INSTRUMENT TRANSFORMERS. LOW VOLTAGE.INSULATORS AND WALL BUSHINGS.
This document may be subject to changes. Contact ARTECHE to confi rm the characteristics and availability of the products described here.
Moving together
Instrument transformers | Low voltage
CONTENTS
1. Instrument transformers. Low voltage.
Current transformers › Metering. Indoor • IFG-5 | 6 • IFP-0 | 6 • IFW-4 / IFW-5 | 7 • IFX | 7
› Metering and protection. Indoor • IFE | 8 • IFG-7 / IFG-8 | 9 • IFH-6 | 10 • IFP-1 | 11 • IFW-0-DS / IFW-4-DS | 11
› Metering and protection. Indoor / Outdoor • IFH-0 | 12 • IFH-1 | 13 • IFH-3 | 14 • IFH-4 | 15 • IFH-5 | 16 • IFH-7 | 17 • IFH-10 | 18 • IFH-12 | 19
› Protection. Split-core • BAT | 20 • BAR | 20 • BAS | 21
› Homopolar. Indoor / Outdoor • BAR | 22 • IFH-3 | 23 • ICO-3 | 23
› Window type for bushings • BUSHING CT | 24
› Auxiliary • IRM | 24
Voltage Transformers
› Metering and protection. Indoor • URC | 25
2. Insulators and wall bushings
› Support insulators. Indoor • AR | 27
› Signal insulators. Indoor • ARC | 28
› Signalling box • LAF-1 | 28
› Wall bushings. Indoor • PRL / PI / PRU / PRP | 30 • PBD | 31 • PBE | 31 • PPL | 32
› Wall bushings. Indoor • PPE-36 | 33
3. Manufacturing and technology | 34
4. Quality and environment | 36
5. Service | 38
4 Instrument transformers | Low voltage
1. INSTRUMENT TRANSFORMERS. LOW VOLTAGE
Current Transformers Voltage Transformers
5Instrument transformers | Low voltage
CURRENT TRANSFORMERS>> WINDOW TYPE
Current transformers without primary winding intended to be used in low voltage bars or isolated cables.
RANGE
› Primary nominal currents up to 10,000 A. › Secondary currents 1 and 5 A. › Frequencies 50 Hz and 60 Hz.
APPLICATIONS
› Low voltage panels. › Motor control. › Primary distribution switchgear. › Secondary distribution switchgear. › Capacitor banks. › Power generation. › Dead tank circuit breaker. › Railway.
ADVANTAGES
› Wide range of models with different window sizes available.
› Multi-ratio transformer for different transformation ratios available.
› Sealable cover for secondary terminals. › Stainless steel screws available. › Designs for outdoor service available. › Transformer can be assembled in any position.
› Split core current transformers to install without handling the primary bars or cables.
>> SQUARE WINDOW TYPE
Current transformers for installation in low voltage panel bars where available space is critical.
RANGE
› Primary nominal currents up to 3,000 A. › Secondary currents 1 and 5 A. › Frequencies 50 Hz and 60 Hz.
APPLICATIONS
› Low voltage panels.
ADVANTAGES
› Variety of models with diff erent window sizes available.
› Sealable cover for secondary terminals.
>> WITH PRIMARY BAR
Transformers for installation in low voltage measuring panels.
RANGE
› Primary nominal currents up to 1,000 A. › Secondary currents 1 and 5 A. › Frequencies 50 Hz and 60 Hz.
APPLICATIONS
› Low voltage panels.
ADVANTAGES
› Mechanism for fastening the transformer onto the bar.
› Sealable cover for secondary terminals. › Connection for voltage tap.
Instrument transformers | Low voltage6
IFG-5
1. CURRENT TRANSFORMERS > Metering > Indoor
IFP-0
145110 a 115
= =
145110 a 115
6,5
30 333,
53,
5
63,
52,
262,
26
Secondary terminals M4
8043
E
Sealable cover
Secondary terminals M4
ø 70
101
93,
5 ø 22
CHARACTERISTICS
Primary current
ACL0,2 VA CL0,5 VA CL1 VA
5075 4
100 7,5125 10150 15200 15 30250 20 40300 30 50400 30 35500 15 35 40600 20 50 60
60
627385
CHARACTERISTICS
Primary current
A
Marks A and B
Mark C
Cl 0.5 Fs5 VA5
10 and 15
102030405075
100150200
10 and 15300400500600
Thermal Current: 60xIn
DIMENSIONS
Mark Current EA Up to 300 A 5B From 200 to 600 A 10
Sealable cover
9085
90 10
6
40
P1K
P2L
S1k
S2l
30,25
10,2
5
With passing-through holeMARK C - From 200 to 600 A
102
7Instrument transformers | Low voltage
IFW-4 • IFW-5
1. CURRENT TRANSFORMERS > Metering > Indoor
Secondary terminals M4
D B
A
C
Sealable cover
H
65
G
F
E
Screws to fi x transformer on busbar
DIMENSIONS
Type A B C D E F G HIFW-4 62 105 150 193 75 50 78 85,5IFW-5 95 105 190 200 75 50 78 85,5
IFX Secondary terminals M4
B D
AC
F
DIMENSIONS
Type A B C D E F GIFX-0 22 82 85 135 80 48 58IFX-1 22 102 88 168 74,5 50 55IFX-2 32 102 102 172 64 56 50
CHARACTERISTICS
TypePrimary current
A
CL0,5 VA
CL1 VA
IFW-43000
15 30
35004000
IFW-5350040005000
CHARACTERISTICS
TypePrimary current
A
CL0,5 SFS 5 VA
IFX-0
400*
10
500*600*750*800*1000*1200*
10 and 151250*
1500*
IFX-1
750*
10
800*1000*1200*1500*2000*
IFX-22000*2500*3000*
*Extended current rating up: 150%Thermal Current: 60xIn
Sealable cover
G
E Screws to fi x
transformer on busbar
Instrument transformers | Low voltage8
IFE
1. CURRENT TRANSFORMERS > Metering and protection > Indoor
DIMENSIONS
Type Mark A B C D(±1,5) E F G H
IFE-1 120 81 83,5 60 40 145 50 164,5
IFE-3A
120 103 10660
35 190 55 209B 80
Ø F
B
H
Ø D
C
A
1,5
105= =
25==
Ø 7
CHARACTERISTICS
SINGLE PRIMARY RATIO AND ONE SECONDARY
Inner diameterØ D= 60 mm
Inner diameterØ D= 80 mm
Type Primary current A
Class and burdenMETERING
Class and burdenPROTECTION
Class and burdenMETERING
Class and burdenPROTECTION
IFE-1
200 5 VA CL1 2,5 VA 5P10250 12,5 VA CL1 2,5 VA 5P10300 5 VA CL0,5 2,5 VA 5P10400 12,5 VA CL0,5 5 VA 5P10
500 5 VA CL0,225 VA CL0,5
5 VA 5P102,5 VA 5P15
600 10 VA CL0,250 VA CL0,5
5 VA 5P102,5 VA 5P20
800 20 VA CL0,280 VA CL0,5
7,5 VA 5P102,5 VA 5P15
1000 40 VA CL0,2100 VA CL0,5
10 VA 5P102,5 VA 5P15
1200 70 VA CL0,2120 VA CL0,5
10 VA 5P105 VA 5P15
IFE-3
150 35 VA CL3 2,5 VA 5P10 25 VA CL3 2,5 VA 5P10
200 2,5 VA CL0,510 VA CL1
5 VA 5P105 VA 5P10
5 VA CL130 VA CL3
2,5 VA 5P102,5 VA 5P15
250 5 VA CL0,520 VA CL1
7,5 VA 5P102,5 VA 5P20
2,5 VA CL0,510 VA CL1
5 VA 5P102,5 VA 5P15
300 7,5 VA CL0,535 VA CL1
7,5 VA 5P102,5 VA 5P20
5 VA CL0,520 VA CL1
5 VA 5P102,5 VA 5P20
400 5 VA CL0,220 VA CL0,5
10 VA 5P105 VA 5P20
10 VA CL0,545 VA CL1
7,5 VA 5P102,5 VA 5P20
500 10 VA CL0,240 VA CL0,5
15 VA 5P105 VA 5P20
5 VA CL0,225 VA CL0,5
10 VA 5P102,5 VA 5P20
600 15 VA CL0,275 VA CL0,5
15 VA 5P107,5 VA 5P20
10 VA CL0,240 VA CL0,5
12,5 VA 5P105 VA 5P20
800 40 VA CL0,2175 VA CL0,5
20 VA 5P1010 VA 5P20
20 VA CL0,2100 VA CL0,5
15 VA 5P105 VA 5P20
1000 75 VA CL0,2200 VA CL0,5
30 VA 5P1012,5 VA 5P20
45 VA CL0,2150 VA CL0,5
20 VA 5P107,5 VA 5P20
1200 100 VA CL0,2 30 VA 5P1012,5 VA 5P20
70 VA CL0,2175 VA CL0,5
25 VA 5P1010 VA 5P20
1500 125 VA CL0,2 25 VA 5P1010 VA 5P20
2000 200 VA CL0,2 35 VA 5P1010 VA 5P20
G
E
9Instrument transformers | Low voltage
› IFG-7
IFG-7 • IFG-8
DIMENSIONS
Type AIFG-7 55IFG-8 85 Ø 5
0
147 16
0
1,5
Ø 125 A
90= =
2,52,5
33=
=
593,
53,
52,
252,
256,5
110
==
1. CURRENT TRANSFORMERS > Metering and protection > Indoor
CHARACTERISTICS
SINGLE PRIMARY RATIO AND ONE SECONDARY
Type Primary current A
Class and burdenMETERING
Class and burdenPROTECTION
IFG-7
200 2,5 VA CL0,5 2,5 VA 5P10250 5 VA CL0,5 2,5 VA 5P10300 7,5 VA CL0,5 2,5 VA 5P15
400 2,5 VA CL0,220 VA CL0,5
5 VA 5P102,5 VA 5P15
500 7,5 VA CL0,240 VA CL0,5
5 VA 5P102,5 VA 5P20
600 15 VA CL0,260 VA CL0,5
7,5 VA 5P102,5 VA 5P20
800 35 VA CL0,290 VA CL0,5
7,5 VA 5P102,5 VA 5P15
1000 60 VA CL0,2120 VA CL0,5
12,5 VA 5P102,5 VA 5P20
IFG-8
100 25 VA CL3 2,5 VA 5P10150 7,5 VA CL1 2,5 VA 5P15200 5 VA CL0,5 2,5 VA 5P10
250 5 VA CL0,520 VA CL1
5 VA 5P102,5 VA 5P15
300 2,5 VA CL0,215 VA CL0,5
10 VA 5P102,5 VA 5P20
400 7,5 VA CL0,240 VA CL0,5
12,5 VA 5P105 VA 5P20
500 15 VA CL0,275 VA CL0,5
15 VA 5P105 VA 5P20
600 30 VA CL0,2125 VA CL0,5
15 VA 5P107,5 VA 5P20
800 70 VA CL0,2180 VA CL0,5
20 VA 5P107,5 VA 5P20
1000 125 VA CL0,2240 VA CL0,5
30 VA 5P1010 VA 5P20
P2
Instrument transformers | Low voltage10
IFH-6
Ø 260
141
325 Ø D
290
L
195
= =
98
==
Ø 9
118
220
1. CURRENT TRANSFORMERS > Metering and protection > Indoor
DIMENSIONS & CHARACTERISTICS
D L MarkPrimary current
AMETERING PROTECTION METERING + PROTECTION
60
130 I
100 5 VA CL1 5 VA 5P20200 10 VA CL0,5 12,5 VA 5P20 5 VA CL1 + 7,5 VA 5P20400 15 VA CL0,2 25 VA 5P20 10 VA CL0,5 + 15 VA 5P20600 15 VA CL0,2S 40 VA 5P20 15 VA CL0,2 + 15 VA 5P201000 70 VA CL0,2S 70 VA 5P20 15 VA CL0,2S + 30 VA 5P20
180 B
100 7,5 VA 5P20 5 VA CL3 + 5 VA 5P20200 20 VA 5P20 5 VA CL1 + 15 VA 5P20400 40 VA 5P20 15 VA CL0,5 + 25 VA 5P20600 60 VA 5P20 15 VA CL0,2S + 35 VA 5P201000 100 VA 5P20 15 VA CL0,2S + 60 VA 5P20
225 E
100 10 VA 5P20 5 VA CL3 + 7,5 VA 5P20200 25 VA 5P20 10 VA CL1 + 20 VA 5P20400 55 VA 5P20 20 VA CL0,5 + 40 VA 5P20600 85 VA 5P20 15 VA CL0,2 + 60 VA 5P201000 140 VA 5P20 15 VA CL0,2S + 90 VA 5P20
80
130 J
100 15 VA CL3 5 VA 5P20200 5 VA CL0,5 12,5 VA 5P20 2,5 VA CL0,5 + 5 VA 5P20400 10 VA CL0,2 25 VA 5P20 12,5 VA CL0,5 + 12,5 VA 5P20600 35 VA CL0,2 40 VA 5P20 15 VA CL0,2 + 15 VA 5P201000 40 VA CL0,2S 70 VA 5P20 15 VA CL0,2S + 20 VA 5P202000 300 VA CL0,2S 135 VA 5P20 15 VA CL0,2S + 65 VA 5P20
180 C
100 7,5 VA 5P20200 20 VA 5P20 2,5 VA CL0,5 + 12,5 VA 5P20400 40 VA 5P20 12,5 VA CL0,5 + 25 VA 5P20600 65 VA 5P20 15 VA CL0,2 + 35 VA 5P201000 100 VA 5P20 15 VA CL0,2S + 60 VA 5P202000 200 VA 5P20
225 F
100 10 VA 5P20200 25 VA 5P20 10 VA CL1 + 20 VA 5P20400 55 VA 5P20 20 VA CL0,5 + 40 VA 5P20600 85 VA 5P20 12,5 VA CL0,2 + 60 VA 5P201000 140 VA 5P20 15 VA CL0,2S + 90 VA 5P20
110 130 L
100 15 VA CL3 5 VA 5P20200 5 VA CL0,5 12,5 VA 5P20 2,5 VA CL0,5 + 5 VA 5P20400 7,5 VA CL0,2 25 VA 5P20 12,5 VA CL0,5 + 12,5 VA 5P20600 35 VA CL0,2 40 VA 5P20 15 VA CL0,2 + 15 VA 5P201000 40 VA CL0,2S 70 VA 5P20 15 VA CL0,2S + 20 VA 5P20
130
130 A
200 15 VA CL1 10 VA 5P20 5 VA CL1 + 5 VA 5P20400 30 VA CL0,5 20 VA 5P20 5 VA CL0,5 + 10 VA 5P20600 20 VA CL0,2 30 VA 5P20 7,5 VA CL0,2 + 15 VA 5P201000 25 VA CL0,2S 50 VA 5P20 20 VA CL0,2 + 25 VA 5P201500 85 VA CL0,2S 75 VA 5P20 20 VA CL0,2 S + 25 VA 5P202000 200 VA CL0,2S 100 VA 5P20 25 VA CL0,2S + 50 VA 5P20
180 D
200 15 VA 5P20 7,5 VA CL1 + 7,5 VA 5P20400 30 VA 5P20 15 VA CL0,5 + 15 VA 5P20600 45 VA 5P20 10 VA CL0,2 + 25 VA 5P201000 80 VA 5P20 10 VA CL0,2 S + 45 VA 5P20
225 G
200 20 VA 5P20 7,5 VA CL1 + 12,5 VA 5P20400 45 VA 5P20 15 VA CL0,5 + 25 VA 5P20600 65 VA 5P20 7,5 VA CL0,2 + 45 VA 5P201000 115 VA 5P20 7,5 VA CL0,2 S + 70 VA 5P20
160 225 K
200 7,5 VA CL1 10 VA 5P20400 15 VA CL0,5 20 VA 5P20 7,5 VA CL0,5 + 10 VA 5P20600 12,5 VA CL0,2 25 VA 5P20 20 VA CL0,5 + 15 VA 5P201000 10 VA CL0,2S 50 VA 5P20 25 VA CL0,2 + 25 VA 5P201500 50 VA CL0,2S 55 VA 5P20 15 VA CL0,2 S + 40 VA 5P20
205 180 H1000 15 VA CL0,5 15 VA 5P10 10 VA CL0,5 + 10 VA 5P101200 20 VA CL0,5 20 VA 5P10 15 VA CL0,5 + 15 VA 5P101600 25 VA CL0,5 25 VA 5P10 10 VA CL0,5 + 10 VA 5P10
70 225 M
100 10 VA 5P20 5 VA CL3 + 7,5 VA 5P20200 25 VA 5P20 10 VA CL1 + 20 VA 5P20400 55 VA 5P20 20 VA CL0,5 + 40 VA 5P20600 85 VA 5P20 15 VA CL0,2 + 60 VA 5P201000 140 VA 5P20 15 VA CL0,2S + 90 VA 5P20
11Instrument transformers | Low voltage
IFP-1
1. CURRENT TRANSFORMERS > Metering and protection > Indoor
147
With passing - Through holeMARK B - From 250 to 1000 A
MARK A - Up to 1.000 A
IFW-O/DS • IFW-4/DS
Sealable cover Secondary terminals M4
D B 35
AC
E
FG
Screws to fi x transformer on busbar
DIMENSIONS
Type A B C D E F GIFW-0/DS 20 62 84 126 126 80 105IFW-4/DS 62 105 150 193 136 90 115
125
1025 25
M12
225175
= =
=145
=
50=
=
145
120
Ø6,5
145
72,5
166
6
CHARACTERISTICS
Type Ratio(A)
Burden VA PROTECTION
Ratio(A)
Class and burdenMETERING + PROTECTION
IFW-O/DS
250/5 7,5 VA 10P5300/5 10 VA 10P5350/5 12,5 VA 10P5
400/5 15 VA 10P5 or5 VA 5P10
500/5 15 VA 10P5 or7,5 VA 5P10 500/5-5 10 VA CL1 + 5 VA 5P10
5 VA 10P10
600/5 20 VA 10P5 or10 VA 5P10 600/5-5 10 VA CL1 + 7,5 VA 5P10
7,5 VA 10P10
1000/5 30 VA 10P5 or15 VA 5P10 1000/5-5 15 VA CL0,5 + 10 VA 5P10
10 VA 10P10
1250/5 30 VA 10P5 or15 VA 5P10 1250/5-5 15 VA CL0,5 + 10 VA 5P10
12,5 VA 10P10
1500/5 40 VA 10P5 or20 VA 5P10 1500/5-5 15 VA CL0,5 + 15 VA 5P10
15 VA 10P10
IFW-4/DS
2000/5 45 VA 10P520 VA 5P10 2000/5-5 15 VA CL0,5 + 15 VA 5P10
20 VA 10P10
2500/5 40 VA 10P530 VA 5P10 2500/5-5 15 VA CL0,5 + 20 VA 5P10
25 VA 10P10
3000/5 40 VA 10P530 VA 5P10 3000/5-5 15 VA CL0,5 + 25 VA 5P10
30 VA 10P10
3500/5 40 VA 10P530 VA 5P10 3500/5-5 15 VA CL0,5 + 25 VA 5P10
30 VA 10P10
4000/5 45 VA 10P540 VA 5P10 4000/5-5 15 VA CL0,5 + 30 VA 5P10
35 VA 10P10
10,2
550,25
CHARACTERISTICS
Mark Primary current A
CL0,2VA
SP10VA
A
5 to 250 30 20300 15 15400
30
20600 30800 35900 40
1.000 45
B
300 15 15400
30
20500 25600 30800 35900 40
1.000 45
Thermal Current: 60xIn
Instrument transformers | Low voltage12
1. CURRENT TRANSFORMERS > Metering and protection > Indoor / Outdoor
IFH-0Ø
60
260
Secondary terminals M6 (max. 6)
Indoor serviceMark A
M8
226
,5
106
PG 16
113
Secondary terminals M6 (max. 6)
89
,557
,5
Outdoor serviceMark B
==
Ø 136
0
90
170==
200==
==
PG 16
45
CHARACTERISTICS
ONE SECONDARY TWO SECONDARIES
Primary current A METERING PROTECTION METERING + PROTECTION
100 5 VA 5P10150 10 VA CL1 10 VA 5P10200 25 VA CL1 10 VA 5P10 5 VA CL1 + 10 VA 5P5250 25 VA CL1 15 VA 5P10 15 VA CL1 + 5 VA 5P10300 20 VA CL0,5 15 VA 5P10 20 VA CL1 + 5 VA 5P10400 40 VA CL0,5 20 VA 5P10 15 VA CL0,5 + 10 VA 5P10500 50 VA CL0,5 30 VA 5P10 15 VA CL0,5 + 15 VA 5P10600 50 VA CL0,5 15 VA 5P20 20 VA CL0,5 + 20 VA 5P10750 65 VA CL0,5 20 VA 5P20 30 VA CL0,5 + 25 VA 5P10800 40 VA CL0,5 + 30 VA 5P101000 30 VA CL0,2 25 VA 5P20 50 VA CL0,5 + 35 VA 5P101200 30 VA CL0,2 30 VA 5P20 50 VA CL0,5 + 45 VA 5P10
Ø 165
13Instrument transformers | Low voltage
IFH-1
1. CURRENT TRANSFORMERS > Metering and protection > Indoor / Outdoor
CHARACTERISTICS
INNER DIAMETER (ØD= 60 mm) INNER DIAMETER (ØD= 80 mm)
ONE SECONDARY TWO SECONDARIES ONE SECONDARY TWO SECONDARIES
Primary current
AMETERING PROTECTION METERING + PROTECTION METERING PROTECTION METERING + PROTECTION
75 15 VA CL3 7,5 VA 10P10 10 VA CL3 10 VA 10P5100 50 VA CL3 12,5 VA 5P10 40 VA CL3 7,5 VA 10P10150 20 VA CL1 15 VA 5P10 30 VA CL3 + 10 VA 5P10 10 VA CL1 12,5 VA 5P10 20 VA CL3 + 5 VA 5P10200 10 VA CL0,5 20 VA 5P10 10 VA CL1 + 12,5 VA 5P10 25 VA CL1 7,5 VA 5P20 5 VA CL1 + 7,5 VA 5P10250 20 VA CL0,5 25 VA 5P10 20 VA CL1 + 15 VA 5P10 12,5 VA CL0,5 10 VA 5P20 10 VA CL1 + 10 VA 5P10300 40 VA CL0,5 15 VA 5P20 10 VA CL0,5 + 20 VA 5P10 20 VA CL0,5 12,5 VA 5P20 15 VA CL1 + 12,5 VA 5P10400 90 VA CL0,5 25 VA 5P20 10 VA CL0,5 + 15 VA 5P20 50 VA CL0,5 15 VA 5P20 10 VA CL0,5 + 15 VA 5P10500 50 VA CL0,2 30 VA 5P20 20 VA CL0,5 + 25 VA 5P20 25 VA CL0,2 20 VA 5P20 12,5 VA CL0,5 + 5 VA 5P20600 75 VA CL0,2 35 VA 5P20 30 VA CL0,5 + 25 VA 5P20 40 VA CL0,2 20 VA 5P20 20 VA CL0,5 + 15 VA 5P20800 100 VA CL0,2 50 VA 5P20 15 VA CL0,2 + 35 VA 5P20 100 VA CL0,2 30 VA 5P20 40 VA CL0,5 + 20 VA 5P201000 100 VA CL0,2 60 VA 5P20 30 VA CL0,2 + 45 VA 5P20 100 VA CL0,2 35 VA 5P20 20 VA CL0,2 + 25 VA 5P201200 100 VA CL0,2 60 VA 5P20 50 VA CL0,2 + 50 VA 5P20 100 VA CL0,2 45 VA 5P20 30 VA CL0,2 + 30 VA 5P201500 100 VA CL0,2 50 VA 5P20 50 VA CL0,2 + 40 VA 5P202000 100 VA CL0,2 75 VA 5P20 100 VA CL0,2 + 40 VA 5P20
Ø 45
25729
0
Secondary terminals M6 (max. 6)
Indoor service
M8
PG 16
125
Secondary terminals M6 (max. 6)
107,
557
,5
Outdoor service
PG 16
Ø D Ø 120
Ø 190
20
==
Ø 11
60
90
170==
200==
==
45
13567,5 67,5
DIMENSIONS
Mark Ø D (±1,5) Service
A 60Outdoor
B 80C 60
IndoorD 80
P1
Instrument transformers | Low voltage14
1. CURRENT TRANSFORMERS > Metering and protection > Indoor / Outdoor
IFH-3
Ø 45°
290
323
Secondary terminals M6 (max. 6)
Indoor serviceMark A
M8
PG 16
144
Secondary terminals M6 (max. 6)
121,5
Outdoor serviceMark B
PG 16
Ø 110
Ø 150
Ø 220
20
==
Ø 11
60
90
170==
200==
==
45
CHARACTERISTICS
ONE SECONDARY TWO SECONDARIES
Primary current
AMETERING PROTECTION METERING + PROTECTION
150 5 VA CL1 5 VA 5P20
200 15 VA CL1 5 VA 5P20
250 5 VA CL0,5 10 VA 5P20
300 12,5 VA CL0,5 10 VA 5P20 5 VA CL1 + 5 VA 5P20
350 20 VA CL0,5 12,5 VA 5P20 5 VA CL0,5 + 5 VA 5P20
400 20 VA CL0,5 15 VA 5P20 5 VA CL0,5 + 7,5 VA 5P20
500 25 VA CL0,5 20 VA 5P20 10 VA CL0,5 + 10 VA 5P20
600 50 VA CL0,5 20 VA 5P20 12,5 VA CL0,5 + 12,5 VA 5P20
1000 50 VA CL0,5 20 VA 5P20
1500 50 VA CL0,5 20 VA 5P20 30 VA CL0,5 + 30 VA 5P20
2000 50 VA CL0,5 20 VA 5P20
3000 50 VA CL0,5 20 VA 5P20 30 VA CL0,5 + 30 VA 5P20
57,5
115= =
M8 (on request)
Ø 9
0°
P1
15Instrument transformers | Low voltage
IFH-4 Secondary terminals M5 (max. 9) Secondary terminals M6
Indoor serviceMark A
131
289
205
Outdoor serviceMark B
==
60 90
170==
200==
==
Secondary terminals M5 (max. 9) Secondary terminals M6
171= =
125
107
Ø 190
Ø 85
PG 16
M8
1. CURRENT TRANSFORMERS > Metering and protection > Indoor / Outdoor
CHARACTERISTICS
ONE SECONDARY TWO SECONDARIES
Primary current
AMETERING PROTECTION METERING + PROTECTION
100 5 VA CL1 5 VA 5P20
150 15 VA CL1 10 VA 5P20 5 VA CL1 + 5 VA 5P20
200 7,5 VA CL0,5 12,5 VA 5P20 15 VA CL1 + 7,5 VA 5P20
300 30 VA CL0,5 20 VA 5P20 15 VA CL0,5 + 10 VA 5P20
400 15 VA CL0,2 25 VA 5P20 7,5 VA CL0,2 + 10 VA 5P20
500 30 VA CL0,2 30 VA 5P20 15 VA CL0,2 + 15 VA 5P20
700 20 VA CL0,2 45 VA 5P20 10 VA CL0,2S + 20 VA 5P20
1000 60 VA CL0,2 65 VA 5P20 25 VA CL0,2S + 25 VA 5P20
2000 400 VA CL0,2 100 VA 5P20 100 VA CL0,2S + 50 VA 5P20
Ø 11
Instrument transformers | Low voltage16
IFH-5
› IFH-5Side mouning on request
instalation horizontal or vertical
25735
2
Secondary terminals M6 (max. 6)
Indoor service
M8
PG 16
157
137,
557
,5
Outdoor service
PG 16
Ø D Ø 250
Ø 15
170
DIMENSIONS
Mark D (±1,5) ServiceA 100
OutdoorB 130C 100
IndoorD 130E 145 OutdoorF 145 Indoor
==
Ø 11
60 90
170==
200==
==
45
= =
Secondary terminals M6 (max. 6)
On request
1. CURRENT TRANSFORMERS > Metering and protection > Indoor / Outdoor
CHARACTERISTICS
ONE SECONDARY TWO SECONDARIES
Inner diameter(ØD= 100 mm)
Inner diameter(ØD= 130 mm)
Inner diameter(ØD= 145 mm)
Inner diameter (ØD= 100 mm)
Inner diameter(ØD= 130 mm)
Primary current A PROTECTION METERING + PROTECTION
200 20 VA 5P20 12,5 VA 5P20 5 VA 5P20 10 VA CL3 + 1 ÷ 10 VA 5P20 7,5 VA CL1 + 7,5 VA 5P20250 25 VA 5P20 15 VA 5P20 7,5 VA 5P20 15 VA CL1 + 15 VA 5P20 15 VA CL1 + 10 VA 5P20300 30 VA 10P20 20 VA 5P20 10 VA 5P20 10 VA CL0,5 + 15 VA 5P20 5 VA CL0,5 + 10 VA 5P20500 45 VA 10P20 30 VA 5P20 15 VA 5P20 25 VA CL0,5 + 25 VA 5P20 20 VA CL0,5 + 20 VA 5P20750 50 VA 10P20 50 VA 5P20 25 VA 5P20 30 VA CL0,5 + 30 VA 5P20 25 VA CL0,5 + 30 VA 5P20
1000 50 VA 10P20 50 VA 5P20 30 VA 5P20 30 VA CL0,5 + 40 VA 5P20 30 VA CL0,5 + 40 VA 5P202000 50 VA 10P20 50 VA 5P20 50 VA 5P20 30 VA CL0,5 + 40 VA 5P20 30 VA CL0,5 + 40 VA 5P203000 50 VA 10P20 50 VA 5P20 50 VA 5P20 30 VA CL0,5 + 40 VA 5P20 30 VA CL0,5 + 40 VA 5P206000 45 VA 5P20
17Instrument transformers | Low voltage
IFH-7
200
Ø D
Ø 15
Ø 270
220
DIMENSIONS
Mark H D Weight(kg)
1 166
100
402 231 553 296 754 361 90
1. CURRENT TRANSFORMERS > Metering and protection > Indoor / Outdoor
CHARACTERISTICS
Mark Primary current A PROTECTION PROTECTION
1
100 15 VA 5P10 7,5 VA 5P20200 30 VA 5P10 15 VA 5P20300 50 VA 5P10 20 VA 5P20400 60 VA 5P10 30 VA 5P20500 75 VA 5P10 40 VA 5P20
2
50 7,5 VA 5P10 2,5 VA 5P2075 15 VA 5P10 5 VA 5P20
100 25 VA 5P10 10 VA 5P20150 40 VA 5P10 15 VA 5P20250 60 VA 5P10 30 VA 5P20300 70 VA 5P10 35 VA 5P20600 100 VA 5P10 60 VA 5P201000 100 VA 5P10 100 VA 5P20
3
50 10 VA 5P10 5 VA 5P20100 30 VA 5P10 15 VA 5P20200 60 VA 5P10 30 VA 5P20300 100 VA 5P10 50 VA 5P20
450 15 VA 5P10 7,5 VA 5P20100 40 VA 5P10 20 VA 5P20150 60 VA 5P10 30 VA 5P20
PG 21 (on request)
Secondary terminals M6 (max. 6)
PG 21
H15
Instrument transformers | Low voltage18
1. CURRENT TRANSFORMERS > Metering and protection > Indoor / Outdoor
IFH-10
220
Secondary terminals M6 (max. 6)
562
115
PG 16
Ø 2
90
255
M8
5
Ø 450
195= =
Ø 9
110
90
==
CHARACTERISTICS
ONE SECONDARY TWO SECONDARIES
Primary current
AMETERING PROTECTION METERING + PROTECTION
4000
30 VA CL0,5 30 VA 5P20 30 VA CL0,5 + 30 VA 5P2050006000800010000
19Instrument transformers | Low voltage
1. CURRENT TRANSFORMERS > Metering and protection > Indoor / Outdoor
IFH-12
294
168
Ø 534
Ø 300
M8
Z 1:5
8
572 626
Outdoor serviceMark A
Indoor serviceMark B
M8
617
Ø 14
500
470
= =
218
188
==
Outdoor serviceMark C
10
564 45
168
20
Indoor serviceMark D
10564 45
M6
719
669
650
60
0
CHARACTERISTICS
ONE SECONDARY TWO SECONDARIES
Primary current A METERING PROTECTION METERING + PROTECTION
4000
50 VA CL0,5 50 VA 5P20 50 VA CL0,5 + 50 VA 5P2050006000800010000
Instrument transformers | Low voltage20
BAT Secondary terminals M6 Metalic cover
DIMENSIONSMark D
A 130B 180
CHARACTERISTICS
Mark A Mark B
Primary current A METERING PROTECTION METERING PROTECTION
200 5 VA 10P10 2,5 VA 10P10
300 2,5 VA CL1 12,5 VA 10P10 2 VA 10P20400 5 VA CL1 5 VA 5P20 2 VA CL1 2 VA 5P20600 5 VA CL0,5 15 VA 5P20 5 VA CL1 5 VA 5P20800 7,5 VA CL0,5 25 VA 5P20 2,5 VA CL0,5 7 VA 5P201000 15 VA CL0,5 30 VA 5P20 5 VA CL0,5 7,5 VA 5P201200 25 VA CL0,5 35 VA 5P20 7,5 VA CL0,5 10 VA 5P201500 45 VA CL0,5 45 VA 5P20 12,5 VA CL0,5 12,5 VA 5P201800 75 VA CL0,5 55 VA 5P20 25 VA CL0,5 15 VA 5P202000 100 VA CL0,5 65 VA 5P20 50 VA CL0,5 15 VA 5P20
1. CURRENT TRANSFORMERS > Protection. Split-core > Indoor / Outdoor
BAR
CHARACTERISTICS
Primary current A METERING PROTECTION
200 4 VA 10P10300 2 VA 10P20400 2 VA CL1 2 VA 5P20500 5 VA CL1 4 VA 5P20600 7,5 VA CL1 5 VA 5P20800 3 VA CL0,5 7 VA 5P201000 7,5 VA CL0,5 7,5 VA 5P20
S2S1
P1
4
Ø 2
70
Ø D
156
155
PG 16
PAR DE APRIETETORQUE0.5 Kg.m 9
5
200
=170
=
318
R7
TORQUEPAR DE APRIETE
0.5 Kg.m
P1
Secondary terminals M6
Metalic cover
PG 16
200
Ø 190
Ø 105
112
110
230
170
95
80
50
4
R7
21Instrument transformers | Low voltage
1. CURRENT TRANSFORMERS > Protection. Split-core > Indoor / Outdoor
BAS Secondary terminals M6
Metalic cover
DIMENSIONS
Mark DA 70B 105
CHARACTERISTICS
Mark A Mark B
Primary current A METERING PROTECTION METERING PROTECTION
150 5 VA 10P10200 7,5 VA 10P20 3 VA 10P20300 10 VA CL1 12,5 VA 10P20 5 VA 10P20400 5 VA CL0,5 15 VA 5P20 4 VA CL1 7,5 VA 5P20500 12,5 VA CL0,5 20 VA 5P20 12,5 VA CL1 8 VA 5P20600 20 VA CL0,5 30 VA 5P20 15 VA CL1 10 VA 5P20800 7,5 VA CL0,5 12,5 VA 5P201000 25 VA CL0,5 15 VA 5P20
P1
S1 S2
PAR DE APRIETE
0.5 Kg.mTORQUE
200
Ø 190
Ø D
113
111
230
150
80
50
17085=
85=
R7
4
Instrument transformers | Low voltage22
1. CURRENT TRANSFORMERS > Homopolar > Indoor / Outdoor
BAR Secondary terminals M6
Metalic cover
CHARACTERISTICS
Ratio A Characteristics
20/1Burden: 0,1 Oh. Error: at 0,05 In ±15%
at In ±10% at 10 In ±15%
20/1Burden: 0,3 Oh. Error: at 0,05 In ±15%
at In ±10% at 5 In ±15%
30/1Burden: 0,1 Oh. Error: at 0,05 In ±15%
at In ±10% at 10 In ±15%
30/1Burden: 0,3 Oh. Error: at 0,05 In ±15% at In ±10% at 5 In ±15%
50/1Burden: 0,2 Oh. Error: at 0,05 In ±15% at In ±10% at 5 In ±15%
50/1Burden: 0,1 and 1,5 Oh. Error: at 0,05 In ±15% at In ±10% at 10 In ±15%
CCCCuussttttoommiiiizzeedddd ssoolllluuttttiiiioonnss ffffoorr aaannyyy rreeeqqquuuiiirreeemmeeenntttt.
P1
TORQUEPAR DE APRIETE
0.5 Kg.m
PG 16
200
Ø 190
Ø 105
112
110
4
230
170
95
80
50
23Instrument transformers | Low voltage
Secondary terminals M6 (max. 6)
Indoor service
Secondary terminals M6 (max. 6)
Outdoorservice
IFH-3
CHARACTERISTICS
Ratio A Characteristics
10/1Burden: 0,1 Oh. Error: at 0,05 In ±15%
at In ±10% at 10 In ±15%
20/1Burden: 0,1 and 0,3 Oh. Error: at 0,05 In ±15%
at In ±10% at 10 In ±15%
30/1Burden: 0,1 Oh. Error: at 0,05 In ±15%
at In ±10% at 5 In ±15%
50/1Burden: 1 Oh. Error: at 0,05 In ±15%
at In ±10% at 10 In ±15%
60/1Burden: 1 Oh. Error: at 0,05 In ±15%
at In ±10% at 10 In ±15%
1. CURRENT TRANSFORMERS > Homopolar > Indoor / Outdoor
ICO-3
CHARACTERISTICS
Ratio A Characteristics
20/1Burden: 0,1 Oh. Error: at 0,01 In ±15%
at In ±10% at 10 In ±15%
30/1Burden: 0,1 Oh. Error: at 0,05 In ±15%
at In ±10% at 5 In ±15%
50/1Burden: 0,1 Oh. Error: at 0,05 In ±15%
at In ±10% at 5 In ±15%
60/1Burden: 0,1 Oh. Error: at 0,05 In ±15%
at In ±10% at 5 In ±15%
100/1Burden: 0,1 Oh. Error: at 0,05 In ±15% at In ±10% at 5 In ±15%
Ø 45
HA
M8
I
PG 16
BC
E
PG 16
Ø D Ø F
Ø G
20
==
Ø 11
60
90
170==
==
==
200
45
KV
I.ter.I.din.
Hz
TIPOI.pn
I.sn
BORN.
EXT.%
CL
TRANSFORMADOR DE INTENSIDAD
MADE
SPAIN IN
VA
Fs
Kn=$07__$06__ $08__$11__
$19__$15__
$23__$27__$26__
$10__$14__
$22__$18__
$16__$12__
$24__$28__
$20__
$05___________________$02______$01____ N° $03_
$35
$32____
$36__
$33____$34 KA
KA
S
P1
180150
= =
42 57
20
510
470 310
165
145
R45
R90
R45
R90
20
Ø 11
Instrument transformers | Low voltage24
Window type current transformers, bushing type, for installation in power transformers, dead tank circuit breakers or Gas Insulated Switchgears (GIS). They are custom made designed based on the each project requirements.
BUSHING CT
1. CURRENT TRANSFORMERS > Bushing CT > Indoor
1. CURRENT TRANSFORMERS > Auxiliary > Indoor
IRM
CHARACTERISTICS
Type Maximum current (A) METERING PROTECTION A B C D E F G H I J M N
IRM-2Up to 15 A 30 VA CL0,5 10 VA 10P20 143 10 135
80 102 112 108 5 90 72 90 M4From 15 to 100 A 60 VA CL1 10 VA 5P20 163 30 155
IRM-3Up to 15 A 45 VA CL0,5 25 VA 10P20 157 10 150
95 119 135 126
7
105 83 104
M6
From 15 to 100 A 90 VA CL1 20 VA 5P20 177 30 170
IRM-4Up to 15 A 75 VA CL0,5 45 VA 1OP30 197 10 190
120 136 152 150 125 100 125From 15 to 100 A 150 VA CL1 45 VA 5P20 217 30 210
IRM-5Up to 15 A 100 VA CL0,5 60 VA 5P20 217 10 210
From 15 to 100 A 100 VA CL0,5 60 VA 5P20 237 30 230
FM
AB
6
C
Secondary terminals max. 2 of M10 or 5 of M4
Secondary terminals max. 5 of M4
GD
I
E K JHN
25Instrument transformers | Low voltage
1. VOLTAGE TRANSFORMERS > Metering and protection > Indoor
URC
DIMENSIONS
Primary current A
Burden VA Weight(kg)
A B C D E F G H I J MClass 0,5 Class 1 Thermal
URC-52 15 45 200 108 90 111 80 102112
117 5 90 72
M4URC-71 25 60 300
126104
11395
120
7
105 83URC-72 30 70 450120 119 135
127URC-80 10 20 6,2 105 128URC-91 75 150 600
150 125
131
120 136 152
138
125 100 M6URC-92 150 300 900 161 168URC-93 200 400 1300 181 188URC-100 30 70 13,5 161 169
F
C
R
G
Terminals M4
D
I
E B
H
M
A
J
VOLTAGE TRANSFORMERSResin-cast low voltage transformers for measuring and protection.
RANGE
› Insulation level 0.72 kV. › Frequencies: 50 Hz, 60 Hz.
APPLICATIONS
› Low voltage panel.
ADVANTAGES
› Transformer can be assembled in any position.
› Auxiliary services can be supplied.
26 Instrument transformers | Low voltage
2. INSULATORS & WALL BUSHINGS Support insulators Signal insulators Signalling box Wall bushings
27Instrument transformers | Low voltage
2. INSULATORS AND WALL BUSHINGS > Support insulators > Indoor
AR
CHARACTERISTICS AND DIMENSIONS
Type
Highest system voltage
kV
Rated insulation level Mimimum breaking
stress P (kg)
No sheeds
Weight(kg)
Creepage distance
H (±0,5)
Ø Máx.
Dd1 d2 t1 fLigthning
Impulse (BIL) kV
Power frequency kV
AR-8-60 7,2 60 80
800
3 0,7 200 95
100
56 M1626 35
AR-8-75 12 7538
4 0,98 272 130 64 M16AR-8-95 17,5 95 6 1,37 340 175 69 M20 35
45AR-8-125 24 125 50 7 1,65 397 210 74 M20 45AR-8-170 36 170 70 11 2,57 555 300 84 M24 51 60
View from X
Pe
24
15
70
D
H
M10
M16
t1
10d2
d1
46
6,5f
8
X
Instrument transformers | Low voltage28
2. INSULATORS AND WALL BUSHINGS > Signalling box > Indoor
LAF-1
1 - Test light2 - Fixed warning block3 - Insulators
LAF-1 Application
Assembly sketch
ARC
CHARACTERISTICS AND DIMENSIONS
TypeHighest system
voltage kV
Ligthning Impulse (BIL) kV
Power frequency
kV
kVmin.
kV max.
Height(kg)
Creepage distance
H (±0,5) d1 f A B Ø C
ARC-8-40 3,6 40 10 1,2 3,60,98 272 130 64 23 26 12
16
ARC-8-60 7,2 60 20 2,4 7,2ARC-8-75 12 75 28 4 12ARC-8-95 17,5 95 38 5,8 17,5
1,65 397 210 7428 28 10ARC-8-125 24 125 50 8 24
ARC-8-170 36 170 70 12 36 2,60 555 300 84
View from B
Minimum failing load: 4000 Newton
2. INSULATORS AND WALL BUSHINGS > Signal insulators > Indoor
View from A
24
36
f
M4
24
B
Ø 70
Ø 100
H
M12
C10
M16d1
M6
A
A
B
Pe
41
82
110
41
120 58
70
12
2 1 100
110
74
Ø 4,5
R S T
LAF-1
3
Die-cast
29Instrument transformers | Low voltage
ARTECHE transformers are installed in over 150 countries.
Instrument transformers | Low voltage30
› PRL
› PRU › PRP
2. INSULATORS AND WALL BUSHINGS > Bushings > Indoor
PRL - PRU - PRP
CHARACTERISTICS AND DIMENSIONS
Type
Highest system voltage
kV
Ligthning Impulse
(BIL) kV
Barsmax.
Currentmax.
Weight
(kg)A B C D d E F G H J K S T
PRL-1212 75
30
1.000
1,6 285 135 83 77 31 110 130 11015 M10
85PRU-12/75 60 2,3
255 110115 115 68 160 200 160 120 65 20
PRU-12/115 100 3,5 160 160 110 205 250 200 165 105 40PRL-24
24 12530 4,5
425 200125 108 31 145 185 130
24 M12115
PRU-24/115 1002.500
9 185 185 110 230 280 210 190 105 40PRP-36 36 170 120 32,5 560 275 220 220 120 250 300 300 25 20 257
Detail (striped)Useful zone to place conductor elements
Ø d
B
H
10
Ø J
A
Ø D
120
Ø C
FE
50
Ø 180
Detail (striped)Useful zone to place conductor elements
Ø C
F
10B
H
Ø KØ J
E
G
A
Ø D
T
Ø S
Ø C
F
10B
H
Ø D
Ø K
Ø d
Ø J
E
G
A
31Instrument transformers | Low voltage
2. INSULATORS AND WALL BUSHINGS > Bushings > Indoor
PBD
PBEP1
40
536
014
0
Ø C
360405
Ø 4
22
Ø D
M8
290,5
14
Screw at screen potential
B
A8
DIMENSIONS
Type A B C DPBE-12 255 550 227 275PBE-24 230 500 225 200
PBD-17
P1
380325
162,5 162,5
Ø 2
85,5
Ø D
210 190400
Screw at screen potential
276
210
M8
105
105
Ø 275
230
115
115
34
P1
PBD-24
Ø 352
192
821
536
0
355310
R 191
181
355
310
120
256
14
M8
Screw at screen potential
Ø 15
0
DIMENSIONS
Type Mark Ø D Weight (kg)
PBD-17A 100
25B 130
PBD-24 45
Instrument transformers | Low voltage32
PPL
2. INSULATORS AND WALL BUSHINGS > Bushings > Indoor
AB B
M12
P1
12 25
C
DE F G H
230= =
Ø 260
365
210
155
Ø 16
280
260
==
Mark D (Option)
20 40 40
Ø 16
Ø 5
0 40
30 120130
I
1510
120
Ø 5
0
Mark E Only PPL-72
(Option)
30
120130
20 40 40
Ø 16
Ø 5
0 40
I
Mark G (On request)
DIMENSIONS
Type A B C D E F G H IPPL-12 706 353 442 38,5
157,5 207,538,5 706
PPL-36 34 716 175,5 175,5 975PPL-72 1.270 451 159 209 451 1.530
TTThhheee iiinnnnnnooovvvaaatttiiiooonnn uuunnndddeeerrrtttaaakkkeeennnbbbbyyy AAAARRRRTTTTEEEECCCCHHHHEEEE iiiinnn iiiinnnssstttrrruuummmeeennnttttttrraannssfffoorrmmeerrss ddduurriiinnggg ttthhheellllaaaatttteeee yyyyeeeeaaaarrrrssss hhhhaaaavvvveeee mmmmaaaaddddeeeettthhheeemmm mmmooorrreee eeeffiffiffi ccciiieeennnttt,, wwwiiittthhhcccooommmpppaaacccttt dddeeesssiiigggnnnsss fffooorrr aaannneasiier transport, store, anddinstallation and to minimizetheir visual impact.
33Instrument transformers | Low voltage
2. INSULATORS AND WALL BUSHINGS > Bushings > Outdoor
PPE-36
L
605
Ø 530
Ø 500
Ø 14
With primary terminal
E max
50
Ø 3
63
ØIn
t. 2
10
25 44,5
44
,510
0
128
Ø 14,25
Aluminium
DIMENSIONS
Type Mark Ø D E max L
With primary terminal
A 320 1412B 400 1492
Without primary terminal
A125
320 1125B 400 1205C
210320 1125
D 400 1205
L460
Without primary terminal
E max
Ø 3
63
ØIn
t. 2
10
TIPO/TYPEN°
AÑO/YEARPESO/WEIGHT
$16___
Ø 530
Ø 500
Ø 14
Ø D
34 Instrument transformers | Low voltage
3. MANUFACTURING AND TECHNOLOGYWith 65 years of experience, ARTECHE guarantees the performance of its transformers regardless of altitude, weather, seismic or environmental conditions.
35Instrument transformers | Low voltage
› Equipment undergoing a continuous i n n ova t i o n p ro c e s s i n c l u d i n g : computerized systems for transformer calculation, analysis of the distribution of the electric field by FEM, automatic winding machines, casting in epoxy resin or polyurethane by gravity in vacuum tanks or pressurized gelifi cation, controlled polymerization in large ovens.
› Own laboratories with modern equipment, approved for any routine or type test, either for new developments or for specifi c requirements from our customers in power generation, transmission, distribution or industry.
› Approved in laboratories belonging to the International Metrology Committee: PTB (Germany), L.C.O.E (Spain), GOST (Russia), BEV (Austria), GUM (Poland) etc.
› Large production capacity of more than 50.000 units per year in medium voltage and an almost unlimited number of devices in low voltage, insulators and wall bushings. This capacity allows us to give a quick answer to any requirement.
› Flexible designs, adapted to any specification, as a result of our strong engineering team located in all our production facilities.
› Maximum safety with res in-cast transformers in which the core and the winding form a compact block. The resin acts as a dielectric support, protective casing and thermal conductor for the transformer.
› Equipment compliant to any international or domestic standard: IEC, IEEE, UNE, BS, VDE, SS, CAN, AS, UL, NBR, JIS, GOST, NF, etc.
MANUFACTURING AND TECHNOLOGY
› Physical and chemical laboratories conduct over 130 tests to certify the quality of raw materials.
IIIIIIInnnnn 2222222000000011111111111111,,, AAAAAAARRRRRRRTTTTTTTEEEEEEECCCCCCCHHHHHHHEEEEEEE iiiiiiinnnnnvvvvveeeeesssssttttttteeeeeddddddd 1111122222 mmmiiiiilllllllllliiiiiooonnn eeeuuurrrooosss iiiiinnntttttooo RRRRR&&&&&DDDDD+++iiiii.
36 Instrument transformers | Low voltage
4. QUALITY & ENVIRONMENT
Exceeding environmental regulations, ARTECHE has been able to minimize the use off hazardous materials, energy consumption and waste generation.
37Instrument transformers | Low voltage
QUALITY & ENVIRONMENTEveryone in the ARTECHE Group works under the criteria set out in our environmental and quality policy.
A sum of regulated procedures based on communication, teamwork, prevention analysis and continuous improvement, common to the whole organization.
› Advanced sustainability criteria in production and in the creation and development of new products.
› Compact designs, manufactured with minimal energy consumption and enviromental-friendly materials.
› Internal and external skill motivation programs.
› Advanced development of knowledge management.
› Quality agreements with utilities. › Phys ico-chemica l and e lect r ica l laboratories for testing under any International Standard.
› Type test reports issued by KEMA, CESI, LAPEM, RENARDIÈRES, etc.
› Final testing according to specific customer requirements.
› Approvals in more than 100 electricity companies.
› ISO 14001:2004. › ISO 9001:2008.
AAAARRRRTTTTEEEECCCCHHHHEEEE’’’ss fifififi nnaanncciiiiaallll aanndddd tttteeeccchhhhnnnooollllooogggiiiicccaaallll iiiinnnddddeeepppeeennnddddeeennnccceee gggiiivveess aa ppprriiivviiillleegggeeddd pppoossiiitttiiioonn aaahhhheeeaaadddd oooffff tttthhhheee ccchhhhaaalllllllleeennnggggeeesss iiiinnn ttthhheee ssseeeccctttooorrr.
38 Instrument transformers | Low voltage
5. SERVICE
Over 70 technical/sales service centers with real knowledge about each customer provide fast and close service.
39Instrument transformers | Low voltage
SERVICE
› The solutions ARTECHE has developed and expanded upon have made it a major player participating in the most signifi cant events and workgroups in the electricity sector.
› ARTECHE’s service is based on a close relationship with the customers, refl ected in the integrated post-sale assistance plan and structured client opinion system.
› In addition to ensuring rapid response, ARTECHE developed a continuous service improvement plan, which sustains an extensive training program with courses, publications, conferences, etc.
› ARTECHE’s focus on service, with a broad experience leading us to be an active participant in the electrical organizations such as: IEC, IEEE, CIGRE, CIRED, ASINEL, etc.
› ARTECHE has production facilities in four continents (North America, South America, Europe, Asia and Australia) and more than 70 technical/commercial offices. Thus ARTECHE provides effective responses to the requirements of any customer and situation, based on the global knowledge acquired. AAAARRRRTTTTEEEECCCCHHHHEEEE hhhhaass tttthhhhee
ttteecchhhnnoollloogggyyy aannddd ccaapppaabbbiiillliiitttiiieess oofff iiinnsstttrruummeennttt tttrraannssfffoorrmmeerrss.. TTTThhhhuuusss wwweee pppprrrooovvviiiiddddeee tttthhhheee bbbbeeessstttt ssoollluutttiiioonn aavvaaiiilllaabbblllee iiinn ttthhhee mmaarrkkkeett.
www.arteche.com ©ARTECHE
ARTECHE_CT_trfLV_ENVersion: A1