INSTALLATION MANUAL BS unit BSVQ100P8V1B BSVQ160P8V1B BSVQ250P8V1B SYSTEM Air Conditioners READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.

INSTALLATION MANUAL · 2021. 1. 24. · installation manual bs unit bsvq100p8v1b bsvq160p8v1b bsvq250p8v1b system air conditioners read these instructions carefully before installation

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • INSTALLATION MANUAL

    BS unit

    BSVQ100P8V1BBSVQ160P8V1BBSVQ250P8V1B

    SYSTEM Air Conditioners

    READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.

  • Dai

    kin

    Eu

    rop

    e N

    .V.

    CE -

    DECL

    ARAT

    ION-

    OF-C

    ONFO

    RMIT

    YCE

    - KO

    NFOR

    MIT

    ÄTSE

    RKLÄ

    RUNG

    CE -

    DECL

    ARAT

    ION-

    DE-C

    ONFO

    RMIT

    ECE

    - CO

    NFOR

    MIT

    EITS

    VERK

    LARI

    NG

    CE -

    DECL

    ARAC

    ION-

    DE-C

    ONFO

    RMID

    ADCE

    - DI

    CHIA

    RAZI

    ONE-

    DI-C

    ONFO

    RMIT

    ACE

    - ¢H

    §ø™H

    ™YM

    MOP

    ºø™H

    CE -

    DECL

    ARAÇ

    ÃO-D

    E-CO

    NFOR

    MID

    ADE

    СЕ -

    ЗАЯВ

    ЛЕНИ

    Е-О

    -СО

    ОТВ

    ЕТСТ

    ВИИ

    CE -

    OPFY

    LDEL

    SESE

    RKLÆ

    RING

    CE -

    FÖRS

    ÄKRA

    N-OM

    -ÖVE

    RENS

    TÄMM

    ELSE

    CE -

    ERKL

    ÆRI

    NG O

    M-S

    AMSV

    ARCE

    - IL

    MOI

    TUS-

    YHDE

    NMUK

    AISU

    UDES

    TACE

    - PR

    OHL

    ÁŠEN

    Í-O-S

    HODĚ

    CE -

    IZJA

    VA-O

    -USK

    LAĐE

    NOST

    ICE

    - M

    EGFE

    LELŐ

    SÉG

    I-NYI

    LATK

    OZA

    TCE

    - DE

    KLAR

    ACJA

    -ZG

    ODN

    OŚC

    ICE

    - DE

    CLAR

    AŢIE

    -DE-

    CONF

    ORM

    ITAT

    E

    CE -

    IZJA

    VA O

    SKL

    ADNO

    STI

    CE -

    VAST

    AVUS

    DEKL

    ARAT

    SIO

    ON

    CE -

    ДЕКЛ

    АРАЦ

    ИЯ-З

    А-СЪ

    ОТВЕ

    ТСТВ

    ИЕ

    CE -

    ATIT

    IKTI

    ES-D

    EKLA

    RACI

    JACE

    - AT

    BILS

    TĪBA

    S-DE

    KLAR

    ĀCIJ

    ACE

    - VY

    HLÁS

    ENIE

    -ZHO

    DYCE

    - UY

    UMLU

    LUK-

    BİLD

    İRİS

    İ

    01ar

    e in

    confo

    rmity

    with

    the

    follo

    wing

    sta

    ndar

    d(s)

    or o

    ther

    nor

    mat

    ive d

    ocum

    ent(s

    ), pr

    ovide

    d th

    at th

    ese

    are

    used

    in a

    ccor

    danc

    e wi

    th o

    urins

    tructi

    ons:

    02de

    r/den

    folge

    nden

    Nor

    m(e

    n) o

    der e

    inem

    and

    eren

    Nor

    mdo

    kum

    ent o

    der -

    doku

    men

    ten

    entsp

    richt

    /ent

    spre

    chen

    , unt

    er d

    er V

    orau

    sset

    zung

    ,da

    ß sie

    gem

    äß u

    nser

    en A

    nweis

    unge

    n ein

    gese

    tzt w

    erde

    n:03

    sont

    confo

    rmes

    à la/

    aux n

    orm

    e(s)

    ou au

    tre(s

    ) doc

    umen

    t(s) n

    orm

    atif(

    s), p

    our a

    utan

    t qu'i

    ls so

    ient u

    tilisé

    s con

    form

    émen

    t à no

    s ins

    tructi

    ons:

    04co

    nform

    de vo

    lgend

    e nor

    m(e

    n) of

    één o

    f mee

    r and

    ere b

    inden

    de do

    cum

    ente

    n zijn

    , op v

    oorw

    aard

    e dat

    ze w

    orde

    n geb

    ruikt

    over

    eenk

    omsti

    gon

    ze in

    struc

    ties:

    05es

    tán

    en co

    nfor

    mida

    d co

    n la(

    s) si

    guien

    te(s

    ) nor

    ma(

    s) u

    otro

    (s) d

    ocum

    ento

    (s) n

    orm

    ativo

    (s),

    siem

    pre

    que

    sean

    utili

    zado

    s de

    acue

    rdo

    con

    nues

    tras i

    nstru

    ccion

    es:

    06so

    no c

    onfor

    mi a

    l(i) s

    egue

    nte(

    i) sta

    ndar

    d(s)

    o a

    ltro(

    i) do

    cum

    ento

    (i) a

    car

    atte

    re n

    orm

    ativo

    , a p

    atto

    che

    ven

    gano

    usa

    ti in

    conf

    orm

    ità a

    lleno

    stre

    istru

    zioni:

    07›Ó

    ·È Û

    ‡Ìʈ

    Ó· Ì

    Â ÙÔ

    (·)

    ·ÎfiÏ

    Ô˘ıÔ

    (·)

    ÚfiÙ

    ˘Ô(

    ·) ‹

    ¿ÏÏ

    Ô ¤Á

    ÁÚ·Ê

    Ô(·)

    ηÓ

    ÔÓÈÛÌÒ

    Ó, ˘

    fi Ù

    ËÓ

    ÚÔ¸

    fiıÂÛ

    Ë fiÙ

    È ¯ÚË

    ÛÈÌÔ

    ÔÈÔ‡Ó

    Ù·È

    Û‡ÌÊ

    ˆÓ·

    ÌÂ Ù

    Ș Ô

    ‰ËÁ›Â˜

    Ì·˜

    :

    08es

    tão

    em c

    onfo

    rmida

    de c

    om a

    (s) s

    eguin

    te(s

    ) nor

    ma(

    s) o

    u ou

    tro(s

    ) doc

    umen

    to(s

    ) nor

    mat

    ivo(s

    ), de

    sde

    que

    este

    s se

    jam u

    tiliza

    dos

    deac

    ordo

    com

    as n

    ossa

    s ins

    truçõ

    es:

    09со

    отве

    тств

    уют

    след

    ующи

    м ст

    анда

    ртам

    или

    дру

    гим

    норм

    атив

    ным

    доку

    мент

    ам, п

    ри у

    слов

    ии и

    х ис

    поль

    зова

    ния

    согл

    асно

    наш

    имин

    стру

    кция

    м:10

    over

    holde

    r fø

    lgend

    e sta

    ndar

    d(er

    ) ell

    er a

    ndet

    /and

    re r

    etnin

    gsgiv

    ende

    dok

    umen

    t(er),

    for

    udsa

    t at

    diss

    e an

    vend

    es i

    henh

    old t

    il vo

    reins

    truks

    er:

    11re

    spek

    tive

    utru

    stning

    är u

    tförd

    i öv

    eren

    sstä

    mm

    else

    med

    och

    följe

    r följ

    ande

    sta

    ndar

    d(er

    ) elle

    r and

    ra n

    orm

    givan

    de d

    okum

    ent,

    unde

    rfö

    rutsä

    ttning

    att

    anvä

    ndnin

    g sk

    er i ö

    vere

    nsstä

    mm

    else

    med

    våra

    instr

    uktio

    ner:

    12re

    spek

    tive

    utsty

    r er i

    ove

    rens

    stem

    mels

    e m

    ed fø

    lgend

    e sta

    ndar

    d(er

    ) elle

    r and

    re n

    orm

    given

    de d

    okum

    ent(e

    r), u

    nder

    foru

    tsset

    ning

    av a

    tdis

    se b

    ruke

    s i h

    enho

    ld til

    våre

    instr

    ukse

    r:13

    vasta

    avat

    seu

    raav

    ien s

    tand

    ardie

    n ja

    muid

    en o

    hjeell

    isten

    dok

    umen

    ttien

    vaat

    imuk

    sia e

    delly

    ttäen

    , et

    tä n

    iitä k

    äyte

    tään

    ohje

    idem

    me

    muk

    aises

    ti:14

    za p

    ředp

    oklad

    u, že

    jsou

    využ

    ívány

    v so

    uladu

    s na

    šimi p

    okyn

    y, o

    dpov

    ídají

    nás

    ledují

    cím n

    orm

    ám n

    ebo

    norm

    ativn

    ím d

    okum

    entů

    m:

    15u

    sklad

    u sa

    slije

    dećim

    stan

    dard

    om(im

    a) ili

    dru

    gim n

    orm

    ativn

    im d

    okum

    ento

    m(im

    a), u

    z uvje

    t da

    se o

    ni ko

    riste

    u sk

    ladu

    s naš

    im u

    puta

    ma:

    16m

    egfe

    lelne

    k az a

    lábbi

    szab

    vány

    (ok)

    nak v

    agy e

    gyéb

    irán

    yadó

    dok

    umen

    tum

    (ok)

    nak,

    ha a

    zoka

    t előí

    rás s

    zerin

    t has

    ználj

    ák:

    17sp

    ełniaj

    ą wy

    mog

    i nas

    tępu

    jącyc

    h no

    rm i

    innyc

    h do

    kum

    entó

    w no

    rmali

    zacy

    jnych

    , pod

    war

    unkie

    m ż

    e uż

    ywan

    e są

    zgo

    dnie

    z na

    szym

    iins

    trukc

    jami:

    18su

    nt în

    conf

    orm

    itate

    cu u

    rmăt

    orul

    (urm

    ătoa

    rele)

    stan

    dard

    (e) s

    au a

    lt(e)

    doc

    umen

    t(e) n

    orm

    ativ(

    e), c

    u co

    ndiţia

    ca a

    ceste

    a să

    fie u

    tiliza

    te în

    conf

    orm

    itate

    cu in

    struc

    ţiunil

    e no

    astre

    19sk

    ladni

    z nas

    lednji

    mi s

    tand

    ardi

    in dr

    ugim

    i nor

    mat

    ivi, p

    od p

    ogoje

    m, d

    a se

    upo

    rablj

    ajo v

    sklad

    u z n

    ašim

    i nav

    odili:

    20on

    vasta

    vuse

    s jär

    gmis(

    t)e st

    anda

    rdi(t

    e)ga

    või te

    iste

    norm

    atiiv

    sete

    dok

    umen

    tideg

    a, ku

    i neid

    kasu

    tata

    kse

    vasta

    valt m

    eie ju

    hend

    itele:

    21съ

    отве

    тств

    ат н

    а сл

    едни

    те с

    танд

    арти

    или

    дру

    ги н

    орма

    тивн

    и до

    куме

    нти,

    при

    усл

    овие

    , че

    се

    изпо

    лзва

    т съ

    глас

    но н

    ашит

    еин

    стру

    кции

    :22

    atitin

    ka že

    miau

    nur

    odytu

    s sta

    ndar

    tus i

    r (ar

    ba) k

    itus n

    orm

    inius

    dok

    umen

    tus s

    u są

    lyga,

    kad

    yra

    naud

    ojam

    i pag

    al m

    ūsų

    nuro

    dym

    us:

    23ta

    d, ja

    lieto

    ti atb

    ilsto

    ši ra

    žotā

    ja no

    rādī

    jumiem

    , atb

    ilst s

    ekojo

    šiem

    stan

    darti

    em u

    n cit

    iem n

    orm

    atīvi

    em d

    okum

    entie

    m:

    24sú

    v zh

    ode

    s nas

    ledov

    nou(

    ými)

    norm

    ou(a

    mi)

    alebo

    iným

    (i) n

    orm

    atívn

    ym(i)

    dok

    umen

    tom

    (am

    i), za

    pre

    dpok

    ladu,

    že sa

    pou

    žívajú

    v sú

    lade

    s naš

    im n

    ávod

    om:

    25ür

    ünün

    , tali

    mat

    larım

    ıza g

    öre

    kulla

    nılm

    ası k

    oşulu

    yla a

    şağı

    daki

    stand

    artla

    r ve

    norm

    beli

    rten

    belge

    lerle

    uyum

    ludur

    :

    01Di

    recti

    ves,

    as a

    men

    ded.

    02Di

    rekti

    ven,

    gem

    äß Ä

    nder

    ung.

    03Di

    recti

    ves,

    telle

    s que

    mod

    ifiées

    .04

    Rich

    tlijne

    n, zo

    als g

    eam

    ende

    erd.

    05Di

    recti

    vas,

    segú

    n lo

    enm

    enda

    do.

    06Di

    rettiv

    e, co

    me

    da m

    odific

    a.07

    √‰Ë

    ÁÈÒv

    , fiˆ

    ˜ ¤¯

    Ô˘Ó

    ÙÚÔ

    ÔÔÈËı

    ›.08

    Dire

    ctiva

    s, co

    nform

    e alt

    eraç

    ão e

    m.

    09Ди

    рект

    ив со

    все

    ми п

    опра

    вкам

    и.

    10Di

    rekti

    ver,

    med

    sene

    re æ

    ndrin

    ger.

    11Di

    rekti

    v, m

    ed fö

    reta

    gna

    ändr

    ingar

    .12

    Dire

    ktive

    r, m

    ed fo

    reta

    tte e

    ndrin

    ger.

    13Di

    rektiiv

    ejä, s

    ellais

    ina ku

    in ne

    ovat

    muute

    ttuina

    .14

    v plat

    ném

    zněn

    í.15

    Smjer

    nice,

    kako

    je iz

    mije

    njeno

    .16

    irány

    elv(e

    k) és

    mód

    osítá

    saik

    rend

    elkez

    éseit

    .17

    z póź

    niejsz

    ymi p

    opra

    wkam

    i.18

    Dire

    ctive

    lor, c

    u am

    enda

    men

    tele

    resp

    ectiv

    e.

    19Di

    rekti

    ve z

    vsem

    i spr

    emem

    bam

    i.20

    Dire

    ktiivi

    d ko

    os m

    uuda

    tuste

    ga.

    21Ди

    рект

    иви,

    с те

    хнит

    е из

    мене

    ния.

    22Di

    rekty

    vose

    su p

    apild

    ymais

    .23

    Dire

    ktīvā

    s un

    to p

    apild

    inājum

    os.

    24Sm

    ernic

    e, v

    platn

    om zn

    ení.

    25De

    ğiştir

    ilmiş

    halle

    riyle

    Yöne

    tmeli

    kler.

    01fol

    lowing

    the

    prov

    ision

    s of:

    02ge

    mäß

    den

    Vor

    schr

    iften

    der:

    03co

    nform

    émen

    t aux

    stipu

    lation

    s des

    :04

    over

    eenk

    omsti

    g de

    bep

    aling

    en va

    n:05

    siguie

    ndo

    las d

    ispos

    icion

    es d

    e:06

    seco

    ndo

    le pr

    escr

    izion

    i per

    :07

    ÌÂ Ù

    ‹ÚËÛ

    Ë Ùˆ

    v ‰È·Ù

    ¿Íˆ

    v Ùˆ

    v:08

    de a

    cord

    o co

    m o

    pre

    visto

    em

    :09

    в со

    отве

    тств

    ии с

    поло

    жени

    ями:

    10un

    der i

    agtta

    gelse

    af b

    este

    mm

    elser

    ne i:

    11en

    ligt v

    illkor

    en i:

    12git

    t i he

    nhold

    til b

    este

    mm

    elsen

    e i:

    13no

    udat

    taen

    mää

    räyk

    siä:

    14za

    dod

    ržen

    í usta

    nove

    ní p

    ředp

    isu:

    15pr

    ema

    odre

    dbam

    a:16

    köve

    ti a(z

    ):17

    zgod

    nie z

    posta

    nowi

    eniam

    i Dyr

    ektyw

    :18

    în u

    rma

    prev

    eder

    ilor:

    19ob

    upo

    števa

    nju d

    oločb

    :20

    vasta

    valt n

    õuet

    ele:

    21сл

    едва

    йки

    клау

    зите

    на:

    22lai

    kant

    is nu

    osta

    tų, p

    ateik

    iamų:

    23iev

    ērojo

    t pra

    sības

    , kas

    not

    eikta

    s:24

    održ

    iavajú

    c usta

    nove

    nia:

    25bu

    nun

    koşu

    lların

    a uy

    gun

    olara

    k:

    01

    Note

    *as

    set o

    ut in

    a

    nd ju

    dged

    posit

    ively

    by ac

    cordi

    ng to

    the

    Certi

    ficate

    .

    02

    Hinw

    eis *

    wie i

    n der

    a

    ufgefü

    hrt u

    nd vo

    n <B>

    posit

    iv be

    urtei

    lt gem

    äß Ze

    rtifik

    at .03

    Re

    marq

    ue *

    tel qu

    e défi

    ni da

    ns et é

    valué

    posit

    iveme

    nt pa

    r con

    formé

    ment

    au C

    ertifi

    cat <

    C>.

    04

    Beme

    rk *

    zoals

    verm

    eld in

    e

    n pos

    itief b

    eoord

    eeld

    door

    o

    veree

    nkom

    stig C

    ertifi

    caat

    .

    05

    Nota

    *co

    mo se

    estab

    lece e

    n <A>

    y es

    valor

    ado

    posit

    ivame

    nte po

    r <B>

    de ac

    uerdo

    con e

    l Ce

    rtific

    ado <

    C>.

    06

    Nota

    *de

    linea

    to ne

    l <A>

    e giu

    dicato

    posit

    ivame

    nte

    da sec

    ondo

    il Ce

    rtific

    ato .07

    ™Ë

    Ì›ˆ

    ÛË *

    fiˆ˜

    ηı

    ÔÚ›˙Â

    Ù·È Û

    ÙÔ <

    A> Î

    ·È ÎÚ

    ›ÓÂÙ·

    È ıÂÙ

    Èο

    ·fi

    ÙÔ <

    B> Û

    ‡Ìʈ

    Ó· Ì

    Â ÙÔ

    ¶ÈÛÙ

    ÔÔÈË

    ÙÈÎfi

    .

    08

    Nota

    *tal

    como

    estab

    elecid

    o em

    e

    com

    o pare

    cer

    posit

    ivo de

    d

    e aco

    rdo co

    m o C

    ertifi

    cado

    .

    09

    Прим

    ечан

    ие *

    как у

    каза

    но в

    и в со

    отве

    тств

    ии с

    поло

    жите

    льны

    м ре

    шени

    ем <

    B> со

    глас

    но

    Свид

    етел

    ьств

    у <C>

    .10

    Be

    mærk

    *so

    m an

    ført i

    o

    g pos

    itivt v

    urdere

    t af <

    B> i

    henh

    old til

    Cer

    tifika

    t <C>

    .

    11

    Infor

    matio

    n *en

    ligt <

    A> oc

    h god

    känts

    av enli

    gt Ce

    rtifik

    atet <

    C>.

    12

    Merk

    *so

    m de

    t frem

    komm

    er i <

    A> og

    gjen

    nom

    posit

    iv be

    dømm

    else a

    v <B>

    ifølge

    Ser

    tifika

    t <C>

    .13

    Hu

    om *

    jotka

    on es

    itetty

    asiak

    irjass

    a <A>

    ja jo

    tka on

    hyvä

    ksyn

    yt Se

    rtifik

    aatin

    m

    ukais

    esti.

    14

    Pozn

    ámka

    *jak

    bylo

    uved

    eno v

    a

    pozit

    ivně z

    jištěn

    o <B>

    v so

    uladu

    s os

    vědč

    ením

    .

    15

    Napo

    mena

    *ka

    ko je

    izlož

    eno u

    i

    pozit

    ivno o

    cijen

    jeno o

    d str

    ane <

    B> pr

    ema C

    ertif

    ikatu

    .

    16

    Megje

    gyzé

    s *a(

    z) alap

    ján, a

    (z) iga

    zolta

    a me

    gfelel

    ést,

    a(z)

    t

    anús

    ítván

    y sze

    rint.

    17

    Uwag

    a *zg

    odnie

    z do

    kume

    ntacją

    ,

    pozy

    tywną

    opini

    ą i Ś

    wiad

    ectw

    em .18

    No

    tă *

    aşa c

    um es

    te sta

    bilit î

    n <A>

    şi ap

    recia

    t poz

    itiv

    de în c

    onfor

    mitat

    e cu C

    ertif

    icatu

    l <C>

    .19

    Op

    omba

    *ko

    t je do

    ločen

    o v in o

    dobr

    eno s

    stra

    ni v

    sklad

    u s ce

    rtifik

    atom

    .

    20

    Märk

    us *

    nagu

    on nä

    idatud

    doku

    mend

    is ja h

    eaks

    kii

    detud

    j

    ärgi

    vasta

    valt s

    ertif

    ikaad

    ile .

    21

    Забе

    лежк

    а *ка

    кто е

    изло

    жено

    в и о

    цене

    но

    поло

    жите

    лно о

    т <B>

    съгл

    асно

    ртиф

    икат

    а <C>

    .22

    Pa

    staba

    *ka

    ip nu

    statyt

    a <A>

    ir ka

    ip tei

    giama

    i nus

    pręs

    ta pa

    gal S

    ertif

    ikatą

    .

    23

    Piez

    īmes

    *kā

    norā

    dīts <

    A> un

    atbil

    stoši

    p

    ozitīv

    ajam

    vērtē

    jumam

    sask

    aņā a

    r ser

    tifikā

    tu .24

    Po

    znám

    ka *

    ako b

    olo uv

    eden

    é v a po

    zitívn

    e zist

    ené <

    B> v

    súlad

    e s o

    sved

    čením

    .

    25

    Not *

    ‘d

    a be

    lirtild

    iği g

    ibi v

    e Se

    rtifik

    asın

    agö

    re

    tara

    fında

    n olu

    mlu

    olara

    kde

    ğerle

    ndiril

    diği g

    ibi.

    DA

    IKIN

    .TC

    F.02

    4D10

    /01-

    2009

    TN

    O

    0510

    2601

    01

    EN

    6033

    5-2-

    40,

    3PW40917-2B

    Jean

    -Pie

    rre

    Beu

    selin

    ckD

    irect

    orO

    sten

    d, 3

    rd o

    f Oct

    ober

    201

    1

    Low

    Vol

    tage

    200

    6/95

    /EC

    Ele

    ctro

    mag

    netic

    Com

    patib

    ility

    200

    4/10

    8/E

    C*

    BS

    VQ

    100P

    8V1B

    *, B

    SV

    Q16

    0P8V

    1B*,

    BS

    VQ

    250P

    8V1B

    *,* =

    ,

    , 1,

    2, 3

    , ...,

    9

    01 a

    dec

    lares

    unde

    r its s

    ole re

    spon

    sibilit

    y tha

    t the a

    ir con

    dition

    ing eq

    uipme

    nt to

    which

    this

    decla

    ration

    relat

    es:

    02 d

    erkl

    ärt a

    uf se

    ine al

    leinig

    e Vera

    ntwor

    tung d

    ass d

    ie Au

    srüstu

    ng de

    r Klim

    agerä

    te für

    die d

    iese E

    rklär

    ung b

    estim

    mt is

    t:03

    f d

    éclar

    e sou

    s sa s

    eule

    respo

    nsab

    ilité q

    ue l'é

    quipe

    ment

    d'air c

    ondit

    ionné

    visé

    s par

    la pré

    sente

    décla

    ration

    :04

    l ve

    rklaa

    rt hie

    rbij o

    p eige

    n exc

    lusiev

    e vera

    ntwoo

    rdelijk

    heid

    dat d

    e airc

    ondit

    ioning

    appa

    ratuu

    r waa

    rop de

    ze ve

    rklar

    ing be

    trekk

    ing he

    eft:

    05 e

    dec

    lara b

    ajo su

    única

    resp

    onsa

    bilida

    d que

    el eq

    uipo d

    e aire

    acon

    dicion

    ado a

    l que

    hace

    refer

    encia

    la de

    clarac

    ión:

    06 i

    dich

    iara s

    otto l

    a prop

    ria re

    spon

    sabil

    ità ch

    e gli a

    ppare

    cchi

    di co

    ndizi

    onam

    ento

    a cui

    è rife

    rita qu

    esta

    dichia

    razion

    e:07

    g ‰

    ËÏÒÓ

    ÂÈ ÌÂ

    ·Ô

    ÎÏÂÈÛ

    ÙÈ΋

    Ù˘

    ¢ı‡

    ÓË fi

    ÙÈ Ô

    ÂÍÔ

    ÏÈÛÌfi

    ˜ Ùˆ

    Ó ÎÏ

    ÈÌ·ÙÈÛ

    ÙÈÎÒÓ

    Û˘Û

    ΢Ò

    Ó ÛÙ

    · Ô

    Ô›· ·

    ӷʤ

    ÚÂÙ·

    È Ë

    ·ÚÔ‡

    Û· ‰

    ‹ÏˆÛ

    Ë:08

    p d

    eclar

    a sob

    sua e

    xclus

    iva re

    spon

    sabil

    idade

    que o

    s equ

    ipame

    ntos d

    e ar c

    ondic

    ionad

    o a qu

    e esta

    decla

    ração

    se re

    fere:

    09 u

    заяв

    ляет,

    искл

    ючит

    ельн

    о под

    свою

    отве

    тстве

    ннос

    ть, чт

    о обо

    рудов

    ание

    для к

    онди

    цион

    иров

    ания

    возд

    уха, к

    кото

    рому

    отно

    сится

    насто

    ящее

    заяв

    лени

    е:10

    q e

    rklær

    er un

    der e

    nean

    svar,

    at ud

    styret

    til kl

    imare

    guler

    ing, s

    om de

    nne d

    eklar

    ation

    vedrø

    rer:

    11 s

    dek

    larere

    r i eg

    ensk

    ap av

    huvu

    dans

    varig

    , att l

    uftko

    nditio

    nerin

    gsutr

    ustni

    ngen

    som

    berör

    s av d

    enna

    dekla

    ration

    inne

    bär a

    tt:12

    n e

    rklær

    er et

    fullst

    endig

    ansv

    ar for

    at de

    t luftk

    ondis

    joner

    ingsu

    tstyr

    som

    berø

    res av

    denn

    e dek

    laras

    jon, in

    nebæ

    rer at

    :13

    j ilm

    oittaa

    yksin

    omaa

    n oma

    lla va

    stuull

    aan,

    että t

    ämän

    ilmoit

    ukse

    n tar

    koitta

    mat il

    masto

    intila

    itteet:

    14 c

    pro

    hlašu

    je ve

    své p

    lné od

    pově

    dnos

    ti, že

    klim

    atiza

    ční z

    aříze

    ní, k

    nimž s

    e toto

    proh

    lášen

    í vzta

    huje:

    15 y

    izjav

    ljuje

    pod i

    sklju

    čivo v

    lastito

    m od

    govo

    rnoš

    ću da

    opre

    ma za

    klim

    atiza

    ciju n

    a koju

    se ov

    a izja

    va od

    nosi:

    16 h

    telje

    s fele

    lőssé

    ge tu

    datáb

    an ki

    jelen

    ti, ho

    gy a

    klíma

    bere

    ndez

    ések

    , mely

    ekre

    e ny

    ilatko

    zat v

    onatk

    ozik:

    17 m

    dek

    laruje

    na w

    łasną

    i wyłą

    czną

    odpo

    wied

    zialno

    ść, ż

    e klim

    atyza

    tory,

    któryc

    h doty

    czy n

    iniejs

    za de

    klara

    cja:

    18 r

    dec

    lară p

    e pro

    prie

    răsp

    unde

    re că

    echip

    amen

    tele d

    e aer

    cond

    iţiona

    t la ca

    re se

    refer

    ă ace

    astă

    decla

    raţie

    :19

    o z

    vso o

    dgov

    orno

    stjo i

    zjavlj

    a, da

    je op

    rema

    klim

    atskih

    napr

    av, n

    a kate

    ro se

    izjav

    a nan

    aša:

    20 x

    kinn

    itab o

    ma tä

    ieliku

    l vas

    tutus

    el, et

    käes

    oleva

    dekla

    ratsi

    ooni

    alla k

    uuluv

    kliim

    asea

    dmete

    varu

    stus:

    21 b

    дек

    лари

    ра на

    своя

    отго

    ворн

    ост,

    че об

    оруд

    ване

    то за

    клим

    атич

    на ин

    стал

    ация

    , за к

    оето

    се от

    нася

    тази

    дек

    лара

    ция:

    22 t

    visi

    ška s

    avo a

    tsako

    mybe

    skelb

    ia, ka

    d oro

    kond

    icion

    avim

    o įra

    nga,

    kuria

    i taiko

    ma ši

    dekla

    racij

    a:23

    v a

    r piln

    u atbi

    ldību

    aplie

    cina,

    ka tā

    lāk uz

    skait

    ītās g

    aisa k

    ondic

    ionēš

    anas

    iekā

    rtas,

    uz ku

    riem

    attiec

    as šī

    dekla

    rācij

    a:24

    k v

    yhlas

    uje na

    vlas

    tnú zo

    dpov

    edno

    sť, že

    klim

    atiza

    čné z

    ariad

    enie,

    na kt

    oré s

    a vzťa

    huje

    toto v

    yhlás

    enie:

    25

    w ta

    mam

    en ke

    ndi s

    orum

    luluğ

    unda

    olm

    ak ü

    zere

    bu

    bildir

    inin

    ilgili

    olduğ

    u kli

    ma

    dona

    nım

    ının

    aşa

    ğıda

    ki gib

    i oldu

    ğunu

    bey

    an e

    der:

  • BSVQ100P8V1BBSVQ160P8V1BBSVQ250P8V1B

    VRVIII SYSTEM Air Conditioners Installation manual

    CONTENTS1. SAFETY PRECAUTIONS.............................................................................................. 1

    2. BEFORE INSTALLATION ............................................................................................. 3

    3. SELECTING INSTALLATION SITE............................................................................... 4

    4. PREPARATIONS BEFORE INSTALLATION ................................................................ 5

    5. BS UNIT INSTALLATION.............................................................................................. 6

    6. REFRIGERANT PIPING WORK ................................................................................... 7

    7. ELECTRIC WIRING WORK ........................................................................................ 12

    8. INITIAL SETTING........................................................................................................ 15

    9. TEST OPERATION ..................................................................................................... 15

    10. WIRING DIAGRAM ..................................................................................................... 16

    1. SAFETY PRECAUTIONSPlease read these “SAFETY PRECAUTIONS” carefully before installing air conditioning unit and be sure to install it correctly. After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air conditioner and take care of it with the aid of the operation manual. Ask the customer to store the installation manual along with the operation manual for future reference.This air conditioner comes under the term “appliances not accessible to the general public”.

    VRV System is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

    Meaning of WARNING and CAUTION notices

    WARNING ........ Failure to follow these instructions properly may result in personal injury or loss of life.

    CAUTION ......... Failure to observe these instructions properly may result in property damage or per-sonal injury, which may be serious depending on the circumstances.

    WARNING• Ask your dealer or qualified personnel to carry out installation work.

    Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.

    • Install the air conditioner in accordance with the instructions in this installation manual.Improper installation may result in water leakage, electric shocks or fire.

    • When installing the unit in a small room, take measures against to keep refrigerant concentration from exceeding allowable safety limits in the event of refrigerant leakage.Contact the place of purchase for more information. Excessive refrigerant in a closed ambient can lead to oxygen deficiency.

    • Be sure to use only the specified accessories and parts for installation work.Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.

    • Install the air conditioner on a foundation strong enough to withstand the weight of the unit.A foundation of insufficient strength may result in the equipment falling and causing injury.

    • Carry out the specified installation work after taking into account strong winds, typhoons or earthquakes.Failure to do so during installation work may result in the unit falling and causing accidents.

    English 1

  • • Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried out by qualified personnel according to local laws and regulations and this installation manual.An insufficient power supply capacity or improper electrical construction may lead to electric shocks or fire.

    • Be sure to earth the air conditioner.Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks or fire.A high surge current from lightning or other sources may cause damage to the air conditioner.

    • Be sure to install an earth leakage breaker.Failure to install an earth leakage breaker may result in electric shocks or fire.

    • Be sure to switch off the unit before touching any electrical parts.• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal

    connections or wires.Improper connections or securing of wires may result in abnormal heat build-up or fire.

    • When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires so that the EL. COMPO. BOX lid can be securely fastened.Improper positioning of the EL. COMPO. BOX lid may result in electric shocks, fire or the terminals over-heating.

    • If refrigerant gas leaks during installation, ventilate the area immediately.Toxic gas may be produced if the refrigerant gas comes into contact with fire.

    • After completing installation, check for refrigerant gas leakage.Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.

    • Do not directly touch refrigerant that has leaked from refrigerant pipes or other areas, as there is a danger of frostbite.

    CAUTION• Install the BS units, power cord and connecting wires at least 1 meter away from televisions or radios to

    prevent picture interference and noise. (Depending on the incoming signal strength, a distance of 1 meter may not be sufficient to eliminate noise.)

    • Remote controller (wireless kit) transmitting distance can be shorter than expected in rooms with electronic fluorescent lamps (inverter or rapid start types). Install the BS unit as far away from fluorescent lamps as possible.

    • Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals. Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.

    • Do not install the air conditioner in the following locations:1. Where there is a high concentration of mineral oil spray or vapour (e.g. a kitchen).

    Plastic parts will deteriorate, parts may fall off and water leakage could result.2. Where corrosive gas, such as sulphurous acid gas, is produced.

    Corroding of copper pipes or soldered parts may result in refrigerant leakage.3. Near machinery emitting electromagnetic radiation.

    Electromagnetic radiation may disturb the operation of the control system and result in a malfunction of the unit.

    4. Where flammable gas may leak, where there is carbon fibre or ignitable dust suspensions in the air, or where volatile flammables such as paint thinner or gasoline are handled. Operating the unit in such conditions may result in fire.

    5. Do not use in areas where the air is salty, such as along seacoasts, in factories or other areas with sig-nificant voltage fluctuations, or in automobiles and watercraft.Doing so could result in a malfunction.

    2 English

  • CAUTIONThe refrigerant R410A requires that strict precautions be observed for keeping the system clean, dry and tightly sealed.Clean and dryStrict measures must be taken to keep impurities (including SUNISO oil and other mineral oils as well as moisture) out of the system.Tightly sealedR410A contains no chlorine, does not destroy the ozone layer and so does not reduce the earth’s pro-tection against harmful ultraviolet radiation. R410A will contribute only slightly to the greenhouse effect if released into the atmosphere. Therefore, sealing tightness is particularly important in installation.Carefully read the chapter “REFRIGERANT PIPING WORK” and strictly observe the correct proce-dures.

    2. BEFORE INSTALLATION

    2-1 CAUTION CONCERNING NEW REFRIGERANT SERIES• Since design pressure is 4.0 MPa or 40 bar (for R407C units: 3.3 MPa or 33 bar), the thickness of pipes

    must be greater than previously. Since R410A is a mixed refrigerant, the required additional refrigerant must be charged in its liquid state. (If the system is charged with refrigerant in its gaseous state, due to composition change, the system will not function normally.)The indoor/outdoor unit is designed for R410A. See the catalogue for indoor/outdoor unit models that can be connected. (Normal operation is not possible when connecting units that are originally designed for other refrigerants.

    2-2 PRECAUTIONS• Hold the unit by the Hanging brackets (4 points) when opening the box and moving it, and do not lift it hold-

    ing on to any other part especially the refrigerant piping.• About installation of outdoor and indoor unit, refer to the installation manual provided with the outdoor and

    the indoor unit.• This unit, both indoor and outdoor, is suitable for installation in a commercial and light industrial environment.

    If installed as a household appliance it could cause electromagnetic interference.

    2-3 ACCESSORIES

    Check the following accessories are included with your unit.

    NOTE• Do not throw away any of the accessories until installation is complete.

    〈BSVQ100 · 160P8V1B〉

    〈BSVQ250P8V1B〉

    Name1) Accessory pipes 1) Accessory pipes

    2) Clamp 3) Insulation tubeExplanation Document(BSVQ100 only) (BSVQ160 only)

    Quantity 1 pc. 1 pc. 1 pc. 2 pcs. 6 pcs. 10 pcs. 2 pcs. 3 pc. 1 copy

    Shape

    1)-1

    φ9.5

    1)-2

    φ15.9

    1)-1

    φ12.7

    1)-2

    φ15.9

    2)-1

    (Small)

    2)-2

    (Large)

    3)-1

    (Small)

    3)-2

    (Large)

    Installation manual

    Name 1) Accessory pipes 2) Clamp 3) Insulation tubeExplanation Document

    Quantity 1 pc. 2 pcs. 6 pcs. 10 pcs. 2 pcs. 2 pcs. 1 pc 1 copy

    Shape

    1)-1 1)-2 2)-1

    (Small)

    2)-2

    (Large)

    3)-1

    (Small)

    3)-2

    (Medium)

    3)-3

    (Large)

    Installation manual

    English 3

  • 2-4 COMBINATION• This BS unit is only for systems for Models REYQ-P.

    It cannot be connected to systems for Models REYQ-M.• For series of applicable indoor units, refer to the catalog or other literature.• Select the BS unit to fit the total capacity (sum of unit’s capacity) and max. number of the indoor units to be

    connected downstream. About indoor unit’s capacity, refer to the Table 2.

    Table 1

    Table 2

    * About indoor unit’s capacity for HRV type (VKM), refer to the Engineering data book.

    In case of the BS unit witch connect two FXCQ32M and two FXSQ40M.

    Total capacity = 31.25x2+40x2 = 142.5 → Select BSVQ160P8V1B

    2-5 CHECK ITEM• For the following items, take special care during construction and check after installation is finished.

    Completion check items

    Hand-over check items

    3. SELECTING INSTALLATION SITE

    The equipment is not intended for use in a potentially explosive atmosphere.Select an installation site where the following conditions are satisfied and that meets with your customer’s approval.• Where is resistible against weight of BS unit.• Locations where the wall is not significantly tilted.• Where sufficient clearance for maintenance and service can be ensured. (Refer to Fig. 1)• Locations where an inspection hole (Refer to Fig. 2) can be installed to EL. COMPO. BOX side (See Note).• Where the total piping length involving indoor unit and outdoor unit is below the allowable piping length.

    (See installation manual attached to outdoor unit.)

    Model Total capacity of all downstreem indoor units Max. number of all downstreem indoor units

    BSVQ100P8V1B A ≤ 100 5

    BSVQ160P8V1B 100 < A ≤ 160 8

    BSVQ250P8V1B 160 < A ≤ 250 8

    Capacity expressed as indoor unit’s model No. 20 25 32 40 50 63 80 100 125 200 250

    Indoor unit’s capacity (for use in computation) 20 25 31.25 40 50 62.5 80 100 125 200 250

    Check items Problems Check

    Are the BS units installed securely? Falling, vibration, and operating noise

    Have you performed a gas leak test? Does not cool or heat

    Is the insulation complete? (Refrigerant piping and pipe connection part) Water leaking

    Is the voltage the same as that listed on the unit’s nameplate? Does not operate/burnt out

    Are all the wiring and piping correct? Does not operate/burnt out

    Is the unit grounded? Dangers during electrical leak

    Is the thickness of the power cord as specified? Does not operate/burnt out

    Check items Check

    Did you close the EL. COMPO. BOX lid?

    Did you hand the operating manual and warranty card to the customer?

    4 English

  • Note: The EL. COMPO. BOX mounting surface can be changed.For information on how to change the mounting surface, refer to “5. BS UNIT INSTALLATION”.

    NOTES• Study if the installation location is strong enough to hold the weight of the unit, and if necessary reinforce

    the area with a beam or other member and then install suspension bolts. Use the suspension bolts to install the unit. (Refer to “4. PREPARATIONS BEFORE INSTALLATION”)

    • Install the BS unit and its power supply wiring and transmission wiring at least 1 meter away from televi-sions and radios to prevent image distortion and noise in those devices. Noise may still be introduced at this distance depending on the electromagnetic wave conditions.

    4. PREPARATIONS BEFORE INSTALLATIONRefer the figure 3 and install the suspension bolts and hanging brackets.

    〈Suspension bolts: For supporting the product〉• Use M8-M10 suspension bolts.• When holes are to be made anew, used embedded inserts and embedded foundation bolts. When holes

    are already provided, use hole-in-anchors or the like.Install the BS unit so that its weight can be withstood.

    〈Hanging bracket: For supporting the connection pipe〉• Be sure to support the connection piping around the unit using hanging brackets that are kept within

    1 meter of the body side surface. Hanging excessive weight on the BS unit hanging bracket could cause the unit to fall and injure someone.

    (mm)

    BS Unit NameBSVQ100PBSVQ160PBSVQ250P

    250 or more250 or more (*2)300 or more (*3)

    250 or more (*1)250 or more (*2)300 or more (*3)

    A B (*1) When using accessory pipes 1)-1, 2 (Refer to 6-5 PIPING CONNECTION), provide a service space of at least 300mm.

    (*2) When using accessory pipes 1)-1, 2 (Refer to 6-5 PIPING CONNECTION), provide a service space of at least 350mm.

    (*3) When using accessory pipes 1)-1, 2 (Refer to 6-5 PIPING CONNECTION), provide a service space of at least 400mm.

    A B

    Indoor unit side (2 pipes)

    (mm)

    Outdoor unit side (3 pipes) 65

    or

    mor

    e50

    or

    mor

    e

    BS unit proper top

    EL. COMPO. BOX

    Inspection hole 450

    (mm)

    Be sure to open this to the EL. COMPO. BOX side.

    Fig. 1Fig. 2

    428 219

    Hanging bracket

    Suspension bolt

    Long nut orturnbuckle

    Anchor

    1m or less 1m or less

    Unit proper

    Note: All the above parts are part to be procured in the field.

    Fig. 3

    English 5

  • 5. BS UNIT INSTALLATIONUse only accessories and parts which are of the designated specification when installing.

    (1) When necessary, use the following procedure to change the EL. COMPO. BOX mounting surface. (Refer to Fig. 4)1) Remove the EL. COMPO. BOX lid. (2 screws)2) Remove the EL. COMPO. BOX. (2 screws)3) Remove the top panel. (4 screws)4) Remove the coil cover. (1 screw)5) Change the pull out direction of the wire (motorized valve coil) between the body and the EL. COMPO.

    BOX.6) Rotate the coil cover 180 degrees and attach it.7) Turn the top panel around 180 degrees and attach it.8) Attach the EL. COMPO. BOX.9) Attach the EL. COMPO. BOX lid.

    (2) Attach the hooks to the suspension bolts.Be sure to use the nuts (M8 or M10: 3 pcs, 4 locations) and washers (For M8: Outside diameter dimension 24 to 28mm, For M10: Outside diameter 30 to 34mm: 2 pcs, 4 locations) (field supply) from both the top and bottom sides of the hanging bracket and make sure they are tightened correctly.

    NOTES• The BS unit has a top and a bottom, so install it so that the diagonal

    lines in the figure 4 are where the top is.(Failing to do so may prevent the unit from operating properly and increase the volume of the operating noise.)

    Washer (Field supply) Nut

    (Field supply)

    BS unit proper

    Hanging bracket

    10 – 15mm

    Nut(Double nut)(Field supply)

    Suspension bolt(Field supply)

    EL. COMPO. BOX lid

    Coil cover

    Top Panel

    EL. COMPO. BOX

    5)-2(Move the EL. COMPO. BOX)

    1)

    1)

    2)

    4), 6)

    3), 7)

    3), 7)

    3), 7)

    3), 7)

    (Rotate 180 degrees)6)

    7)(Rotate 180 degrees)

    2)

    9)

    9)

    8)

    8)

    4)

    2)

    [Before change 5)-1]

    [After change 5)-3]

    EL. COMPO. BOX

    EL. COMPO. BOX

    Remove the wire from the wire clip.

    Pass the wire through the wire clip.Fig. 4

    6 English

  • 6. REFRIGERANT PIPING WORK• For instruction for installing piping between the outdoor unit and BS unit, selecting a refrigerant branch kit,

    and installing piping between the refrigerant branch kit and the indoor unit, refer to the installation manual and equipment design materials included with the outdoor unit.

    • Before beginning the work, always check to make sure the type of refrigerant used is R410A. (The unit will not operate correctly with a different type of refrigerant.)

    • Insulate all of the piping including the liquid pipes, HP/LP gas pipes, suction gas pipes, gas pipes, equalizer pipes (piping between outdoor units when an outdoor multi-unit system), and the pipe connections for these. Not insulting these pipes could result in water leaks or burns. In particular, suction gas flows in the HP/LP gas piping during full cooling operation, so the same amount of insulation as used for the suction gas piping is required. In addition, high-pressure gas flows in the HP/LP gas piping and gas piping, so use insulation that can withstand more than 120˚C.

    • Reinforce the insulation material when necessary for the installation environment. Refer to the following as a guideline.• For 30˚C, RH75% to 80%: Thickness at least 15mm• For 30˚C, over RH80%: Thickness at least 20mmIf not reinforced, condensation could form on the surface of the insulation. For details, refer to the Engi-neering data book.

    NOTES• This product only uses the new refrigerant (R410A). Be sure to use the special pipe cutters for R410A, dur-

    ing installation.• Make sure that nothing besides the specified refrigerant, such as air, gets into the refrigerant piping.• If refrigerant gas leaks during the work, ventilate the area. (The outdoor units are filled with refrigerant.)

    6-1 PIPING MATERIAL SELECTION• Use only pipes which are clean inside and outside and which do not accumulate harmful sulfur, oxidants,

    dirt, cutting oils, moisture, or other contamination. (Foreign materials inside pipes including oils for fabrica-tion must be 30mg/10m or less.)

    • Use the following items for the refrigerant piping.Material: Jointless phosphor-deoxidized copper pipeSize: See “Example of connection” to determine the correct size.Thickness: Select a thickness for the refrigerant piping which complies with national and local laws.For R410A, the design pressure is 4.0 MPa (40bar).The minimum thickness of piping according to Japan’s High-Pressure Gas Safety Law (as of January 2003) is shown below.Temper grade (O type, 1/2H type) in the table indicate the material types specified in JIS H 3300.

    (unit: mm)

    (unit: mm)

    • For information regarding the piping allowable maximum length, allowable height difference, and allowable length after a branch, refer to the installation manual that came with the outdoor unit or Engineering data book.

    • The refrigerant branch kit (sold separately) is required for piping branches. For information on how to select a refrigerant branch kit, refer to the Installation Manual that came with the outdoor unit or Engineering data book.

    Temper grade O type

    outer diameter φ6.4 φ9.5 φ12.7 φ15.9

    smallest thickness 0.80 0.80 0.80 0.99

    Temper grade 1/2H type

    outer diameter φ19.1 φ22.2 φ25.4 φ28.6 φ31.8 φ34.9 φ38.1 φ41.3

    smallest thickness 0.80 0.80 0.88 0.99 1.10 1.21 1.32 1.43

    English 7

  • 6-2 PROTECTION AGAINST CONTAMINATION WHEN INSTALLING PIPESProtect the piping to prevent moisture, dirt, dust, etc. from entering the piping.

    NOTEExercise special caution to prevent dirt or dust when passing piping through holes in walls and when passing pipe edges to the exterior.

    6-3 PIPING CONNECTION WORK PRECAUTIONS• When brazing refrigerant piping, begin working after replacing the nitrogen (*1) or perform brazing while

    nitrogen is flowing in the refrigerant piping (*2) (Refer to Fig. 5), and at the end made the indoor unit and BS unit flare or flange connections.(*1) For details on nitrogen replacement, see the “VRV Installation Manual” (available at any Daikin

    dealer).(*2) The pressure regulator for the nitrogen released when doing the brazing should be set to about

    0.02 MPa (0.2kg/cm2:Enough to feel a slight breeze on your cheek).

    NOTES• Do not use an anti-oxidizing agent when brazing the piping. Residual debris could clog the piping or cause

    parts to malfunction.• Do not use a flux when brazing the refrigerant pipe joints.

    Using a chlorine flux may cause the pipes to corrode, and if it contains fluoride it may cause the refrigerant lubricant to deteriorate, adversely affecting the refrigerant piping system.Use phosphor copper brazing (BCuP-2: JIS Z 3264/B-Cu93P-710/795: ISO 3677) which does not require flux.

    6-4 PIPING SIZE SELECTIONFrom Example of connection 1 and 2 below and Table 1, 2, select the piping size between the outdoor unit (refrigerant branch kit) and BS unit, and between the BS unit and the indoor unit (refrigerant branch kit).

    Example of connection 1: When 1 indoor unit is connected downstream from the BS unit

    Place Installation period Protection method

    OutdoorMore than a month Pinch the pipe

    Less than a monthPinch or tape the pipe

    Indoor Regardless of the period

    Refrigerant pipingValve

    Pressure-reducing valve

    Part to be brazed Taping

    NitrogenNitrogen

    Fig. 5

    To refrigerant branch kit or outdoor unit

    *Suction gas pipe

    Gas pipe

    Indoor unit

    Liquid pipe

    HP/LP gas pipe

    Liquid pipe

    Determine using Table 1 based on the total capacity of the indoor units connected downstream.

    Select from Table 2 depending on the capacity type of the indoor unit.

    BSunit

    8 English

  • Example of connection 2: When there is a branch downstream from the BS unit

    Table 1 Indoor unit total capacity and pipe size

    Table 2 Indoor unit connection pipe size

    * The BS unit downstream connection pipe sizes are shown below. If the pipe diameter differs from that of the indoor unit connection pipe size selected from Table 2, follow the instructions in “6-5 PIPING CONNEC-TION” and use the included pipe to make the connection.

    Table 3 BS unit connection pipe size

    6-5 PIPING CONNECTIONFollow the connection example below and connect the site piping.

    (mm)

    Total capacity of indoor units(Q)

    Piping size (outer diameter x minimum thickness)

    Upstream Downstream

    Suction gas pipe HP/LP gas pipe Liquid pipe Gas pipe Liquid pipe

    Q < 150 φ15.9x0.99 φ12.7x0.80

    φ9.5x0.80

    φ15.9x0.99

    φ9.5x0.80150 ≤ Q < 200 φ19.1x0.80 φ15.9x0.99 φ19.1x0.80

    200 ≤ Q ≤ 250 φ22.2x0.80 φ19.1x0.80 φ22.2x0.80

    (mm)

    Capacity type of indoor unitsPiping size (outer diameter x minimum thickness)

    Gas pipe Liquid pipe

    20, 25, 32, 40, 50 φ12.7x0.80 φ6.4x0.80

    63, 80, 100, 125 φ15.9x0.99

    φ9.5x0.80200 φ19.1x0.80

    250 φ22.2x0.80

    (mm)

    BS unitPiping size (outer diameter)

    Gas pipe Liquid pipe

    BSVQ100Pφ15.9

    φ9.5BSVQ160P

    BSVQ250P φ22.2

    Indoor unit Indoor unit Indoor unit

    Gas pipe

    Liquid pipe

    Determine using Table 1 based on the total capacity of the indoor units connected downstream.

    For information on selecting the size of piping between the refrigerant branch kits and between a refrigerant branch kit and the indoor unit, refer to the Installation Manual that came with the outdoor unit or Engineering data book.

    To refrigerant branch kit or outdoor unit

    Suction gas pipe

    HP/LP gas pipe

    Liquid pipe

    BSunit

    Refrigerant branch kit

    Suction gas pipe (Site piping)

    HP/LP gas pipe (Site piping)

    Gas pipe (Site piping)

    Liquid pipe (Site piping)Liquid pipe (Site piping)

    BS unit(Top)

    BSVQ100P type

    When the downstream indoor unit total capacity is 100 or less and when one indoor unit with a capacity of 63 to 100 is connected downstream.

    English 9

  • When one indoor unit with a capacity of 20 to 50 is connected downstream

    Accessory pipes 1)-2

    Accessory pipes 1)-1

    Suction gas pipe (Site piping)

    HP/LP gas pipe (Site piping)

    Liquid pipe (Site piping)

    Gas pipe (Site piping)

    Liquid pipe (Site piping)BS unit(Top)

    Suction gas pipe (Site piping)

    HP/LP gas pipe (Site piping)

    Gas pipe (Site piping)

    Liquid pipe (Site piping)Liquid pipe (Site piping)

    BS unit(Top)

    BSVQ160P type

    When the downstream indoor unit total capacity is more than 100 but less than 150 and when one indoor unit with a capacity of 125 is connected downstream.

    When the downstream indoor unit total capacity is 150 or more but 160 or less

    Accessory pipes 1)-2

    Suction gas pipe (Site piping)

    HP/LP gas pipe (Site piping)

    Liquid pipe (Site piping)

    Gas pipe (Site piping)

    Liquid pipe (Site piping)BS unit(Top)

    Accessory pipes 1)-2

    Accessory pipes 1)-1

    Gas pipe (Site piping)

    Liquid pipe (Site piping)BS unit(Top)

    Suction gas pipe (Site piping)

    HP/LP gas pipe (Site piping)

    Liquid pipe (Site piping)

    Accessory pipes 1)-2 Accessory pipes 1)-2

    Accessory pipes 1)-1

    BSVQ250P type

    When the downstream indoor unit total capacity is more than 160 but less than 200

    When the downstream indoor unit total capacity is 200 or more but 250 or less and when one indoor unit with a capacity of 250 is connected downstream.

    Suction gas pipe (Site piping)

    HP/LP gas pipe (Site piping)

    Liquid pipe (Site piping)

    Gas pipe (Site piping)

    Liquid pipe (Site piping)BS unit(Top)

    When one indoor unit with a capacity of 200 is connected downstream

    Suction gas pipe (Site piping)

    HP/LP gas pipe (Site piping)

    Liquid pipe (Site piping)

    Gas pipe (Site piping)

    Liquid pipe (Site piping)BS unit(Top)

    Accessory pipes 1)-2

    10 English

  • 6-6 PIPING INSULATION• After the gas leak inspection is completed, refer to the following figures and use the included insulation tube

    3) and clamps 2) to apply the insulation.

    NOTES• Insulate all of the piping including the liquid pipes, HP/LP gas pipes, suction gas pipes, gas pipes, and the

    pipe connections for these. Not insulting these pipes could result in water leaks or burns. In particular, suc-tion gas flows in the HP/LP gas pipes during full cooling operation, so the same amount of insulation as used for the suction gas pipes is required. In addition, high-pressure gas flows in the HP/LP gas pipes and gas pipes, so use insulation that can withstand more than 120˚C.

    • When reinforcing the insulation material for the installation environment, also reinforce the insulation on the piping protruding from the unit and on the pipe connections. Locally purchase the insulation required for the reinforcement work.

    Insulation Installation Precautions

    1. Seal so that air cannot be in and out of the end.2. Do not over tighten the clamp so as to maintain the insulation thickness.3. Be sure to attach the insulation (field supply) with the seams facing up.

    (See figure at right.)

    BSVQ100 · 160P type BSVQ250P type

    BS unit BS unit

    Clamp 2)-2 (Accessory) Clamp 2)-2 (Accessory)Insulation tube 3)-2(Accessory)

    Insulation tube 3)-2(Accessory)

    Insulation tube 3)-2(Accessory)

    Insulation tube 3)-1(Accessory)

    Insulation tube 3)-2(Accessory)

    Insulation tube 3)-1(Accessory)

    Insulation tube 3)-2(Accessory)

    Insulation tube 3)-1(Accessory)

    Insulation tube 3)-1(Accessory)

    Insulation tube 3)-3(Accessory)

    Suction gas pipe (Note 1) Gas pipe

    (Note 1)

    Liquid pipe

    Gas pipe (Note 2)

    Liquid pipe

    HP/LP gas pipe (Note 1)

    Liquid pipe

    Suction gas pipe (Note 2)HP/LP gas pipe (Note 1)

    Liquid pipe

    Clamp 2)-2 (Accessory) Clamp 2)-2 (Accessory)

    Insulation Attachment Instructions

    Piping insulation(Product piping side)

    Pipe connection

    Insulation material (Field supply)

    Seal the connection.Piping insulation(Site piping side)

    (1) Attach the included insulation.

    (2) Seal (3) Use the clamps (accessory) to hold both ends.

    Note 1: For suction gas pipes, HP/LP gas pipes, and gas pipes, after attaching the included insulation tube, wrap more insulation (field supply) around the connections.

    Note 2: For Model Q250, wrap sealing material (field supply) around the insulation tube 3)-2 BS unit side and site piping side connections to seal them.

    Main unit Main unit

    Insulation tube 3)-2(Accessory)

    Attach facing upSeam

    English 11

  • 7. ELECTRIC WIRING WORK

    7-1 GENERAL INSTRUCTIONS• All wiring must be performed by an authorized electrician.• All field supplied parts and materials, electric works must conform to local codes.• Always ground wires. (In accordance with national regulations of the pertinent country.)• Always turn off the power before performing the electric wire installation work.• Follow the “WIRING DIAGRAM” attached to the unit body to wire the outdoor unit and indoor units.• Properly connect wire of the specified wire type and copper thickness. Also use the included clamp to avoid

    applying excessive force to the terminal (field wire, ground wire).• Do no let the ground wire should come in contact with gas pipes, water pipes, lighting rods, or telephone

    ground wires.• Gas pipes: gas leaks can cause explosions and fire.• Water pipes: cannot be grounded if hard vinyl pipes are used.• Telephone ground and lightning rods: the ground potential when struck by lightning gets extremely high.

    • A circuit breaker capable of shutting down the power supply to the entire system must be installed.• This system consists of multiple BS units. Mark each BS unit as unit A, unit B . . . , and be sure the terminal

    board wiring to the outdoor unit and indoor unit are properly matched. If wiring and piping between the out-door unit, BS unit and an indoor unit are mismatched, the system may cause a malfunction.

    • Do not turn on the power supply (branch switches, overload interrupters) until all other work is done.

    7-2 EXAMPLE FOR THE WHOLE SYSTEM

    7-3 POWER CIRCUIT, SAFETY DEVICE AND CABLE REQUIREMENTS• A power circuit (Refer to Table 3) must be provided for connection of the unit. This circuit must be protected with the

    required safety devices, i.e. a main switch, a slow blow fuse on each phase and an earth leakage circuit breaker.• A main switch or other means for disconnection, having a contact separation in all poles, must be incorporated in

    the fixed wiring in accordance with relevant local and national legislation.• When using residual current operated circuit breakers, be sure to use a high-speed type (0.1 second or

    less) 30mA rated residual operating current.• Use copper conductors only.• Use insulated wire for the power cord.• Select the power supply cable type and size in accordance with relevant local and national regulations.• Specifications for local wiring are in compliance with IEC60245.• Use wire type H05VV-U3G for power supply wiring. And the size must comply with local codes.• Use vinyl cord with sheath or cable (2 wire) of 0.75-1.25mm

    2 for transmission wiring.

    Table 3

    MCA: Min. Circuit Amps (A); MFA: Max. Fuse Amps (A)

    Units Power supplyModel Type Hz Voltage Min. Max. MCA MFA

    BSVQ100PBSVQ160PBSVQ250P

    V1 50220

    198 264 0.1 15230240

    Power supply wiring

    Transmission wiring

    Switch

    Fuse

    Outdoor unitPower supply

    Power supply

    Main switch

    Main switch

    BS unit

    Indoor unit

    Remote controller

    Cooling/Heating selectable indoor unit

    Cooling-dedicated indoor unit

    12 English

  • NOTES• The above Table 3 of Electrical Characteristics refers to one BS unit.• See the Engineering data book for other details.

    7-4 WIRING EXAMPLE• Here is shown a wiring example for one system transmission wiring.• Connect terminals F1 and F2 (TO IN/D UNIT) on the control PCB (A1P) in the outdoor unit EL. COMPO.

    BOX and terminals F1 and F2 (TO OUT/D UNIT) of the control PCB (A1P) of the first BS unit A.

    NOTES1. Connect cooling-dedicated air conditioners to terminals F1 and F2 (TO OUT/D UNIT) of the final BS unit.2. Use 2-core wire for the transmission wiring. Using a multi-core wire with 3 or more cores when two or more

    indoor units are used at once could cause abnormal stoppage. (Only use 3-core wire in the COOL/HEAT SELECTOR.)

    3. Absolutely do not connect the power supply wiring to the transmission wiring terminal block. Doing so could damage the entire system.

    4. For the transmission wiring, use wire that is within the following ranges. Exceeding these limits could cause a transmission error.(1) Between an outdoor unit and BS unit,

    Between a BS unit and indoor unit, andBetween a BS unit and BS unit

    Maximum wiring length: 1000m or lessTotal wiring length: 2000 or lessBranch point max: 16 branch points

    (2) Between a BS unit and COOL/HEAT SELECTORMaximum wiring length: 500m or less

    7-5 WIRING CONNECTIONSRemove the EL. COMPO. BOX lid on the side and follow the directions to connect the wires.

    〈Transmission wiring〉Remove the EL. COMPO. BOX lid and connect the wires to F1 and F2 (TO IN/D UNIT) and F1 and F2 (TO OUT/D UNIT) transmission wiring terminals (control PCB (A1P)).At this time, pass the wiring into the unit through the wiring through hole (left) and use the included clamps 2) to securely hold the wires (in 2 places).

    〈Power supply wiring and ground wire〉Remove the EL. COMPO. BOX lid and connect the power supply wiring to the power terminal block (X1M).Also connect the ground wire to the ground wire terminal. Pass both the power supply wire and the ground wire together through the wire through hole (right) and into the EL. COMPO. BOX and use the included clamps 2) to securely hold the wires (in 2 places).Be sure to wire the ground wire so that comes out of the slit in the cup washer.(Not doing so could cause insufficient ground wire contact and causing the wire not to function as a ground.)

    F1F2

    F1

    F1 F2 F1 F2 F1 F2 F1 F2 F1 F2

    F1 F2

    F2 F1 F2

    F1F2

    F1 F2 F1 F2 F1 F2 F1 F2

    A

    A B C A B C A B C

    B

    C

    A

    B

    C

    A

    B

    C

    (1)

    (1)

    (1) (1)

    (1) (1) (1)

    (1)(1)

    (2)(2)(2)

    Absolutely do not connect the power supply wiring.

    Transmission wiringUse 2-core wires.(There is no polarity.)

    COOL/HEAT SELECTOR wiringUse 3-core wires. (There is polarity. Match the terminal numbers.)

    Cooling/Heating selectable indoor unitCooling-dedicated

    indoor unit

    Outdoor unit

    BS unit A BS unit B Final BS unit

    C/H SE

    LECT

    OR

    COOL/HEATSELECTOR

    COOL/HEATSELECTOR

    COOL/HEATSELECTOR

    C/H SE

    LECT

    OR

    C/H SE

    LECT

    OR

    TO IN/D UNIT TO OUT/D UNIT TO IN/D UNIT TO OUT/D UNIT TO IN/D UNIT TO OUT/D UNIT

    TO IN/D UNIT TO OUT/D UNIT

    F1 F2 F1F2

    F1F2

    F1F2

    F1F2

    branchSub-branching

    Cut out section

    Cup washer

    Ring-type crimp style terminal

    English 13

  • NOTES• Use ring-type crimp style terminal for connections to

    the power terminal block. (Refer to Fig. 6)Also, insulate the crimped area by attaching an insula-tion sleeve, etc.If these are not available, see the following section.(a)Wiring of different thicknesses cannot be connected

    to the power terminal block.(A loose connection could cause abnormal heat-ing.)

    (b)When connecting wire of the same diameter, make the connection as shown in the figure 7.

    • Use an appropriate screwdriver for tightening the ter-minal screw.Using a screwdriver that is too small could damage the screw head and prevent proper tightening.

    • Over tightening the terminal screw could damage the screw.Refer to the Table 4 for the terminal screw tightening torque.

    • When fastening the wire, use the included clamp 2)-1 so as not to apply tensile force to the wire connection and then securely fasten the wire. Also, after wiring is completed, organize the wiring so that the EL. COMPO. BOX lid does not pop up and then properly replace the EL. COMPO. BOX lid.Make sure no wires are pinched when replacing the EL. COMPO. BOX lid.Always use the wire through hole to protect the wires.

    • Do not pass the transmission wiring and power supply wiring through the same locations and outside of the unit keep them separated by at least 50mm.Not doing so could cause the transmission wiring to pick up electric noise (external noise) and result in a malfunction or breakdown.

    • After the wiring working is complete, use sealer (field supply) to seal closed the wire through hole.(Entry by small animals, etc., could cause a malfunction.)

    A1P

    F1 F2 F1 F2

    Transmission wiring from the indoor unit(To the TO IN/D UNIT F1, F2 terminals)

    Ground terminal Ground wire

    Wire

    Wire fitting

    Terminal block

    Power supply wiring(To the terminal block L1, L2 terminals)

    Wiring through hole (right)

    Wiring through hole (left)

    Transmission wiring from the outdoor unit(To the TO OUT/D UNIT F1, F2 terminals)

    Clamp 2)(Accessory)

    Clamp 2)(Accessory)

    Clamp 2)(Accessory)

    TO IN/D UNIT TO OUT/D UNIT

    Insulation sleeve

    Electric wireRing-type crimp style terminal

    Fig. 6

    Connect wires of the same gauge to both sides.

    Do not connect wires of the same gauge to one side.

    Do not connect wires of different gauges.

    Fig. 7

    Terminal screw sizeM3.5 (COOL/HEAT SELECTOR/transmission

    wiring terminal block (A1P))

    M4 (Power supply terminal block)M4 (Ground terminal)

    0.80-0.96

    1.18-1.441.52-1.86

    Tightening torque (N/m)

    Table 4

    14 English

  • 8. INITIAL SETTING• When the refrigerant piping and wire installation work is completed, make the following settings as

    required.1. Setting for when connecting the COOL/HEAT SELECTOR to the BS unit.

    〈Setting description〉Set the input signal from the COOL/HEAT SELECTOR (sold separately) to ON/OFF.

    〈Setting method〉Set the dip switches (DS1-1) on PCB (A1P) as shown at left before turning on the power to the BS unit.

    NOTESThis setting is read by the microcomputer when the BS unit power is turned on.• Be sure to make the setting before turning on the power.• Always close the EL. COMPO. BOX lid after making the setting.

    2. Setting when changing the “Automatic mode differential” in the Cooling/Heating Automatic Oper-ation Mode.

    〈Setting description〉• The “Automatic mode differential” can be changed within the range of 0˚C to 7˚C (0˚C at factory shipment).• For details regarding the “Automatic mode differential” and indoor unit operation, refer to the “Engineering

    data book”.

    〈Setting method〉The setting is made using the “Local Setting Mode” by the remote controller of indoor unit connected to the BS unit.For information regarding the setting method, refer to “Engineering data book”.The following table gives a list of the “MODE NO.,” “FIRST CODE NO.,” and “SECOND CODE NO.”

    NOTESThis setting is operated by the operation remote controller while the indoor unit power is turned on.• When the indoor unit, outdoor unit, and BS unit installation work is completed, confirm that it is safe even

    with the power turned on before proceeding with the work.

    9. TEST OPERATION

    (1) Check to make sure the EL. COMPO. BOX lid is closed.(2) Refer to the Installation Manual included with the outdoor unit and conduct a test run.

    • Clicking or humming sounds will continue for about 20 sec immediately after the power is turned on due to the start of automatic initialization operation (closing) of the solenoid valve, but this is not a problem.

    MODE NO. FIRST CODE NO. SECOND CODE NO. Automatic mode differential (˚C)

    12 (22) 4

    1 0 ← At factory shipment.

    2 1

    3 2

    4 3

    5 4

    6 5

    7 6

    8 7

    Turn on DS1-1.ON

    OFFDS1-1

    ON

    OFFDS1-2

    English 15

  • 10. WIRING DIAGRAM

    BS

    VQ

    100

    · 160

    · 25

    0P3Y

    W31

    796-

    1

    1.T

    HIS

    WIR

    ING

    DIA

    GR

    AM

    AP

    PLI

    ES

    TO

    TH

    E B

    S U

    NIT

    ON

    LY.

    2.

    : TE

    RM

    INA

    L S

    TR

    IP

    : C

    ON

    NE

    CT

    OR

    T

    ER

    MIN

    AL

    : F

    IELD

    WIR

    ING

    P

    RO

    TE

    CT

    IVE

    EA

    RT

    H3.

    WH

    EN

    US

    ING

    TH

    E C

    OO

    L/H

    EA

    T S

    ELE

    CT

    OR

    (O

    PT

    ION

    AL

    AC

    CE

    SS

    OR

    Y),

    C

    ON

    NE

    CT

    IT T

    O T

    HE

    TE

    RM

    INA

    LS A

    , B A

    ND

    C O

    N X

    2M.

    4.A

    S F

    OR

    WIR

    ING

    TO

    TH

    E IN

    /D U

    NIT

    (F

    1)•(

    F2)

    AN

    D O

    UT

    /D U

    NIT

    (F

    1)•(

    F2)

    ON

    X1M

    (A

    1P),

    RE

    FE

    R T

    O T

    HE

    INS

    TA

    LLA

    TIO

    N M

    AN

    UA

    L.5.

    SY

    MB

    OLS

    SH

    OW

    AS

    FO

    LLO

    WS

    (B

    LU: B

    LUE

    , RE

    D: R

    ED

    )6.

    US

    E C

    OP

    PE

    R C

    ON

    DU

    CT

    OR

    S O

    NLY

    .7.

    DIP

    SW

    ITC

    H (

    DS

    1, 2

    ) IN

    ITIA

    L S

    ET

    TIN

    GS

    AR

    E A

    S F

    OLL

    OW

    S.

    FO

    R U

    SIN

    G D

    IP S

    WIT

    CH

    (D

    S1,

    2),

    RE

    FE

    R T

    O IN

    ST

    ALL

    AT

    ION

    MA

    NU

    AL

    OR

    "S

    ER

    VIC

    E P

    RE

    CA

    UT

    ION

    " LA

    BE

    L O

    N E

    L. C

    OM

    PO

    . BO

    X.

    NO

    TE

    S)

    PR

    INT

    ED

    CIR

    CU

    IT B

    OA

    RD

    DIP

    SW

    ITC

    H

    FU

    SE

    (T

    , 3,1

    5A, 2

    50V

    )

    FLA

    SH

    ING

    LA

    MP

    (SE

    RV

    ICE

    MO

    NIT

    OR

    - G

    RE

    EN

    )

    SW

    ITC

    HIN

    G P

    OW

    ER

    SU

    PP

    LY (

    A1P

    )

    TE

    RM

    INA

    L S

    TR

    IP (

    PO

    WE

    R)

    TE

    RM

    INA

    L S

    TR

    IP (

    CO

    NT

    RO

    L)

    TE

    RM

    INA

    L S

    TR

    IP (

    C/H

    SE

    LEC

    TO

    R)

    ELE

    CT

    RO

    NIC

    EX

    PA

    NS

    ION

    VA

    LVE

    (S

    UB

    CO

    OL)

    ELE

    CT

    RO

    NIC

    EX

    PA

    NS

    ION

    VA

    LVE

    (S

    UB

    DIS

    CH

    AR

    GE

    )

    ELE

    CT

    RO

    NIC

    EX

    PA

    NS

    ION

    VA

    LVE

    (S

    UB

    SU

    CT

    ION

    )

    ELE

    CT

    RO

    NIC

    EX

    PA

    NS

    ION

    VA

    LVE

    (M

    AIN

    DIS

    CH

    AR

    GE

    )

    ELE

    CT

    RO

    NIC

    EX

    PA

    NS

    ION

    VA

    LVE

    (M

    AIN

    SU

    CT

    ION

    )

    NO

    ISE

    FIL

    TE

    R (

    FE

    RR

    ITE

    CO

    RE

    )

    CO

    NN

    EC

    TO

    R (

    WIR

    ING

    EX

    TE

    RN

    AL

    CO

    NT

    RO

    L

    AD

    AP

    TO

    R F

    OR

    OU

    TD

    OO

    R U

    NIT

    )

    A1P

    DS

    1,D

    S2

    HA

    P

    Y2E

    Y3E

    Y4E

    Y5E

    Z1C

    X2A

    X1M

    X1M

    (A

    1P)

    X2M

    Y1E

    F1U PS

    PO

    WE

    R S

    UP

    PLY

    220-

    240V

    50H

    z

    BS

    UN

    IT T

    OP

    NO

    TE

    )7.

    NO

    TE

    )3.

    CO

    NN

    EC

    TO

    R F

    OR

    OP

    TIO

    NA

    L P

    AR

    TS

    WIR

    ING

    DIA

    GR

    AM

    DS

    1D

    S2

    DS

    1D

    S2

    DS

    1D

    S2

    1 2

    3 4

    1 2

    3 4

    1 2

    3 4

    1 2

    3 4

    1 2

    3 4

    1 2

    3 4

    ON

    OF

    FO

    NO

    FF

    ON

    OF

    F

    BS

    VQ

    100P

    BS

    VQ

    160P

    BS

    VQ

    250P

    IND

    OO

    R U

    NIT

    OU

    TD

    OO

    R U

    NIT

    16 English

  • NOTES NOTES

  • 4PW46241-1B 09.2011

    Cop

    yrig

    ht 2

    009

    Dai

    kin

    1. SAFETY PRECAUTIONS2. BEFORE INSTALLATION2-1 CAUTION CONCERNING NEW REFRIGERANT SERIES2-2 PRECAUTIONS2-3 ACCESSORIES2-4 COMBINATION2-5 CHECK ITEM

    3. SELECTING INSTALLATION SITE4. PREPARATIONS BEFORE INSTALLATION5. BS UNIT INSTALLATION6. REFRIGERANT PIPING WORK6-1 PIPING MATERIAL SELECTION6-2 PROTECTION AGAINST CONTAMINATION WHEN INSTALLING PIPES6-3 PIPING CONNECTION WORK PRECAUTIONS6-4 PIPING SIZE SELECTION6-5 PIPING CONNECTION6-6 PIPING INSULATION

    7. ELECTRIC WIRING WORK7-1 GENERAL INSTRUCTIONS7-2 EXAMPLE FOR THE WHOLE SYSTEM7-3 POWER CIRCUIT, SAFETY DEVICE AND CABLE REQUIREMENTS7-4 WIRING EXAMPLE7-5 WIRING CONNECTIONS

    8. INITIAL SETTING9. TEST OPERATION10. WIRING DIAGRAM