Introduction to ABB RTU 560
©C
opyr
ight
yea
r AB
B -
2-
History of ABB RTUs
ABB RTU Families
1970 1980 1990 2000
Indactic 21
RTU 232
RTU 560
74 90
88 99
RTU 21093
98
99
I 21-Support in HW
Only ZG20 support needed
FM 10b / ZM 20 / others Support in HW
NI23 RTU 20087
RTU 51095 98
*
* = marketing stopped
RTU 21198
*
©C
opyr
ight
yea
r AB
B -
3-
History of ABB RTUs
RTU200 >>> RTU232 >>> RTU560 Evolution
23ZG20
one I/O board family over all generations
23ZG21(32 bit CPU)
new flexible & scalable platform
©C
opyr
ight
yea
r AB
B -
4-
Highlights of RTU560Support of standard
communication protocols Scalability for different applications
High performancemultiprocessor architecture
Diagnosis withWeb-Server technology
Redundancy
State-of-the-art, Windows® basedengineering tool
Open data exchangeconcept
PLC FunctionsAccording to IEC 61131-3
Reverse Engineeringof Configuration Data
Data archives
Integration into theIT environment
©C
opyr
ight
yea
r AB
B -
5-
RTU560 Systems
Solutions:
� RTU560A
� RTU560C
� RTU560E
©C
opyr
ight
yea
r AB
B -
6-
RTU560A
� Sophisticated RTU solution for huge and medium applications
� High performance data processing and communication features
� Suitable for high availability and redundancy requirements
� Always including a communication subrack
©C
opyr
ight
yea
r AB
B -
7-
NCC(s)1...8 Serial interfaces1...2 Ethernet interfaces
560PSU01
560ETH01
560SLI01
560PCA01
560RTC0
1
560BCU0
1560PS
U01560ET
H01560SLI01
560CSR01
System BusDistance < 2m
560PSU01
560ETH01
560SLI01
560PCA01
560RTC0
1
560BCU0
1560PS
U01560ETH
01560SLI01
560CSR01 (opt.)
1... 32 Subdevice lines
Peripheral Bus
23BE21
560PSU01
23BE21
23BE21
23BE21
23BE21
23BE21
23BE21
23TP21/23ET23
23BE21
560PSU01
23BE21
23BE21
23BE21
23BE21
23BE21
23BE21
1..7 23TP21/23ET23
23TP21/23ET23
23BE21
560PSU01
23BE21
23BE21
23BE21
23BE21
23BE21
23BE21
1..4 Segments
1..7
Peripheral Bus
23BE21
560PSU01
23BE21
23BE21
23BE21
23BE21
23BE21
23BE21
23TP21/23ET23
RTU560A Configuration
©C
opyr
ight
yea
r AB
B -
8-
RTU560C
� Compact and economic RTU solution for huge and medium applications
� Suitable for standard communication requirements
� No redundancy requirements
� No communication subrack needed
©C
opyr
ight
yea
r AB
B -
9-
1... 5 Subdevice lines
1...6 serial lines
NCC
23BE21
560PSU01
23BE21
23BE21
23BE21
23BE21
23BE21
23BE21
23TP21/23ET23
560SLI01
560SLI01
RTU560C Configuration
Peripheral Bus
23BE21
560PSU01
23BE21
23BE21
23BE21
23BE21
23BE21
23BE21
23TP21/23ET23
23BE21
560PSU01
23BE21
23BE21
23BE21
23BE21
23BE21
23BE21
1..6 23TP21/23ET23
23TP21/23ET23
23BE21
560PSU01
23BE21
23BE21
23BE21
23BE21
23BE21
23BE21
1..4 Segments
1..6
Peripheral Bus
23BE21
560PSU01
23BE21
23BE21
23BE21
23BE21
23BE21
23BE21
23TP21/23ET23
©C
opyr
ight
yea
r AB
B -
10-
RTU560E
� function compatible with RTU560A,C
� up to 4 Multi I/O modules / housing
� Multi I/O module, up to 220 VDC, 16 binary inputs, 8 binary outputs, 4 analog inputs
� optional modems� V.23� dial up analog
� optional Ethernet interface (10BaseT; RJ45)
� power supply� 24 ... 220 VDC power supply � 110...230 VAC power supply
optional battery (2 hours)
©C
opyr
ight
yea
r AB
B -
11-
RTU560E
� RTU560E� Applications:
� Small distribution substations
� Distributed architectures with decentralized I/O units
� Benefits� Low cost solution for small applications
� Easy and fast assembling, mounting and commissioning
� Same functional scope as RTU560A/C
©C
opyr
ight
yea
r AB
B -
12-
General Modules RTU560EHousing 560HOS80
Communication Unit 560CMU80
Multi I/O 560MIO80
Modem Unit 560MOD8x
©C
opyr
ight
yea
r AB
B -
13-
Protocols for host communication
� Support of standard protocols� IEC 60870-5-101� IEC 60870-5-104� DNP 3.0, also based on TCP/IP� Modbus� Indactic 23 / Indactic 33� RP570/571
� 3rd parties/country specific protocols� Telegyr TG800� Estel (South Africa)� CDT, CDC8890 and µ4F (China)� WISP+ (Malaysia and Great Britain)
©C
opyr
ight
yea
r AB
B -
14-
� Standard protocols:� IEC 60870-5-101
� IEC 60870-5-103
� DNP 3.0
� Modbus RTU and ASCII
� Counter Interface IEC 61107
� Counter Interface IEC 60870-5-102
� ABB specific protocols� RP570 / RP571
� SPA-bus
Subdevice Interfaces
©C
opyr
ight
yea
r AB
B -
15-
RTU560 System Architecture
RTU560 System bus
CPU CPU CPUCPU
CPU CPU CPUCPU
Different network control systems
I/O modules
I/O modules
I/O modules
I/O modules
IED
IED Sub-RTU
Sub-RTU
©C
opyr
ight
yea
r AB
B -
16-
Communication
� Up to 8 serial communication lines for host communication
� Up to 60 communication lines to subordinated devices, (sub-RTUs, IEDs, etc.)
� Support of different communication concepts� Local or wide area networks
� Serial links with RS232-C interfaces� Direct link
� Voice-frequency communication
� Radio link
� Satellite communication
� PLC links