Upload
lydia-hubbard
View
247
Download
0
Embed Size (px)
Citation preview
Introduction to Temperature Sensors
ISAT 300 Instrumentation and Measurement
02/17/1999
CoolBath
HotBath
Temperature Measurement Devices
Electrical Effects Thermocouples Thermistors Resistance Temperature Detectors (RTD)
Mechanical Effects Liquid-in-glass thermometers
Radiation (non-contact) Pyrometers
Introduction
Somehow, we need to translate the temperature of an object to a voltage that a data acquisition system can read.
A look at transducers that translate a change in temperature to a change in voltage or resistance.
LanguageRange of Operation
Lowest to highest temperatureActive vs. Passive
Require external power source?Intrusive vs. Non-intrusive
Will this affect the system?Linearity
Is the conversion from voltage to temperature a line or a more complicated function?
Sensitivity
Temperature TransducersThermocouples
Voltage Device, passive, non-linear -270 to 1372oC for type Ktype K
Thermistors Resistive Device, active, non-linear -100 to 300oC
RTDs (Resistance Temperature Detectors) Resistive Device, active, linear Large Range: -200 to +850oC for
Platinum Low sensitivity: 0.39 % per oC
ThermocouplesTwo disimilar metals are joined togetherChange in temperature at junction
generates voltageSmaller size compared to thermistorsFast response time (time constant as small
as 1 ms)Ease of fabrication, long term stabilityLow sensitivity, small output voltageNeed reference temperature
Thermocouples
Passive Device Voltage is developed as the function of the
the temperature of the junctionSeebeck Effect
A thermoelectric phenomenon The sum of two voltage effects, namely
Peltier effect and Thompson effectUse in Computer-Based Instrumentation
Thermocouples - Background
Kirchhoff’s Voltage Law Sum of all voltages
in a loop = 0.
+_??V
+
_
2V
+_
_+
-3V
5V
Kirchhoff’s Current Law Sum of all currents
entering a node is 0.
5 mA
3 mA
?? mA
How Does Thermocouple Work?Seebeck Effect
An electromotive force (EMF) exists in a loop made of two dissimilar metals when the two junctions are different temperatures.
T1 T2
A
B
T1 T2
A
B
+
_+
_
AB BA
Peltier EMF Voltage at the junction of two dissimilar
metals Denoted as AB, BA
How Does Thermocouple Work?
Thompson EMF Voltage in a wire caused by a temperature
difference between the ends. Denoted as A, B
T2
A
B
+ _
+ _
T1
A
B
How Does Thermocouple Work?
The Ice Point - A Reference Junction
V V V V VT T T T DVM1 3 3 2 0
V V VT T DVM1 2 0
V V VDVM T T 1 2
B
T1
AT3
DVM
T3
Copper
A
+
+
+
T2ICE
Using Thermocouples
Removing the Ice Point DVM shows the voltage due to the
difference between T1 and T2 Use the same equation as before!!
T2Chromel
Alumel
T1 DVM
T2
Copper V V VDVM T T 1 2
Conversion Process in General Measure the Temperature, T2 Measure the voltage using the DVM, VDVM Convert the temperature of T2 to a voltage (table),
VT2 Add voltage from DVM to the voltage for T2, VDVM
+ VT2 Convert the voltage sum to T1 (use a table)
T2Chromel
Alumel
T1
T2
CopperDVM
Using Thermocouples
Example: A type R thermocouple system with an ice reference has an output of 9.1 mV. What is the temperature of the sensing junction?
From OMEGA Type R Thermocouple Reference Table, ttp://www.omega.com/techref/tctables/rc-2.html9.090 mV corresponds to 891oC and 9.103 mV corresponds to 892oC.
Linear interpolation gives a temperature 891.8oC for 9.1 mV.
Thermocouple Reference Tablewww.omega.com/techref/tctables/rc-2.html