4
Instructions for connecting the FL70 LED column The column can be powered from ~ 230V, carelessness when connecting or expanding with additional modules can be a risk of electric shock and pose a threat to life! Therefore, extreme caution should be exercised when connecting or configuring the device. Cables to be connected must not be live! 1. Connecting the wires to the base (column base). To facilitate connection, colorful wires come out of the base, corresponding to the colors of the module lights. Scheme: PNP or NPN control option („+” or „-„)

Instructions for connecting the FL70 LED column · 2020. 4. 6. · Instructions for connecting the FL70 LED column The column can be powered from ~ 230V, carelessness when connecting

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Instructions for connecting the FL70 LED column · 2020. 4. 6. · Instructions for connecting the FL70 LED column The column can be powered from ~ 230V, carelessness when connecting

Instructions for connecting the FL70 LED column

The column can be powered from ~ 230V, carelessness when connecting or expanding

with additional modules can be a risk of electric shock and pose a threat to life! Therefore,

extreme caution should be exercised when connecting or configuring the device. Cables to

be connected must not be live!

1. Connecting the wires to the base (column base). To facilitate connection, colorful wires come out of the base, corresponding to the colors of the module lights. Scheme: PNP or NPN control option („+” or „-„)

Page 2: Instructions for connecting the FL70 LED column · 2020. 4. 6. · Instructions for connecting the FL70 LED column The column can be powered from ~ 230V, carelessness when connecting

2. BUZZER mode setting (buzzer) H2-1,2,3; H1-1,2 “speaker” jumper.

Buzzer continuous tone - jumper on H2 - 1, 2 (first picture)

Buzzer intermittent tone - jumper on H2 – 2, 3 (second picture)

Buzzer pulsing tone - no jumper (third picture)

Buzzer timer - automatic shutdown after 120s - jumpers on H1 – 1, 2 (fourth picture)

Page 3: Instructions for connecting the FL70 LED column · 2020. 4. 6. · Instructions for connecting the FL70 LED column The column can be powered from ~ 230V, carelessness when connecting

3. Connecting the modules (colors). Each module is connected with a white tape, starting from the base and then the module with the next module ( in turn ).

Page 4: Instructions for connecting the FL70 LED column · 2020. 4. 6. · Instructions for connecting the FL70 LED column The column can be powered from ~ 230V, carelessness when connecting

4. Change of module lighting mode. The mode is selected

by changing the jumper.

Steady light - jumper on 1,2 (first picture)

Flashing light - jumper on 2,3 (second picture)

Rotating light - jumper on 1,2; 2,3 (third picture)

Pulsating light - no jumper (fourth picture)