3
Installation Videos: MY FireplaceBlower MyFireplaceBlower.com: Installation Instructions: Installer is responsible to check local codes and read all instructions prior to installation. Layout designed in U.S.A. © 2015 My Fireplace Blower Burlington, Wisconsin 1-800-466-4045 Drywall dust or other fragments may be present in your fireplace’s vent space, clean this area before you install the blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy. Instructions for Design Version - BK3 Fan Kit This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re- sponsibility to read all instructions and consult the Owner’s Installation Manual for your particular model number for Supplemental Information before starting installation. Blower operates on 120V/60Hz power. CLICK High Quality Aftermarket Fireplace Blowers & Fans 1-800-466-4045 Check the contents of the carton. Make sure nothing was damaged in shipment. Do NOT install a damaged blower kit! Blower Kit Parts Step 1: Turn Off Fireplace and allow it to cool down. Disconnect from 120V Power. Shut off the Gas supply. Remove Glass Doors. (If applicable: Figure: 1) Step 2: Remove the front refractory access panel by lifting up and angling out through the fireplace opening. (Figure: 2) Figure: 1 CLICK CLICK NOTE: Diagrams and Illustrations NOT to Scale Page 1 of 3 WARNING RISK OF FIRE AND ELECTRICAL SHOCK! TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER! When installed, make sure to contain any excess wire of the cord set; Preventing it from making contact with moving or hot objects. Description Qty. Fan - 3 Motor System Power Cord Harness ON/OFF Rocker Switch Hardware Installation Instructions (Downloadable) 1 1 1 1 1 3-Prong to 2-Prong Adapter 1 GLASS DOOR REMOVAL

Installation Instructions for BK3 Blower Fan Kit| BK3 ... · Instructions for Design Version - BK3 Fan Kit This Blower Kit is tested and safe when installed in accordance with these

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Installation Instructions for BK3 Blower Fan Kit| BK3 ... · Instructions for Design Version - BK3 Fan Kit This Blower Kit is tested and safe when installed in accordance with these

Installation Videos:

MYFireplaceBlower MyFireplaceBlower.com:

Installation Instructions:

Installer is responsible to check local codes and read all instructions prior to installation.Layout designed in U.S.A. © 2015

My Fireplace BlowerBurlington, Wisconsin

1-800-466-4045

Drywall dust or other fragments may be present in your fireplace’s vent space, clean this area before you install the blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy.

Instructions for Design Version - BK3 Fan Kit

This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re-sponsibility to read all instructions and consult the Owner’s Installation Manual for your particular model number for Supplemental Information before starting installation. Blower operates on 120V/60Hz power.

CLICK

High Quality Aftermarket Fireplace Blowers & Fans 1-800-466-4045

Check the contents of the carton. Make sure nothing was damaged in shipment. Do NOT install a damaged blower kit!

Blower Kit Parts

Step 1: Turn Off Fireplace and allow it to cool down. Disconnect from 120V Power. Shut off the Gas supply.

Remove Glass Doors. (If applicable: Figure: 1)

Step 2: Remove the front refractory accesspanel by lifting up and angling out through the fireplace opening. (Figure: 2)

Figure: 1

CLICK

CLICK

NOTE: Diagrams and Illustrations NOT to Scale

Page 1 of 3

WARNINGRISK OF FIRE AND ELECTRICAL SHOCK!

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER!When installed, make sure to contain any excess wire of the cord set; Preventing it from making contact with moving or hot objects.

Description Qty.Fan - 3 Motor System

Power Cord Harness ON/OFF Rocker Switch

HardwareInstallation Instructions (Downloadable)

111

11

3-Prong to 2-Prong Adapter 1 GLASS DOOR REMOVAL

Page 2: Installation Instructions for BK3 Blower Fan Kit| BK3 ... · Instructions for Design Version - BK3 Fan Kit This Blower Kit is tested and safe when installed in accordance with these

Step 3: Remove the control cover panel.

Remove the lower louver panel (ifinstalled) by gently pushing out thepanel from behind, down inside the mounting frame.

Remove the knockout plug fromthe lower louver panel.(Figure: 2)

Step 4: Place the fan assembly with theblades pointing towards the rear of the fireplace and in between the two leg stands. (Figure: 3 & 7)

Using 2 of the screws provided, fasten the upper flange of the blower bracket to the hearth pan.

Then fasten the end flanges to the leg stands with the remaining 4 screws.(Figure: 3)

NOTE: Keep wire assembly away from the fan blades.

CLICK

Installer is responsible to check local codes and read all instructions prior to installation.Layout designed in U.S.A. © 2015

NOTE: Diagrams and Illustrations NOT to Scale

Page 2 of 3My Fireplace Blower

Burlington, Wisconsin1-800-466-4045

MyFireplaceBlower.com:

ACCESSING THE LOWER COMPARTMENT

Figure: 2

Figure: 3

Exhaust Air to Outside

Room Airin Bottom

Heated Air out Top

FANS

Figure: 7

Page 3: Installation Instructions for BK3 Blower Fan Kit| BK3 ... · Instructions for Design Version - BK3 Fan Kit This Blower Kit is tested and safe when installed in accordance with these

MYFireplaceBlower

NOTE: Diagrams and Illustrations NOT to Scale

Page 3 of 3

Installations in Canada must conform to the current CAN/CGAB-419.1 and .2 Gas Installation Code and local regula-tions. When installing the blower fan kit, it must be electrically grounded in accordance with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.

Installations in the USA must conform to local codes, or in absence of local codes or the National Fuel Gas Code, ANSI Z223.1-1988. When installing the blower fan kit, it must be grounded in accordance with local codes, or in absence of local codes, with the National Electrical Code, ANSI/NFPA 70-1987.

My Fireplace Blower LLC produces and sells aftermarket fireplace blower kits; which require consultation of an Owner’s Installation Manual from the Manufacturer of a particular fireplace model number for in-stallation. During Installation of a fireplace blower kit or replacement blower, refer to the Owner’s Instal-lation Manual for your particular fireplace model to obtain supplemental information. My Fireplace Blower LLC is not responsible for any damage incurred during installation or resulting from installation of a fire-place blower kit, which was directed and/or conducted from the information within this document.

Installation Videos:

Installation Instructions:

CLICK

CLICK

CLICK

Installer is responsible to check local codes and read all instructions prior to installation.Layout designed in U.S.A. © 2015

My Fireplace BlowerBurlington, Wisconsin

1-800-466-4045

MyFireplaceBlower.com:

Step 5: Remove the 2 connectors from the ON/OFF rocker switch located on the wiring harness.(Figure: 4)

Insert the rocker switch into the lower louver panel with the switch lever pointing outward.

Connect the previously removed wire connectors onto rocker switch.

Insert the power plug into one of the available power receptacles.(Figure: 5)

Figure 6 – Wiring Diagram

WHITE

BLACK

GREENGround

Step 6: Reinstall the louver panel (if equipped) into the framed opening with the louvers pointing upward. Replace the cover back over the compartment opening.

Reinstall the front refractory panel.

Reinstall glass doors in reverse or-der shown in Figure 1.

To operate, turn the rocker switch to the ON position.

Figure: 5

Power Receptacle

Blower Supply Plug

Figure: 4

Figure: 6Figure 6 show the wiring diagram for this fan kit.