23
NJT5677 series] Instruction Manual Revision: 01 Issue Date: November 28, 2011 C-band 5W BUC [NJT5669, NJT5670, NJT5675 & Document Part Number: IM-T5669 IM-T5669 Rev.01 Copyright © 2011, New Japan Radio Co., Ltd. All rights reserved. This instruction manual may not be reproduced, in part or in whole, without the permission of New Japan Radio Co., Ltd. The specifications and information regarding the products in this instruction manual are subject to change without notice. All statements, information, and recommendations in this instruction manual are believed to be accurate but are presented without warranty of any kind, express, or implied. Users must take full responsibility for their application of any products. for NJT5669/70/75/77 series Instruction Manual Page 1

Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

  • Upload
    others

  • View
    12

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

NJT5677 series]

Instruction Manual

Revision: 01

Issue Date: November 28, 2011

C-band 5W BUC[NJT5669, NJT5670, NJT5675 &

Document Part Number: IM-T5669

IM-T5669 Rev.01

Copyright © 2011, New Japan Radio Co., Ltd. All rights reserved.This instruction manual may not be reproduced, in part or inwhole, without the permission of New Japan Radio Co., Ltd.

The specifications and information regarding the products in thisinstruction manual are subject to change without notice.All statements, information, and recommendations in this

instruction manual are believed to be accurate but are presentedwithout warranty of any kind, express, or implied.

Users must take full responsibility for their application of anyproducts.

for

NJT5669/70/75/77 series Instruction Manual Page 1

Page 2: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

1.

2.

3.

4.

5.

NJRC strives to produce reliable and high quality microwave components.NJRC's microwave components are intended for specific applications andrequire proper maintenance and handling. To enhance the performanceand service of NJRC's microwave components, the devices, machinery orequipment into which they are integrated should undergo preventativemaintenance and inspection at regularly scheduled intervals. Failure toproperly maintain equipment and machinery incorporating these productscan result in catastrophic system failures.

To ensure the highest levels of reliability, NJRC products must always beproperly handled. The introduction of external contaminants (e.g. dust, oilor cosmetics) can result in failures of microwave components.

NJRC offers a variety of microwave components intended for particularapplications. It is important that you select the proper component for yourintended application. You may contact NJRC's sales office or salesrepresentatives, if you are uncertain about the products listed in thecatalog and the specification sheets.

Special care is required in designing devices, machinery or equipment,which demand high levels of reliability. This is particularly important whendesigning critical components or systems whose foreseeable failure canresult in situations that could adversely affect health or safety. Indesigning such critical devices, equipment or machinery, carefulconsideration should be given to, amongst other things, their safetydesign, fail-safe design, back-up and redundancy systems, and diffusiondesign.

The products listed in the catalog and specification sheets may not beappropriate for use in certain equipment where reliability is critical orwhere the products may be subjected to extreme conditions. You shouldconsult our sales office or sales representatives before using the productsin any of the following types of equipment.* Aerospace Equipment* Equipment Used in the Deep Sea* Power Generator Control Equipment (nuclear, steam, hydraulic)* Life Maintenance Medical Equipment* Fire Alarm/Intruder Detector* Vehicle Control Equipment (automobile, airplane, railroad, ship, etc.)* Various Safety Equipment

General Caution

IM-T5669 Rev.01

NJT5669/70/75/77 series Instruction Manual Page 2

Page 3: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

6.

General Caution (continued)

NJRC's products have been designed and tested to function withincontrolled environmental conditions. Do not use products under conditionsthat deviate from methods or applications specified in the catalog andspecification sheets. Failure to employ NJRC's products in the properapplications can lead to deterioration, destruction or failure of theproducts. NJRC shall not be responsible for any bodily injury, fires oraccidents, property damage or any consequential damages resulting fromthe misuse or misapplication of its products. PRODUCTS ARE SOLDWITHOUT WARRANTY OF ANY OF KIND, EITHER EXPRESS OR IMPLIED,INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

IM-T5669 Rev.01

NJT5669/70/75/77 series Instruction Manual Page 3

Page 4: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

Contents

This instruction manual is intended for use by trained field installers or systemengineers responsible for satellite networks.

Updated instruction manual may be available from NJRC's sales [email protected].

IM-T5669 Rev.01

22 - 23

About This Instruction Manual

This instruction manual describes C-band 5W BUC (Model No.: NJT5669,NJT5669F, NJT5670, NJT5670F, NJT5675N, NJT5675F, NJT5677N and NJT5677F)herein referred to as "the Unit".

This instruction manual provides information and instructions for installation andoperation of the Unit.

1. Introduction ………………………………………………………………………………

2. Safety Instructions ……………………………………………………………………

3. Packing List ………………………………………………………………………………

14 - 17

18 - 21

7 - 10

6. Installing ……………………………………………………………………………………

12 - 13

5. Physical Description …………………………………………………………………

4. Overview ……………………………………………………………………………………

7. Specification ………………………………………………………………………………

5 - 6

11

NJT5669/70/75/77 series Instruction Manual Page 4

Page 5: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

Full C-band 5W BUC (Model No.: NJT5677N and NJT5677F) receives a referencesignal (10 MHz) and an IF signal (L‐Band: 950 to 1,825 MHz) input and transmitsan RF signal (Palapa C-band: 6.85 to 6.725 GHz) output.

NJT5677N Full C-band, N-type female Interfece Connector NJT5677F

Palapa C-band 5W BUC (Model No.: NJT5675N and NJT5675F) receives areference signal (10 MHz) and an IF signal (L‐Band: 1,065 to 1,425 MHz) inputand transmits an RF signal (Palapa C-band: 6.365 to 6.725 GHz) output.

Insat C-band 5W BUC (Model No.: NJT5670 and NJT5670F) receives a referencesignal (10 MHz) and an IF signal (L‐Band: 965 to 1,265 MHz) input and transmitsan RF signal (Insat C-band: 6.725 to 7.025 GHz) output.

Insat C-band, N-type female Interfece ConnectorInsat C-band, F-type female Interfece Connector

Full C-band, F-type female Interfece Connector

The Unit comes in a single, weatherized housing rated for outdoor use. The Unithas either an N-Type or a F-type female connector input, a WR137 waveguide(CPR 137 grooved flange) output. The Unit is operated by +24 V DC power(Range: +15 to +30 V) input.

This instruction manual is for C-band 5W BUC with followint model number:NJT5669, NJT5669F, NJT5670, NJT5670F, NJT5675N, NJT5675F, NJT5677N andNJT5677F.

1. Introduction

Standard C-band 5W BUC (Model No.: NJT5669 and NJT5669F) receives areference signal (10 MHz) and an IF signal (L‐Band: 950 to 1,525 MHz) input andtransmits an RF signal (Standard C-band: 5.850 to 6.425 GHz) output.

IM-T5669 Rev.01

The line-up is mentioned in a chart below.Line-up DescriptionStandard C-band, N-type female Interfece ConnectorStandard C-band, F-type female Interfece ConnectorPalapa C-band, N-type female Interfece ConnectorPalapa C-band, F-type female Interfece Connector

NJT5670 NJT5670F

Model Number NJT5669 NJT5669F NJT5675N NJT5675F

NJT5669/70/75/77 series Instruction Manual Page 5

Page 6: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

5.850 to 6.725 GHz

4.90 GHz950 to 1,825 MHz NJT5677F

IM-T5669 Rev.01

Local OscillationFrequency

IFFrequency

RefefenceFrequency

NJT5677N

ModelNumber

NJT5669 5.850 to 6.425 GHz

4.90 GHz950 to 1,525 MHz NJT5669F

6.725 to 7.025 GHz

5.76 GHz965 to 1,265 MHz NJT5670F

NJT5675N 6.365 to 6.725 GHz

5.30 GHz1,065 to 1,425 MHz NJT5675F

RFFrequency

10 MHz

The detail of frequency for the reference, IF, RF and local oscillaton is mentionedin a chart below.

NJT5670

NJT5669/70/75/77 series Instruction Manual Page 6

Page 7: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

DANGER, WARNING, CAUTION, and NOTE statements are used throughoutthis instruction manual to emphasize important and critical information. Youmust read these statements to help ensure safety and to prevent productdamage. The statement are defined below.

DANGER, WARNING, CAUTION, and NOTE Statements

Use the following safety guidelines to help protect the Unit from potential damageand to help ensure your own personal safety.

Statement Symbol DescriptionDANGER DANGER indicates an imminently

hazardous situation which, if notavoided, will result in death orserious injury.

WARNING WARNING indicates a potentiallyhazardous situation which, if notavoided, could result in death orserious injury.

CAUTION indicates a potentiallyhazardous situation which, if notavoided, could result in minor ormoderate injury. CAUTION mayalso be used to indicate otherunsafe practices or risks ofproperty damage.

NOTE NOTE is used to notify ofinstallation, operation, ormaintenance information that isimportant, but not hazard-related.

IM-T5669 Rev.01

2. Safety Instructions

CAUTION

NJT5669/70/75/77 series Instruction Manual Page 7

Page 8: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

IM-T5669 Rev.01

When installing the Unit, observe the following safety guidelines.

A radiation hazard exists if the BUC is operated with its RFsignal output unterminated.DO NOT operate the BUC without a load or terminationattached to the RF signal output.

1. Opening / Removing

2. Input VoltageOnly input a voltage within the range indicated in specifiedvoltage.DO operate at the input voltage of +15 to +30 V DC power.

Symbol DescriptionGENERIC HAZARD

DO NOT dismantle this product.Dismantlement may cause malfunction and electric shock.

ELECTRIC HAZARD

HOT SURFACE

2.1. Safety Statements

3. RF Radiation

NJT5669/70/75/77 series Instruction Manual Page 8

Page 9: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

5. Input Level

IM-T5669 Rev.01

4. High Temperatures

DO NOT input an IF signal over the range of +13 dBmmaximum and a reference signal within the range of -5 to +5dBm.

6. Operating Temperature.

DO NOT touch the body, especially fins, during operating theUnit.High touch temperatures may exist, depending on loadconditions.

Operate the Unit within the ambient temperature range of -40to +55 degree C.

2.2. Instruction Statements

1. MountingDO NOT block the fins.Normally the Unit should be mounted with long fins face up.

2. WeatherproofThe Unit is mounted outdoors must be adequatelyweatherproofed.Ensure the waveguide joints are properly sealed with thesupplied o-ring (gasket).Use self-amalgamating tape to seal connectors and cable entrypoints from the connector to the cable sheath.

NJT5669/70/75/77 series Instruction Manual Page 9

Page 10: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

DO NOT touch the filter in the waveguide output.The filter is used for Receive band noise and spurious rejection.If the filter is damaged or dirty, it may not reject a sufficientvalue of false receive band.

IM-T5669 Rev.01

4. ConnecterConnect the IF cable to the input connector of both N and F-type with 0.68 to 1.13 N・m torque.

5. WarrantyOpening or removing any component (e.g. label, and screws)or sealed area will immediately void the warranty.

3. Waveguide

NJT5669/70/75/77 series Instruction Manual Page 10

Page 11: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

Description

NJT5669, NJT5669F, NJT5670, NJT5670F, NJT5675N,

Accessory of BUC

NJT5675F, NJT5677N,

C-band 5W BUC

ORNJT5677F

Date sheetQty(1), O-ring

3.

Qty

1 sheet

1 unit

1 set

IM-T5669 Rev.01

1.

2.

No.

The Unit is shipped in a single shipping container with the following content:

3. Packing List

NJT5669/70/75/77 series Instruction Manual Page 11

Page 12: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

NJT5677N Full C-band, N-type female Interfece Connector NJT5677F Full C-band, F-type female Interfece Connector

Insat C-band, F-type female Interfece Connector NJT5670F

Palapa C-band, F-type female Interfece Connector

NJT5670 Insat C-band, N-type female Interfece Connector

The unique features are ・ High Efficiency & Low Distortion * P1dB: +37 dBm min. over temperature * Power Consumption: 48 W max. ・ Various RF Frequency Line-up: * Standard C-band: 5.85 to 6.425 GHz * Palapa C-band: 6.365 to 6.725 GHz * Full C-band: 5.85 to 6.725 GHz * Insat C-band: 6.725 to 7.025 GHz ・ Small Size & Light Weight * Dimension: (L) 190.6 x (W) 160 x (H) 59 mm [7.50" x 6.30" x 2.32"] * Weight: 1.9 kg [4.2 lbs] ・ LED Indicator ・ RoHS Compliance

The Unit transmits an RF singal of C-band with up to 5W (+37 dBm) linear.

IM-T5669 Rev.01

4. Overview

NJT5669F Standard C-band, F-type female Interfece Connector NJT5675N Palapa C-band, N-type female Interfece Connector NJT5675F

NJT5669 Standard C-band, N-type female Interfece ConnectorModel Number Line-up Description

The line-up is mentioned in a chart below.

NJT5669/70/75/77 series Instruction Manual Page 12

Page 13: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

IM-T5669 Rev.01

Block Diagram

NJT5669/70/75/77 series Instruction Manual Page 13

Page 14: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

Overall Picture (N-type Female Connector)

This section describes appearance and outline for the Unit.

IM-T5669 Rev.01

5.1. Appearance

5. Physical Description

NJT5669/70/75/77 series Instruction Manual Page 14

Page 15: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

5.2.1. Outline Drawing of N-type Female Connector Model

IM-T5669 Rev.01

5.2. Outline

25.8

80

48 .5

81

LED I n d i c a t o r

N o.10-32UNFd e p t h 6 m i n.

160

80

59

25.8

8-N o.10-32UNFd e p t h 6 m i n.

DC P ow e r : +15 t o +30 VDC

N o.10-32UNFd e p t h 6 m i n.

U n i t : mm

190

.6

42 .9

103

(166 .9)

N- t y p e, f em a l e c o n n e c t o rI F / R e f. (10MH z )

CPR-137G

Ground Hole

NJT5669/70/75/77 series Instruction Manual Page 15

Page 16: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

5.2.2. Outline Drawing of F-type Female Connector Model

IM-T5669 Rev.01

25.8

80

48 .5

81

LED I n d i c a t o r

N o.10-32UNFd e p t h 6 m i n.

160

80

59

25.8

8-N o.10-32UNFd e p t h 6 m i n.

N o.10-32UNFd e p t h 6 m i n.

U n i t : mm

190

.6

42 .9

103

(161 .8)

DC P ow e r : +15 t o +30 VDC

F- t y p e, f em a l e c o n n e c t o rI F / R e f . (10MH z )

CPR-137G

Ground Hole

NJT5669/70/75/77 series Instruction Manual Page 16

Page 17: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

RED: L.O. unlocked (or no referencesignal)

N-typeORF-typeFemaleConnectorCPR-137G

LEDIndicator

Item DescriptionIF / ReferenceInputandDC Power Input

RF Output(Waveguide)

Local Unlock Alarm GREEN: L.O. locked

PurposeThe Unit receives an IF signal and areference signal and is required tosupply +15 to +30 V DC power via thisconnector.

The Unit transmits an RF signal via thiswaveguide.

5.3. Description of Connectors, Switches, and LEDs

IM-T5669 Rev.01

GroundHole

M4 Threaded Hole Common chassis ground

NJT5669/70/75/77 series Instruction Manual Page 17

Page 18: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

Step 1: Verify that the groove on the waveguide flange of the Unit for theo-ring is clean.Insert the supplied o-ring (gasket) the groove as shown in a figurebelow.

6. Installing

This section describes basic installation for the Unit.

IM-T5669 Rev.01

6.1. Mounting ConfigurationThe Unit can be mounted with OMT or the waveguide filter of the satelliteantenna.

When mounting on the OMT or the waveguide filter, follow the followingcaution:

DO NOT block the fins.Normally the Unit should be mounted with long fins face up.

When mounting with the OMT or the waveguide filter, follow the followingsteps:

Insaeting O-ring

NJT5669/70/75/77 series Instruction Manual Page 18

Page 19: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

The Unit must be adequately weatherproofed to place inoutdoor.Ensure that the waveguide joint is properly sealed with thesupplied o-ring (gasket).

IM-T5669 Rev.01

5/8"3/4"7/8"

Step 2: Prepare the bolts or screws of the length based on a table below,spring washers, and flat washers for No.10-32UNF of 8 sets, beforefixing the OMT or the waveguide filter.Secure the OMT or the waveguide filter to the Unit by fixing thebolts or screws with 2.39 to 2.91 N・m torque as shown in a figurebelow.

Insaeting O-ring

Table 7. Screw Length ListFlange Thickness of OMT or2 - 5 mm [0.075" - 0.2"]5 - 8.5 mm [0.2" - 0.325"]8.5 - 11.5 mm [0.325" -11.5 - 15 mm [0.45" -

Screw Length1/2"

NJT5669/70/75/77 series Instruction Manual Page 19

Page 20: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

DO NOT input an IF signal over the range of +13 dBmmaximum and a reference signal within the range of -5 to +5dBm.

Step 2: Use self-amalgamating tape to seal connector and cable entrypoints from the connector to the cable sheath.

Only input a voltage within the range indicated in specifiedvoltage.DO operate at the input voltage of +15 to +30 V DC power atthe coaxial connecter on the Unit.

6.2.1. Connecting Coaxical Cable.

IM-T5669 Rev.01

6.2. Connecting ModemThe Unit is connected the modem.

Step 1:

Location of Coaxial Connector

The Unit receives the reference and the IF signal and is required to supply+15 to +30 V DC power from the modem via coaxial cable.

When connecting the coaxial cable from the modem, follow the followingsteps:

Connect the coaxial cable with the N or F-type male connectorsto the coaxial connecter equipped with the Unit which is shownin a figure below under 0.68 to 1.13 N・m torque.

Supplied the IF/Ref./DC Power via Coaxial Cable

NJT5669/70/75/77 series Instruction Manual Page 20

Page 21: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

Step 1:

Fixing a ground wire from the common ground of other equipments forgrounding is proceed with the following step:

Fix the ground wire from other equipments to the ground holenear the coaxical connector with enclosed on the Unit which isshown in a figure below.

To reduce the risk of damage or broken by lightning surge, theUnit should be fixed with the ground wire.

6.2.2. Fixing Ground WireThe Unit should be common with ground of other equipments (e.g.antenna).

Location of Ground Wire

IM-T5669 Rev.01

Fixing the Ground Wire

NJT5669/70/75/77 series Instruction Manual Page 21

Page 22: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

<Standard C-band><Palapa C-band><Full C-band><Insat C-band>

<Standard C-band><Palapa C-band><Full C-band><Insat C-band>

<Standard C-band><Palapa C-band><Full C-band><Insat C-band>

5.850 to 6.725 GHz

950 to 1,825 MHz

4.90 GHz

7.1. Electrical Specifications

4.5. 13.05 GHz

Positive

-5 to +5 dBm @ Input port

-140 dBc/Hz max. @ 10 kHz

10 MHz (sine-wave)

Requirement for External Reference

[Frequency][Input Power][Phase Noise] -120 dBc/Hz max. @ 100 Hz

IM-T5669 Rev.01

-130 dBc/Hz max. @ 1 kHz

<F-type>

2 : 1 max.

-100 dBc/Hz max. @ 1MHz

<N-type>

61 dB nom.

-60 dBc/Hz max. @ 100 Hz-70 dBc/Hz max. @ 1 kHz-80 dBc/Hz max. @ 10 kHz-90 dBc/Hz max. @ 100 kHz

2 : 1 max.Input VSWROutput VSWR

Input Impedance

12.

8.

6.7.

13.

L.O. Phase Noise

Linear Gain

10.

2.

+37 dBm min. over temperature

Single, fixed L.O.

3.

7. Specification

No. Item Specifications

L.O. Frequency

Frequency SenseOutput Power @ 1dB G.C.P.

1.5.850 to 6.425 GHz6.365 to 6.725 GHz

6.725 to 7.025 GHz

950 to 1,525 MHz

The Unit is in compliance with the following specifications:

Conversion Type

+13 dBm max.

Output Frequency Range

Input Frequency Range

Maximum IF Input Level (without damage)

11.

9.

1,065 to 1,425 MHz

965 to 1,265 MHz

4.90 GHz5.30 GHz

5.76 GHz

75 ohms nominal50 ohms nominal

NJT5669/70/75/77 series Instruction Manual Page 22

Page 23: Instruction Manual for C-band 5W BUC [NJT5669, NJT5670

Output Load VSWR for NonDamage

[Voltage Range]48 W max.[Power Consumption]+24 VDC (+15 to +30 VDC)

DC Power Requirement

0 to 100 %

190.6 mm [7.50"]

7. Humidity

10. Comply with RoHS (Restricting the use of Hazardous Substances)directives

9. Regulatory Compliance CE / EMC Directive (2004/108/EC)IP67 (IEC 60529)

6. Temperature Range (ambient)

-40 to +75 °C-40 to +55 °C

No. Item7.2. Mechanical and Environmental Specification:

Shut off the HPA in case of L.O.unlocked

Specifications

5. Cooling Convection Cooling

(L) (W) (H)

4.

160 mm [6.30"]59 mm [2.32"]

IF / Ref. / DC Power: N-type, femaleInput Interface

Infinite : 1Item Specifications

IM-T5669 Rev.01

14.No.

1.9 kg [4.2 lbs]

19.

<N-type>

[Storage]

Waveguide, WR137

8. Dustproof / Waterproof

Dimension & Housing

Weight

[Operating]

15.

1.

<F-type>

LED Indicator GREEN: L.O. lockedRED: L.O. unlocked (or no 10 MHz reference signal)

2. Output Interface

3.without Interface Connector

IF / Ref. / DC Power: F-type, female

18. Mute

Flange, CPR137 Grooved

NJT5669/70/75/77 series Instruction Manual Page 23