12
INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAI INDIA NO FINANCIAL INTEREST

INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

Embed Size (px)

Citation preview

Page 1: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL

Dr. KUMAR J DOCTOR

DOCTOR EYE INSTITUTE MUMBAI INDIA

NO FINANCIAL INTEREST

Page 2: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

On line pachymetry

Is a high resolution non contact method which enables the corneal thickness changes to be measured intra operatively during all steps of the surgery.

It adds new safety dimensions to Lasik.

Page 3: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

Importance OF OCP

Is in patients with

Thin corneas

High refractive errors

Who need enhancement and retreatments

Fear of keratectasia

Page 4: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

Online OCP Optical Coherence Pachymeter

AMARIS SCHWIND LASER

mirror

beamsplitter

light source

detector

eye

s(t)

OCP-signal from Michelson Interferometer

Page 5: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

The direct integration of Online Pachymetry into

the AMARISIt comes with fiberglass

coupling

and through Automated

measurements of changes in

Corneal thickness, allows

continuous and real time values

with 10 measurements per

second, without having

to interrupt the

treatment.

LASIKLASIK--CutCutPre-cut

540 µm394 µm

0 µm

t

Post-cut

The reproducibility of current System is 1 to 2 microns.

Page 6: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

OCP

RECORDING

DURING

SURGERY

Page 7: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

Purpose:

To investigate Intraoperative Optical Coherence Pachymetry during various steps of Laser in Situ Keratomileusis (LASIK)

Page 8: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

Method:

With the Integrated Online Pachymetry 50 patients with Myopia were studied.

LASIK was performed with 90 micron head for all eyes using Carriazo Pendular Microkeratome.

Online pachymetry measures the corneal thickness before and after lifting the flap AUTOMATICALLY .

This reading was subtracted from the one before flap creation to get accurate flap thickness.

Post-op 1 month OCT for Flap thickness was done for every eye.

Page 9: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

Observation

Mean spherical equivalent refraction was – 5.0 D, +/- 4.0 D .

Mean stromal depth of 100 +/- 18 µ was ablated.

Mean flap thickness was 90 µ, +/-9 µ.

Residual corneal stromal bed of more than 300 microns was preserved in all cases.

The immediate post op showed swelling of the cornea.

Page 10: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

ResultsThe flap thickness measured by OCP

and OCT post I month.

Mean Thickness of Flap by OCP Mean Thickness of flap by OCT85

86

87

88

89

90

91

92

93

90 90

Th

ickn

ess

in M

icro

ns

Page 11: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

Discussion

Efficiency and safety of lasik procedure has increased with the integrated OCP.

Further horizons are widened for treatment of thin corneas , to prevent keratectasia

This has proved extremely beneficial in cases that require retreatment or enhancement .

OCP is a great link with the Excimer Laser

Page 12: INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST

Conclusion:

The real time online pachymetry being non contact takes measurement through all steps of the surgery .

This is an important safety feature for monitoring flap thickness with each cut and to check residual stromal thickness.

Prevents itrogenic corneal ectasia in patient with thin corneas.