INSTRUCTION MANUAL K210SDR 10 cuft. Solid Door Refrigerator

INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

INSTRUCTION MANUAL

K210SDR 10 cuft. Solid Door Refrigerator

Page 2: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

2 Last Revised 9/2017

Congratulations on your purchase! This refrigerator is specifically designed and built to

meet the rigorous demands of the life science, medical, clinical, pharmacy, and

laboratory industries. Each unit has been manufactured and shipped from ISO

9001:2008 facilities, is UL and cUL listed, and is compliant with EPA and SNAP HFC-

free refrigerant regulations. It is CDC and VFC-compliant for vaccine storage.

This manual can be downloaded from our website. Please contact the manufacturer

with any questions about the content herein.

Page 3: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

3 Last Revised 9/2017

SPECIFICATIONS

Temperature Range +2° to +8°C (+35.6° to +46.4°F)

Exterior Dimensions

H x W x D

59.43” x 23.62” x 22.15” (150.96cm x 60.0cm x 56.26cm)

Interior Volume 10 cu. ft. (283L)

Shelves 5 standard, 1 additional optional

Adjustable by 1” increments

Doors 1, right hand swing

Electrical 120V 60Hz

Shipping Weight 176lb (80kg)

Installation Minimum 2” clearance on all sides

INITIAL INSPECTION Accidents can happen, please be sure to perform a thorough inspection of your product

upon receipt. If the unit is damaged in any way, please refuse shipment and contact us

immediately. It is important to note any damages or shortages on the delivery receipt,

with driver acknowledgement, in order to help expedite the process. It is highly

recommended to have photographic evidence of these damages to assist with a swift

resolution.

WARNING

This label indicates important operating or maintenance instructions

which must be followed to avoid a situation which could result in death or

serious injury.

Page 4: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

4 Last Revised 9/2017

SAFETY INFORMATION To reduce the risk of death, electric shock, please follow basic precautions

including, but not limited to, the following:

Installation and maintenance should be performed by qualified technicians in

compliance with national, state, and local codes and regulations.

Do not use this appliance for any other purpose than its intended use. The

manufacturer is not responsible for damage or injury resulting from incorrect

usage.

Failure to properly install, operate, or maintain your product in accordance with

this manual will negatively impact safety, unit performance, and warranty.

Do not cover the front grille, unobstructed airflow is required to ensure adequate

ventilation.

All electrical work must be performed by qualified technicians.

Disconnect the unit from power prior to servicing or performing any maintenance.

Do not touch the unit, or any parts of it, with wet hands. Do not touch any

moving parts or hot surfaces. Do not probe any openings.

Do not use extension cords or multiple adaptors to supply power to the unit.

Only connect the unit to a properly grounded, three-prong wall outlet, do not

remove the ground prong from the product plug, do not use an adapter plug.

Never share the same circuit with other appliances, this unit requires an

independent power supply. Do not overload the power supply, always ensure

that the power supply is adequate for the electrical requirements specified on the

rating label. Do not use the unit if the power cord is damaged. The power cord

should never be altered or pinched. To disconnect the unit, pull on the plug, do

not jerk or pull on the cord.

Do not overload the power supply, always ensure that the power supply is

adequate for the electrical requirements specified on the rating label.

Do not run with damaged electrics.

Do not store or use combustible or flammable substances, such as aerosol cans

or gasoline, in or near the unit.

Do not use mechanical devices or other means to accelerate the defrosting

process.

Do not use electrical appliances inside the storage compartment of this unit.

Do not spray or splash water on the unit.

Do not modify the unit.

Properly supervise children around the unit. This unit is not intended for use by

children or adults with reduced physical, sensory, or mental capabilities or lack of

experience and knowledge.

Do not climb, stand, or hang on or in the unit.

Use caution when opening the door, avoid possible pinch points.

Page 5: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

5 Last Revised 9/2017

Do not block air inlets or outlets, keep the area around the unit clean and clear of

debris.

Do not overload the storage capacity of the product.

Do not load shelves with more than 50 pounds.

The maximum ambient temperature for this unit is +100°F (+38°C).

Component parts must be replaced with manufacturer original equipment parts.

Page 6: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

6 Last Revised 9/2017

INSTALLATION Installation should be performed by qualified technicians in compliance with

national, state, and local codes and regulations. Always work in pairs and

use care when lifting and positioning.

Remove the unit from all packaging and peel off any protective film.

Assembly Fit the shelf support clips (4 per shelf) onto the shelf pilasters, ensure that the clips for

each shelf are positioned at the same height (so the shelf does not tilt) and that they are

securely engaged on the pilaster.

Unwrap each shelf and position onto the clips.

If the unit has not been stored or moved in an upright position, let it stand

upright for a minimum of 24 hours prior to operation.

Power Supply The power supply cord is located at the bottom right hand side (as viewed from the

front), for ease of access, retrieve the cord prior to installing the unit in its final location.

The unit uses a three-prong grounded plug, which must be connected to a

properly grounded, three-prong wall outlet, do not remove the ground prong

from the product plug, do not use an adapter plug.

Never share the same circuit with other appliances, this unit requires an

independent power supply. Do not overload the power supply, always ensure

that the power supply is adequate for the electrical requirements specified on

the rating label.

Ensure the power cord is undamaged prior to use.

Location Avoid installing in direct sunlight, damp areas, or next to heat generating appliances.

This unit is intended for indoor use.

Allow adequate space for door opening.

Ensure the unit is positioned on a level surface so the door is able to shut and seal

correctly and to allow proper drainage from the evaporator tray (preventing any

Page 7: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

7 Last Revised 9/2017

overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling

legs to ensure proper operation.

Ventilation This unit requires ventilation on the sides, top, and rear, at a minimum of 2”

clearance. Failure to do so could result in harm to the unit, cause a fire, and

will invalidate the warranty.

Powering On Once plugged in the unit’s display will show the interior cabinet temperature, this is the

actual temperature recorded by the probes inside the unit. As the units cools to the set

point (factory set point is +4°C/39°F), the temperature displayed will lower accordingly.

If power is cut off, wait at least 10 minutes before plugging the unit in again to avoid

damaging the compressor.

Allow the unit to run for two hours prior to loading with any product.

Temperature Display/Controller Instructions for operating the controller are located in a later section of this manual,

under “MICROPROCESSOR CONTROLLER”

Page 8: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

8 Last Revised 9/2017

OPERATION The maximum ambient temperature for this unit is +100°F (+38°C).

The light will turn on when the door is open, and turn off while closed. To turn on the

light without opening the door, use the on/off switch located in the front.

The door can be locked using the key included with the unit.

Instructions for operating the controller are located in a later section of this manual,

under “MICROPROCESSOR CONTROLLER”

Do not block airflow from the vents or fan when loading product.

Do not overload the storage capacity of the product. Do not load shelves with

more than 50 pounds.

Page 9: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

9 Last Revised 9/2017

MICROPROCESSOR CONTROLLER

Page 10: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

10 Last Revised 9/2017

Page 11: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

11 Last Revised 9/2017

Page 12: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

12 Last Revised 9/2017

Page 13: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

13 Last Revised 9/2017

Page 14: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

14 Last Revised 9/2017

Page 15: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

15 Last Revised 9/2017

Page 16: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

16 Last Revised 9/2017

Page 17: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

17 Last Revised 9/2017

CLEANING AND MAINTENANCE Disconnect the unit from power prior to servicing or performing any

maintenance.

Do not use caustic or acidic cleaning agents or abrasive pads. Use only mild soap and

soft cloth.

Always wipe dry after cleaning.

Remove shelves and periodically clean to remove any debris or dust.

Periodically clean the door gasket to remove any debris or dust.

Filter The filter must be kept clean and free of dust at all times. At minimum, monthly

cleaning is necessary. Failure to keep the filter clean will damage the unit and

invalidate the warranty.

Pull the filter upwards to remove it from its location underneath the cabinet.

Use a vacuum cleaner with a brush attachment to remove dust.

Return the filter to its original location – do not operate the unit without the filter

installed.

Condenser The condenser must be kept clean and free of dust at all times. Failure to keep the

condenser clean will damage the unit and invalidate the warranty.

The condenser must never be cleaned with water. Never use a stiff brush or sharp

objects.

Page 18: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

18 Last Revised 9/2017

TROUBLESHOOTING Installation and maintenance should be performed by qualified technicians in

compliance with national, state, and local codes and regulations.

Problem Action

Unit will not start Check if the unit is plugged in correctly

Check if the power cord or plug is damaged

Confirm the unit is isolated on a power circuit

Please contact the seller if all of the above are in good working order.

Unit turns on, but the temperature is too high or too low.

Clean the filter

Clean the compressor

Move the unit away from direct sunlight

Move the unit away from a heat source

Ensure the front grille has unobstructed airflow across the entire surface area

Ensure door is shutting completely and that the door gasket is undamaged

Check temperature control for any incorrect settings

Check the ambient temperature (should not exceed 100°F/38°C

Check that the product load is not obstructing airflow inside the cabinet

Ensure the unit is not overloaded

Check fans to confirm all are working and not missing blades

Please contact the seller if all of the above are in good working order.

Unit is noisy Check that the unit is installed on a level surface

Page 19: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

19 Last Revised 9/2017

Check that the leveling legs are configured appropriately

Check for loose parts

Check fans to confirm all are working and not missing blades

Please contact the seller if all of the above have been checked.

Page 20: INSTRUCTION MANUAL - K2 Scientific...7 Last Revised 9/2017 overflow). If necessary, adjust the leveling legs. The unit must be installed with leveling legs to ensure proper operation

20 Last Revised 9/2017

PARTS