9
1 waclighting.com Phone (800) 526.2588 Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050 Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122 Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760 HARDWARE WARNING IMPORTANT: NEVER attempt any work without shutting off the electricity. - Read all instructions before installing. - System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations. - Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the fixture or room that you are working on. - Place the wall switch in the “OFF” position. CAUTION - All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this fixture. CAUTION When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only. AVERTISSEMENT IMPORTANT : Coupez l’électricité avant TOUTE manipulation. - Lisez toutes les instructions avant d’installer. - Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »). MISE EN GARDE - Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base. ADVERTENCIA IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara. - Sistema está disenado para ser instalado por un electricista calificado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO). PRECAUCIÓN - Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calificación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo. INSTALLATION INSTRUCTION 1 modernforms.com Phone (800) 526.2588 Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050 Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122 Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760 G0 Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. WS-W81612 816-Vanities & Wall Sconce :LUH&RQQHFWRU 4W\ SFV([WUD ($& 3 0RXQWLQJ 6FUHZ 4W\ ([WUD 03)6 [ 1LFNHO -XQFWLRQ %R[ 6FUHZ 4W\ ([WUD 03)& [ 1LFNHO &RQYHUVLRQ 3ODWH 4W\ SF 0%$%$ %UXVKHG $OXP $VVHPEO\6FUHZ 4W\ ([WUD 03)& [ 6WDLQOHVV VWHHO 0RXQWLQJ 5LQJ 4W\ SF 0%& 'ULYHU 4W\ SF /'0$8,63 A B C D E F G H $GMXVWDEOH 1XW 4W\ ([WUD 03)6 [ 1LFNHO I

INSTALLATION INSTRUCTION 816-Vanities & Wall Sconce 168 … · 2020-03-23 · SABRE- Vanities & Wall Sconces WS-W81625/WS-W81637. Modern Forms Pone 2.2 Fax 2.2 Headquarters/Eastern

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INSTALLATION INSTRUCTION 816-Vanities & Wall Sconce 168 … · 2020-03-23 · SABRE- Vanities & Wall Sconces WS-W81625/WS-W81637. Modern Forms Pone 2.2 Fax 2.2 Headquarters/Eastern

1WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting off the electricity.- Read all instructions before installing.- System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the fixture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this fixture. CAUTION When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista calificado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calificación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

Wire ConnectorQty: 3 pcs + 1 Extra

Junction Box ScrewQty: 2 pcs + 1 Extra

#8-32x1Zinc Plating

Mounting ScrewQty: 1 Extra5/32-32x1/2

BN

Plastic AnchorQty: 3 pcs + 1 Extra

Wood ScrewQty: 3 pcs + 1 Extra

Ø4x35

A1 B1 C1 D1 E1

PD-16818,PD-16824,PD-16830168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

Wire Connector Qty: 3 pcs+1 Extra

G0 Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

WS-W81612816-Vanities & Wall Sconce

A B C D E F G H I

Page 2: INSTALLATION INSTRUCTION 816-Vanities & Wall Sconce 168 … · 2020-03-23 · SABRE- Vanities & Wall Sconces WS-W81625/WS-W81637. Modern Forms Pone 2.2 Fax 2.2 Headquarters/Eastern

2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

PREPARATION 1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from fixture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the fixture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.

If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),

fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.

7. Insert the PC diffuser into the fixture shade.8. Secure the fixture onto mounting plate with mounting screws (C1).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

Plastic Anchor

Wire Connector

Wood Screw

Junction Box Screw

Mounting Screw

Fixture Shade

PC Diffuser

Mounting Plate

Junction Box

Glass(RPL-GLA-13114)

Shade(RPL-SHA-13114)

D1

A1

E1

B1

C1

FIG. 1

Ø7"

Back Plate Dimensions

Ø8 3/4"

Ø2 3/4"

Ø3 1/2"

PD-16818,PD-16824,PD-16830168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

Junction Box

Mounting Plate

Canopy

Stem

FixtureShade

PC Diffuser

Glass(RPL-GLA-13114)(RPL-GLA-13120)(RPL-GLA-13126)

Shade(RPL-SHA-16818)(RPL-SHA-16824)(RPL-SHA-16830)

Diffuser(RPL-DIF-13114)(RPL-DIF-13120)(RPL-DIF-13126)

PD-16818 4 3/4"

PD-16824 4 3/4"

PD-16830 4 3/4"

PD

-168

18 4

3/4

"

PD

-168

24 4

3/4

"

PD

-168

30 4

3/4

"

PD

-168

18

2 -1

/2"

PD

-168

24

2 -1

/2"

PD

-168

30

2 -1

/2"

G0 Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

Junction Box

Mounting Plate

Canopy

Stem

FixtureShade

PC Diffuser

Glass(RPL-GLA-13114)(RPL-GLA-13120)(RPL-GLA-13126)

Shade(RPL-SHA-16818)(RPL-SHA-16824)(RPL-SHA-16830)

Diffuser(RPL-DIF-13114)(RPL-DIF-13120)(RPL-DIF-13126)

PD-16818 2-1/2"

PD-16824 2-1/2"

PD-16830 2-1/2"

PD-16818 4 3/4"PD-16824 4 3/4"PD-16830 4 3/4"

3. Remove the mounting screw (C) from the fixture.

5. Choose number of rods suitable for your application.6. Thread the fixture wire through the rods and canopy.7. Connect the canopy, rods and lamp body. Make sure all are tightened.

8. Cut the extra wire. Connect the fixture’s input wires to junction box wires as shown in Fig.2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

9. Insert the PC diffuser into the fixture shade.

4. Secure the mounting plate to the junction box using junction Box screws(B).The side of the mounting back plate marked “GND” must face out.

MOUNTING THE FIXTURE (Fig. 1)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.

PREPARATION

CONNECTING THE WIRES (Fig. 2)

COMPLETING THE INSTALLATION (Fig. 1, 2)

10. Secure the fixture onto mounting plate with mounting Screws(C).11. For slope ceiling application, rotate wire at the top of the stem to ensure luminaries is aiming down.

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

WS-W81612816-Vanities & Wall Sconce

B

H

Adjustable Nut

C

Switch Box

Driver 2 7/8"L x1 3/8"W x1 1/8"H

Fixture

G

AMounting Plate

I

"x " "

Mounting Plate

FE

C

D

G

Adjustable Nut

FixtureBackplate

I

FIG.1 MOUNT ON SWITCH BOX FIG.3

FIG.2 MOUNT ON JUNCTION BOX FIG.5

Caulking

Junction Box

te, insert the plastic anchors (D1).ng sure that all wire connectors (A1) are secured.

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

House WiresBlack(Hot)

House WiresWhite (Neutral)

Fig. 2 Wiring

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 WiringFig.4 Wiring

Page 3: INSTALLATION INSTRUCTION 816-Vanities & Wall Sconce 168 … · 2020-03-23 · SABRE- Vanities & Wall Sconces WS-W81625/WS-W81637. Modern Forms Pone 2.2 Fax 2.2 Headquarters/Eastern

2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

PREPARATION 1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from fixture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the fixture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.

If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),

fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.

7. Insert the PC diffuser into the fixture shade.8. Secure the fixture onto mounting plate with mounting screws (C1).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

Plastic Anchor

Wire Connector

Wood Screw

Junction Box Screw

Mounting Screw

Fixture Shade

PC Diffuser

Mounting Plate

Junction Box

Glass(RPL-GLA-13114)

Shade(RPL-SHA-13114)

D1

A1

E1

B1

C1

FIG. 1

Ø7"

Back Plate Dimensions

Ø8 3/4"

Ø2 3/4"

Ø3 1/2"

PD-16818,PD-16824,PD-16830168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

Junction Box

Mounting Plate

Canopy

Stem

FixtureShade

PC Diffuser

Glass(RPL-GLA-13114)(RPL-GLA-13120)(RPL-GLA-13126)

Shade(RPL-SHA-16818)(RPL-SHA-16824)(RPL-SHA-16830)

Diffuser(RPL-DIF-13114)(RPL-DIF-13120)(RPL-DIF-13126)

PD-16818 4 3/4"

PD-16824 4 3/4"

PD-16830 4 3/4"

PD

-168

18 4

3/4

"

PD

-168

24 4

3/4

"

PD

-168

30 4

3/4

"

PD

-168

18

2 -1

/2"

PD

-168

24

2 -1

/2"

PD

-168

30

2 -1

/2"

G0 Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

Junction Box

Mounting Plate

Canopy

Stem

FixtureShade

PC Diffuser

Glass(RPL-GLA-13114)(RPL-GLA-13120)(RPL-GLA-13126)

Shade(RPL-SHA-16818)(RPL-SHA-16824)(RPL-SHA-16830)

Diffuser(RPL-DIF-13114)(RPL-DIF-13120)(RPL-DIF-13126)

PD-16818 2-1/2"

PD-16824 2-1/2"

PD-16830 2-1/2"

PD-16818 4 3/4"PD-16824 4 3/4"PD-16830 4 3/4"

3. Remove the mounting screw (C) from the fixture.

5. Choose number of rods suitable for your application.6. Thread the fixture wire through the rods and canopy.7. Connect the canopy, rods and lamp body. Make sure all are tightened.

8. Cut the extra wire. Connect the fixture’s input wires to junction box wires as shown in Fig.2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

9. Insert the PC diffuser into the fixture shade.

4. Secure the mounting plate to the junction box using junction Box screws(B).The side of the mounting back plate marked “GND” must face out.

MOUNTING THE FIXTURE (Fig. 1)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.

PREPARATION

CONNECTING THE WIRES (Fig. 2)

COMPLETING THE INSTALLATION (Fig. 1, 2)

10. Secure the fixture onto mounting plate with mounting Screws(C).11. For slope ceiling application, rotate wire at the top of the stem to ensure luminaries is aiming down.

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

WS-W81612816-Vanities & Wall Sconce

3

3. Remove the mounting screw (B) from the fixture.

5. Secure the mounting plate to the switch box using the junction box screw (C) The side of the mounting plate marked “GND” must face out.

* Required Driver to be recessed within the junction box.

6. The back plate location for this fixture is adjustable. First loosen both adjust nuts(I) by screw driver. Second adjust the back plate to your desired location. Third, pull and tighten the electrical wire. Forth, secure the back plate by screwing both adjust nuts clockwise. 7. Place the fixture over the mounting plate, and secure it with mounting screw (B) and Silicon Gasket (H).8. To prevent moisture from entering the fixture and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the dotted line enclosed area as shown in Fig 3.

4. Connect the driver (G) input wire to junction box wires as shown in Fig. 3, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare cooper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the switch box.

3. Remove the mounting screw (B) from the fixture.

5. Secure the mounting ring(D) to the switch box using the junction box screw (C). Make sure the two holes (Spacing 2-3/4”) are horizontal as shown in Fig. 2. The side of the mounting plate marked “GND” must face out.

* Required Driver to be recessed within the junction box.

6. Secure the mounting plate and conversion plate (E) to the mounting ring with assembly screw (F).7. The back plate location for this fixture is adjustable. First loosen both adjust nuts(I) by screw driver. Second adjust the back plate to your desired location. Third, pull and tighten the electrical wire. Forth, secure the back plate by screwing both adjust nuts clockwise. Lastly,

4. Connect the driver (G) input wire to junction box wires as shown in Fig. 4, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare cooper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the switch box.

8 Place the fixture over the mounting plate, and secure it with mounting screw (B) and Silicon Gasket (H).9. To prevent moisture from entering the fixture and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the dotted line enclosed area as shown in Fig 3.

10. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig.5.

MOUNT ON 2”X4”SWITCH BOX (Fig. 1)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

PREPARATION

OR

MOUNT ON 4”x 4”JUNCTION BOX (Fig. 2)

Ø4"

1 3/4"

1 3/8" 4 1/4"

2 3/8"

1 3/8" 1 5/8"

5"

4 1/2"

1 3/8"1 5/8"

Mounting Ring Dimensions7MBC101501

Conversion Plate4MBA121109BA

Back Plate Dimensions7MBC106002

Page 4: INSTALLATION INSTRUCTION 816-Vanities & Wall Sconce 168 … · 2020-03-23 · SABRE- Vanities & Wall Sconces WS-W81625/WS-W81637. Modern Forms Pone 2.2 Fax 2.2 Headquarters/Eastern

Modern Formswww.modernforms.comPhone (800) 526.2588 • Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive • Port Washington, NY 11050Phone (516) 515.5000 • Fax (516) 515.5050

Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761Phone (800) 526.2588 • Fax (800) 526.2585

Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2016 1

INSTALLATION INSTRUCTIONSABRE- Vanities & Wall SconcesWS-W81619

HARDWARE

A1 B1 C1 D1 E1 F1 G1

Wire ConnectorQty: 3PCS+1Extra7EAC112201P3

Junction Box ScrewQty: 2 pcs + 1 Extra7MPF0415C2#8-32x9/16Stainless Steel

Mounting ScrewQty: 1pc Extra7MPF0412S35/32”-32x1/2Stainless Steel

Waterproof WasherQty: 1pc Extra7TGD060301CL

Conversion PlateQty: 1pc4MBA151110BA

Mounting RingQty: 1pc7MBC101501

Assembly ScrewQty: 2pc + 1Extra7MPF0808C1#8-32x5/16Nickel Plating

WARNINGIMPORTANT: NEVER attempt any work without shutting off the electricity.- Read all instructions before installing.- System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the fixture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this fixture. CAUTION When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista calificado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calificación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

Page 5: INSTALLATION INSTRUCTION 816-Vanities & Wall Sconce 168 … · 2020-03-23 · SABRE- Vanities & Wall Sconces WS-W81625/WS-W81637. Modern Forms Pone 2.2 Fax 2.2 Headquarters/Eastern

Modern Formswww.modernforms.comPhone (800) 526.2588 • Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive • Port Washington, NY 11050Phone (516) 515.5000 • Fax (516) 515.5050

Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761Phone (800) 526.2588 • Fax (800) 526.2585

Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2016 2

Junction BoxFIG. 2 MOUNT ON JUNCTION BOX

C1

D1

B1

F1

E1

G1

A1

B1

Back Plate Dimensions Mounting Ring Dimensions

Mounting Screw

Waterproof Washer

SwitchBox

Driver

Mounting Ring

Junction Box Screw

Mounting Plate

Assembly Screw

Conversion Plate

Input Wires

Wire Connector

Mounting Plate

Junction Box Screw

5 1/2”

2 3/8”1 3/4”

1 3/8”

Ø3 1/4”

Ø4”

Ø2 3/4”

Driver

Fixture

FIG. 1 MOUNT ON SWITCH

INSTALLATION INSTRUCTIONSABRE- Vanities & Wall SconcesWS-W81619

Page 6: INSTALLATION INSTRUCTION 816-Vanities & Wall Sconce 168 … · 2020-03-23 · SABRE- Vanities & Wall Sconces WS-W81625/WS-W81637. Modern Forms Pone 2.2 Fax 2.2 Headquarters/Eastern

Modern Formswww.modernforms.comPhone (800) 526.2588 • Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive • Port Washington, NY 11050Phone (516) 515.5000 • Fax (516) 515.5050

Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761Phone (800) 526.2588 • Fax (800) 526.2585

Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2016 3

Junction Box

Caulking

Fig. 4 Sealing

PREPARATION 1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

INSTALLATIONMOUNT ON SWITCH BOX (Fig. 1) 3. Remove the mounting screw (C1) and waterproof washer (D1) from the fixture.4. Connect the driver input/output wire to supply wires as shown in Fig. 3, making sure that all wire connectors (A1) are secured. If your outlet

box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the switch box.

5. Secure the mounting plate to the switch box using the junction box screw (B1). The side of the mounting plate marked “GND” must face out.6. Place the fixture over the mounting back plate, and secure it with mounting screw (C1) and water proof washer (D1).7. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the

outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig. 4.

OR

MOUNT ON JUNCTION BOX (Fig. 2)3. Remove the mounting screw (C1) and waterproof washer (D1) from the fixture.4. Connect the driver input/output wire to supply wires as shown in Fig. 3, making sure that all wire connectors (A1) are secured. If your outlet

box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

5. Secure the mounting ring (D1) to the junction box using the junction box screw (B1). Make sure the two holes (spacing 2-3/4”) are horizontal as shown in Fig 2. The side of the mounting plate marked “GND” must face out.

6. Place the mounting plate and the conversion plate (E1) onto the mounting ring (F1), secure them with assembly screw (G1).7. Place the fixture over the mounting back plate, and secure it with mounting screw (C1) and water proof washer (D1).8. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the

outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig. 4.

INSTALLATION INSTRUCTIONSABRE- Vanities & Wall SconcesWS-W81619

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

Page 7: INSTALLATION INSTRUCTION 816-Vanities & Wall Sconce 168 … · 2020-03-23 · SABRE- Vanities & Wall Sconces WS-W81625/WS-W81637. Modern Forms Pone 2.2 Fax 2.2 Headquarters/Eastern

Modern Formswww.modernforms.comPhone (800) 526.2588 • Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive • Port Washington, NY 11050Phone (516) 515.5000 • Fax (516) 515.5050

Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761Phone (800) 526.2588 • Fax (800) 526.2585

Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2016 4

INSTALLATION INSTRUCTIONSABRE- Vanities & Wall SconcesWS-W81625/WS-W81637

HARDWARE

A1 B1 C1 D1 E1 F1 G1

Wire ConnectorQty: 3PCS+1Extra7EAC112201P3

Junction Box ScrewQty: 2 pcs + 1 Extra7MPF0415C2#8-32x9/16Stainless Steel

Mounting ScrewQty: 1pc Extra7MPF0412S35/32”-32x1/2Stainless Steel

Waterproof WasherQty: 1pc Extra7TGD060301CL

Conversion PlateQty: 1pc4MBA151110BA

Mounting RingQty: 1pc7MBC101501

Assembly ScrewQty: 2pc + 1Extra7MPF0808C1#8-32x5/16Nickel Plating

WARNINGIMPORTANT: NEVER attempt any work without shutting off the electricity.- Read all instructions before installing.- System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the fixture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this fixture. CAUTION When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista calificado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calificación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

Page 8: INSTALLATION INSTRUCTION 816-Vanities & Wall Sconce 168 … · 2020-03-23 · SABRE- Vanities & Wall Sconces WS-W81625/WS-W81637. Modern Forms Pone 2.2 Fax 2.2 Headquarters/Eastern

Modern Formswww.modernforms.comPhone (800) 526.2588 • Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive • Port Washington, NY 11050Phone (516) 515.5000 • Fax (516) 515.5050

Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761Phone (800) 526.2588 • Fax (800) 526.2585

Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2016 5

Assembly Screw

Junction BoxFIG. 2 MOUNT ON JUNCTION BOX

C1

D1

B1

F1

E1

G1

A1

B1

Back Plate Dimensions Mounting Ring Dimensions

Mounting Screw

Waterproof Washer

SwitchBox

Driver

Mounting Ring

Junction Box Screw

Mounting Plate

Conversion Plate

Input Wires

Wire Connector

Mounting Plate

Junction Box Screw

5 7/8”

2 1/2” 1 3/4”

1 3/8”

Ø3 1/4”

Ø4”

Ø2 3/4”

Driver

Fixture

FIG. 1 MOUNT ON SWITCH

INSTALLATION INSTRUCTIONSABRE- Vanities & Wall SconcesWS-W81625/WS-W81637

Page 9: INSTALLATION INSTRUCTION 816-Vanities & Wall Sconce 168 … · 2020-03-23 · SABRE- Vanities & Wall Sconces WS-W81625/WS-W81637. Modern Forms Pone 2.2 Fax 2.2 Headquarters/Eastern

Modern Formswww.modernforms.comPhone (800) 526.2588 • Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive • Port Washington, NY 11050Phone (516) 515.5000 • Fax (516) 515.5050

Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761Phone (800) 526.2588 • Fax (800) 526.2585

Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2016 6

Junction Box

Caulking

Fig. 4 Sealing

PREPARATION 1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

INSTALLATIONMOUNT ON SWITCH BOX (Fig. 1) 3. Remove the mounting screw (C1) and waterproof washer (D1) from the fixture.4. Connect the driver input/output wire to supply wires as shown in Fig. 3, making sure that all wire connectors (A1) are secured. If your outlet

box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the switch box.

5. Secure the mounting plate to the switch box using the junction box screw (B1). The side of the mounting plate marked “GND” must face out.6. Place the fixture over the mounting back plate, and secure it with mounting screw (C1) and water proof washer (D1).7. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the

outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig. 4.

OR

MOUNT ON JUNCTION BOX (Fig. 2)3. Remove the mounting screw (C1) and waterproof washer (D1) from the fixture.4. Connect the driver input/output wire to supply wires as shown in Fig. 3, making sure that all wire connectors (A1) are secured. If your outlet

box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

5. Secure the mounting ring (D1) to the junction box using the junction box screw (B1). Make sure the two holes (spacing 2-3/4”) are horizontal as shown in Fig 2. The side of the mounting plate marked “GND” must face out.

6. Place the mounting plate and the conversion plate (E1) onto the mounting ring (F1), secure them with assembly screw (G1).7. Place the fixture over the mounting back plate, and secure it with mounting screw (C1) and water proof washer (D1).8. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the

outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig. 4.

INSTALLATION INSTRUCTIONSabre- Vanities & Wall SconcesWS-W81625/WS-W81637

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring