
19/09/30
AutoCAD SHX Text
4th FLOOR FLEX
AutoCAD SHX Text
M-4
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
3
AutoCAD SHX Text
A
AutoCAD SHX Text
VANCOUVER, BC
AutoCAD SHX Text
TL
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
MIN. 6" FROM SLAB OVER
AutoCAD SHX Text
REVIEW SET
AutoCAD SHX Text
ALL DIMENSIONS SHOWN ARE INTERNAL
AutoCAD SHX Text
RTL
AutoCAD SHX Text
TRANSFER AIR OPENING
AutoCAD SHX Text
6" MINIMUM
AutoCAD SHX Text
RTL
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
19-115
AutoCAD SHX Text
ISSUED FOR BP REVIEW
AutoCAD SHX Text
Copyright C 2008 Flow Consulting Group Inc.
AutoCAD SHX Text
WORK PROJECT
AutoCAD SHX Text
%%U TRANSFER AIR DUCT DETAIL
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
2
AutoCAD SHX Text
Title
AutoCAD SHX Text
19/10/30
AutoCAD SHX Text
2019/07/26
AutoCAD SHX Text
Sheet Info.
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
19/08/23
AutoCAD SHX Text
1" ACOUSTIC INSULATION
AutoCAD SHX Text
SPECIFICATONS
AutoCAD SHX Text
SCALE:
Page 9: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation
Page 10: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation
Page 11: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation
Page 12: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation
Page 13: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation
Page 14: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation
Page 15: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

SLAB ABOVE

FRICTION FIT SOUND BOARD TO 1 SIDE OF FRAMING ABOVE. SEAL ALL JOINTS AND CUTOUTS.

STRUCTURAL BRACING OF WALL.

DIRTT WALL SYSTEM FRAME & FACE PANELS.

SC•1

SUSPENDED CEILING SYSTEM.

DETAIL • Soundproofing at PlenumSCALE: 1" = 1'-0"

1ID08

3 TENDER

2 BP ISSUE

1 Review 16.08.19

19.09.19

01.10.19

4th FLOOR

VANCOUVER, B.C.

1903

DETAILS& MILLWORK

JULY. 2019

AM

as noted

ID08

PM

FLEX WORKPROJECT

402 • 814 RICHARDS ST

6ID08

2" 2"9'-10"

SITE CONFIRM

PL•1

CONFIRM EXTENT OF OPENPHOTOCOPY COVER PRIORTO MILLWORK INSTALLATION.

DIRECTION OF GRAIN

NOTE : DETAILS ARE FOR COORDINATION PURPOSES ONLY - PROPRIETARY SEISMIC DETAILS BY DIRTT TO BE SUBMITTED WITH SHOP DRAWINGS AND SCHEDULE 'SC' PROVIDED BY CONTRACTOR.

PROJECT: TITLE: DATE:

DRAWN BY:

SCALE:

DRAWING No.: SK1

am

as noted

28 October

804 318 Homer StreetVancouver BC V6B 2V2 CanadaT 604.734.7307F 604.734.7307

D E S I G N S T U D I O I N C.

REVISIONS:RFI - 29 October 2019

Sound Proofing @ PlenumDetail814 RICHARDS ST.

COV Flex WorkVancouver, BC

Page 16: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

PROJECT: TITLE: DATE:

DRAWN BY:

SCALE:

DRAWING No.: SK2

am

1/4" = 1'-0"

October 29, 2019

804 318 Homer StreetVancouver BC V6B 2V2 CanadaT 604.734.7307F 604.734.7307

D E S I G N S T U D I O I N C.

REVISIONS:29 October 2019 - Tender RFI

814 RICHARDS ST.COV Flex Work

Vancouver, BC

ROOM 406 - WEST WALL

SURFACE MOUNT TV BY CLIENT. CONFIRM SIZE AND FINAL LOCATION. PROVIDE BLOCKING IN WALL.

4ID07

NORTH ELEVATION B

WEST ELEVATION D NORTH ELEVATION A

RCB•1APPLIANCES BY CLIENT -CONFIRM ALLMEASUREMENTS PRIOR TOFABRICATION OF MILLWORK.

WW•1

P•2

ELECTRICAL PANELS BEHIND MILLWORK CABINETS. ALL SIZES AND DETAILS TO BE CONFIRMED AT START OF CONSTRUCTION.

WRITEABLE WALLCOVER.

OMIT

REFERENCE DRAWING 3 / ID07

Page 17: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

PROJECT: TITLE: DATE:

DRAWN BY:

SCALE:

DRAWING No.: SK3

am

1/4" = 1'-0"

October 29, 2019

804 318 Homer StreetVancouver BC V6B 2V2 CanadaT 604.734.7307F 604.734.7307

D E S I G N S T U D I O I N C.

REVISIONS:29 October 2019 - Tender RFIDate

814 RICHARDS ST.COV Flex Work

Vancouver, BC

ROOM 404 - PAINT CODE REV.

ELEVATIONS • Meeting RoomScale: 1/4" = 1'-0"

4ID07

Scale: 1/4" = 1'-0"ID07

NORTH ELEVATION A EAST ELEVATION B

P•2

ELECTRICAL PANELS BEHINDMILLWORK CABINETS. ALL SIZES ANDDETAILS TO BE CONFIRMED AT STARTOF CONSTRUCTION.

REFERENCE DRAWING 4 / ID07

Page 18: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

EAST ELEVATION • Entry/Lockers, Meeting Room

OPEN

2'-1"

2'-0

"3'

-6"

3'-0

"

P•2

TR•1

TRIM. LAYOUT TO BE CONFIRMED ON SITE.

P•1

PF•2

MEETING ROOM

DIRTT WALL SYSTEM

Ø3'-6"

P•1TR•2

CIRCULAR WALL DETAILPROJECT: TITLE: DATE:

DRAWN BY:

SCALE:

DRAWING No.: SK4

am

1 1/2" = 1'-0"

October 29, 2019

804 318 Homer StreetVancouver BC V6B 2V2 CanadaT 604.734.7307F 604.734.7307

D E S I G N S T U D I O I N C.

REVISIONS:29 October 2019 - Tender RFI

814 RICHARDS ST.COV Flex Work

Vancouver, BC

REFERENCE DRAWING 6 / ID06

Page 19: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

PROJECT: TITLE: DATE:

DRAWN BY:

SCALE:

DRAWING No.: SK5

am

1/4" = 1'-0"

October 29, 2019

804 318 Homer StreetVancouver BC V6B 2V2 CanadaT 604.734.7307F 604.734.7307

D E S I G N S T U D I O I N C.

REVISIONS:29 October 2019 - Tender RFI

814 RICHARDS ST.COV Flex Work

Vancouver, BC

CIRCULAR WALL CUT OUT

P•1

2'-6"

4'-0

"

Ø2'-0"

MDF CIRCLE CUT OUTTR•2 P•1

ELECTRICAL RACEWAY AT WALL. CONFIRM HEIGHT WITH DESIGNER.

WALL PATTERN. MDF STRIPS PAINTED. LAYOUT OF PATTERN TO BE CONFIRMED ON SITE.TR•1

8'-11"

3'-8

"

Ø2'-0"Ø4'-0"

P•1 TR•2

OPEN

P•1

REFERENCE DRAWING 1 / ID06

Page 20: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

PROJECT: TITLE: DATE:

DRAWN BY:

SCALE:

DRAWING No.: SK6

am

1/4" = 1'-0"

October 29, 2019

804 318 Homer StreetVancouver BC V6B 2V2 CanadaT 604.734.7307F 604.734.7307

D E S I G N S T U D I O I N C.

REVISIONS:29 October 2019 - Tender RFI

814 RICHARDS ST.COV Flex Work

Vancouver, BC

CIRCULAR WALL DETAIL

REFERENCE DRAWING 1 / ID06

NEW WINDOWS

EXTENT OF MECHANICAL ROOM IN FRONT

2'-3

"

2'-8"

Ø2'-0"

NOTE: ALL ANGLES IN WALL PATTERN AT 45°, MITRE ALL JOINTS, PATTERN SHOWN TO BE MEASURED AND FINALIZED ON SITE BY DESIGNER.

P•1TR•2

12ID08

SOUTH ELEVATION • Open Lounge, Open Work Area B-C-DScale: 1/4" = 1'-0"

P•1

11'-7"

2'-9

"

Ø2'-0"

NOTE: ALL ANGLES IN WALL PATTERN AT 45°, MITRE ALL JOINTS, PATTERNSHOWN TO BE MEASURED AND FINALIZED ON SITE BY DESIGNER.

P•1TR•2

Page 21: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

PROJECT: TITLE: DATE:

DRAWN BY:

SCALE:

DRAWING No.: SK7

am

1/4" = 1'-0"

October 29, 2019

804 318 Homer StreetVancouver BC V6B 2V2 CanadaT 604.734.7307F 604.734.7307

D E S I G N S T U D I O I N C.

REVISIONS:29 October 2019 - Tender RFI

814 RICHARDS ST.COV Flex Work

Vancouver, BC

MEETING 404 -E & W WALL

REFERENCE DRAWING 4 / ID07

EAST ELEVATION B

P•2

SURFACE MOUNT TV BY CLIENT. CONFIRM SIZE AND FINAL LOCATION. PROVIDE BLOCKING IN WALL.

PF•3

BUTT GLASS JOINT

WEST ELEVATION D

DIRTT WALL SYSTEM

PF•2

Page 22: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

PROJECT: TITLE: DATE:

DRAWN BY:

SCALE:

DRAWING No.: SK8

am

1/4" = 1'-0"

October 29, 2019

804 318 Homer StreetVancouver BC V6B 2V2 CanadaT 604.734.7307F 604.734.7307

D E S I G N S T U D I O I N C.

REVISIONS:29 October 2019 - Tender RFI

814 RICHARDS ST.COV Flex Work

Vancouver, BC

GLASS PANEL FROSTING CONFIRMATION

REFERENCE DRAWINGS 1 / ID07 AND 9 / ID06

WEST ELEVATION B

DIRTT WALL SYSTEM

WELLNESS ROOM

OPEN

PF•6

APPLIANCES BY CLIENT -CONFIRM ALLMEASUREMENTS PRIOR TOFABRICATION OF MILLWORK.

ENTIRE GLASS PANELGF•1

5ID09

NORTH ELEVATION • Photocopy EAST ELEVATION • Photocopy, Wellness, Open Work Area DScale: 1/4" = 1'-0"

9ID06

PF•6

WELLNESS ROOM

ACCOUSTIC BAFFLE.

DIRTT WALL SYSTEM

5ID08 ENTIRE GLASS PANEL

GF•1

Page 23: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation
Page 24: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

CODE IMAGE DESCRIPTION SUPPLIER EXTENTGENERAL NOTES: ALL(AREA’S) MILLWORK TO BE AWMAC STANDARDS FOR CUSTOM GRADE

TR•1 Product: WALL DECOR Supplier: n/aSpecies: MDF Contact:

Thickness: 1” x width as noted on drawingsFinish: Paint Phone: Notes: Refer to elevations/detail drawings

TR•2 Product: WALL DECOR Supplier: n/aSpecies: MDF Contact:

Thickness: 1 1/2” x diameter as noted on drawingsFinish: Paint Phone: Notes: Refer to elevations/detail drawings

BlueFish Studio 814 RICHARDS ST 804-318 Homer Street Project: 1903Vancouver. BC Issued: TENDER604-734-7307 Date: Sep 23, 2019

Revision #:Revision Date:

ARCHITECTURAL WOODWORK - TRIM page � of � SECTION 06 46 00 1 1

Page 25: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

CODE IMAGE DESCRIPTION SUPPLIER EXTENTL•1 Product: LED 1’X4’ Lighting Supplier: CDM2 Throughout

MANUFACTURER: FLUXWERX Contact: Daniel PoirierModel: Rails 1X4 (RA1-14) Phone: 604-340-6018

Dimensions: 12” X 48”Colour Temperature: 3500K

Installation: Suspended T-Bar Ceiling SystemQTY: 61 (TBC)

Notes: Contractor to confirm quantity.

L•2 Product: Pendant Fixture Supplier: Inform Contract Open LoungeMANUFACTURER: BuzziShade Contact: Robyn York 411 & 415

Model: BuzziShade Pendant LED Globe Phone: 604-535-0646Dimensions: 24.41” X 23.23”

Finish: FeltInstallation: Suspended Ceiling

QTY: 2Notes: Confirm mounting height on site with designer

L•3 Product: Suspended Fixture Supplier: CDM2 KitchenMANUFACTURER: EUREKA Contact: Daniel Poirier 409

Model: LILY Phone: 604-340-6018Code: 4040

Finish: PGEColour Temperature: 3500K

Dimensions: 60” X 7.85”Voltage: 120 Volt

QTY: 5Notes: Confirm mounting height on site with

designer

CODE

BlueFish Studio 814 RICHARDS ST 804-318 Homer Street Project: 1903Vancouver. BC Issued: TENDER604-734-7307 Date: Sep 23, 2019

Revision #:Revision Date:

LIGHTING page � of � SECTION 26 50 00 1 4

Page 26: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

L•4 Product: Suspended Linear Fixture Supplier: Symmetry Meeting RoomManufacturer: Light Art Contact: Stephen Epstein 404

Code: 2-STATIC-96-12-ZN-WO-CR-16-STD ID-935-NA-HE-P01-SC-OS-WP-WH-120

Phone: 778-926-5391

Mount: Continuous Row PendantLED CRI/CTT: 90 CRI / 3500K

Finish: Zinc Acoustic FeltDriver: Philips 0-10v

Dimensions: 4’ FixtureCircuiting: Single Circuit

QTY: 3Notes: Confirm mounting height on site with

designer

L•5a Product: Suspended Light Fixture Supplier: CDM2 Open MeetingMANUFACTURER: CREE Lighting Contact: Daniel Poirier

Model: Stylus Linear Series Phone: 604-340-6018Code: ST3-SD-2-H-35K-Blank-L-10V-04-A-WH

Finish: WhiteColour Temperature: 3500K

Dimensions: 3” X 24”Voltage: 120 Volt

Cable Length: 04-4’QTY: 3

Notes: Confirm mounting height on site with designer

IMAGE DESCRIPTION SUPPLIER EXTENTCODE

BlueFish Studio 814 RICHARDS ST 804-318 Homer Street Project: 1903Vancouver. BC Issued: TENDER604-734-7307 Date: Sep 23, 2019 Revision #: Revision Date:

LIGHTING page � of � SECTION 26 50 00 2 4

Page 27: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

L•5b Product: Suspended Light Fixture Supplier: CDM2MANUFACTURER: CREE Lighting Contact: Daniel Poirier Informal Meeting

Space AModel: Stylus Linear Series Phone: 604-340-6018Code: ST3-SD-2-H-35K-Blank-L-10V-04-A-WH

Finish: WhiteColour Temperature: 3500K

Dimensions: 3” X 48”Voltage: 120 Volt

Cable Length: 04-4’QTY: 5

Notes: Confirm mounting height on site with designer

L•6 Product: Suspended Light Fixture Supplier: CDM2 Informal Meeting Space B

MANUFACTURER: EUREKA Contact: Daniel PoirierModel: Verner 4273-14 Phone: 604-340-6018Code: 4273-14-LED-30-120V-DV-C-36-BLKE-

BLKE-WHFinish: Black

Colour Temperature: 3500KDimensions: 13.55” X 14.55”

Voltage: 120 VoltCable Length: 60”

QTY: 1Notes: Confirm mounting height on site with

designer

IMAGE DESCRIPTION SUPPLIER EXTENTCODE

BlueFish Studio 814 RICHARDS ST 804-318 Homer Street Project: 1903Vancouver. BC Issued: TENDER604-734-7307 Date: Sep 23, 2019 Revision #: Revision Date:

LIGHTING page � of � SECTION 26 50 00 3 4

Page 28: INVITATION TO TENDER (“ITT”) No. PS20191185 CONTRACTOR FOR ... - Supply Management · 2019. 11. 1. · finance, risk and supply chain management page 1 november 1, 2019 . invitation

L•7 Product: not used Supplier: MANUFACTURER: Contact:

Model: Phone: Code:

Finish: Colour Temperature:

Dimensions: Voltage:

QTY:Notes:

L•8 Product: Surface LED Fixture Supplier: CDM2 Mechanical RoomMANUFACTURER: CREE Lighting Contact: Daniel Poirier 405

Model: LS4 Phone: 604-340-6018Code: LS4-25L-40K-BLANK-10V

Finish: N/AColour Temperature: 4000K

Dimensions: 48.0” X 2.5” X 3.0”Voltage: 120 Volt

QTY: 1Notes:

IMAGE DESCRIPTION SUPPLIER EXTENTCODE

BlueFish Studio 814 RICHARDS ST 804-318 Homer Street Project: 1903Vancouver. BC Issued: TENDER604-734-7307 Date: Sep 23, 2019

Revision #:Revision Date:

LIGHTING page � of � SECTION 26 50 00 4 4