Upload
others
View
15
Download
0
Embed Size (px)
Citation preview
P
P
P
P
P
P
A266.1 (ex. a):
© Danfoss | 2018.03 VI.KT.Z5.00 | 1
ECL Comfort 210 / 296 / 310, A266 (code no. 087H3800)
Installation Guide
A266.1 (ex. b):
A266.1 (ex. c):
S4
P1
S1
Dan
foss
87H
2144
.14ECL 210 / 296 / 310
M1
S3
S5
P2M2
S6
A1
S2
S7
A266.2 (ex. a):
Installation Guide, ECL Comfort 210 / 296 / 310, A266
2 | © Danfoss | 2018.03 VI.KT.Z5.00
A266.9 (ex. a):
A266.10 (ex. a):
Installation Guide, ECL Comfort 210 / 296 / 310, A266
© Danfoss | 2018.03 | 3VI.KT.Z5.00
ECL Comfort 210 / 296 / 310:230 V a.c.
4 (2) A / 230 V a.c.
0,2 A / 230 V a.c.
230 V a.c. , A266.1 / A266.2 / A266.9 / A266.10
230 V a.c. , A266.1 / A266.2 / A266.9 / A266.10
Installation Guide, ECL Comfort 210 / 296 / 310, A266
4 | © Danfoss | 2018.03 VI.KT.Z5.00
230 V a.c. / 24 V a.c. , safety thermostat
1-step closing
Dan
foss
87H
2105
.10ECL 210 / 310
M1
230 V a.c. / 24 V a.c. , safety thermostat
1-step closing
Dan
foss
87H
2106
.10ECL 210 / 310
M2
230 V a.c. / 24 V a.c. , safety thermostat1-step closing
Dan
foss
87H
2107
.10ECL 210 / 310
M1
230 V a.c. / 24 V a.c. , safety thermostat1-step closing
ECL 210 / 310
Dan
foss
87H
2108
.10
M2
Installation Guide, ECL Comfort 210 / 296 / 310, A266
© Danfoss | 2018.03 | 5VI.KT.Z5.00
230 V a.c. / 24 V a.c. , safety thermostat
2-step closing
ECL 210 / 310
Dan
foss
87H
2109
.10
M1
230 V a.c. / 24 V a.c. , safety thermostat2-step closing
ECL 210 / 310
Dan
foss
87H
2110
.10
M2
ECL Comfort 210 / 296 / 310:24 V a.c.
4 (2) A / 24 V a.c.
1 A / 24 V a.c.
Installation Guide, ECL Comfort 210 / 296 / 310, A266
6 | © Danfoss | 2018.03 VI.KT.Z5.00
24 V a.c. (A266.1 / A266.2 / A266.9 / A266.10)
24 V a.c. (A266.1 / A266.2 / A266.9 / A266.10)
Installation Guide, ECL Comfort 210 / 296 / 310, A266
© Danfoss | 2018.03 | 7VI.KT.Z5.00
Pt 1000 (1000 Ω / 0 °C)
87H
1487
.11
Dan
foss
30
3231
2928 S2
S1
B
+
EC
L 48
5
ECL Comfort 210 / 296 / 310
PE
N
L230 V a.c.
S2 S1
30
3231
2928 S2
S1
B
+
EC
L 48
5
ECL Comfort 210 / 296 / 310
PE
N
L230 V a.c.
S2 S1
A266.1 / A266.2 / A266.9 / A266.10
A266.1 / A266.2 / A266.10
S7
87H
1098
.12
Dan
foss
S8
S7
S6
S5
S4
S3
S2
S1
ECL 210 / 296
3029282726252423222120
S8
S7
S6
S5
S4
S3
S2
S1
S9
S10
METER
ECL 310
Installation Guide, ECL Comfort 210 / 296 / 310, A266
8 | © Danfoss | 2018.03 VI.KT.Z5.00
A266.1 / A266.2 / A266.10
S7
A / B ?
A: B:
A:
87H
1459
.11
Dan
foss
(l / m³) (kWh / MWh)
S8
S7
S6
S5
S4
S3
S2
S1
ECL 210 / 296
3029282726252423222120
S8
S7
S6
S5
S4
S3
S2
S1
S9
S10
ECL 310
31 + +
4,7 K Ω0,5 W
B:
87H
1460
.11
Dan
foss
S8
S7
S6
S5
S4
S3
S2
S1
ECL 210 / 296
3029282726252423222120
S8
S7
S6
S5
S4
S3
S2
S1
S9
S10
ECL 310
31 + +
(l / m³) (kWh / MWh)
R
V+
Installation Guide, ECL Comfort 210 / 296 / 310, A266
© Danfoss | 2018.03 | 9VI.KT.Z5.00
A266.2 / A266.9 / A266.10S8
A266.9
V d.c. = 12 - 24 V d.c.
Installation Guide, ECL Comfort 210 / 296 / 310, A266
10 | © Danfoss | 2018.03 VI.KT.Z5.00
A266.9
V d.c. = 12 - 24 V d.c.
ECA 30 / 31
30
54321
ECA 30 / 31
ESM-10
(3)(2)(1)(4)
87H
1254
.12
Dan
foss
363534333231
2928272625 S5
S4
S3
S2
S1
S.Gnd
A
B
A
B
+
Mod
bus
EC
L 48
5
ECL 210 / 296 / 310
54321
ECA 30 / 31
ESM-10
(3)(2)(1)(4)
Installation Guide, ECL Comfort 210 / 296 / 310, A266
© Danfoss | 2018.03 | 11VI.KT.Z5.00
Master / slave
Dan
foss
87H
2052
.11
A
AB
BA
AB
B
Modbus
ECL 210 / 296 / 310
Dan
foss
87H
2060
.11
A
A
B
B
M-bus
ECL 296 / 310
Dan
foss
87H
2061
.11
A
A
B
B
Installation Guide, ECL Comfort 210 / 296 / 310, A266
12 | © Danfoss | 2018.03 VI.KT.Z5.00
M-bus
30 87H
1308
.11
Dan
foss
363534333231
29 S1
S.Gnd
A
B
A
B
+
ECL 296 / 310
3837
M-b
us
METERMETER
Installation Guide, ECL Comfort 210 / 296 / 310, A266
© Danfoss | 2018.03 | 13VI.KT.Z5.00
Pt 1000 (IEC 751B, 1000 Ω / 0 °C)
-50
800
900
1000
1100
1200
1300
1400
1500
1600
-25 0 25 50 75 100 125 150°C
Ω
Ω
803843 882922961
1000103910781117115511941232127113091347138514231461149815351573
°C
-50 -40 -30-20-10
0102030405060708090
100110120130140150
120
110
100
90
80
70
60
50
40
30
20
10
-30 -20 -10 0 10 20
2.2 2.6 3.0 3.41.8
1.4
1.0
0.6
0.2
Installation Guide, ECL Comfort 210 / 296 / 310, A266
14 | © Danfoss | 2018.03 VI.KT.Z5.00
ECA 30
Installation Guide, ECL Comfort 210 / 296 / 310, A266
© Danfoss | 2018.03 | 15VI.KT.Z5.00
16 | © Danfoss | DHS-SMT/DK | 2018.03 VI.KT.Z5.00
? ECL Comfort 210 / 296 / 310, A266: www.heating.danfoss.com *087H9002**VIKTZ500*
Installation Guide, ECL Comfort 210 / 296 / 310, A266