21
© 2009 Copyright Energy, Inc. All rights reserved Installation of TED 5000 The following images are simply a visual for the steps taken for the installation of TED. This is not a substitute for reading the detail installation instructions In the Instruction Manual. Before installation, read the Installation and Instruction Manuals and understand fully the Safety requirements.

Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

Embed Size (px)

Citation preview

Page 1: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Installation of TED 5000

The following images are simply a visual for the steps taken for the installation of TED. This is not a substitute

for reading the detail installation instructions In the Instruction Manual.

Before installation, read the Installation and Instruction Manuals and understand fully the Safety requirements.

Page 2: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Three components of TED5000 mount in the electrical panel:

MTU Power Cable

MTU(Measuring Transmitting Unit)

CTs (Current Transformers)

Page 3: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

MTU Power Cable

2 Hot Leads (Red & Black) connect to each phase on a 15/20/30 amp breaker

Molex plug fits into MTU

White connects to Neutral Bus

Page 4: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Typical Combination Electrical Panel

200Amp

Page 5: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Turn OFF the Main Breaker

Page 6: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

There is a RED Dot on one side of the CTs. Note them when installing CTs.

Page 7: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Danger - AVOID

Note RED polarity dot facing Main Breaker

Danger - AVOIDDanger - AVOID

Page 8: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Clip CT completely over conductor

Page 9: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Correctly connected CT – (it does not need to be snug on conductor)

Page 10: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Connect 2nd CT the same as the 1st. NOTE that the RED polarity dotsare both facing the same direction of current flow

Page 11: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Connect CT using special care to avoid hot lugs

Danger - AVOID

Page 12: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Correctly connected CTs

Page 13: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Connect the WHITE lead of the MTU Power Cable to any

available position in the Neutral Bus

Page 14: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

ABABABABABA

ABABABABABA

Select an “A” phase and “B” phase circuit to connect the Red/Black leads;(DO NOT connect black and red to the same phase)

15/20/30 amp breakers are OK.

Page 15: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Turn the breakers OFF on the selected “A” and “B” phase circuits as a precaution

AB

Page 16: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Connect the RED and BLACK leads from the MTU Power Cable to the Selected “A” and “B” phase circuit breakers

AB

Page 17: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Correctly connected RED and BLACK leads from the Power Cable- one connected to each phase

AB

Page 18: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

Note the ‘guides’ on the end of the CT connector. They fit snugly in theslot of the MTU

Page 19: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

The CT connector will fit snugly into the MTU – note the 4 grooves in the top of the CT connector (the 2 “guides” are on the bottom side)

Page 20: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

The last connection is the Power Cable base. There is only 1 way it can be connected. Line up the connector and snap it in to the MTU.

Page 21: Installation of TED 5000 - The Energy Detective (TED) · Title: Microsoft PowerPoint - Installation pictorial.ppt Author: HP_Administrator Created Date: 7/9/2009 2:53:00 PM

© 2009 Copyright Energy, Inc. All rights reserved

After all the connections are made and the MTU Power Cable is connected to the MTU, turn on the Main Breaker and branch circuit breakers. The green LED on the MTU should light up at this point.

For troubleshooting purposes, you may want to leave the panel cover off until you connect the other components (GATEWAY and DISPLAY) to be sure the system is operating properly.

If you have any installation questions, please call our toll-free Support Line: 1(800) 959-5833