34
INTERNAL SQUARE CORNER - DIRECT FIXED SELECTED PLASTER FINISH ADDITIONAL FRAMING IS REQUIRED IN ALL INTERNAL CORNERS (I.E. DOUBLE STUDS) NOVEMBER 2010 APPROVED PROPRIETARY BREATHER TYPE SARKING CONTINUOUS AROUND CORNER FIXED OVER FRAMING BY BUILDER INSULCLAD PRE-MESHED BOARD OR EPS SHEET

INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

INTERNAL SQUARE CORNER - DIRECT FIXED

SELECTED PLASTER FINISH

ADDITIONAL FRAMING ISREQUIRED IN ALL INTERNALCORNERS (I.E. DOUBLESTUDS)

NOVEMBER 2010

APPROVED PROPRIETARYBREATHER TYPE SARKINGCONTINUOUS AROUNDCORNER FIXED OVERFRAMING BY BUILDER

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

Page 2: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

EXTERNAL SQUARE CORNER - DIRECT FIXED

SELECTED PLASTER FINISH

20 x 20 PVC CORNER BEND

APPROVED PROPRIETARYBREATHER TYPE SARKINGCONTINUOUS AROUNDCORNER FIXED OVERFRAMING BY BUILDER

NOVEMBER 2010

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

Page 3: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

50

CONCRETE SLAB FLOOR - DIRECT FIXED

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

PVC L BEND

100mm TO PAVED GROUND175mm TO UNPAVED GROUND

D.P.C

NOTE:TERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE

Page 4: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

50

TIMBER FLOOR FOUNDATION - DIRECT FIXED

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

PVC L BEND100mm TO PAVEDGROUND175mm TO UNPAVEDGROUND

NOTE:TERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE

SELECTED FLOORING

Page 5: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

TIMBER FLOOR FOUNDATION - DIRECT FIXED

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

PVC L BEND

NOTE:TERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE

SELECTEDFLOORING

Page 6: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

50mm m

in

REBATED CONCRETE SLAB FLOOR - DIRECT FIXED

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

D.P.C

NOTE:TERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE

REBATE IN THE SLAB MUST BECOMPLETELY WATERPROOFED WITHA PROPRIETARY TANKING MEMBRANEAS SPECIFIED BY THE DESIGNER.INSTALLED BY OTHERS.

6mm MS SEALANT JOINT AGAINSTPEF BACKING ROD

PVC L BEND

Page 7: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

35mm

35mm

ROOF / WALL JUNCTION - DIRECT FIXED

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

PVC L BEND

min.

FLASHING MUST EXTEND AMINIMUM OF 75mm BEHINDCLADDING AND MUST BETAPED ONTO THE SARKINGWITH WATERPROOFMEMBRANE TAPE BY BUILDER

SELECTED ROOFING WITHSTOP ENDS

Page 8: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

10min

MS SEALANT OVER COMPRESSEDFOAM BACKING ROD

SELECTED PIPE

SARKING TAPED ONTO PIPE USINGWATERPROOF MEMBRANE BYOTHERS. WRAP FLASHING TAPE25mm AROUND PIPE AND 100mmONTO SARKING

TIMBER PACKING INSTALLED BYBUILDER

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

PIPE PENETRATION - DIRECT FIXEDNOVEMBER 2010

COMMENT: WHERE POSSIBLEPIPE PENETRATIONS SHOULD BEINSTALLED SLOPING DOWN

Page 9: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

SOFFIT DETAIL - DIRECT FIXEDNOVEMBER 2010

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

INSULCLAD PRE-MESHEDBOARD OR EPS SHEET

NOGGING AS REQUIRED FORINSULCLAD BOARD FIXINGINSTALLED BY THE BUILDER

SOFFIT LINING

Page 10: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

VERTICAL CONTROL JOINT - DIRECT FIXED

SELECTED PLASTER FINISH

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

PVC L BEND

ADDITIONAL FRAMING WILLBE REQUIRED WITH 35mm STUDS

PEF BACKING ROD AND SEALANTBETWEEN 8 - 10mm GAP

100mm WIDE FLASHINGBEHIND CONTROL JOINT

Page 11: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

FIXING BLOCK - DIRECT FIXEDNOVEMBER 2010

H3 TREATED TIMBER BLOCKING CUTTO SUIT POLY THICKNESS ANDAPPLIED OVER SARKING BY THEBUILDER

SELECTED PLASTER FINISH

APPROVED BREATHER TYPESARKING INSTALLED BY BUILDER

WATERPROOF MEMBRANE PATCHMUST COVER ALL SIDES OFFIXING BLOCK BY 50mm

Page 12: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

METER BOX - HEAD AND JAMB - DIRECT FIXED

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

PVC L BEND

NOTE:METER BOXES MUST BE INSTALLED IN SHELTERED LOCATIONS

EXTRA NOGGINGAS REQUIRED

5mm BEAD OF MS SEALANT BACKEDBY A COMPRESSED FOAM BACKING ROD

METER BOX TAPED ONTO SARKINGUSING WATERPROOF MEMBRANE BYBUILDER - TAPE TO EXTEND MIN 100mmONTO SARKING AND MIN. 50mm ONTO BOX

METER BOX

Page 13: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

10mm

WINDOW H

EAD - D

IRECT FIXED

APPROVED PROPRIETARY BREATHER

TYPE SARKING FOLDED IN

TO

OPENING, IN

STALLED BY BUILDER

NOVEMBER 2010

INSULCLAD PRE-M

ESHED BOARD

OR EPS SHEET

DRIP EDGE FORMED IN

PLASTER

PVC L BEND

SEALANT JOINT

AS 2047 COMPLIANT

WINDOW JOINERY

REVEAL

POLYURETHANE FOAM

AIRSEAL O

VER PEF ROD

INTERNAL LINING

FLASHING TAPE TO CORNERS

WINDOW SILL - D

IRECT FIXED

NOVEMBER 2010

POLYURETHANE FOAM

AIRSEAL O

VER PEF ROD

10mm

APPROVED PROPRIETARY BREATHER

TYPE SARKING FOLDED IN

TO

OPENING, IN

STALLED BY BUILDER

AS 2047 COMPLIANT

WINDOW JOINERY

REVEAL

SILL FLASHING TO DRAIN W

ATER

FROM SILL AND JAMB

FLASHING TAPE ALONG SILL,

100mm UP JAMB AND 50mm

ONTO FACE O

F SARKING

EPS BOARD CUT O

N 15°

SLOPE AT SILL

INSULCLAD PLASTER SYSTEM

10mm

WINDOW JAMB - D

IRECT FIXED

NOVEMBER 2010

APPROVED PROPRIETARY BREATHER

TYPE SARKING FOLDED IN

TO

OPENING, IN

STALLED BY BUILDER

INSULCLAD PRE-M

ESHED BOARD

OR EPS SHEET

PVC L BEND

SEALANT JOINT

FLASHING TAPE TO CORNERS

AS 2047 COMPLIANT

WINDOW JOINERY

REVEAL

POLYURETHANE FOAM

AIRSEAL O

VER PEF ROD

INTERNAL LINING

INSULCLAD PLASTER SYSTEM

Page 14: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

INTERNAL SQUARE CORNER - CAVITY

SELECTED PLASTER FINISH

ADDITIONAL FRAMING ISREQUIRED IN ALL INTERNALCORNERS (I.E. DOUBLESTUDS)

20mm CAVITY

NOVEMBER 2010

APPROVED PROPRIETARYBREATHER TYPE SARKINGCONTINUOUS AROUNDCORNER FIXED OVERFRAMING BY BUILDER

VERTICAL 50mm x 20mm CAVITYBATTENS

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

Page 15: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

EXTERNAL SQUARE CORNER - CAVITY

SELECTED PLASTER FINISH

20 x 20 PVC CORNER BEND

APPROVED PROPRIETARYBREATHER TYPE SARKINGCONTINUOUS AROUNDCORNER FIXED OVERFRAMING BY BUILDER

NOVEMBER 2010

20mm CAVITY

VERTICAL 50mm x 20mm CAVITYBATTENS

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

Page 16: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

50

15

CONCRETE SLAB FLOOR - CAVITY

CAVITY PACKERS 100mm LONGAT FIXINGS

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

20mm CAVITY

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

PVC L BEND

VENT STRIP100mm TO PAVED GROUND175mm TO UNPAVED GROUND

D.P.C

NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRETERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE

Page 17: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

50

15

TIMBER FLOOR FOUNDATION - CAVITY

CAVITY PACKERS 100mm LONGAT FIXINGS

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

20mm CAVITY

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

PVC L BEND

VENT STRIP

100mm TO PAVEDGROUND175mm TO UNPAVEDGROUND

NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRETERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE

SELECTED FLOORING

Page 18: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

PIER FOUNDATION - CAVITY

CAVITY PACKERS 100mm LONGAT FIXINGS

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

20mm CAVITY

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

PVC L BEND

VENT STRIP

NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRETERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE

SELECTEDFLOORING

Page 19: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

50mm m

in

REBATED CONCRETE SLAB FLOOR - CAVITY

CAVITY PACKERS 100mm LONG AT FIXINGS

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

20mm CAVITY

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

D.P.C

NOTE:OPENINGS IN VENTS TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRETERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE

TYPICAL VENT DETAIL

PROPRIETRY SUBFLOOR VENTS.VENTS TO SIT LEVEL WITH BOTTOMOF REBATE AND TO REMAINUNSEALED ON BOTTOM EDGE,

REBATE IN THE SLAB MUST BECOMPLETELY WATERPROOFED WITHA PROPRIETARY TANKING MEMBRANEAS SPECIFIED BY THE DESIGNER.INSTALLED BY OTHERS.

100mm TO PAVEDGROUND

175mm TO UNPAVEDGROUND

Page 20: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

50mm m

in

REBATED CONCRETE SLAB FLOOR - CAVITY(IN BETWEEN VENTS)

CAVITY PACKERS 100mm LONG AT FIXINGS

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

20mm CAVITY

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

D.P.C

NOTE:TERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE

REBATE IN THE SLAB MUST BECOMPLETELY WATERPROOFED WITHA PROPRIETARY TANKING MEMBRANEAS SPECIFIED BY THE DESIGNER.INSTALLED BY OTHERS.

6mm MS SEALANT JOINT AGAINSTPEF BACKING ROD

PVC L BEND

PROPREITARY VENTS TO BEINSTALLED AS PER DETAIL

100mm TO PAVEDGROUND

175mm TO UNPAVEDGROUND

Page 21: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

35mm m

in

100mm m

in

15

ENCLOSED BALCONY - CAVITY

CAVITY PACKERS 100mm LONG AT FIXINGS

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

20mm CAVITY

INSULCLAD PRE-MESHEDBOARD OR EPS SHEET

SELECTED PLASTER FINISH

NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRETERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE

BACKING FOR MEMBRANEUPSTAND

SELECTED FLOORING

SEALANT

NOTE !DESIGN OF THE FLASHINGS AROUNDCANTILEVERED FLOOR JOISTS IS THERESPONSIBILITY OF THE DESIGNER ANDINSTALLATION IS THE RESPONSIBILITY OFTHE BUILDING CONTRACTOR

VENT STRIP TILES

WATER PROOF MEMBRANE ASSPECIFIED BY DESIGNER ANDINSTALLED BY AN INDEPENDANTLICENSED WATERPROOFINGCONTRACTOR

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

50mm x 20mm CAVITY BATTEN

SOFFIT LINING

INSULCLAD PRE-MESHEDBOARD OR EPS SHEET

CANTILIVERED H3 JOISTS

SELECTED FLOORING

Page 22: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

70 70mm m

in

15

35mm

PARAPET METAL CAPPING - CAVITYNOVEMBER 2010

NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRE

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

SELECTED PLASTER FINISH

20mm CAVITY

NOTE: CONTINUOUS METALPARAPET (CAP MUST BE SIDE FIXEDBELOW PEF ROD) AS SUPPLIED ANDFITTED BY OTHERS

COMPRESSED PEF BACKING RODINSTALLED BY OTHERS

VENT STRIP

min

H3 TIMBER WEDGE

UNDERLAY TO PROVIDESEPARATION OF METALCAP AND TIMBER

CAVITY PACKERS 100mmLONG AT FIXINGS

NOTE; IF ROOF IS BEINGUSED AS AN INTERNALGUTTER, THE CLADDINGMUST BE MIN. 100mm ABOVEMEMBRANE SURFACE

WATER PROOFING EXTENDMIN. 150mm UP ANYVERTICAL SURFACE

5° min slope

INSULCLAD PRE-MESHEDBOARD OR EPS SHEET

Page 23: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

35mm 15

BALCONY CAPPING - CAVITYNOVEMBER 2010

NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRE

min

CAVITY PACKERS 100mm LONG

WATERPROOFING MEMBRANEMUST EXTEND A MINIMUM OF150mm UP ANY VERTICALSURFACE

INSULCLAD BOARD MUSTBE CAPPED 35mm ABOVEFINISHED BALCONY LEVEL

15° min slope

3mm THICK EPDMGASKET BETWEENPLASTER & BRACKET

TIMBER BLOCK MUST BE COVEREDWITH A WATERPROOF MEMBRANEPATCH COVERING INSULCLADBOARD BY A MIN. OF 50mm

DRESSED H3 FIXING BLOCKS MUST BEPLACED AT THE FRONT OR BACK OFWALL NOT THE TOP, BY BUILDER

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

SELECTED PLASTER FINISH

20mm CAVITY

PVC L BEND

VENT STRIP

TWO LAYERS OF REINFORCINGFIBREGLASS MESH OVERSURFACE OF EIFS TAPEMEMBRANE EXTEND DOWN EACHSIDE MIN. DISTANCE OF 50mm

Page 24: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

6mm O/HANG

30mm

FLUSH EAVES - CAVITYNOVEMBER 2010

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

SELECTED PLASTER FINISH

20mm CAVITY

PEF ROD

BEAD OF MS SEALANT IF NECESSARY

SOLID BLOCKING TO CLOSEOFF CAVITY AT TOP OF WALL

CAVITY BATTEN

INSULCLAD PRE-MESHEDBOARD OR EPS SHEET

MIN

SELECTED ROOFING

Page 25: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

15

35mm

35mm

ROOF / WALL JUNCTION - CAVITY

CAVITY PACKERS 100mm LONG AT FIXINGS

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

20mm CAVITY

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

PVC L BEND

VENT STRIP

NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRE

min.

FLASHING MUST EXTEND AMINIMUM OF 75mm BEHINDCLADDING AND MUST BETAPED ONTO THE SARKINGWITH WATERPROOFMEMBRANE TAPE BY BUILDER

SELECTED ROOFING WITHSTOP ENDS

Page 26: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

10min

INSULCLAD PRE-MESHEDBOARD OR EPS SHEET

MS SEALANT OVER COMPRESSEDFOAM BACKING ROD

SELECTED PIPE

SARKING TAPED ONTO PIPE USINGWATERPROOF MEMBRANE BYOTHERS. WRAP FLASHING TAPE25mm AROUND PIPE AND 100mmONTO SARKING

CAVITY PACKER TO SUPPORT SHEETEDGE

TIMBER PACKING INSTALLED BYBUILDER

20mm CAVITY

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

PIPE PENETRATION - CAVITYNOVEMBER 2010

COMMENT: WHERE POSSIBLEPIPE PENETRATIONS SHOULD BEINSTALLED SLOPING DOWN

Page 27: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

SOFFIT DETAIL - CAVITYNOVEMBER 2010

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

20mm CAVITY

INSULCLAD PRE-MESHEDBOARD OR EPS SHEET

NOGGING AS REQUIRED FORINSULCLAD BOARD FIXINGINSTALLED BY THE BUILDER

SOFFIT LINING

CAVITY BATTEN

NOTE:CAVITY MUST NOT BE ALLOWEDTO VENT INTO ROOF SPACE

Page 28: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

15

SOFFIT EDGE DETAIL - CAVITY

CAVITY PACKERS 100mm LONG AT FIXINGS

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

20mm CAVITY

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

PVC L BEND

VENT STRIP

NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRE

SELECTED SOFFIT

Page 29: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

12mm min

VERTICAL CONTROL JOINT - CAVITY

SELECTED PLASTER FINISH

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

PVC L BEND

ADDITIONAL FRAMING WILLBE REQUIRED WITH 35mm STUDS

CAVITY BATTEN

PEF BACKING ROD AND SEALANTBETWEEN 8 - 10mm GAP

Page 30: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

FIXING BLOCK - CAVITYNOVEMBER 2010

100x100mm H3 TREATED TIMBERBLOCKING CUT TO SUIT POLYTHICKNESS AND APPLIED OVERSARKING BY THE BUILDER

SELECTED PLASTER FINISH

CAVITY PACKERS - 100mm LONG

APPROVED BREATHER TYPESARKING INSTALLED BY BUILDER

WATERPROOF MEMBRANE PATCHMUST COVER ALL SIDES OFFIXING BLOCK BY 50mm

Page 31: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

35

80

15

INTERSTOREY DRAINAGE JOINT - CAVITYNOVEMBER 2010

SELECTED PLASTER FINISH

NOTE:THIS DETAIL IS REQUIRED AT THE SECOND STOREY JOIST LEVELPUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF1000mm² PER LINEAL METRE

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

CAVITY PACKERS - 100mm LONGAT FIXINGS

APPROVED BREATHER TYPESARKING INSTALLED BY BUILDER

5mm GAP

METAL FLASHING WITH A 15°SLOPE EXTENDING 75mm BEHINDCLADDING AS SUPPLIED ANDINSTALLED BY OTHERS

VENT STRIP

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

Page 32: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

100mm

METER BOX - HEAD AND JAMB - CAVITY

APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER

NOVEMBER 2010

INSULCLAD PRE-MESHED BOARDOR EPS SHEET

SELECTED PLASTER FINISH

PVC L BEND

EXTRA NOGGINGAS REQUIRED

5mm BEAD OF MS SEALANT BACKEDBY A COMPRESSED FOAM BACKING ROD

METER BOX TAPED ONTO SARKINGUSING WATERPROOF MEMBRANE BYBUILDER - TAPE TO EXTEND MIN 100mmONTO SARKING AND MIN. 50mm ONTO BOX

METER BOX

CAVITY BATTEN

20mm CAVITY

JAMB

HEAD

WATERPROOF MEMBRANE TAPE

CAVITY BATTEN

EPS WEDGE TAPED TO SARKING WITHFLASHING TAPE

CAVITY BATTEN

METER BOX

min

100mm GAP LEFT IN CAVITY BATTEN TOALLOW DRAINAGE INTO NEXT CAVITY

Page 33: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

5mm gap

10mm m

in. c

over

35mm min. cover

to flashing

10mm

AS 2047 COMPLIANT

WINDOW JOINERY

REVEAL

POLYURETHANE FOAM

AIRSEAL O

VER PEF ROD

INTERNAL LINING

WINDOW SILL - C

AVITY

NOVEMBER 2010

POLYURETHANE FOAM

AIRSEAL O

VER PEF ROD

10mm

APPROVED PROPRIETARY

BREATHER TYPE SARKING

FOLDED IN

TO O

PENING,

INSTALLED BY BUILDER

REVEAL

WINDOW H

EAD - C

AVITY

NOVEMBER 2010

FLASHING TAPE ALONG SILL,

100mm UP JAMB AND 50mm

ONTO FACE O

F SARKING

EPS BOARD CUT O

N 15°

SLOPE AT SILL

INSULCLAD PLASTER SYSTEM

AS 2047 COMPLIANT

WINDOW JOINERY

SILL FLASHING TO DRAIN W

ATER

FROM SILL AND JAMB

10mm

WIN

DOW JAMB - C

AVITY

NOVEMBER 2010

APPROVED PROPRIETARY BREATHER

TYPE SARKING FOLDED IN

TO

OPENING, IN

STALLED BY BUILDER

INSULCLAD PRE-M

ESHED BOARD

OR EPS SHEET

PVC L BEND

SEALANT JOINT

FLASHING TAPE TO CORNERS

AS 2047 COMPLIANT

WINDOW JOINERY

REVEAL

POLYURETHANE FOAM

AIRSEAL O

VER PEF ROD

INTERNAL LINING

INSULCLAD PLASTER SYSTEM

APPROVED PROPRIETARY

BREATHER TYPE SARKING

FOLDED IN

TO O

PENING,

INSTALLED BY BUILDER

INSULCLAD PRE-M

ESHED BOARD

OR EPS SHEET

PVC L BEND

ADDITIO

NAL FLASHING TAPE O

VER

HEAD FLASHING AND SARKING

STOPENDS TO HEAD FLASHING

CAVITY PACKERS 100mm LONG AT FIXINGS

CAVITY BATTENS

Page 34: INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved proprietary breather type sarking installed by builder november 2010 insulclad pre-meshed

DOOR

WINDOW

Foundation

Control joint

Selected Flooring

Ceiling Batten Soffit Ribbon Plate

Floor Joist

Battens or packerslocated no closerthan 100mm fromedge of opening

Expansionjoint

TYPIC

AL BATTEN LAYOUT

NOTES:

• If additio

nal w

all in

sulatio

n is being in

stalled, th

e sarking m

ust b

e supporte

d by p

olyp

ropyle

ne

builders stra

p stapled along th

e wall a

t 300mm centre

s to

stop th

e wrap bulging.

• All h

oriz

ontal b

atte

ns m

ust b

e applied on a m

inim

um slope of 1

5 degrees and be no lo

nger

than 100mm in

length. (O

nly o

ne horiz

ontal p

acker m

ay b

e placed between vertic

al b

atte

ns.)