21
Instrument

Instrument - KNP - Korea Nuclear Partnersknp-korea.com/pdf/I_C.pdf · Inside Memory: Mobile DDR 256MB Power Supply: AC/DC, PoE : Power supply through LAN cable ... CPU module, dualization

  • Upload
    donga

  • View
    217

  • Download
    1

Embed Size (px)

Citation preview

51

Instrument

52

Certification ISO9001 ISO14001

Characteristic System that systemizes the vibration analysis technology & knowhow of power plant, grafts intelligent prediction analysis, detects the failure or problem of main facilities earlier to prevent a severe accident by monitoring the condition of turbine & main rotating devices in real time.

Main Customer KHNP Korea East-West Power Co., Ltd. ENEC

Product Specification Input Chanel: Analog input 8CH, Tacho 2CH, 1Rack=48CH Input Sensor: All kinds of sensors such as vibration sensor of non-contact displacement meter, velocity sensor and acceleration (ICP) sensor and current, pressure, temperature and so on.

Input Signal: voltage output sensor (AC, DC, AC+DC), current output sensor, velocity sensor

Technology Specification This is designed to enable to replace on online even though there is failure or defects. Online & offline diagnosis programs and handing manuals for failure checking and performance test are prepared so that it can give a help to operator's proper handling and checking of failure.All provided equipment is a product applied the best quality and up-to-date technology. All electronic parts have module structures having rich compatibility. All equipment has an application history. This system has a life and durability that endure continuous commercial operation more than 10 years, and can supply parts that require replacement from abrasion or deterioration and can support technical assistance. For HMI graphic, it is required to discuss in advance with a purchaser. It is possible to operate under the ambient temperature of -45℃~85℃ and humidity of 5% ~95%, which is the environmental conditions in a control room of power plant.

VMS (Vibration Monitoring System)

Alarm buffer: Raw Data before / after giving an alarm can be saved and transmitted.

Maximum Frequency: 25,600Hz: Diagnosis of high frequency such as chattering of low speed roll and machine tool and fluid vibration.(Noise analysis function : audio frequency range)

Trigger : Start Trigger : To start measurement after getting a trigger signal at the special time.

External SD Memory: When an alarm rings, the data before and after the alarm can be saved automatically. => To increase convenience of Data analysis

Inside Memory: Mobile DDR 256MB Power Supply: AC/DC, PoE : Power supply through LAN cable (construction cost save: no need of separate power work)

Test, Inspection: earthquake-proof, environment-resistance,shock-resistance, susceptibility test

Input voltage: maximum ±10V DC measurement: 0.1Hz LP Filter(-3dB) AC measurement: 0.1Hz HP Filter(-3dB) Frequency Resolution: Max. 25,600 Lines DO module: 16point (Relay Dry Contact) Signal handling type: Digital Signal Processing To Host Interface: Ethernet Max. 10/100Mbps A/D Resolution: 24bit Dual Power: AC100~240V 2.5A CPU: OMAP-L138 (ARM9DHK DSP dual core) Storage:: Manual &Automatic Interval of data collection: 0.1 sec Sound Recording: Realization of actual noise by transforming the vibration waveform to the sound wave within the audible frequency range-> Sensible diagnosis is possible.

Rec.Output: 40CH Rec. Output (4~2mA)

Korea Nuclear Partners

53

CMS (Condition Monitoring System)

Characteristic System composed so that preventive maintenance linked with production schedule as well as the failure prevention of facilities can be made by evaluating, controlling the condition of industrial machine through monitoring.

Main Customer Kolon Hankook Tire Nexen Tire Hyundai Motors POSCO SNNC KORAIL Doosan Infracore Kia Motors Hyundai Mobis Kia China Hankook Hungary Samsung SDI

OPERASYSTEM-1400

Characteristic As a distribution control system for nuclear power plant which was successful in localizing for the first time domestically in 2010, this product is DCS platform developed for the purpose of applying to MMIS non-nuclear series instrumentation control system of APR-1400 type nuclear power plant. Currently, it was delivered to new reactor 1,2 at Ulchin MMIS and will be delivered to new reactor 5,6 at Kori by November, 2017. Application series are as follows:- Power Control System series- Plant Control System series- NSSS(Nuclear Steam Supply System Control System) series- Main Feed Water Control System series- Diversity Protection System series

Main Customer KHNP Jordan

Certification ISO 9001 KEPIC-EN

Technology Specification<Features of distribution control system for nuclear power plant> Reliability and Stability

- To secure reliabillity by dualization of control unit, dualization of control CPU module, dualization of I/O interface, dualization of communication network, dualization of power.

- Real time monitoring through self-diagnosis Deterministic communication network structure

- Guaranteed dispersion control method that divides into control communication network and information communication network.

- To secure deterministic response time by transmitting only real-time control data based on the status through a control communication network.

- The information communication network separates and transmits non-real time and event data.

Open architecture based on the industry standard- To support International Standard IEC 61131-3 programming language

and SAMA block format for controlling nuclear power plant- To adopt International Standard Ethernet, MODBUS, HART interface Convenient diagnosis and maintenance

- Online/Offline diagnosis and hot-swap functions enables to change modules during operation.

Product Specification Input signal: Voltage output sensor, current output sensor, velocity sensor Frequency range: DC~25,600Hz Trigger :Start Trigger Power Supply: AC/DC Test, Inspection: earthquake-proof, environment-resistance, shock-resistance, susceptibility test

Input voltage : maximum ±10V Frequency :Max. 25,600 Lines DO Module: 16 point (Relay Dry Contact) Signal handling method: Digital Signal Processing Host Interface: Ethernet (Max. 100 Mbps) A/D Resolution: 24 bit Dual Power: AC 100~240V, 1A

Certification ISO9001 ISO14001

Instrument

54

- Creating Spatial Analysis Contour over the Interested Area using Data from Mobile Survey

Real-time Monitoring and Integrated Management over the Local Discovery of Radiation

- Display Recent Measurement of P-ERMS & Mobile Survey, and Virtual Dose for Training

- Display Nuclide Counting Rate on Analysis of NaI(Tl) Spectrum Collection - Display History Trend Chart of Virtual Dose for Training and Measurement

of Mobile Survey - Display History Trend Chart of Counting Rate per each Nuclide- Display History Trend Chart of P-ERMS Measurement Dose Display information based on the Electronic Map - Auto Update of Instrument Location, Display of Measuring and Analysis

Data on a map - Display the Spatial Analysis Contour on a map against ERMS, P-ERMS

measured value- Register KMZ (analysis of mobile survey) and mark on an Electronic Map - When Selecting Point from an Electronic Map, Mark the Road View around

the Relevant Site with Charts and Values of Spectrum. Nuclide and Counting Rate

Reproduce and Mark the Process of Mobile Survey by selecting the Previous Survey Result

Adjust and Control Extend/Reduce/Move and and View Angle on an Electronic Map

Indicate the Centered Location and Information of Surrounding Faicilities using Index Map which is automatically Interlocking with the Electronic Map

Selective Control over the Visibiity according to the Information Indicated on the Electroninc Map.

Certification SIREN Lisence Contract (KINS-RADSEARCH) SIREN(System for ldentifying identifying Radiation in Environments Nationwide) Program Register

Mobile Radiation Survey Application (EMERGLE) Program Register

Characteristic Expert System to Manage and Analyze Data from a Fixed Station on the basis of the Electronic Map with Data from Mobile Tracking Station such as Space/Vehicle/Marine/Backpack. Incident Management in case of Emergency and Speedy Decision-Making will be provided.- Provide Incident Response Training Environment under the

scenario setting of Virtual accidents as well as Managing Real accidents

- Provide Cooperative System for Real-Time Sharing of collected Data on Emergency/Training with Interagency

Main Customer Korea Institute of Nuclear Safety, Korea Hydro & Nuclear Power Co., Ltd. Kori Nuclear Power Site Korea Hydro & Nuclear Power Co., Ltd. Hanbit Nuclear Power Site Korea Hydro & Nuclear Power Co., Ltd. Hanul Nuclear Power Site

Technology SpecificationCustomizing based on the SIREN program. Plans for Training and Radiation Field Survey

- Establishing detailed plans for Field Survey and Checking existing Information.

- Mark the 16 points of the Compass and set Interested Survey Area around the Field Survey Point.

- Mobile survey, Registered P-ERMS System, Registered the change and Input Location, Modify and refer the modification,

Data Acquisition and Analysis over the Mobile Survey of Radiation- DB Storing and Managing after collecting a large number of Mobile

Surveyed Data- Auto Management and Error Check over the collected location

Information - Real-time Calculation of Counting Rate per each Nuclide using registered

Nuclide and ROI information against Spectrum Information- Creating Spatial Analysis Contour using ERMS, P-ERMS information.

Environmental Radiation Comprehensive Monitoring System (SIREN/ERIMS)

Korea Nuclear Partners

55

ERMS Intergrated Management System

Characteristic Check Ent i re ERM Operat ion Status by the Intergrated Environmental Radiation Management System- Map based ERMS Measurement, Display States of Instrument Operation by Symbol or Value- Remote Management and Detailed Information Check to understand quickly Emergency/Damage - Print Reports on Statistical Information, Value and Time-series Charts on Hourly, Daily, Weekly, Monthly, Yearly basis.

Product Specification Window OS Environment Based Web System

- TCP/IP, M2M Based Data Acquisition through Various Wire/Wirelss Communication

Certification ISIREN Lisence Contractor(KINS-RADSEARCH) SIREN(System for ldentifying Radiation in Environments Nationwide) Program Regiser, Mobile Radiation Survey Application Program(EMERGLE) Register

Technology SpecificationInformation Setting Required for Program Operation such as CDMA Modem Information, Communication Port, DB Access Information Support TCP/IP and M2M Communications Change Environmet Setting or Remote Control for ERMS Instrument

- LCU Restart, Change Data Aquisition Period - NaI(Tl) High Voltage, Change Energy Calibration Factor and Gain Value Change Inquiry for Environment Settings of P-ERMS Instrument

- Change Calibration Factor- Add/Control P-ERMS Instrument Transmit and Receive ERMS Local Measurement Data

- Information on HPIC Dose Rate and States of Instrument- NaI(Tl) Dose Rate, Gamma Spectrum and Information on states of

Instrument - States of Instrument such as UPS, Air Sampler, Rain Detector and Surge

Protector etc. Transmit and Receive P-ERMS Local Measurement Data

- GM-Tube Dose Rate and Information on States of Instruement- Installation Location(GPS coordinates)

Main Customer Korea Institue of Nuclear Safety, Korea Hydro & Nuclear Power Co., Ltd. Kori Nuclear Power Site Korea Hydro & Nuclear Power Co., Ltd. Hanbit Nuclear Power Site Korea Hydro & Nuclear Power Co., Ltd. Hanwol Nuclear Power Site

When Wire Communication Failure Occurs, it Automatically change to Wireless Communication. When there is Data Loss for some period of t ime due to the Communication Failure or LCU Problems, it Automatically Requests Data Backup Since Recent Data Aquisition Time

When Replacing ERMS to P-ERMS due to Malfunction, Save P-ERMS Data Aquisition on the point of Substitue Installation and Mark it on a Map

Data Analysis and Alarm Management- Real-time Auto Management upon Receiving ERMS Data- NaI(Tl) Spectru, Dose Rate and Calculate and Save the Counting Rate per

each Nuclide - Perform and Save Periodical Statistical Analysis on the Data Aquisition

and Analysis Result- Alarm Analysis and Sending SMS on the Result of Data Aquisition and

Analysis

Instrument

56

ERMS Local Control Unit(LCU)

Characteristic 365 days Non-Stop Operation working in a line with Radiation Meausrement Instrument, Data Aquisition and Storage on a second/minute basis.- Support Calibration, Operation and Managment of Measurement

Instrument- Using Nulide ROI information, Produce Real-time Statistical

Information over cps per each Nuclide.- Indicate the Interested ROI section on a Spectrum Chart. - Auto Renewal and Cumulative Display of Counting Rate for Time

Diffences of Gamma Spectrum with lines of 44 colors according to Relative Sizes.

Main Customer Korea Hydro & Nuclear Power Co., Ltd. Kori Nuclear Power Site Korea Hydro & Nuclear Power Co., Ltd. Hanbit Nuclear Power Site Korea Hydro & Nuclear Power Co., Ltd. Hanwol Nuclear Power Site

Technology Specification Control and Manage Instrements

- After Automatic Connection with HPIC Detector, Automatically Configure Data Aquisition Preparation.

- After Connecting to NaI(Tl) Detector, Automatically change the Communication Methods in Hi-Voltage Dual Connection upon Communication Problem with LCU

- Channel Shift Autocalibration through Automatic Adjustment over Hi-Voltage and Gain depending on the K-40 Channel shift of Gamma Spectrum from NaI(Tl) Detector.

- Wireless Communication Modem(CDMA) Auto Port Connection and Auto Visual Synchronization

- Auto-Configuration for Data Aquisition after Automatically Connecting Air Collector,UPS and other devices

- Connect Air-Sampler, UPS and Dosimeter to Auto ports and Transmit Data

- Automatically Implement Periodic Visual Synchronization between LCU and Instruments

Data Aquisition and Management

Product Specification ○ Controller

- ADVANTECH ARK-3500 - Processor① 4Th Generation Intel CoreTM i7 : 2.3GHz(Quad Core)② L3 Cache : 6MB- Memory : DDR3L 1600MHz, over 8GB - Graphics① Intel QM77 Integrated GFX Gen7② Resolution : 1920 x 1200 @ 60Hz- Interface① USB : 6 Port ② RS-232 : 8 Port ③ LAN : 2 Port④ DIO : More than 1 Port - SSD : 512GB, 2EA(Dual)- Others① Compact Fanless Box PC Type② Built in Watchdog timer③ Operating Temperature -20℃ ~ 60℃ @ 5 ~ 85% RH④ Storage Temperature -40℃ ~ 85℃ (-40℉ ~ 185℉)⑤ Shock Protection Operating, IEC 60068-2-27⑥ Vibration Protection Operating, IEC 60068-2-64⑦ Surge protector Installation⑧ Power Noise Filter Installation⑨ Filter Fan Installation for Interior Cooling⑩ 온도 컨트롤러 장착(2 Relay 방식, 디지털 온도 제어) 모니터 : 15.6 Wide(TFT LCD)

- 해상도 : 1920 x 1080- Display Colors : 262,144 color

- Store and Manage Data Aquisition considering Dose Rate and States of Instrument through periodic communication with HPIC.

- When operating Programs, Automatically check the chance of HPIC Data Aquisition Failure and Perform Automated Data(not-collected) Recovery

- By Communicating with HPIC, Configuration Information can be Collected, Checked and Changed

Certification SIREN Lisence Contractor (KINS-RADSEARCH) SIREN(System for ldentifying Radiation in Environments

Nationwide) Program Register Mobile Radiation Survey Application Program(EMERGLE) Register

Korea Nuclear Partners

57

the Level of Management. - Display Longitute, Latitude and Altitude of Measuring Location, no. of Receiving

Satelites and Speed per Directions and Auto-Renewal every Aquisition Cycle- Adjust map scale and move the map with 4 way directions - Mobile Survey Monitoring using entire Maps Data Management of Gamma Spectrum

- Real-time Display of the whole Counting rate obtained from Detector and Auto-Renewal every Aquisition and Display Cycle.

- Adjust Counting Rates of Gamma Spectrum obtained from NaI(Tl) Detector to Linear or Log Scale, and Mark them on a Chart and Renew Automatically every Aquisition Cycle.

- Indicate the Interested Nuclide ROI Section on a Chart- Mark the Expanded Spectrum around the Interested Channels on a Chart Real-time Analysis

- Real-time Display of Conversed Dose Rate- Using Nuclide ROI Information, Produce the Statistical Information over cps per

each Nuclide in real-time. - Support Training Mode and Display the Dose Rate and Trend chart of Nuclide

cps over Time- Recieve the Disaster Drill Scenario and Process them. - Generate Data for Training composed with Real Measurement Value by

calculating the Hypothetical Accident Dose Rate of Measuring Point with Disaster Drill Scenario and GPS Loation Information.

Data Transmit/Receive - Support TCP/IP Communication for a Real Time Transmission- Send Data Pakets with the Latest Data Aquisition/ Analysis - Automatically Transmit the undelivered Data and Reconnect when

Communication Problem Occurs.

Characteristic Moving and Working Togather with Various sorts of Radiation Measurement Instruments, Provide Location based Radiation Data Aquisition and Analysis Provide Training Mode in a line with Intergrated Monitoring System of Environmental Radiation Data Management of Location and Period using Maps.Remote Transmission of Data into the Intergrated Monitoring System of Environmental Radiation

Main Customer Moving and Working Togather with Various sorts of Radiation Measurement Instruments, Provide Location based Radiation Data Aquisition and Analysis

Provide Training Mode in a line with Intergrated Monitoring System of Environmental Radiation Data Management of Location and Period using Maps.Remote Transmission of Data into the Intergrated Monitoring System of Environmental Radiation

Technology Specification Control the Detector and Instruments

- Perform Automatic Measurement and Hardware Control by interlocking with Dectector

- Process Live Time, Number of Counts per Channel through Communicating with NaI(TI) every collecting period, Automatic Linkage with NaI(ti) Dectector

- Automatic linkage with GPS Receiver, Collect and Procees the GPS information through communicating with GPS

Receiver every collecting period Real-time Transmission of Mobile Survey Data to EIRMS Server Calibrate Energy of NaI(Tl) Dectector

- Perform Peak Analysis automatically against Gamma Spectrum , generate Peak Channel and Indicate the Peak location on Spectrum Chart.

- Designate Calibrated Dose or Natural Nuclide Information after choosing Peak Location marked on Spectrum Chart.

- Automatic Calculation and Application System on Energy Calibration Factor with Quadratic Function Using the least-spuares method over the Designated Peak Channels and Nuclide Information. Location-based Data Management using Maps.

After Registering Image map, Data obtained from NaI(Tl) Detector is being mapped to the map in Real-Time, and Display them as Symbols depending on

Radiation Space/Vehicle/Backpack Mobile Tracking System

Product Specification NaI(Tl) Detector(3”X3”) and Signal Conditioning Device(digiBASE) Control PC GPS Receiver Portable Battery Package LET Modem

Certification SIREN Lisence Contract (KINS-RADSEARCH) SIREN(System for ldentifying identifying Radiation in Environments Nationwide) Program Register, Mobile Radiation Survey Application (EMERGLE) Program Register

Instrument

58

Characteristic This consists of LOOP part to receive data from a radiation monitor, SERVER part to manage the data, and terminal and other peripherals to control and operate radiation. Radiation monitor is composed of duplex system using RS485, and SERVER and OIU are composed of a duplex system using ETHENET communication.

Main Customer Gori Nuclear Power Plant #1

Product Specification Duplex System of the Server Computer, Long Term Data Storage, RS485 and Network Communication, RMS OIU, Digital 8 Channels and Analog 8 Output Channels, Monitoring the State of Facilities, Database Management, Real-time Communication of Radiation Monitor, System Management, Alarm Control Process, Network Control and Management, System Security.

Technology Specification ASTM A36 : Structural Steel NEMA ICS-6 : Enclosures for industrial Control Any Systems NEMA PMC 33.1 : Electromagnetic Susceptibility of Process Control Instrumentation

SSPC SP-8 : Steel Structures Painting

Radiation Monitoring SystemComputer and Software (RSK-100)

Radiation Monitoring System (CMK-100)

Characteristic Real-time Measuring and Monitoring Gas Filled Radiation to measure and monitor the level of radiation contamination in air. Detector. Measure the Particulate, Iodine with Particulate or Noble Gas at the same time.

Main Customer Gori Nuclear Power Plant #1

Product Specification Power : 120 VAC, 50/60 Hz, 1 phase Radiation Detector : Scintillation Type Sample Flow : 1 ~ 4 SCFM Minimum Detection on Concentration

- 1 X 10-7 Bq/cc (Particle)- 3 X 10-8 Bq/cc (Iodine)- 3 X 10-4 Bq/cc (Noble Gas) Detection Efficiency

- 2 X 108 cpm/Bq/cc (Particle)- 6 X 108 cpm/Bq/cc (Iodine)- 8 X 104 cpm/Bq/cc (Noble Gas)

Technology Specification Gori Nuclear Power Plant #1 +E4

Korea Nuclear Partners

59

LPMS (Loose Part Monitoring System)

Characteristic LPMS is one of the NIMS(Structural Integrity Monitoring and Diagnosis of Nuclear Reactor System). The shock sensitive accelerometer sensor attaced on the external wall of steam generator and nuclear reactor drifts around with water coolant in a system estimating the location, weight and the risk of loose parts which can create critical damage to a system. By providing information of the risk of internal damage it consolidates structural integrity of nuclear reactor system.

Main Customer Kori #1,2,3,4,/ Hanbit #1,2/ Hanul #1,2

Certification KEPIC-EN Certificate

(Control Class 1E, Alarm, Manufacture Monitoring System) ISO Certificate (ISO 9001:2008)

Technology Specification Input Accelerometer signal :

- 16ch (Default), Max. 32ch (Using two MCU) DSP Technology : TMS320C6747 32Bit 300MHz,100KHz Sampling and digital filter

Analysis Software : Trend Display, System diagnostics, Provide various Wave From Analysis Methods

Certification Supp ly Spare Equ ipment (RADIATION MONITORING EQUIPMENT) (407, Q)

Device Repair(Power Supply(Q), Electronic Card/Module(Q), Radiation Monitoring System(A))

Comprehensive Inspection and Maintenance Service for the Radiation Monitoring System in Office(Yong-21, Q)

Maintenance Service for Measuring and Control Instrument in Nuclear Power Plants (Yong-31, Q)

Comprehensive Check on the Electronic Circuit Board (ICT) Maintenance Service (Yong-63, Q)

Characteristic Area Radiation Detector to Measure and Monitor Space Radiation Dose in Atmosphere. It Measures the Dose Consecutively and Display the Measured Value on a Local Controller as well as Transmitting the Measured Value from All the Detectors to the Operator's Computer through RS-485 Communication.

Main Customer Gori Nuclear Power Plant #1

Product Specification Radiation Detector : GM Tube Type Detector Dynamic Range

- 1 X 10-3 ~ 1 X 103 mR/h Energy Response : 50 keV ~ 3 MeV Internal Installation of Source Detector Gamma Sensitivity : 2 cps/mR/hr (co-60) Detector Dead Time : 45 microseconds

Technology Specification ANSI N42.3 : Test Procedures for Geiger-Muller Counters ANSI N42.5 : Bases for GM Counter Tubes ASTM A36 : Structural Steel NEMA ICS-6 : Enclosures for industrial Control Any Systems

Radiation Monitoring SystemComputer and Software (RSK-100)

Instrument

60

SIS : Signal Isolated Splitter

Characteristic I.Splitter is a product to change and distribute signal (mA, V, Contact) after electrical segregation by receiving various signal (mA, V, mV, Pt100, Contact) from site- Quality class : Q- Eletric Power class : CLASS 1E

Main Customer New Hanul #1,2 Auxiliary Process Cabinet(APC) (Doosan Heavy

Industries & Construction)

Certification KEPIC-EN Certificate (Control Class 1E, Alarm, Manufacture Monitoring System)

ISO Certificate (ISO 9001:2008)

Technology Specification Input Power Standard : 24VDC ± 2.4VDC

- Control over Gain and Offset - Voltage, Current Signal Accuracy (full Scale) Room Temperature 0℃ ~ 40℃ : 0.1% Room Temperature 40℃ ~ 70℃ : 0.2%

- Size : 95.4mm X 180.4mm X 85mm- DIN Rail Mounting (W35mm)

FPGA-Based DPSDPS (Diverse Protection System)

Characteristic The Diverse Protection System is to stop nuclear reactor and turbine to operate auxiliary feedwater system to protect power plant safely when the defunctionalization of the protection system of the power plant. This is a Core Equipment requiring high level of Reliability and outstanding stability.

* Woori Technology designed, manufactured and distributed DPS with FPGA new technology application for the first time in Korea.

Main Customer Habit #3,4,5,6 / Hanul #3,4,5,6

Certification KEPIC-EN Certificate (Control Class 1E, Alarm, Manufacture Monitoring System)

ISO Certificate (ISO 9001:2008)

Technology Specification FPGA system implementation without CPU and OS

- Possibility of eliminating the common cause of disorder for PLC based failities

- Digital equipment implementation only using hardware- Outstanding stability and creditworthy with simple structure in

comparison with Micro Processor - Cyber security Enhanced- Simple Structure with easy application to PPS

Korea Nuclear Partners

61

SMS (Seismic Monitoring System)

Characteristic A system to analyze earthquake wave detected by high speed data scanning from accelerometer sensor to provide alarm in the situation of set value(0.01g) excess to the main control section, and through earthquake data analysis, proceeds stability evaluation and as well as estimate operating basis earthquake(OBE) and allows operator to analyze earthquake information even after the earthquake

Main Customer Kori #1,2,3/ Hanbit #1,3,5 / Hanul #1,3

Certification KEPIC-EN Certificate

(Control Class 1E, Alarm, Manufacture Monitoring System) ISO Certificate (ISO 9001:2008)

Technology Specification Maximize Reliability, Implemented on Embedded System,

- Save in Flash Memory, VMEbus Structure- Input Seismic Sensor signal : 8ch - DSP : TMS320C6747 32Bit 300MHz, - 100KHz Simultaneous Sampling and Real-time Digital Filtering - Provide various Wave Form Analysis Methods – Frequency

Alanysis Algorithm, - Response Spectrum Analysis Algorithm, CAV Discrimination

Algorithm

ASTS (Automatic Seismic Trip System)

Characteristic This system is desinged to take follow-up measures after Fukushima crisis to perform Trip when earthquake occurs exceeding the set value after earthquake Analyze Response Spectrum and CAV

Main Customer Jordan Research and Training Reactor

Certification KEPIC-EN Certificate

(Control Class 1E, Alarm, Manufacture Monitoring System) ISO Certificate (ISO 9001:2008)

Technology Specification Seismic Seismic Data Acquisition

- Input Range : -2.625V ~ 2.625V- Resolution : 16bit- Sample Rate : 500Hz- Input Point : X, Y, Z signal Seismic Data Process

- 12Hz LPF, 50Hz or 60Hz LPF - Filter Order : 12th Accuracy : 0.1% over full scale Calibration Function

Instrument

62

LEVEL GAUGE & ORIFICE ASS’Y

Characteristic 1. Observe and gauge the internal water level of VESSEL, TANK, BOILER DRUM etc. 2. Install in PIPE LINE to measure flux

Main Customer KHNP

Product Specification ASME MFC-3M ISO 5167

Certification ASME STAMP (U, PP, S) CE (PED) ATEX

Technology Specification ASME MFC-3M ISO 5167

SIGHT GLASS, ROTAMETER, TURBINE FLOW METER

Characteristic Installed in PIPE LINE to gauge flux

Main Customer KHNP

Product Specification ASME B16.5, B16.11 ISA RP31.1

Certification ASME STAMP (U, PP, S) CE (PED) ATEX

Technology Specification ASME B16.5, B16.11 ISA RP31.1

Korea Nuclear Partners

63

VENTURI TUBE, FLOW NOZZLE

Characteristic Installed in PIPE LINE to gauge flux

Main Customer KHNP

Product Specification ASME, MFC-3M ISO 5167 ISA 1932

Certification ASME STAMP (U, PP, S) CE (PED) ATEX

Technology Specification ASME, MFC-3M ISO 5167 ISA 1932

AVERAGING PITOT TUBE

Characteristic Installed in PIPE LINE to gauge flux

Main Customer KHNP

Product Specification ISO 5167 ASME

Certification ASME STAMP (U, PP, S) CE (PED) ATEX

Technology Specification ISO 5167 ASME

Instrument

64

SMC 7 Series

Characteristic Core which is a magnetic substance linked with float does a vertical movement in STEM of container. As float rises, CORE operates switch including magnet to act.

Main Customer KOMIPO KOEN ENEC Jordan JRTR

Product Specification Maximum Process Design Temperature: 400 ℃ Switch type: Micro Switch Last Specific Gravity : 0.6

Certification KEPIC EN / MN ISO 9001 ISO14002

Technology Specification It has a unique and stable mechanism applicable to the high temperature and high pressure without spring mechanism.

SDT-420

Characteristic It is a method that the change of force acting to displacer depending the change of liquid level occurs in Torque Tube as torsion stress and the angle of torsion changes to straight line motion through complicated mechanism to convey as pressure change to loadcell and outputs to DC 4~20mA.

Main Customer KHNP ENEC Jordan JRTR

Product Specification Measuring range:350 ~ 2000mm Maximum temperature /pressure : 450 ℃/ 100Kg/㎠ Output:4 ~ 20mA DC

Certification KEPIC EN / MN ISO 9001 ISO14001

Technology Specification It enables to control on remote through HART communication signal with two wire system without direct contact to a site. It is the first intelligent transmitter in Korea that is designed to use process control of diverse measuring information and history information through HART PROTOCOL.

Korea Nuclear Partners

65

GPS Time Synchronization Facility

Characteristic It is a facility so as to operate equipment with the exact time by providing and synchronizing en bloc the time to all sort of servers, local equipment's and security equipment's from GPS.

Main Customer KHNP ENEC

Technology Specification Application of adapted an algorithm against GPS jamming

SIT Extensometer

Characteristic It is a precision instrument to measure the expansion and return of nuclear reactor building during the Site Integrity Test of containment building.

Main Customer KHNP ENEC

Technology Specification Accuracy : 0.5% Full Scale / 0.001"

Instrument

66

Characteristic ADR(Auto Dosimetry Reading) System, SPDR-9400 make Simple Access Possible using Barcode Scanner and TFT LCD without direct entering Job Number or Operator Information. By Using Korean with English along with GUI Implementation, It became User-Friendly, and Convenient and Various Operating Fuctions Enhanced System Management Performance.

Main Customer Korea Hydro & Nuclear Power Co., Ltd.(Kori,Wolsong,Hanul,Hanbit)

Korea Radioactive-waste Management Corporation

Product Specification Size : 290 x 410 x 325 mm Weight : 10kg (Battery and Clip Included) Operating Temperature : -10℃ ~ -60℃

Certification ISO 9001:2008 CE : SPD-9300(ADR) CE : SPDR-9400(ADR Reader)

Technology Specification Applied Specification : IEC 61526 10.4" LCD Display (Intuitive User GUI) Touch Screen RF Communication TLD Reading Management Item: Access Details / Dose / Dose Rate / Job Number / Operator Information etc.

DOSIMETER READER (SPDR-9400)

Characteristic A precise radiation measurement instrument to systematically manage radiation exposure by providing various information to exposure management system through IR or RF communications as well as displaying the information of radiation dosage in real time

Main Customer Korea Hydro & Nuclear Power Co., Ltd. Korea Radioactive Waste Agency etc.

Product Specification Size : 79.5 × 48 × 20 mm Weight : 51 g (Battery and Clip Included)

Certification ISO 9001:2008 CE : SPD-9300(ADR) CE : SPDR-9400(ADR Reader)

Technology Specification Applied Specification : IEC 61526 Detector: PIN DIODE Measuring Range: Dose : 0.1 uSv to 10 Sv Dose rate : 0.1 uSv/h to 1 Sv/h

DOSIMETER (SPD-9300)

Korea Nuclear Partners

67

Main Customer Korea Inpection Co., Ltd. Daegu Fire Station

Product Specification Size : 150 × 90 × 40 mm Weight : 420 g (Battery Included)

Certification ISO 9001:2008 CE : SPD-9300(ADR) CE : SPDR-9400(ADR Reader)

Technology Specification Applied Specification : IEC 61000-4-2, 3, 8 Detector : GM Tube Measuring Range: Dose rate : 0.1 uSv/h to 1 mSv/h CPS/CPM : 0~99999 Detected Radiation: Alpha, Beta, X and Gamma ray

SURVEYMETER(SVM-8600) Monitoring Instrument on Damaged Fuel Bundle for Light-Water Reactor (DFI-200)

Characteristic Instrument to Detect Damaged Fuel Assembly and Measure the Level of Ration Dosage by Collecting Nuclear Fission Gas Discharged from the Fuel Assembly, If There is Damage in Fuel Assembly in Nuclear Reactor.

Main Customer KEPCO Nuclear Fuel Co., Ltd KEPCO Plant Service & Engineering Co., Ltd

Product Specification Measured Energy Area : 30 keV ~ 1 MeV Power : 120 VAC, 60 Hz Nuclide Detection : Xe-133, Kr-85 and etc. Flow : 100 L/min Detector : 3”x3” NaI(TI) Scintillation Detector Energy Resolution : 5% FWHN at Cs-137 MCA : 8192 Channel IN/OUT : AI(6 Channel), DO(4 Channel)

Certification Supply Spare Equipment(RADIATION MONITORING EQUIPMENT) (407, Q)

Device Repair(Power Supply(Q), Electronic Card/Module(Q), Radiation Monitoring System(A))

Comprehensive Inspection and Maintenance Service for the Radiation Monitoring System in Office(Yong-21, Q)

Maintenance Service for Measuring and Control Instrument in Nuclear Power Plants (Yong-31, Q)

Comprehensive Check on the Electronic Circuit Board (ICT) Maintenance Service (Yong-63, Q)

Technology Specification IAEA-TECDOC-602 ASTM A36 : Structural Steel NEMA ICS-6 : Enclosures for industrial Control Any Systems

Instrument

68

Characteristic It was impossible to diagnose the performance of hydraulic actuator of turbine valve, which is a main core device installed for controlling the amount of evaporator supplied to turbines of nuclear power generation and thermal power generation, without separation from the system. But the present hydraulic actuator is improved to be possible this diagnosis. This movable local tester makes the improvement of International creditworthiness to be possible through actual preventive maintenance, integrity evaluation, improvement of power quality, stable power production and reliability securement of maintenance for power generation by pre-performance test about this hydraulic actuator.

Main Customer Korea South Power Co., Ltd. Korea South East Power Co., Ltd.

Product Specification MR-PHST-10-150

Certification NEP

Technology Specification Local movable tester which is convenient to use at a site.

Movable Performance Tester for Hydraulic Actuator of Turbine Valve

Characteristic This is to Implement Physical Inventory Verification(PIV) on the Spent Nuclear Fuel from CANDU Nuclear Power Plant. It is Easy to Move, Install and User-Friendly along with High Accuracy and is being used in the International Atomic Energy Agency. (Registered in IAEA)

Main Customer Wolsong Nuclear Power Plant #1,2, Korea Institute of Nuclear Nonproliferation and Control (KINAC), International Atomic Energy Agency (IAEA)

Product Specification X-Y Axis Moving Unit, Z Axis Moving Unit, RS-232C Communication, Photo Multiplier Tube(PMT), Optical Fiber Cable 20m, AMP Gain Control, Current Display

Response Wavelength : 300 ~ 650 nm Measurement Range : 1 nA ~ 1 mA Lithium 7 Gamma Spectrometric Probe

Technology Specification Category A

Certification Supply Spare Equipment(RADIATION MONITORING EQUIPMENT) (407, Q)

Device Repair(Power Supply(Q), Electronic Card/Module(Q), Radiation Monitoring System(A))

Comprehensive Inspection and Maintenance Service for the Radiation Monitoring System in Office(Yong-21, Q)

Maintenance Service for Measuring and Control Instrument in Nuclear Power Plants (Yong-31, Q)

Comprehensive Check on the Electronic Circuit Board (ICT) Maintenance Service (Yong-63, Q)

Instrument to monitor the Spent Nuclear fuel for heavy water reactors (SFI-200)

Korea Nuclear Partners

69

Automatic Radiation Irradiator(IRSPD-9000)

Characteristic IRSPD-9000 System Monitors and Calibrates Radiation with Safety and Convenience using various Operating Softwares. It also Save, Manage and Analyze the Dose Rate and Accumulated Dose in Database through IR Communication by Monitoring Radiation of Dosimeter.Display Radioactive source decay on an Automatic Computing Software, Change the time of Auto Configuration depending on the Set Radiation Dosage, Calibrate Dose Conversion Automatically by Monitoring Dosimeter.

Main Customer Korea Hydro & Nuclear Power Co., Ltd.

Product Specification Size : 350 x 450 x 700 mm Weight : Approx. 680kg Operating Temperature : +5℃ ~ -40℃ Storage Temperature : -25℃ ~ +70℃

Certification ISO 9001:2008 CE : SPD-9300(ADR) CE : SPDR-9400(ADR Reader)

Technology Specification Source : Cs-137 10mCi(0.37 GBq)

Cs-137 20mCi(0.74 GBq) Cs-137 30mCi(1.11 GBq) Selection Mode Case Pb Shielding Thickness 50mm Auto Control on Filter Thickness and Radiation Dose Rate Filter

High level radiation : No Filter Medium level radiation : Filter Thickness 15mm Low level radiation : Filter Thickness 35mm (Filter Thickness 5mm or 10mm Selectable)

System for Managing Radiation Contamination on Vehicles (SVM-8600)

Characteristic VPM7000 System is specially Designed to Detect the Radiation Contaminated Material Loaded on Trucks. As the Basic VPM7000 System has Flexibility to Manage from one to four Detectors, it can Perform Dynamic Measurement depending on Vehicle Type, Freight and Changes in a Local Situation. SFT is equiped with System Customizing Ability to change the Size of Detector and Function of Control Unit according to the Needs from Fields.

Main Customer Korea Hydro & Nuclear Power Co., Ltd.

(Kori,Wolsong,Hanul,Hanbit), The Blue House

Certification ISO 9001:2008 CE : SPD-9300(ADR) CE : SPDR-9400(ADR Reader)

Technology Specification Detector : Plastic Scintillator(PVT) Rised on the condition of 0.2μSv/h BG

Sense 0.1μSv/h change (Within 0.3 seconds) Efficiency : Over 100,000 cps/ìSv/h (Cs-137)

Over 50,000 cps/ìSv/h (Co-60) Measuring Range : 30keV ~ 3Mev (Gamma Rays)

Instrument

70

In-core Nuclear Instrument

Steady State ConditionsTemperature : 10 - 49℃Pressure : AtmosphericRelative Humidity : 0 - 100%Radiation Level : 4x105Gy (4x107Rad). This value includes gamma and neutron radiation.

Characteristic It is installed in a nuclear reactor of Korean standard nuclear power plant. It is used to comprehend the power distribution of nuclear fuel in the nuclear reactor and to measure the nuclear fuel burnup by detecting neutron occurred during the nuclear fission reaction process of nuclear reactor.

Main Customer ENEC Product Specification

Model : WJ-ICI-Q Rhodium Detector x 5pcs Background Detector x 1pc K type Thermocouple x 2pcs Central Tube x 1 pc Filler Cable x 8 pcs

Certification ISO9001 OHSAS18001

Technology SpecificationSpecification Five(5) Rhodium Detectors Thermocouple Type : K type with ground junction Quality Class 1 Insulation Resistance shall be no less than 1x1011ohms.

- Environmental condition Steady State Conditionstemperature : 399℃; normal operating range ; 4.4℃ to 371℃.pressure :175 kgf/cm2a (2500psia);normal range :0 to 158 kgf/cm2a.

Core Exit ThermocoupleTemperature : up to 1260℃Pressure : 1.1 to 175 kgf/cm2aMedium : liquid, gas or two phase mixtureLocation : top of core

Transient Operating ConditionsOperating Fluctuations : The reactor coolant temperature will increase and decrease approximately 5.6℃ in one minute. At the same time, the coolant pressure may vary at a maximum of 7.03 kgf/cm2.These variations will occur a maximum of 150,000 times during the life of the in-core instrument assembly.

Operational Transient ConditionsTransient Conditions Number of OccurrencePlant heatup 75Plant cooldown 75RCS leak test 30Reactor trip 15

Korea Nuclear Partners

71

Remote Insulation Resistance Measurement System by High Voltage Electric Motor

Characteristic Spare Electric Motor Measures and Manages the Insulation Resistance Periodicaly to Secure System Reliability, However Repetitive Operation and Maintenance creates Gap at Tulip Contactor Leading to Increased Contact Resistance, Damage and bodily Injuries due to Manual Operation.This is to Measure Insulation Resistance Remotely to Predict Failure and Manage History to Secure Reliability, and Prevent Safety Accidents.

Main Customer KHNP

Certification 18002 for CE,KC,ISO15001,K-OH

Technology Specification Measurement Process

> Triple Protection System 1st Protection

Duplex Relay Operating Power Interlock Control 2nd Protection (H/W)

Duplex Relay Control depending on the states of CBContactless Sensing high voltage, Duplex Relay Control according to the measured level of Residual Voltage 3rd Protection

Transmit measurement order to S/W depending on the state of CB> Measuerment Process1. Check the resiual voltage and discharge2. Check the integrity of Duplex Relay3. Measure the insulation resistance, 2kV.5kV high voltage

Impression

Valve Leakage Monitoring System

Characteristic Using Hi sensitivity sound sensor, it monitors internal leakage of valve in real time and provide information of the early stage leakage caused by Foreign substances on the side of Valve body and seat, damages due to frequent valve opening and closing or crack between valve body and seat, defects on STEAM, PACKING, weld defect or fatigue crack.A system to Install sensors on a front and a rear part of valve using a clamp, analyze and estimate the leak by transmitting the sound signal to a measurement system through preamplifier.

Technology Specification Sensing PartField Signal → Preamplifier → (Signal Amplification) → Sensor Condition → (Filtering) → Analog/Digital Converter → (Digital) → DAQ

Analyzing PartExternal Input Signal → (AI/DI) → Input Output Unit → DAQ

Monitoring PartDAQ → External Input Signal Encode Field Signal → DBMS →(Field Signal/ External Input) → Analysis Software(Estimate Leak,Analyze Frequency) → DBMS → (Leakage information, AnalyzeFrequency) → VLMS Display S/W(Bar chart, Trend, Sperctrum)

Main Customer KHNP

Certification 18001 for CE,KC,ISO15001,K-OH

Instrument