Installation/Operating Guidelines
motionlift™-Motorized Projector Lift
Dimens ion&Data
T100A 450×450×145 15 1000
T100B 15 1000
T120 508×508×165 25 1 2 0 0
T150 508×508×190 30 1 5 0 0
S180A 508×508×210 3 0 1 8 0 0
S180B 700×508×210 5 0 1 8 0 0
S240 700×508×240 5 0 2 4 0 0
S300 700×508×280 5 0 3 0 0 0
S360 700×508×320 5 0 3 6 0 0
53mm
53mm
53mm
53mm
53mm
48mm
48mm
48mm
48mm
Voltage,frequency and currency
Tr(mm)
Lift DimensionAxBxC (mm)
Loading Capability
(kg)
Approx. Travel time
(Sec) M o d e l
AC220-230V 50HZ 115W
AC220-230V 50HZ 115W
AC220-230V 50HZ 115W
AC220-230V 50HZ 115W
AC220-230V 50HZ 200W
AC220-230V 50HZ 200W
AC220-230V 50HZ 200W
AC220-230V 50HZ 200W
AC220-230V 50HZ 115W
Height of lift in closed position
600X600
Ceiling plate
EXF(mm) GXK(mm)
Ceiling opening
550X550
600X600 550X550
550X550600X600
600X600 550X550
600X600 550X550
820X550870X600
870X600 820X550
820X550870X600
870X600 820X550
1 4 5
1 4 5
165
1 9 0
2 1 0
2 1 0
2 4 0
2 8 0
3 2 0
T80A 450×450×145 15 800
T80B 508×508×145 15 800
AC220-230V 50HZ 115W
AC220-230V 50HZ 115W
600X600 550X550
600X600 550X550
53mm
53mm
508x508x145
1 4 5
1 4 5
Page 1 of 6
© Copyright all rights reserved.This drawing is the property of Ergomotion Pty Ltd. It may not be copied in whole or part nor can it beused for the manufacture of any equipment described without written permission of Ergomotion.Ergomotion reserves the right to change, without notice, the specifications and materials contained inthis drawing and shall not be responsible for any damages (including consequential) caused byreliance on the information presented.
Screw rod
Accessories( ) optional
Ф 4 hexangular key
Limi t swi tcn hexangular key
M8×280×4pcs
M8 hex nut x 8pcs
Dimensions in :mm
M5×12×4pcs
M4×12×4pcs
M3×4×4pcs
Screws:
O v e r a l l l e n g t h A
33
0C
BB 6 5 m m+
L3
30
C+
20
0
F天花
Ceiling decorated plate
U p p e r S e c t i o n
L i f t
H e i g h t o f p r o j e c t o r
Ceiling opening
Ceiling plate
O v e r a l l w i d t h
Ov
era
ll he
igh
t
Ma
x tra
ve
l d
ista
nc
e
Ceiling opening
Ceiling plate
Remote ontrol Transmitter c Projector niversal racket u b
Ceiling plate frame Pul l ing screw
Lateral
diagram
(Elevation)Projector
Projector
G
E
K
F
NOTE: M8x3 hex nut x 2pcs(for T80A and T100A models only-to fit rod in to underside of lift enclosure (front end))See Figure 3 on page 4
Page 2 of 6
© Copyright all rights reserved.This drawing is the property of Ergomotion Pty Ltd. It may not be copied in whole or part nor can it beused for the manufacture of any equipment described without written permission of Ergomotion.Ergomotion reserves the right to change, without notice, the specifications and materials contained inthis drawing and shall not be responsible for any damages (including consequential) caused byreliance on the information presented.
Motor
EN
RL
EN
L
220V
-230
V,5
0HZ
Remote contol(IR/RF)
Motor
220V
-230
V,50
HZw
ire
switc
h
wire
switc
hbo
x
Motor
wir
esw
itch
wire
switc
hb
ox
110V
-120
V,6
0HZ
Motor
EN
RL
EN
L
110V
-120
V,6
0HZ
Remote contol(IR/RF)
Wiring Diagrams
!
! !● Make sure that currency is up to the standard of motorized projector l ift.
● Make sure all parts are supplied.
● Do not place motorized projector l ift near any hot, inflammable and explosive objects. Fire, electricshocks, or short circuits may result from damage of cable.
● Intallation and electrical connection must be carried out by a qualified technician, if installation is notcarried out correctly, there is the danger that fire and electric shock may occur.
●
Fasteners, supports or ceil ing must be of adequate strength to securely support Motorized ProjectorLift and projector.
● Make sure the space is enough for install ing, minimal height including motorized projector l ift, height of projector, thickness of ceil ing, etc.
K
Ceiling opening
G
Preparation for installation
● Open carton and inspect for damage and all parts are enclosed.● Confirm that there is adequate space for installation and operation.
● Ensure that all fasteners and supports and ceiling are of adequate strength to securely support Motorized Projector Lift and projector.
● Minimum clearance above ceiling level varies according to Motorized Projector Lift plus height of projector, optional projector mounting bracket, optional ceil ing ceil ing plate.
● Make sure the batteries are working in the Receiver.
● Installation must be carried out by at least 2 qualified technic ians.
Caution: Read instructions completely before proceeding.THE LIFT CANNOT BE EXTENDED MANUALLY IF THERE IS NO POWER TO THE MOTOROR IF THERE IS A FAILURE. MAKE SURE THERE IS ACCESS TO THE LIFT FROM WITHINTHE CEILING SO IT CAN BE REMOVED AND RETURNED IF NECESSARY.
Page 3 of 6
ONLY CONNECT TO MAINS POWER ONCE ALL ELECTRICAL CONNECTIONS HAVE BEEN MADE
© Copyright all rights reserved.This drawing is the property of Ergomotion Pty Ltd. It may not be copied in whole or part nor can it beused for the manufacture of any equipment described without written permission of Ergomotion.Ergomotion reserves the right to change, without notice, the specifications and materials contained inthis drawing and shall not be responsible for any damages (including consequential) caused byreliance on the information presented.
B+32mm
A-5
0mm
K
G
(图一) (图二)
Installation of Motorized Projector Lift
● Refer to the following diagram(F 1)
● Anchor the four holes with 4 unit of M8 Pulling Screws and clinch nuts(F 2)
igure
igure
Installation of ceil ing decorated plate
●Connect the plug to power
●Lower motorized projector l ift by
remote transmitter.
●Thread 4 units of screw rod to the
holes in l ift mount and ceiling plate.
●The height and clearance of ceil ing
plate can be adjusted by nuts.
Choose proper screws for ceil ing plate,
securely anchor the frame of ceil ing plate
to ceil ing opening(Figure 3)
●
上侧吊架底盘
螺杆安装架
下侧
(Figure1) (Figure 2)
Vniversal bracket fixing
Screws for projector
Install ing projector.
●Install projector in universal bracket with proper screws
according to the s ize of projector and tighten them.
●Install the universal bracket to the middle bottom of the
l ift and tighten the screws.
●Lace the cables and link it “Z”and attach to the plastic
ring of scissors.
Connect the plugs of Motorized Projector Lift and projector
in the socket.
●
Angle adjustment of projector.Change the height of projector through adjusting
the pole of the universal bracket according to
the screw hole
●
Page 4 of 6
© Copyright all rights reserved.This drawing is the property of Ergomotion Pty Ltd. It may not be copied in whole or part nor can it beused for the manufacture of any equipment described without written permission of Ergomotion.Ergomotion reserves the right to change, without notice, the specifications and materials contained inthis drawing and shall not be responsible for any damages (including consequential) caused byreliance on the information presented.
(Figure 3)
2xM8x3 hex nut for T80A and T100A models only-to go in these 2 positions only (use instead of M8x6 hex nut)
Travel distance adjustment (holes are on left of the motor when looking from the front)● Insert Travel Adjustable Hexangular key into the adjusting hole of motor● The right hole (front/closest hole when looking from the front) is for adjusting LOWER limit.
Antic lockwise movement is for increasing lower limit, c lockwise movement is for reducing lower limit.● The left hole (back/furthest hole when look from the front) is for adjusting UPPER limit. Antic lockwise movement is for increasing upper l imit, c lockwise movement is for reducing upper l imit.
Limit switch hexagonal key
Green Straps
Adjusting holesOn the underside of thiscover on the end of thedrum motor-left handside when looking fromthe front (see photo below)
Page 5 of 6
motionlift full assembly
© Copyright all rights reserved.This drawing is the property of Ergomotion Pty Ltd. It may not be copied in whole or part nor can it beused for the manufacture of any equipment described without written permission of Ergomotion.Ergomotion reserves the right to change, without notice, the specifications and materials contained inthis drawing and shall not be responsible for any damages (including consequential) caused byreliance on the information presented.
Adjusting limit holes (yellow screws in black casing) on left of motor when looking at the underside of the lift from the front
WARNING:- Adjust upper and lower limits to suit the installation dimensions. Make sure motor shuts down on both of these limit switches. If the motor does not shut down on these limit switches there is a risk of damage to the motor and lift mechanism, which will void your warranty
Page 6 of 6
Up/Down panel with built in IR eye
Assembly of the additional IR eye and microswitch in to the ceiling plate
Photos to help with installation of lift
Additional microswitch to lower lift if remote control does not work(Insert pin into hole of ceiling plate to activate switch and lower the lift)
© Copyright all rights reserved.This drawing is the property of Ergomotion Pty Ltd. It may not be copied in whole or part nor can it beused for the manufacture of any equipment described without written permission of Ergomotion.Ergomotion reserves the right to change, without notice, the specifications and materials contained inthis drawing and shall not be responsible for any damages (including consequential) caused byreliance on the information presented.
IR eye for ceiling plate