Instrument Transformers Low Voltage Current Transformers 600 Volt Class - Indoor Type Low Voltage Potential Transformers 600 Volt Class - Indoor Type Bushing Current Transformers 600 Volt Class Medium Voltage Current & Voltage Transformers 5kV to 38kV - Indoor type Instrument Transformers 731 736 737 735 729 g Multilin Digital Energy

Instrument Transformers - GE Grid Solutions · Instrument Transformers. Low Voltage Current Transformers . 600 Volt Class - Indoor Type. Low Voltage Potential Transformers . 600 Volt

  • Upload
    others

  • View
    49

  • Download
    2

Embed Size (px)

Citation preview

Inst

rum

ent T

rans

form

ers

Low Voltage Current Transformers 600 Volt Class - Indoor Type

Low Voltage Potential Transformers 600 Volt Class - Indoor Type

Bushing Current Transformers 600 Volt Class

Medium Voltage Current & Voltage Transformers 5kV to 38kV - Indoor type

Instrument Transformers

731

736

737

735

729g MultilinDigital Energy

Inst

rum

ent T

rans

form

ers

738

739

739

Instrument Transformers

Control Power Transformers5kV to 38kV - Indoor type

Current Transducers600 Volt Class

IEC - Rated Instrument Transformers (Indoor/Outdoor)

730 g MultilinDigital Energy

731

Inst

rum

ent T

rans

form

ers

www.GEDigitalEnergy.com

Applications• Energy management• Load surveys• Sub metering

Features• Window sizes from 0.75 x 0.75 to 12 x 30 inches• Ratios from 100:5A to 10,000:5A • Voltage output available • Weather proof model available• UL Recognized and CSA Approved

Applications• Three phase metering and motor overload protection

Features• Over 50 models available • Saves space and reduces installation time• Zero sequence core in the same package available for

most models• Ratios from 50:5A to 4000:5A• UL Recognized and CSA Approved

Applications• Designed for use in the secondary of main current transformers

to change the ratio for metering or relaying applications

Features• Several models available• Wound primary up to 50A • IEEE or IEC metering and relay class• Summation CT’s up to six secondaries• UL Recognized and CSA Approved

Auxiliary Current Transformers

Three Phase Current Transformers

LOw VOLTAGE CuRREnT TRAnsFORMERs

split Core Current Transformers

Instrument Transformers

732

Inst

rum

ent T

rans

form

ers

www.GEDigitalEnergy.com

Applications• Designed for specific mount applications in low and medium

voltage switchgear

Features• Wide range of window sizes• Ratios 50:5A to 6000:5A • 1 Amp secondaries are available• Multi ratios model available• Designed to meet IEEE C57. 13 • UL listed and CSA Approved

Applications• For use with ammeters in panelboards, control panels

and engine generators

Features• Wide range of window sizes• Ratios 50:5A to 2000:5A • 1 Amp secondaries are available• Supplied with leads or terminals• Integral feet or mounting brackets available• UL Listed and CSA Approved

Current Transformers

Applications• For metering and relaying applications in low voltage

switchboards, switchgear and motor control

Features• Wide range of window sizes• Ratios 50:5A to 6000:5A • 1 Amp secondaries are available• Supplied with leads or terminals• Multi ratios model available• Designed to meet IEEE C57. 13 or IEC 60044-1• UL listed and CSA Approved

Current Transformers

Current Transformers

Instrument Transformers

733

Inst

rum

ent T

rans

form

ers

www.GEDigitalEnergy.com

Applications• To sense zero sequence ground fault currents

Features• Window sizes up to 30x 10 inches are available• Ratios 50:5A and up• Special ratios and physical sizes built to customer specifications • UL Recognized and CSA Approved

Applications• For ammeters, wattmeters, and cross current compensation

applications

Features• Wide range of window sizes• Ratios 50:5A to 6000:5A• 1 Amp secondaries are available• Supplied with leads or terminals• Integral feet or mounting brackets available• UL Listed and CSA Approved

Applications• Designed to match the ground fault input of GE Multilin motor

protection relays

Features• Window sizes 3.75” , 5.75” or 8.13” • Ratio 50:0.025A 60 Hz• IEC versions also available • UL and CUL recognized

Current Transformers

Ground Fault sensors

Ground Fault sensors Type HGF

LOw VOLTAGE CuRREnT TRAnsFORMERs (COnT.)

Instrument Transformers

734

Inst

rum

ent T

rans

form

ers

www.GEDigitalEnergy.com

Applications• Designed for operation of meters and instruments• Utility metering large window

Features• Designed for outdoor service• Compression type terminals• Ratios from 200:5A to 4000:5A• Dual ratio models available• Engraved aluminum name plate• Meet ANSI C12 size and mounting

Applications• Designed for operation of meters and instruments• Utility metering small window

Features• Designed for outdoor service• Encapsulated in cast polyurethane resin• Compression type terminals• Ratios from 100:5A to 800:5A• Dual ratio models available• Engraved aluminum name plate• Meet ANSI C12 size and mounting

Applications• Designed for operation of meters and instruments• Utility metering• Mounts directly on busbars or padmount transformer spade

Features• Window sizes 3.46” x 4.16”• Ratios 200:5 to 4000:5• Meet ANSI C12 size and mounting

Current Transformers

Current Transformers

Current Transformers

Instrument Transformers

735

Inst

rum

ent T

rans

form

ers

www.GEDigitalEnergy.com

Applications• For single phase voltage measurement in AC power systems

Features• Resin cast moulded plastic cases • Integral fuses available on some models• Designed to meet IEEE C57.13• 50Hz design available• UL Recognized and CSA Approved

Applications• For three phase voltage measurement in AC power systems

Features• Resin cast moulded plastic cases • Integral fuses available on some models • Designed to meet IEEE C57.13 • 50Hz design available• UL Recognized and CSA Approved

Applications• Designed for indoor and outdoor service; suitable for operation

meters, instrument transformers, relays, and control devices.• Utility metering

Features• Housed in a resin filled plastic case • Compression type terminals • 50Hz design available• Transparent plastic terminals cover • Engraved aluminum nameplate• Designed to meet IEEE C57.13

Voltage Transformers

Voltage Transformers

JVA Voltage Transformers

LOw VOLTAGE POTEnTIAL TRAnsFORMERs

Instrument Transformers

736

Inst

rum

ent T

rans

form

ers

www.GEDigitalEnergy.com

Applications• For use over bushings of power transformers and dead

tank circuit breakers• For metering and relaying applications

Features• Indoor or outdoor service• 600V class to IEEE C57.13 or IEC 60044-1• Ratios 50:5 to 25000:5• Single and multi ratios available• Optional ground shield available

Applications• Designed to customers specifications for metering and

relaying applications• High voltage circuit breakers and power transformers

Features• 600V class to IEEE C57.13 - 1993• Single and multi ratio designs available• Leads or terminals available• Designs for use in oil are available

Applications• Designed for mounting and stacking over the bushings of

large generators • For metering and relaying applications

Features• Ratios up to 40,000:5A • 1 Amp secondaries and IEC design available• 600V class 50 or 60Hz • Shield winding available

Cast Resin unit

Taped unit

Board Mounted unit

BusHInG CuRREnT TRAnsFORMERs

Instrument Transformers

737

Inst

rum

ent T

rans

form

ers

www.GEDigitalEnergy.com

Applications• Indoor voltage transformers for metering and relaying

applications in AC power systems

Features• Vacuum cast polyurethane resin• Designed to meet IEEE C57.13 • 5kV to 34.5kV with BIL rating up to 200kV• UL Recognized and CSA Approved

Applications• Designed for outdoor service; suitable for operating

meters, instruments, relays and control devices.

Features• Designed for outdoor service • Hydrophobic Cycloaliphatic Epoxy insulation• Engraved aluminum name plate• Designed to meet C57.13• 15kV to 36.5kV with BIL ratings up to 200kV

Applications• Indoor current transformers for metering and relaying

applications in AC power systems

Features • Vacuum cast polyurethane resin • Designed to meet IEEE C57.13 • 5kV to 34.5kV with BIL rating up to 200kV• UL Recognized and CSA Approved

Applications• Designed for outdoor service; suitable for operating

meters, instruments, relays and control devices.

Features • Designed for outdoor service • Hydrophobic Cycloaliphatic Epoxy insulation• Ratios from 5:5A to 1200:5A, 50/60Hz• Dual ratio models available• Engraved aluminum name plate• Designed to meet C57.13• 15kV to 36.5kV with BIL ratings up to 200kV

Voltage Transformers

15-35kV Outdoor Voltage Transformers

Current Transformers

15-35kV Outdoor Current Transformers

MEDIuM VOLTAGE CuRREnT & VOLTAGE TRAnsFORMERs

Instrument Transformers

738

Inst

rum

ent T

rans

form

ers

www.GEDigitalEnergy.com

Applications• To provide control power in medium voltage switchgear

Features• Vacuum cast primary coil using epoxy resin• Single phase rating from 5 kVA to 37.5 kVA• Voltage rating 5 to 15 kV and BIL rating to 95 kV BIL

Applications• To provide control power in medium voltage switchgear• Generator neutral grounding transformer

Features • Vacuum cast primary and secondary coils using epoxy resin• Single phase rating from 25 kVA to 75 kVA• Voltage rating 5 to 34.5kV and BIL rating to 150 kV BIL

Applications• To provide control power in medium voltage switchgear

Features• Vacuum cast using epoxy resin• Three phase rating from 15 kVA to 150 kVA• Voltage rating 5 to 34.5kV and BIL rating to 150 kV BIL• Horizontal and vertical mounting available in some models

single Phase Cast Coil Transformers

single Phase Cast Coil Transformers

Three Phase Cast Coil Transformers

COnTROL POwER TRAnsFORMERs

Applications• Process control• Industrial measurement

Features• Models available for 5 to 600 primary AC current• Output 4-20 mA dc• UL recognized

CuRREnT TRAnsDuCERs

Instrument Transformers

739

Inst

rum

ent T

rans

form

ers

www.GEDigitalEnergy.com 0926-v7

• Viewcatalogsheets

• ReviewapplicationsNotesandsupportdocuments

• Buyaninstrumenttransformeronline

• Viewtheproductbrochures

Visit www.GEMultilin.com/ITI to:

Applications• Suitable for measuring applications in AC power systems

Features• Available for indoor applications • DIN rail mounting • Designed to meet IEC 60044-1• 720V rated

Applications• Suitable for measuring and protection applications in

AC power systems

Features • Available for indoor or outdoor applications • Vacuum cast in epoxy resin• Designed to meet IEC 60044-1• Available from 12 to 36 kV • Multiple core designs available for measuring and

protection in one package

Applications• Suitable for measuring and protection applications in AC power systems

Features• Available for indoor or outdoor applications • Vacuum cast in epoxy resin• Designed to meet IEC 60044-2• Available from 12 to 36 kV• Rated Voltage Factor: 1.2/1.9 (Continuous/8 hours)

Current Transformers (Low Voltage)

Current Transformers (Medium Voltage)

Voltage Transformers (Medium Voltage)

IEC - RATED InsTRuMEnT TRAnsFORMERs

Instrument Transformers