Instant Digital Pressure = No More Manometer Compass TM Lumbar Puncture Catalog Number: CLPeH2O001 Ordering: (425) 8944134 or [email protected] Measure the Pressure Without the Hassle “Measuring CSF pressure by open ended manometry is fraught with inaccuracies....eyeballing a fluctuating meniscus and the need for several pairs of hands have negated much of its usefulness.” Minns, R.A. Arch. Dis. Child. 1989;64:814820 Attachment and removal of the apparatus may dislodge the needle, particularly in a moving child. It takes time for the CSF to travel up the manometer. Air bubbles in the manometer may interfere with accurate readings.” Ellis, RW et al. Pediatrics. 1992;89:895897 Simple: Easily operated by a single user DigiPop: Pressure bars spike when the needle hits the CSF. No need to wait for fluid to confirm needle entry. Versatile: Connects to any standard needle or catheter Instant opening pressure: Save time – stop waiting for a manometer to fill Save your patients from extra discomfort

InstantDigital&Pressure&=No&MoreManometer& - CAREstream …carestreammedical.com/wp-content/uploads/Carestrea… ·  · 2015-11-10Microsoft Word - CompassLP_Brochure.docx Author:

  • Upload
    vodung

  • View
    215

  • Download
    3

Embed Size (px)

Citation preview

 

Instant  Digital  Pressure  =  No  More  Manometer    

CompassTM  Lumbar  Puncture  

Catalog  Number:  CLPeH2O001                                                        Ordering:  (425)  894-­‐4134  or  [email protected]  

Measure  the  Pressure  Without  the  Hassle  

“Measuring  CSF  pressure  by  open  ended  manometry  is  fraught  with  inaccuracies....eyeballing  a  fluctuating  meniscus  and  the  need  for  several  pairs  of  hands  have  negated  much  of  its  usefulness.”  

Minns,  R.A.  Arch.  Dis.  Child.  1989;64:814-­‐820      

“Attachment  and  removal  of  the  apparatus  may  dislodge  the  needle,  particularly  in  a  moving  child.  It  takes  time  for  the  CSF  to  travel  up  the  manometer.    Air  bubbles  in  the  manometer  may  interfere  with  accurate  readings.”  

Ellis,  RW  et  al.  Pediatrics.  1992;89:895-­‐897  

Simple:  Easily  operated  by  a  single  user  

Digi-­‐Pop:  Pressure  bars  spike  when  the  needle  hits  the  CSF.    No  need  to  wait  for  fluid  to  confirm  needle  entry.  

Versatile:  Connects  to  any  standard  needle  or  catheter  

Instant  opening  pressure:  Save  time  –  stop  waiting  for  a  manometer  to  fill  Save  your  patients  from  extra  discomfort      

3.  Remove  stylet,  and  attach  Compass  to  needle.  Cover  the  rear  Compass  port  with  thumb  and  advance  until  Digi-­‐Pop  indicates  CSF  entry.    Record  opening  pressure.  

Catalog Number: CLPeH2O001 Ordering: (425) 894-4134 or [email protected]

Pressure  Range   -­‐199  to  +  199  cm  H2O  Accuracy   ±3  cm  H2O  

Operational  Life   8  hours  Battery  Voltage   3  V  

 

Sterile   Non-­‐Pyrogenic  Single  Use   Latex  Free  

 

Specifications    

Quick  Tips:  Rapid  Pressure  Measurement  During  Lumbar  Puncture    

1.  Turn  on  Compass  by  depressing  green  button  until  00  cm  appears.  

2.  Insert  spinal  needle  and  stylet  into  ligament.  

5.  Record  closing  pressure  by  placing  thumb  or  cap  on  rear  Compass  port.  

6.  Remove  Compass,  insert  stylet,  and  withdraw  needle.  

Pressure  displayed  as  an  average  pressure  and  continuously  updating  pressure  bars  to  show  CSF  pressure  fluctuations    

Go to www.miradorbiomedical.com for animated video demonstration

4.  Collect  CSF  sample.