Radiography Interpretation of Inter Run LF at filling area Identified joint – 2’’ Sch 80 weld joint was taken by elliptical shot by Ir 192. Linear indication has observed at pipe wall area in “A” segment. And “B” segment is not shown any such a length /width wise indication or near size indication. Asked contractor to do gouging on same weld joint as per the film marked location. Linear indication has observed after some through thickness gouging.

Inter Run LF at Filling Area

  • Upload
    ketasri

  • View
    213

  • Download
    0

Embed Size (px)

DESCRIPTION

lack of fusion in small bore piping

Citation preview

Radiography Interpretation of Inter Run LF at filling area

Identified joint 2 Sch 80 weld joint was taken by elliptical shot by Ir 192. Linear indication has observed at pipe wall area in A segment. And B segment is not shown any such a length /width wise indication or near size indication.Asked contractor to do gouging on same weld joint as per the film marked location. Linear indication has observed after some through thickness gouging.